safety switches & enclosed circuit breakers cutler...
TRANSCRIPT
Safety Switches & Enclosed Circuit BreakersSafety Switches
Cutler-HammerJanuary 2001
Vol. 1, Ref. No. [0230]
Options and AccessoriesTable 8-1. Safety Switches — Accessories
Description
Neutral Kits/Ground Kits30ADG60 - 100A DG200A DG, DH (NEMA 1, 3R Enclosures)30-60A DH100A DH200A DH (NEMA 4X, 12 Enclosures)400A DG, DH600A DG, DH400 - 600A Fusible DT, 800-1200A DH30-100ADT200A DT400A Non-Fusible DT600 Non-Fusible DT
Ground Lug Kits30 - 100A DG30-100ADH, DT®200A DG, DH, DT400 - 600A DG, 400-1 200A DH, 400 - 800A DT
Control Pole Kit400 - 600A DG, 30-1 200A DH, 30 - 800A DT
Auxiliary Contact KitsAll Switches (except 30-100A DG) 1NO/1NCAll Switches (except 30-100A DG) 2NO/2NC
Copper Lug Kits30A DH, DT (order one kit for 3 poles)60A DH, DT (order one kit for 3 poles)100A DH, DT (order one kit for 3 poles)200A DH (order one kit for 3 poles)400A DG, DH (order one kit for each pole)600A DG, DH (order one kit for each pole)
Crimp Lug Pad Kit400 - 600A DG, DH (order one kit for 3 poles)800A DH (order one kit for each pole)400 - 800A Neutral DG, DH (order one kit per switch)
Fuse Puller Kits30 - 60A DH (order one kit for 3 poles)30 - 60A DH (4 pole switch only)100A DH (order one kit for 3 poles)200A DH (order one kit for 3 poles)
"J" Fuse Adapter Kits60A 240V DH (order one kit for 3 poles)60A 600V DH (order one kit for 3 poles)400A 600V DT (order one kit for 6 poles)600A 240-600V DH only (order one kit for each pole)
"R" Fuse Adapter Kits (order one kit for 3 poles)30A DG100A DG30A240VDH, DT30A 600V DH, DT, 60A 240V DH, DT, 60A DG60A 600V DH, DT100A240-600VDH, DT200A 240 - 600V DH, DT, 200A DG400A 240 - 600V DH, 240V DT, 400A DG600A 240 - 600V DH, 240V DT, 600A DG
"T" Fuse Adapter Kits200A 240V DH (order one kit for 3 poles)200A 600V DH (order one kit for 3 poles)400A 240V DG, DH (order one kit for each pole)400A 600V DH (order one kit for each pole)600A 240V DG, DH (order one kit for each pole)600A 600V DH (order one kit for each pole)800A 240V DH (order one kit for each pole)800A 600V DH (order one kit for each pole)
Hookstick Handle
Auxiliary Contacts for30A - 40A 3-pole Rotary Switches (1 NO) ®60A-100A3-pole Rotary Switches (1NO)®30A - 40A 4-pole Rotary Switches (1 NO) ®
CatalogNumber
DG030NBDG100NBDG200NKDH030NKDH100NKDH200NKDS400NKDS600NKDS800NKDT100NKDT200NKDT400NKDT600NK
DG030GBDS100GKDS200GKDS468GK
DS16CP
DS200EK1DS200EK2
DS16CLDS26CLDS36CLDS46CLDS56CLDS66CL
DS56CKDS76CKDS800CNK
DS30FPDS60FPDS100FPDS200FP
DS22JKDS26JKDT400JKDS600JK
DG030RBDG100RBDS12FKDS16FKDS26FKDS36FKDS46FKDS56FKDS66FK
DS426TKDS466TKDS526TKDS566TKDS626TKDS666TKDS726TKDS766TK
DH800HSH
CRAC3CWAC3CRAC4
PriceU.S.S
44.0088.00
129.0059.50
124.00142.00243.00258.00550.0077.50
135.00198.00250.00
16.1016.1030.00
171.00
148.00
203.00242.00
29.0036.5059.00
201.00249.00290.00
332.00149.00431.00
19.5027.0035.7584.00
18.4018.40
389.00135.00
17.1033.2517.1017.1017.1033.2549.5084.0084.00
191.00211.0065.0096.00
105.00109.00113.00132.00
129.00
29.2529.2529.25
DH030NK DS200GK
DS16CP DS200EK1
DS36CL DS56CK
DS30FP DS26JK
DS12FK DS426TK
® Single-pole, double throw, single-break snap action contactsrated at 6A, 250V maximum.
® Ground bar kit is not listed on device publications.
Discount Symbol 22-CD
E:T*M For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E
Safety Switches & Enclosed Circuit BreakersSafety SwitchesHeavy Duty Double Throw, Fusible, Non-Fusible
Cutler-HammerJanuary 2001
Vol. 1,Ref. No. [0250]
240V AC Heavy Duty Double Throw,
Fusible, Non-Fusible
Specifications
• 30 through 800 amperes,n Horsepower rated.• Suitable for service entrance use
with neutral or ground lug kitinstalled.
• Suitable for use as a manuallyoperated switch per NEC article 702.
•i Fusible and non-fusible.• UL Listed File No. E5239.• For factory modifications refer to
Pages 8-6 through 8-9.
Table 8-41. Fusible
A, A, A,
A, A. A. iy°N
>ON
b© OFF Two Sources\ I
KON
ba OFF Two Loads
fell' ON
DT323FRK Figure 8-8. Typical Fusible Double ThrowSchematic Diagram
AmpereRatingMainandStandby
FuseClassProvision
Maximum Horsepower Ratingswith Time Delay Fuses
1 -Phase AC
240V 480V 600V
3-Phase AC
240V 480V I 600V
DC250V
NEMA 1 EnclosureIndoor
Catalog Number Price U.S. $
NEMA 3R EnclosureRainproof
Catalog Number Price U.S. $
2-Pole — 240V AC — 250V DC
200 H 15 — — 40 DT224FGK 2,635. DT224FRK 3,660.
3-Pole — 240V AC — 250V DC
3060100200400600
HHHHHT
3101515 —
7-1/215306012575
—
51020405050
DT321FGKDT322FGKDT323FGKDT324FGKDT325FGKDT326FGK
760.1,385.2,255.3,420.8,280.8,710.
DT321FRKDT322FRKDT323FRKDT324FRKDT325FRKDT326FRK
1,000.1,830.2,605.4,445.9,360.
10,350.
Table 8-42. Non-Fusible
AmpereRatingMainandStandby
Maximum Horsepower Ratings
1 -Phase AC
240V 480V 600V
3-Phase AC
240V 480V 600V
DC250V
NEMA 1 EnclosureIndoor
Catalog Number Price U.S. $
NEMA 3R EnclosureRainproof
Catalog Number Price U.S. $
Non-Fusible 2-Pole — 240V AC — 250V DC
3060100200400600
3102015
— —
——
—510204050
DT221UGKDT222UGKDT223UGKDT224UGKDT225UGKDT226UGK
417.665.955.
1,265.3,655.6,160.
®®®DT224URKDT225URK®
1,650.5,620.
Non-Fusible 3-Pole — 240V AC — 250V DC
3060100200400600800
3102015
——
10204060125125125
— —
5102040505050
DT321UGKDT322UGKDT323UGKDT324UGKDT325UGKDT326UGKDT327UGK®®
485.830.
1,225.1,815.5,110.6,910.
10,420.
®®DT323URKDT324URK®®®
1,320.2,300.
® WARNING! Switch is not approved for service entrance.® Field installable neutral kit is not available. If a neutral is required, order the catalog number shown in the table with "—N" suffix.® Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product.
Discount Symbol 22-CD
F;T« For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E
January 2001Vol. 1,Ref. No. [0251]
Safety Switches & Enclosed Circuit BreakersSafety Switches
Heavy Duty Double Throw, Fusible, Non-Fusible
600V AC Heavy Duty Double Throw, Fusible, Non-FusibleTable 8-43. Fusible
AmpereRatingMainandStandby
FuseClassProvision
Maximum Horsepower Ratingswith Time Delay Fuses
1 -Phase AC
480V 600V
3-Phase AC
480V 600V
DC
250V
NEMA1EnclosureIndoor
CatalogNumber
PriceU.S. S
NEMA3REnclosureRainproof
CatalogNumber
PriceU.S.S
NEMA 12EnclosureIndustrial Dust-tight
CatalogNumber
PriceU.S.S
NEMA 4XEnclosureCorrosion ResistantStainless Steel
CatalogNumber
PriceU.S.S
3-Pole — 600V AC — 250V DC
3060100200400
HHHHT
7-1/2203050—
10254050—
153060125250
205075150350
——4050
DT361FGKDT362FGKDT363FGKDT364FGKDT365FGK
1,440.1,520.2,585.4,000.8,420.
®©DT363FRKDT364FRKDT365FRK
——
3,215.5,180.9,520.
®®®®®
—————
DT361FWKDT362FWKDT363FWKDT364FWKDT365FWK
3,150.8,330.9,430.
11,620.18,880.
® Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product.
Table 8-44. Non-Fusible
AmpereRatingMainandStandby
Maximum Horsepower Ratings
1 -Phase AC
480V 600V
3-Phase AC
480V 600V
DC
250V
NEMA 1 EnclosureIndoor
CatalogNumber
PriceU.S. $
NEMA 3R EnclosureRainproof
CatalogNumber
PriceU.S.S
NEMA 12 EnclosureIndustrial Dust-tight
CatalogNumber
PriceU.S.S
NEMA 4X EnclosureCorrosion ResistantStainless Steel
CatalogNumber
PriceU.S.S
2-Pole — 600V AC — 250V DC3060100200400600
7-1/2204050—
—
10255050—
—
—————
—
—————
—
51020405050
DT261UGKDT262UGKDT263UGKDT264UGK®DT265UGKDT266UGK
500.715.
1,070.1,475.4,590.6,820.
®®®DT264URK®DT265URKDT266URK
———
3,545.7,980.9,950.
—————
—
—————
—
_
————
—
—————
—
3-Pole — 600V AC — 250V DC
3060100200400600800800
7-1/2203050————
10255050————
205075125250250250250
2050100150350350350350
510204050505050
DT361UGKDT362UGKDT363UGKDT364UGKDT365UGKDT366UGKDT367UGK@®DT367UGK-N
535.810.
1,325.1,945.5,210.7,640.
11,660.12,560.
DT361URKDT362URKDT363URKDT364URKDT365URKDT366URKDT367URK®®DT367URK-N
985.1,360.2,300.4,200.8,410.
10,900.12,880.13,780.
DT361UDK®DT362UDK®DT363UDK®DT364UDK®DT365UDK®®®®
1,055.2,240.2,370.4,355.8,630.
———
DT361UWKDT362UWKDT363UWKDT364UWKDT365UWK®®®
2,070.3,805.5,770.6,960.
15,150.———
4-Poie — 600V AC — 250V DC ®
3060100200400600800
204050———
—
25505050——
—
205075125250250250
3060100150350350350
5102040505050
®®®DT464UGKDT465UGKDT466UGKDT467UGK
———
3,380.7,750.
11,200.28,990.
DT461URKDT462URKDT463URKDT464URKDT465URKDT466URKDT467URK
2,440.2,610.3,760.5,970.
10,500.12,920.37,660.
®®®©©®®
——————
—
®®©®©©©
——————
—
6-Pole — 600V AC — 250V DC ®
3060100
7-1/22030
2060100
DT661URKDT662URKDT663URK
3,855.4,870.7,320.
® NEMA 12 enclosures (30 - 200 amperes) can be field modified to meet NEMA 3R rainproof requirements when a factory provided drain hole is opened® WARNING! Switch is not approved for service entrance.® Rated 600V DC, 50 hp in addition to ratings shown in table.© Also available in 240V AC catalog number DT325UDK.® Field installable neutral kit is not available. If a neutral is required, order the catalog number shown in the table with "—N" suffix.® Contact the Safety Switch Flex Center (1-888-329-9272) for availability of this product.
Discount Symbol 22-CD
CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog F:T*N