rpft exam questions

5
Pass (RPFT) Registry Examination for Advanced Pulmonary Function Technologists exam in just 24 HOURS! 100% REAL EXAM QUESTIONS ANSWERS (RPFT) Registry Examination for Advanced Pulmonary Function Technologists Buy Complete Questions Answers File from http://www.exams4sure.com/NBRC/RPFT-practice-exam- dumps.html 100% Exam Passing Guarantee & Money Back Assurance Sample Questions

Upload: examure4

Post on 14-Feb-2017

368 views

Category:

Education


0 download

TRANSCRIPT

Pass (RPFT) Registry Examination for Advanced Pulmonary

Function Technologists exam in just 24 HOURS!

100% REAL EXAM QUESTIONS ANSWERS (RPFT) Registry Examination for Advanced Pulmonary

Function Technologists

Buy Complete Questions Answers File from

http://www.exams4sure.com/NBRC/RPFT-practice-exam-

dumps.html

100% Exam Passing Guarantee & Money Back Assurance

Sample Questions

Question No 1:

Which of the following is the most reliable method to estimate the effectiveness of standard

procedures to minimize the risk of cross-contamination during spirometry testing in a

pulmonary function laboratory?

A. Count the number of disposable mouthpieces used for 1 week.

B. Observe the handwashing behavior of each technologist.

C. Ask patients tested about laboratory hygiene.

D. Ask technologists if they wash their hands before each test

Answer: B

Question No 2:

While performing duplicate blood gas analyses, a pulmonary function technologist notes that

the second instrument gives consistently higher values forPaCO2and PaO2. Which of the

following is the most probable cause of higher readings from the second instrument?

A. The sample chamber temperature is greater than 37° C

B. An excessive delay occurred between running the two samples

C. The PO2and PCO2electrodemembranes have protein build-up

D. The sample chamber has a bacterial contaminate

Answer: A

Question No 3:

Which of the following problems may be identified by using an isothermal lung analog to

perform quality control on a body plethysmograph?

1. 1.Improperly calibrated mouth pressure transducer

2. 2.Obstructed or perforated pneumotachometer

3. 3.Increase in mechanical resistance

4. 4.Malfunctioning box pressure transducer

A. 3 and 4 only

B. 2 and 3 only

C. 1 and 4 only

D. 1 and 2 only

Answer: C

Question No 4:

An isothermal lung analog has the following specifications:

5-L glass bottle

2000 g of steel wool

Density of steel wool 5 g/cm3

Volume of connectors and bulb 100 mi-Repeated FRC measurements in the plethysmograph

result in a volume of 5.5 L. Which of the following should a pulmonary function technologist

do?

A. Remove 500 g ofsteel wool from the lung analog

B. Take the plethysmograph out of service

C. Recalculate the BTPS correction

D. Begin a biologic control program

Answer: D

Question No 5:

A pulmonary function technologist is reviewing an asthma action plan. The patient takes a

low-dose inhaled corticosteroid and a long-acting beta2-agonist twice daily. The patient's

personal best peak flow is 600 L/min. Which of the following instructions should be given to

the patient when the peak flow drops to 500 L/min?

A. Add montelukast (Singular).

B. Continue the current regimen.

C. Go to the emergency department.

D. Double the steroid dose.

Answer: A

Question No 6:

A treadmill belt stops for a fraction of a second each time the patient takes a step. A

pulmonary function technologist should

A. Instruct the patient to use the hand rails.

B. Tighten the belt.

C. Increase the speed of the belt.

D. Decrease the treadmill grade.

Answer: B

Question No 7:

Prior to an exercise study, a pulmonary function technologist finds that the patient's RER is

1.13. Which of the following best explains this finding?

A. Carbohydrate metabolism

B. Protein metabolism

C. Hypoventilation

D. Hyperventilation

Answer: D

Question No 8:

A 6-year-old child has a history of repeated episodes of wheezing and shortness of breath. A

pulmonary function technologist has difficulty obtaining repeatable spirometry results.

Which of the following tests should be performed next?

A. MVV

B. DLco

C. SGaw

D. SpO2

Answer: A

Question No 9:

A pulmonary function technologist is performing an exercise (stress) test on a patient with

severe COPD. As the test progresses, the patient shows signs of increasing dyspnea.

Measurements of inspiratory capacity decreased from 2.0 L to 1.5 L. Which of the following

most likely occurred?

A. Dynamic hyperinflation

B. Disconnected gas sampling line

C. Drift in the flow transducer

D. Acute decrease in FRC

Answer: D

Question No 10:

During exercise, a subject's oxygen consumption increases out of proportion to his cardiac

output. This is due to an increase in

A. Anaerobic metabolism

B. Alveolar ventilation

C. Coronary blood flow

D. Oxygen extraction.

Answer: C

Buy Complete Questions Answers File from

PDF Version + Test Engine Software Version

90 Days Free Updates Service

Valid for All Countries

http://www.exams4sure.com/NBRC/RPFT-practice-exam-

dumps.html