r&s rto/rtp-zf1 usb compliance test fixture · 2019-10-13 · r&s rtp, or r&s rto...

10
R&S ® RT-ZF1 USB 2.0 Compliance Test Fixture Set Manual Manual Version 07 1317432602 (=A[J2)

Upload: others

Post on 21-May-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: R&S RTO/RTP-ZF1 USB Compliance Test Fixture · 2019-10-13 · R&S RTP, or R&S RTO oscilloscope with 4 channels and at least 2 GHz band-width. For full speed and low speed compliance

R&S®RT-ZF1USB 2.0 Compliance TestFixture SetManual

Manu

al

Versi

on 07

1317432602(=A[J2)

Page 2: R&S RTO/RTP-ZF1 USB Compliance Test Fixture · 2019-10-13 · R&S RTP, or R&S RTO oscilloscope with 4 channels and at least 2 GHz band-width. For full speed and low speed compliance

This manual describes the R&S RT-ZF1 USB 2.0 Compliance Test Fixture Set(1317.3420.02).

© 2019 Rohde & Schwarz GmbH & Co. KGMühldorfstr. 15, 81671 München, GermanyPhone: +49 89 41 29 - 0Fax: +49 89 41 29 12 164Email: [email protected]: www.rohde-schwarz.comSubject to change – Data without tolerance limits is not binding.

R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG.Trade names are trademarks of the owners.

Throughout this manual, products from Rohde & Schwarz are indicated without the ® symbol, e.g.R&S®RT-ZF1 is indicated as R&S RT-ZF1.

Page 3: R&S RTO/RTP-ZF1 USB Compliance Test Fixture · 2019-10-13 · R&S RTP, or R&S RTO oscilloscope with 4 channels and at least 2 GHz band-width. For full speed and low speed compliance

Safety InformationR&S®RT-ZF1

3Manual 1317.4326.02 07

1 Safety InformationThe product documentation helps you to use the product safely and efficiently.Keep the product documentation nearby and offer it to other users.

Safety information warns you about the potential dangers and gives instructionshow to prevent personal injuries or damage caused by dangerous situations.Throughout the documentation, safety instructions are provided when you need totake care during setup or operation.

Intended use

The equipment under test (EUT) is a signal quality test and development board,indented to be used at laboratory or test and measurement areas. These areasare used for analysis, testing and servicing and where equipment is operated bytrained personnel (EN 61326-1, 3.9).

Operating site

Only use the product indoors, and keep it dry. The product has no casing and issensitive to moisture and humidity.

The product is suitable for pollution degree 2 environments where nonconductivecontamination can occur. For more information on environmental conditions suchas ambient temperature, see the specifications.

Safety instructions

Connect only USB interfaces to the boards.

Hot surface. The load board gets hot during testing. Do not touch. Risk ofskin burns. Risk of fire.

Electromagnetic emissions

The EUT is considered as a test probe, EN 61326-2-1, clause 5.2.4.101, note 1.Therefore normal operation may increase emissions and/or reduce immunity incertain applications.

Operation in type 3 (controlled) electromagnetic environments EN 61326-1, table3 is recommended.

The EUT is an EN 55011 class A equipment. Class A equipment is intended foruse in an industrial environment. There may be potential difficulties in ensuring

Page 4: R&S RTO/RTP-ZF1 USB Compliance Test Fixture · 2019-10-13 · R&S RTP, or R&S RTO oscilloscope with 4 channels and at least 2 GHz band-width. For full speed and low speed compliance

Product DescriptionR&S®RT-ZF1

4Manual 1317.4326.02 07

electromagnetic compatibility in other environments due to conducted as well asradiated disturbances.

ESD and EMI impact

The product is sensitive to electrostatic discharge (ESD) because of open mod-ules. Protect the work area against electrostatic discharge to avoid damage toelectronic components. Always work at a static-approved workstation.

Electromagnetic interference (EMI) can affect the measurement results. To avoidany impact, use only USB cables shorter 3 m.

2 Product DescriptionThe R&S RT‑ZF1 USB 2.0 compliance test fixture set is a product for automatictesting of USB 2.0 compliance (high-speed) as well as USB 1.1 (full-speed) andUSB 1.0 (low-speed). It is used in combination with the R&S RTO/R&S RTP oscil-loscopes, with the R&S RTO/R&S RTP-K21 USB 2.0 compliance test option(1317.4103.02)/(1337.8685.02) and the R&S ScopeSuite software.

For data, see the "R&S RT-ZFxx Oscilloscope Test Fixtures - Specifications" atwww.rohde-schwarz.com/brochure-datasheet/rto.

2.1 Deliveries

The R&S RT‑ZF1 comprises two test boards and accessories: Load board (1317.5300.02) Signal quality board (1317.5200.02) Accessories, see table Table 2-1 Carrying case Manual

Deliveries

Page 5: R&S RTO/RTP-ZF1 USB Compliance Test Fixture · 2019-10-13 · R&S RTP, or R&S RTO oscilloscope with 4 channels and at least 2 GHz band-width. For full speed and low speed compliance

Product DescriptionR&S®RT-ZF1

5Manual 1317.4326.02 07

Table 2-1: Supplied accessories

Item Quantity Order number

USB cable type A to type B, length 20 cm 2 3589.2124.00

USB cable type A to type B, length 1.3 m 2 0041.9177.00

USB Adapter, type A to mini 1 3589.2147.00

USB adapter, type A to micro-B 1 3589.2130.00

SMA cable, length 1 m, to connect the signal generator 2 1142.5889.00

2.2 Oscilloscope Connections

The following oscilloscope configuration is suitable for high-speed, full and lowspeed tests. For most tests, you can use either a differential probe or two single-ended active probes. The signal quality board is designed for comfortable con-nection of both probe types.

GNDD-

D- GND

D+ GNDGNDD+

Single-ended probesDifferential probe

Figure 2-1: Connectors for differential and single-ende probes

CH1 Single-ended probe connected to D+ (RT-ZS30)

CH2 Differential probe connceted to D+ and D- (RT-ZD30)

CH3 Single-ended probe connected to D- (RT-ZS30)

CH4 Inrush measurements

The test-specific connections are explained in the R&S ScopeSuite's test wizard.

2.3 Signal Quality Board

The signal quality board has several labeled sections designed for specific signalquality testing. The connectors and their purpose are shown on Figure 2-2.

Signal Quality Board

Page 6: R&S RTO/RTP-ZF1 USB Compliance Test Fixture · 2019-10-13 · R&S RTP, or R&S RTO oscilloscope with 4 channels and at least 2 GHz band-width. For full speed and low speed compliance

Product DescriptionR&S®RT-ZF1

6Manual 1317.4326.02 07

InrushX1 X2

TriggerX3 X4

X5 X6Back Voltage Host Signal Quality

DisconnectX7 X8

Receiver SensitivityX9 X10

Device SQX11 X12

Device Initialization

Power

US

B 2

.0 S

igna

lQ

ualit

y B

oard

R S

Test Init

56 Ohm 182

GNDD-

D- GND

D+ GNDGNDD+ BA

B

B

A

A

A

A

A

B

B

B

B

Init Test

Device on off

Device on off

GNDD-

GNDD+

GNDD-

GNDD+

D- GND

D+ GND

D- GND

D+ GND

GNDD-

GNDD+

GND

GND

D-

D+D-

D+

VBus

GNDD-

D- GND

D+ GNDGNDD+

VCC GND

GNDD-

D- GND

D+ GNDGNDD+

J1

D+

D-Init

Test

Init

Test

int

ext

X13

High-speed tests Device Hub Host- Signal quality x upstream - Packet parameters x upstream x- Chirp timing x upstream- Suspend/resume/ x upstream reset timing- Test J/K, SE0_NAK x upstream- Repeater up-/downstream

High-speed tests Hub Host- Signal quality downstream x - Chirp timing x- Suspend/resume/reset x - Test J/K, SE0_NAK downstream x- Repeater up-/downstream- Jitter downstream

High-speed tests Hub Host- Disconnect detect x x

High-speed tests Device Hub- Receiver sensitivity x upstream

Low and full speed tests: Device

Low and full speed tests: Hub

Low and full speed tests: Device, Hub

Figure 2-2: Signal quality board

Signal Quality Board

Page 7: R&S RTO/RTP-ZF1 USB Compliance Test Fixture · 2019-10-13 · R&S RTP, or R&S RTO oscilloscope with 4 channels and at least 2 GHz band-width. For full speed and low speed compliance

Product DescriptionR&S®RT-ZF1

7Manual 1317.4326.02 07

Device Initialization switch

The device initialization switch at the bottom of the board is relevant for devicehigh speed signal quality and device high speed receiver sensitivity tests. Thecurrent switch position - init or test - is indicated by LEDs in the relevant test sec-tions.

Power jumper

An external power supply is only required for testing DUTs that need more than420 mA supply current. For tests using additional power supply, set the jumper inthe "Power" section to "ext".

For all devices that need less than 420 mA supply current, the VBUS power fromthe host is sufficient, and the jumper position is "int".

J1 jumper

The J1 jumper switches the inrush current measurement between current mea-surement and voltage measurement. It is located in the "Inrush" section, theupper section of the board.

J1

Upper position: A measuring resistance of 0.1 Ω is active.You can measure the voltage using a differential probe and calculate the cur-rent consumption.

J1

Lower position: The measuring resistance is shorted-out. To measure the cur-rent consumption, you need a current probe.

SMA connectors

To perform hi-speed device and hub receiver sensitivity tests, a waveform gener-ator is required. The SMA connectors for the generator connection are located inthe "Receiver Sensitivity" section of the board.

2.4 Load Board

The load board has 12 USB type B connectors for load testing and a section forclocked droop testing.

Load Board

Page 8: R&S RTO/RTP-ZF1 USB Compliance Test Fixture · 2019-10-13 · R&S RTP, or R&S RTO oscilloscope with 4 channels and at least 2 GHz band-width. For full speed and low speed compliance

Product DescriptionR&S®RT-ZF1

8Manual 1317.4326.02 07

USB 2.0 Load BoardRS

Load 7

B

100 mA

500 mA

Load 8

B

100 mA

500 mA

Load 9

B

100 mA

500 mA

Load 10

B

100 mA

500 mA

Load 11

B

100 mA

500 mA

Load 12

B

100 mA

500 mA

Load 5

B

100 mA

500 mA

Load 6

B

100 mA

500 mA

Load 3

B

100 mA

500 mA

Load 4

B

100 mA

500 mA

Load 1

B

100 mA

500 mA

Load 2

B

100 mA

500 mA

Droop

B

Power

BGND

OSC

Warning Hot Surface

Figure 2-3: Load board

Load Board

Page 9: R&S RTO/RTP-ZF1 USB Compliance Test Fixture · 2019-10-13 · R&S RTP, or R&S RTO oscilloscope with 4 channels and at least 2 GHz band-width. For full speed and low speed compliance

Connecting the BoardR&S®RT-ZF1

9Manual 1317.4326.02 07

Risk of burning caused by hot load boardThe load board gets hot during testing. To avoid injuries: Do not touch the board when a test is running. After finishing the tests, set all switches to their middle position and wait

at least 5 min until the module cools down. Touch the board only at switches and edges. Do not touch the surface of

the board.

3 Connecting the BoardThe appropriate DUT and probe connection depends on the test case. TheR&S ScopeSuite software provides a step-by-step guide that shows the requiredsetup for each test case.

The test preparation and measurements of the test cases are described in the"R&S®RTO-K21, R&S®RTP-K21 USB 2.0 Compliance Tests, Test Procedures"manual.

4 Test EquipmentFor USB 2.0 compliance tests, the following test equipment is recommended:

R&S RTP, or R&S RTO oscilloscope with 4 channels and at least 2 GHz band-width. For full speed and low speed compliance tests, a 4-channel R&S RTOwith less than 2 GHz bandwidth is sufficient.

R&S RT-ZF1 USB 2.0 compliance test fixture set, which consists of the loadboard and the signal quality board.

Probes:– 2x single-ended active probes with at least 2 GHz bandwidth– 1x differential active probe with at least 2 GHz bandwidth

Page 10: R&S RTO/RTP-ZF1 USB Compliance Test Fixture · 2019-10-13 · R&S RTP, or R&S RTO oscilloscope with 4 channels and at least 2 GHz band-width. For full speed and low speed compliance

Test EquipmentR&S®RT-ZF1

10Manual 1317.4326.02 07

Tabor WX2182B / Tabor WX2182C arbitrary waveform generator for automaticreceiver sensitivity tests.For manual receiver sensitivity tests, any AWG with at least 1.44 Gsample/scan be used.

R&S ScopeSuite software, which can be installed on a computer or directly onthe R&S RTO/R&S RTP.

R&S RTO/R&S RTP-K21 USB 2.0 compliance test option (required option,installed on the R&S RTO/R&S RTP)

Make sure that you use the latest version of the USBHSET tool. To find down-loads, search for USBHSET on the following websites:– USB 3.0 host: www.usb.org/developers/tools/– USB 2.0 host: www.usb.org/developers/tools/usb20_tools/Regularly check the USB-IF website compliance.usb.org/index.asp?Update-File=Electrical&Format=Standard for USB-IF compliance updates.