Safe Change Housing
● Compact, modular design
● Fully enclosing bag systemfor safe filter change
● Suitable for both verticaldownflow and horizontalairflow
● Adjustable clampingmechanism for positiveairtight sealing
Application The RPT Safe Change Housing is areliable duct housing for the removalof Radioactive, Pathogenic and Toxiccontaminants. It can be suppliedwith a single or double stagefiltration system, consisting of asingle HEPA filter or a HEPA filterwith a prefilter. Typical areas ofapplication include the healthcare,pharmaceutical, microelectronic andnuclear industries as well asbiochemical laboratories. The unitcan be used for vertical downflow orhorizontal airflow.
SafetyThe RPT Housing is designed tofacilitate safe removal of contamina-ted filters and to minimize the risk ofhazardous particulate escaping intothe immediate environment. To thisend the housing is equipped with afully enclosed bag system into whichthe filter is placed for safe disposal.
Filter InstallationTo guarantee a truly leaktight systemthe HEPA filter is clamped against asealing frame with a maintenance-free positive locking mechanism,operated with a single lever; theprefilter is installed by pushing thesupport frame upwards.
Filter ReplacementFilter removal is done by opening theservice hatch, extending thepolyethylene bag and removing thecontaminated filter from the housinginto the bag, which is secured to thebag flange at the opening.
Space Saving DesignThe RPT housing is compact andmodular in design. To cater for highair volumes, modules may beinstalled side by side up to amaximum of 5 units in single ordouble row formation or,alternatively, one on top of the other.
Sturdy, Reliable Construction The standard unit is made of mildreinforced steel coated with epoxywhite paint. It can be operated at anoverpressure of up to 2500 Papositive and 3000 Pa negative. Theupper operating temperature limit is60˚C. Differential pressure measuringpoints are located in both theprefilter and mainfilter sections.
Options a) A flange with test groove for leak
testing of the gasket seal between main filter and housing
b) Coupling set consisting of frames and bolts for the installation of several adjacent units
c) Integrated prefilter sectiond) Stainless steel executione) Other (contact local AAF sales
office)
![Page 2: Rpt (af 2-741-in-1-0698)](https://reader037.vdocuments.us/reader037/viewer/2022100501/55a8dae61a28abb93e8b4712/html5/thumbnails/2.jpg)
RPT
AF-2-741-IN-1-0698 © 1998 AAF International
AAF has a policy of continuous product research and improvement and reserves the right to change design and specifications without notice
AAF-International B.V .P.O. Box 79281008 AC Amster damThe NetherlandsTel.: + 31 20 549 44 11 Fax: + 31 20 644 43 98
International AAF Offices:Vienna (A), Montreal (CDN), Dortmund (D),Vitoria (E), Paris (F), Cramlington (GB),Athens (GR), Milan (I), Riyadh (KSA), Mexico (Mex), Amsterdam (NL), Singapore,Istanbul (TR), Louisville, Ky (USA)
AAF Ag ents:Copenhagen (DK), Bangalore (IND)Oslo (N), Lisbon (P), Johannesburg (RSA), Dalsjöfors (S), Malmö (S), Helsinki (SF)
850
580
57.5 57.5
72 724X146 = 584
613
728
Ø 1
0
REC
OM
MEN
DED
FOR
SER
VIC
E57
.5
724X
146
= 58
4
613
728
72
57.5
135
1000
Total air flow capacity m3/s Filters
Size BioCel I / BioPak AstroCel I / AstroPak AstroCel I High Capacity 610 x 610 mm
at 125 Pa at 250 Pa at 125 Pa at 250 Pa at 125 Pa at 250 Pa Number
11 0.56 1.11 0.28 0.56 0.36 0.72 121 1.11 2.22 0.56 1.11 0.72 1.44 231 1.67 3.33 0.83 1.67 1.08 2.17 341 2.22 4.44 1.11 2.22 1.44 2.89 451 2.78 5.56 1.39 2.78 1.81 3.61 512 1.11 2.22 0.56 1.11 0.72 1.44 222 2.22 4.44 1.11 2.22 1.44 2.89 432 3.33 6.67 1.67 3.33 2.17 4.33 642 4.44 8.89 2.22 4.44 2.89 5.78 852 5.56 11.11 2.78 5.56 3.61 7.22 10
Style Code:
RPT-XX-X-X-X-X
Size: (see tabel)XX First digit: number adjecent filterhousings
Second digit: single(1) or double (2) rowX Prefilter / No prefilter (P or N)X Number of mainfilters in air flow directionX DIN test flange / No DIN test flange (D or N)*X Coupling set / No coupling set (C or N)
Example:
RPT-32-N-2-D-C
Size: 32 Three adjecent filterhousings
Double rowN No prefilter2 Two mainfilters in air flow directionD DIN test flange includedC Coupling set included