CTI16 Manual V15.4 April 2014 Page 3/20
Contents
Pre-installation checks & safety procedures 4 Introduction 5 Unpacking 5 Technical Specification 6 CTI/16 & CTI/8 Software version history 6 Test Mode 7 Setting the protocol & baud rate 8 Address setting 9 Advanced features table 10 CTI/16 Connection details 11 Diagnostic LEDs 12 Intellex DVR controlling domes up the coax via CTI/16 telemetry interface 13 DVX to CTI/16 driving RX100/VCL 14 Vicon matrix controlling CTI/16 with 360 Vision domes 15 2060 Dennard domes with up the coax control & 4 local alarms 16 Philips Bi-Phase matrix to CTI/16 driving an RX55X 17
CTI16 Manual V15.4 April 2014 Page 4/20
PRE-INSTALLATION CHECKS AND SAFETY PROCEDURES
Unpacking - Inspect the packaging for signs of damage. If damage has occurred, advise the carrier and/or the suppliers immediately. Unpack the receiver carefully and check that all the items are present and correct (see checklist on box). If any item is missing contact the supplier.
Retain packaging - The shipping carton is the safest container in which to transport the unit. Retain undamaged packaging for possible future use.
IMPORTANT SAFETY PRECAUTIONS
Read & retain instructions - All relevant safety, installation and operating instructions should be read & retained before attempting to install, connect or operate the unit.
Water and moisture - Do not expose the internal electronics of this unit to water or dampness.
Power sources - This unit should be operated only from the supplied power supply.
Servicing - Servicing of the unit should only be undertaken by qualified service personnel.
Damage requiring service - Servicing by qualified personnel should be carried out under the following conditions:
(a) When the power supply cord or plug is damaged; (b) If liquid has been spilled, or objects have fallen into, the unit; (c) If the internal electronics of the unit have been exposed to rain or water; (d) If the unit does not operate normally by following the operating instructions. (e) If the unit has been dropped or the enclosure is damaged;
Replacement parts - If replacement parts are required, ensure that only replacement parts recommended by the product manufacturer are used.
Safety check - Upon completion of any service or repairs to the unit, safety checks should be performed to ensure that the unit is in proper operating condition.
Coax grounding - If an outside cable system is connected to the unit, be sure the cable system is grounded.
Pre-installation checks - It is recommended that the unit be bench-tested prior to installation on the site.
Adhere to Safety Standards - All normal safety precautions as laid down by British Standards and the Health and Safety at Work Act should be observed.
WARNING TO PREVENT DANGER OF FIRE OR SHOCK, DO NOT EXPOSE THE INTERNAL COMPONENTS OF THIS EQUIPMENT TO RAIN OR MOISTURE.
CTI16 Manual V15.4 April 2014 Page 5/20
INTRODUCTION
GENERAL The CTI/16 is designed to provide conversion from RS422/485 data to BBV Coax Telemetry based systems. Up the Coax telemetry allows upgrading of static cameras to PTZ without the need for additional cabling. One RS422/485 input that is dipswitch selectable. The Baud Rates & Parity for Pelco P/D & Vicon Protocols are variable. Sixteen individual outputs are provided. Each output connects to a single receiver. Each unit is supplied with a break out box and 0.5mtr Cat 6 patch cable. Multiple CTI/16 can be cascaded together giving up to 256 camera outputs.
Please Note: Camera address will be limited to the maximum number supported by the individual
protocol.
Please note: Menu Access commands of cameras can vary between control equipment even if using
the same protocol.
For Example: In Pelco D protocol - dome menu access commands can be either Goto Preset 95 or
Save Preset 95. Enter = Goto Preset 1 or Iris Open / Close Protocols currently supported are:
BBV,
Pelco P/D,
Pelco P DM,
VCL,
Dennard,
Philips,
Sensormatic RS422,
Molynx,
Vicon. The CTI/16 has been tested with the BBV FBM/256 Matrix & Starcard Converter, BBV TX1500/96 Matrix & Starcard Converter, Pelco KBD300, DM DS2, VCL VCTM16 Matrix & Maxcom 8 Matrix & Keyboard, Philips Allegiant 32 Camera Matrix LTC8301/50 & Bi – Phase to RS232 Converter LTC8780/50, American Dynamics Intellex LT V4 Software, Molynx TTX600 Keyboard & TTX6164T Matrix and Vicon VI411-DVC Keyboard
Unpacking
Inspect the packaging for signs of damage. If damage has occurred, advise the carriers and/or the suppliers immediately. Unpack the interface carefully and check all the items are included:
CTI/16 RS422/BBV Coax Telemetry Interface 16 channel X
CAT6 patch cable X
Break out box X
Mounting brackets X
9 to 12Vdc PSU X
Manual X
CTI16 Manual V15.4 April 2014 Page 6/20
Technical Specification
Power Requirements 9 to 12Vdc PSU 500mA
Inputs 2 Wire RS485, 2 Wire RS422 Simplex and 4 Wire Full Duplex (switch selectable input protocol) Maximum Cable Distance Belden 8723 = 1200m
Outputs 16 x BBV Coax Telemetry Maximum Cable Distance RG59 = 250m CT125 = 500m
Supported Protocols
Facilities LED as power indication
Boxed Dimensions Supplied in 19” 1 U rack mountable case Length 425mm
Depth 110mm Height 43mm
Installation The unit is designed to either be fitted into a 19” rack or wall mounted via the fixing brackets supplied
CTI/16 Manual & Software Version History Version 15.4 April 2014 -1. Updated layout to Protocols pages 5&6 -2. Visio drawings updated from Rx100 to Rx10X Version 15.2 June 2010 -1. Change to the Test mode page Version 15A June 2010 -1. Change to the Sensormatic commands on page 9 Version 15 11 December 2009 -1. Added Test feature. Pan Left & Right via dipswitches Version 1 8 May 2008 - 1. CTI/8 Released Version 13 15 October 2007 -1. Bug fix for address 27 in Dennard RS485 Protocol Version 12 10 October 2007 -1. Bug fix for address 2 & 3 in Dennard RS485 Protocol Version 11 3 September 2007 -1. Updated Support of VCL Telemetry from Maxcom 8 Matrix -2. Manual Update Version 10 15 August 2007 -1. Bug fix of VCL Telemetry from Maxcom 8 Matrix Version 9 10 July 2007 -1. Updated Support of VCL Telemetry from Maxcom 8 Matrix Version 8 17 March 2007 -1. Updated support of Hash Command release time
-2. Manual update. Version 7 13 February 2007 -1. Added continuous sending of telemetry for legacy coax receivers Version 6 8 January 2007 - 1. Molynx Protocol Speed table recalibration Version 5 11 December 2006 - 1. Bug fix for Accumulative Delays in Pelco P & D and Dennard RS485 Routines
- 2. Updated watchdog routine - 3. Added support for Sensormatic RS422 Protocol - 4. Added support for Molynx RS485 Protocol - 5. Added support for Vicon RS485 Protocol variable Baud Rate
Version 4 18 November 2005 - 1. Added support for Pelco P/D Protocol variable Baud Rate & Parity settings. - 2. Added support for Pelco P DM Auxiliary outputs.
Version 3 27 June 2005 - 1. Added support for Dennard 2050 Protocol. Version 2 25 May 2005 - 1. Added support for Philips RS485 Protocol. Version 1 11 November 2005 - 1. CTI/16 Released
Support of BBV, Dennard, Philips, Pelco P & D and VCL RS485 input protocols converting to BBV Coax output protocol.
BBV422 9600
Pelco P 2400, 4800 & 9600
Pelco P DM 2400, 4800 & 9600
Pelco D 2400, 4800 & 9600
VCL 9600
Dennard 9600
Philips 9600
Sensormatic 4800
Molynx 9600
Vicon 4800, 9600, 19200
CTI16 Manual V15.4 April 2014 Page 7/20
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
SW1 Cam 1 Pan Left SW1 Cam 2 Pan Left
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
This feature enables the Camera to be driven left or right from the Coax Telemetry Interface directly
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
SW2 Sets Test Mode SW1 Sets Camera Number &
Direction
SW1 Cam 3 Pan Left
SW1 Cam 4 Pan Left SW1 Cam 5 Pan Left SW1 Cam 6 Pan Left
SW1 Cam 7 Pan Left SW1 Cam 8 Pan Left SW1 Cam 9 Pan Left
SW1 Cam 10 Pan Left SW1 Cam 11 Pan Left SW1 Cam 12 Pan Left
SW1 Cam 13 Pan Left SW1 Cam 14 Pan Left SW1 Cam 15 Pan Left
SW1 Cam 16 Pan Left
7 ON = Pan Left
8 ON = Pan Right
7 81 2 3 54 6
ON
75 7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
Test Mode
CTI16 Manual V15.4 April 2014 Page 8/20
Setting the Protocol and baud rate
Input Termination
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
SW2 BBV 9600 N 8 1 SW2 Pelco P 9600 N 8 1
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
The CTI/16 will only output BBV Coax Telemetry on the 16 Coax output channels
The CTI/16 supports various RS422/485 input Protocols
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
SW2 Sets Protocol & Baud Rate SW1 Sets Address & Parity
SW2 Pelco P 4800 N 8 1
SW2 Pelco P 2400 N 8 1 SW2 Pelco P DM 9600 N 8 1 SW2 Pelco P DM 4800 N 8 1
SW2 Pelco P DM 2400 N 8 1 SW2 Pelco D 9600 N 8 1 SW2 Pelco D 4800 N 8 1
SW2 Pelco D 2400 N 8 1 SW2 VCL 9600 N 8 1 SW2 Dennard 9600 N 8 1
SW2 Philips 9600 N 8 1
7 81 2 3 54 6
ON
75
SW2 Sensormatic 4800 N 8 2
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
SW2 Molynx 9600 E 8 1
SW2 Vicon 19200 N 8 1 SW2 Vicon 9600 N 8 1 SW2 Vicon 4800 N 8 1
7 & 8 OFF = None Parity
7 & 8 ON = Odd Parity
7 OFF & 8 ON = Even Parity
CTI16 Manual V15.4 April 2014 Page 9/20
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
7 81 2 3 54 6
ON
SW1 Sets Address
Address Settings
The CTI/16 supports a maximum of 256 addresses
A maximum of 16 x CTI/16 can be cascaded togetherN.B. Refer to input Protocol documents for maximum address supported
i.e. Pelco P max addr = 32
Address Range 1 - 16
Address Range 17 - 32 Address Range 33 - 48 Address Range 49 - 64
Address Range 65 - 80 Address Range 81 - 96 Address Range 97 - 112
Address Range 113 - 128 Address Range 129 - 144 Address Range 145 - 160
Address Range 161 - 176 Address Range 177 - 192 Address Range 193 - 208
Address Range 209 - 224 Address Range 225 - 241 Address Range 242 - 256
CTI16 Manual V15.4 April 2014 Page 10/20
Advanced Features Table
BBV COAX OUTPUT
1# 2# 3# 4# START 1 PATROL
START 2 PATROL
START AUTOPAN
BBV Tx1500
1# 2# 3# 4# 1 PATROL 2 PATROL
AUTOPAN
PELCO SAVE PRESET 95
OR GOTO PRESET 61
GOTO PRESET 33 OR GOTO PRESET 62
GOTO PRESET 94 OR
GOTO PRESET 63 GOTO PRESET 64
GOTO PRESET 66
GOTO PRESET 67
GOTO PRESET 68
VCL GOTO PRESET 95
OR GOTO PRESET 61
GOTO PRESET 62 GOTO PRESET 63 GOTO PRESET 64 GOTO
PRESET 66 GOTO
PRESET 67 GOTO PRESET
67
DENNARD SAVE PRESET 95
OR GOTO PRESET 61
GOTO PRESET 33 OR GOTO PRESET 62
GOTO PRESET 94 OR
GOTO PRESET 63 GOTO PRESET 64
GOTO PRESET 66
GOTO PRESET 67
GOTO PRESET 67
PHILIPS AUX 46 ON
OR GOTO PRESET 61
AUX 63 ON OR
GOTO PRESET 62
AUX 100 ON/OFF OR
GOTO PRESET 63
SET 899 OR
GOTO PRESET 64
GOTO PRESET 66
GOTO PRESET 67
GOTO PRESET 67
SENSORMATIC
START PATTERN 3 REPEATED 5 TIMES
FOLLOWED BY SAVE PRESET 1
OR GOTO PRESET 61
SEE note 1
START PATTERN 3 REPEATED 5 TIMES
FOLLOWED BY SAVE PRESET 1
OR GOTO PRESET 62
SEE note 1
START PATTERN 3 REPEATED 5 TIMES
FOLLOWED BY SAVE PRESET 1
OR GOTO PRESET 63
SEE note 1
START PATTERN 3 REPEATED 5 TIMES
FOLLOWED BY SAVE PRESET 2
OR GOTO PRESET 64
SEE note 1
GOTO PRESET 71
GOTO PRESET 72
GOTO PRESET 73
MOLYNX AUX 1
OR GOTO PRESET 61
AUX 2 OR
GOTO PRESET 62
HOME OR
GOTO PRESET 63
CAMERA On/Off OR
GOTO PRESET 64
GOTO PRESET 66
GOTO PRESET 67
GOTO PRESET 67
VICON
SAVE PRESET 94 OR 95
OR GOTO PRESET 61
GOTO PRESET 62 GOTO PRESET 63 GOTO PRESET 64 GOTO
PRESET 66 GOTO
PRESET 67 GOTO PRESET
67
NOTE1. 5min time out / Goto Preset 6 to Cancel
When using BBV422 & Pelco P you can toggle wash, wipe & lights with Goto Preset commands:
Preset 81 Wash on, Preset 82 Wash off, Preset 83 Wipe on, Preset 84 Wipe off, Preset 85 Lights on & Preset 86 Lights off.
CTI16 Manual V15.4 April 2014 Page 11/20
CTI/16 Connection Details The CTI/16 unit is supplied with a Cat 6 Patch cable and a Break Out Box.
RED
BLACK
ORANGE
GREEN
YELLOW
BROWN
WHITE
1 =NC(CAT5) WHITE/ORANGE
2 =NC(CAT5) ORANGE
3 = RXA (TO Controller)(CAT5) WHITE/GREEN
4 = TXA (FROM Controller)(CAT5) BLUE
TXB (FROM Controller) = 5(CAT5) WHITE/BLUE
RXB (TO Controller) = 6(CAT5) GREEN
Gnd = 7(CAT5) WHITE/BROWN
Gnd = 8(CAT5) BROWN
RJ45 Surface Socket
FARNELL No 454-485
BLUE
Connection information
TXA (FROM Controller) DATA + from the DVR/ MATRIX to CTI16
TXB (FROM Controller) DATA - from the DVR/ MATRIX to CTI16
RXA (TO Controller) DATA + to the DVR/ MATRIX from CTI16
RXB (TO Controller) DATA - to the DVR/ MATRIX from CTI16
see RS422 NOTE
RS422 NOTE Some systems require RS422 FULL DUPLEX before they will work. Some Sensormatic systems require a 4 Wire connection.
CTI16 Manual V15.4 April 2014 Page 12/20
Diagnostic LEDs
02008 iss 3
Bit 7 Tx Termination
Bit 8 Rx TerminationBBVJ9
LD1 LD2 LD3 LD4 LD5 LD6 LD7 LD8
LD10
J19
12345678
ON
12345678
ON
SW1SW2
12345678
ON
12345678
ON
SW1SW2
SW2 BBV422 SW1 Address Range 1 - 16
LD10
LD 1-8
If there are no video sources you will see
LD1 to 8 flash in sequence.
When a video source is applied to either
input the associated LED will be on
constantly.
LD 10
LD10 will flash when the CTI/16 is
sending data to the coax driver chips,
even if there are no video sources. This
is a good way to test if the CTI/16 is
connected and configured correctly.
RS
422/485 PO
RT
PO
WE
R LE
D
PO
WE
R IN
PU
T 9 - 12 D
C 500m
A
CTI16 Manual V15.4 April 2014 Page 13/20
BBV Intellex Kit
CTI16
16 Camera Coax
Telemetry Interface
RG59 <250M
CT125 <500M
Coax from DomeRS485 to Dome
Edgeport/1
USB Converter
R
XL
OH
IT
X
Rx10X Per Dome
Please note this is a small selection of the domes that can be controlled by the
BBV Rx10X . For a full list of dome please refer to the BBV website
www.bbvcctv.com. It is important that the Rx10X must be close to the dome
within 5 meter is recommended. The CTI Card can control the full range of
BBV Coax Receivers
Rx200
AC output, Wash, Wipe, Lights for static cameras
Rx300
AC output, Pan/Tilt/Zoom/Focus + choice of Wash, Wipe, Lights or Autopan,
Random Pan.
Rx400P
AC output, Pan/Tilt/Zoom/Focus/Iris, Wash, Wipe, Lights, Autopan, 16 presets,
Preset patrol
Rx45X
Advanced Telemetry Receiver – fixed speed AC P/T head. 16 presets, 8 alarm
inputs, OSD programming menu. Remote gain control. Selectable between
230Vac or 110Vac supply. 12Vdc 500mA camera supply output. Links
selectable mains or 24Vac output. Wash, Wipe, Lights and Autopan outputs.
Rx55X
As Rx45X to drive 24Vdc high/variable speed P/T head. Wash, Wipe and
Lights outputs.
LG Domes
JVC
TX_C676 Pelco Domes Pelco Esprit Bosch Domes
Panasonic
Vicon
Surveyor
Sensormatic
VCL
Honeywell
CBC C-All
View
Dennard
Domes
CBC C-ViewVIDECON
Borsatec
BT2790FF
Vista
Powerdome
Samsung
CTI16 Manual V15.4 April 2014 Page 14/20
CTI/16
Pelco D 2400 N 8 1 RS422 Simplex
OR
Pelco D 2400 E 8 1 RS422 Simplex
DVX
DVX to CTI/16 driving Rx10X
Rx10X
LAN
IP SWITCH
LAN
Coax
Tw
iste
d P
air R
S4
22
Sim
ple
x
Max Distance Coax
RG59=250mtrs
CT125=500mtrs
VCL Dome
Rx10X to
Dome Max
Distance 5mtrs
PC with DVX Viwer
CTI16 Manual V15.4 April 2014 Page 15/20
VICON KEYBOARD NETWORK
COAX
VICON SIMPLEX
Coax Distance 250M RG59 500M CT125
VICON MATRIX CONTROLLING CTI16 WITH 360 VISION DOMES
CTI16 Manual V15.4 April 2014 Page 16/20
CTI16
control to
Domes
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 B-BUS PORT
BBV SUPPLY ONLY
9VDC 500mA MAX
Rx10X/WBX
25
0M
RG
59
/ 5
00
M C
T1
25
RS422
LTC8780/50
RS232 kit
BiPHASE
2060 Dennard Domes with up the coax control and 4 local alarms
CTI16 Manual V15.4 April 2014 Page 17/20
Rx55X Multiple
protocol telemetry
receiver
R
XT
X
RS
23
2
CTI/16
Philips Bi-Phase Matrix
Philips Kbd
CoaxPhilips G3 Dome
Bi-Phase
Bi-Phase
Philips Bi-Phase Matrix to CTI/16 driving Rx55X
Coax
RS232 kit
Coax
Max Distance Coax
RG59=250m
CT125=500m
RS
42
2 S
IMP
LE
X
CTI16 Manual V15.4 April 2014 Page 18/20
Up to 250m RG59
Up to 500m CT125
Control Location
CAMERAS
7654321 8 1
MONITOR
ALARM INPUTS
KBD1RS23212V DCTWISTED
PAIR
13 12
12
11 10 9 8 7 6
25 24 23 22 21 20 19 18 17 16 15 14
5 4 3 2 1
MAXCOM8VCL
P A 7020C
20" C o lo r M on ito r
B DATA - n
B DATA + n
BBV CTI/16
BBV Rx10XBBV VA1
Pins Facing away from
you
NOT USED
NOT USED
NOT USED
DATA + DATA -
NOT USED
GND
GREENRED
YELLOWBLACK
ORANGE
BLUE WHITE
BROWN
X DATA - n
X DATA + n
GN
D.
Twisted Pair Plug
Camera Location
GND
CTI16 Manual V15.4 April 2014 Page 20/20
Extend your BBV Warranty from 12 months to 3 years
As of the 1st September 2008 BBV have offered our
customers the opportunity to extend the standard 12 month warranty to 3 years. You must register for the extended warranty within 12 months of the date of manufacture.
How to register for the 3 year warranty
Or alternatively: Register online at: www.bbvcctv.com Simply enter your details on the ‘Warranty Cover’ page.
Registering for the new, longer 3 year warranty term is quick and easy. Either: Complete the warranty application card that comes in the box with your BBV product, and return it FREEPOST to BBV:
VAT Reg. No. 621758439 Registered in England No. 2852921 Registered office: 17 Apex Park Diplocks Way Hailsham East Sussex UK BN27 3JU
If this card is returned with the serial number of the product and the Installation company
details BBV will extend the warranty period from 12 Months to 36 Months.
I do not require any other further product information,
BBV 3 Year Warranty
Please could you send me information
especially on:
Rx100s
Rx45x & Rx55x
FBM Video Matrices
Tx1500 Video Matrices
Starcard & Starcard Converters
BBV Quad
Pick A Point
Please refer to WWW.BBVCCTV.COM for terms, conditions & exclusions
Contact Name.
Company Name.
Phone Number.
Site Name.
Address 1.
Address 2.
Address 3.
e-mail address.
Post Code.
Do you read.
Number of Units, Start Serial No. Final Serial No.