rst12-2 piezometer data p1 & p2

Upload: mauricio-santisteban-campos-robles

Post on 09-Mar-2016

212 views

Category:

Documents


0 download

DESCRIPTION

geo

TRANSCRIPT

  • RST12 - 2; Test Piezometer Hole P1 - Standpipe

    Piezometer Zone: 14.00 to 18.29 EOHCollar Elevation:

    Date Time Hole DepthTo W.L. (m)

    24-May-12 9:00 3.6613-Jun-12 15:00 3.7424-Aug-12 15:15 3.71

    6-Sep-12 16:00 3.9712-Sep-12 10:00 4.01 - Pre Falling Head Test

    Notes:

  • 02/06/2016 303435175.xlsx

    RST12 - 2; Test Piezometer Hole P2 - Grouted-In VW Piezometer

    Transducer Model - VW2100-0.35Manufacture No. - 1146260S/N - VW21753Range - 0.350 mPaDepth in Hole = 10.18 mCollar Elevation = ------------

    Date Time B Pos Temp Baro(degree C) (mBars)

    14-May-12 n/a 9056.5 22.3 999.8 - Calibration - Prior to 14 May 201214-May-12 n/a 9046.0 20.7 1019.5 - Shipped Zero Reading22-May-12 n/a 9050.0 14.3 1012.0 - Installation Zero Reading

    Calibration Factor (CF): = 0.098202 kPa/BTemp Correction (Tk): = -0.04411 kPa/degree C rise

    Date Time B Pos Temp Baro P (kPa) P (mPa) Meters Hole Depth %(degree C) (mBars) (Notes 1&2) Head To W.L. (m) Accuracy

    14-May-12 n/a 9056.5 22.3 999.8 0.000000 0 0.00 n/a n/a - Calibration14-May-12 n/a 9046.0 20.7 1019.5 -0.868303 -0.000868 -0.09 n/a -0.25 - Shipped Zero Reading22-May-12 12:00 9050.0 14.3 1012.0 -0.228807 -0.000229 -0.02 n/a -0.07 - Installation Zero Reading

    23-May-12 12:00 8385.5 13.5 1014.3 64.831710 0.064832 6.61 3.57 24-May-12 9:00 8387.8 12.9 1013.1 64.752311 0.064752 6.60 3.5813-Jun-12 15:00 8375.2 11.9 1021.5 65.193767 0.065194 6.65 3.53

    24-Aug-12 15:15 8397.4 11.8 1021.0 63.068093 0.063068 6.43 3.756-Sep-12 17:00 8405.5 11.7 1017.0 62.677068 0.062677 6.39 3.79

    12-Sep-12 10:00 8397.4 11.7 1029.0 62.272504 0.062273 6.35 3.83

    Notes:1) Barometric correction is applied, but may not be applicable, if downhole zone is isolated.2) P(kPa) = [C.F.(Li-Lc)] - [Tk(Ti-Tc)] + [0.1(Bi-Bc)]

    Where: L is B Unit readingT is Temperature readingB is Barometric Pressure reading i is the Initial Reading from the instrument calibration c is the Current Reading

    3) Conversion mPa to meters water head = mPa x 101.99773

    P1 - SPP2 - VW