Page 1: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

ROYAL GOVERNMENT OF BHUTANICP BUMPAGANG PROJECT

CHUKHA BHUTAN

ARCHITECTURAL DRAWINGS&

WATER SUPPLY & SEWERAGE SYSTEM

Page 2: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

TW 1855+1.5

1855+1

1855

1855 1855

STORM WATER LINE

VOLLEYBALL COURT

PAVED PARKING

PAVED PARKING

PAVED PARKING

PAVED PARKING

GATE

ASPHALTED ROAD

IMMG QUARTER

POLICE QUARTERPOLICE QUARTER

1855

1855

UP

BE

DR

OO

M 1

BE

DR

OO

M 2

KIT

CH

EN

LIV

IN

G R

OO

M

TO

ILE

T

D1

D1

D1

D1

D D

D2 D2

D2 D2

W W

W W

RW

RW RW

RW

DW DW

V1 V1

V V

UP

BE

DR

OO

M 1

BE

DR

OO

M 2

KIT

CH

EN

LIV

IN

G R

OO

M

TO

ILE

T

D1

D1

D1

D1

D D

D2 D2

D2 D2

W W

W W

RW

RW RW

RW

DW DW

V1 V1

V V

bedroom

living room

kitchen

powder room

closet

wash basin

shower

D D

D2 D2

D2D2

D D

W

W

W

WW

W

WW

WW1 W1

V1

V1

V1

V1

V1

V1

V1

V1

W

OFFICER QUARTER

W

1855

1855

1855

1855

TW 1855+3

TW 1855+4

TW 1855+4

TW 1855+3

TW 1855+3

TW 1855+2

TW 1855+.5

RW1

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measurements shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH-01

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction elements not designed by

us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

1:400

PROPOSED STRUCTURE: DRAWING TITLE:SITE PLAN

AutoCAD SHX Text
1865
AutoCAD SHX Text
1865
AutoCAD SHX Text
1860
AutoCAD SHX Text
1845
AutoCAD SHX Text
1840
AutoCAD SHX Text
1835
Page 3: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

3x40 X 60 M.S RECTANGULARHOLLOW SECTION

80mm THK. PCC SILL

3x40 X 60 M.S RECTANGULARHOLLOW SECTION

3mm THK. MS PLATE HORZINGWELDED TO THE MS FRAME

PLASTER PEM & DUNG

RCC BOH

PLASTER ZANGSHING

15 mm THK.CEMENT PLASTER (1:4)

250 MM THK. EXTERNALBRICK WALL

6mm CLEAR GLASS

3MM M.S PLATE TSEGAY

A A'

PLASTER ZANGSHING

RCC BOH

PLASTER PEM & DUNG

3mm THK. MS PLATE HORZINGWELDED TO THE MS FRAME

3x40 X 60 M.S RECTANGULARHOLLOW SECTION VERTICAL

FRAME

3x40 X 60 M.S RECTANGULARHOLLOW SECTION BOTTOM

FRAME

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measureme1:20 shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/W-09

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction eleme1:20 not designed

by us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

1:20

PROPOSED STRUCTURE: DRAWING TITLE:OFFICER'S QUARTER WINDOW V1 DETAILS

AutoCAD SHX Text
JINDAL AL. INTERLOCK GRADE D NO. 8611
AutoCAD SHX Text
PLAN AA' (v)
AutoCAD SHX Text
SECTION XX' (v)
AutoCAD SHX Text
JINDAL AL. SIDE SHUTTER FRAME GRADE D NO. 8610
AutoCAD SHX Text
x'
AutoCAD SHX Text
x
AutoCAD SHX Text
ELEVATION(v)
tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 4: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

3x40 X 60 M.S RECTANGULARHOLLOW SECTION

80mm THK. PCC SILL

3x40 X 60 M.S RECTANGULARHOLLOW SECTION

3mm THK. MS PLATE HORZINGWELDED TO THE MS FRAME

PLASTER PEM & DUNG

RCC BOH

PLASTER ZANGSHING

15 mm THK.CEMENT PLASTER (1:4)

250 MM THK. EXTERNALBRICK WALL

3MM M.S PLATE TSEGAY

PLASTER ZANGSHING

RCC BOH

PLASTER PEM & DUNG

3mm THK. MS PLATE HORZINGWELDED TO THE MS FRAME

A A'

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measureme1:20 shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/W-10

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction eleme1:20 not designed

by us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

1:20

PROPOSED STRUCTURE: DRAWING TITLE:OFFICER'S QUARTER WINDOW V DETAILS

AutoCAD SHX Text
PLAN AA' (V1)
AutoCAD SHX Text
SEC XX'(V1)
AutoCAD SHX Text
x'
AutoCAD SHX Text
x
AutoCAD SHX Text
ELEVATION(V1)
tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 5: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

6mm CLEAR GLASS

PLASTER ZANGSHING

RCC BOH

PLASTER PEM & DUNG

3x40 X 60 M.S RECTANGULARHOLLOW SECTION

3x40 X 60 M.S RECTANGULARHOLLOW SECTION VERTICAL

FRAME

PLASTER PEM & DUNG

RCC BOH

PLASTER ZANGSHING

A'A

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measureme1:20 shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/W-08

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction eleme1:20 not designed

by us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

1:20

PROPOSED STRUCTURE: DRAWING TITLE:OFFICER'S QUARTER WINDOW DW DETAILS

AutoCAD SHX Text
SECTION XX' (DW)
AutoCAD SHX Text
250mm thk BRICK WALL
AutoCAD SHX Text
JINDAL AL. SIDE SHUTTER FRAME GRADE D NO. 8610
AutoCAD SHX Text
PLAN AA' (DW)
AutoCAD SHX Text
JINDAL AL. INTERLOCK GRADE D NO. 8611
AutoCAD SHX Text
ELEVATION(DW)
AutoCAD SHX Text
x
AutoCAD SHX Text
x'
tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 6: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

3x40 X 60 M.S RECTANGULARHOLLOW SECTION BOTTOM

FRAME

3x40 X 60 M.S RECTANGULARHOLLOW SECTION VERTICAL

FRAME

3mm THK. MS PLATE HORZINGWELDED TO THE MS FRAME

PLASTER PEM & DUNG

RCC BOH

PLASTER ZANGSHING

A'A

3MM M.S PLATE TSEGAY

6mm CLEAR GLASS

250 MM THK. EXTERNALBRICK WALL

15 mm THK.CEMENT PLASTER (1:4)

PLASTER ZANGSHING

RCC BOH

PLASTER PEM & DUNG

3mm THK. MS PLATE HORZINGWELDED TO THE MS FRAME

3x40 X 60 M.S RECTANGULARHOLLOW SECTION

80mm THK. PCC SILL

3x40 X 60 M.S RECTANGULARHOLLOW SECTION

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measureme1:20 shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/W-07

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction eleme1:20 not designed

by us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

1:20

PROPOSED STRUCTURE: DRAWING TITLE:OFFICER'S QUARTER WINDOW W2 DETAILS

AutoCAD SHX Text
ELEVATION(W2)
AutoCAD SHX Text
x
AutoCAD SHX Text
x'
AutoCAD SHX Text
250mm thk BRICK WALL
AutoCAD SHX Text
JINDAL AL. SIDE SHUTTER FRAME GRADE D NO. 8610
AutoCAD SHX Text
SECTION XX' (W2)
AutoCAD SHX Text
PLAN AA' (W2)
AutoCAD SHX Text
JINDAL AL. INTERLOCK GRADE D NO. 8611
tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 7: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

A'A

3MM M.S PLATE TSEGAY

6mm CLEAR GLASS

250 MM THK. EXTERNALBRICK WALL

15 mm THK.CEMENT PLASTER (1:4)

PLASTER ZANGSHING

RCC BOH

PLASTER PEM & DUNG

3mm THK. MS PLATE HORZINGWELDED TO THE MS FRAME

3x40 X 60 M.S RECTANGULARHOLLOW SECTION

80mm THK. PCC SILL

3x40 X 60 M.S RECTANGULARHOLLOW SECTION

3x40 X 60 M.S RECTANGULARHOLLOW SECTION VERTICAL

FRAME

3mm THK. MS PLATE HORZINGWELDED TO THE MS FRAME

PLASTER PEM & DUNG

RCC BOH

PLASTER ZANGSHING

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measureme1:20 shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/W-06

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction eleme1:20 not designed

by us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

1:20

PROPOSED STRUCTURE: DRAWING TITLE:OFFICER'S QUARTER WINDOW W1 DETAILS

AutoCAD SHX Text
ELEVATION(W1)
AutoCAD SHX Text
x
AutoCAD SHX Text
x'
AutoCAD SHX Text
250mm thk BRICK WALL
AutoCAD SHX Text
SECTION XX' (W1)
AutoCAD SHX Text
PLAN AA' (W1)
AutoCAD SHX Text
RCC COLUMN
AutoCAD SHX Text
250mm thk BRICK WALL
tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 8: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

3x40 X 60 M.S RECTANGULARHOLLOW SECTION BOTTOM

FRAME

3x40 X 60 M.S RECTANGULARHOLLOW SECTION VERTICAL

FRAME

3mm THK. MS PLATE HORZINGWELDED TO THE MS FRAME

PLASTER PEM & DUNG

RCC BOH

PLASTER ZANGSHING

A'A

3MM M.S PLATE TSEGAY

6mm CLEAR GLASS

250 MM THK. EXTERNALBRICK WALL

15 mm THK.CEMENT PLASTER (1:4)

PLASTER ZANGSHING

RCC BOH

PLASTER PEM & DUNG

3mm THK. MS PLATE HORZINGWELDED TO THE MS FRAME

3x40 X 60 M.S RECTANGULARHOLLOW SECTION

80mm THK. PCC SILL

3x40 X 60 M.S RECTANGULARHOLLOW SECTION

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measureme1:20 shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/W-05

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction eleme1:20 not designed

by us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

1:20

PROPOSED STRUCTURE: DRAWING TITLE:OFFICER'S QUARTER WINDOW W DETAILS

AutoCAD SHX Text
ELEVATION(W)
AutoCAD SHX Text
x
AutoCAD SHX Text
x'
AutoCAD SHX Text
250mm thk BRICK WALL
AutoCAD SHX Text
JINDAL AL. SIDE SHUTTER FRAME GRADE D NO. 8610
AutoCAD SHX Text
SECTION XX' (W)
AutoCAD SHX Text
PLAN AA' (W)
AutoCAD SHX Text
JINDAL AL. INTERLOCK GRADE D NO. 8611
tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 9: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

3x40 X 60 M.S RECTANGULARHOLLOW SECTION BOTTOM

FRAME

3x40 X 60 M.S RECTANGULARHOLLOW SECTION VERTICAL

FRAME

3mm THK. MS PLATE HORZINGWELDED TO THE MS FRAME

A'A

3MM M.S PLATE TSEGAY

6mm CLEAR GLASS

250 MM THK. EXTERNALBRICK WALL

15 mm THK.CEMENT PLASTER (1:4)

3mm THK. MS PLATE HORZINGWELDED TO THE MS FRAME

3x40 X 60 M.S RECTANGULARHOLLOW SECTION

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measureme1:20 shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/W-04

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction eleme1:20 not designed

by us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

1:20

PROPOSED STRUCTURE: DRAWING TITLE:OFFICER'S QUARTER WINDOW RW2 DETAILS

AutoCAD SHX Text
ELEVATION(RW2)
AutoCAD SHX Text
x
AutoCAD SHX Text
x'
AutoCAD SHX Text
250mm thk BRICK WALL
AutoCAD SHX Text
JINDAL AL. SIDE SHUTTER FRAME GRADE D NO. 8610
AutoCAD SHX Text
SECTION XX' (RW2)
AutoCAD SHX Text
PLAN AA' (RW2)
AutoCAD SHX Text
JINDAL AL. INTERLOCK GRADE D NO. 8611
tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 10: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

A'A

3x40 X 60 M.S RECTANGULARHOLLOW SECTION VERTICAL

FRAME

3mm THK. MS PLATE HORZINGWELDED TO THE MS FRAME

PLASTER PEM & DUNG

3MM M.S PLATE TSEGAY

6mm CLEAR GLASS

250 MM THK. EXTERNALBRICK WALL

15 mm THK.CEMENT PLASTER (1:4)

3mm THK. MS PLATE HORZINGWELDED TO THE MS FRAME

3x40 X 60 M.S RECTANGULARHOLLOW SECTION

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measureme1:20 shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/W-03

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction eleme1:20 not designed

by us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

1:20

PROPOSED STRUCTURE: DRAWING TITLE:OFFICER'S QUARTER WINDOW RW1 DETAILS

AutoCAD SHX Text
ELEVATION(RW1)
AutoCAD SHX Text
x
AutoCAD SHX Text
x'
AutoCAD SHX Text
250mm thk BRICK WALL
AutoCAD SHX Text
PLAN AA' (RW1)
AutoCAD SHX Text
RCC COLUMN
AutoCAD SHX Text
250mm thk BRICK WALL
AutoCAD SHX Text
SECTION XX' (RW1)
tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 11: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

3x40 X 60 M.S RECTANGULARHOLLOW SECTION BOTTOM

FRAME

3x40 X 60 M.S RECTANGULARHOLLOW SECTION VERTICAL

FRAME

3mm THK. MS PLATE HORZINGWELDED TO THE MS FRAME

A'A

3MM M.S PLATE TSEGAY

6mm CLEAR GLASS

250 MM THK. EXTERNALBRICK WALL

15 mm THK.CEMENT PLASTER (1:4)

3mm THK. MS PLATE HORZINGWELDED TO THE MS FRAME

3x40 X 60 M.S RECTANGULARHOLLOW SECTION

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measureme1:20 shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/W-02

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction eleme1:20 not designed

by us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

1:20

PROPOSED STRUCTURE: DRAWING TITLE:OFFICER'S QUARTER WINDOW RW DETAILS

AutoCAD SHX Text
ELEVATION(RW)
AutoCAD SHX Text
x
AutoCAD SHX Text
x'
AutoCAD SHX Text
250mm thk BRICK WALL
AutoCAD SHX Text
JINDAL AL. SIDE SHUTTER FRAME GRADE D NO. 8610
AutoCAD SHX Text
SECTION XX' (RW)
AutoCAD SHX Text
PLAN AA' (RW)
AutoCAD SHX Text
JINDAL AL. INTERLOCK GRADE D NO. 8611
tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 12: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

08

44

18

TOTAL

OFFICER

00

06

04

IMMIG.

04

10

06

POLICE=2X

02=04021002500DW

14=2845016502500W

02.

ALUMINUM WINDOWS

WINDOW SCHEDULE

REMARKS

04=0875017352500RW01.

NO.CILL

HEIGHTWIDTHDIMENSIONS(MM)

ITEMSL NO.

10020004=08100011001100V

04.

28041604=08100011001100V1

05.

07.

02000200=0045016502500W1

02000200=0075017352500RW1

08.

09.

03. 02020000=0075017352100RW2

06. 04020200=0045016502100W2

ALUMINUM WINDOWS

ALUMINUM WINDOWS

ALUMINUM WINDOWS

ALUMINUM WINDOWS

ALUMINUM WINDOWS

ALUMINUM WINDOWS

ALUMINUM WINDOWS

ALUMINUM WINDOWS

02020000=00002375600L109. PVC LOUVRES

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measureme1:20 shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/W-01

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction eleme1:20 not designed

by us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

NTS

PROPOSED STRUCTURE: DRAWING TITLE:OFFICER'S QUARTER WINDOW SCHEDULES

tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 13: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

ROYAL GOVERNMENT OF BHUTANICP BUMPAGANG PROJECT

CHUKHA BHUTAN

ARCHITECTURAL DRAWINGS

WINDOW DETAILS

Page 14: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

FFL

75x100 Wooden Door Frame

40x100 Shutter Frame

30 MM Thk. Wooden Panel

SECTION BB' (D3)

INSIDEOUTSIDE

40x100 Lock Rail

40x120 Bottom Rail

30 MM Thk. Wooden Panel

75x100 Timber Frame

40x100 Timber Shutter Frame

30mm Thk Wooden Panel

ELEVATION (D3)

SECTION AA' (D3)

RCC Lintel

OUTSIDE

INSIDE

D3

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measurements shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/D-05

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction elements not designed by

us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

1:20

PROPOSED STRUCTURE: DRAWING TITLE:DOOR D3 DETAILS

AutoCAD SHX Text
B
AutoCAD SHX Text
B'
AutoCAD SHX Text
A
AutoCAD SHX Text
A'
tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 15: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

FFL

75x100 Wooden Door Frame

40x100 Shutter Frame

30 MM Thk. Wooden Panel

SECTION BB' (D2)

INSIDEOUTSIDE

40x100 Lock Rail

40x120 Bottom Rail

30 MM Thk. Wooden Panel

75x100 Timber Frame

40x100 Timber Shutter Frame

30mm Thk Wooden Panel

ELEVATION (D2)

SECTION AA' (D2)

RCC Lintel

OUTSIDE

INSIDE

D2

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measurements shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/D-04

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction elements not designed by

us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

1:20

PROPOSED STRUCTURE: DRAWING TITLE:DOOR D2 DETAILS

AutoCAD SHX Text
B
AutoCAD SHX Text
B'
AutoCAD SHX Text
A
AutoCAD SHX Text
A'
tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 16: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

FFL

75x100 Wooden Door Frame

40x100 Shutter Frame

30 MM Thk. Wooden Panel

SECTION BB' (D1)

INSIDEOUTSIDE

40x100 Lock Rail

40x120 Bottom Rail

30 MM Thk. Wooden Panel

75x100 Timber Frame

40x100 Timber Shutter Frame

30mm Thk Wooden Panel

ELEVATION (D1)

SECTION AA' (D1)

RCC Lintel

OUTSIDE

INSIDE

D1

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measurements shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/D-03

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction elements not designed by

us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

1:20

PROPOSED STRUCTURE: DRAWING TITLE:DOOR D1 DETAILS

AutoCAD SHX Text
B
AutoCAD SHX Text
B'
AutoCAD SHX Text
A
AutoCAD SHX Text
A'
tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 17: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

FFL

75x100 Wooden Door Frame

40x100 Shutter Frame

30 MM Thk. Wooden Panel

SECTION BB' (D1)

INSIDEOUTSIDE

40x100 Lock Rail

40x120 Bottom Rail

30 MM Thk. Wooden Panel

75x100 Timber Frame

40x100 Timber Shutter Frame

30mm Thk Wooden Panel

ELEVATION (D1)

SECTION AA' (D1)

RCC Lintel

OUTSIDE

INSIDE

D

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measurements shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/D-02

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction elements not designed by

us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

1:20

PROPOSED STRUCTURE: DRAWING TITLE:DOOR D DETAILS

AutoCAD SHX Text
B
AutoCAD SHX Text
B'
AutoCAD SHX Text
A
AutoCAD SHX Text
A'
tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 18: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

SL NO. ITEM

DIMENSIONS(MM)

WIDTH HEIGHT

CILL NO.

01.

02.

D 1000 2100 0 04=08

REMARKS

DOOR SCHEDULE

PANELLED DOOR

PANELLED DOOR

03.

D1 900 2100 0 08=16

PANELLED DOORD2 800 2100 0 08=16

POLICE=2X

08

00

08

IMMIG.

02

06

06

OFFICER

TOTAL

18

22

30

04.PANELLED DOOR

D3 750 2100 0 00=00 00 02 02

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measurements shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/D-01

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction elements not designed by

us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

NTS

PROPOSED STRUCTURE: DRAWING TITLE:DOOR SCHEDULES

tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 19: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

ROYAL GOVERNMENT OF BHUTANICP BUMPAGANG PROJECT

CHUKHA BHUTAN

ARCHITECTURAL DRAWINGS

DOOR DETAILS

Page 20: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

PLINTH PROTECTION DETAILS

scale 1:10

MS DRAIN COVER PLAN

scale 1:10

GROUND LVL

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measurements shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/MS-02

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction elements not designed by

us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

1:20

PROPOSED STRUCTURE: DRAWING TITLE:MISCELLANEOUS DETAILS-PLINTH PROTECTION & RAILINGS

AutoCAD SHX Text
75 mm thk pcc
AutoCAD SHX Text
40x40x3.49 ms angle
AutoCAD SHX Text
cement slurry
AutoCAD SHX Text
300 mm thk stone soling
AutoCAD SHX Text
earth
AutoCAD SHX Text
ms plate @ 30mm C/C
AutoCAD SHX Text
75 mm thk pcc
AutoCAD SHX Text
300 mm thk stone soling
AutoCAD SHX Text
40x40 ms angle
AutoCAD SHX Text
4.49 ms plate
AutoCAD SHX Text
cement slurry
AutoCAD SHX Text
cement slurry
AutoCAD SHX Text
PCC
AutoCAD SHX Text
65 MM DIA WOODEN HAND RAIL SCREWED TO ALIGNING STEEL PLATE
AutoCAD SHX Text
25X25 STEEL BULLUSTER
AutoCAD SHX Text
40 MM THK MARBLE FINISH
AutoCAD SHX Text
150 MM THK RCC SLAB
AutoCAD SHX Text
6 X45 STEEL ALIGNING PLATE
AutoCAD SHX Text
PCC INFILL
AutoCAD SHX Text
STEEL BULLUSTER BASE COVER
AutoCAD SHX Text
65X65 WOODEN HANDRAIL
AutoCAD SHX Text
6 MM THK M.S ALIGNING PLATE
AutoCAD SHX Text
SCREW
AutoCAD SHX Text
25X25 BULUSTRADE
AutoCAD SHX Text
BULUSTRADE BASE COVER
AutoCAD SHX Text
TERAZZO FF
AutoCAD SHX Text
P.C.C INFILL
tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 21: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

CEILING DETAILS

scale 1:20

TIMBER FLOORING SECTION

scale 1:20

TILES FLOORING SECTION

scale 1:20

TIMBER & TILES FLOORING JUNCTION SECTION

scale 1:20

ROYAL GOVERNMENT OF BHUTANMINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICESENGINEERING SERVICES DIVISION

ARCHITECTURE SECTIONP.O.BOX-129THIMPHU

DATEREV. DESIGNED & DRAWN BY: CHECKED BY: APPROVED BY:

Chief Engineer, ESD

DRAWING NO:

Tshering Norbu, Sr. Architect Executive Architect, ESD

NOTES:1. Drawings are not to be scaled of and measurements shown in drawings are to be

followed.2. Designer's responsibility shall remain limited to safe and sound structural design

by this drawings and shall not be remain responsible for:3. Safety of the construction worker/any personnel at works site during construction.4. Correctness/safety of any temporary structure, scaffolding, shuttering, centering

erected at site and any injury to any personnel arising out of any accident.

ARCH/MS-01

DATE:

PROJECT:

SCALE:

HOUSING COMPLEX FOR INTEGRATED CHECK POINT, BUMPAGANG5. Any Accident occurring due to construction elements not designed by

us.6. Accident occurring due to premature de shuttering, faulty/sunstandard

construction material or workmanship/faulty construction procedure.7. All structural concrete should be weigh batched, machine mixed &

mechanically vibrated.8. Any discrepancy in the drawings should be brought to the notice of

designer before construction.

20/07/2017

1:20

PROPOSED STRUCTURE: DRAWING TITLE:MISCELLANEOUS DETAILS - FLOOR & CEILING DETAILS

AutoCAD SHX Text
150x125 ceiling joist in timber
AutoCAD SHX Text
50x50 timber battens 450 c/c
AutoCAD SHX Text
rcc beam
AutoCAD SHX Text
6 mm plyboard
AutoCAD SHX Text
compacted earth
AutoCAD SHX Text
300 mm stone soling
AutoCAD SHX Text
100 mm thk 1:3:6 PCC
AutoCAD SHX Text
100 mm thk insulation
AutoCAD SHX Text
40 mm thk timber flooring in factory fabricated tounge & groove finished in french or Italian polish
AutoCAD SHX Text
100x75 mm timber floor jois @ 400 mm c-c
AutoCAD SHX Text
20 mm self tightening bolt
AutoCAD SHX Text
40x150 mm timber skirting
AutoCAD SHX Text
12 mm thk cement plaster
AutoCAD SHX Text
DPC/Moisture barrier
AutoCAD SHX Text
250mm thk Brickwall
AutoCAD SHX Text
wall putty-cement primier-white plastic washable paint finish
AutoCAD SHX Text
compacted earth
AutoCAD SHX Text
300 mm stone soling
AutoCAD SHX Text
DPC/Moisture barrier
AutoCAD SHX Text
100 mm thk 1:3:6 PCC
AutoCAD SHX Text
24 mm thk cement mortar + water proofing compound on wet areas
AutoCAD SHX Text
6 mm thk anti skit tiles
AutoCAD SHX Text
6x150 tile skirting
AutoCAD SHX Text
12 mm thk cement plaster
AutoCAD SHX Text
250mm thk Brickwall
AutoCAD SHX Text
wall putty-cement primier-white plastic washable paint finish
AutoCAD SHX Text
compacted earth
AutoCAD SHX Text
300 mm stone soling
AutoCAD SHX Text
100 mm thk PCC
AutoCAD SHX Text
100 mm thk insulation
AutoCAD SHX Text
40 mm thk timber flooring
AutoCAD SHX Text
DPC/Moisture barrier
AutoCAD SHX Text
4x40 mm ms strip at the junction
AutoCAD SHX Text
compacted earth
AutoCAD SHX Text
300 mm stone soling
AutoCAD SHX Text
DPC/Moisture barrier
AutoCAD SHX Text
100 mm thk PCC
AutoCAD SHX Text
24 mm thk cement mortar + water proofing compound on wet areas
AutoCAD SHX Text
6 mm thk anti skit tiles
tshering
Stamp
tshering
Stamp
tshering
Stamp
Page 22: ROYAL GOVERNMENT OF BHUTAN ICP BUMPAGANG · PDF fileicp bumpagang project chukha bhutan architectural drawings & water supply & sewerage system. tw 1855+1.5 1855+1 ... architecture

ROYAL GOVERNMENT OF BHUTANICP BUMPAGANG PROJECT

CHUKHA BHUTAN

ARCHITECTURAL DRAWINGS

MISCELLANEOUS DETAILS(FLOOR, CEILING, PLINTH PROTECTION & RAILING DETAILS)