robusta pm - ascenseurs-online · robusta pm automatic horizontal sliding car door...
TRANSCRIPT
ROBUSTA PM
www.fermator.com
Automatic horizontal sliding car door
DOC-FECMCBPRUC00ENPRINTABLE VERSION: 27-04-2015ENG
CommercialResidential Service lifts
www.fermator.com 2Robusta PM
APPLICATION RANGE
Opening Clear opening - PL Clear height - HL
Inches mm Inches mmC2 30 - 59 750 - 1.500
70 7/8 - 157 1/2 1.800 - 4.000T1 24 - 45 600 - 1.150T2 30 - 72 750 - 1.829
Door configuration
PROTECTION
Opening
IP21Protection against a solid foreign body of 12,5 mm or more in diameter and
protected against vertically falling drops of water.
IPX3Protected against sprays of water up to 60 degrees from
the vertical.
IP54Protection against dust and
protected against water splashed from all directions.
IP65Sealed against dust and
protected against jets of water from all directions.
EExExplosion proof, Group II (surface
industries) and Category 2 (explosive atmosphere between
10 and 1.000 hrs/yr).
C2 T1 - T2
SILLS
Type of sill Aluminium Reinforced aluminium Steel* Massive* Steel hidden* Brass
Profile detail - - -
Availability
Heated sill option
Dust holes Sill support
*Stainless steel / Galvanized.
PANELS
Opening
Steel panels Glass panels
Metal sheet
Double skin Vision Gridded
vision
Wien type
visionBevel big
visionFlush big
vision Full glassFull glass
built in moorings
Full glass hidden trims
Aluminium glass
WC2
T1 - T2
STANDARDS
Opening EN 81-1/2Safety rules
EN 81-21Existing buildings
EN 81-41Impaired mobility
EN 81-71Vandal resistance lifts
EN 81-72Firefighters
lifts
EN 81-20/50Safety rules ASME A17.1
Cat. I Cat. IIC2
T1 - T2
LIFT APPLICATION Door cycles per year: Up to 2.500.000.Traffic peak of the door: Up to 360 cycles per hour.
Traffic lift speed: Up to 6 m/s.
Available1. Ask the commercial department.Not available.1Some option combinations may not be possible.
www.fermator.com3 Robusta PM
Door configuration
SAFETY DEVICES
Opening Photocell Photoelectric barrier Safety edge Emergency power supplyStatic Dynamic* Dynamic deep** VF5+ VF6
C2 T1 - T2
* Safety barrier 10 or 15 mm deep.** Safety barrier 45 mm deep for T1 - T2, 30 mm for C2.
PANEL REGULATION SUPPORT AND PANEL GUIDE
Type of panel regulation support Direct fastening
Type of panel guide Plus
COMPATIBILITY
±030 130130
260
150
130
260
390
AFO: HL + 220
HL
H
MO
TOR
Case Robusta landing doorCoupling Symmetrical clutch
Unlocking zone +130 / -130Toe guard type Big
H 750Thickness 1,5
Range AllT2 opening shown.
If not otherwise indicated all dimensions in mm.
Available1. Ask the commercial department.Not available.1Some option combinations may not be possible.
www.fermator.com 4Robusta PM
T2 operator
ELECTRONIC MODULEType VF5+ and VF6.
Adjustable parameters via PC / Console.Working signals available From 12 V to 240 V AC/DC or with BUS CAN.
Opening speed Up to 1 m/s (Regulable).Closing speed Up to 0,4 m/s. Auto-adjustable directly with the panel weight.
Re-opening Integrated with auto-adjustable cycles.
OTHER FEATURESNoise level < 51 dB.Total weight Reference: T1 PL 800 mm HL 2.000 mm with sheet metal panels - 99,5 kg.
Maximum moving mass 360 kg.Locking device Robusta Restrictor.
INSTALLATIONPre-adjusted and tested to simplify the installation.
Frontal concept, all parts within the sill projection, allows fixing directly to the front or by an adjustable range of brackets.
Technical features
DRIVEType Synchronous brushless permanent magnets motor.
Efficiency 80 %.Consumptions Standby 4W / Average per cycle 50 W.Transmission Geared. PL 600 - 1.829 mm. STD8 belt.
www.fermator.com5 Robusta PM
N
RR
C= =
1938
0
150
14
283
150
150
200
200
254
50325 25796,5
50 x
4
4
90595
50 x n
120120
9510
090
9560
30
6
6
95
+100
-50
254
19
20
= =
180
248
26065 410 210 225
≥ 35
PL
HL
+ 4
00
HL
HL
+ 16
PL
2PL + 100
PL/2 + 30
HL
+ 22
0
HL
+ 22
0
PL/2 PL/2
WW
Panel full open Panel full open
CARFLOOR
Con
cent
ricØ
92
Ecce
ntric
Ø 2
6
H
FIXING BRACKETRANGE
SILL DETAIL
MECHANICAL DETAILS
Technical drawing 2 panel centre parting door
95 mm sill
thickness5
thickness3
Required only with emergency supply.C Total operator length (track length + 50 mm). See page 8.N Recomended vertical fixing point for bracket.R Recomended positions for operator lower fixations.W Panel projection out of the operator with door fully open. See page 8.- If not otherwise indicated all dimensions in mm.
Notes:
www.fermator.com 6Robusta PM
N
RR
196
20
180
C
273
380
1415
0 4
95
95905
619
H
32
60
30
9510
095
95
50650 390
52150
120 120
20
248
≥ 35
+100
-50
283
254
Panel full open
W
50325 25
768,515
0
200
150
200
50 x
4
PL
HL
+ 16
HL
HL
+ 40
0
HL
+ 22
0
PL + 52
2PL + 100
PL
PL650
PL
HL
+ 22
0
Con
cent
ricØ
92
Ecce
ntric
Ø 2
6
CARFLOOR
H
Technical drawing 1 panel side opening door
95 mm sill
thickness5
thickness3
FIXING BRACKETRANGE
MECHANICAL DETAILS
SILL DETAIL
Required only with emergency supply.C Total operator lenght (Track length + 50 mm). See page 8.N Recomended vertical fixing point for bracket.R Recomended positions for operator lower fixations.W Panel projection out of the operator with door fully open. See page 8.- If not otherwise indicated all dimensions in mm.
Notes:
www.fermator.com7 Robusta PM
N
RR
V
T
C
20
380
4
180
19 130
40 80
6
55 125
130
273
619
32
+100
-50
≥ 35
215==
==
50250
130
9010
013
060
30
52
120 12020
248
14254
Panel full open
W
150
283503861,5
25
25
150
200
150
200
50 x
4
PL
1,5PL + 100
HL
+ 16
HL
+ 40
0
HL
HL
+ 22
0
HL
+ 22
0
PL
PL
PL
PL/2 + 39
Con
cent
ricØ
92
Ecce
ntric
Ø 2
6
CARFLOOR
H
Technical drawing 2 panel side opening door
130 mm sill
thickness5
thickness3
FIXING BRACKETRANGE
MECHANICAL DETAILS
SILL DETAIL
Required only with emergency supply. C Total operator lenght (Track lenght + 50 mm). See page 8.N Recomended vertical fixing point for bracket.R Recomended positions for operator lower fixations.T Optional for PL 30 to 48 inches or PL 762 to 1.219 mm.V Only for PL > 36 inches or PL > 914 mm.W Panel projection out of the operator with door fully open. See page 8.- If not otherwise indicated all dimensions in mm.
Notes:
ROBUSTA PM www.fermator.com 8
Total dimension tables
T2PL C WInches mm
- 750 1.218 030 762 031 787
1.2690
- 800 032 813 14,533 838
1.3710
- 850 034 864 035 889
1.4220
- 900 036 914 1337 940
1.5230
- 950 038 965 039 991
1.5740
- 1.000 040 1.016 1441 1.041
1.6760
- 1.050 042 1.067 043 1.092
1.7260
- 1.100 044 1.118 1545 1.143
1.8280
- 1.150 046 1.168 047 1.194
1.8790
- 1.200 048 1.219 13,549 1.245
1.980
0- 1.250 0
50 1.270 051 1.295 26,5- 1.300 34
52 1.321 65,553 1.346
2.133
0- 1.350 0
54 1.372 055 1.397 26,5- 1.400 31
56 1.422 6457 1.448
2.285
0- 1.450 0
58 1.473 059 1.499 27,5- 1.500 29
60 1.524 6561 1.549
2.438
0- 1.550 0
62 1.575 063 1.600 2664 1.626 65- 1.650
2.590
065 1.651 066 1.676 0- 1.700 24
67 1.702 2768 1.727 65- 1.750
2.742
069 1.753 070 1.778 0- 1.800 22
71 1.803 2772 1.829 66
C2PL C WInches mm
- 750
1.676
030 762 031 787 0- 800 24
32 813 5033 838
1.828
0- 850 0
34 864 035 889 50- 900 72
36 9141.980
037 940 0- 950 20
38 965 5039 991
2.1330
- 1.000 040 1.016 041 1.041 49- 1.050
2.285
042 1.067 043 1.092 0- 1.100 15
44 1.118 5145 1.143
2.4380
- 1.150 046 1.168 047 1.194 50- 1.200
2.590
048 1.219 049 1.245 0- 1.250 10
50 1.270 5051 1.295
2.742
0- 1.300 0
52 1.321 053 1.346 50- 1.350 58
54 1.372 10255 1.397 152- 1.400 158
56 1.422 20257 1.448
2.895
101- 1.450 105
58 1.473 15159 1.499 203- 1.500 205
T1PL C WInches mm
- 600 1.218 5924 610 7925 635
1.3710
- 650 626 660 2627 686 78- 700
1.523
028 711 029 737 28- 750 54
30 762 7831 787
1.6760
- 800 132 813 2733 838 77- 850
1.828
034 864 035 889 27- 900 49
36 914 7737 940
1.9800
- 950 038 965 2639 991 44- 1.000
2.133
7840 1.016 041 1.041 0- 1.050 28
42 1.067 7843 1.092
2.2850
- 1.100 044 1.118 2845 1.143 78
Fermator reserves the right to make changes to the specification of the products within this catalogue without prior notice.
General: [email protected]: [email protected] • Brazil: [email protected] • Italy: [email protected] • France: [email protected], [email protected]
China: [email protected] • India: [email protected] • Poland: [email protected] • Germany: [email protected]
Sales contacts