rohs pat.p. - 東洋技研株式会社 · advantage atx-10 has two fixed types. replace between...
TRANSCRIPT
UP-SCREW TYPERoHS PAT.P.
※Supply method: Assembly terminal blocks only.
※Supply method: Assembly terminal blocks only.
ATXRL-10-□PATXRL-10-□PLocked by lever type:Locked by lever type:
ATXSL-10-□PATXSL-10-□PLocked by screw type:Locked by screw type:
upper side (A)…modified PPE (Gray)under side (B)…modified PPE (Black)Flat nut
Fixation screw
Spring
Advantage ATX-10 has two fixed types.
Replace
Between panel and panel connection
Check / Test / Maintenance
Replace
Standardization
If ATX series is used when replacing, the stop time of the production line can be shortened.
You must remove screw one by one
It is possible to detach electric wire all together.
Rated voltage
Applicable wire / Rated current
Terminal screw
Tightening torque
Withstand voltage
Insulation resistance
Operating ambient temperature
Relative humidity
Contact resistance
Durability
Applicable standard
Body insulator
Contact(under)Conductive plate(upper)Terminal screw
Coil spring
Terminal plate
Locked by screw type end plate
Lock
Lever
−
Cover
Name plate
modified PPE(Black)Cooper alloy (Ni plate)Cooper alloy (Sn plate)Steel (zinc trivalent chromate–plating)
Hard steel wire(zinc trivalent chromate–plating)Steel (zinc trivalent chromate–plating)upper side (A)…PBT(Gray),
under side (B) …modified PPE(Black)
modified PPE (Gray)
modified PPE (Black)
PC (Clear)PVC (White)
600 V
2㎜2 / 16A
M3.5 x6.7L
1.4N・m
2500 V / 1 min
200 MΩ or more(DC500 V mega)−25℃~+60℃(no freezing or condensation)45 ~85 %
5 MΩ or less
200 times
JIS C 8201-7-1(NECA C 2811)
It is possible to shorten time toconnect and I/O check.
It is possible to shorten test time when the product is used in test equipment.
New Control Panel
Control Panel Control Panel
Control Panel Control Panel Control Panel
New Control PanelMaster Control Panel Master Control PanelExisting control board
Test equipment
Existing control board
Power line(TB)
Standardization of connection
Signal line(CN)
Combine(ATX Series)
Locked by lever type:
■ Rating and Specification
■ Material
■ Applicable solderless terminal
Locked by screw type:
ATXRL-10-□P ATXSL-10-□P
Items ATXRL-10-□P ATXSL-10-□P
(for mount upper on under)
Steel (zinc trivalent chromate –plating)
Steel (zinc trivalent chromate –plating)
modified PPE (Gray)
upper side (A)…modified PPE (Gray)under side (B)…modified PPE (Black)Flat nut
Fixation screw
Spring
Advantage ATX-10 has two fixed types.
Replace
Between panel and panel connection
Check / Test / Maintenance
Replace
Standardization
If ATX series is used when replacing, the stop time of the production line can be shortened.
You must remove screw one by one
It is possible to detach electric wire all together.
Rated voltage
Applicable wire / Rated current
Terminal screw
Tightening torque
Withstand voltage
Insulation resistance
Operating ambient temperature
Relative humidity
Contact resistance
Durability
Applicable standard
Body insulator
Contact(under)Conductive plate(upper)Terminal screw
Coil spring
Terminal plate
Locked by screw type end plate
Lock
Lever
−
Cover
Name plate
modified PPE(Black)Cooper alloy (Ni plate)Cooper alloy (Sn plate)Steel (zinc trivalent chromate–plating)
Hard steel wire(zinc trivalent chromate–plating)Steel (zinc trivalent chromate–plating)upper side (A)…PBT(Gray),
under side (B) …modified PPE(Black)
modified PPE (Gray)
modified PPE (Black)
PC (Clear)PVC (White)
600 V
2㎜2 / 16A
M3.5 x6.7L
1.4N・m
2500 V / 1 min
200 MΩ or more(DC500 V mega)−25℃~+60℃(no freezing or condensation)45 ~85 %
5 MΩ or less
200 times
JIS C 8201-7-1(NECA C 2811)
It is possible to shorten time toconnect and I/O check.
It is possible to shorten test time when the product is used in test equipment.
New Control Panel
Control Panel Control Panel
Control Panel Control Panel Control Panel
New Control PanelMaster Control Panel Master Control PanelExisting control board
Test equipment
Existing control board
Power line(TB)
Standardization of connection
Signal line(CN)
Combine(ATX Series)
Locked by lever type:
■ Rating and Specification
■ Material
■ Applicable solderless terminal
Locked by screw type:
ATXRL-10-□P ATXSL-10-□P
Items ATXRL-10-□P ATXSL-10-□P
(for mount upper on under)
Steel (zinc trivalent chromate –plating)
Steel (zinc trivalent chromate –plating)
modified PPE (Gray)
Dimensions (㎜)
ATXRL-10 -□P Component
More information is available at TOGI homepage
※Supply method: Assembly terminal blocks only.
The following parts are assembled at the factory and shipped.( Terminal blocks, End plates, Cover, Name plate, Din rail, Stoppers )
①Release the lock.
①When you released the lock,it appeared insertion hole for lever.Then insert screwdriver to the hole.
②Down the screwdriver,push up the upper terminal block.
③Operate the lever same as ②.Detach the upper terminal.
②Down the lever, detach the upper terminal block.
Locked by lever type:ATXRL-10-□P
2
52
80
70
100
3
60
80
70
111
4
68
100
90
127
5
76
100
90
138
6
84
100
90
150
7
92
120
110
165
8
100
120
110
177
9
108
140
130
192
10
116
140
130
203
11
124
140
130
215
12
132
160
150
230
13
140
160
150
242
14
148
180
170
257
15
156
180
170
268
16
164
180
170
280
17
172
200
190
295
18
180
200
190
307
19
188
220
210
322
20
196
220
210
334
ATX-10〔10.9g〕 CB-5 M-1LE DAV4 ATX-10-CP1(Option) ATX-10-SP
S B(R)8A-※□B(R)8A-※
ATX-10L1R(A)(B)〔15.6g〕ATX-10L2R(A)(B)〔8.9g〕
No. of poles(P)
Total length of terminal block(L)
Total length of DIN rail(A)Mounting hole pitch(B)
Mass of assembled terminal block(g)
End plate set Cover Name plate Rail Stopper Prevent misinsert plate Spacer OptionTerminal block
Total length of terminal block(L) = Terminal width(8㎜)× No.of poles(P) + End plates / stoppers (36㎜)
FEATURES
It’s easy to detach the product even in narrow place.
How to detach by using lever
How to operate the lever by using screw driver
Screwdriver
Insertion holefor lever operation
ATXRL-10-□P □:No.of poles(P)
(□=2~20)
Order format:
GTY-13〔18.0g〕
Dimensions (㎜)
ATXRL-10 -□P Component
More information is available at TOGI homepage
※Supply method: Assembly terminal blocks only.
The following parts are assembled at the factory and shipped.( Terminal blocks, End plates, Cover, Name plate, Din rail, Stoppers )
①Release the lock.
①When you released the lock,it appeared insertion hole for lever.Then insert screwdriver to the hole.
②Down the screwdriver,push up the upper terminal block.
③Operate the lever same as ②.Detach the upper terminal.
②Down the lever, detach the upper terminal block.
Locked by lever type:ATXRL-10-□P
2
52
80
70
100
3
60
80
70
111
4
68
100
90
127
5
76
100
90
138
6
84
100
90
150
7
92
120
110
165
8
100
120
110
177
9
108
140
130
192
10
116
140
130
203
11
124
140
130
215
12
132
160
150
230
13
140
160
150
242
14
148
180
170
257
15
156
180
170
268
16
164
180
170
280
17
172
200
190
295
18
180
200
190
307
19
188
220
210
322
20
196
220
210
334
ATX-10〔10.9g〕 CB-5 M-1LE DAV4 ATX-10-CP1(Option) ATX-10-SP
S B(R)8A-※□B(R)8A-※
ATX-10L1R(A)(B)〔15.6g〕ATX-10L2R(A)(B)〔8.9g〕
No. of poles(P)
Total length of terminal block(L)
Total length of DIN rail(A)Mounting hole pitch(B)
Mass of assembled terminal block(g)
End plate set Cover Name plate Rail Stopper Prevent misinsert plate Spacer OptionTerminal block
Total length of terminal block(L) = Terminal width(8㎜)× No.of poles(P) + End plates / stoppers (36㎜)
FEATURES
It’s easy to detach the product even in narrow place.
How to detach by using lever
How to operate the lever by using screw driver
Screwdriver
Insertion holefor lever operation
ATXRL-10-□P □:No.of poles(P)
(□=2~20)
Order format:
GTY-13〔18.0g〕
Dimensions (㎜)
ATXSL-10 -□P Component
※Supply method: Assembly terminal blocks only.
The following parts are assembled at the factory and shipped.( Terminal blocks, End plates, Cover, Name plate, Din rail, Stoppers )
※1unit = 2P~20P※Please fix the rail with over triple site, if(X) is over 500 ㎜ .
When it is locked,insertion hole will be closed.
When it is locked,it won’t be moved
Locked by Screw type:ATXRL-10-□P
ATX-10〔10.9g〕 CB-5 M-1LE DAV4 ATX-10-CP1(Option) ATX-10-SP
GTY-13〔18.0g〕
ATX-10L1(A)(B)〔9.5g〕ATX-10L2(A)(B)〔11.5g〕
No. of poles(P)
Total length of terminal block(L)
Total length of DIN rail(A)Mounting hole pitch(B)
Mass of assembled terminal block(g)
End plate set Cover Name plate Rail Stopper Prevent misinsert plate Spacer OptionTerminal block
Total length of terminal block(L) = Terminal width(8㎜)× No.of poles(P) + End plates / stoppers (20㎜)
ATXSL-10-□P □:No.of poles(P)
(□=2~20)
SLIDE LOCK STRUCTURE
It is possible to successively attach on the same rail as follow.
Locked position Unlocked position
Unit 1 Unit 2
Unit 1 Unit 2
Spacer for adjacent install(locked by lever only)
It is possible to check just by looking.
Length of total terminal block(L) = 〔Terminal width (8㎜) ×No. of poles(P)〕 + 〔32㎜ ×No. of units〕+ 4㎜
When installing side by side on the rail, Spacer is used between the units to prevent mutual interference.
Space among units 2㎜
Fix with stopper ”GTY13” for both ends of unit
Total length of terminal block(L)Length of the rail(X)
2
36
80
70
96
3
44
80
70
108
4
52
100
90
123
5
60
100
90
135
6
68
100
90
146
7
76
120
110
162
8
84
120
110
173
9
92
140
130
188
10
100
140
130
200
11
108
140
130
211
12
116
160
150
227
13
124
160
150
238
14
132
180
170
253
15
140
180
170
265
16
148
180
170
276
17
156
200
190
292
18
164
200
190
303
19
172
220
210
319
20
180
220
210
330
Order format:
S B(R)8A-※□B(R)8A-※
Dimensions (㎜)
ATXSL-10 -□P Component
※Supply method: Assembly terminal blocks only.
The following parts are assembled at the factory and shipped.( Terminal blocks, End plates, Cover, Name plate, Din rail, Stoppers )
※1unit = 2P~20P※Please fix the rail with over triple site, if(X) is over 500 ㎜ .
When it is locked,insertion hole will be closed.
When it is locked,it won’t be moved
Locked by Screw type:ATXRL-10-□P
ATX-10〔10.9g〕 CB-5 M-1LE DAV4 ATX-10-CP1(Option) ATX-10-SP
GTY-13〔18.0g〕
ATX-10L1(A)(B)〔9.5g〕ATX-10L2(A)(B)〔11.5g〕
No. of poles(P)
Total length of terminal block(L)
Total length of DIN rail(A)Mounting hole pitch(B)
Mass of assembled terminal block(g)
End plate set Cover Name plate Rail Stopper Prevent misinsert plate Spacer OptionTerminal block
Total length of terminal block(L) = Terminal width(8㎜)× No.of poles(P) + End plates / stoppers (20㎜)
ATXSL-10-□P □:No.of poles(P)
(□=2~20)
SLIDE LOCK STRUCTURE
It is possible to successively attach on the same rail as follow.
Locked position Unlocked position
Unit 1 Unit 2
Unit 1 Unit 2
Spacer for adjacent install(locked by lever only)
It is possible to check just by looking.
Length of total terminal block(L) = 〔Terminal width (8㎜) ×No. of poles(P)〕 + 〔32㎜ ×No. of units〕+ 4㎜
When installing side by side on the rail, Spacer is used between the units to prevent mutual interference.
Space among units 2㎜
Fix with stopper ”GTY13” for both ends of unit
Total length of terminal block(L)Length of the rail(X)
2
36
80
70
96
3
44
80
70
108
4
52
100
90
123
5
60
100
90
135
6
68
100
90
146
7
76
120
110
162
8
84
120
110
173
9
92
140
130
188
10
100
140
130
200
11
108
140
130
211
12
116
160
150
227
13
124
160
150
238
14
132
180
170
253
15
140
180
170
265
16
148
180
170
276
17
156
200
190
292
18
164
200
190
303
19
172
220
210
319
20
180
220
210
330
Order format:
S B(R)8A-※□B(R)8A-※
3000-14-08
Option parts
※Do not push the upper terminal block strongly when it is not a pair. Breakage may occur.
Plate for prevention of incorrect insertion
Operating precautions
Plate, separated
Please insert the plate deeply.
Control panel B
Control panelA
Control panel A
Control panelB
Control panel C
Control panelC
Control panel D
Control panelD
※Don’t attach / detach terminals when applying current.
※Locked by screw type… Make sure to tighten up a fixation screw after assembling upper and under terminal block.
※Locked by lever type… Please slide the lever to fixed position to remain lock after assembling upper and under terminal block.
①Insert a plate for the prevention of incorrect insertion in the under terminal blocks.
③When it is not a right pair, the terminal block cannot be connected.
②Cut the boss of the pairing upper terminal blocks with nippers.
ATX-10-CP1(Option)
Distributor
4-8-7 Gongencho, Osachi, Okaya-shi, Nagano-ken Japan 394-0081http://www.togi.co.jpE-mail: [email protected]