rom and rompak range - fluidcontrol...the rom range of actuators is now enhanced with the addition...
TRANSCRIPT
ROM and ROMpak Range
Quarter-turn Direct DriveElectric Actuators
Keeping the World Flowing
A4 US
US
A4
US
A4
A4 US
2
Keeping the World Flowing
RELIABILITY IN FLOW CONTROL
CRITICAL APPLICATIONS
RELIABLE OPERATION WHEN IT MATTERS
Assured reliability for critical applications and environments.
Whether used 24/7 or infrequently, Rotork products will operate reliably and efficiently when called upon.
LOW COST OF OWNERSHIP
Long-term reliability prolongs service life.
Rotork helps to reduce long term cost of ownership and provides greater efficiency to process and plant.
QUALITY-DRIVEN GLOBAL MANUFACTURING
Products designed with 60 years of industry and application knowledge.
Research and development across all our facilities ensures cutting edge products are available for every application.
CUSTOMER-FOCUSED SERVICE WORLDWIDE SUPPORT
Solving customer challenges and developing new solutions.
From initial enquiry through to product installation, long-term after-sales care and client support programmes.
ROM and ROMpak Range
A4US
US
A4
US A4
US
A4
Keeping the World Flowing 3
Section Page
CORPORATE SOCIAL RESPONSIBILITY
A responsible business leads to being the best business.
We are socially, ethically, environmentally responsible and committed to embedding CSR across all our processes and ways of working.
COMPREHENSIVE PRODUCT RANGE SERVING MULTIPLE INDUSTRIES
Improved efficiency, assured safety and environmental protection.
Rotork products and services are used in the Power, Oil & Gas, Water & Waste Water, HVAC, Marine, Mining, Food & Beverage, Pharmaceutical and Chemical industries around the world.
MARKET LEADER TECHNICAL INNOVATOR
The recognised market leader for 60 years.
Our customers have relied upon Rotork for innovative solutions to safely manage the flow of liquids, gases and powders.
GLOBAL PRESENCE LOCAL SERVICE
Global company with local support.
Manufacturing sites, offices and Centres of Excellence throughout the world provide unrivalled customer services and fast delivery.
Product Overview 4
Features of the ROM and ROMpak Range 5
Mechanical and Electrical Data 6
Circuit Diagram and Optional Extras 8
Dimensional Data 10
ROM and ROMpak Range
A4 US
US
A4
US
A4
A4 US
4 ROM and ROMpak Range
Product Overview
As one of the world’s leading manufacturers of actuation products, Rotork has built up an enviable reputation as the supplier of equipment which is both reliable and durable.
With over fifty years of experience of long term installation in all environments we have evolved a design of uncompromising reliability. With the addition of the ROM and ROMpak range, Rotork is complementing its offering of quarter-turn actuators with a simple and reliable solution for small valves.
Rotork ROM Actuator:
• Small
• Compact
• Lightweight
• Local position indication
• ISO flanges
• High speed variant
• Efficient yet simple gearing
• On-off duty
• Single-phase, three-phase and DC versions
• Quiet & reliable
• IP68
• Manual override
• Self-locking*
Rotork ROM with Electrical Control PAK Option (ROMpak)
• Local controls
• Phase rotation correction
• Network compatibility
• Analogue control and feedback available
* Applies only to ROM and ROMpak 2, 3, 4, 5 & 6 actuators
A4US
US
A4
US A4
US
A4
Keeping the World Flowing 5
The ROM and ROMpak actuators provide quiet and reliable operation for all kinds of small ball valves and butterfly valves*, as well as dampers and ventilation louvres. They provide a local indicator and manual override options together with a wide range of voltages.
Features:
Motor
• Standard duty cycle induction motor - S3. F insulation class for all ROM and ROMpak actuators
Position Indicator
• All models have continuous position indication on the actuator top cover
Manual Override
• Non-clutch design, the manual operation can be operated without any lever, clutch or brake upon power outage
• When the electric motor is operating, the manual override will not rotate except on ROMH-1 to ROMH-3, ROM-1 & ROM-A
Gear Train
• High alloy steel gear trains provide self-locking function to avoid valve back drive*
• ROM-1 and ROM-A designs incorporate an efficient spur gear train which can back drive in certain applications
• Gear trains are factory lubricated with a wide temperature rated lubricant
Mechanical Stops
• Externally adjustable mechanical stops are provided*
Working Conditions
• Ambient temperature: -30 to +70 ºC†
• Humidity: 30% to 95%
Various Options
• Anti-condensation heater
• Additional limit switches
• Conduit entries M20 x 1.5p
• Torque switches*
Certificates
• ISO 9001, CE, CSA, BV
The ROMpak
The ROM range of actuators is now enhanced with the addition of the ROMpak actuator. The ROMpak has a self contained control package with local controls, status indication relays, isolated control circuits and support for Rotork control options such as Folomatic, Pakscan and other bus systems.
• Small, compact & lightweight
• Manual override
• Externally adjustable mechanical stops*
• Local control unit (local/remote, on/off)
• Status relays
• Phase rotation correction
• IP68 (10m-100hr)
• 12/24 VDC, 110/220 VAC single-phase and 220/380/440 VAC three-phase*, 50 Hz and 60 Hz
• Position indication via local mechanical indicator and LED’s
• -30 to +70 ºC† operation
† Excluding 12/24 VDC.
Various Options:
• Bus communications including: PakscanTM, Profibus®, Modbus® and Foundation Fieldbus®.
• CPT & Folomatic
The ROMH
The ROM range of actuators now includes the ROMH actuator. The ROMH actuator has been designed for high-speed applications. This actuator is also available with the self-contained control package (ROMpakH). All features from the ROM and ROMpak are also available on the ROMH and ROMpakH.
• Small, compact, lightweight and high speed
• Speeds of 4.5 and 5.5 seconds per 90 degrees
• Manual override
• Bus communications including: Pakscan, Profibus, Modbus and Foundation Fieldbus
• Analogue congtrol and feedback
• DC and single-phase options
ROM ROMpak
Enclosure IP68Waterproof - Dustproof
IP68Waterproof - Dustproof
Material Aluminium Alloy Aluminium Alloyand plastic
Finish Dry powder coated Dry powder coated and wet spray
* Applies only to ROM and ROMpak 2, 3, 4, 5 & 6 actuators
ROM and ROMpak Range
† Excluding 12/24 VDC.
A4 US
US
A4
US
A4
A4 US
ROM and ROMpak Range6
Mechanical and Electrical Data
Mechanical Data
Model ROM Weight (kg)
ROMpak Weight (kg)
Manual override
Output Drive (mm)
TorqueNm/lbf.ft
Mounting base designation to ISO5211 imperial
ROM-1 2 4 Hexagonal Drive 14/11/9 35/26 F03/F05
ROM-A 2.8 4.7 Hexagonal Drive 17/14 50/37 F05/F07
ROM-2 10.9 13.1 Handwheel 22/17 90/67 F07
ROM-3 10.9 13.1 Handwheel 22/17 150/110 F07
ROM-4 25.1 27.1 Handwheel 36/35 400/295 F10
ROM-5 25.1 27.1 Handwheel 36/35 500/370 F10
ROM-6 25.1 27.1 Handwheel 36/35 650/480 F10
NOTE: Weight data based on single-phase 50Hz supply.
Three-Phase
Model No.
Torque (Nm)
Speed (sec/90°) 50 Hz 60 Hz
Motor Power (W)
220 V Current Run Lock
380 V CURRENT (A) Run Lock
440 V CURRENT (A) Run Lock
ROM-2 90 16 14 46 1.3 1.8 0.45 0.83 0.58 0.80
ROM-3 150 26 22 46 1.3 1.8 0.45 0.83 0.58 0.80
ROM-4 400 20 17 105 2.45 4.5 0.7 2 0.63 1.77
ROM-5 500 26 22 105 2.45 4.5 0.7 2 0.63 1.77
ROM-6 650 33 28 105 2.45 4.5 0.7 2 0.63 1.77
Electrical Performance Data
12V/24V*
Model No.
Torque (Nm)
Speed (sec/90°)
Motor Power (W)
12 VDC/VAC CURRENT (A) Run Lock
24 VDC/VAC CURRENT (A) Run Lock
ROM-1 35 20 4.2 1.2 2.2 0.6 1.2
ROM-A 50 30 4.2 1.2 2.2 0.6 1.2
ROM-2 90 17 43 2.5 20 1.1 11
ROM-3 150 28 43 3.2 20 1.5 11
ROM-4 400 23 92 11 42 5.5 21
ROM-5 500 30 92 11 42 5.5 21
ROM-6 650 38 92 11 42 5.5 21
*12/24 VAC not available for ROMpak.
Single-Phase
Model No.
Torque (Nm)
Speed (sec/90°) 50 Hz 60 Hz
Motor Power (W)
110 V CURRENT (A) Run Lock
220 V CURRENT (A) Run Lock
ROM-1 35 15 13 5 0.36 0.4 0.23 0.25
ROM-A 50 22 19 5 0.36 0.4 0.23 0.25
ROM-2 90 17 15 43 1.0 1.7 0.65 1.0
ROM-3 150 28 24 43 1.0 1.7 0.65 1.0
ROM-4 400 20 17 105 1.9 5.0 0.85 2.3
ROM-5 500 26 22 105 1.9 5.0 0.85 2.3
ROM-6 650 33 28 105 1.9 5.0 0.85 2.3
ROM and ROMpak
* Note: ROM-1, ROM-A, ROMpak-1, ROMpak-A, are not suitable for butterfly valves which may back drive
A4US
US
A4
US A4
US
A4
Keeping the World Flowing 7
Mechanical and Electrical Data
Operating Voltages:
ROM12
VDC24
VDC12
VAC24
VAC110 V/1
220 V/1
220 V/3
380 V/3
440 V/3
ROM-A
ROM-1
ROM-2,3
ROM-4,5&6
ROMpak12
VDC24
VDC12
VAC24
VAC110 V/1
220 V/1
220 V/3
380 V/3
440 V/3
ROMpak-A
ROMpak-1
ROMpak-2,3
ROMpak-4,5&6
ROMH12
VDC24
VDC12
VAC24
VAC110 V/1
220 V/1
220 V/3
380 V/3
440 V/3
ROMH-1
ROMH-2
ROMH-3
ROMpakH12
VDC24
VDC12
VAC24
VAC110 V/1
220 V/1
220 V/3
380 V/3
440 V/3
ROMpakH-1
ROMpakH-2
ROMpakH-3
Mechanical Data
Model ROMH Weight (kg)
ROMpakH Weight (kg)
Manual override
Output Drive (mm)
Mounting base designation to ISO5211 imperial
ROMH-1 2 4 Hexagonal Drive 14/11/9 F03/F05
ROMH-2 2 4 Hexagonal Drive 14/11/9 F03/F05
ROMH-3 2 4 Hexagonal Drive 14/11/9 F03/F05
Electrical Performance Data
DC Power Supply Torque (Nm)
Speed (Sec/90°) Motor Power (W)
Current (A) Run Lock
ROMH-112 VDC 8 5.5 4.75 1.2 2.2
24 VAC 8 4.5 4.75 0.65 1.2
ROMH-2 24 VDC 10 4.5 4.75 0.65 1.2
Single Phase
Power Supply Torque (Nm)
Speed (Sec/90°) 50Hz 60Hz
Motor Power (W)
Current (A) Run Lock
ROMH-3110 V 13 4.5 4.3 6.5 0.36 0.4
220 V 13 4.5 4.3 6.5 0.23 0.25
Single-Phase
ROMH and ROMpakH
* Note: ROMH-1, ROMH-2, ROMH-3, ROMpakH-1, ROMpakH-2, ROMpakH-3 are not suitable for butterfly valves which may back drive
A4 US
US
A4
US
A4
A4 US
ROM and ROMpak Range8
Circuit Diagram and Optional Extras
ROM Wiring Diagram
7
6
5
4
3
1
A
B
C
E
F
1011
12
SMOTOR
7 6 5 4 3 2 1
RY1 RY2
F RY2 RY1
LED 1
LED 2
HEATER
LS1
LS2
LS3
LS4
OPEN CLOSED
CLOSE
OPENOFF
SELECTORSWITCH
FULLY OPEN
FULLY CLOSED
MCB
12/24V AC/DC SUPPLY
(1) S CONNECTS TO 3 FOR“OPEN”, S CONNECTS TO 4FOR "CLOSE"
(2) HEATER,LS3,LS4,ANDPOTENTIONMETER AREOPTIONS.ROM 1 & ROM A
7
6
5
4
3
1
A
B
C
E
F
1011
12
HEATER
LS1
LS2
LS3
LS4
OPEN
ROM 1 & ROM A
CLOSED
CLOSE
OPENOFF
FULLY OPEN
FULLY CLOSED
(1) L CONNECTS TO 3 FOR“OPEN”, L CONNECTS TO 4
(2) HEATER,LS3,LS4 AND,POTENTIONMETER AREOPTIONS.
M1
N
LSELECTORSWITCH
MCB 110/220V AC1-PHASE
SINGLE PHASE
FOR "CLOSE"
SUPPLY
M1
7
6
5
4
3
1
A
B
C
D
E
F
1011
12
LS1
LS2
LS3
LS4
OPEN
ROM 2 3 4 5 6
CLOSED
CLOSE
OPENOFF
SELECTORSWITCH
FULLY OPEN
FULLY CLOSED
MCB
(1) L CONNECTS TO 3 FOR “OPEN”, L CONNECTS TO 4FOR "CLOSE"
(2) HEATER,LS3,LS4,TS1,TS2AND POTENTIONMETERARE OPTIONS.
N
L
110/220V AC1-PHASE
SINGLE PHASESUPPLY
TS1
TS2
HEATER
7
6
5
4
3
1
A
B
C
D
E
F
1011
12
P
SMOTOR
7 6 5 4 3 2 1
RY1 RY2
F RY2 RY1
LED 1
LED 2
HEATER
TS2
TS1 LS1
LS2
LS3
LS4
OPEN
ROM 2 3 4 5 6
CLOSED
CLOSE
OPENOFF
SELECTORSWITCH
FULLY OPEN
FULLY CLOSED
MCB Refer to table below
12/24V AC/DC SUPPLY
(1) S CONNECTS TO 3 FOR“OPEN”, S CONNECTS TO 4FOR "CLOSE"
(2) HEATER,LS3,LS4,TS1,TS2AND POTENTIONMETER AREOPTIONS.
9
8
6
5
A
B
C
3
W
V
U
4
1
LS3
HEATER
110/220V AC
LS1
LS2
TS1
TS2
M3 R
ST
L
N
MCB
MCB
FULLY OPEN
FULLY CLOSED
OPEN
CLOSEC 0
(1) 1 CONNECTS WITH 3 FOR “OPEN”,1 CONNECTS WITH 4 FOR“CLOSE”.
(2) IF THE ACTUATOR IS REVERSED
E
F
1011
12OPEN CLOSED
LS4
ROM 2 3 4 5 6THREE PHASE SUPPLY
(3) HEATER,LS3,LS4,TS1,TS2 ANDPOTENTIONMETER ARE OPTIONS.
OPERATION,PLEASE CHANGE TWO OF U,V AND W AT WILL.
Actuator Power supply P S 12V DC + - 24V DC + - 12V AC N L 24V AC N L
PRefer to table below
Actuator Power supply P S 12V DC + - 24V DC + - 12V AC N L 24V AC N L
Wiring Diagram ( ROM 1/A/2/3/4/5/6 ) Issue No: 4
3-PHASE SUPPLY
Optional Extras:
Torque Switches
Cam activated torque switches to provide torque overload protection ROM-2, 3, 4, 5 & 6.
Anti-condensation Heater
This heater is available for all sizes.
A4US
US
A4
US A4
US
A4
Keeping the World Flowing 9
Circuit Diagram and Optional Extras
ROMpak Three-Phase Wiring Diagram
V
E
W
HeaterU 1
2
3
4
LOCALCONTROLPCB
CLOSE-OPEN
STOPREMOTE-LOCAL
4
65
3
12
C1 C2
Z
XYMOTOR
U
V
YX Z
U
W
V
THREE PHASE
SUPPLY
CIRCUIT DRAWN WITHPOWER SUPPLY OFF
LIMITTORQUE
AND POSITIONSENSING
TRANSFORMER TAPPING
TAP
352-484 396-517
NOM 50/60HZ220/230380/400440/460
176-242304-418 342-446
198-25960HZ50HZ
SIR
1R
ELAY
1
3
5
SIR
2R
ELAY
2
4
6
NOTE
TO BE MINIMUM 'ON' 14V DC AT 1mA MAXIMUM 'OFF'=3V
MINIMUM CONTROL SIGNAL DURATIONTO BE 300mS.
CONTROL SIGNAL IS 5mA ON 24V DC CURRENT DRAWN FROM EACH REMOTE
MAX EXTERNAL LOAD ON S1/S2 RELAYS TO BE 5A. MAX VOLTAGE 120V AC/DC
NOT USED
CONTROL SIGNAL THRESHOLD VOLTAGES:MAX 60V DC
MONITOR
REMOTE SELECTED
SK.5
SK.17
SK.3
SK.8
1
2
3
4
5
OPEN
STOP/MAINTAIN
CLOSE
NOMINAL +VE 20-32V DC SUPPLY
6
7
8
9
10
OPEN COMMON
STOP/MAINTAIN COMMON
CLOSE COMMON ESD ESD COMMON
0V DC SUPPLY
SK.1
SK.1 SK.2
SK.24123456
1 2 3 4 SK.7
W
VOLTAGE SELECTOR
FS1FS1 - See ROMPAK E672E Installation and Maintenance Manual
S1
S2
FOR TYPICAL REMOTE CONTROLINDICATING,MONITORING AND ALARMCIRCUITS SEE PUBLICATION E621E
LS3 / LS4MAXIMUM CURRENT 3A MAXIMUMVOLTAGE 120V AC/DC
ACTUATOR CONFIGURATION VIA DIL SWITCH SW2
ROM1 DOES NOT SUPPORT TORQUE LIMIT
REFER TO INSTALLATION INSTRUCTIONS FOR DIL SWITCH SELECTION
MAX EXTERNAL LOAD ON TERMINAL27 & 28 TO BE 3W
LS3
LS4
7 8 9
10 11 12
5 6
13 14 15 16 17 18
19 20 21 22 23 24 25 26 27 28
A4 US
US
A4
US
A4
A4 US
ROM and ROMpak Range10
Dimensional Data
20mm Deep
M6 x1.0p10mm Deep4 Positions(ISO5211 F05)
M8x1.25p12mm Deep4 Positions(ISO5211 F07)
P.C.D 50
P.C.D 70
45°17 17
20mm Deep
Option for output shaft
14
11
170.
5
102
106
2 off M20 x1.5pConduit Entries
123
37
60
114 32 CTS
Conduit Entries
8
Manual overridemechanism
ROM-A
106102
123
114
32 CTSConduit Entries
2 off M20 x1.5pConduit Entries
M5 x0.8p9mm Deep4 Positions(ISO5211 F03)
M6 x1.0p10mm Deep4 Positions(ISO5211 F05)
60
136.
5(H
*)37
15mm Deep
P.C.D 36
P.C.D 50
45°
8
1414
20mm Deep 9
12
P.C.D 42
M5 x0.8p12mm Deep4 Positions(ISO5211 F04)
Option 2 for output shaft
H*=140
11
1420mm Deep
Option 1 for output shaft
H*=140
ROM-1ROMH-1ROMH-2ROMH-3
Flange type
F07 / F05
Flange type
F05 / F03
A4US
US
A4
US A4
US
A4
Keeping the World Flowing 11
Dimensional Data
ROM-2/3
ROM-4/5/6
Flange type
F07
Flange type
F10
209
180
196
115
M8 x1.25p10mm Deep4 Positions(ISO5211 F07)
70.00 P.C.D
45°
2 off M20 x1.5pConduit Entries
32 CTSConduit Entries
86.5
25mm Deep
345
246
252
H=/3
12*
22
22
110V, 220V AC 1-Phase
220V, 380V, 440V AC 3-Phase
213=HCD/CA V42 ,V21
ROM-2/3*H=252
140
22
25mm Deep
Option for output shaft17
*ROM-2/3
110 V, 220 V AC 1-PhaseH=252
220 V, 380 V, 440 V AC three-phase
12 V, 24 V AC/DC H=312
32 CTSConduit Entries
40mm Deep
268
102
228Ø
217Ø
318 (with torque limit switches) 249 (without torque limit switches)
434 (with torque limit switches) 365 (without torque limit switches)
160
Ø
327
45°
M10 x1.5p20mm Deep4 Positions(ISO5211 F10)
Ø 102.00 P.C.D
2 off M20 x1.5pConduit Entries 17
2
Option for output shaft
35 35
40mm Deep36
36
119
232
A4 US
US
A4
US
A4
A4 US
ROM and ROMpak Range12
Dimensional Data
20mm Deep
M8x1.25p12mm Deep4 Positions(ISO5211 F07)
M6 x1.0p10mm Deep4 Positions(ISO5211 F05)
P.C.D 70
P.C.D 50
45°
17 17
20mm Deep
Option for output shaft
14
11
170.
5
161
102106
215
225.
5
63
37
114
8
194
Manual overridemechanism
ROMpak-A
106
102
114
136.
5(H
*)37
15mm Deep
8
M5 x 0.8p9mm Deep4 Positions(ISO5211 F03)M6 x 1.0p10mm Deep4 Positions(ISO5211 F05)
215
63
161
225.
5
1414
P.C.D 50.00
P.C.D 36.00
45°
20mm Deep 9
12
P.C.D 42
M5 x 0.8p12mm Deep4 Positions(ISO5211 F04)
Option 2 for output shaft
H*=140
11
1420mm Deep
Option 1 for output shaft
H*=140
ROMpak-1, ROMpakH-1, ROMpakH-2, ROMpakH-3
Flange type
F07 / F05
Flange type
F05 / F03
A4US
US
A4
US A4
US
A4
Keeping the World Flowing 13
Dimensional Data
ROMpak-2/3
ROMpak-4/5/6
209
180
196
252
H=/3
12*
115
M8 x1.25p10mm Deep4 Positions(ISO5211 F07)
70.00 P.C.D
45°
86.5
25mm Deep
246
438
246
22
22
110V, 220V AC 1-Phase H=252
220V, 380V, 440V AC 3-Phase
12V, 24V AC/DC
*ROMpak 2/3H=312
140
22
25mm Deep
Option for output shaft17
Flange type
F07
Flange type
F10
*ROMpak-2/3
110 V, 220 V AC 1-Phase H=252
220 V, 380 V, 440 V AC three-phaseH=312
12 V, 24 V AC/DC
40mm Deep
268
102
228Ø
217Ø
318 (with torque limit switches)249 (without torque limit switches)
160
Ø
327
45°
M10 x1.5p20mm Deep4 Positions(ISO5211 F10)
Ø 102.00 P.C.D
527 (with torque limit switches )458 (without torque limit switches )
172
Option for output shaft
35 35
40mm Deep
3636
279
119
232
A4 US
US
A4
US
A4
A4 US
ROM and ROMpak Range14
Rotork actuators are recognised as the best in the world for reliability and safety in the most demanding applications. To maintain this hard-earned leadership position, Rotork Site Services is committed to helping clients to maximise the continuous, fault-free operation and working life of all their actuators.
With established operations and worldwide service centres we are able to offer same-day or next-day service to all our customers. Our Rotork factory trained engineers have skills in both multi-purpose and industry specific applications and carry with them spare parts and specialist test equipment. Our operations utilise a documented Quality Management system established in accordance with ISO9001.
Rotork Site Services aims to be your number one choice for taking care of fault diagnosis, service repairs, scheduled maintenance and system integration needs.
Rotork has expertise and specialist knowledge of every aspect of flow control.
Our service solutions increase plant efficiency and reduce maintenance costs.
Workshop services return equipment to as-new condition.
Client Support and Site Services
A4US
US
A4
US A4
US
A4
Keeping the World Flowing 15
Global Service and Support
Rotork understands the value of prompt and punctual customer site services and aim to supply our customers with superior flow control solutions, by providing high quality, innovative products and superior service – on time, every time.
Whether you have an actuator requiring on-site servicing, a custom design service requirement or a new actuator installation, we can deliver the fastest turnaround with the least plant disruption.
Accreditation and Assurance
Rotork Site Services is accredited with all major safety authorities around the world, providing our clients with reassurance and peace of mind.
Rotork's engineering teams are experts in the design and implementation of actuation solutions for all circumstances and environments. Our knowledge base draws upon previous installations and environmental situations from all around the world.
Our track record of undertaken engineering projects is second to none. Rotork is trusted by major utility and industrial companies throughout the world to design, install and maintain their actuation stock. We keep their plants operating at peak efficiency, helping them to be more profitable and at the same time meet ever tightening industry watchdog requirements.
We have the knowledge and expertise to design, build and install any standard or custom installation for you, anywhere throughout the world.
Asset Management
Rotork is a corporate member of the Institute of Asset Management, the professional body for whole life management of physical assets.
Actuator Workshop Overhaul
• Supporting all Rotork and non-Rotork products
• Workshop facilities including torque testing and re-coating
• Large OEM stock in all workshops
• Fully trained and experienced service engineers
• Fleet of well stocked service vehicles
• Loan actuator facilities
Field Support
• Site repairs
• Commissioning
• Upgrades
• Fault finding
• Maintenance
• Call-out
• Fully equiped service vehicles
Rotork Client Support Programme (CSP)
• Enables users to select a level of service precisely tailored for their individual asset management requirements
• Designed to provide the maximum reliability and availability of actuators over the life of the product – thereby improving production throughput
• Designed to reduce the cost of maintenance year on year
• Designed to allow customers to manage the problem of ‘Risk vs Budget’ in maintenance operations
• Designed to be flexible – you choose the level of cover you want
• Reports generated on agreed frequency to demonstrate cost savings and performance improvements
Turnaround, Shutdown and Outage Support
• Preventative maintenance
• Full on-site overhaul and testing facilities
• OEM spares and support
• Support for Rotork and non-Rotork products
• Commissioning support to achieve shutdown time targets
• Project management and supervision of your plant overhaul and return to service dates
Valve Automation Centres
• On Site – Manual Valve Automation
• On Site – Actuator Replacement
• Off Site – New Valve Automation
Giving You Peace of Mind, Guaranteed Quality and
Improving Your Site Efficiency
Client Support and Site Services
A4 US
US
A4
US
A4
A4 US
Rotork plcBrassmill Lane, Bath, UK
tel +44 (0)1225 733200fax +44 (0)1225 333467email [email protected]
As part of a process of on-going product development, Rotork reserves the right to amend and change specifications without prior notice. Published data may be subject to change. For the very latest version release, visit our website at www.rotork.com
The name Rotork is a registered trademark. Rotork recognises all registered trademarks. The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rotork is under license. Published and produced in the UK by Rotork Controls Limited. POWJB1016
www.rotork.com
A full listing of our worldwide sales and service network is available on our website.
Rotork is a corporate member of the Institute of Asset Management
PUB008-001-00Issue 10/16
A4US
US
A4
US A4
US
A4