  • S-PRO 4000Model: S-PRO 4001

    Sub-HarmonicMonitoring and Protection Relay

    User ManualVersion 2.0 Rev 1

    G

  • D03957R02.01 S-PRO 4000 User Manual, Model: S-PRO 4001 i

    Preface

    Information in this document is subject to change without notice. 2015 ERLPhase Power Technologies Ltd. All rights reserved.Reproduction in any manner whatsoever without the written permission of ERLPhase Power Technologies Ltd. is strictly forbidden.This manual is part of a complete set of product documentation that includes detailed drawings and operation. Users should evaluate the information in the context of the complete set of product documentation and their particular applications. ERLPhase assumes no liability for any incidental, indirect or consequential damages arising from the use of this documentation.While all information presented is believed to be reliable and in accordance with accepted engineering practices, ERLPhase makes no warranties as to the completeness of the information.All trademarks used in association with B-PRO, B-PRO Multi Busbar, Multi Busbar Protection, F-PRO, iTMU, L-PRO, ProLogic, S-PRO, T-PRO, TESLA, I/O Expansion Module, TESLA Control Panel, Relay Control Panel, RecordGraph and RecordBase are trademarks of ERLPhase Power Technologies Ltd.Windows is a registered trademark of the Microsoft Corporation.HyperTerminal is a registered trademark of Hilgraeve.Modbus is a registered trademark of Modicon.

    Contact Information

    ERLPhase Power Technologies Ltd.74 Scurfield Blvd.Winnipeg, Manitoba, CanadaR3Y 1G4Website: www.erlphase.comEmail: [email protected]

    Technical SupportEmail: [email protected]: 1-204-477-0591

  • D03957R02.01 S-PRO 4000 User Manual, Model: S-PRO 4001 iii

    Using This Guide

    This User Manual describes the installation and operation of the S-PRO pro-tection relay. It is intended to support the first time user and clarify the details of the equipment.

    The manual uses a number of conventions to denote special information:

    Example Describes

    Start>Settings>Control Panel Choose the Control Panel submenu in the Set-tings submenu on the Start menu.

    Right-click Click the right mouse button.

    Recordings Menu items and tabs are shown in italics.

    Service User input or keystrokes are shown in bold.

    Text boxes similar to this one Relate important notes and information.

    .. Indicates more screens.

    Indicates further drop-down menu, click to dis-play list.

    Indicates a warning.

  • D03957R02.01 S-PRO 4000 User Manual, Model: S-PRO 4001 v

    Acronyms

    ASG - Active Setting Group

    CID - file extension (.CID) for Configured IED Description

    CS - Control Switch

    CT - Current Transformer

    DCB - Directional Comparison Blocking

    DCE - Data Communication

    DIB - Digital Input Board

    DIGIO - Digital Input/Output Board

    DSP - Digital signal processor

    DTE - Data Terminal Equipment

    FPCB - Graphics Front Panel Comm Board

    FPDB - Graphics Front Panel Display Board

    GPS - Global Positioning System

    HMI - Human Machine Interface

    ICD - file extension (.ICD) for IED Capability Description

    IEC - International Electrotechnical Commission

    IED - Intelligent Electronic Device

    IP - Internet Protocol (IP) address

    IRIG-B - Inter-range instrumentation group time codes

    LED - Light-emitting Diode

    LHS - Left Hand Side

    LOP - Loss of Potential

    MPB - Main Processor Board

    MPC - Micro Processor

  • Acronyms

    vi S-PRO 4000 User Manual, Model: S-PRO 4001 D03957R02.01

    RAIB -Relay AC Analog Input Board

    RASB -Relay AC Analog Sensor Boards

    RHS - Right Hand Side

    RPCB - Rear Panel Comm Board

    RTOS - Real Time Operating System

    RTU - Remote Terminal Unit

    SCADA - Supervisory Control And Data Acquisition

    SG - Setting Group

    TUI - Terminal User Interface

    UI - User Interface

    VI - Virtual Input

  • D03957R02.01 S-PRO 4000 User Manual, Model: S-PRO 4001 vii

    Table of Contents

    Preface ......................................................................................iContact Information ...................................................................iUsing This Guide ..................................................................... iiiAcronyms..................................................................................vTable of Contents ................................................................... viiVersion Compatibility ...............................................................xiPC System Requirements and Software Installation ............. xiii

    1 Overview ................................................................. 1-1Introduction ...................................................................... 1-1Front View........................................................................ 1-2Rear View ........................................................................ 1-2Model Options/Ordering................................................... 1-3

    2 Setup and Communications.................................. 2-1Introduction ...................................................................... 2-1IRIG-B Time Input ............................................................ 2-1Communicating with the Relay ........................................ 2-2USB Link .......................................................................... 2-2Network Link .................................................................... 2-5Direct Serial Link.............................................................. 2-6Modem Link ..................................................................... 2-7Using HyperTerminal to Access the Relays Maintenance Menu ................................................................................ 2-9Firmware Update ........................................................... 2-12Setting the Baud Rate.................................................... 2-13Accessing the Relays SCADA Services........................ 2-14Communication Port Details .......................................... 2-15

    3 Using the IED (Getting Started) ............................ 3-1Introduction ...................................................................... 3-1Start-up Sequence ........................................................... 3-1Interfacing with the Relay................................................. 3-1Front Panel Display.......................................................... 3-2Terminal Mode ................................................................. 3-7Relay Control Panel ......................................................... 3-7

    4 Protection and Recording Functions ................... 4-1

  • Table of Contents

    viii S-PRO 4000 User Manual, Model: S-PRO 4001 D03957R02.01

    S-PRO Features .............................................................. 4-1S-PRO Protection Functions............................................ 4-2Description Of The S-PRO Logic ..................................... 4-3Recording Functions ........................................................ 4-5Event Log......................................................................... 4-7Fault Log .......................................................................... 4-8

    5 Data Communications ........................................... 5-1Introduction ...................................................................... 5-1SCADA Protocol .............................................................. 5-1IEC 61850 Communication .............................................. 5-7

    6 Offliner Settings Software ..................................... 6-1Introduction ...................................................................... 6-1Offliner Features .............................................................. 6-2Offliner Keyboard Shortcuts............................................. 6-4Main Branches from the Tree View.................................. 6-5Settings From a Record ................................................. 6-21

    7 Acceptance/Protection Function Test Guide ...... 7-1Introduction ...................................................................... 7-1Acceptance Testing ......................................................... 7-1

    8 Installation and Safety Instructions ..................... 8-1Introduction ...................................................................... 8-1 Physical Mounting.......................................................... 8-2Case Grounding............................................................... 8-3Power Supply................................................................... 8-4AC and DC Wiring............................................................ 8-5Communication Wiring..................................................... 8-6

    Appendix A IED Specifications..................................... A-1External Input Pickup Filter ..............................................A-7

    Appendix B IED Settings and Ranges ......................... B-1Settings and Ranges........................................................B-1

    Appendix C Hardware Description ...............................C-1Appendix D Event Messages.......................................D-1Appendix E Modbus RTU Communication Protocol .... E-1Appendix F DNP3 Device Profile ................................. F-1Appendix G Mechanical Drawings ...............................G-1Appendix H Rear Panel Drawings................................H-1

  • Table of Contents

    D03957R02.01 S-PRO 4000 User Manual, Model: S-PRO 4001 ix

    Appendix I AC Schematic Drawings ............................. I-1Appe