rx-path-balance-check-v1-00.docx

Upload: amit-kumar-raut

Post on 04-Jun-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/14/2019 RX-Path-Balance-Check-V1-00.docx

    1/10

    TRX Path-Balance Check Confidentiality:

    2013-11-11 Huawei Confidential Page 1 of 10

    Document

    Name

    TRX Path-Balance Check SOP Guideline V1.00

    Version V1.00 Effective Date 2010-07-31

    Document

    CodeL1

    Based eTOMs

    Prepared By L2Based eTOMs

    Reviewed By L3Based eTOMs

    Approved By L4Based eTOMs

    Applicability GlobalStandard

    Roles

    Analysis engineer Blank

    Relevant Process/Regulation

    Document Name Document Code

  • 8/14/2019 RX-Path-Balance-Check-V1-00.docx

    2/10

    TRX Path-Balance Check Confidentiality:

    2013-11-11 Huawei Confidential Page 2 of 10

    Contents

    Relevant Process/Regulation............................................................... 1

    1 Abstract ............................................................................. 3

    2 Purpose .............................................................................. 3

    Operating Instructions ................................................................... 4

    2.1 Link Balance Equations: .......................................................... 4

    2.2 Counters used for path-balance Judgment .......................................... 4

    2.3 Judgment Criteria ................................................................ 6

    2.4 Normal Trend for Path-Balance .................................................... 6

    2.5 Weak DL Trend for Path-Balance ................................................... 7

    2.6 Weak UL Trend for Path-Balance ................................................... 8

    2.7 Misleading Case for Path-Balance ................................................. 9

    3 Appendix ............................................................................ 10

    4 Support Document(s) ................................................................. 10

    5 Related Document(s) ................................................................. 10

    6 Record Retention .................................................................... 10

    7 Document Preparation/Modification Record ............................................ 10

  • 8/14/2019 RX-Path-Balance-Check-V1-00.docx

    3/10

    TRX Path-Balance Check Confidentiality:

    2013-11-11 Huawei Confidential Page 3 of 10

    1 Abstract

    This document instructs engineers how to perform the Base Band Hopping audit.

    2 Purpose

    This document aims to standardize the operation procedure of Path-Balance Judgment

    1. Link balance Equations

    2. Counters used for path-balance Judgment

    3. Judgment Criteria

    4. Normal Balance Trend

    5. Weak UL Trend

    6. Weak DL Trend

    7. Misleading Case

  • 8/14/2019 RX-Path-Balance-Check-V1-00.docx

    4/10

    TRX Path-Balance Check Confidentiality:

    2013-11-11 Huawei Confidential Page 4 of 10

    Operating Instructions

    2.1 Link Balance Equations:

    UL/DL Path balance difference = UL path loss - DL path loss = (MS real transmit

    power-UL Rx_Lev) - (BTS cabinet output power-DL Rx_Lev).

    BTS cabinet output power=TRX power-static power class*2 + Power fine tuning -

    Combiner loss- DL dynamic PC level*2 + dynamic PBT gain2.2 Counters used for path-balance Judgment

    The below counters define the balance status of the TRX into 11 levels and the balance should be around

    level 6 The levels below level 6 indicates the status of the UL

    The levels above level 6 indicates the status of the DL

    Level 1 Indicates that the UL > DL by 15

    Level 1 Indicates that the DL > UL by 15

  • 8/14/2019 RX-Path-Balance-Check-V1-00.docx

    5/10

    TRX Path-Balance Check Confidentiality:

    2013-11-11 Huawei Confidential Page 5 of 10

    BSC 6900 TRX Level Balance CountersUL/DL Path-balance

    Diffrence Comment

    S462A:Number of MRs (Uplink-and-Downlink Balance Level = 1)(none) X DL

    S462B:Number of MRs (Uplink-and-Downlink Balance Level = 2)(none) -14 < x < -11 UL > DLS462C:Number of MRs (Uplink-and-Downlink Balance Level = 3)(none) -10 < x < -8 UL > DL

    S462D:Number of MRs (Uplink-and-Downlink Balance Level = 4)(none) -7 < x < -5 UL > DL

    S462E:Number of MRs (Uplink-and-Downlink Balance Level = 5)(none) -4 < x < -2 UL > DL

    S462F:Number of MRs (Uplink-and-Downlink Balance Level = 6)(none) -1 < x < 1 Balance

    S462G:Number of MRs (Uplink-and-Downlink Balance Level =

    7)(none) 2 < x < 4 DL > UL

    S462H:Number of MRs (Uplink-and-Downlink Balance Level = 8)(none) 5 < x < 7 DL > UL

    S462I:Number of MRs (Uplink-and-Downlink Balance Level = 9)(none) 8 < x < 10 DL > UL

    S462J:Number of MRs (Uplink-and-Downlink Balance Level =

    10)(none) 11 < x < 14 DL > UL

    S462K:Number of MRs (Uplink-and-Downlink Balance Level =

    11)(none) X => 15 DL > UL

  • 8/14/2019 RX-Path-Balance-Check-V1-00.docx

    6/10

    TRX Path-Balance Check Confidentiality:

    2013-11-11 Huawei Confidential Page 6 of 10

    2.3 Judgment Criteria

    The criteria used to judge if the TRX is Balance or not is as following:

    1- `Shape of the graph should be centered on Level 6

    2- Sum of Levels (1 + 2) should be Less Than 20 % from the total value of Levels 1 to 11 (around the

    20 %)

    3- Sum of Levels (10 + 11) should be Less Than 25 % from the total value of Levels 1 to 11 (around the

    25 %)

    2.4 Normal Trend for Path-Balance

    The Normal Trend of the balance means that the measurement should be around level 6 as shown below

  • 8/14/2019 RX-Path-Balance-Check-V1-00.docx

    7/10

    TRX Path-Balance Check Confidentiality:

    2013-11-11 Huawei Confidential Page 7 of 10

    2.5 Weak DL Trend for Path-Balance

    Weak DL means that the measurement of the UL Level counters is higher than the DL counters (Levels 1+2

    is Higher than 20 % from the total Measurement)

  • 8/14/2019 RX-Path-Balance-Check-V1-00.docx

    8/10

    TRX Path-Balance Check Confidentiality:

    2013-11-11 Huawei Confidential Page 8 of 10

    2.6 Weak UL Trend for Path-Balance

    Weak DL means that the measurement of the DL Level counters is higher than the UL counters (Levels

    10+11 is Higher than 25 % from the total Measurement)

  • 8/14/2019 RX-Path-Balance-Check-V1-00.docx

    9/10

    TRX Path-Balance Check Confidentiality:

    2013-11-11 Huawei Confidential Page 9 of 10

    2.7 Misleading Case for Path-Balance

    In the below case the measurement of Levels 10+11 is 22% which is good and accepted but from the TRX

    chart we can see that the TRX suffers from Weak-UL status as shown below

    So the conclusion from this case is that:

    1- Percentage is just an indication to determine the worst cases

    2- The judgment must be done for case by case specially for the TRXs with percentage around 20% for

    both UL/DL indicators (Levels 1+2 or Level 10+11)

  • 8/14/2019 RX-Path-Balance-Check-V1-00.docx

    10/10

    TRX Path-Balance Check Confidentiality:

    2013-11-11 Huawei Confidential Page 10 of 10

    3 Appendix

    Not Required

    4 Support Document(s)

    No. Document name Document code

    1.

    5 Related Document(s)

    Front-end and Back-end Document name Document Code

    6 Record Retention

    Record

    Name

    Hand over

    Owner

    Retention

    Owner

    Retention

    Location

    Filing Date Retention

    Period

    Disposition at

    Expiry

    Problem

    escalation

    (GCRMS)

    7 Document Preparation/Modification Record

    (Manda tory)

    Version

    Prepared/Modified

    By

    Preparation/Modification

    Date

    Content/Reason for Modification

    Approved

    By

    V1.00 Mostafa Ibrahim

    701891

    (Egypt 3rd

    licence)

    2010.8.31 New Version Zhu

    yongsheng

    108866