rohs pat.p. - 東洋技研株式会社 · advantage atx-10 has two fixed types. replace between...

8
UP-SCREW TYPE RoHS PAT.P. ※Supply method: Assembly terminal blocks only. ※Supply method: Assembly terminal blocks only. ATXRL-10-P ATXRL-10-P Locked by lever type: Locked by lever type: ATXSL-10-P ATXSL-10-P Locked by screw type: Locked by screw type:

Upload: others

Post on 06-Oct-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RoHS PAT.P. - 東洋技研株式会社 · Advantage ATX-10 has two fixed types. Replace Between panel and panel connection Check / Test / Maintenance Replace Standardization If ATX

UP-SCREW TYPERoHS PAT.P.

※Supply method:  Assembly terminal blocks only.

※Supply method:  Assembly terminal blocks only.

ATXRL-10-□PATXRL-10-□PLocked by lever type:Locked by lever type:

ATXSL-10-□PATXSL-10-□PLocked by screw type:Locked by screw type:

Page 2: RoHS PAT.P. - 東洋技研株式会社 · Advantage ATX-10 has two fixed types. Replace Between panel and panel connection Check / Test / Maintenance Replace Standardization If ATX

upper side (A)…modified PPE (Gray)under side (B)…modified PPE (Black)Flat nut

Fixation screw

Spring

Advantage ATX-10 has two fixed types.

Replace

Between panel and panel connection

Check / Test / Maintenance

Replace

Standardization

If ATX series is used when replacing, the stop time of the production line can be shortened.

You must remove screw one by one

It is possible to detach electric wire all together.

Rated voltage

Applicable wire / Rated current

Terminal screw

Tightening torque

Withstand voltage

Insulation resistance

Operating ambient temperature

Relative humidity

Contact resistance

Durability

Applicable standard

Body insulator

Contact(under)Conductive plate(upper)Terminal screw

Coil spring

Terminal plate

Locked by screw type end plate

Lock

Lever

Cover

Name plate

modified PPE(Black)Cooper alloy (Ni plate)Cooper alloy (Sn plate)Steel (zinc trivalent chromate–plating)

Hard steel wire(zinc trivalent chromate–plating)Steel (zinc trivalent chromate–plating)upper side (A)…PBT(Gray),

under side (B) …modified PPE(Black)

modified PPE (Gray)

modified PPE (Black)

PC (Clear)PVC (White)

600 V

2㎜2 / 16A

M3.5 x6.7L

1.4N・m

2500 V / 1 min

200 MΩ or more(DC500 V mega)−25℃~+60℃(no freezing or condensation)45 ~85 %

5 MΩ or less

200 times

JIS C 8201-7-1(NECA C 2811)

It is possible to shorten time toconnect and I/O check.

It is possible to shorten test time when the product is used in test equipment.

New Control Panel

Control Panel Control Panel

Control Panel Control Panel Control Panel

New Control PanelMaster Control Panel Master Control PanelExisting control board

Test equipment

Existing control board

Power line(TB)

Standardization of connection

Signal line(CN)

Combine(ATX Series)

Locked by lever type:

■ Rating and Specification

■ Material

■ Applicable solderless terminal

Locked by screw type:

ATXRL-10-□P ATXSL-10-□P

Items ATXRL-10-□P ATXSL-10-□P

(for mount upper on under)

Steel (zinc trivalent chromate –plating)

Steel (zinc trivalent chromate –plating)

modified PPE (Gray)

Page 3: RoHS PAT.P. - 東洋技研株式会社 · Advantage ATX-10 has two fixed types. Replace Between panel and panel connection Check / Test / Maintenance Replace Standardization If ATX

upper side (A)…modified PPE (Gray)under side (B)…modified PPE (Black)Flat nut

Fixation screw

Spring

Advantage ATX-10 has two fixed types.

Replace

Between panel and panel connection

Check / Test / Maintenance

Replace

Standardization

If ATX series is used when replacing, the stop time of the production line can be shortened.

You must remove screw one by one

It is possible to detach electric wire all together.

Rated voltage

Applicable wire / Rated current

Terminal screw

Tightening torque

Withstand voltage

Insulation resistance

Operating ambient temperature

Relative humidity

Contact resistance

Durability

Applicable standard

Body insulator

Contact(under)Conductive plate(upper)Terminal screw

Coil spring

Terminal plate

Locked by screw type end plate

Lock

Lever

Cover

Name plate

modified PPE(Black)Cooper alloy (Ni plate)Cooper alloy (Sn plate)Steel (zinc trivalent chromate–plating)

Hard steel wire(zinc trivalent chromate–plating)Steel (zinc trivalent chromate–plating)upper side (A)…PBT(Gray),

under side (B) …modified PPE(Black)

modified PPE (Gray)

modified PPE (Black)

PC (Clear)PVC (White)

600 V

2㎜2 / 16A

M3.5 x6.7L

1.4N・m

2500 V / 1 min

200 MΩ or more(DC500 V mega)−25℃~+60℃(no freezing or condensation)45 ~85 %

5 MΩ or less

200 times

JIS C 8201-7-1(NECA C 2811)

It is possible to shorten time toconnect and I/O check.

It is possible to shorten test time when the product is used in test equipment.

New Control Panel

Control Panel Control Panel

Control Panel Control Panel Control Panel

New Control PanelMaster Control Panel Master Control PanelExisting control board

Test equipment

Existing control board

Power line(TB)

Standardization of connection

Signal line(CN)

Combine(ATX Series)

Locked by lever type:

■ Rating and Specification

■ Material

■ Applicable solderless terminal

Locked by screw type:

ATXRL-10-□P ATXSL-10-□P

Items ATXRL-10-□P ATXSL-10-□P

(for mount upper on under)

Steel (zinc trivalent chromate –plating)

Steel (zinc trivalent chromate –plating)

modified PPE (Gray)

Page 4: RoHS PAT.P. - 東洋技研株式会社 · Advantage ATX-10 has two fixed types. Replace Between panel and panel connection Check / Test / Maintenance Replace Standardization If ATX

Dimensions (㎜)

ATXRL-10 -□P Component

More information is available at TOGI homepage

※Supply method: Assembly terminal blocks only.

The following parts are assembled at the factory and shipped.( Terminal blocks, End plates, Cover, Name plate, Din rail, Stoppers )

①Release the lock.

①When you released the lock,it appeared insertion hole for lever.Then insert screwdriver to the hole.

②Down the screwdriver,push up the upper terminal block.

③Operate the lever same as ②.Detach the upper terminal.

②Down the lever,  detach the upper terminal block.

Locked by lever type:ATXRL-10-□P

2

52

80

70

100

3

60

80

70

111

4

68

100

90

127

5

76

100

90

138

6

84

100

90

150

7

92

120

110

165

8

100

120

110

177

9

108

140

130

192

10

116

140

130

203

11

124

140

130

215

12

132

160

150

230

13

140

160

150

242

14

148

180

170

257

15

156

180

170

268

16

164

180

170

280

17

172

200

190

295

18

180

200

190

307

19

188

220

210

322

20

196

220

210

334

ATX-10〔10.9g〕 CB-5 M-1LE DAV4 ATX-10-CP1(Option) ATX-10-SP

S B(R)8A-※□B(R)8A-※

ATX-10L1R(A)(B)〔15.6g〕ATX-10L2R(A)(B)〔8.9g〕

No. of poles(P)

Total length of terminal block(L)

Total length of DIN rail(A)Mounting hole pitch(B)

Mass of assembled terminal block(g)

End plate set Cover Name plate Rail Stopper Prevent misinsert plate Spacer OptionTerminal block

Total length of terminal block(L) = Terminal width(8㎜)× No.of poles(P) + End plates / stoppers (36㎜)

FEATURES

It’s easy to detach the product even in narrow place.

How to detach by using lever

How to operate the lever by using screw driver

Screwdriver

Insertion holefor lever operation

ATXRL-10-□P □:No.of poles(P)

(□=2~20)

Order format:

GTY-13〔18.0g〕

Page 5: RoHS PAT.P. - 東洋技研株式会社 · Advantage ATX-10 has two fixed types. Replace Between panel and panel connection Check / Test / Maintenance Replace Standardization If ATX

Dimensions (㎜)

ATXRL-10 -□P Component

More information is available at TOGI homepage

※Supply method: Assembly terminal blocks only.

The following parts are assembled at the factory and shipped.( Terminal blocks, End plates, Cover, Name plate, Din rail, Stoppers )

①Release the lock.

①When you released the lock,it appeared insertion hole for lever.Then insert screwdriver to the hole.

②Down the screwdriver,push up the upper terminal block.

③Operate the lever same as ②.Detach the upper terminal.

②Down the lever,  detach the upper terminal block.

Locked by lever type:ATXRL-10-□P

2

52

80

70

100

3

60

80

70

111

4

68

100

90

127

5

76

100

90

138

6

84

100

90

150

7

92

120

110

165

8

100

120

110

177

9

108

140

130

192

10

116

140

130

203

11

124

140

130

215

12

132

160

150

230

13

140

160

150

242

14

148

180

170

257

15

156

180

170

268

16

164

180

170

280

17

172

200

190

295

18

180

200

190

307

19

188

220

210

322

20

196

220

210

334

ATX-10〔10.9g〕 CB-5 M-1LE DAV4 ATX-10-CP1(Option) ATX-10-SP

S B(R)8A-※□B(R)8A-※

ATX-10L1R(A)(B)〔15.6g〕ATX-10L2R(A)(B)〔8.9g〕

No. of poles(P)

Total length of terminal block(L)

Total length of DIN rail(A)Mounting hole pitch(B)

Mass of assembled terminal block(g)

End plate set Cover Name plate Rail Stopper Prevent misinsert plate Spacer OptionTerminal block

Total length of terminal block(L) = Terminal width(8㎜)× No.of poles(P) + End plates / stoppers (36㎜)

FEATURES

It’s easy to detach the product even in narrow place.

How to detach by using lever

How to operate the lever by using screw driver

Screwdriver

Insertion holefor lever operation

ATXRL-10-□P □:No.of poles(P)

(□=2~20)

Order format:

GTY-13〔18.0g〕

Page 6: RoHS PAT.P. - 東洋技研株式会社 · Advantage ATX-10 has two fixed types. Replace Between panel and panel connection Check / Test / Maintenance Replace Standardization If ATX

Dimensions (㎜)

ATXSL-10 -□P Component

※Supply method: Assembly terminal blocks only.

The following parts are assembled at the factory and shipped.( Terminal blocks, End plates, Cover, Name plate, Din rail, Stoppers )

※1unit = 2P~20P※Please fix the rail with over triple site, if(X) is over 500 ㎜ .

When it is locked,insertion hole will be closed.

When it is locked,it won’t be moved

Locked by Screw type:ATXRL-10-□P

ATX-10〔10.9g〕 CB-5 M-1LE DAV4 ATX-10-CP1(Option) ATX-10-SP

GTY-13〔18.0g〕

ATX-10L1(A)(B)〔9.5g〕ATX-10L2(A)(B)〔11.5g〕

No. of poles(P)

Total length of terminal block(L)

Total length of DIN rail(A)Mounting hole pitch(B)

Mass of assembled terminal block(g)

End plate set Cover Name plate Rail Stopper Prevent misinsert plate Spacer OptionTerminal block

Total length of terminal block(L) = Terminal width(8㎜)× No.of poles(P) + End plates / stoppers (20㎜)

ATXSL-10-□P □:No.of poles(P)

(□=2~20)

SLIDE LOCK STRUCTURE

It is possible to successively attach on the same rail as follow.

Locked position Unlocked position

Unit 1 Unit 2

Unit 1 Unit 2

Spacer for adjacent install(locked by lever only)

It is possible to check just by looking.

Length of total terminal block(L) = 〔Terminal width (8㎜) ×No. of poles(P)〕 + 〔32㎜ ×No. of units〕+ 4㎜

When installing side by side on the rail, Spacer is used between the units to prevent mutual interference.

Space among units 2㎜

Fix with stopper ”GTY13” for both ends of unit

Total length of terminal block(L)Length of the rail(X)

2

36

80

70

96

3

44

80

70

108

4

52

100

90

123

5

60

100

90

135

6

68

100

90

146

7

76

120

110

162

8

84

120

110

173

9

92

140

130

188

10

100

140

130

200

11

108

140

130

211

12

116

160

150

227

13

124

160

150

238

14

132

180

170

253

15

140

180

170

265

16

148

180

170

276

17

156

200

190

292

18

164

200

190

303

19

172

220

210

319

20

180

220

210

330

Order format:

S B(R)8A-※□B(R)8A-※

Page 7: RoHS PAT.P. - 東洋技研株式会社 · Advantage ATX-10 has two fixed types. Replace Between panel and panel connection Check / Test / Maintenance Replace Standardization If ATX

Dimensions (㎜)

ATXSL-10 -□P Component

※Supply method: Assembly terminal blocks only.

The following parts are assembled at the factory and shipped.( Terminal blocks, End plates, Cover, Name plate, Din rail, Stoppers )

※1unit = 2P~20P※Please fix the rail with over triple site, if(X) is over 500 ㎜ .

When it is locked,insertion hole will be closed.

When it is locked,it won’t be moved

Locked by Screw type:ATXRL-10-□P

ATX-10〔10.9g〕 CB-5 M-1LE DAV4 ATX-10-CP1(Option) ATX-10-SP

GTY-13〔18.0g〕

ATX-10L1(A)(B)〔9.5g〕ATX-10L2(A)(B)〔11.5g〕

No. of poles(P)

Total length of terminal block(L)

Total length of DIN rail(A)Mounting hole pitch(B)

Mass of assembled terminal block(g)

End plate set Cover Name plate Rail Stopper Prevent misinsert plate Spacer OptionTerminal block

Total length of terminal block(L) = Terminal width(8㎜)× No.of poles(P) + End plates / stoppers (20㎜)

ATXSL-10-□P □:No.of poles(P)

(□=2~20)

SLIDE LOCK STRUCTURE

It is possible to successively attach on the same rail as follow.

Locked position Unlocked position

Unit 1 Unit 2

Unit 1 Unit 2

Spacer for adjacent install(locked by lever only)

It is possible to check just by looking.

Length of total terminal block(L) = 〔Terminal width (8㎜) ×No. of poles(P)〕 + 〔32㎜ ×No. of units〕+ 4㎜

When installing side by side on the rail, Spacer is used between the units to prevent mutual interference.

Space among units 2㎜

Fix with stopper ”GTY13” for both ends of unit

Total length of terminal block(L)Length of the rail(X)

2

36

80

70

96

3

44

80

70

108

4

52

100

90

123

5

60

100

90

135

6

68

100

90

146

7

76

120

110

162

8

84

120

110

173

9

92

140

130

188

10

100

140

130

200

11

108

140

130

211

12

116

160

150

227

13

124

160

150

238

14

132

180

170

253

15

140

180

170

265

16

148

180

170

276

17

156

200

190

292

18

164

200

190

303

19

172

220

210

319

20

180

220

210

330

Order format:

S B(R)8A-※□B(R)8A-※

Page 8: RoHS PAT.P. - 東洋技研株式会社 · Advantage ATX-10 has two fixed types. Replace Between panel and panel connection Check / Test / Maintenance Replace Standardization If ATX

3000-14-08

Option parts

※Do not push the upper terminal block strongly when it is not a pair. Breakage may occur.

Plate for prevention of incorrect insertion

Operating precautions

Plate, separated

Please insert the plate deeply.

Control panel B

Control panelA

Control panel A

Control panelB

Control panel C

Control panelC

Control panel D

Control panelD

※Don’t attach / detach terminals when applying current.

※Locked by screw type… Make sure to tighten up a fixation screw after assembling upper and under terminal block.

※Locked by lever type… Please slide the lever to fixed position to remain lock after assembling upper and under terminal block.

①Insert a plate for the prevention of incorrect insertion in the under terminal blocks.

③When it is not a right pair, the terminal block cannot be connected.

②Cut the boss of the pairing upper terminal blocks with nippers.

ATX-10-CP1(Option)

Distributor

4-8-7 Gongencho, Osachi, Okaya-shi, Nagano-ken Japan 394-0081http://www.togi.co.jpE-mail: [email protected]