   For the gateway station you will have to change the following fields:  

● in Subscriber Unit Parameters, you will set a value for gateway’s Radio ISSI  

     

●  in Feature Flags, you will set the  

 

❏ GPS will be unchecked 

 

 

   

CPS 6.2 R 06.20.09.00 Radio MTM5400  2 

 

 

●  in PEI Parameters, you will set the 

 

❏ Baud Rate values to 9600 ❏ Parity Bit value to PARITY_NONE ❏ Flow Control value to No flow control ❏ Stop Bits value to 1 ❏ Data Bits value to 8 

  

   

● in AT commands, you will set the 

 

❏ ETSI AT SDS/Status Format will be unchecked ❏ Extended ETSI Addressing will be unchecked 

 

 

 

 

   

CPS 6.2 R 06.20.09.00 Radio MTM5400  3 

 

User radio CPE file MTP850E 

 ● GPS Settings  

❏ GPS Authorized ISSI Base will be set to the                 Gateway’s Radio ISSI value 

❏ GPS Location Protocol value will be set to LRRP ❏ GPS Coordinates value will be set to             

Latitude/Longitude ❏ GPS in DMO value will be set to Enabled in Any DMO                       

Mode  

  SafeMobile Tetra Gateway Application is working only with LRRP Protocol: 

●  LRRP Configuration  ❏ GPS SDS TL Disabled will be unchecked 

  Note: TETRA radios have their GPS refresh interval set in their codeplug so the                           value which is setup in Subscriber and User management (Administrative                   module) is not used.     

CPS 6.2 R 06.20.09.00 Radio MTM5400  4 

 

 LRRP Profiles will be used to make subscriber radios send periodic GPS                       reports. 

●  LRRP Profiles: Status Profile ❏ GPS Event Location Enable will be checked ❏ GPS Event Timestamp Enable will be checked ❏ GPS LRRP Destination ISSI will be set to the                 

Gateway’s Radio ISSI value   

    

●  LRRP Profiles: Normal Periodic Profile ❏ GPS Event Location Enable set to TRUE (checked) ❏ GPS Event Timestamp Enable set to TRUE (checked) ❏ GPS LRRP Destination ISSI will be set to the Gateway’s                   

Radio ISSI value ❏ GPS Idle Report Period set to an integer value 

  

      

CPS 6.2 R 06.20.09.00 Radio MTM5400  5 

 

  

●  LRRP Profiles: Emergency Periodic Profile ❏ GPS Event Location Enable set to TRUE (checked) ❏ GPS Event Timestamp Enable set to TRUE (checked) ❏ GPS LRRP Destination ISSI will be set to the Gateway’s                   

Radio ISSI value   

    

●  LRRP Profiles: Powerup Profile ❏ GPS Event Location Enable set to TRUE (checked) ❏ GPS Event Timestamp Enable set to TRUE (checked) ❏ GPS LRRP Destination ISSI will be set to the Gateway’s                   

Radio ISSI value   

       

CPS 6.2 R 06.20.09.00 Radio MTM5400  6 

 

 ●  LRRP Profiles: Powerdown Profile 

❏ GPS Event Location Enable set to TRUE (checked) ❏ GPS Event Timestamp Enable set to TRUE (checked) ❏ GPS LRRP Destination ISSI will be set to the Gateway’s                   

Radio ISSI value  

  

 

●  LRRP Profiles: Emergency Entry Profile ❏ GPS Event Location Enable set to TRUE (checked) ❏ GPS Event Timestamp Enable set to TRUE (checked) ❏ GPS LRRP Destination ISSI will be set to the Gateway’s                   

Radio ISSI value  

     

CPS 6.2 R 06.20.09.00 Radio MTM5400  7 

 

Tetra Gateway application Check that the station is connected using a data cable (GMKN1022A for MTM800 or 

newer for MTM5400) and not a programming cable!  To start the Tetra Gateway application, you will double click the TetraGW                       shortcut. 

  

In the opened window, you will select click “Connect”, after you have                       selected  the serial communication port under “Port name” dropdown list.  

  

● Status – indicates the current gateway satsys ● Last update –  time of last radio data received ● Autoconnect – option is available, will apply to next restart of gateway                       

application.  

Tetra Gateway console when first started, status disconnected. It shows                   the available ports (the serial ports in PC). 

 

CPS 6.2 R 06.20.09.00 Radio MTM5400  8 

 

 After connecting the radio station, the gateway console will display                   

messages about the state of gateway connection, gps , sms and others.  

  

   

“Send keep Alive Request” console message ­ The gateway checks the                     radio connection status and will try to reconnect if the radios is powered off or                             restarted (expected delay time at reconnection is 10­30 seconds). 

   

    

CPS 6.2 R 06.20.09.00 Radio MTM5400  9 

 

 Gateway “Status” label will indicate current gateway activity:  

● Serial port closed – awaiting user to select serial port and click “Connect” ● Serial port opened – connection with serial port established, looking for                     

attached radio ● Communication with radio established – ready to receive data from                   

radio network ● Failed to communicate with radio – failed to bind to radio, will retrying                         

every 30 sec.  

  

● Last Update timestamp label is updated for every LRRP Trigger received                     (gps, sms, ars) 

 