SPLIT AIR CONDITIONER SYSTEM 13 SEER SPECIFICATIONS Refrigerant System • R410a Refrigerant High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity Top discharge directs hot air away from living area and shrubbery All units factory run tested Easy access to electrical panels Corner mounted service valves for easy hook-up and service Liquid line filter drier shipped loose Charged for 15 feet of interconnecting tubing All units ETL and ETLC approved and AHRI certified Warranty Standard warranty or Extended warranty available with product registration. See warranty document for details or visit www.marsdelivers.com RSG13**S1M

Upload: others

Post on 21-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RSG13**S1M...(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095 (C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178 (C,M,V)CG18PA1M 13 11 17,100 202083720 (C,M,V)CG18PB1M 13 11 17,100

SPLIT AIR CONDITIONER SYSTEM

13 SEERSPECIFICATIONSRefrigerant System• R410a Refrigerant

• High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity

• Top discharge directs hot air away from living area and shrubbery

• All units factory run tested

• Easy access to electrical panels

• Corner mounted service valves for easy hook-up and service

• Liquid line filter drier shipped loose

• Charged for 15 feet of interconnecting tubing

• All units ETL and ETLC approved and AHRI certified

Warranty Standard warranty or Extended warranty available with product registration.

See warranty document for details or visit www.marsdelivers.com

RSG13**S1M

Page 2: RSG13**S1M...(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095 (C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178 (C,M,V)CG18PA1M 13 11 17,100 202083720 (C,M,V)CG18PB1M 13 11 17,100

Model

Voltage/ Hz/

PhaseVoltage Range

Min. Circuit (Amps)

Max. Fuse

(Amps)1

Compressor Fan Motor

Refrig. Charge (oz.)2

Weight (lbs.)

Rated Load

(Amps)

Locked Rotor

(Amps)Full Load (Amps)

Rated HP

Nom. RPM Louvered

RSG1318 208-230/60/1 197-253 10.9 15 8.1 39 0.7 1/10 1010 62 136

RSG1324 208-230/60/1 197-253 14.1 20 10.7 53 0.7 1/10 1010 63 137

RSG1330 208-230/60/1 197-253 15.6 25 11.6 59 1.1 1/5 1090 82 147

RSG1336 208-230/60/1 197-253 20.1 35 15.2 70 1.1 1/5 1090 84 149

RSG1342 208-230/60/1 197-253 28.1 45 21.1 90 1.7 1/4 825 104 194

RSG1348 208-230/60/1 197-253 31.9 50 24.1 100 1.7 1/4 825 124 192

RSG1360 208-230/60/1 197-253 29.4 60 22.1 120 1.7 1/4 830 144 205

ELECTRICAL AND PHYSICAL DATA

1 Overcurrent protection device2 Factory charge adequate for 15 feet of line set. Adjust per Installation Instructions.

UNIT DIMENSIONS & SOUND RATINGSNote: Dimensions listed are unit sizes w/o packaging

Model

Dimensions

Sound Ratings (dBa)

A - width (in.)

B - depth (in.)

C - height (in.)

RSG1318 24-1/4 24-1/4 25 74

RSG1324 24-1/4 24-1/4 25 74

RSG1330 24-1/4 24-1/4 29 74

RSG1336 24-1/4 24-1/4 29 74

RSG1342 28-1/4 28-1/4 29 79

RSG1348 28-1/4 28-1/4 33 79

RSG1360 28-1/4 28-1/4 29 80

MODEL NUMBER GUIDE

ResidentialCondenser

SplitSystem

CapacityBTUH x 1000

S = Scroll Compressor

Series/ Revision

‘Green’ GasR-410A

Power1 = 208/230-1-60

SEER13, 14, 16

R S G 13 24 S 1 M

Page 3: RSG13**S1M...(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095 (C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178 (C,M,V)CG18PA1M 13 11 17,100 202083720 (C,M,V)CG18PB1M 13 11 17,100

PERFORMANCE WITH COILS, AIR HANDLERS AND FURNACES

Outd

oor

Mod

el Indoor Model

TXV Kit Where Needed Furnace1

Cooling

Evap. CoilAir Handlers1 SEER EER

AHRI Capacity2

AHRI Reference Numbers

RSG1

318S

1M(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095

(C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178

(C,M,V)CG18PA1M 13 11 17,100 202083720

(C,M,V)CG18PB1M 13 11 17,100 202083721

(C,M,V)CG18PC1M 13 11 17,100 202083722

HMG24F1M 13 11 17,600 201925008

HMG24X1M 14 11 17,600 201925010

HMG24V1M 14 11 18,000 201925009

HMG24F1P 13 11 18,000 202833088

HMG24X1P 14 12 18,000 202822068

HCG24V1P 14 12 18,000 202833103

HWCG24T0A 13 10.8 16,800 202887714

HWCG24X0A 14 11 16,200 202887751

HWCG23T0A 13 10.8 16,800 203420589

HWCG23X0A 14 11.7 16,600 203420607

(C,M)CG1824PA1P GUH80C045A3M 14.5 12.2 19,200 204496347

(C,M)CG1824PA1P+TXV H4TXV01 GUH80C045A3M 15 12.5 19,200 204496348

(C,M)CG18PA3P GUH80C045A3M 14.5 12.2 19,500 204496349

(C,M)CG18PA3P+TXV H4TXV01 GUH80C045A3M 15 12.5 19,500 204496350

(C,M)CG24PA4P GUH80C045A3M 14.5 12.2 19,600 204496351

(C,M)CG24PA4P+TXV H4TXV01 GUH80C045A3M 15 12.5 19,600 204496352

(C,M,V)CG18PB1M+TXV 4200 GUH95C045B3M 14 10.8 16,200 202467693

(C,M,V)CG18PB1M GUH95C045B3M 13.5 10.8 16,200 202467695

(C,M)CG1824PB1P GUH92C045B3M 13 11 17,000 204496452

(C,M)CG18PB3P GUH92C045B3M 13 11 17,000 204496453

(C,M)CG24PB4P GUH92C045B3M 13 11 17,000 204496454

(C,M)CG1824PB1P GUH92C070B3M 13 11 17,000 204496455

(C,M)CG18PB3P GUH92C070B3M 13 11 17,000 204496456

(C,M)CG24PB4P GUH92C070B3M 13 11 17,000 204496457

(C,M,V)CG18PB1M GUH95C070B3M 14 11.8 16,200 202467699

(C,M,V)CG18PB1M+TXV 4200 GUH95C070B3M 14.5 11.8 16,200 202467697

(C,M)CG1824PB1P GUH95T045B3M 13 11 17,400 204496306

(C,M)CG1824PB1P+TXV H4TXV01 GUH95T045B3M 14 11.7 17,400 204496307

(C,M)CG18PB3P GUH95T045B3M 14 12 17,600 204496308

(C,M)CG18PB3P+TXV H4TXV01 GUH95T045B3M 14 12 17,600 204496309

(C,M)CG24PB4P GUH95T045B3M 14 12.2 17,600 204496310

(C,M)CG24PB4P+TXV H4TXV01 GUH95T045B3M 14.5 12.2 17,600 204496311

(C,M,V)CG18PB1M GUH95T070B3M 14 11.8 16,200 202467703

(C,M,V)CG18PB1M+TXV 4200 GUH95T070B3M 14.5 11.8 16,200 202467701

(C,M)CG1824PB1P GUH95C045B3M 13 10.5 17,400 203408173

(C,M)CG1824PB1P GUH95C070B3M 13 11 17,400 203408175

(C,M)CG1824PB1P+TXV H4TXV01 GUH95C070B3M 14 11.7 17,400 203408174

+(C,M)CG1824PB1P GUH95T070B3M 13 11 17,400 203408177

(C,M)CG1824PB1P+TXV H4TXV01 GUH95T070B3M 14 11.7 17,400 203408176

(C,M)CG1824PB1P GUH96C045B3M 13 11 17,400 204525161

Note: 1 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all furnaces and AH products 2 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240

CONTINUED ON NEXT PAGE

Page 4: RSG13**S1M...(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095 (C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178 (C,M,V)CG18PA1M 13 11 17,100 202083720 (C,M,V)CG18PB1M 13 11 17,100

PERFORMANCE WITH COILS, AIR HANDLERS AND FURNACES

Note: 1 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all furnaces and AH products 2 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240

Outd

oor

Mod

el Indoor Model

TXV Kit Where Needed Furnace1

Cooling

Evap. CoilAir Handlers1 SEER EER

AHRI Capacity2

AHRI Reference Numbers

RSG1

318S

1M

(C,M)CG1824PB1P+TXV H4TXV01 GUH96C045B3M 14 11.7 17,400 204525162

(C,M)CG18PB3P GUH96C045B3M 14 12 17,600 204525163

(C,M)CG18PB3P+TXV H4TXV01 GUH96C045B3M 14 12 17,600 204708446

(C,M)CG24PB4P GUH96C045B3M 14 12 17,600 204708449

(C,M)CG24PB4P+TXV H4TXV01 GUH96C045B3M 14.5 12 17,600 204708452

(C,M)CG1824PB1P GUH96T045B3M 13 11 17,400 204708440

(C,M)CG1824PB1P+TXV H4TXV01 GUH96T045B3M 14 12 17,400 204708442

(C,M)CG18PB3P GUH96T045B3M 14 12 17,600 204708444

(C,M)CG18PB3P+TXV H4TXV01 GUH96T045B3M 14 12 17,600 204708447

(C,M)CG24PB4P GUH96T045B3M 14 12 17,600 204708450

(C,M)CG24PB4P+TXV H4TXV01 GUH96T045B3M 14.5 12 17,600 204708453

(C,M)CG1824PB1P GUH96T070B3M 13 11 17,400 204708441

(C,M)CG1824PB1P+TXV H4TXV01 GUH96T070B3M 14 12 17,400 204708443

(C,M)CG18PB3P GUH96T070B3M 14 12 17,600 204708445

(C,M)CG18PB3P+TXV H4TXV01 GUH96T070B3M 14 12 17,600 204708448

(C,M)CG24PB4P GUH96T070B3M 14 12 17,600 204708451

(C,M)CG24PB4P+TXV H4TXV01 GUH96T070B3M 14.5 12 17,600 204708454

(C,M)CG1824PB1P GUH97M070B3M 13 11 17,400 204521069

(C,M)CG1824PB1P+TXV H4TXV01 GUH97M070B3M 14 11.7 17,400 204521070

(C,M)CG18PB3P GUH97M070B3M 14 12 17,600 204521071

RSG1

324S

1M

(C,M)CG1824P(A,B,C)1P 13 11 22,800 203408252

(C,M)CG2430P(A,B,C)3P 13 11 22,800 205293963

(C,M,V)CG24/30PA1M 13 10.8 21,200 202467719

(C,M,V)CG24/30PB1M 13 10.8 21,200 202467719

(C,M,V)CG24/30PC1M 13 10.8 21,200 202467719

HMG24F1M 13 11 22,800 201925012

HCG24V1M 14 11 23,000 201925013

HMC30X1M 14 11 22,800 201925014

HMG24F1P 13 11 23,000 202833089

HMG30F1P 13 11 23,000 202833090

HMG24X1P 14 12 23,000 202833095

HMG30X1P 13 11 23,000 204118576

HCG24V1P 14 12 23,000 202833104

HCG30V1P 14 12 23,000 202833105

HWCG24T0A 13 10.8 21,000 202887718

HWCG24X0A 14 11.5 20,400 202887755

HWCG30X0A 14.5 12.3 23,000 202887759

HWCG23T0A 13.5 10.8 21,000 203420625

HWCG23X0A 14 11.6 21,000 203420642

HWCG35X0A 14 11.9 21,600 203420660

(C,M)CG1824PA1P GUH80C045A3M 14 12.2 23,600 204496353

(C,M)CG1824PA1P+TXV H4TXV01 GUH80C045A3M 15 12.2 23,400 204496354

(C,M)CG2430PA3P GUH80C045A3M 14 12.2 23,800 204496355

(C,M)CG2430PA3P+TXV H4TXV01 GUH80C045A3M 15 12.5 23,800 204496356

(C,M)CG24PA4P GUH80C045A3M 14 12.2 24,000 204496357

CONTINUED ON NEXT PAGE

Page 5: RSG13**S1M...(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095 (C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178 (C,M,V)CG18PA1M 13 11 17,100 202083720 (C,M,V)CG18PB1M 13 11 17,100

PERFORMANCE WITH COILS, AIR HANDLERS AND FURNACES

Note: 1 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all furnaces and AH products 2 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240

Outd

oor

Mod

el Indoor Model

TXV Kit Where Needed Furnace1

Cooling

Evap. CoilAir Handlers1 SEER EER

AHRI Capacity2

AHRI Reference Numbers

RSG1

324S

1M(C,M)CG24PA4P+TXV H4TXV01 GUH80C045A3M 15 12.5 24,000 204496358

(C,M)CG30PA5P GUH80C045A3M 14.5 12.2 24,000 204496359

(C,M)CG30PA5P+TXV H4TXV01 GUH80C045A3M 15 12.5 24,000 204496360

(C,M)CG1824PB1P GUH92C045B3M 13 10.5 22,600 204496462

(C,M)CG1824PB1P+TXV H4TXV01 GUH92C045B3M 14 10.5 22,600 204496463

(C,M)CG2430PB3P GUH92C045B3M 14 11 22,800 204496464

(C,M)CG24PB4P GUH92C045B3M 14 11 23,000 204496465

(C,M)CG1824PB1P GUH92C070B3M 13 10.5 22,600 204496466

(C,M)CG1824PB1P+TXV H4TXV01 GUH92C070B3M 14 10.5 22,600 204496467

(C,M)CG2430PB3P GUH92C070B3M 14 11 22,800 204496468

(C,M)CG24PB4P GUH92C070B3M 14 11 23,000 204496469

(C,M,V)CG24/30PB1M GUH95C070B3M 13.5 11.5 20,200 202467709

(C,M,V)CG24/30PB1M+TXV 4200 GUH95C070B3M 14 11.5 20,200 202467707

(C,M)CG1824PB1P GUH95T045B3M 14 12 22,800 204496312

(C,M)CG2430PB3P GUH95T045B3M 14 12.2 22,800 204496313

(C,M)CG2430PB3P+TXV H4TXV01 GUH95T045B3M 14.5 12.2 22,800 204496314

(C,M)CG24PB4P GUH95T045B3M 14 12.2 22,800 204496315

(C,M)CG24PB4P+TXV H4TXV01 GUH95T045B3M 14.5 12.2 22,800 204496316

(C,M)CG30PB5P GUH95T045B3M 14 12.2 22,800 204496317

(C,M)CG30PB5P+TXV H4TXV01 GUH95T045B3M 14.5 12.2 22,800 204496318

(C,M,V)CG24/30PB1M GUH95T070B3M 13.5 11.5 20,200 202467713

(C,M,V)CG24/30PB1M+TXV 4200 GUH95T070B3M 14 11.5 20,200 202467711

(C,M,V)CG24/30PC1M GUH95T090C3M 13.5 11.6 20,600 202467717

(C,M,V)CG24/30PC1M+TXV 4200 GUH95T090C3M 14.5 11.6 20,600 202467715

(C,M)CG1824PB1P GUH95C070B3M 13 11 22,800 203408221

(C,M)CG1824PB1P+TXV H4TXV01 GUH95C070B3M 14 11.7 22,400 203408220

(C,M)CG1824PB1P GUH95T070B3M 14 12 22,800 203408223

(C,M)CG1824PB1P+TXV H4TXV01 GUH95T070B3M 14 12 22,800 203408222

(C,M)CG1824PC1P GUH95T090C3M 13 11 22,000 203408225

(C,M)CG1824PC1P+TXV H4TXV01 GUH95T090C3M 14 11.7 22,000 203408224

(C,M)CG1824PB1P GUH96C045B3M 14 12.2 23,200 204525164

(C,M)CG1824PB1P+TXV H4TXV01 GUH96C045B3M 14.5 12.2 23,200 204525165

(C,M)CG2430PB3P GUH96C045B3M 14 12.2 23,600 204525166

(C,M)CG2430PB3P+TXV H4TXV01 GUH96C045B3M 14.5 12.2 23,600 204525167

(C,M)CG24PB4P GUH96C045B3M 14 12.2 23,800 204525168

(C,M)CG24PB4P+TXV H4TXV01 GUH96C045B3M 15 12.5 23,800 204525169

(C,M)CG1824PB1P GUH96C070B3M 14 12.2 23,400 204525170

(C,M)CG1824PB1P+TXV H4TXV01 GUH96C070B3M 14.5 12.2 23,400 204525171

(C,M)CG2430PB3P GUH96C070B3M 14 12.2 23,800 204525172

(C,M)CG2430PB3P+TXV H4TXV01 GUH96C070B3M 15 12.2 23,800 204525173

(C,M)CG24PB4P GUH96C070B3M 14 12.2 24,000 204525174

(C,M)CG24PB4P+TXV H4TXV01 GUH96C070B3M 15 12.5 24,000 204525175

(C,M)CG1824PB1P GUH96T045B3M 14 12 23,600 204708455

(C,M)CG1824PB1P+TXV H4TXV01 GUH96T045B3M 15 12 23,600 204708457

(C,M)CG2430PB3P GUH96T045B3M 14.5 12 23,800 204708459

CONTINUED ON NEXT PAGE

Page 6: RSG13**S1M...(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095 (C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178 (C,M,V)CG18PA1M 13 11 17,100 202083720 (C,M,V)CG18PB1M 13 11 17,100

PERFORMANCE WITH COILS, AIR HANDLERS AND FURNACES

Note: 1 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all furnaces and AH products 2 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240

Outd

oor

Mod

el Indoor Model

TXV Kit Where Needed Furnace1

Cooling

Evap. CoilAir Handlers1 SEER EER

AHRI Capacity2

AHRI Reference Numbers

RSG1

324S

1M

(C,M)CG2430PB3P+TXV H4TXV01 GUH96T045B3M 15 13 24,000 204708461

(C,M)CG24PB4P GUH96T045B3M 14.5 12 23,800 204708463

(C,M)CG24PB4P+TXV H4TXV01 GUH96T045B3M 15 13 24,200 204708465

(C,M)CG1824PB1P GUH96T070B3M 14.5 12 23,800 204708456

(C,M)CG1824PB1P+TXV H4TXV01 GUH96T070B3M 15 13 23,800 204708458

(C,M)CG2430PB3P GUH96T070B3M 14.5 12 24,000 204708460

(C,M)CG2430PB3P+TXV H4TXV01 GUH96T070B3M 15 13 24,000 204708462

(C,M)CG24PB4P GUH96T070B3M 15 13 24,000 204708464

(C,M)CG24PB4P+TXV H4TXV01 GUH96T070B3M 15 13 24,000 204708466

(C,M)CG1824PC1P GUH96T090C3M 14.5 12 23,800 204708467

(C,M)CG1824PC1P+TXV H4TXV01 GUH96T090C3M 15 12 23,800 204708468

(C,M)CG2430PC3P GUH96T090C3M 14.5 12 24,000 204708469

(C,M)CG2430PC3P+TXV H4TXV01 GUH96T090C3M 15 12 24,000 204708470

(C,M)CG24PC4P GUH96T090C3M 15 12 24,000 204708471

(C,M)CG24PC4P+TXV H4TXV01 GUH96T090C3M 15 12 24,000 204708472

(C,M)CG1824PB1P GUH97M070B3M 14 12.2 23,400 204521072

(C,M)CG1824PB1P+TXV H4TXV01 GUH97M070B3M 15 12.2 23,400 204521073

(C,M)CG2430PB3P GUH97M070B3M 14 12.2 23,800 204521074

(C,M)CG2430PB3P+TXV H4TXV01 GUH97M070B3M 15 12.5 23,800 204521075

(C,M)CG24PB4P GUH97M070B3M 14 12.2 24,000 204521076

(C,M)CG24PB4P+TXV H4TXV01 GUH97M070B3M 15 12.5 24,000 204521077

(C,M)CG1824PC1P GUH97M090C3M 13 11 22,000 204521078

(C,M)CG1824PC1P+TXV H4TXV01 GUH97M090C3M 14 11.7 22,000 204521079

(C,M)CG2430PC3P GUH97M090C3M 13 11 22,400 204521080

(C,M)CG2430PC3P+TXV H4TXV01 GUH97M090C3M 14 11.7 22,400 204521081

(C,M)CG24PC4P GUH97M090C3M 13 11 22,600 204521082

(C,M)CG24PC4P+TXV H4TXV01 GUH97M090C3M 14 12 22,600 204521083

RSG1

330S

1M

(C,M)CG2430P(A,B,C)3P 13 11 28,000 204094096

(C,M)CG30P(A,B,C)2P+TXV H4TXV01 13 10.5 27,600 203408363

(C,M)CG3036P(A,B,C)4P 13 11 28,000 205783248

(C,M)CG3036P(A,B,C)4P+TXV H4TXV01 13 11 28,000 205783249

(C,M)CG3036T(A,B,C)4P 13 11 28,000 205788540

(C,M,V)CG24/30PA1M 13 10.5 26,000 202467741

(C,M,V)CG24/30PB1M 13 10.5 26,000 202467741

(C,M,V)CG24/30PC1M 13 10.5 26,000 202467741

HMG30F1M 13 11 28,000 201925016

HMG30X1M 14 11 28,000 201925017

HCG36V1M 14 11 29,000 201925018

HMG36F1P 13 11 28,000 202833091

HMG30X1P 14 11 28,000 202833096

HMG36X1P 14 11 28,000 202833097

HCG30V1P 14 11 28,000 202833106

HCG36V1P 14 12 28,000 202833107

HWCG30X0A 14.5 11.3 28,200 202887762

CONTINUED ON NEXT PAGE

Page 7: RSG13**S1M...(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095 (C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178 (C,M,V)CG18PA1M 13 11 17,100 202083720 (C,M,V)CG18PB1M 13 11 17,100

PERFORMANCE WITH COILS, AIR HANDLERS AND FURNACES

Note: 1 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all furnaces and AH products 2 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240

Outd

oor

Mod

el Indoor Model

TXV Kit Where Needed Furnace1

Cooling

Evap. CoilAir Handlers1 SEER EER

AHRI Capacity2

AHRI Reference Numbers

RSG1

330S

1MHWCG35T0A 13.5 11 26,800 203420677

HWCG35X0A 14 10.8 26,000 203420695

HWCG36T0A 13.5 10.9 26,200 202887722

(C,M)CG30PA2P GUH80C045A3M 13 11 28,800 204496361

(C,M)CG30PA2P+TXV H4TXV01 GUH80C045A3M 14 12 28,800 204496362

(C,M)CG2430PA3P GUH80C045A3M 14 12 28,800 204496363

(C,M)CG2430PA3P+TXV H4TXV01 GUH80C045A3M 14.5 12.2 29,400 204496364

(C,M)CG30PA5P GUH80C045A3M 14 12.2 29,600 204496365

(C,M)CG30PA5P+TXV H4TXV01 GUH80C045A3M 15 12.2 29,600 204496366

(C,M,V)CG24/30PB1M GUH95C045B3M 13 10.5 24,600 202467723

(C,M,V)CG24/30PB1M+TXV 4200 GUH95C045B3M 13.5 10.5 24,600 202467721

(C,M)CG30PB2P GUH92C045B3M 13 10.5 27,600 204496474

(C,M)CG2430PB3P GUH92C045B3M 13 11 29,000 204496475

(C,M)CG3036PB4P GUH92C045B3M 13 11 29,000 204496476

(C,M)CG30PB5P GUH92C045B3M 13 11 29,000 204496477

(C,M)CG30PB5P+TXV H4TXV01 GUH92C045B3M 14 11 29,000 204496478

(C,M)CG30PB2P GUH92C070B3M 13 10.5 27,600 204496479

(C,M)CG2430PB3P GUH92C070B3M 13 11 29,000 204496480

(C,M)CG3036PB4P GUH92C070B3M 13 11 29,000 204496481

(C,M)CG30PB5P GUH92C070B3M 13 11 29,000 204496482

(C,M)CG30PB5P+TXV H4TXV01 GUH92C070B3M 14 11 29,000 204496483

(C,M,V)CG24/30PB1M GUH95C070B3M 13 10.5 24,600 202467727

(C,M,V)CG24/30PB1M+TXV 4200 GUH95C070B3M 13.5 10.5 24,600 202467725

(C,M)CG2430PB3P GUH95T045B3M 13 11 28,000 204496319

(C,M)CG2430PB3P+TXV H4TXV01 GUH95T045B3M 14 11 28,000 204496320

(C,M)CG3036PB4P GUH95T045B3M 13 11 28,000 204496321

(C,M)CG3036PB4P+TXV H4TXV01 GUH95T045B3M 14 11.5 28,000 204496322

(C,M)CG30PB5P GUH95T045B3M 14 11.5 28,000 204496323

(C,M,V)CG24/30PB1M GUH95T070B3M 13 10.5 24,600 202467735

(C,M,V)CG24/30PB1M+TXV 4200 GUH95T070B3M 13.5 10.5 24,600 202467733

(C,M,V)CG24/30PB1M GUH95C090C4M 13 10.6 25,200 202467731

(C,M,V)CG24/30PB1M+TXV 4200 GUH95C090C4M 14 10.6 25,200 202467729

(C,M,V)CG24/30PB1M GUH95T090C3M 13 10.6 25,200 202467739

(C,M,V)CG24/30PB1M+TXV 4200 GUH95C090C3M 14 10.6 25,200 202467737

(C,M)CG2430PB3P+TXV H4TXV01 GUH95C045B3M 14 11 28,000 203408316

(C,M)CG30PB2P GUH95C045B3M 13 10.5 27,600 203408315

(C,M)CG2430PB3P+TXV H4TXV01 GUH95C070B3M 14 11 28,000 203408318

(C,M)CG30PB2P GUH95C070B3M 13 10.5 27,600 203408317

(C,M)CG2430PC3P GUH95C090C4M 13 11 28,000 203408319

(C,M)CG30PC5P+TXV H4TXV01 GUH95C090C4M 14 11 28,000 203408320

(C,M)CG2430PB3P+TXV H4TXV01 GUH95T070B3M 14 11 28,000 203408322

(C,M)CG30PB2P GUH95T070B3M 13 10.5 27,600 203408321

(C,M)CG2430PC3P GUH95T090C3M 13 11 28,000 203408323

(C,M)CG30PC5P+TXV H4TXV01 GUH95T090C3M 14 11 28,000 203408324

CONTINUED ON NEXT PAGE

Page 8: RSG13**S1M...(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095 (C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178 (C,M,V)CG18PA1M 13 11 17,100 202083720 (C,M,V)CG18PB1M 13 11 17,100

PERFORMANCE WITH COILS, AIR HANDLERS AND FURNACES

Note: 1 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all furnaces and AH products 2 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240

Outd

oor

Mod

el Indoor Model

TXV Kit Where Needed Furnace1

Cooling

Evap. CoilAir Handlers1 SEER EER

AHRI Capacity2

AHRI Reference Numbers

RSG1

330S

1M

(C,M)CG2430PB3P GUH96C045B3M 13 11 29,000 204525177

(C,M)CG2430PB3P+TXV H4TXV01 GUH96C045B3M 14 11 29,000 204525178

(C,M)CG3036PB4P GUH96C045B3M 13 11 29,400 204525179

(C,M)CG3036PB4P+TXV H4TXV01 GUH96C045B3M 14 11.5 29,400 204525180

(C,M)CG30PB2P GUH96C045B3M 13 10.5 27,800 204525176

(C,M)CG30PB5P GUH96C045B3M 13 11 29,400 204525181

(C,M)CG30PB2P+TXV H4TXV01 GUH96C045B3M 14 12 28,000 204708475

(C,M)CG30PB2P+TXV H4TXV01 GUH96C070B3M 13 11 27,800 204708476

(C,M)CG30PB5P+TXV H4TXV01 GUH96C045B3M 14 11.7 29,400 204525182

(C,M)CG2430PB3P GUH96C070B3M 13 11 29,000 204525184

(C,M)CG2430PB3P+TXV H4TXV01 GUH96C070B3M 14 11.7 29,000 204525185

(C,M)CG3036PB4P GUH96C070B3M 13 11 29,400 204525186

(C,M)CG3036PB4P+TXV H4TXV01 GUH96C070B3M 14 12 29,400 204525187

(C,M)CG30PB2P GUH96C070B3M 13 11 27,800 204525183

(C,M)CG30PB5P GUH96C070B3M 13 11 29,400 204525188

(C,M)CG30PB5P+TXV H4TXV01 GUH96C070B3M 14 12.2 29,400 204525189

(C,M)CG2430PC3P GUH96C090C4M 13 11 29,000 204525192

(C,M)CG2430PC3P+TXV H4TXV01 GUH96C090C4M 14.5 11.7 29,000 204525193

(C,M)CG3036PC4P GUH96C090C4M 13 11 29,400 204525194

(C,M)CG3036PC4P+TXV H4TXV01 GUH96C090C4M 14.5 12 29,400 204525195

(C,M)CG30PC2P GUH96C090C4M 13 11 27,800 204525190

(C,M)CG30PC2P+TXV H4TXV01 GUH96C090C4M 14 11 27,800 204525191

(C,M)CG30PC5P GUH96C090C4M 13 11 29,400 204525196

(C,M)CG30PC5P+TXV H4TXV01 GUH96C090C4M 14.5 12.2 29,400 204525197

(C,M)CG30PB2P GUH96T045B3M 13 11 28,200 204708473

(C,M)CG30PB2P+TXV H4TXV01 GUH96T045B3M 14 12 28,200 204708477

(C,M)CG2430PB3P GUH96T045B3M 14 12 28,800 204708479

(C,M)CG2430PB3P+TXV H4TXV01 GUH96T045B3M 14.5 12 29,200 204708481

(C,M)CG3036PB4P GUH96T045B3M 14 12 29,200 204708483

(C,M)CG3036PB4P+TXV H4TXV01 GUH96T045B3M 14.5 12 29,200 204708485

(C,M)CG30PB5P GUH96T045B3M 14 12 29,200 204708487

(C,M)CG30PB5P+TXV H4TXV01 GUH96T045B3M 15 12 29,400 204708489

(C,M)CG30PB2P GUH96T070B3M 13 11 28,200 204708474

(C,M)CG30PB2P+TXV H4TXV01 GUH96T070B3M 14.5 12 27,800 204708478

(C,M)CG2430PB3P GUH96T070B3M 14 12 29,000 204708480

(C,M)CG2430PB3P+TXV H4TXV01 GUH96T070B3M 14.5 12 29,200 204708482

(C,M)CG3036PB4P GUH96T070B3M 14 12 29,400 204708484

(C,M)CG3036PB4P+TXV H4TXV01 GUH96T070B3M 15 12 29,400 204708486

(C,M)CG30PB5P GUH96T070B3M 14 12 29,800 204708488

(C,M)CG30PB5P+TXV H4TXV01 GUH96T070B3M 15 13 29,800 204708490

(C,M)CG30PC2P GUH96T090C3M 14 12 28,400 204708491

(C,M)CG30PC2P+TXV H4TXV01 GUH96T090C3M 14.5 12 28,400 204708492

(C,M)CG2430PC3P GUH96T090C3M 14 12 29,400 204708493

(C,M)CG2430PC3P+TXV H4TXV01 GUH96T090C3M 15 13 29,400 204708494

CONTINUED ON NEXT PAGE

Page 9: RSG13**S1M...(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095 (C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178 (C,M,V)CG18PA1M 13 11 17,100 202083720 (C,M,V)CG18PB1M 13 11 17,100

PERFORMANCE WITH COILS, AIR HANDLERS AND FURNACES

Note: 1 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all furnaces and AH products 2 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240

Outd

oor

Mod

el Indoor Model

TXV Kit Where Needed Furnace1

Cooling

Evap. CoilAir Handlers1 SEER EER

AHRI Capacity2

AHRI Reference Numbers

RSG1

330S

1M(C,M)CG3036PC4P GUH96T090C3M 14.5 12 29,400 204708495

(C,M)CG3036PC4P+TXV H4TXV01 GUH96T090C3M 15 13 29,400 204708496

(C,M)CG30PC5P GUH96T090C3M 14.5 12 29,400 204708497

(C,M)CG30PC5P+TXV H4TXV01 GUH96T090C3M 15 13 29,400 204708498

(C,M)CG30PB2P GUH97M070B3M 13 11 27,800 204521084

(C,M)CG30PB2P+TXV H4TXV01 GUH97M070B3M 14 11.7 27,800 204521085

(C,M)CG2430PB3P GUH97M070B3M 14 12.2 29,000 204521086

(C,M)CG2430PB3P+TXV H4TXV01 GUH97M070B3M 14.5 12.2 29,000 204521087

(C,M)CG3036PB4P GUH97M070B3M 14 12.2 29,400 204521088

(C,M)CG3036PB4P+TXV H4TXV01 GUH97M070B3M 15 12.2 29,400 204521089

(C,M)CG30PB5P GUH97M070B3M 14 12.2 29,800 204521090

(C,M)CG30PB5P+TXV H4TXV01 GUH97M070B3M 15 12.5 29,800 204521091

(C,M)CG30PC2P GUH97M090C3M 13 11 27,800 204521092

(C,M)CG30PC2P+TXV H4TXV01 GUH97M090C3M 14.5 12 27,800 204521093

(C,M)CG2430PC3P GUH97M090C3M 14 12.2 29,000 204521094

(C,M)CG2430PC3P+TXV H4TXV01 GUH97M090C3M 15 12.5 29,000 204521095

(C,M)CG3036PC4P GUH97M090C3M 14 12.2 29,200 204521096

(C,M)CG3036PC4P+TXV H4TXV01 GUH97M090C3M 15 12.5 29,200 204521097

(C,M)CG30PC5P GUH97M090C3M 14 12.2 29,200 204521098

(C,M)CG30PC5P+TXV H4TXV01 GUH97M090C3M 15 12.5 29,200 204521099

RSG1

336S

1M

(C,M)CG36P(A,B,C)7P 13 10.5 33,800 204094097

(C,M)CG3036P(A,B,C)4P+TXV H4TXV02 13 10 33,000 203408364

(C,M,V)CG36PA1M 13 10.4 31,800 202467763

(C,M,V)CG36PB1M 13 10.4 31,800 202467763

(C,M,V)CG36PC1M 13 10.4 31,800 202467763

HMG36F1M 13 10.5 34,000 201925020

HMG36X1M 14 11 34,000 201925021

HCG36V1M 13.5 11 34,000 201925022

HMG42F1P 13 10.5 34,200 202833092

HMG36X1P 13 11 35,000 202833098

HCG36V1P 13 11 34,200 202833108

HCG42V1P 13 11 35,000 202833115

HWCG36T0A 13.5 10.3 31,600 202887726

HWCG42X0A 14.5 11.2 33,800 202887767

HWCG35T0A 13.5 10.3 31,400 203420712

HWCG35X0A 14 10.8 31,400 203420730

HWCG47X0A 14.5 11 33,000 203420747

(C,M)CG3036PA4P GUH80C045A3M 13 10.5 34,600 204496367

(C,M)CG36PA7P GUH80C045A3M 13 11 35,400 204496368

(C,M)CG36PA7P+TXV H4TXV02 GUH80C045A3M 14 11 35,400 204496369

(C,M)CG3036PB4P GUH92C045B3M 13 10 33,000 204496484

(C,M)CG36PB7P GUH92C045B3M 13 10.5 33,800 204496485

(C,M)CG3036PB4P GUH92C070B3M 13 10 33,000 204496486

(C,M)CG36PB7P GUH92C070B3M 13 10.5 33,800 204496487

(C,M)CG3036PC4P+TXV H4TXV02 GUH92C090C3M 13 10 32,600 204496488

CONTINUED ON NEXT PAGE

Page 10: RSG13**S1M...(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095 (C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178 (C,M,V)CG18PA1M 13 11 17,100 202083720 (C,M,V)CG18PB1M 13 11 17,100

PERFORMANCE WITH COILS, AIR HANDLERS AND FURNACES

Note: 1 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all furnaces and AH products 2 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240

Outd

oor

Mod

el Indoor Model

TXV Kit Where Needed Furnace1

Cooling

Evap. CoilAir Handlers1 SEER EER

AHRI Capacity2

AHRI Reference Numbers

RSG1

336S

1M

(C,M)CG36PC7P GUH92C090C3M 13 10 33,400 204496489

(C,M)CG3036PC4P GUH92C110C4M 13 10 32,600 204496490

(C,M)CG36PC7P GUH92C110C4M 13 10 33,400 204496491

(C,M)CG36PC7P GUH92C110C5M 13 10 33,400 204496492

(C,M,V)CG36PC1M GUH95T090C3M 13.5 10.8 31,800 202467753

(C,M,V)CG36PC1M+TXV 4200 GUH95T090C3M 14 10.8 31,800 202467751

(C,M,V)CG36PC1M GUH95C090C4M 13.5 10.8 31,800 202467743

(C,M,V)CG36PC1M+TXV 4200 GUH95C090C4M 14 10.8 31,800 202467745

(C,M,V)CG36PC1M GUH95T090C5M 13.5 10.8 31,800 202467756

(C,M,V)CG36PC1M+TXV 4200 GUH95T090C5M 14 10.8 31,800 202467754

(C,M,V)CG36PC1M GUH95T110C5M 13.5 10.8 31,800 202467761

(C,M,V)CG36PC1M+TXV 4200 GUH95T110C5M 14 10.8 31,800 202467759

(C,M)CG3036PC4P GUH95C090C4M 13 10.5 32,800 203408325

(C,M)CG36PC7P+TXV H4TXV02 GUH95C090C4M 13 11 33,800 203408226

(C,M)CG3036PC4P GUH95C110C5M 13 10.5 32,800 203408326

(C,M)CG36PC7P+TXV H4TXV02 GUH95C110C5M 13 11 33,800 203408227

(C,M)CG3036PC4P GUH95T090C3M 13 10.5 32,800 203408327

(C,M)CG36PC7P+TXV H4TXV02 GUH95T090C3M 13 11 33,800 203408228

(C,M)CG3036PC4P GUH95T090C5M 13 10.5 32,800 203408328

(C,M)CG36PC7P+TXV H4TXV02 GUH95T090C5M 13 11 33,800 203408229

(C,M)CG3036PC4P GUH95T110C5M 13 10.5 32,800 203408329

(C,M)CG36PC7P+TXV H4TXV02 GUH95T110C5M 13 11 33,800 203408230

(C,M)CG36PB7P+TXV H4TXV02 GUH96C045B3M 13 11 35,000 204525198

(C,M)CG3036PB4P GUH96C070B3M 13 10.5 34,800 204525199

(C,M)CG36PB7P GUH96C070B3M 13 11 35,200 204525200

(C,M)CG36PB7P+TXV H4TXV02 GUH96C070B3M 14 11 35,200 204525201

(C,M)CG3036PC4P GUH96C090C4M 13 11 34,600 204525202

(C,M)CG36PC7P GUH96C090C4M 13 11 35,400 204525203

(C,M)CG36PC7P+TXV H4TXV02 GUH96C090C4M 14 11.5 34,600 204525204

(C,M)CG3036PC4P GUH96C110C5M 13 10.5 32,800 204525205

(C,M)CG36PC7P GUH96C110C5M 13 11 35,600 204525206

(C,M)CG36PC7P+TXV H4TXV02 GUH96C110C5M 14 11.7 35,200 204525207

(C,M)CG3036PB4P+TXV H4TXV02 GUH96C070B3M 13 11 34,800 204708501

(C,M)CG3036PC4P+TXV H4TXV02 GUH96C090C4M 13 11 34,600 204708510

(C,M)CG3036PC4P+TXV H4TXV02 GUH96C110C5M 13 11 33,600 204708511

(C,M)CG3036PB4P GUH96T045B3M 13 11 34,200 204708499

(C,M)CG36PB7P GUH96T045B3M 13 11 35,000 204708503

(C,M)CG36PB7P+TXV H4TXV02 GUH96T045B3M 14 11 35,000 204708505

(C,M)CG3036PB4P GUH96T070B3M 13 11 34,400 204708500

(C,M)CG3036PB4P+TXV H4TXV02 GUH96T070B3M 13 11 34,400 204708502

(C,M)CG36PB7P GUH96T070B3M 13 11 35,200 204708504

(C,M)CG36PB7P+TXV H4TXV02 GUH96T070B3M 14 11 35,200 204708506

(C,M)CG3036PC4P GUH96T090C3M 13 11 34,800 204708507

(C,M)CG3036PC4P+TXV H4TXV02 GUH96T090C3M 14 11 34,800 204708512

(C,M)CG36PC7P GUH96T090C3M 13 11 35,600 204708515

CONTINUED ON NEXT PAGE

Page 11: RSG13**S1M...(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095 (C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178 (C,M,V)CG18PA1M 13 11 17,100 202083720 (C,M,V)CG18PB1M 13 11 17,100

PERFORMANCE WITH COILS, AIR HANDLERS AND FURNACES

Note: 1 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all furnaces and AH products 2 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240

Outd

oor

Mod

el Indoor Model

TXV Kit Where Needed Furnace1

Cooling

Evap. CoilAir Handlers1 SEER EER

AHRI Capacity2

AHRI Reference Numbers

RSG1

336S

1M(C,M)CG36PC7P+TXV H4TXV02 GUH96T090C3M 14 12 34,600 204708518

(C,M)CG3036PC4P GUH96T090C5M 13 11 33,000 204708508

(C,M)CG3036PC4P+TXV H4TXV02 GUH96T090C5M 13 11 33,600 204708513

(C,M)CG36PC7P GUH96T090C5M 13 11 34,000 204708516

(C,M)CG3036PC4P GUH96T110C5M 13 11 33,000 204708509

(C,M)CG3036PC4P+TXV H4TXV02 GUH96T110C5M 13 11 33,600 204708514

(C,M)CG36PC7P GUH96T110C5M 13 11 34,000 204708517

(C,M)CG3036PB4P GUH97M070B3M 13 10.5 34,200 204521100

(C,M)CG36PB7P GUH97M070B3M 13 10.5 35,000 204521101

(C,M)CG3036PC4P GUH97M090C3M 13 10.5 34,400 204521102

(C,M)CG36PC7P GUH97M090C3M 13 11 33,800 204521103

(C,M)CG3036PC4P GUH97M090C4M 13 10.5 34,400 204521104

(C,M)CG36PC7P GUH97M090C4M 13 11 33,800 204521105

(C,M)CG3036PC4P GUH97M090C5M 13 10.5 33,000 204521106

(C,M)CG36PC7P GUH97M090C5M 13 11 33,800 204521107

(C,M)CG3036PC4P GUH97M110C5M 13 10.5 33,000 204521108

(C,M)CG36PC7P GUH97M110C5M 13 11 35,600 204521109

(C,M)CG36PC7P+TXV H4TXV02 GUH97M110C5M 14 11.7 35,600 204521110

RSG1

342S

1M

(C,M)CG4248P(B,C,D)8P 13 10.5 40,000 204094099

(C,M)CG42P(B,C,D)6P+TXV H4TXV02 13 10.5 39,000 203408253

(C,M)CG4248P(B,C,D)8P+TXV H4TXV02 13 10.5 40,000 205783250

(C,M)CG4248T(B,C,D)8P 13 10.5 40,000 205788541

(C,M,V)CG42PB1M 13 10.1 34,600 202467775

(C,M,V)CG42PC1M 13 10.1 34,600 202467775

(C,M,V)CG42PD1M 13 10.1 34,600 202467775

HMG42F1M 13 11 40,000 201925024

HMG42X1M 14 11 40,000 201925025

HMG42V1M 14 11 40,000 201925026

HMG42X1P 13 11 42,000 202833099

HCG42V1P 13 11 42,000 202833109

HCG48V1P 14 12 42,000 202833110

HWCG42X0A 14.5 11 39,000 202887770

HWCG48T0A 13 10.7 36,600 202887730

HWCG48X0A 14.5 11 39,000 202887773

HWCG47T0A 13.5 11 38,500 203420765

HWCG47X0A 14 10.9 38,000 203420783

(C,M)CG4248PC8P GUH92C090C3M 13 11 42,000 204496493

(C,M)CG42PC6P GUH92C090C3M 13 10.5 41,500 204496494

(C,M)CG4248PCBP GUH92C090C3M 13 11 42,000 204496495

(C,M)CG4248PCBP+TXV H4TXV02 GUH92C090C3M 14 11.5 42,000 204496496

(C,M)CG4248PC8P GUH92C110C4M 13 11 42,000 204496497

(C,M)CG42PC6P GUH92C110C4M 13 10.5 41,500 204496498

(C,M)CG4248PCBP GUH92C110C4M 13 11 42,000 204496499

(C,M)CG4248PCBP+TXV H4TXV02 GUH92C110C4M 14 11.5 42,000 204496500

(C,M)CG4248PC8P GUH92C110C5M 13 11 42,000 204496501

CONTINUED ON NEXT PAGE

Page 12: RSG13**S1M...(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095 (C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178 (C,M,V)CG18PA1M 13 11 17,100 202083720 (C,M,V)CG18PB1M 13 11 17,100

Outd

oor

Mod

el Indoor Model

TXV Kit Where Needed Furnace1

Cooling

Evap. CoilAir Handlers1 SEER EER

AHRI Capacity2

AHRI Reference Numbers

RSG1

342S

1M

(C,M)CG42PC6P GUH92C110C5M 13 10.5 41,500 204496502

(C,M)CG4248PCBP GUH92C110C5M 13 11 42,000 204496503

(C,M)CG4248PCBP+TXV H4TXV02 GUH92C110C5M 14 11.5 42,000 204496504

(C,M,V)CG42PC1M GUH95T090C5M 13 10.4 34,600 202467769

(C,M,V)CG42PC1M+TXV 4202 GUH95T090C5M 13.5 10.4 34,600 202467767

(C,M,V)CG42PC1M+TXV 4202 GUH95C110C5M 13.5 10.4 34,600 202467765

(C,M,V)CG42PC1M GUH95T110C5M 13 10.4 34,600 202467773

(C,M,V)CG42PC1M+TXV 4202 GUH95T110C5M 13.5 10.4 34,600 202467771

(C,M)CG42PC6P GUH95C110C5M 13 10.5 39,000 203408231

(C,M)CG42PC6P GUH95T090C5M 13 10.5 39,500 203408232

(C,M)CG42PC6P GUH95T110C5M 13 10.5 39,500 203408233

(C,M)CG4248PC8P GUH96C090C4M 13 11 41,500 204525208

(C,M)CG4248PC8P+TXV H4TXV02 GUH96C090C4M 14 11.5 41,500 204525209

(C,M)CG4248PCBP GUH96C090C4M 13 11 42,000 204525211

(C,M)CG4248PCBP+TXV H4TXV02 GUH96C090C4M 14 12 41,500 204525212

(C,M)CG42PC6P GUH96C090C4M 13 11 40,500 204525210

(C,M)CG4248PC8P GUH96C110C5M 13 11 42,000 204525213

(C,M)CG4248PC8P+TXV H4TXV02 GUH96C110C5M 14 11.5 42,000 204525215

(C,M)CG4248PCBP GUH96C110C5M 13 11 42,500 204525217

(C,M)CG4248PCBP+TXV H4TXV02 GUH96C110C5M 14 12 42,000 204525218

(C,M)CG42PC6P GUH96C110C5M 13 11 41,000 204525216

(C,M)CG4248PB8P+TXV H4TXV02 GUH96T070B3M 13 11 41500 204708519

(C,M)CG4248PC8P GUH96T090C3M 13 11 40000 204708520

(C,M)CG42PC6P+TXV H4TXV02 GUH96T090C3M 13 11 39500 204708527

(C,M)CG4248PCBP GUH96T090C3M 13 11 41500 204708530

(C,M)CG4248PCBP+TXV H4TXV02 GUH96T090C3M 14 12 41500 204708533

(C,M)CG4248PC8P GUH96T090C5M 13 11 42000 204708521

(C,M)CG4248PC8P+TXV H4TXV02 GUH96T090C5M 14 12 42000 204708523

(C,M)CG42PC6P GUH96T090C5M 13 11 41500 204708525

(C,M)CG42PC6P+TXV H4TXV02 GUH96T090C5M 14 11 39500 204708528

(C,M)CG4248PCBP GUH96T090C5M 13 11 42000 204708531

(C,M)CG4248PCBP+TXV H4TXV02 GUH96T090C5M 14.5 12 41500 204708534

(C,M)CG4248PC8P GUH96T110C5M 13 11 42000 204708522

(C,M)CG4248PC8P+TXV H4TXV02 GUH96T110C5M 14 12 42000 204708524

(C,M)CG42PC6P GUH96T110C5M 13 11 41000 204708526

(C,M)CG42PC6P+TXV H4TXV02 GUH96T110C5M 14 11 39500 204708529

(C,M)CG4248PCBP GUH96T110C5M 13 11 42000 204708532

(C,M)CG4248PCBP+TXV H4TXV02 GUH96T110C5M 14.5 12 41500 204708535

(C,M)CG4248PC8P GUH97M090C4M 13 11 41,500 204521111

(C,M)CG4248PC8P+TXV H4TXV02 GUH97M090C4M 14 11.5 41,500 204521112

(C,M)CG42PC6P GUH97M090C4M 13 11 40,500 204521113

(C,M)CG4248PCBP GUH97M090C4M 13 11 41,500 204521114

(C,M)CG4248PCBP+TXV H4TXV02 GUH97M090C4M 14 12 41,500 204521115

(C,M)CG4248PC8P GUH97M090C5M 13 11 41,500 204521116

(C,M)CG4248PC8P+TXV H4TXV02 GUH97M090C5M 14 11.5 41,500 204521117

Note: 1 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all furnaces and AH products 2 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240

CONTINUED ON NEXT PAGE

PERFORMANCE WITH COILS, AIR HANDLERS AND FURNACES

Page 13: RSG13**S1M...(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095 (C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178 (C,M,V)CG18PA1M 13 11 17,100 202083720 (C,M,V)CG18PB1M 13 11 17,100

Outd

oor

Mod

el Indoor Model

TXV Kit Where Needed Furnace1

Cooling

Evap. CoilAir Handlers1 SEER EER

AHRI Capacity2

AHRI Reference Numbers

RSG1

342S

1M(C,M)CG42PC6P GUH97M090C5M 13 11 40,500 204521118

(C,M)CG4248PCBP GUH97M090C5M 13 11 41,500 204521119

(C,M)CG4248PCBP+TXV H4TXV02 GUH97M090C5M 14 12 41,500 204521120

(C,M)CG4248PC8P GUH97M110C5M 13 11 41,500 204521121

(C,M)CG4248PC8P+TXV H4TXV02 GUH97M110C5M 14 11.5 41,500 204521122

(C,M)CG42PC6P GUH97M110C5M 13 11 40,500 204521123

(C,M)CG4248PCBP GUH97M110C5M 13 11 41,500 204521124

(C,M)CG4248PCBP+TXV H4TXV02 GUH97M110C5M 14 12 41,500 204521125

RSG1

348S

1M

(C,M)CG4248P(C,D)BP 13 11 47,000 204094100

(C,M)CG4248P(B,C,D)8P+TXV H4TXV02 13 10.5 45,500 203408365

(C,M,V)CG48PB1M 13 10.8 43,500 202467777

(C,M,V)CG48PC1M 13 10.8 43,500 202467777

(C,M,V)CG48PD1M 13 10.8 43,500 202467777

HMG48F1M 13 11 47,000 201925028

HMG48X1M 14 11 47,000 201925029

HCG48V1M 14 11 47,000 201925030

HMG48X1P 13 11 48,000 204118577

HCG48V1P 13 11 48,000 204118578

HWCG48T0A 13 10 42,500 202887734

HWCG48X0A 14 10.9 44,500 202887778

HWCG60T0A 13 10.7 43,000 202887739

HWCG60X0A 14 10.9 44,500 202887781

HWCG47T0A 13.5 10.8 43,500 203420801

HWCG47X0A 14 10.8 43,500 203420818

(C,M)CG48PB9P+TXV H4TXV02 GUH80C090B4M 13 11 48,000 204623519

(C,M)CG4248PCBP GUH80C090C5M 14 11.7 49,500 204623521

(C,M)CG48PC9P GUH80C090C5M 13 11 48,500 204623520

(C,M)CG60PCAP+TXV H4TXV02 GUH80C090C5M 14 11.7 50,000 204623522

(C,M)CG4248PCBP GUH80C110C5M 14 12.2 48,000 204623524

(C,M)CG48PC9P GUH80C110C5M 13 11 48,500 204623523

(C,M)CG60PCAP+TXV H4TXV02 GUH80C110C5M 14 12.2 48,000 204623525

(C,M)CG4248PDBP GUH80C135D5M 14 11.7 49,500 204623527

(C,M)CG48PD9P GUH80C135D5M 13 11 48,500 204623526

(C,M)CG60PDAP+TXV H4TXV02 GUH80C135D5M 14 11.7 49,500 204623528

(C,M)CG4248PC8P GUH92C090C3M 13 11 48,000 204496505

(C,M)CG48PC9P GUH92C090C3M 13 11 48,000 204496506

(C,M)CG48PC9P+TXV H4TXV02 GUH92C090C3M 14 11 48,000 204496507

(C,M)CG48PCCP GUH92C090C3M 13 11 48,000 204496508

(C,M)CG48PCCP+TXV H4TXV02 GUH92C090C3M 14 11.5 48,000 204496509

(C,M)CG4248PCBP GUH92C090C3M 13 11 48,000 204496510

(C,M)CG4248PCBP+TXV H4TXV02 GUH92C090C3M 14 11.5 48,000 204496511

(C,M)CG4248PC8P GUH92C110C4M 13 11 48,000 204496512

(C,M)CG48PC9P GUH92C110C4M 13 11 48,000 204496513

(C,M)CG48PC9P+TXV H4TXV02 GUH92C110C4M 14 11 48,000 204496514

(C,M)CG48PCCP GUH92C110C4M 13 11 48,000 204496515

Note: 1 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all furnaces and AH products 2 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240

CONTINUED ON NEXT PAGE

PERFORMANCE WITH COILS, AIR HANDLERS AND FURNACES

Page 14: RSG13**S1M...(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095 (C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178 (C,M,V)CG18PA1M 13 11 17,100 202083720 (C,M,V)CG18PB1M 13 11 17,100

Outd

oor

Mod

el Indoor Model

TXV Kit Where Needed Furnace1

Cooling

Evap. CoilAir Handlers1 SEER EER

AHRI Capacity2

AHRI Reference Numbers

RSG1

348S

1M(C,M)CG48PCCP+TXV H4TXV02 GUH92C110C4M 14 11.5 48,000 204496516

(C,M)CG4248PCBP GUH92C110C4M 13 11 48,000 204496517

(C,M)CG4248PCBP+TXV H4TXV02 GUH92C110C4M 14 11.5 48,000 204496518

(C,M)CG4248PC8P GUH92C110C5M 13 11 48,000 204496519

(C,M)CG48PC9P GUH92C110C5M 13 11 48,000 204496520

(C,M)CG48PC9P+TXV H4TXV02 GUH92C110C5M 14 11 48,000 204496521

(C,M)CG48PCCP GUH92C110C5M 13 11 48,000 204496522

(C,M)CG48PCCP+TXV H4TXV02 GUH92C110C5M 14 11.5 48,000 204496523

(C,M)CG4248PCBP GUH92C110C5M 13 11 48,000 204496524

(C,M)CG4248PCBP+TXV H4TXV02 GUH92C110C5M 14 11.5 48,000 204496525

(C,M)CG4248PCBP GUH95C090C4M 14 11.7 49,500 204623530

(C,M)CG48PC9P GUH95C090C4M 13 11 48,500 204623529

(C,M)CG60PCAP+TXV H4TXV02 GUH95C090C4M 14 11.7 50,000 204623531

(C,M)CG4248PCBP GUH95C110C5M 14 11.7 49,500 204623533

(C,M)CG48PC9P GUH95C110C5M 13 11 48,500 204623532

(C,M)CG60PCAP+TXV H4TXV02 GUH95C110C5M 14 11.7 50,000 204623534

(C,M)CG4248PDBP GUH95C135D5M 13 11 48,000 204623535

(C,M)CG60PDAP+TXV H4TXV02 GUH95C135D5M 13 11 48,000 204623536

(C,M)CG4248PC8P+TXV H4TXV02 GUH96C090C4M 13 11 48,000 204525219

(C,M)CG4248PCBP+TXV H4TXV02 GUH96C090C4M 13 11 49,500 204525222

(C,M)CG48PC9P+TXV H4TXV02 GUH96C090C4M 13 11 48,000 204525220

(C,M)CG48PCCP+TXV H4TXV02 GUH96C090C4M 13 11 50,000 204525221

(C,M)CG4248PC8P GUH96C110C5M 13 11 48,000 204525223

(C,M)CG4248PCBP GUH96C110C5M 13 11 49,500 204525227

(C,M)CG4248PCBP+TXV H4TXV02 GUH96C110C5M 14 11.7 49,500 204525228

(C,M)CG48PC9P GUH96C110C5M 13 11 48,500 204525224

(C,M)CG48PCCP GUH96C110C5M 13 11 50,000 204525225

(C,M)CG48PCCP+TXV H4TXV02 GUH96C110C5M 14 11.7 50,000 204525226

(C,M)CG4248PB8P+TXV H4TXV02 GUH96C090B3M 13 11 48,000 204708537

(C,M)CG48PB9P+TXV H4TXV02 GUH96C090B3M 13 11 48,000 204708539

(C,M)CG4248PB8P GUH96C110B3M 13 11 48,000 204708536

(C,M)CG48PB9P GUH96C110B3M 13 11 48,500 204708538

(C,M)CG4248PC8P+TXV H4TXV02 GUH96C110C5M 13 11 48,000 204708542

(C,M)CG48PC9P+TXV H4TXV02 GUH96C110C5M 13 11 48,500 204708545

(C,M)CG60PCBP GUH96C110C5M 13 11 49,500 204708552

(C,M)CG60PCBP+TXV H4TXV02 GUH96C110C5M 14 12 49,500 204708553

(C,M)CG4248PC8P GUH96T090C5M 13 11 48,000 204708540

(C,M)CG48PC9P GUH96T090C5M 13 11 48,500 204708543

(C,M)CG48PCCP GUH96T090C5M 13 11 50,000 204708546

(C,M)CG48PCCP+TXV H4TXV02 GUH96T090C5M 14 12 50,000 204708548

(C,M)CG4248PC8P GUH96T110C5M 13 11 48,000 204708541

(C,M)CG48PC9P GUH96T110C5M 13 11 48,500 204708544

(C,M)CG48PCCP GUH96T110C5M 13 11 50,000 204708547

(C,M)CG48PCCP+TXV H4TXV02 GUH96T110C5M 14 12 50,000 204708549

(C,M)CG4248PCBP GUH96T110C5M 13 11 49,500 204708550

(C,M)CG4248PCBP+TXV H4TXV02 GUH96T110C5M 14 12 49,500 204708551

Note: 1 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all furnaces and AH products 2 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240

CONTINUED ON NEXT PAGE

PERFORMANCE WITH COILS, AIR HANDLERS AND FURNACES

Page 15: RSG13**S1M...(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095 (C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178 (C,M,V)CG18PA1M 13 11 17,100 202083720 (C,M,V)CG18PB1M 13 11 17,100

Outd

oor

Mod

el Indoor Model

TXV Kit Where Needed Furnace1

Cooling

Evap. CoilAir Handlers1 SEER EER

AHRI Capacity2

AHRI Reference Numbers

RSG1

348S

1M(C,M)CG4248PD8P GUH96T135D5M 13 11 48,500 204708554

(C,M)CG4248PD8P+TXV H4TXV02 GUH96T135D5M 13 11 48,500 204708555

(C,M)CG48PD9P GUH96T135D5M 13 11 49,000 204708556

(C,M)CG48PD9P+TXV H4TXV02 GUH96T135D5M 13 11 49,000 204708557

(C,M)CG48PDCP GUH96T135D5M 13 11 50,000 204708558

(C,M)CG48PDCP+TXV H4TXV02 GUH96T135D5M 14 12 50,000 204708559

(C,M)CG4248PDBP GUH96T135D5M 13 11 50,000 204708560

(C,M)CG4248PDBP+TXV H4TXV02 GUH96T135D5M 14 12 50,000 204708561

(C,M)CG4248PC8P GUH97M090C4M 13 11 47,500 204521126

(C,M)CG48PC9P GUH97M090C4M 13 11 48,000 204521127

(C,M)CG48PCCP GUH97M090C4M 13 11 49,500 204521128

(C,M)CG48PCCP+TXV H4TXV02 GUH97M090C4M 14 11.7 49,500 204521129

(C,M)CG4248PCBP GUH97M090C4M 13 11 49,000 204521130

(C,M)CG4248PCBP+TXV H4TXV02 GUH97M090C4M 14 11.7 49,000 204521131

(C,M)CG4248PC8P GUH97M090C5M 13 11 48,000 204521132

(C,M)CG48PC9P GUH97M090C5M 13 11 48,500 204521133

(C,M)CG48PCCP GUH97M090C5M 13 11 50,000 204521134

(C,M)CG48PCCP+TXV H4TXV02 GUH97M090C5M 14 11.7 50,000 204521135

(C,M)CG4248PCBP GUH97M090C5M 13 11 49,500 204521136

(C,M)CG4248PCBP+TXV H4TXV02 GUH97M090C5M 14 11.7 49,500 204521137

(C,M)CG4248PC8P GUH97M110C5M 13 11 48,000 204521138

(C,M)CG48PC9P GUH97M110C5M 13 11 48,500 204521139

(C,M)CG48PCCP GUH97M110C5M 13 11 50,000 204521140

(C,M)CG48PCCP+TXV H4TXV02 GUH97M110C5M 14 11.7 50,000 204521141

(C,M)CG4248PCBP GUH97M110C5M 13 11 49,500 204521142

(C,M)CG4248PCBP+TXV H4TXV02 GUH97M110C5M 14 11.7 49,500 204521143

(C,M)CG4248PD8P GUH97M135D5M 13 11 47,500 204521144

(C,M)CG48PD9P GUH97M135D5M 13 11 48,000 204521145

(C,M)CG48PDCP GUH97M135D5M 13 11 49,000 204521146

(C,M)CG48PDCP+TXV H4TXV02 GUH97M135D5M 14 11.7 49,000 204521147

(C,M)CG4248PDBP GUH97M135D5M 13 11 49,000 204521148

(C,M)CG4248PDBP+TXV H4TXV02 GUH97M135D5M 14 11.7 49,000 204521149

RSG1

360S

1M

(C,M)CG60P(C,D)BP 13 10.5 57,000 204094101

(C,M)CG60P(C,D)AP+TXV H4TXV03 13 10.5 56,500 203408254

(C,M,V)CG60PC1M 13 10.5 53,000 202467779

(C,M,V)CG60PD1M 13 10.5 53,000 202467779

HMG60F1M 13 11 56,000 201925032

HMG60X1M 13.5 11 56,000 201925033

HCG60V1M 13.5 11 57,000 201925034

HMG60F1P 13 11 58,000 202833093

HMG60X1P 13 11 58,000 202833102

HCG60V1P 13 10.5 58,000 202833113

HWCG60T0A 13 10.4 48,500 202887743

HWCG60X0A 14 10.9 52,500 202887785

(C,M)CG60PCAP GUH92C110C5M 13 10.5 55,500 204496526

(C,M)CG60PCBP GUH92C110C5M 13 11 56,500 204496527

Note: 1 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all furnaces and AH products 2 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240

PERFORMANCE WITH COILS, AIR HANDLERS AND FURNACES

Page 16: RSG13**S1M...(C,M)CG18P(A,B,C)3P 13 11 17,600 204094095 (C,M)CG1824P(A,B,C)1P+TXV H4TXV01 13 10.5 17,400 203408178 (C,M,V)CG18PA1M 13 11 17,100 202083720 (C,M,V)CG18PB1M 13 11 17,100

ACCESSORIES

DESCRIPTION WHERE USED CATALOG NUMBER

Crankcase Heater 18, 24, 30, 36 93M04

Crankcase Heater 42, 48, 60 93M05

Hard Start Kit 18 10J42

Hard Start kit 24, 30, 36, 42, 48, 60 88M91

Compressor Low Ambient Kit 18, 24, 30, 36, 42, 48, 60 34M72

Sound Blanket18, 24, 30, 36 14W00

42, 48, 60 14W01

Short Cycle Protector 18, 24, 30, 36, 42, 48, 60 47J27

Freezestat 3/8" tubing 93G35

Freezestat 5/8" tubing 50A93

Time Delay Relay 18, 24, 30, 36, 42, 48, 60 58M81

Loss of Charge Kit 18, 24, 30, 36, 42, 48, 60 84M23

TXV Kit 18 - 30 H4TXV01

TXV Kit 36 - 48 H4TXV02

TXV Kit 60 H4TXV03

TXV Kit 18 - 36 4200

TXV Kit 42 - 60 4202

SP-2M 6/20 CA-RSG13M_SPEC

Due to ongoing product improvements, specifications and dimensions are subject to change and correction without notice or incurring obligations. Determining the application and suitability for use of any product is the responsibility of the installer.

Additionally, the installer is responsible for verifying dimensional data on the actual product prior to beginning any installation preparations.Third party incentive and rebate programs have precise requirements as to product performance and certification. All products meet applicable regulations in effect on date of manufacture; however, certifications are not necessarily granted for the life of a product.

Therefore, it is the responsibility of the applicant to determine whether a specific model qualifies for these incentive/rebate programs.

RSG13**S1M