safety federal signal products

11

Upload: arthur-chavarria

Post on 28-Apr-2015

112 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Safety Federal Signal Products
Page 2: Safety Federal Signal Products

Hot Products

27XL· 24VDC, 120VAC and 240VAC· Four lens colors· Flashing or steady-burn· 60,000 hour LED· 3/4-inch pendant mount

standard; other options available· Dome guard optional· Type 4X, IP66 enclosure· Marine Listed· UL and cUL Listed for Class 1,

Division 1

225XL· 24VDC, 120VAC and 240VAC· Four lens colors· Flashing mode standard, configurable

to steady-burn· 60,000 hour LED· 1/2-inch pipe mount· Type 4X, IP66 enclosure· Marine Listed· UL and cUL Listed for Class 1, Division 2

191XL· 24VDC, 120VAC and 240VAC· Four lens colors· Flashing mode standard, configurable

to steady-burn· 60,000 hour LED· 3/4-inch pip mount · Dome guard included· Type 4X, IP66 enclosure· Marine Listed· UL and cUL Listed for Class 1, Division 2

AD-27A· Master control function· 120VAC, 1.47 Amp· 25 watt speaker· Single channel, balanced

line output

Heavy Industrial Intercom SytemsThis fixed line, single-change heavy duty industrial intercom features a NEMA 4X, IP65 cast aluminum housing, integrated Talk/Listen switch, volume control and call button.

XLT (eXtreme Light Technology)XLT is a break through high intensity LED array

designed to meet the demands of industrial customers, providing maximum light ouput

and superior lens fill.

Federal Signal Introduces Hazardous Location with XLT Technology (eXtreme Light Technology)

XLT LEDs

Key Color Voltage Amps Candela Flash Rate

Overall Dim (In.)

Lamp Life (hr) Federal Signal Model Item no. Shpg. Wt.H Dia.

A Amber 24DC 0.38 134 60 15.63 8.82 60,000 27XL-024A 1TAH6 18.4

A Red 24DC 0.38 71.7 60 15.63 8.82 60,000 27XL-024R 1TAH5 18.4

A Amber 120AC 0.21 134 60 15.63 8.82 60,000 27XL-120-240A 1TAH8 18.4

A Red 120AC 0.21 71.7 60 15.63 8.82 60,000 27XL-120-240R 1TAH7 18.4

B Amber 24DC 0.38 211 60 7.5 5.5 60,000 225XL-024A 1TAF7 4.0

B Red 24DC 0.38 97.5 60 7.5 5.5 60,000 225XL-024R 1TAF6 4.0

B Amber 120AC 0.21 211 60 7.5 5.5 60,000 225XL-120-240A 1TAF9 4.0

B Red 120AC 0.21 97.5 60 7.5 5.5 60,000 225XL-120-240R 1TAF8 4.0

C Amber 24DC 0.38 148 60 9.25 5.5 60,000 191XL-024A 1TAH2 4.25

C Red 24DC 0.38 70.8 60 9.25 5.5 60,000 191XL-024R 1TAH1 4.25

C Amber 120AC 0.21 148 60 9.25 5.5 60,000 191XL-120-240A 1TAH4 4.25

C Red 120AC 0.21 70.8 60 9.25 5.5 60,000 191XL-120-240R 1TAH3 4.25

Industrial Intercom

Voltage Amp

Overall Dim (In.)NEMARating

Federal Signal Model

Item no.

Shpg. Wt.H W D

120 1.47 9.88 5.0 6.69 4X AD-27A 3LY36 11

B

C

A

Page 3: Safety Federal Signal Products

Status IndicatorsWhen you encounter an area with process control needs, such as; machine shut down, material shortage, fault, robotic cell activity or tooling change. Grainger offers a complete line of Federal Signal status indicators. Create a column of signaling lights by combining a base and a choice of light modules.

Litestak®

· Available with LED or incandescent lamps · Meets NEMA 1

requirements · UL & cUL listed

based & light · modules, indoor · CSA certified for indoor use

UniStat®

· 70 flashes per minute · Available in tri-color model · Nema 4X, IP66 enclosure · Surface or integrate 3/4” NPT

pipe mount

SemiStat®

· 60 flashes per minute · Flashing and Steady

Burn LED · Choice or tri-color or quad

color models · Piezo sounder with

volume control produces 60 dB @ 10ft. · For indoor use only · Surface Mount

MicroStat®v

· Available in five lens colors (amber, blue, clear, green & red) · Quick and easy lens restacking · Type 4X enclosure · Surface or integrated 3/4” NPT

pipe mount · Crosshatch lens provides bright

full-face illumination

Litestak

Description ColorLamp Life (Hr.) Voltage Amps

Overall Dim (In.) Federal Signal Model

ItemNo.

Shpg.Wt.H Dia.

Bases Standard Base --- --- 120VAC --- 4 4.38 LSB-120 3T949 1.0 Surface-Mount --- --- 120VAC --- 0.25 4.38 LSBS 1N896 0.6 Light Modules Incandescent Light Amber 7000 120VAC 0.13 3.25 4 LSL-120A 3T950 0.7 Incandescent Light Blue 7000 120VAC 0.13 3.25 4 LSL-120B 3T951 0.7 Incandescent Clear 7000 120VAC 0.13 3.25 4 LSL-120C 3T952 0.7 Incandescent Light Green 7000 120VAC 0.13 3.25 4 LSL-120G 3T953 0.7 Incandescent Light Red 7000 120VAC 0.13 3.25 4 LSL-120R 3T954 0.7 LED Amber 100,000 120VAC 0.04 3.25 4 LSLD-120A 3WU45 0.7 LED Blue 100,000 120VAC 0.04 3.25 4 LSLD-120B 3WU46 0.7 LED Clear 100,000 120VAC 0.04 3.25 4 LSLD-120C 3WU47 0.7 LED Green 100,000 120VAC 0.04 3.25 4 LSLD-120G 3WU48 0.7 LED Red 100,000 120VAC 0.04 3.25 4 LSLD-120R 3WU49 0.7 Horns Horn Module --- --- 120VAC 0.04 3 1/4 4 LSH-120 4RM47 0.8

SemiStat

TypeLamp Life (Hr.) Voltage Amps

Overall Dim. (In.) Federal Signal Model

ItemNo.

Shpg.Wt.H W D

4-Light 100,000 24VAC/VDC 0.18 8.14 3.55 1.55 SCB-024QC 5LE18 1.0

3-Light 100,000 24VAC/VDC 0.18 8.14 3.55 1.55 SCB-024TC 5LE19 1.0

Page 4: Safety Federal Signal Products

Warning LightsWhen you approach an area that requires warning but the high ambient noise level is a hindrance, look to Grainger for the complete line of Federal Signal warning lights.

· 40 watt incandescent lamp· 120VAC· Available in 2 dome colors· UL, cUL Listed and

CSA Certified· Type 4X· 1/2” pipe mount or surface mount

· Available in 12VDC, 24VDC & 36VDC · Available in 2 dome colors· 1/2” pipe mount or surface mount· UL Listed, CSA Certified· Type 3R

RotatingFor areas where caution should be exercised, such as process control, start-up, overhead door movement, or where action or movement requires attention, Grainger recommends a rotating light.

Flashing

· 200 watt sealed beam· 120VAC· Available in 2 dome colors· Pivoting lamp yoke· Heavy duty die-cast housing· UL, cUL Listed and CSA Certified· 1” pipe mount or surface mount

· Uses two standard 6VDC lantern batteries· Available in 12VDC · Available in 2 dome colors· 300 hour, 5W

incandescent lamp· Type 3R weatherproof enclosure

BatteryPowered

Warning Lights

Key Color Voltage AmpsPeak

Candela

LampLife (Hr.)

FlashesPer

Minute

Dimensions (In.) Federal

SignalModel

ItemNo.

LotsQty

Shpg.WtH Dia.

A Red 120VAC 0.36 2100 2000 60 6.26 5.13 121S-120R 4A961 3 2.1

A Amber 120VAC 0.36 2100 2000 60 6.26 5.13 121S-120A 4A962 3 2.1

C Red 120VAC 0.80 20,000 2000 60 11.38 9.12 371L-120R 1N747 3 11.8

C Amber 120VAC 0.80 20,000 2000 60 11.38 9.12 371L-120A 1N748 3 11.8

Warning Light Mounting Kit LWMB2 5T588 4 2.9

StrobeFor areas requiring a warning potential dangers like toxic release, treacherous walkways and moving robotic equipment, Grainger offers Federal Signal strobe warning lights.

Flashing Lights

KeyFlasher

TypeFlashesPer Min.

Federal SignalModel

ItemNo.

Shpg.Wt.

D Incandescent 65 BPL26 1N744 2.4

M Strobe 60 BPL26ST 5WF83 3.8

Surface-Mount Strobe LightsA Clear Strobe 80 VALS-120C 1N741 0.3

A Red Strobe 80 VALS-120R 1N740 0.3

Electraflash Flashing

Key Color Voltage Amps Peak Candela Lamp Life (Hr.) Flashes Per Minute

Dimensions (In.) Federal Signal Model Item No. Shpg. WtH Dia.

B Red 12VDC 3.0 325 1000 70 5 5.5 141-012R 1N908 1.1

B Amber 12VDC 3.0 325 1000 70 5 5.5 141-012A 1N910 1.1

B Amber 24VDC 0.90 125 7000 70 5 5.5 141-024A 1N906 1.1

B Amber 36VDC 0.90 200 500 70 5 5.5 141-036A 1N904 1.1

· Available in 12-24VDC, 120VAC and 240VAC· Available in 2 dome colors· 10,000 hour high-intensity

strobe tube· 3/4” pipe mount · UL, cUL Listed and CSA Certified· Type 4X, IP66 enclosure· Marine rated

· Uses two standard 6VDC lantern batteries· Available in 12VDC · Available in 2 lens colors· Type 3R weatherproof

enclosure· Magnetic mount

· Available in 12-24VDC, 120VAC and 240VAC· Available in 2 lens colors· 10,000 hour high-intensity

strobe tube· 1/2” pipe mount · UL, cUL Listed and CSA Certified· Type 4X, IP66 enclosure· Available in 24VDC,

120VAC and 240VAC· Available in 2 lens colors· 10,000 hour strobe tube· 1/2” pipe mount · Dome guard optional· UL & cUL Listed CSA

Certified, CSFM Approved· Type 4X, IP66 enclosure· Marine rated

· Available in 24VDC and 120VAC· Available in 3

dome colors· Incandescent

lamp included· Screw on lens· Surface, Edison &

1/2” pipe mount · UL, cUL Listed

and CSA Certified· Type 4X enclosure

B

D

A

C

E

H

F

I

G

Page 5: Safety Federal Signal Products

Flashing Lights

KeyFlasher

TypeFlashesPer Min.

Federal SignalModel

ItemNo.

Shpg.Wt.

D Incandescent 65 BPL26 1N744 2.4

M Strobe 60 BPL26ST 5WF83 3.8

Surface-Mount Strobe LightsA Clear Strobe 80 VALS-120C 1N741 0.3

A Red Strobe 80 VALS-120R 1N740 0.3

· Available in 120VAC· Available in 2 dome colors· 1/2” pipe mount or

surface mount· 10,000 hour strobe tube· UL, cUL Listed and

CSA Certified· Type 4X, IP66 enclosure

· Available in 12VDC, 24VDC 120VAC & 240VAC· Available in 3 dome colors· Low profile 2.6H x 2.3W x 5L· Surface mount· UL Listed · Type 4X, IP65 enclosure

· Available in 12-48VDC· Available in 2 dome colors· Low profile – only

3-5/8” high· Screw on dome· Surface mount· UL, cUL Listed & CSA Certified· Type 4X enclosure

· Available in 12VDC, 24VDC & 120VAC· Available in 2 dome colors· 4,000 hour strobe tube· 1/2” pipe mount or

surface mount· UL Listed & CSA Certified· Type 3R

· Available in 120VAC· Available in 2 dome colors· Single or double

flash strobe· 10,000 hour strobe tube· 1/2” pipe mount· UL, cUL Listed & CSA Certified· Type 3R, IP45 enclosure

Explosion-ProofKey Color Lamp Life (Hr.) Voltage Amps H D Federal Signal Model Item No. Shpg. Wt.

G Amber 10,000 120VAC 0.6 15.63 8.82 27XST-120ASC 1N751 18.1

G Red 10,000 120VAC 0.6 15.63 8.82 27XST-120RSC 1N750 17.9

Hazardous LocationD Red 10,000 120VAC 0.32 9.25 5.5 151XST-120R 1N754 4.5

D Amber 10,000 120VAC 0.32 9.25 5.5 151XST-120A 1N755 4.5

F Red 10,000 120VAC 0.32 7.5 5.5 225XST-120R 1N900 2.5

F Amber 10,000 120VAC 0.32 7.5 5.5 225XST-120A 1N902 2.5

· Available in 120VAC· Available in 2 lens colors· 40,000 hour strobe tube· Flush or surface mount· UL Listed, CSA Certified · Type 3R, IP44 enclosure

Economical

Key Mounting Type Color Voltage Amps NEMA Rating Dimensions (In.) Federal SignalModel

ItemNo.

Shpg.Wt.

H Dia

G A19 Screw-In Amber 120VAC 0.1 3R 6.06 3.18 LP3E-120A 5WF84 0.7

G A19 Screw-In Red 120VAC 0.1 3R 6.06 3.18 LP3E-120R 5WF85 0.7

G 1/2” Threaded w/Locknut Amber 12-48VDC 0.44-0.1 4X 5.81 3.18 LP3M-012-048A 5WF86 0.7

G 1/2” Threaded w/Locknut Green 12-48VDC 0.44-0.1 4X 5.81 3.18 LP3M-012-048G 5WF87 0.7

G 1/2” Threaded w/Locknut Red 12-48VDC 0.44-0.1 4X 5.81 3.18 LP3M-012-048R 5WF88 0.7

G 1/2” Threaded w/Locknut Amber 120VAC 0.1 4X 5.81 3.18 LP3M-120A 5WF89 0.7

G 1/2” Threaded w/Locknut Green 120VAC 0.1 4X 5.81 3.18 LP3M-120G 5WF90 0.7

G 1/2” Threaded w/Locknut Red 120VAC 0.1 4X 5.81 3.18 LP3M-120R 5WF91 0.7

G 1/2” Threaded w/Locknut Amber 120VAC 0.1 4X 5.75 3.18 LP3P-120A 5WF92 0.7

G 1/2” Threaded w/Locknut Red 120VAC 0.1 4X 5.75 3.18 LP3P-120R 5WF93 0.7

G Flat Surface Amber 12-48VDC 0.44-0.1 4X 5.69 3.18 LP3T-012--048A 5WF94 0.8

G Flat Surface Red 12-48VDC 0.44-0.1 4X 5.69 3.18 LP3T-012--048R 5WF95 0.7

D Flat Surface Amber 12-48VDC 0.44-0.1 4X 3.63 5 LP6-012-048A 5WF96 0.8

D Flat Surface Red 12-48VDC 0.44-0.1 4X 3.63 5 LP6-012-048R 5WF97 0.8

Streamline Low-Profile Mini Strobes

Key Color Voltage L W H Fed Sig Model

ItemNo.

Shpg.Wt.

B Green 120VAC 5 2.3 2.6 LP1-120G

4RM45 0.6

B Red 120VAC 5 2.3 2.6 LP1-120R

4RM46 0.6

Electraflash Strobe

Key Color Voltage Amps Peak Candela

Lamp Life(Hr.)

Flashes PerMinute

Dim. (In.) FederalSignalModel

ItemNo.

Shpg WtH Dia.

E Red 12VDC 0.18 100,000 4000 80 5 5.5 141ST-012R 3T943 1.1

E Amber 12VDC 0.18 100,000 4000 80 5 5.5 141ST-012A 3T944 1.1

E Red 24VDC 0.08 100,000 4000 80 5 5.5 141ST-024R 3T945 1.1

E Amber 24VDC 0.08 100,000 4000 80 5 5.5 141ST-024A 3T946 1.1

E Red 120VAC 0.06 100,000 4000 80 5.25 5.5 141ST-120R 3T947 1.2

E Amber 120VAC 0.06 100,000 4000 80 5.25 5.5 141ST-120A 3T948 1.2

Strobe Warning Lights

Key Color Voltage Amps Peak Candela Lamp Life (Hr.) Flashes Per Minute Dimensions (In.) Fed Signal Model Item No. Lots Qty Shpg. Wt

H Dia.

C Red 120VAC 0.25 1,000,000 10,000 90 5.25 3.94 FB2PST-120R 4A963 3 2.12

C Amber 120VAC 0.25 1,000,000 10,000 90 5.25 3.94 FB2PST-120A 4A964 3 2.12

F Red 120VAC 0.60 1,000,000 10,000 80 8.5 5.7 131DST-120R 4A965 3 2.6

F Amber 120VAC 0.60 1,000,000 10,000 80 8.5 5.7 131DST-120A 4A966 3 2.6

Warning Light Mounting Kit LWMB2 5T588 4 2.9

D E F

A B C

Page 6: Safety Federal Signal Products

When you enter a corrosive atmosphere area with high noise levels, extreme temperatures, dust and humidity, Grainger offers a wide array of Federal Signal audible signals.

Audible Signals

Produces one of four different high decibel tone outputs: wail, yelp, horn or temporal whoop. Rugged, highimpact plastic construction. Resistant to ultraviolet light and is rated NEMA 3R when mounted on No. 4A969 weatherproof box. Unit can be pointed anywhere within 360o

half sphere of area. UL listed indoor/outdoor; cUL listed.

Gasketed trim ring is used to mount No. 4A967 Vibratone Horn. Made of 18-gauge R10 aluminum with neoprene gaskets between mounting surface and plate and between plate and horn.

Low current horn used for producing coded blast or sustained tones for paging, and for start and dismissal signaling indoors or outdoors (with No. 4A969 weatherproof box). Gray powder coat finish with mounting screws included. UL listed; CSA Certified; FM approved.

For weatherproof outdoor surface mounting of No. 4A967 horn, No. 1N742 siren, No. 4A960 and No. 5T589 bells, and No. 5LE20 speaker amplifier. Cast-aluminum gasketed weatherproof box complete with mounting lugs and threaded conduit openings, 1/2” and 3/4”.

Electric horn produces sound by means of a diaphragm, which resonates a column of air. Features

corrosion resistant, cast-aluminum housing with brass projector. Gray powder coat finish. Duty

cycle of five minutes on, five minutes off. UL listed indoor/outdoor, CSA certified.

Designed to draw attention to a ringing phone in high noise areas.

Activated by a ringing signal of an analog phone (between

40-150VAC @16-60 Hz). Feature die-cast

aluminum housing and gray powder coat paint.

Requires duplex jack, not included (order No. 6C080). UL listed for indoor use. FCC approved.

Vibrating bells signal general alarm, start and dismissal, and danger warnings. Mount on standard outlet box. Outdoor applications use No. 4FA969 weatherproof box. Gray powder coat finish. UL listed, CSA certified, and FM approved.

Self-amplified, solid-state signal device with gain control Requires one tone module No. 1N894 listed below (order separately). Used for coded paging, general alarm, start and dismissal, evacuation, and other specific warnings. Gray powder coat finish. UL listed indoor/outdoor. CSA approved.

A

B

Vibratone®Horn

ElectronicSiren

ResonatingHorn

Vibratone®Bells SelecTone®Signal

TelephoneExtensionRingers

Flush-MountTrim

WeatherproofBackBox

C

D

E

F

G

H

Page 7: Safety Federal Signal Products

Audible Signaling Devices

Key Type of Signal Required Power Amps Overall Dim. (In.) Federal Signal Model Item No. Lots Qty. Shipg Wt.

H W D

A Horn, 100 dB @ 10 ft 120VAC, 60 Hz 0.18 4 4 2.5 350-120-30 4A967 4 1.9

B Siren, 111 dB @ 10ft 24VDC, 120/240VAC 0.60 12 14.5 9 SST-MV 1N742 3 6.0

C Horn, 105 dB @ 10 ft 120VAC, 60 Hz 0.75 8 8 19.75 55-120-1 1N745 3 6.4

D 4” Bell, 98 dB @ 10 ft 120VAC, 60 Hz 0.08 4.3 4.3 2.25 504-120 4A960 4 1.5

D 6” Bell, 100 dB @ 10 ft 120VAC, 60 Hz 0.08 6 6 2.63 506-120 5T589 4 2.5

E Weatherproof Box -- -- 4.53 4.53 2.44 WB 4A969 4 1.2

F Trim Plate -- -- 5.56 0.25 --- TR 5LE17 4 0.3

G 4” Bell, 98 dB @ 10 ft 120VAC 0.08 4.20 4.81 5.11 TELB 3LY37 4 3.2

G Horn, 100 dB @ 10 ft 120VAC 0.18 4.81 4.81 5.11 TELH 3LY38 4 3.9

H 110 dB @ 10 ft 120VAC, 60 Hz 0.27 8 12.25 8.25 300GC-120 4A968 2 6.0

I 88 dB @ 10 ft 120VAC, 60 Hz 0.04 4.5 4.5 3.44 50GC-120BG 5LE20 3 2.1

N Tone Module -- -- --- --- --- UTM 1N894 4 0.3

Hazardous Location Audible and Explosion-Proof Signaling Devices

Key Voltage Amps Dimensions (In.) Federal Signal Model Item No. Shpg. Wt.

H W/Dia. D

M 24VDC 0.55 12.3 8 8.25 300GCX-024 3WU52 5.1

M 120VAC 0.27 12.3 8 8.25 300GCX-120 3WU53 6.2

K 120VAC 0.18 5.33 5.33 3.66 350WBX-120 3WU54 3.5

J 120VAC 0.2 7.63 6.5 6.5 31X-120-3 1N749 8.1

L 24VDC, 120 & 240VAC 210 mA 17 13.1 16.3 SSTX-MV 3WU51 22.5

Audible Signals

For exclusive use with No. 4A968, No. 3WU52, and No. 3WU53 audible signals. Micro-controller based tone generator is capable of producing any one of 32 different tones, including; Wail, Yelp, Hi Lo,

Bell, Yeow, Horn, Beep, Stutter, Slow Whoop, Gradual Horn, Temporal Slow Whoop, Westminster Chime, Evac, Air Horn, Chime, 6 Eurotones and more.

UniversalToneModule

LI

N

SelecTone®Speaker/AmplifierMLoudspeaker has built-in volume control. Use with Universal Tone Module No. 1N894 to produce one of 32 different tones. 86dB to 110dB at 10 feet.

ElectricHornJVibrating stainless steel diaphragm produces 100dB at 10 feet. Copper-free, corrosion-resistant, cast aluminum enclosure is tapped for 3/4” mounting feature internal

volume control. NEC Class 1, Div. 1, Groups C & D; Class II, Div. 1 Groups E, F, & G; Class III. UL listed, cUL listed and CSA certified.

Die-CastZincHornKZinc housing with polyurethane finish; surface or flush-mount. For coded or sustained tones. NEC Class 1, Div. 2, Groups A, B, C & D; Class II, Div. 2, Groups F & G; Class III.

Electronic Siren capable of producing three different high decibel tones from the same unit. Designed for stand-alone, high-output in any application where multiple tones are needed but voice paging is not required.

Produces crisp, clear tones, digital voice messages, and live public address. Internal gain control allows output adjustment. Solid-state circuitry. NEMA 3R enclosure. Suitable

for outdoor use when installed with No. 4A969 weatherproof box. Flush or surface mount. UL listed, cUL Listed, CSA certifiedand CSFM approved.

SirenSelecTone®SpeakerAmplifier

Page 8: Safety Federal Signal Products

Fire Alarm Initiating (Input) Devices

FireAlarmPullStations

HeatDetectors

Fire Alarm Signaling (Output) Devices

· Surface mount· FM approved· UL listed

· LEDs on units give visual indication of alarm activation · Include test switch· UL listed

SmokeDetectors

IonizationTypeResponds quickly to fast-burning, low-smoke fires by sensing air-born combustion particles.PhotoelectricTypeDetects dark or thick smoke and responds quickly to slow-smolder-ing, high-smoke fires.DuctActivates when combustion particles exceed 2.3% per feet in air moving at 100 to 4000 feet per minute. Includes housing and detector; use with sampling tube no. 4BY49.SmokeSamplingTube5-foot tube for use with detector No. 4BY48 can be trimmed for shorter duct distances.

Initiating

Description Coverage(Sq. Ft.)*

Federal SignalModel

StockNo.

Shpg.Wt.

Single-Action Fire Alarm Station --- FSF103 4BY45 3.8

Dual-Action Fire Alarm Station --- FSF102 4BY44 1.4

Combination Heat Detector - 200 2500 FSF101SB 4BY43 0.6

Combination Heat Detector - 135 2500 FSF100 4BY42 0.5

Ionization Type Smoke Detector 900 FSF110SB 4BY51 0.7

Photoelectric Type Smoke Detector 900 FSF109 4BY50 0.9

Duct Smoke Detector --- FSF107 4BY48 4.4

Smoke Sampling Tube --- FSF108 4BY49 2.4

(*) Coverage at 30-ft. spacing, except Nos. 4BY43 and 4BY42 are 50-ft. spacing

Signaling (Output) Devices

Description Dimensions (In.) Alarm Current (Amps) Operating Voltage (VDC) Flash (Candela) Peak Output (dBA at 10 Ft.) Fed Signal Model Stock No. Shpg. Wt.

H W L

Fire Alarm Bell 7 3 7 0.012 24 --- 87 FSF106-024R 4BY41 1.4

Fire Alarm Horn 4 3 4 0.030 24 --- 85 FSF104-024R 4BY47 0.6

Fire Alarm Chime 6 3 6 0.040 24 --- 85 FSF105-024R 4BY46 0.5

Fire Alarm Strobe 6 3 6 0.016 24 75/110 --- FSF205ST-024R 4BY61 0.7

Fire Alarm Strobe 6 3 6 0.073 24 15/75 --- FSF204ST-024R 4BY54 0.7

Fire Alarm Horn/Strobe 6 3 6 0.089 24 15/75 88 FSF200ST-024R 4BY53 0.7

Fire Alarm Horn/Strobe 6 3 6 0.149 24 110 87 FSF201ST-024R 4BY60 0.7

Sychronization Module 6 3 6 0.009 24 --- --- FSF206 4BY62 0.6

FireAlarmBell6” vibrating motor bell is red and includes mounting plate.FireAlarmHornHigh energy horn can be operated in continuous or tem-poral (on-off) mode.FireAlarmChimeIndoor-mount chime has adjustable volumeFireAlarmStrobesIndoor strobes flash once per second. Includes trim plate.

FireAlarmHornsandStrobesIndoor units provide combination of synchro-nized audible and visual signals. Horn pattern can be set to continuous or temporal (On-Off) model. Includes trim plate.SynchronizationModuleSynchronizes strobes or horn/strobes in fire alarm systems up to 3 amps per circuit. Meets UL 1971 standards.

Grainger offers signaling systems that are designed to ensure safety, sound alarms, increase productivity, or provide a means of communication. Federal Signal initiating devices are the cost–effective method of activating audible and visual signals.

Combination-135o

Detector activates either at a fixed temperature of 135oF or at a 15oF per minute rate-of-rise in temperature.Combination-200o

Detector activates at a fixed temperature of 200oF or at a 15oF per minute rate-of-rise in temperature.

Can be used as either break-glass or non-break-glass type. Stations mount on 4” square single gang electrical boxes. Die-cast body is painted red.

Page 9: Safety Federal Signal Products

Back Up Alarms

· Produces two distinct tones – puls and constant-on· Impact resistant housing· Designed for multi-volt operation· Conforms with SAE and · OSHA requirements· Universal Mounting bracket

· 97dB at 4’· 60 pulses per minute· Conforms to SAE J994 Sound · Level Type C· Type 4X enclosure

· Adjusts sound output automatically· 80 pulses per minute· Operates on 12-48VDC power· UL listed· Type 4X enclosure

Vehicle Back-Up Alarms

Key Voltage Amps Decibels(dB)

Fed Signal Model

ItemNo.

Shpg.Wt

A 9 to 48VDC 0.04 97 EPBA 2YE26 0.6

B 12-48VDC 0.2 97 at 4Ft 252-012-048 1N898 0.7

C 12-48VDC 0.25 82 - 107 at4Ft 253-012-048 4RM40 1.6

A

C

B

Designed for use in a wide variety of vehicles that operate in populated areas – both indoor and outdoor.

Sentry

Key Color Voltage Amps LampLife(Hrs.)

FlashesPerMin.

Dim. (In.) FedSignalModel

ItemNo.

Shpg.Wt.

H Dia.

A Amber 12VDC 4.3 1000 95 6.5 6.4 448142 3WU44 2.8

Highlighter Mini Lightbars

B Strobe Amber 12-24VDC

--- 15 9 5 453201-02

2YE25 5

D Parabolic Amber 12VDC 8.6 15.8 7 5.3 HLCM-A 3LY39 8.1

Pulsator

Key Color Voltage Amps FlashesPerMin.

Dim. (In.)

FederalSignalModel

ItemNo.

Shpg Wt.

H Dia

Magnetic Mount

C Amber 12-48VDC 0.9-0.25 80 4 6.5 211682-02 2YE24 1.6

Hard Wire

C Amber 12-48VDC 0.9-0.25 80 4 6.5 211823-02 2YE23 1.6

C Amber 12-48VDC 1.4 120 6 6.5 211832 3WU43 1.9

Magnet Mount Rotating Light

Key DomeColor

Voltage Amps Dimensions FederalSignalModel

ItemNo.

ShpgWt.

L W R

E Amber 12VDC 4.3 5.1 3.8 4.8 FB3SM-A 4RM42 2.1

E Blue 12VDC 4.3 5.1 3.8 4.8 FB3SM-B 4RM43 2

· 80,000 candelas per flash· Meets SAE J845 Class 1 requirements· Large parabolic reflector · 55 watt halogen bulb· Dome and base are impact-resistant · polycarbonate· Magnetic Mount with 10 ft. cord with · cigarette lighter plug or hard wire

A

· 55 watt halogen lamp produces · 68,000 candelas· 95 or 175 flashes per minute· Dome and base are · impact-resistant polycarbonate· Swivel and magnetic mount with · 10 ft. cord with cigarette lighter plug· Conforms to SAE J845

C

· 1,000 hour lamp life· Meets SAE J1318 Class 2 requirements· Helical halogen strobe tube· Dome and base are · impact-resistant polycarbonate

E

· 65 flashes per minute· Hard wired· Provides quad flash 9 joules· Conforms to SAE J1318 · Class 2 requirements

StrobeB

· 95 flashes per minute· 55 watt halogen lamps produce · 80,000 candelas· Magnetic mount with 10 ft. cord · with cigarette lighter plug· Conforms to SAE J845 · Class 1 requirements

ParabolicD

Vehicular Warning LightsLet Grainger get your vehicle ready for safety. Federal Signal’s attention-getting warning signals can attach to vehicles such as fork lifts, dump trucks, waste disposal vehicles and tow trucks.

Page 10: Safety Federal Signal Products

The following chart demonstrates the role distance plays in the “loudness” of an audible signal. Most of ourdevices are measured at a distance of 10 feet (on axis); Outdoor Warning Sirens are measured at 100 ft. (onaxis). This gives us a common point for comparison.

To understand the range of these devices, use a 6dB loss per distance doubled for the regular devices and a10dB loss per distance doubled for outdoor sirens.

For example, a regular device produces 6dB less at a distance of 20' than at 10'. An outdoor warning device is 10dB less at 200' than at 100'.

Purpose Ambient Noise Coverage

Purpose Determine whether the signal will be used for the monitoring of a process or for emergency notification (fire, chlorine leak, natural disasters). Study operational uses such as start/stop work, coded pagingand voice messages. Also, the type of duty cycle (i.e.: time device is on vs. time off) will determine what device isbest suited for a given application.

Ambient Ambient noise levels and the frequency (low or high) are critical in determining the type of device Noise to be recommended. Most facilities will have already recorded this information for OSHA compliance.

Coverage How big of an area is to be covered? Coverage requirements dictate the type(s) and number of devices that will beneeded. A plot plan of the plant or a blueprint of the building can be very helpful in determining area of coverage,and help analyze what obstructions might be a factor in complete plant coverage.

Measuring Sound

X

100'127dB

200'117dB

400'107dB

OUTDOOR

Prefix First # — SolidsIP 0 — No ProtectionIP 1 — Over 50mmIP 2 — Over 12mmIP 3 — Over 2.5mmIP 4 — Over 1.0mmIP 5 — Dust, limited ingress from

all directionsIP 6 — Total protection against dust

Prefix Second # — WaterIP 0 — No ProtectionIP 1 — DrippingIP 2 — Dripping when tilted up to 15ϒIP 3 — Spraying when tilted up to 60ϒIP 4 — SplashingIP 5 — Low pressure jetsIP 6 — Strong jets

IP RatingsIngress Protection

Type Indicates:

1 General Purpose, Indoor — To prevent accidental contact of personnel with theenclosed equipment in areas where unusual service conditions do not exist.Provide protection against falling dirt.

2 Drip-Proof, Indoor — Similar to Type 1, but also protects against falling non-cor-rosive liquids and falling dirt. Drainage provisions provided.

3 Dust-Tight, Rain-Tight, Sleet-Resistant, Outdoor — Protected against wind-blown dust and water.

3R Rainproof, Sleet-Resistant, Outdoor — Protected against rain.

3S Dust-Tight, Rain-Tight and Sleet-Proof, Outdoor — Protected against windblowndust and water, remains operable when covered by external ice or sleet. (Not pro-tected against internal icing.)

4 Water-Tight and Dust-Tight, Indoor and Outdoor — Protected against wind-blown dust and rain, splashing water, seepage water, falling or hose-directedwater, and severe external condensation. Mountings are external to cavity.

4X Water-Tight, Dust-Tight, Indoor and Outdoor — Same as Type 4 but also corro-sion-resistant. Passes 200-hr. salt spray (fog) test.

Nema RatingsNational Electrical Manufacturers Association

How To Choose An Audible Signal

Enclosure Rating Reference Guide

When choosing a signal for an application, remember the acronym PAC. If you determine a signal’s PURPOSE, the AMBIENT NOISE of the environment and the area of COVERAGE that is needed, you will be able to fit the right device to your application.

Page 11: Safety Federal Signal Products

GlossaryAlarm: A signal for attracting attention to an event.

AmbientNoiseLevel: The level of acoustic noise existing at a given location, such as in a room, in a compartment, or at a place outside.

Amplifier: An electronic component that boosts the voltage or power level of a signal.

Beacon: A device used to produce a visible indication of an event.

Candela(cd): The standard unit for luminous intensity.

CrosshatchLens: The pattern of the plastic material of the lens that results in a brilliant illumination of the signal.

Decibel(dB): A unit used to convey the intensity of sound.

DipSwitch: Stands for Dual Inline Package switch, one of a set of small (sometimes very small) toggle switches on a circuit board that are used for configuring the device.

Dome: The top component of a visual signal—manufactured in various colors to create different color signals.

GainControl: A device that adjusts the gain of an amplifier by altering the amount of negative feedback in the amplifying system. Note: Not the same as volume control.

HalogenBulb: A bulb filled with halogen gas, a substance that causes the particles of tungsten to be redeposited onto the tungsten filament. This process extends the lamp’s life and also makes the light whiter and brighter.

FMApproved: FM stands for Factory Mutual, a third party approval and certification company that performs rigorous testing to specifications to ensure products meet or exceed their claims.

Housing: A protective cover designed to contain or support a light or horn. Often constructed of polycarbonate or die-cast aluminum.

IP: Is an international classification system to classify the Ingress Protection of an enclosure against solids and liquids as prescribed in the International Standard IEC 60529. For additional information on the IP classification system, see the Federal Signal product catalog or website

IncandescentLamp: A light source that uses electricity to heat up a filament until until it gets so hot that it glows bright.

Lamp: A complete light source unit, usually consisting of a light generating element (arc tube or filament), support hardware, enclosing envelope and base.

LED: Stands for Light Emitting Diode. A diode designed to give off light when current flows through it.

LEDLamp: The bulb or tube portion of an electric lighting device.

Low-Profile: A signal that is short in physical size. A low profile signal might be used in a location with limited or small space.

Lumen: A unit of measurement quantifying the amount of light emitted from a light source.

NEC: National Electrical Code, developed and published by the National Fire Protection Association.

NEMA: National Electrical Manufacturers Association. NEMA provides a forum for the standardization of electrical equipment. See the Federal Signal product catalog or website for a complete listing of NEMA ratings.

NemaType1: Intended for use primarily to provide a degree of protection against limited amounts of falling dirt.

NemaType3R: Intended for outdoor use primarily to provide a degree of protection against rain, sleet, and damage from external ice formation.

NemaType4X: Intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, hose-directed water, and damage from ice formation

ParabolicReflector: A reflective device formed in a dish (concave) shape which helps produce a parallel light towards its focused direction.

Polycarbonate: An engineering plastic used to build housings; noted for its impact-, weather-, and heat-resistant qualities.

PowderCoatFinish: A mixture of finely ground particles of pigment and resin which is then sprayed onto a surface and cured with a heat process. Powder coat finishes are attractive, high quality, and are resistant to chipping, scratching, UV damage and rust.

SAE:Society of Automotive Engineers, an organization that develops the standards to help advance mobility engineering.

SAEStandardJ845: The standard for optical warning devices for emergency vehicles (single color, 360 degree lights).

SAEStandardJ994: The standard for vehicle electric back-up alarm devices.

SAEStandardJ1318: The standard for gaseous discharge warning lamp for authorized emergency, maintenance and service vehicles.

ToneOutput: The sound that comes out of an electronic siren. Federal Signal products have various tones such as wail, yelp, whoop, voice tones and more.

RotatingLight: A continuous beam of light that rotates inside the housing.

StatusIndicator: A signal used to indicate the status of an event, such as the startup of machinery.

StrobeLight: A device that emits a bright flashes of light at a timed rate. Strobe lights use xenon-gas tubes and are typically brighter than flashing lights.

Tone: Refers to the sound that emits from a horn. Federal Signal has products with various tone styles such as wail, yelp,

UL:Underwriters Laboratories Inc., an organization that tests products for public safety.

cUL: The Canadian approval given by Underwriters Laboratory that meet the safety standards for Canada.