Page 1: Road Lighting Simulation

Road Lighting Simulation

Partner for Contact: Order No.: Company: Customer No.:

Date: 16.03.2018Operator:

Page 2: Road Lighting Simulation

Road Lighting Simulation

16.03.2018

OperatorTelephone

Faxe-Mail

Table of contents

Road Lighting SimulationProject Cover 1Table of contents 2Luminaire parts list 3Exterior Scene 1

Planning data 4Luminaires (layout plan) 5Luminaires (coordinates list) 63D Rendering 7False Color Rendering 8Exterior Surfaces

Calculation Grid Of RoadSummary 9Value Chart (E, Perpendicular) 10Table (E, Perpendicular) 11

Page 2

Page 3: Road Lighting Simulation

Road Lighting Simulation

16.03.2018

OperatorTelephone

Faxe-Mail

Road Lighting Simulation / Luminaire parts list

4 Pieces HB02-150 5000K Ra80 90140DEG H28403Article No.: Luminous flux (Luminaire): 20154 lmLuminous flux (Lamps): 20154 lmLuminaire Wattage: 151.3 WLuminaire classification according to CIE: 100CIE flux code: 45 83 98 100 100Fitting: 1 x 5000K Ra80 (Correction Factor 1.000).

See our luminaire catalog for an image of

the luminaire.

Page 3

Page 4: Road Lighting Simulation

Road Lighting Simulation

16.03.2018

OperatorTelephone

Faxe-Mail

Exterior Scene 1 / Planning data

Light loss factor: 0.70, ULR (Upward Light Ratio): 0.0% Scale 1:1259

Luminaire Parts List

No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]

1 4HB02-150 5000K Ra80 90140DEG H28403 (1.000)

20154 20154 151.3

Total: 80615 Total: 80616 605.2

Page 4

Page 5: Road Lighting Simulation

Road Lighting Simulation

16.03.2018

OperatorTelephone

Faxe-Mail

Exterior Scene 1 / Luminaires (layout plan)

Scale 1 : 1259

Luminaire Parts List

No. Pieces Designation

1 4 HB02-150 5000K Ra80 90140DEG H28403

Page 5

Page 6: Road Lighting Simulation

Road Lighting Simulation

16.03.2018

OperatorTelephone

Faxe-Mail

Exterior Scene 1 / Luminaires (coordinates list)

HB02-150 5000K Ra80 90140DEG H2840320154 lm, 151.3 W, 1 x 1 x 5000K Ra80 (Correction Factor 1.000).

No. Position [m] Rotation [°]X Y Z X Y Z

1 40.000 25.000 8.000 0.0 0.0 0.0

2 80.000 25.000 8.000 0.0 0.0 0.0

3 120.000 25.000 8.000 0.0 0.0 0.0

4 160.000 25.000 8.000 0.0 0.0 0.0

Page 6

Page 7: Road Lighting Simulation

Road Lighting Simulation

16.03.2018

OperatorTelephone

Faxe-Mail

Exterior Scene 1 / 3D Rendering

Page 7

Page 8: Road Lighting Simulation

Road Lighting Simulation

16.03.2018

OperatorTelephone

Faxe-Mail

Exterior Scene 1 / False Color Rendering

Page 8

Page 9: Road Lighting Simulation

Road Lighting Simulation

16.03.2018

OperatorTelephone

Faxe-Mail

Exterior Scene 1 / Calculation Grid Of Road / Summary

Scale 1 : 1259Position: (60.028 m, 25.005 m, 0.000 m)Size: (40.000 m, 15.000 m)Rotation: (0.0°, 0.0°, 0.0°)Type: Normal, Grid: 15 x 5 Points

Results overview

Eh m/Em = Relationship between middle horizontal and vertical illuminance, H = Measuring Height

No. Type Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax Eh m/Em H [m] Camera

1 perpendicular 20 3.65 59 0.18 0.06 / 0.000 /

Page 9

Page 10: Road Lighting Simulation

Road Lighting Simulation

16.03.2018

OperatorTelephone

Faxe-Mail

Exterior Scene 1 / Calculation Grid Of Road / Value Chart (E, Perpendicular)

Values in Lux, Scale 1 : 286

Position of surface in external scene:Marked point: (40.028 m, 17.505 m, 0.000 m)

Grid: 15 x 5 Points

Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax

20 3.65 59 0.18 0.06

Page 10

Page 11: Road Lighting Simulation

Road Lighting Simulation

16.03.2018

OperatorTelephone

Faxe-Mail

Exterior Scene 1 / Calculation Grid Of Road / Table (E, Perpendicular)

Position of surface in external scene:Marked point: (40.028 m, 17.505 m, 0.000 m)

13.500 25 23 19 14 9.64 6.43 4.32 3.70 4.35 6.50

10.500 51 41 31 21 14 9.51 6.07 5.04 6.12 9.60

7.500 59 44 33 22 16 10 6.57 5.41 6.63 10

4.500 51 41 31 21 15 9.46 6.01 4.98 6.06 9.55

1.500 25 23 19 14 9.85 6.46 4.28 3.65 4.31 6.53

m 1.333 4.000 6.667 9.333 12.000 14.667 17.333 20.000 22.667 25.333

Attention: The coordinates refer to the image above. Values in Lux.

Grid: 15 x 5 Points

Eav

[lx] Emin

[lx] Emax

[lx] u0 Emin

/ Emax

20 3.65 59 0.18 0.06

Page 11

Page 12: Road Lighting Simulation

Road Lighting Simulation

16.03.2018

OperatorTelephone

Faxe-Mail

Exterior Scene 1 / Calculation Grid Of Road / Table (E, Perpendicular)

Position of surface in external scene:Marked point: (40.028 m, 17.505 m, 0.000 m)

13.500 9.72 14 19 23 25

10.500 15 21 31 41 51

7.500 16 23 33 44 59

4.500 15 21 31 42 51

1.500 9.94 14 19 23 25

m 28.000 30.667 33.333 36.000 38.667

Attention: The coordinates refer to the image above. Values in Lux.

Grid: 15 x 5 Points

Eav

[lx] Emin

[lx] Emax

[lx] u0 Emin

/ Emax

20 3.65 59 0.18 0.06

Page 12