s5b - design details and technical notes appendices : a update for pdf dk ... page 8 october 2003...
TRANSCRIPT
PAGE 2 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
TABLE OF CONTENTS
INTRODUCTION ..................................................................................................................................4
APPENDICES ........................................................................................................................................5
1 PLANT INSTALLATION ...........................................................................................................6 1.1 DETAIL OF TUBESTOCK PLANTING IN JUTEMAT (CONTINUOUS OR SQUARES)..........................7 1.2 DETAIL OF EVERGREEN TREE PLANTING OVER 2M TALL.........................................................8 1.3 DETAIL OF TREE GUARD .........................................................................................................9 1.4 DETAIL OF EVERGREEN TREE PLANTING UNDER 2M TALL.....................................................10 1.5 DETAIL OF SHRUB PLANTING................................................................................................11 1.6 DETAIL OF INDICATIVE ROUNDABOUT PLANTING.................................................................12 1.7 DETAIL OF INDICATIVE TREE PLANTING IN ROUNDABOUT ....................................................13 1.8 DETAIL OF GRADE REQUIREMENTS FOR PLANTING AND ACCESS...........................................14
2 IRRIGATION DETAILS...........................................................................................................15 2.1 DETAIL OF OVAL IRRIGATION ...............................................................................................16 2.2 DETAIL OF AUTOMATIC POP-UP SPRAYHEAD, SPRINKLER CONNECTION................................17 2.3 DETAIL OF SECTION OF VALVES AND VALVE BOX. ...............................................................18 2.4 IRRIGATED KICKABOUT AREA CONSTRUCTION DETAIL .........................................................19
3 PLAYSPACE DESIGN CHECKLIST......................................................................................20 3.1 PLAYSPACE DESIGN CHECKLIST ..........................................................................................20
4 PATH CONSTRUCTION DETAILS .......................................................................................21 4.1 DETAIL OF GRANITIC GRAVEL PATH. ....................................................................................22 4.2 DETAIL OF ASPHALT FOOTPATH WITH BRICK SWALE. ...........................................................23 4.3 DETAIL OF COLOURED CONCRETE PAVING WITH TILE BANDING. ..........................................24 4.4 DETAIL OF RESERVE PATH, SHARED FOOT/BICYCLE PATH.....................................................25
5 BOLLARD AND FENCING DETAILS ...................................................................................26 5.1 DETAIL OF TIMBER POST & RAIL BARRIER ............................................................................27 5.2 DETAIL OF TIMBER POST & STEEL RAIL BARRIER..................................................................28 5.3 DETAIL OF GABLE END BOLLARD .........................................................................................29 5.4 DETAIL OF BEVEL END BOLLARD..........................................................................................30 5.5 DETAIL OF GABLE END BOLLARD WITH RECESS. ...................................................................31 5.6 DETAIL OF REMOVABLE BOLLARD AND SQUARE OPTIONS ....................................................32
6 PARK FURNITURE DETAILS ................................................................................................33 6.1 DETAIL OF TIMBER SLAT BENCH...........................................................................................34 6.2 DETAIL OF METAL BENCH SEAT. ...........................................................................................35 6.3 DETAIL OF PICNIC TABLE WITH ATTACHED SEATS. ...............................................................36 6.4 DETAIL OF PICNIC TABLE WITH NON-ATTACHED SEATS. .......................................................37 6.5 DETAIL OF TABLE AND SEAT FIXING. ....................................................................................38 6.6 DETAIL OF DRINKING FOUNTAIN – STANDARD......................................................................39 6.7 DETAIL OF DRINKING FOUNTAIN – ACCESSIBLE....................................................................40 6.8 DETAIL OF RUBBISH BIN ENCLOSURE....................................................................................41 6.9 DETAIL OF RUBBISH BIN SECURITY POSTS. ...........................................................................42 6.10 DETAIL OF BIKE RACK AND FOOTINGS. .................................................................................43 6.11 DETAIL OF RESERVE POLE LIGHT. .........................................................................................44 6.12 DETAIL OF ELECTRIC BBQ UNIT. .........................................................................................45
7 SIGNAGE GUIDELINES ..........................................................................................................46 7.1 FORMATTING........................................................................................................................46
7.1.1 Colour.............................................................................................................................46
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 3 TECHNICAL NOTES FOR OPEN SPACE
7.1.2 Font.................................................................................................................................46 7.1.3 Heading ..........................................................................................................................46 7.1.4 Information Area ............................................................................................................46 7.1.5 Bottom Strip....................................................................................................................46
7.2 DETAIL OF FACILITY NAME SIGNAGE....................................................................................47 7.2.1 Uses ................................................................................................................................47 7.2.2 Locations ........................................................................................................................47 7.2.3 Construction notes ..........................................................................................................47
7.3 DETAIL OF INTERPRETATION SIGNAGE .................................................................................48 7.3.1 Uses ................................................................................................................................48 7.3.2 Locations ........................................................................................................................48 7.3.3 Construction notes ..........................................................................................................48
7.4 DETAIL OF GATEWAY SIGNAGE ............................................................................................49 7.4.1 Uses ................................................................................................................................49 7.4.2 Locations ........................................................................................................................49 7.4.3 Construction notes ..........................................................................................................49
7.5 DETAIL OF SUBURB SIGNAGE................................................................................................50 7.5.1 Uses ................................................................................................................................50 7.5.2 Locations ........................................................................................................................50 7.5.3 Construction notes ..........................................................................................................50
8 SHELTERS AND GAZEBOS....................................................................................................51 8.1 DETAIL OF HEXAGONAL PICNIC PAVILION. ...........................................................................52 8.2 DETAIL OF SQUARE PICNIC PAVILION ...................................................................................53
9 WATER FEATURES AND WETLAND DETAILS................................................................54 9.1 DETAIL OF STORMWATER OUTLET FOR LARGE DIAMETER PIPES ...........................................55 9.2 DETAIL OF EPHEMERAL POND & SETTLING POND .................................................................56 9.3 DETAIL OF PERMANENT ORNAMENTAL POND......................................................................57
10 RECOMMENDED SPECIES LIST..........................................................................................58
11 GUIDE TO REVEGETATION IN HUME WITH INDIGENOUS SPECIES ......................59
12 NEW ASSET INSPECTION SHEET .......................................................................................60
13 LIST OF INDIGENOUS PLANT SUPPLIERS.......................................................................61
14 LANDSCAPE TREATMENTS TABLE...................................................................................62 14.1 APPROPRIATE LANDSCAPE TREATMENTS FOR NEIGHBOURHOOD LANDSCAPE CHARACTER TYPES 62 14.2 APPROPRIATE CANDSCAPE TREATMENTS FOR SUBREGIONAL LANDSCAPE CHARACTER TYPES 63 14.3 APPROPRIATE LANDSCAPE TREATMENTS FOR REGIONAL LANDSCAPE CHARACTER TYPES....64 14.4 APPROPRIATE LANDSCAPE TREATMENTS FOR ROADSIDE LANDSCAPES.................................65
15 LIST OF REFERRAL DOCUMENTS .....................................................................................66
16 POLICY FOR THE PROTECTION OF VEGETATION IN IDENTIFIED VEGETATION PROTECTION AREAS (VPAS).........................................................................................................67
16.1 POLICY BASIS.......................................................................................................................67 16.2 OBJECTIVE ...........................................................................................................................67 16.3 POLICY.................................................................................................................................67 16.4 NON-COMPLIANCE DIRECTIVE..............................................................................................68 16.5 REVIEW................................................................................................................................68
PAGE 4 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
INTRODUCTION These appendices form the second part of the Hume City Council Design Details and Technical Notes for Open Space document.
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 5 TECHNICAL NOTES FOR OPEN SPACE
APPENDICES Appendix 1 Plant installation Appendix 2 Irrigation details Appendix 3 Kickabout area construction detail Appendix 4 Playspace design checklist Appendix 5 Path construction details Appendix 6 Bollard and fencing details Appendix 7 Park furniture details Appendix 8 Signage guidelines Appendix 9 Shelters and gazebos Appendix 10 Water features and wetland details Appendix 11 Recommended species list Appendix 12 Guide to revegetation in Hume with indigenous species Appendix 13 New asset inspection sheet Appendix 14 List of indigenous plant suppliers Appendix 15 Landscape treatments table Appendix 16 List of referral documents Appendix 17 Hume City Council Vegetation Protection Policy
PAGE 6 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
1 PLANT INSTALLATION
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 7 TECHNICAL NOTES FOR OPEN SPACE
1.1 Detail of tubestock planting in jutemat (continuous or squares)
20-25mm Ø TUBE STO CK TO BE H EALTH Y-DISEASE FREE SPECIMENS. WATER TUBES TH E DAY O F PLANTING , R EMOVE PLANT FROM TUBES AT TIME O F PLANTING
PR O TECT TUBE STO CK WITH 3No. 750x18x225mm H .W. STAKES DRIVEN 150mm INTO GR O UND AND 450 X 350 X 1 mm EXTR UDED POLYETHYLENE TR EE GUAR D (WH ER E NECESSAR Y) INSTALLED AT GROUND LEVEL AND SLEEVES TAUGH T BETWEEN STAKES
O VER -EXCAVATE H O LE BY AT LEAST TWO TIMES POT VOLUME. ENSURE SIDES O F H O LE AR E R O UGH ENED. BACKFILL WITH SITE SOIL. WATER AFTER PLANTING AND DUR ING ESTABLISHMENT PERIOD.
EXISTING SITE SO IL (UNCULTIVATED)NO TE: IN SO ME CIR CUMSTANCES SITE SO IL WILL REQUIRE CULTIVATION.
CO NTINUO US MAX-JUTE F IBR E MAT R O LL (R EFER DIMENSIONS BELOW) STEEL PINNED O R PEGGED AT A R ATE O F 2-3 PINS/PEGS PER MTRE. SQ. O VER LAP AT JO INTS BY 300mmORPLACE 600mm SQ . JUTE MAT F IBR E SQ UAR ES AND SECURE BY DIGGING O UTER 100mm EDGES F IR MLY INTO GR O UND AND STEEL PEGGED AT COR NERS
JUTEMAT R O LL DIMENSIONS: LENGTH : 30mWIDTH S AVAILABLE: 370mm, 600mm, 1830mm, AND 3660mm.MASS: Thick - 750-800gms/mtre.sq.DENSITY : Thick -125-130kg/mtre.cubed
STEEL PIN O R PEG
Rev. Detail
SCALE: NTS
AmendmentsInitials Date
SEPT 2002
450
150
750
R OOT BALL
DWG :
LD00107.07.05DKUpdate for PDFA
C O N T I N U O U S / S Q U A R E J U T E M A TT U B E S T O C K P L A N T I N G W I T H
S ta n d a rd La n d sc a p e D ra w in g s
PLANTING DETAILS
PAGE 8 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
1.2 Detail of evergreen tree planting over 2m tall
TR EES STAKED & TIED TO 3 No. 1800x25x25mm H .W.STAKES WITH FLEXIBLE R UBBER O R CANVAS IN FIGURE '8' CO NFIGURATION
ROOTBALL
SAUCER -SH APED BO WL FORMED TO HOLD AT LEAST 4 LITR ES OF WATER
100gm O F O SMO CO TE SLO W R ELEASE FERTILISER O R SIMILAR . ADD WATER STORING GRANULES ACCO R DING TO MANUFACTUR ER 'S INSTRUCTIONS.
75mm LAYER O F SH R EDDED PINE WOOD MULCH TO 1m DIAMETER
PR O PO SED EVER GR EEN TREE TO BE H EALTH Y DISEASE-FR EE SPECIMENS. WATER TR EES IN TH EIR POTS THE DAY OF PLANTING AND R EMO VE FROM POTS AT TIME O F PLANTING.
EXISTING SO IL PROFILE
O VER -EXCAVATE H O LE BY AT LEAST THREE TIMES PO T WIDTH . ENSUR E SIDES OF HOLE AR E R O UGH ENED. BACKFILL WITH IMPORTED WEEDFR EE TO PSO IL, IF R EQUIRED. WATER IMMMEDIATELY AFTER PLANTING AND R EGULAR LY DUR ING EXTABLISHMENT PERIOD.
EXISTING SUBGRADE
75
PLACE 65/90mm DIAMETER AG-PIPE INTO PLANT H O LE PR IO R TO PLANTING TO EXTEND 25mm O NLY ABO VE FINISHED MULCH LEVEL
E V E R G R E E N T R E E P L A N T I N GO V E R 2 M T A L L
PLANTING DETAILS
LD002Update for PDF
Amendments
ARev. Detail
DK 07.07.05
SCALE: NTSSEPT 2002
DateInitials DWG :
S ta n d a rd La n d sc a p e D ra w in g s
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 9 TECHNICAL NOTES FOR OPEN SPACE
1.3 Detail of tree guard
GALVANISED STEEL SOLID R OD R INGS
GALVANISED STEEL PLATE FINS
288
368
1500
GR O UND LINE
F IX TREE GR ATE TO GR O UND AS PER MANUFACTURER'S DIR ECTIONS
PO WDER CO ATED - CO LO UR TO CO UNCIL'S APPR OVAL
PLAN VIEW
UPPER RING
LOWER R INGS
T R E E G U A R D
PLANTING DETAILS
LD003Update for PDF
Amendments
ARev. Detail
DK 07.07.05
SCALE: NTSSEPT 2002
DateInitials DWG :
S ta n d a rd La n d sc a p e D ra w in g s
PAGE 10 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
1.4 Detail of evergreen tree planting under 2m tall
TR EES STAKED & TIED TO 2 NO . 1500x25x25mm H .W.STAKES WITH FLEXIBLE R UBBER OR CANVAS IN F IGUR E '8' CO NFIGURATION
R OOT BALL
SAUCER -SH APED BO WL FO R MED TO HOLD AT LEAST 4 LITR ES OF WATER
100gm O F O SMO CO TE SLO W R ELEASE FERTILISER O R SIMILAR . ADD WATER STORING GRANULES ACCO R DING TO MANUFACTUR ER 'S INSTRUCTIONS.
75mm LAYER O F SH R EDDED PINE WOOD MULCH TO 1m DIAMETER
PR O PO SED EVER GR EEN TR EE TO BE HEALTHY DISEASE-FR EE SPECIMENS. WATER TREES IN TH EIR PO TS TH E DAY O F PLANTING AND REMOVE FR O M PO TS AT TIME OF PLANTING.
EXISTING SO IL PROFILE
O VER -EXCAVATE H O LE BY AT LEAST THREE TIMES PO T WIDTH . ENSUR E SIDES OF HOLE ARE R O UGH ENED. BACKFILL WITH IMPORTED, WEEDFR EE TO PSO IL, IF R EQ UIRED. WATER TREES IMMEDIATELY AFTER PLANTING AND REGULARLY DUR ING EXTABLISH MENT PERIOD.
EXISTING SUBGRADE
25
PLACE 65/90mm DIAMETER AG-PIPE INTO PLANT H O LE PR IO R TO PLANTING TO EXTEND 25mm O NLY ABO VE F INISH ED MULCH LEVEL
E V E R G R E E N T R E E P L A N T I N GU N D E R 2 M T A L L
PLANTING DETAILS
LD004Update for PDF
Amendments
ARev. Detail
DK 07.07.05
SCALE: NTSSEPT 2002
DateInitials DWG :
S ta n d a rd La n d sc a p e D ra w in g s
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 11 TECHNICAL NOTES FOR OPEN SPACE
1.5 Detail of shrub planting
150mm LAYER O F IMPO R TED GO O D Q UALITY, FREE DRAINING TOPSOIL.
75mm LAYER O F SH R EDDED PINE WOOD MULCH
150mm LAYER CULTIVATED SITE SOIL
SPR EAD O SMO CO TE SLO W R ELEASE FER TILISER OR SIMILAR @ 15gm/TUBE, 25gm/150mm PO T, 50gm/300mm POT.
R OOT BALL
75
SH R UBS TO BE H EALTH Y-DISEASE FR EE SPECIMENS. TYPICAL SHRUB FROM 150-300mm DIAMETER PO TS. WATER PLANTS IN THEIR POTS THE DAY OF PLANTING AND R EMO VE PLANT FROM POT
O VER -EXCAVATE H O LE BY AT LEAST THREE TIMES POT WIDTH . ENSUR E SIDES O F H O LE AR E ROUGHENED. BACKFILL WITH IMPO R TED TO PSO IL. WATER EACH PLANT IMMEDIATELY AFTER PLANTING AND REGULARLY DURING ESTABLISH MENT PERIOD.
EXISTING SUBGRADE
S H R U B P L A N T I N G I NG A R D E N B E D
S ta n d a rd La n d sc a p e D ra w in g s
PLA NTING DETAILS
LD005Update for PDF
Amendments
ARev. Detail
DK 07.07.05
SCA LE: NTSSEPT 2002
DateIni tials DWG :
PAGE 12 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
1.6 Detail of Indicative roundabout planting
NOTE:PR EPAR E AR EAS TO BE PLANTED BY SPRAYING WITH 2 APPLICATIO NS O F R O UND-UP. FO LLO WED BY AN APPLICATION OF GYPSUM AT A R ATE O F 1kg/metre sq. AND THEN BY CULTIVATING TO A DEPTH O F 200mm. SUPPLY AND SPR EAD IMPROVED TOPSOIL TO 75mm BELO W TO P O F KER BS. LIGHTLY COMPACT TOPSOIL. DEPTH O F SO IL WILL VAR Y . SUPPLY AND SPREAD 75mm DEPTH O F F INE BAR K MULCH O VER GAR DEN BED AREAS. SUPPLY AND PLANT ALL TR EES, SH R UBS AND GR O UNDCOVERS ACCORDING TO R ELEVANT DETAILS. WATER EACH PLANT THOROUGHLY AFTER PLANTING.
INDICATIVE TUFTING PLANTS (150mm PO TS) R ATES O F PLANTING PER SQ METRE:Dietes bicolor - 3Kniphof ia cultivars - 3Phormium cultivars - 4Lomandra longifolia - 4
INDICATIVE SH R UBS AND GROUNDCOVERR ATES O F PLANTING PER METRE. SQ:Carpet R ose cultivars - 3Cistus salv iifolius - 2O steospermum cultivars - 3
PLANTING SET BACK 3m FROM EDGE O F R O AD INF ILLED WITH PAVING
I N D I C A T I V E R O U N D A B O U TP L A N T IN G
S ta n d a rd La n d sc a p e D ra w in g s
PLANTING DETAILS
LD006Update for PDF
Amendments
ARev. Detail
DK 07.07.05
SCALE: NTSSEPT 2002
DateInitials DWG :
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 13 TECHNICAL NOTES FOR OPEN SPACE
1.7 Detail of indicative tree planting in roundabout
NOTE:PR EPAR E AR EAS TO BE PLANTED BY SPRAYING WITH 2 APPLICATIO NS O F R O UND-UP. FO LLO WED BY AN APPLICATION OF GYPSUM AT A R ATE O F 1kg/metre sq. AND THEN BY CULTIVATING TO A DEPTH O F 200mm. SUPPLY AND SPR EAD IMPROVED TOPSOIL TO 75mm BELO W TO P O F KER BS. LIGHTLY COMPACT TOPSOIL. DEPTH O F SO IL WILL VAR Y . SUPPLY AND SPREAD 75mm DEPTH O F F INE BAR K MULCH O VER GAR DEN BED AREAS. SUPPLY AND PLANT ALL TR EES, SH R UBS AND GR O UNDCOVERS ACCORDING TO R ELEVANT DETAILS. WATER EACH PLANT THOROUGHLY AFTER PLANTING.
TR EE
PLANTING SET BACK 3m FROM EDGE O F R O AD INF ILLED WITH PAVING
GRO UND CO VER O R GR ANITIC SAND
I N D I C A T I V E T R E E I NR O U N D A B O U T P L A N T I N G
PLANTING DETAILS
LD007Update for PDF
Amendments
ARev. Detail
DK 07.07.05
SCALE: NTSSEPT 2002
DateInitials DWG :
S ta n d a rd La n d sc a p e D ra w in g s
PAGE 14 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
1.8 Detail of grade requirements for planting and access
MAXIMUM PLANTED BANK - 1:2 GRADE
MAXIMUM GR ASSED BANK - 1:4 GRADE
MAXIMUM DISABLED ACCESS (HARD OR SO FT) - 1:12 GRADE
H O R IZO NTAL PLANE - 0:0
GR ADES STEEPER TH AN 1:2 REQUIRE APPR O PR IATE R ETAINING WALLS/ STR UCTURES
R ETAINING WALL
NOMINAL OR IG INAL
GRADE
NEW G
RADE
NOTE:WH ER E UNAVO IDABLE, SLO PE MAY BE BENCH ED. BENCHES ARE TO BE NO MORE THAN 1.2m H IGH AND AT LEAST 2m WIDE, WITH A TO P SET BACK OF AT LEAST 3m.
G R A D E R E Q U I R E M E N T S F O RP L A N T I N G A N D A C C E S S
PLANTING DETAILS
LD008Update for PDF
Amendments
ARev. Detail
DK 07.07.05
SCALE: NTSSEPT 2002
DateInitials DWG :
S ta n d a rd La n d sc a p e D ra w in g s
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 15 TECHNICAL NOTES FOR OPEN SPACE
2 IRRIGATION DETAILS
PAGE 16 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
2.1 Detail of oval irrigation
LAYOU T DEPEND ING ON SPR AYH EAD TYPE, PIPE SIZE AN D WATER VALVE PRESSUR E AN D VELO CITY
AUTO MATIC PO P-UP SPRAYHEAD IRR IGATIO N
Q UICK CO UPLER VALVELO CATIO N FO R TURF WICKETS O NLY
Stand ardsAll m ater ia ls a nd wor km an sh ip s ha ll b e the best of the ir r es pe ctive kind , co mp ly in g to the standards: A.S. 1477 Pa r ts 1 - 6 U .P.V.C. pipes and fittings for p res sur e a ppl ica tions.
A.S. 1462 Me th od s fo r te stin g unplas ticised P.V.C. p ip e fittings.
A.S. 2032 Co de o f Pr ac tice for ins ta ll atio n of P.V.C. pipe s ys te ms.
A.S. 3000 S.A.A. Wiring Rules.
A.S. 2053 U .P.V.C. wire.
A.S. 3147 Wiring.
Water SupplyD ete rmine water sup ply pr ess ure an d flow ra te p rior to un de rtakin g design.
Pro te ctio n Of W or ks And SafetyPro te ct wor ks b y th e er ec tion o f all necessary b ar ri er s an d sa fe ty s ig ns to ma ke trenchwork safe.
Control lerVar io us c on tr ol le rs fro m so lar powered to e le ctro me ch an ic al a re a va il ab le . Controller to be c om pa tible wi th d es ig n de ma nds of valves and s ta tion s. N om in ate co ntro ll er a nd station and p ro gr am ming c yc le . 240 vo lt p ower i s required to o per ate co ntr oll ers.
W ir in g CableAll wir es a re to be P.V.C. or p oly-sh ea th ed gauge 7 /.050, 1 .5 s q.mm b ui ld in g wi re . An in dividu al s ta tion wir e is to be ins ta ll ed fro m each solenoid valve to th e ap pr op riate co ntro ll er l oc ation. The c om mo n wi re s fo r ea ch c on tr ol le r shall be colour c od ed , an d statio n wi re s co de d by colour or n um be r. Al l wi ring d etai ls a re to be included on the 'as la id' dr awings.
W ir e co nn ec tion s ar e to b e ma de with the use of ' Dr y Sp lice ', R ain Bi rd Sna p- Ti te connectors p ro vide d co mp atib le s ea la nt i s us ed or heat shrink c on ne ctor s. Se alan ts tha t diss olve o r me lt P.V.C. s he athing wou ld n ot b e acceptable.
As sh own on the d es ig n plan , sp ar e wi res are to be l eft - ta pe d an d lo op ed in a va lve box.
R is er s mu st b e ch ec ke d to e ns ur e th at there are no l ea ks a nd a ll a re ins ta ll ed to su it the l evel of the g rou nd.
Valve b ox l id s ar e to b e in stal le d fl us h wi th the finishe d s urface.
Irr ig atio n pipe wo rk to be e xc avated to ensure a c over o f 350m m over m ainl in es a nd laterals. T re nc he s ar e to b e th or ou gh ly c ompacted with s elec te d exca va te d to p so il . Sho uld exca vated soil b e fo un d un su itab le to us e as b ac kfil l, s an d filling o f tr en ch es wil l be required.
Whe re s ol id r oc k is e nc ou nter ed during trench e xc avatio n, r eq ue st a n in sp ec tion o f the open tre nc h. Ro ck s ha ll b e me as ur ed in the solid, jointly b etwe en r ep re se ntatives o f th e Irrigation Sub -Con tr ac to r an d th e Su pe rinten dent. No a llowan ce wil l be m ad e fo r over e xcavation.
All p ip e jo in ting is to b e ca rr ie d ou t in accordance with th e ma nu fa ctur er 's r ecommendation.
Valve wir in g is to be tap ed a t th re e (3) metre inter va ls a nd loc ated in th e sa me trench under the p ipe.
The s ys te m is to be tho ro ug hly fl ushed before fitti ng s pr in kler s wh ic h ar e to b e in stal led and set to su it the fin is he d surface.
As-B uilt DrawingPro vide the Cou nc il 's R ep re se ntative with the ins tr uc tion m an ua l an d co py o f th e as-built d ra wing whe n th e sy stem is co mpleted and c om miss io ne d. D ra wing to clea rly show pipe s izes , va lve ty pe s, loc atio ns , fi ttin gs a nd cable r ou te s.
CommissioningTes ting o f th e sy stem wil l be p er fo rmed after c om pletio n of the ins ta ll atio n an d any repairs n ec es sa ry to pu t th e sy stem into pr oper working o rd er . I t is e xtre me ly imp or ta nt tha t any overspray which c an b e el im in ated fro m pa ve d surfaces is a djus te d by PCS s cr ee ns o r if r eq ui red re-position s prinklers.
ValvesAn is olatin g br as s ga te valve a nd d ou ble check valve s ha ll b e in stal le d at the tap ping point.
Valve s sh al l clos ely ma tc h th e re le vant pipe size a nd flo w ra te d es ig na te d. On ly o ne s olenoid valve p er c on tr ol le r statio n sh all be wired.
Valve BoxesAll valve s ar e to b e ho us ed in lo ckab le b oxes of s ufficien t si ze to al lo w th e va lves to be s erviced witho ut d ig ging . Plac e va lve bo xe s on a b rick b as e.
SprinklersAll s pr in kler h ea ds s ha ll h ave a disc harge of water c om pa tible to the p ip e la yo ut a nd d elivery pressure o f th e ta pp in g po in t. Ma ke a djus tm en ts for throw o f in dividu al s pr ay h ea ds p rior to commissioning o f se rvic e an d Pr ac tica l Co mp le tion . Various s pr in ke r ty pe s an d op er atio n ar e available. It is p re fe ra ble th at the o ne b ra nd o f sp rinkler is used thr ou gh ou t th e pr ojec t. Ens ur e th at s prinklers are s et a t he ad to he ad s pa cing s an d compatible s pa cing to fl ow r ates a nd pressure.
RisersEac h po p- up s pr in kler wou ld b e in stalled on a p oly- ar ticu la te d ri se r to p ro vide a n easy means of h eigh t ad ju stme nt. Sch ed ule 80 15m m P.V.C. pipe to be u se d as risers.
Pip eworkCla ss 12 rigid U.P.V.C. s olve nt welde d pipe work wou ld b e us ed for m ainl in e an d la te ra l lines. Class 12 po ly pie to c er ta in g ar de n locations.
All s pr in kler l in es a nd m ains s ha ll b e installed with a m in im um c over o f 350m m. In te rior o f pipes s ha ll b e ke pt fre e fr om d ir t or d eb ris. Open ends of p ip e sh al l be kep t se aled d ur in g th e laying process. Tur n on valve s to e ac h statio n to flu sh l ines out b efor e fi ttin g sp rayheads.
Ins ta ll atio n TestingIns ta ll atio n of the s ys te m sh al l be c om pleted in full c om pl ia nc e wi th the a pp ro pr ia te Australian Sta nd ar ds.
At ea ch s olen oid as se mb ly , wi re o f sufficient l en gth wi ll b e lo op ed to al lo w fo r future m ainten an ce.
O V A L I R R I G A T I O N
S ta n d a rd La n d sc a p e D ra w in g sSEPT 2002SCALE: NTSLD202IRRIGATION DETAILS
Update for PDFARev. Initials
DK
AmendmentsDetail
07.07.05Date DWG :
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 17 TECHNICAL NOTES FOR OPEN SPACE
2.2 Detail of automatic pop-up sprayhead, sprinkler connection.
PO P-UP SPR INKLER TO R O 606's AND 560P,FALCO N 7005's AND 8005's OR SIMILAR H UNTER or R AINBIRD HEADS
AR TICULATED R ISER S FO R BOTH 606'S AND 570P SER IES TO R O SPRINKLER HEADS
P.V.C. TEE OR ELBOW
CLASS 12 U.P.V.C. LATERAL
!"#
F INISH ED SUR FACE - GRASS O R GARDEN
S P R I N K L E R C O N N E C T I O N
S ta n d a rd La n d sc a p e D ra w in g sSEPT 2002SCALE: NTSLD203IRRIGATION DETAILS
Update for PDFARev. Initials
DK
AmendmentsDetail
07.07.05Date DWG :
PAGE 18 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
2.3 Detail of Section of valves and valve box.
390
450
BRICK SHO RING
CO MMO N WIR E TAPED AT 3M CTS.
MAINLINE SUPPLY
CO MMO N WIR E TAPED AT 3 METR E CENTRES
CAR BO N 1419B (OR SIMILAR ) VALVE BOX
GATE VALVE
GR O UND LEVEL
CO NTR O L WIR E TAPED AT 3M CTS.
EXISTING SITE SOIL
PLASTIC LID
S E C T I O N O F V A L V E S A N DV A L V E B O X
S ta n d a rd La n d sc a p e D ra w in g s
IRRIGATION DETAILS
LD201Update for PDF
Amendments
ARev. Detail
DK 07.07.05
SCALE: NTSSEPT 2002
DateInitials DWG :
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 19 TECHNICAL NOTES FOR OPEN SPACE
2.4 irrigated kickabout area construction detail
H Y DR O SEEDED LAWN O R INSTANT TUR F BEING A MIX OF -70% F INE TUR F TYPE R YE VARIETIES X 320% CR EEPING R ED FESCUE10% COUCH
150mm LAYER LIGH TLY R O LLED IMPO R TED TOPSOIL 50/50 MIX O F BLACK SANDY LO AM AND MEDIUM TEXTURED GREY- BR O WN LOAM(PR O VIDE SO IL TEST FO R COUNCIL APPROVAL)
NO MINAL DEPTH O F SELECTED Q UALITY FILL MATERIAL: 150mm O R AS R EQ UIR ED TO ACH IEVE FINAL LEVEL R ELATIVE TO EXISTING LEVEL. SUPPLY SAMPLE OF IMPO R TED TO PSO IL AND PR O PO SED FILL MATERIAL AND SO IL TEST R ESULTS FO R CO UNCIL APPROVAL PRIOR TO O R DER ING . WH ER E PO SSIBLE SALVAGE EXISTING SITE TOP SO IL BY STR IPPING AND STOCKPILING PRIOR TO DEVELO PMENT WORKS
EXISTING SITE SO IL CULTIVATED TO A MINIMUM DEPTH OF 150mm. INCO R PO R ATE GYPSUM AT 1-5kg PER m ².
150
150
TYPICAL PO P-UP SPRINKLERAS APPR O VED BY COUNCIL
fall
ESTABLISH MINIMUM1: 100 GR ADE TO DRAIN
I R R I G A T E D K I C K A B O U TC O N S T R U C T I O N
S ta n d a rd La n d sc a p e D ra w in g s SEPT 2002SCALE: NTSLD204IRRIGATION DETAILS
Update for PDFARev. Initials
DK
AmendmentsDetail
07.07.05Date DWG :
PAGE 20 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
3 PLAYSPACE DESIGN CHECKLIST
3.1 Playspace Design Checklist
See separate document: S5 – Playspace Design Checklist
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 21 TECHNICAL NOTES FOR OPEN SPACE
4 PATH CONSTRUCTION DETAILS
PAGE 22 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
4.1 Detail of granitic gravel path.
75mm LAYER O F GR ANITIC GRAVEL OF CLAY F INES AND SAND PAR TICLES TO 5mm DIA. CAN BE 5% CEMENT STABILISED CO MPACTED TO 95 % M.M.D.D. AND GENTLY CROWNED. ALTER NATIVELY IF ADJACENT GROUND PROFILE H AS CR O SSFALL - FO R M PATH WITH CROSSFALL TO MATCH
SITE SO IL BO XED O UT, TR IMMED AND CO MPACTED TO 95 % M.M.D.D.
WIDTH VARIES
fall
150
f all
EXISTING SITE SO IL / TURF
75mm LAYER O F 20mm F.C.R. CLASS 2 CO MPACTED TO 98 % ( CAN BE CEMENT STABILISED TO 3 %)
150 x 32mm C.C.A. R E-DRIED TR EATED PINE PLINTH
300x75x25mm C.C.A. R E-DR IED TR EATED PINE CH ISEL PO INT PEGS F IXED TO PLINTH AT 1800mm C/C AND AT CH ANGES O F DIRECTION. F IXED WITH 2 NO . TWISTED SHANK GALVANISED NAILS, SKEW DRIVEN
D E T A I L O F G R A N I T I CG R A V E L P A T H
S ta n d a rd La n d sc a p e D ra w in g s SEPT 2002SCALE: NTSLD101SURFACE DETAILS
Update for PDFARev. Initials
DK
AmendmentsDetail
07.07.05Date DWG :
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 23 TECHNICAL NOTES FOR OPEN SPACE
4.2 Detail of asphalt footpath with brick swale.
BR ICK BANDING TO F INISH FLUSH WITH ADJOINING SURFACE
50-75mm 25MPA CO NCR ETE WITH 45°H AUNCH 30mm H IGH O N END FACE
TR IMMED & CO MPACTED SUBGRADE TO 95 % M.M.D.D. F ILL ANY SOFT SPO TS WITH CLASS 2 F .C.R . AS 150mm SEPARATE LAYERS
100mm CO MPACTED LAYER CLASS 2 F.C.R.
50mm CO MPACTED LAYER CLASS 2 F.C.R.
25mm CO MPACTED LAYER CLASS L ASPHALT SIZE 7
5010
03050
100
25
345
7
3 R O WS 230x114x50mm SELECTED CLAY BRICK PAVERS BUTT-JO INTED IN STR ETCH ER CO UR SE LAID IN MORTAR BED. FO R M CH ANNEL WITH END CO UR SES ON SMALL ANGLE.
7mm LAYER PR IMER BINDER
fall
B R I C K S W A L EA S P H A L T F O O T P A T H W I T H
AmendmentsRev.A Update for PDF
Detail
SCALE: NTSSEPT 2002
07.07.05InitialsDK
DateSURFACE DETAILS
LD102DWG :
S ta n d a rd La n d sc a p e D ra w in g s
PAGE 24 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
4.3 Detail of coloured concrete paving with tile banding.
40
150
50
EXISTING SITE SO IL TR IMMED AND CO MPACTED TO 95 % M.M.D.D. EXCAVATE SO IL/CLAY TO ANY SO FT SPOTS AND REPLACE WITH CLASS 2 F .C.R . AS 150mm COMPACTED LAYER S WITH 3 % CEMENT STABILISATION TO EACH LAYER
75mm LAYER CLASS 2 F .C.R. COMPACTED TO 95% M.M.D.D.
150mm TH ICK 25MPa COLOURED CO NCR ETE F72 R EINFO R CEMENT WITH 50mm CO VER FR O M TO P OF CONCRETE. COLOUR AS R EQ UIRED. BRO OM F INISHED.
CO NCR ETE TO BE CUR ED FOR AT LEAST SEVENTY-TWO (72) HOURS CO NTINUO USLY , FO LLO WING THE TIME OF PLACEMENT.
JO INT SPACING R EQUIREMENTS: CO NSTR UCTIO N JO INTS - AT MAXIMUM 15m SPACINGSAWCUT JO INTS - AT MAXIMUM 5m SPACINGEXPANSIO N JO INTS - AT JUNCTIONS TO BUILDINGS AND STRUCTURES
20 - 30 1:3 CEMENT SAND - MIX WET
SELECTED MASO NR Y PAVING TILE. WET UNDER SIDE O F PAVERS IMMEDIATELY PR IO R TO LAYING. NO TE: CO NSTR UCT DR AINAGE PITS CLO SE TO EDGE O F CONCRETE SUR FACE O R WITH IN CONCRETE SUR FACE.ESTABLISH POSITIVE
GR ADIENT, WHEREVER POSSIBLE FO R DR AINAGE.
fall
30
W I T H T I L E B A N D I N GC O L O U R E D C O N C R E T E P A V I N G
AmendmentsRev.A Update for PDF
Detail
SCALE: NTSSEPT 2002
07.07.05InitialsDK
DateSURFACE DETAILS
LD104DWG :
S ta n d a rd La n d sc a p e D ra w in g s
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 25 TECHNICAL NOTES FOR OPEN SPACE
4.4 Detail of reserve path, shared foot/bicycle path.
B I C Y C L E / F O O T P A T HR E S E R V E P A T H , S H A R E D
AmendmentsRev.A Update for PDF
Detail
SCALE: NTS
SEPT 2002
07.07.05Init ialsDK
DateSURFACE DETAILS
LD103DWG :
S ta n d a rd La n d sc a p e D ra w in g s
PAGE 26 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
5 BOLLARD AND FENCING DETAILS
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 27 TECHNICAL NOTES FOR OPEN SPACE
5.1 Detail of timber post & rail barrier
100 x 75mm TREATED TIMBER RAILSCLEARANCE FROM GROUND LEVEL : 700mm
HOLES DRILLED THROUGH CENTRE POSTS ONLY PART DRILL HOLES AT END POSTS
GROUND LINE
REMOVEABLE BOLLARD
125x125x1000mm HIGH TREATED PINE TIMBER BOLLARDS
2800OPENING FOR PEDESTRIAN AND VEHICULAR ACCESS
1800
7001000
600mm INTO GROUND WITH A MIN IMUM OF 100mm CEMENT STABILISED BACKFILL COVER TO ALL SIDES
R A I L B A R R I E RT I M B E R P O S T A N D
AmendmentsRev.A Update for PDF
Detail
SCALE: NTSSEPT 2002
07.07.05InitialsDK
DateFENCING DETAILS
LD301DWG :
S ta n d a rd La n d sc a p e D ra w in g s
PAGE 28 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
5.2 Detail of timber post & steel rail barrier
75mm Ø GALVANIZED STEEL PIPECLEARANCE FROM GROUND LEVEL : 700mm
HOLES DRILLED THROUGH CENTRE POSTS ONLY PART DRILL HOLES AT END POSTS
GROUND LINE
REMOVEABLE BOLLARD
125x125x1000mm HIGH TREATED PINE TIMBER BOLLARDS
2800OPENING FOR PEDESTRIAN AND VEHICULAR ACCESS
1800
7001000
600mm INTO GROUND WITH A MIN IMUM OF 100mm CEMENT STABILISED BACKFILL COVER TO ALL SIDES
T I M B E R P O S T A N DS T E E L R A I L B A R R I E R
DWG :
LD302FENCING DETAILS
SEPT 2002SCALE: NTS
AmendmentsDetailRev.
Update for PDFADateInitials07.07.05DK
S ta n d a rd La n d sc a p e D ra w in g s
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 29 TECHNICAL NOTES FOR OPEN SPACE
5.3 Detail of gable end bollard
350
150
600620
80 125
150
1000
60
BO LLAR DS TO BE INSTALLED 600mmINTO GR O UND WITH A MINIMUM O F 100mm CEMENT STABILISED BACKFILL COVER TO ALL SIDES.
EXISITNG SITE SOIL CO MPACTED TO A DEPTH O F 80mm
150 X 125 X 1000mm H IGH TR EATED PINE TIMBER BO LLARD FR EE O F KNOTS AND SPLITS - SPACED AT 1400mm CENTRES
GR O UND LINE
PLAN VIEW O F 'GABLE' END
INSER T 150mm BRIDGE SPIKE50mm INTO POST
G A B L E E N D B O L L A R DDWG :
LD303FENCING DETAILS
SEPT 2002SCALE: NTS
AmendmentsDetailRev.
Update for PDFADateInitials07.07.05DK
S ta n d a rd La n d sc a p e D ra w in g s
PAGE 30 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
5.4 Detail of bevel end bollard
PLAN VIEWO F 'BEVEL' END
1000mm H IGH TR EATED PINE BO LLAR D FREE OF KNO TS AND SPLITS - SPACED AT 1400mm CENTRES.
GR O UND LINEEXISITNG SITE SOIL CO MPACTED TO A DEPTH O F 80mm
BO LLAR DS TO BE INSTALLED 600mm INTO GR O UND WITH A MINIMUM O F 100mm CEMENT STABILISED BACKFILL COVER TO ALL SIDES.
350150
600620
80
1000
150150
150
INSER T 150mm BR IDGE SPIKE 50mm INTO POST.
S ta n d a rd La n d sc a p e D ra w in g s
B E V E L E N D B O L L A R DDWG :
LD305FENCING DETAILS
SEPT 2002SCALE: NTS
AmendmentsDetailRev.
Update for PDFADateInitials07.07.05DK
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 31 TECHNICAL NOTES FOR OPEN SPACE
5.5 Detail of gable end bollard with recess.
350
150
600620
80 125
150
18
18
1000
60
150
BO LLAR DS TO BE INSTALLED 600mmINTO GR O UND WITH A MINIMUM O F 100mm CEMENT STABILISED BACKFILL COVER TO ALL SIDES.
EXISITNG SITE SOIL CO MPACTED TO A DEPTH O F 80mm
150 X 125 X 1000mm H IGH TR EATED PINE TIMBER BO LLARD FR EE O F KNOTS AND SPLITS - SPACED AT 1400mm CENTRES
GR O UND LINE
FOR M R EBATE AS DETAILED
PLAN VIEW O F 'GABLE' END
R EBATE DETAIL
INSER T 150mm BRIDGE SPIKE50mm INTO POST
S ta n d a rd La n d sc a p e D ra w in g s
G A B L E E N D B O L L A R DW I T H R E C E S S
DWG :
LD304FENCING DETAILS
SEPT 2002SCALE: NTS
AmendmentsDetailRev.
Update for PDFADateInitials07.07.05DK
PAGE 32 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
5.6 Detail of removable bollard and square options
TIMBER , PO WDER COATED or GALVANISED STEEL BOLLARD OF VAR YING SIZES
GR O UND LINE
EYE BO LT AND PADLOCK
MS CH ECKPLATE WITH SLO T FO R EYE BOLT, ATTACH ED TO SLEEVE BY H INGE AT BASE
MS SLEEVE WITH 125 x 125 x OR 125 DIA. INTER NAL DIMENSIONS
BASE O F PO ST 120 x 120 O R 120mm DIA.
CO NCR ETE FO O TING - MINIMUM 150mm FR O M ALL SIDES LAR GE DR AINAGE H O LE AT BASE
PLATE
SCR EENINGS
NO TE: Maintain drainage hole in base plate.
140-150
350
50
300
60
420 min
S ta n d a rd La n d sc a p e D ra w in g s
R E M O V E A B L E B O L L A R D , R O U N DA N D S Q U A R E O P T I O N S
DWG :
LD306FENCING DETAILS
SEPT 2002SCALE: NTS
AmendmentsDetailRev.
Update for PDFADateInitials07.07.05DK
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 33 TECHNICAL NOTES FOR OPEN SPACE
6 PARK FURNITURE DETAILS
PAGE 34 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
6.1 Detail of timber slat bench.
610
FIXING: BO LTS F IXED TO CO NCRETE PAD.BO LT DETAIL - 4 No. M8 X 65MM ZINC PLATED DYNABOLTS.TAMPER PR O O FING DYNABO LTS - BURRING OFF THREADED TOP.CO NCR ETE PAD 2000x1200 WIDE x 125mm THICK
1800
60x30mm TIMBER, ALUMINIUM, MILD STEEL OR STAINLESS STEEL SLATS
MILD STEEL 40x5MM BRACING BAR
CAST ALUMINIUM END FRAMES
AR M R ESTSMS 40x10mm BAR
NO TE
FINISH : CAST ALUMINIUM - PO WDER CO ATED TO CO LO UR APPROVED BY COUNCIL TIMBER - O ILED O R STAINED FINISHMILD STEEL - GALVANISED AND PO WDER CO ATED TO APPROVED SELECTED COLOUR
S ta n d a rd La n d sc a p e D ra w in g s
S L A T B E N C H S E A TDWG :
LD401FURNITURE DETAILS
SEPT 2002SCALE: NTS
AmendmentsDetailRev.
Update for PDFADateInitials07.07.05DK
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 35 TECHNICAL NOTES FOR OPEN SPACE
6.2 Detail of metal bench seat.
F IXING: BO LTS F IXED TO CO NCRETE PAD.BO LT DETAIL - 4 No. M8 X 65MM ZINC PLATED DYNABOLTS.TAMPER PR O O FING DYNABO LTS - BURRING OFF THREADED TOP.CO NCR ETE PAD 2000x1200 WIDE x 125mm THICK
INF ILLS 60x30mmMILD STEEL
UPR IGHTSMS 60x60 SHS
NO TE
FINISH : MILD STEEL - GALVANISED AND PO WDER CO ATED TO APPROVED SELECTED COLOUR
870
1800
610
DK 07.07.05Initials Date
A Update for PDFRev. Detail
Amendments
SCALE: NTSSEPT 2002
FURNITURE DETAILS
LD402DWG :
M E T A L B E N C H S E A T
S ta n d a rd La n d sc a p e D ra w in g s
PAGE 36 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
6.3 Detail of picnic table with attached seats.
GR O UND LINE
1800 x 1300 x 720mm H AR DWO O D TIMBER, POWDER CO ATED STEEL O R STAINLESS STEEL AND STEEL FR AME PICNIC TABLE
FIXINGTIMBER S TO FR AME - R EAR F IXED WITH M6 ZINC PLATED, TAMPER PROOF, HEX HEAD SCREWSWELD STEEL SLATS TO FRAME
PICNIC SETTING TO GROUND - 1. BASE PLATE - MILD STEEL PLATE F IXED TO CO NCR ETE PAD - 400x400x10mm PLATE DR ILLED WITH 4 No. 17mm DIA. BOLT HOLESBO LTS - 4 M16 GALV. DYNABOLTS OR RAG BOLTSTAMPER PR O O F DYNABO LTS - BURRING OFF THREADED TOP2. DIR ECT BUR Y - EXTEND LEG 1000mm, WELD R O D ANCH O R TO BASE AND BURY DIRECTLY INTO PLACE
1800
1320
750
A T T A C H E D S E A T SP I C N I C T A B L E W I T H
Amendments
A Update for PDFRev. Detail
SCALE: NTSSEPT 2002
FURNITURE DETAILS
LD403DK 07.07.05DateInitials DWG :
S ta n d a rd La n d sc a p e D ra w in g s
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 37 TECHNICAL NOTES FOR OPEN SPACE
6.4 Detail of picnic table with non-attached seats.
370 600 370100100 100 100
1200
1200
750
430
450
PR O VIDE 5mm CH AMFER TO ALL WOODWORK
200x50 R EDGUM ALL BO AR DS TO BE FREE OF ROUGH EDGES AND SPLINTERS2 No. 10mm CO ACH BOLTS PER CO NNECTION
100x100mm R EDGUM PO STS SET 450mm INTO 5% CEMENT STABILISED BACKFILL
100x100mm R EDGUM POST
100x50mm R EDGUM
GR O UND LINE
PLAN SECTION250 700 250
400
SEATS O N 3 SIDES O NLY VACANT SIDE FOR WHEELCH AIR ACCESS. PROVIDE ACCESS FROM NEAR EST PATH
S ta n d a rd La n d sc a p e D ra w in g s
DWG :
LD404FURNITURE DETAILS
SEPT 2002SCALE: NTS
T I M B E R P I C N I C T A B L E W I T HN O N - A T T A C H E D S E A T S
07.07.05DKUpdate for PDFADetailRev.
AmendmentsInitials Date
PAGE 38 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
6.5 Detail of table and seat fixing.
20MPa CO NCR ETE FOOTING
16mm DIA. GALVANISED R O DS ON BOTH SIDES O F TUBE WELDED TO PO ST - HOT DIP GALVANISE AFTER FABRICATION
8mm DIA.TH R EADED GRUB SCREW
30mm CO MPACTED LAYER TYPE L ASPH ALT SIZE 10 / O R MATCH TO SUR R O UNDING FINISH
20mm SQ UAR E TUBE - UNDER SIDE SET FLUSH WITH GR O UND LEVEL
76mm EXTER NAL DIA. , 65mm INTERNAL DIA. GALVANISED TUBE WITH 5mm MACH INE BEVELLED EDGE AT TOP
PO ST O F SEAT/TABLE
210
310
20 100
450
550
DWG :
LD405FURNITURE DETAILS
SEPT 2002SCALE: NTS
T A B L E A N D S E A TF I X I N G D E T A I L
07.07.05DKUpdate for PDFADetailRev.
AmendmentsInitials Date
S ta n d a rd La n d sc a p e D ra w in g s
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 39 TECHNICAL NOTES FOR OPEN SPACE
6.6 Detail of drinking fountain – standard.
850
220
150
370
STAINLESS STEEL BUBBLER AND BOWL
STAINLESS STEEL BODY
FLEXIBLE STAINLESS STEEL PIPE
CO NNECT TO WATER SUPPLY
300mm DIAMETER BASE PLATE BOLTED TO PAVING WITH 4No. 10 O R 12mm M.S. BOLTS
PO SITIO N O N 1000x1000x100mm TH ICK CO NCR ETE PAVING SLAB F72 MESH PLACED CENTRALLY
DWG :
LD406FURNITURE DETAILS
SEPT 2002SCALE: NTS
D R I N K I N G F O U N T A I N 07.07.05DKUpdate for PDFADetailRev.
AmendmentsInitials Date
S ta n d a rd La n d sc a p e D ra w in g s
PAGE 40 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
6.7 Detail of drinking fountain – accessible
STAINLESS STEEL BUBBLER
STAINLESS STEEL BODY
870
770
300 X 300mm GALV. STEEL MO UNTING PLATE BO LTED WITH 4No. (DIM)M.S. BO LTS TO PAVING OR FOOTING.
GR O UND LEVEL
MIN. 650
MIN. 500
FLEXIBLE STAINLESS STEEL PIPE
CO NNECT TO WATER SUPPLYPO SITIO N O N 1000x1000x100mm TH ICK CO NCR ETE PAVING SLAB F72 MESH PLACED CENTRALLY
S ta n d a rd La n d sc a p e D ra w in g s
DWG :
LD407FURNITURE DETAILS
SEPT 2002SCALE: NTS
D R I N K I N G F O U N T A I NA C C E S S I B L E
07.07.05DKUpdate for PDFADetailRev.
AmendmentsInitials Date
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 41 TECHNICAL NOTES FOR OPEN SPACE
6.8 Detail of rubbish bin enclosure.
SIDE ENTR Y PUNCH ED PER FORATED CAST ALLUMINIUM SH EET 120 O R 80 LITRE CAPACITY BIN SURROUNDPO WDER CO ATED - CO LO UR TO COUNCIL APPR OVALGALVANISED STEEL SOCKETLO CKABLE DOOR ENTRY
120 O R 240 LITRE PLASTIC WH EELED BIN
GR O UND LINE
300X300X450mm CO NCR ETE FOO TING
PLACEMENT O F BIN:- AVO ID CORNERS- WH ER E PO SSIBLE, PLACE NEAR POLES - 500mm MINIMUM DISTANCE FROM KERB-5m MINIMUM DISTANCE FROM SEATS- DO O R TO O PEN PAR ALLEL/ OPEN TO KERB
PEAKED STAINLESS STEEL ENTR Y LID FO R R ECYCLE BIN
1165
43-9
0
450
DWG :
LD408FURNITURE DETAILS
SEPT 2002SCALE: NTS
R U B B I S H B I NE N C L O S U R E
07.07.05DKUpdate for PDFADetailRev.
AmendmentsInitials Date
S ta n d a rd La n d sc a p e D ra w in g s
PAGE 42 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
6.9 Detail of rubbish bin security posts.
SUITABLE FO R 120 AND 240 LITR E PLASTIC WH EELED BINS
GR O UND LINE
1110mm H IGH SINGLE OR DOUBLE, LO CKED, GALVANISED STEEL SECUR ITY POSTSPO WDER CO ATED - COLOUR TO CO UNCIL APPROVAL
FIXING:O PTIO NAL 300 X 300 X 8mm BASE PLATE BO LTED DO WN TO PAVED SUR FACE O R PO ST SET IN 400X300X300mm CO NCR ETE FOOTING AND 1500x1000x100mm DEEP CO NCR ETE PAD
WH ER E BIN IS SITUATED WITH IN GR ASSED AREA, CO NSTR UCT CO NCR ETE PAD TO ALLO W FOR MOWING AR O UND BIN
300
400
100
DWG :
LD409FURNITURE DETAILS
SEPT 2002SCALE: NTS
R U B B I S H B I N W I T HS E C U R I T Y P O S T
07.07.05DKUpdate for PDFADetailRev.
AmendmentsInitials Date
S ta n d a rd La n d sc a p e D ra w in g s
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 43 TECHNICAL NOTES FOR OPEN SPACE
6.10 Detail of bike rack and footings.
810mm H IGH X 50.8mm DIAMETER STAINLESS STEEL TUBE WITH POLISHED O R PO WDER CO ATED F INISH - COLOUR TO CO UNCIL APROVAL 450mm R ADIUS
STEEL TUBE STIFFENER
150X150X5mm STEEL PLATE ANCH O R ED 300mm FR O M GR O UND LEVEL INTO FOOTING
350 X 350 X 350mm CO NCR ETE FOOTING
PAVING , CO NCRETE OR ASPH ALT SURFACE
ALTER NATIVE FIXING:- 50mm DYNA BO LT / 10 mm DYNA BOLTS WITH NUTS TACK WELDED FO R SECURITY THROUGH 150X150X5mm STEEL BASE PLATE INTO GROUND
PLACEMENT:- PO SITIO N PAR ALLEL TO TR EE GRILLS AND PER PENDICULAR TO KER B WHERE POSSIBLE- SPACE AT MINIMUM 1000mm APART- PO SITIO N MINIMUM DISTANCE O F 1000mm FROM SEATING
950350
350300
300
810
S ta n d a rd La n d sc a p e D ra w in g s
DWG :
LD410FURNITURE DETAILS
SEPT 2002SCALE: NTS
B I K E R A C KA N D F O O T I N G S
07.07.05DKUpdate for PDFADetailRev.
AmendmentsInitials Date
PAGE 44 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
6.11 Detail of reserve pole light.
LANTER N (eg. BO URKE HILL, NO STALG IA O R KENSINGTON SER IES) WITH INTEGRAL P.E. CELLS AS PER AS3771
ACCESS DO OR
IN-GR O UND FIXING
LANTER N AND POLE UNIFO R M IN COLOUR(eg. BLACK, CLARET RED, H AWTH OR N GR EEN)
NOTE:LANTER NS MUST CO NFO RM WITH THE VESI GUIDELINES FO R NON-STANDARD PUBLIC LIGH TING AND BE UNIFORM TH R O UGH O UT THE ESTATE
5500
S ta n d a rd La n d sc a p e D ra w in g s
DWG :
LD411FURNITURE DETAILS
SEPT 2002SCALE: NTS
R E S E R V E L I G H TP O L E
07.07.05DKUpdate for PDFADetailRev.
AmendmentsInitials Date
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 45 TECHNICAL NOTES FOR OPEN SPACE
6.12 Detail of Electric BBQ unit.
UNDER SIDE O F LINTEL 100X10 M.S. GALV.
240V 6 KW PUSH BUTTO N O PERATED BBQ
MO NIER UNI-PAVE BUTTED TO BRICK COURSE
R EINFO R CED CO NCRETE F72 R EINFO R CING MESH
BRICKWO RK O PENINGVENTILATE BRICKWO RK
100mm DIA. R .G . DRAIN PIPE
CO NCEAL PIPE IN BR ICKWO RK OR BLUESTONE
SPR ING LO ADED SELF CLOSING TAP
150mm R EINFO R CED CONCRETE SUSPENDED SLAB
CO NCR ETE SLAB FOOTING 150mm TH ICK F72
STAINLESS STEEL H O T PLATES SET ON TOP OF BENCH TO P IN ACCO R DANCE WITH MANUFACTURERS SPECIF ICATIO NS. PR O VIDE TWO PUSH BUTTON O PER ATED ELECTR IC BAR BEQ UES TO EACH UNIT.
GATIC L500 PIT GR ATE. BRICK PIT AND CO NCR ETE BASE
CO NCR ETE FO O TING , BRICK PAVERS O R GR ANITIC GR AVEL SURFACE - 1000mm WIDE STANDING AREA ON ALL SIDES. ALLO W 30mm FALL FROM TAP TO PIT.
GATIC L500 PIT GRATE. BR ICK PIT WITHIN CO NCR ETE BASE
STAINLESS STEEL BENCHTOP (SINGLE O R DO UBLE INSERTS)
PLAN
ELEVATION
S ta n d a rd La n d sc a p e D ra w in g s
DWG :
LD412FURNITURE DETAILS
SEPT 2002SCALE: NTS
E L E C T R I C B B Q U N I T 07.07.05DKUpdate for PDFADetailRev.
AmendmentsInitials Date
PAGE 46 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
7 SIGNAGE GUIDELINES 7.1 Formatting
7.1.1 Colour All Hume City Council signs are to follow colour and type specifications. The logo is to appear in only two formats:
1. On a white background using Black and Blue PMS 2728.
2. On a green background, the logo will appear in two colours: black and blue. On a blue background, the logo will be reversed out in white.
Background colour of Heading area is to be solid blue strip to match PMS 2728 as shown above. Bottom strip to be green to match PMS 376. 7.1.2 Font Text is always to be Swiss 721 BT as depicted unless otherwise approved. 7.1.3 Heading Heading text is to be centred on the panel and always appear white reversed out of blue background. The exception to this rule is Sh1 (Shopping Centre Sign) where the blue field is increased to incorporate the title of the Shopping precinct, and the text is left justified. 7.1.4 Information Area The white field is set according to the proportions given in this document. 7.1.5 Bottom Strip The green strip will incorporate by-lines and the Hume City Council logo as required by each sign type.
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 47 TECHNICAL NOTES FOR OPEN SPACE
7.2 Detail of facility name signage
7.2.1 Uses Reserve entrances. Entrance to kindergartens, libraries, community centres. 7.2.2 Locations As close to entrance as possible. To be located in soft earth. 7.2.3 Construction notes Signs fabricated from aluminium with 50mm return to sides. 50mm SHS posts.
PAGE 48 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
7.3 Detail of interpretation signage
7.3.1 Uses To signify points of interest. Wording of ‘Points of Interest’ to be replaced by title of area or feature. 7.3.2 Locations To be situated within 2m of point of interest or at entrance to site. 7.3.3 Construction notes Signs fabricated from aluminium with 50mm return to sides. Painted finish. Anti-graffiti finish may be required. 50mm SHS posts powedercoated to match silver PMS 877. Height ‘X’ to be determined by information to be displayed.
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 49 TECHNICAL NOTES FOR OPEN SPACE
7.4 Detail of gateway signage
7.4.1 Uses G1 - At major roadway entrances to Hume City, generally in a rural setting. G2 – At minor roadway entrances to Hume City, or at major roadway entrances in a highly urbanised setting. 7.4.2 Locations G1 - To be determined on site having regard to visibility and traffic safety requirements G2 – Within 1m of kerb. 7.4.3 Construction notes Signs fabricated from aluminium with 50mm return to sides. 90mm SHS posts on G1, 50mm SHS on G2.
PAGE 50 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
7.5 Detail of suburb signage
7.5.1 Uses S1 – To signify townships within Hume City. S2 –At entrances to suburbs in urban settings within Hume City. 7.5.2 Locations S1 – Semi-rural settings within one metre of kerb, facing direction of traffic S2 – To be determined on site having regard to visibility and traffic safety requirements. Sh1 – At entrances to shopping precincts 7.5.3 Construction notes Aluminium panels with 50mm returns. 90mm SHS posts on S1, Sh1, 50mm SHS on S2.
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 51 TECHNICAL NOTES FOR OPEN SPACE
8 SHELTERS AND GAZEBOS
PAGE 52 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
8.1 Detail of hexagonal picnic pavilion.
CO NCR ETE FO O TINGS AS DESIGNED BY ENGINEER
CO LO UR BO ND CUSTOM ORB ROOF AND FLASHINGS
R OO F PITCH 28 °
GR O UND
2205
5600
2800
2200
PLAN VIEW
ELEVATION
LEVEL
PO WDER CO ATED ALL STEEL CO NSTR UCTIO N. POSTS SET INTO CO NCR ETE FOOTING.
ANTI-GR AFFITI CO ATING TO ALL EXPO SED SURFACES
CO LO R BOND GUTTER
DO WNPIPES CO NNECT TO LEGAL POINT O F DISCHARGE
DP
DP
WH ER E LIGH TING IS R EQ UIR ED, INSTALL INTO APEX A 'PIERLITE' VO 2118 WITH TWIN 18W FLO UR O TUBES AND OPAL PO LYCAR BO NATE DIFFUSER , CO NTROLLED WITH PE CELL.CIR CUIT TO BE R CD PR O TECTED AND WIRING TO RUN THROUGH GALVANISED STEEL CONDUIT.
NOTE:BUILDING PER MIT IS R EQUIRED AND MUST BE SUPPLIED TO CO UNCIL AT H ANDO VER
S ta n d a rd La n d sc a p e D ra w in g s
DWG :
LD501STRUCTURE DETAILS
SEPT 2002SCALE: NTS
H E X A G O N A L P I C N I CP A V I L L I O N
07.07.05DKUpdate for PDFADetailRev.
AmendmentsInitials Date
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 53 TECHNICAL NOTES FOR OPEN SPACE
8.2 Detail of square picnic pavilion
R O O F PITCH 34 DEGREES
PO WDER CO ATED ALL STEEL CO NSTR UCTIO N. POSTS SET INTO CO NCR ETE FOOTING.
ANTI-GR AFFITI CO ATING TO ALL EXPO SED SURFACES
CO LO UR BO ND CUSTOM ORB R OO F AND FLASHINGS
PLAN VIEW
ELEVATION
GR O UND LEVEL
4000
220031
00
DP
DP
DO WNPIPES CONNECTTO LEGAL POINT OFDISCH AR GE
CO LO R BOND GUTTERING
CO NCR ETE FO O TINGS AS DESIGNED BY ENGINEER
WH ER E LIGH TING IS R EQ UIR ED, INSTALL INTO APEX A 'PIERLITE' VO2118 WITH TWIN 18W FLO UR O TUBES AND O PAL POLYCARBONATE DIFFUSER, CO NTR O LLED WITH PE CELL.CIR CUIT TO BE R CD PR O TECTED AND WIRING TO RUN THROUGH GALVANISED STEEL CONDUIT.
NOTE:BUILDING PER MIT IS R EQUIRED AND MUST BE SUPPLIED TO CO UNCIL AT H ANDO VER
DateInitialsAmendments
Rev. DetailA Update for PDF DK 07.07.05
P A V I L L I O NS Q U A R E P I C N I C
SCALE: NTSSEPT 2002
STRUCTURE DETAILS
LD502DWG :
S ta n d a rd La n d sc a p e D ra w in g s
PAGE 54 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
9 WATER FEATURES AND WETLAND DETAILS
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 55 TECHNICAL NOTES FOR OPEN SPACE
9.1 Detail of stormwater outlet for large diameter pipes
LAR GER TO E RO CKS TO BE 1000-1200mm DIAMETER
CO NCR ETE CR ADLE 25mpa IF R EQ UIR ED. O TH ERWISE NORMAL CR USH ED R O CK/ CONCRETE SLUR R Y PIPE BEDDING IS ACCEPTABLE
F81 MESH CENTR ALLY LOCATED
FIR M SITE SOIL BASE
NOTE:ANGLE PIPE 45° DO WNSTREAM ANY DISTUR BED AR EA O F EXISTING EMBANKMENT R ESULTING FR O M TH E WORKS IS TO BE PLANTED WITH SUITABLE VEGETATION
SMALLER BANK ROCKS TO BE 800 - 1000mm DIAMETER
PIPEDIAMETER NO MINAL
STABILISE ALL R OCKS WITH CO NCR ETE SLUR R Y TO VOID SPACES AND BASE.
EXTEND R O CK OVER EDGE O F PIPE TO HIDE O UTLET
VO IDS BETWEEN R O CKS ON SIDE OF EMBANKMENTS TO BE F ILLED WITH TOP SO IL AND APPR O PR IATE PLANTS (INDIGENOUS)
VO IDS TO BASE O F STREAM FILLED WITH CO NCR ETE TO ENSURE WATER FLO WS O VER AND AROUND ROCKS AND NO T UNDER NEATH
VAR IES DEPENDING O N SITE CO NDITIONS
DateInitialsAmendments
Rev. DetailA Update for PDF DK 07.07.05
L A R G E D I A M E T E R P I P E SS T O R M W A T E R O U T L E T F O R
SCALE: NTSSEPT 2002
WATER FEATURES
LD601DWG :
S ta n d a rd La n d sc a p e D ra w in g s
PAGE 56 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
9.2 Detail of ephemeral pond & settling pond
TYPICAL OUTFLOW PIPE FROM STREET DRA IN, EA SEMENTS OR OPEN SPA CE
ROCK RIPPLE BUFFER TREATMENT - ROCKS TO BE OF VARYING SIZES WITHIN A 300 - 500mm DIA METER SIZE RANGE
SEDIM ENT FIRST FLUSH SETTLING POND FILLED WITH CRUSHED ROCK BALLA ST A ND RANGE OF RIVER PEBBLES -- MA XIMUM 50mm DIA METER
PLA NTING OF REEDS A ND RUSHES IN POND AND A LONG M EA NDERING FILTRATION BED EG: CA REX SPP. , ELEOCHA RIS SPP.
PLAN VIEW
SECTION VIEWHIGH WA TER LEVEL
GROUND LEVEL
NOTE:SUPPLY MAINTENANCE/MANAGEMENT PLAN DETAILING WATER Q UALITY TESTING R EQ UIR EMENTS, SILT AND VEGETATION MANAGEMENT SCH EDULES
CHA NNEL TO MOAT A ND/OR FUTHER FILTRATION SYSTEM
SPORTS TURF GRA SSES, LOMA NDRA, CAREX OR JUNCUS
M AXIM UM 1:6 GRA DE INTO POND
HIGH WA TER LEVEL
EPHEMERAL POND
SETTLING POND
S ta n d a rd La n d sc a p e D ra w in g s
E P H E M E R A L A N DS E T T L I N G P O N D
DWG :
LD602WATER FEATURES
SEPT 2002SCALE: NTS
07.07.05DKUpdate for PDFA
AmendmentsRev. Detail Initials Date
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 57 TECHNICAL NOTES FOR OPEN SPACE
9.3 Detail of Permanent Ornamental Pond.
MINIMUM 2 METR E BUFFER PLANTING TO EMBANKMENT - MAXIMUM WATER DEPTH 300mm. USE O F CAREX, ELEOCHARIS, AMPHR IBRO MUS, ISO LEPIS SPECIES AND TO DRIER SLO PES: LO MANDR A, DIANELLA, POA AND DANTH O NA SPECIES.
WATER LEVEL AT CAPACITY
WH ER E SPACE PER MITS IN LARGER PO NDS, CR EATE DEEPER TROUGHS AS F ISH H ABITATS AND TO ESTABLISH GR EATER WATER MOVEMENT.
TROUGH
WH ER E SPACE PER MITS IN LARGER PO NDS, CR EATE R EFUGE ISLANDS.
GR O UND LEVEL
IF NECESSAR Y CR EATE MOAT F ILTR ATIO N SYSTEM AROUND EDGE O F PO ND. PLANT SPECIES AS PER BUFFER PLANTING.
BUFFER PLANTING - CAN BE CO MBINED WITH A MOAT F ILTR ATIO N SYSTEM AROUND THE PO ND
D EEP TR OUGH
D EEP TR OUGH
D EEP TR OUGH
ISLAND
H EADWALL AND INLET FROM STO R MWATER SYSTEM, STREET DR AINS, EASEMENTS OR OPEN SPACE
FLO W OF WATER THR OUGH MO AT F ILTR ATIO N SYSTEM IF APPLICABLE
EDGE OF POND
EDGE OF BUFFER PLANTING OR MOAT
TROUGH
PLAN VIEW
SECTION VIEW
NOTE:SUPPLY MAINTENANCE/MANAGEMENT PLAN, DETAILING WATER Q UALITY TESTING R EQ UIR EMENTS, SILT AND VEGETATIO N MANAGEMENT SCHEDULES.
PR O VIDE O VER FLOW OUTLET IN LO CATIO N AS DETERMINED O N SITE
S ta n d a rd La n d sc a p e D ra w in g s
P E R M A N E N T O R N A M E N T A LP O N D
DWG :
LD603WATER FEATURES
SEPT 2002SCALE: NTS
07.07.05DKUpdate for PDFA
AmendmentsRev. Detail Initials Date
PAGE 58 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
10 RECOMMENDED SPECIES LIST See separate document: S5b - Species Lists
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 59 TECHNICAL NOTES FOR OPEN SPACE
11 GUIDE TO REVEGETATION IN HUME WITH INDIGENOUS SPECIES See separate document: S5b - Species Lists
PAGE 60 OCTOBER 2003 HUME CITY DESIGN DETAILS AND
12 NEW ASSET INSPECTION SHEET See separate document: S5b – New Asset Inspection Sheet
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 61 TECHNICAL NOTES FOR OPEN SPACE
13 LIST OF INDIGENOUS PLANT SUPPLIERS 1. Western Plains Flora
Telephone 9740-3178 628 Wildwood Road Wildwood
2. Greybox and Grassland Indigenous Nursery
Telephone 5369-5221 50 Schools Road Balliang East 3340
3. Victorian Indigenous nurseries Co-operative
Telephone 9482-1710 Yarra Bend Road PO Box 24 Fairfield 3978
PAGE 62 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
14 LANDSCAPE TREATMENTS TABLE 14.1 Appropriate landscape treatments for neighbourhood landscape character types
Neighbourhood Landscape Character
Formal Annual Garden
Bed
Formal Perennial Planting
Formal Groundcover
Shrub Massing or
Hedging
Informal Shrub
Massing (indigenous,
native or exotic)
Low Informal Groundcover
and Shrub Planting
Indigenous Groundcover
Indigenous Mixed
Groundcover and Shrub Massing
Indigenous Shrub & Tree
(including Greening
Revegetation Beds)
Indigenous Tree &
Groundcover massing
Indigenous Tree
Massing
Indigenous Trees
(discrete)
Advanced Canopy
Trees (non indigenous)
Irrigated mown turf
(lawn)
Non-irrigated
mown turf
Differentiallymown turf
Rough Turf or
Grassed Area
MownTurf Path
Bushland Reserve no no no yes(1) no yes yes yes yes yes yes no no yes yes yes yes Creek/Drainage Corridor
no no no yes no yes yes yes yes yes yes no no yes yes yes yes
Formal/Ornamental Garden
no yes yes no no no no no no no yes yes yes yes no no no
Lake no no yes yes yes yes yes yes yes yes yes yes yes(3) yes no yes yes Narrow Grassed or Paved Walking / Access way
no no no no no yes no no yes(5) yes yes yes(5) no yes no no no
Open Parkland no no no yes yes(3) yes(3) yes yes(1) yes(3) yes yes yes yes(3) yes no no no Outdoor sports facility
no no no yes(1) yes yes(4) yes(1) yes(1) yes yes yes yes Playing field only
surrounds no yes no
Roadside Plantation/Tree Reserve
no no no yes(2) yes no yes(2) yes(2) yes yes yes no no yes no no no
Wetland/Retarding Basin
no no no yes(1) yes yes yes(1) yes(1) yes yes yes no no yes no yes no
Facility surrounds no yes yes yes(1) yes yes yes(1) yes(1) yes no yes yes yes yes no no no 1. For screening - to maintain vision 2. To maintain motorist vision 3. At activity nodes 4. In association buildings and carparks 5. Entrances only
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 63 TECHNICAL NOTES FOR OPEN SPACE
14.2 Appropriate candscape treatments for subregional landscape character types Sub Regional Landscape Character
Formal Annual Garden
Bed
Formal Perennial Planting
Formal Groundcover
Shrub Massing or
Hedging
Informal Shrub
Massing (indigenous,
native or exotic)
Low Informal Groundcover
and Shrub Planting
Indigenous Groundcover
Indigenous Mixed
Groundcover and Shrub Massing
Indigenous Shrub & Tree
(including Greening
Revegetation Beds)
Indigenous Tree &
Groundcover massing
Indigenous Tree
Massing
Indigenous Trees
(discrete)
Advanced Canopy
Trees (non indigenous)
Irrigated mown turf
(lawn)
Non-irrigated
mown turf
Differentiallymown turf
Rough Turf or
Grassed Area
MownTurf Path
Bushland no no no yes(1) no yes yes yes yes yes yes no no yes yes yes yes Creek/Drainage Corridor
no no no yes(1) no yes yes yes yes yes yes no no yes yes yes yes
Formal/Ornamental Garden
yes yes yes yes no no no no yes yes yes yes yes yes no no yes
Lake yes(4) yes yes yes yes yes yes yes yes yes yes yes yes(3) yes yes yes yes Narrow Grassed or Paved Walking / Access way
no no no yes(1) yes yes no no yes yes yes yes no yes no no no
Open Parkland no no yes yes yes yes yes yes yes yes yes yes yes(3,5) yes yes yes yes Outdoor Sports Facility
no no yes yes(1) yes yes yes(1) yes(1) yes yes yes yes Playing fields only
surrounds no no no
Roadside Plantation/Tree Reserve
no no no yes(2) yes yes yes(2) yes(2) yes yes yes yes no yes yes no no
Wetland/Retarding Basin
no no no yes(1) no yes yes yes yes yes yes no no yes yes yes yes
Facility surrounds yes(4) yes yes yes(1) yes yes yes(1) yes(1) yes yes yes yes yes yes no no no 1. For screening - to maintain vision 2. To maintain motorist vision 3. At activity nodes 4. In association with civic space 5. Entrances only
PAGE 64 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
14.3 Appropriate landscape treatments for regional landscape character types
Regional LandscapeCharacter
Formal Annual Garden
Bed
Formal Perennial Planting
Formal Groundcover
Shrub Massing or
Hedging
Informal Shrub
Massing (indigenous,
native or exotic)
Low Informal Groundcover
and Shrub Planting
Indigenous Groundcover
Indigenous Mixed
Groundcover and Shrub Massing
Indigenous Shrub & Tree
(including Greening
Revegetation Beds)
Indigenous Tree &
Groundcover massing
Indigenous Tree
Massing
Indigenous Trees
(discrete)
Advanced Canopy
Trees (non indigenous)
Irrigated mown turf
(lawn)
Non-irrigated
mown turf
Differentiallymown turf
Rough Turf or
Grassed Area
MownTurf Path
Bushland no no no yes no yes yes yes yes yes yes no no yes yes yes yes Creek/Drainage Corridor
no no no yes no yes yes yes yes yes yes no no yes yes yes yes
Formal/Ornamental Garden
yes yes yes yes yes yes no no yes yes yes yes yes no no no yes
Lakes yes (4) yes yes yes yes yes yes yes yes yes yes yes yes(3) yes yes yes yes Narrow Grassed or Paved Walking / Access way
no no no yes(4) yes yes no no yes yes yes yes yes(5) yes no no no
Open Parkland no yes yes yes yes yes yes yes yes yes yes yes yes(3,5) yes yes yes yes Outdoor Sports Facility
no yes yes yes(4) yes yes yes(4) yes(4) yes yes yes yes yes- playing fields (3,5)
surrounds no no no
Roadside Plantation/Tree Reserve
no no no yes(2) yes yes yes(2) yes(2) yes yes yes yes no yes yes no no
Wetland/Retarding Basin
no no no yes no yes yes yes yes yes yes no no yes yes yes yes
Facility surrounds yes(4) yes yes yes(4) yes yes yes(4) yes(4) yes yes yes yes yes yes no no no 1. For screening - to maintain vision 2. To maintain motorist vision 3. At activity nodes 4. In association with civic space 5. Entrances only
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 65 TECHNICAL NOTES FOR OPEN SPACE
14.4 Appropriate landscape treatments for roadside landscapes
Formal Annual Garden
Bed
Formal Perennial Planting
Formal Groundcover
Shrub Massing or
Hedging
Informal Shrub
Massing (indigenous,
native or exotic)
Low Informal Groundcover
and Shrub Planting
Indigenous Groundcover
Indigenous Mixed
Groundcover and Shrub Massing
Indigenous Shrub & Tree
(including Greening
Revegetation Beds)
Indigenous Tree &
Groundcover massing
Indigenous Tree
Massing
Indigenous Trees
(discrete)
Advanced Canopy
Trees (non indigenous)
Irrigated mown turf
(lawn)
Non-irrigated
mown turf
Differentially mown turf
Rough Turf or
Grassed Area
MownTurf Path
Urban Road Reserves
arterial yes(2) yes(2) yes yes(1) yes yes yes(1) yes(1) yes yes yes yes no yes no no no collector no no no no yes yes no no yes yes(1) yes yes no yes no no no access no no no no no no no no no no yes yes no yes no no yes
Urban Roundaboutsand Traffic Treatments
arterial no no no no yes yes no no yes yes(1) yes yes no yes no no no collector no no no no yes yes no no yes yes(1) yes yes no yes no no no access no no no no no no no no yes no no yes no yes no no no
Rural Roundabouts arterial no no no no yes yes no no yes yes(1) yes yes no yes no no no
collector no no no no yes yes no no yes yes(1) yes Yes no no no no no 1. To maintain motorist vision 2. In association with civic space
PAGE 66 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
15 LIST OF REFERRAL DOCUMENTS Children Services Regulations 1998 Hume Bicycle Strategy Plan 1996 Hume City Council Street and Reserve Tree Policy 1996 Hume Greening Strategy 1996 Hume Interpretation Strategy 1999 Hume Open Space Strategy 1999
HUME CITY DESIGN DETAILS AND OCTOBER 2003 PAGE 67 TECHNICAL NOTES FOR OPEN SPACE
16 POLICY FOR THE PROTECTION OF VEGETATION IN IDENTIFIED VEGETATION PROTECTION AREAS (VPAS)
16.1 Policy Basis
The protection of remnant and other significant vegetation in the assessment of planning applications is identified specifically within the Hume Planning Scheme and is included in the assessment of Planning Permit Applications. Where vegetation (which may include trees, shrubs and/or ground flora) is identified and recommended for protection in a planning permit, appropriate management during development works is critical to its retention and long-term survival. Damage to branches, compaction of soil, covering of ground flora and so forth must be avoided. The identification of Vegetation Protection Areas (VPAs), which will incorporate all of the significant vegetation identified during the planning process, and compliance with the following requirements will ensure that significant vegetation is given full protection in the spirit of the Planning Scheme.
16.2 Objective
To ensure the protection, during development works, of significant vegetation that has been identified for protection in the planning process.
16.3 Policy
It is Council’s policy that any remnant or other significant vegetation identified for protection in a planning permit will be included in a Vegetation Protection Area (VPA) to be clearly identified in the Planning Permit.
The following requirements are to be followed during the course of all development works in order to comply with the planning permit conditions:
1. Prior to the commencement of works, the boundaries of defined VPAs are to be fully fenced, and fencing maintained during development works, to the satisfaction of Council, unless otherwise indicated in the Planning Permit conditions. Fences are to, as a minimum standard, comprise of star pickets, at an interval of 1.5m, two strands of wire, top and bottom, and parawebbing securely fixed to the wire. In some instances, temporary cyclone fencing may be required.
2. The Developer and any Contractors shall refrain from destroying, removing, pruning or clearing any vegetation growing within Vegetation Protection Areas or removal of any rocks and soil. Where it is necessary to remove or prune existing vegetation, beyond that identified specifically in the planning permit, written approval must first be obtained from Council and an amendment to the planning permit may be required.
3. Any approved tree pruning must be undertaken by a qualified arborist.
4. The storage or mixing of materials and chemicals; vehicle passage or parking; disposal of liquids, soil or building refuse; machinery repairs and refuelling or construction of site buildings shall not occur within a nominated VPA.
5. No signs, stays, guys or other objects are to be attached to trees or placed within any nominated VPA.
PAGE 68 OCTOBER 2003 HUME CITY DESIGN DETAILS AND TECHNICAL NOTES FOR OPEN SPACE
6. No stormwater or sediment is to be diverted temporarily from or to a VPA (ie. no changes, additional to changes to drainage or landform, as approved within the planning permit).
7. Council is to be informed within 48 hours of any damage to tree trunks, crown or root systems. All damage is to be immediately repaired by a qualified arborist to the satisfaction of Council. Cut branches and roots are not to be sealed with wound sealing products unless specified by Council.
8. Council is to be informed by the applicant, or their nominee, of any damage to the VPA, within 48 hours. All damage is, where possible, to be repaired to Council’s satisfaction.
9. No soil disturbance, including cut and fill operations, is to occur within VPAs. Where disturbance is specifically permitted in the Planning Permit, the original surface profile is be restored and replanted with species identified by Council, unless otherwise specified in the Planning Permit.
10. Where excavations are carried out to within 5 metres of a VPA, a hand excavated trench is to be used to locate roots. In some circumstances a lesser distance may be negotiated prior to the issue of a Planning Permit, depending on vegetation type, works proposals etc. Any tree roots greater than 40mm in diameter must be clean cut with a sharp saw and notification must be provided immediately by the applicant or their nominee to Council, who may arrange inspection of the works.
11. Control of herbaceous or woody weeds within a VPA is only to be undertaken using approved herbicides and hand tools. Weed control requiring other equipment is to be undertaken only with permission from Council.
16.4 Non-compliance directive
Should the vegetation within any VPA’s be damaged or removed in error by the Developer or their Contractors, damage shall be assessed and restoration works are to be conducted by the Developer to Council’s satisfaction. Additionally, penalties associated with a breach of planning permit conditions may be applicable.
16.5 Review