robert e. wolf associate professor - extension specialist application technology
DESCRIPTION
Application Strategies Calibration….Calibration…. Top Farmer Crop Workshop Purdue University July 20, 2009. Robert E. Wolf Associate Professor - Extension Specialist Application Technology. Biological and Agricultural Engineering. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/1.jpg)
Robert E. Wolf
Associate Professor - Extension Specialist Application Technology
Biological and Agricultural Engineering
Application StrategiesCalibration….Calibration….
Top Farmer Crop WorkshopPurdue University
July 20, 2009
![Page 2: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/2.jpg)
Accurate and efficient applications:Increase Efficacy – Minimize Drift
![Page 3: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/3.jpg)
Calibration!!!!
Ensuring that the spray output is what it is supposed to be!
![Page 4: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/4.jpg)
Calibration/Nozzle Selection:
• What is the first step?• Use label to select the
– application volume– product rate
• Choose an appropriate travel speed - MPH
• Effective width of application– nozzle spacing
• Calculate GPM – Flow rate per nozzle
• Select the correct size of nozzle!
![Page 5: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/5.jpg)
Rate Controllers:Rate Controllers:
![Page 6: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/6.jpg)
Parallel Swathing – light bars:
![Page 7: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/7.jpg)
Auto Steering:
![Page 8: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/8.jpg)
Automatic Boom Height Control
![Page 10: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/10.jpg)
![Page 11: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/11.jpg)
Improving Coverage?
![Page 12: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/12.jpg)
Courtesy of Ken Giles, U of California Davis
![Page 13: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/13.jpg)
Calibration!!!!The next phase!
Ensuring that the spray droplet spectrum is what it is supposed to be to maximize
efficacy while minimizing drift!
![Page 14: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/14.jpg)
ASABE S-572 Droplet Size Standard
![Page 15: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/15.jpg)
Spray quality categories.
ASABE Standard S-572.1Category (symbol) Color Code
Extra Fine (XF) Purple
Very Fine (VF) Red
Fine (F) orange
Medium (M) yellow
Coarse (C) Blue
Very Coarse (VC) Green
Extra Course (XC) White
Ultra Coarse (UC) Black
2009
![Page 16: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/16.jpg)
Source: Crop Life – July 2002
>150
151-250
251-350
351-450
451-550
>551
ASABE Standard
![Page 17: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/17.jpg)
![Page 18: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/18.jpg)
Page 4
![Page 19: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/19.jpg)
![Page 20: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/20.jpg)
See Page 182, TeeJet Catalog 50A
![Page 21: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/21.jpg)
Droplet Selection/Calibration:
p. 15
![Page 22: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/22.jpg)
![Page 23: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/23.jpg)
![Page 24: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/24.jpg)
Greenleaf Droplet chart:
![Page 25: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/25.jpg)
![Page 26: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/26.jpg)
![Page 27: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/27.jpg)
![Page 28: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/28.jpg)
![Page 29: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/29.jpg)
What is the ‘Real’ difference ?
……Medium droplet at 225 microns
……Coarse droplet at 300 microns
How much heavier? Or is it???
300 = 1.33
2251.33 bigger
1.333 = 1.33 * 1.33 * 1.33 = 2.35
2.35 * 100 = 235% heavier
![Page 30: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/30.jpg)
Drift Reduction Additives:
• Many available!• Not EPA regulated• Long chain polymers• Soluble powders• 50 - 80% reduction in off-
target movement• Not all will work!!!!• Pump shear problems• Effect on the pattern?
![Page 31: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/31.jpg)
Volume Median Diameter (VMD)
050
100150200250300350400450500
11004XR 11004TT TF 2 11003AI
Mic
rons
Water RWM + 2%AMSRWM + 1% AMS + Array RWM + 2% AMS + BorderRWM + 2% AMS + Placement
40 psi 40 psi 40 psi 70 psi
% less than 210 Microns
37 51 36 35 45 23 30 14 15 26 19 22 14 13 22 10 17 29 29 15
Bob Klein, U of Nebraska
Percent fines
![Page 32: Robert E. Wolf Associate Professor - Extension Specialist Application Technology](https://reader035.vdocuments.us/reader035/viewer/2022062309/56813e03550346895da7de57/html5/thumbnails/32.jpg)
Disclaimer:
• Brand names appearing in this presentation are for identification and illustration purposes only.