rotem data solutions - haemoview diagnostics · rotem® data solutions data solutions - on time...
TRANSCRIPT
®
ROTEM data solutions
Data solutions - On time information.
Where it is needed.
All test results are available in numerical and graphical formats. transfer
to LIS/HIS systems or is possible. Real time transmission to a defined PC and
®
ROTEM
Secure Viewer
Perform measurements where it suits
Transfer TEMograms and numerical results in real time to the screen where it is needed
Complicated bleeding situations can appear intra and post operatively.
They can be life-threatening and always require immediate action.
A fast differential diagnosis is the basis of a targeted therapy.
® ®The ROTEM software allows remote transmission of the ROTEM
measurements.
®With the ROTEM Secure Viewer TEMograms and numerical results are
transmitted in real time from the site of the analysis directly into the
operating room.
Special features allow to activate or deactivate overlays and to take or
print screenshots.
System requirements for the :
®- Windows XP or higher.
- MS framenetwork 2.0 or higher.®
- Network structure allowing ROTEM connection.®
- Static IP address assigned to and entered into the ROTEM .
- Firewall configuration allowing network connection between the ®
ROTEM TCP-Port 9393 and the external viewer PC‘s.
® ROTEM Secure Viewer
®
ROTEM®
live(part of ROTEM connect )
® ®The ROTEM live ROTEM
therapy when bedside testing is not possible.
®It shows in real-time TEMograms and numerical results of ROTEM
measurements from the site of the analysis directly into the operating
room.
Precondition is a web-browser* on a PC or mobile device connected to ®
the same network as the ROTEM device.
®In the ROTEM live browser page measurements can be searched by
patient ID or sample ID.
®ROTEM live includes an independent user management. Through
individual adjustable passwords traceability can be ensured and
unauthorised access is prevented.
is a web-based tool to support targeted
*
Perform measurements where it is convenient
Transfer TEMograms and numerical results in real time to the browser where it is needed
®
ROTEM®
live(part of ROTEM connect )
®The ROTEM live ®
machine in the same network as the ROTEM devices and the devices
accessing the web interface.
The virtual machine requires the following properties:
- Virtual CPU (32 bit), PAE/NX enabled
- Virtual Network connection according to requirements of the network environment
- 512 MB of RAM- Virtual hard disk of 20GB- Virtual optical drive- Supported browsers:
- Firefox 17 or higher- Internet Explorer 9 or higher- Google Chrome 20 or higher- Safari 6 and 8
®The ROTEM live user management ensures traceability and prevents
unauthorised access.
®ROTEM live features two levels of log files.
The first level includes an overview of log-in and log-out, searched
patient/sample ID, displayed measurements and the download of pdf
screenshots.
The second level service log-files monitor changes of settings, the
creation, and modification of user accounts in the user management.
® is part of ROTEM connect. It is executed on a virtual
User management
Log files
®
ROTEM
Connectivity Kit
Contact
81829 Munich
© IT
2015_01
®With one interface the ROTEM Connectivity Kit connects up to 12
® ® ROTEM devices through the ROTEM Concentrator to the LIS / HIS.
Bidirectional data transfer sends measurement results to the LIS / HIS
and assigns patient data to a measurement.
®ROTEM Connectivity Kit features:
– Data transfer to LIS / HIS in DOS, XML, HL7 and ASTM protocols
– Patient data request (bidirectional connection)
– DHCP or static IP addresses
– Data transfer and patient data request from different servers
– Data transfer with or without TEMograms
– Transformation of incoming data into standard protocols HL7 or ASTM
(low or high level)
– Management of patient data requests
®The ROTEM Connectivity Kit is distributed by
Conworx Technology GmbH, Albert-Einstein-Str.14, 12489 Berlin,
Germany
www.conworx.com
! +49 30 92 10 11 0
Transfer measurement data to LIS / HIS