rwac-1 residential wiring and control

2
Residential Wiring and Controls (RWAC-1)* is a stand-alone benchtop training station providing students with funda- mental knowledge of Residential Wiring, essential for success in career-based training. Residential Wiring and Controls (RWAC-1) presents the work- ing principles of electrical wiring the most effective way: using the same industrial-strength components used in industry. Students learn the principles of residential power electricity from the utility pole to all major residential pur- poses, inlcuding smoke alarms, lighting and circuit breakers. The included Student Study Guide lays a solid foundation in the theory and concepts involved in residential wiring as well as guiding students step by step through hands-on lab activities with the trainer equipment. www.intelitek.com Residential Wiring & Controls (RWAC-1) I NDUSTRIAL M AINTENANCE P r o g r a m I n d u s t r i a l M a i n t e n a n c e The Greystone line of training systems offers an all-in-one solution for your mechatronics and industrial maintenance lab! Durable lab equipment and rigorous courseware combine to deliver all you need for your secondary or post- secondary career and technology education program. These robust, versatile training stations allow for in-depth training in small spaces. From desktop trainers to mobile training stations, Greystone stations feature industrial-grade components incorporated into rugged aluminum frame- work. All trainers include competency-based curriculum with emphasis on operating theory, installation, mainte- nance, and troubleshooting. Give your trainees and students the advantage of working with the same equipment they will encounter in industry. Choose Greystone training systems! *Available to North American markets only. EXPAND Y OUR INDUSTRIAL T RAINING PROGRAM Increase the versatility of your training program with the following additional options and related hardware: Electrical Control Training: Industrial Power Control, Motor Control, PLCs Electrical Wiring HVAC Control Training Mechanical Training: Machine Shaft Alignment, Vibration Analysis

Upload: intelitek-inc

Post on 28-Mar-2016

224 views

Category:

Documents


0 download

DESCRIPTION

RWAC-1 Residential Wiring and Control

TRANSCRIPT

Page 1: RWAC-1 Residential Wiring and Control

Residential Wiring and Controls (RWAC-1)* is a stand-alone benchtop training station providing students with funda-mental knowledge of Residential Wiring, essential for success in career-based training.

Residential Wiring and Controls (RWAC-1) presents the work-ing principles of electrical wiring the most effective way: using the same industrial-strength components used in industry. Students learn the principles of residential power electricity from the utility pole to all major residential pur-poses, inlcuding smoke alarms, lighting and circuit breakers.

The included Student Study Guide lays a solid foundation in the theory and concepts involved in residential wiring as well as guiding students step by step through hands-on lab activities with the trainer equipment.

www.intelitek.com

Residential Wiring & Controls(RWAC-1 )

I n d u s t r I a l M a I n t e n a n c e

Program

Indust

rial Mainten

ance

The Greystone line of training systems offers an all-in-one solution for your mechatronics and industrial maintenance lab! Durable lab equipment and rigorous courseware combine to deliver all you need for your secondary or post-secondary career and technology education program.

These robust, versatile training stations allow for in-depth training in small spaces. From desktop trainers to mobile training stations, Greystone stations feature industrial-grade components incorporated into rugged aluminum frame-work. All trainers include competency-based curriculum with emphasis on operating theory, installation, mainte-nance, and troubleshooting.

Give your trainees and students the advantage of working with the same equipment they will encounter in industry. Choose Greystone training systems!

*Available to North American markets only.

�Expand Your IndustrIal traInIng program

Increase the versatility of your training program with the following additional options and related hardware:

� Electrical Control Training: Industrial Power Control, Motor Control, PLCs

� Electrical Wiring

� HVAC Control Training

� Mechanical Training: Machine Shaft Alignment, Vibration Analysis

Page 2: RWAC-1 Residential Wiring and Control

Materials IncludedOrder # 10-RWAC-0000

� Frame Size: 30"h x 48"w x 20"d

� Overall Size: 37"h x 56"w x 20"d

� Weight (approximate): 80 lbs

� Construction: Anodized aluminum U-shaped frame with environmentally stabilized, non-conductive polymer back and side panels. All electrical components are permanently mounted to the back and side panels

� Electrical connections: � Electrical components are wired through industry-standard terminal strips rated at 50-amps @ 600-volts

� Terminal strips feature recessed and insulated fasteners and are field-serviceable

� Electrical connections are completed through color-coded 16-gauge insulated and stranded lead wires

� Each connecting lead wire is terminated on each end with metal uninsulated, crimped ferrules

� Power Requirements: 220V AC 15A single-phase

� Student study guide

� Installation guide

Optional Curriculum Supplements � Residential Wiring - Textbook Order # 10-RWAC-TB01

� Residential Wiring - Instructors guide Order # 10-RWAC-IG01

� National Electrical Code - Soft Cover Order # 10-RWAC-NEC1

�� Activity�1:�General�Information�and�Safety�� Activity�2:�Electrical�Symbols�and�Wall�Boxes�� Activity�3:�Service�Entrance�Equipment�� Activity�4:�Circuit�Breakers�� Activity�5:�Wiring�a�Sub-Panel�� Activity�6:�Receptacles�� Activity�7:�Conductors�� Activity�8:�Luminaires,�Ballasts,�and�Lamps

�� Activity�9:�Single-Pole,�Timer�and�Dimmer�Switches

�� Activity�10:�Three-way�Switching�� Activity�11:�Four-way�Switching�� Activity�12:�Split�Circuit�Receptacles�� Activity�13:�Special-Purpose�Receptacles��� Activity�14:�Ground-Fault�Circuit�Interrupters�� Activity�15:�Arc-Fault�Circuit�Interrupters�� Activity�16:�Television�and�Telephone�Systems

�� Activity�17:�Signal�Systems�(Door�Chimes)�� Activity�18:�AC/DC�Smoke�Detectors�� Activity�19:�Wiring�the�Bedroom�� Activity�20:�Wiring�the�Master�Bedroom�� Activity�21:�Wiring�the�Bathroom�� Activity�22:�Wiring�the�Porch�� Activity�23:�Wiring�the�Kitchen�� Activity�24:�Wiring�the�Living�Room�� Activity�25:�Wiring�the�Study

�� Activity�26:�Wiring�the�Laundry�Room�� Activity�27:�Wiring�the�Garage�� Activity�28:�Wiring�the�Recreation�Room�� Activity�29:�Wiring�the�Workshop��� Activity�30:�Special-Purpose�Outlets�� Activity�31:�Central�Heating�Systems�� Activity�32:�Water�Hazards�� Activity�33:�Home�Automation�Systems�� Activity�34:�Standby�Power�Systems

Residential Wiring & Controls

All specifications subject to change without notice. All trademarks are property of their respective owners. 35-RWAC-DS01 Rev-B

Affiliated with:

� A stand-alone, portable training station providing 50 hours of combined classroom and laboratory training in the following topics:

� Draw and read electrical plans � Service entrance wiring � Sub-panel wiring � 1-way, 2-way, 3-way and 4-way switching � Dimmers � Duplex, appliance and GFCI receptacles

� GFI and AFI circuit breakers � Incandescent, fluorescent and security lighting

� Door chime wiring � Smoke alarm wiring � Timers � Data, video and communications wiring

Indust

rial Mainten

ance

M

echatronics

Advance

d Manufacturin

g

Make Greystone Training Systems part of a comprehensive STEM program! Add virtual, hardware-based or blended learning labs to deliver in-depth Industrial Maintenance, Mechatronics and Advanced Manufacturing and Agricultural programs.

Program

Indust

rial Mainten

ance

Course Outline

Trainer shown with textbooks, sold separately.