rnl series insertion liquid flow meter · display flow rate and total w/programmable keypad an...
TRANSCRIPT
Vortex Flow Meters
Toll Free: 888-5RACINE
RNL Series Insertion Liquid Flow Meter
racinevortex.com
TM
• Applications Boiler feed water and condensate Cooling tower Pool and water park Chemical processing Municipal water treatment Ground water monitoring Irrigation systems • Pipe sizes 4" (102 mm) and higher• Very low pressure drop
2 Tel: 262-639-6770
Operating Principle
Flow Meter Selection Specifications
Measured Liquids
Velocity Range 2 to 18 FPS (0.6 to 5.5 MPS)
Accuracy ±2% of reading
Repeatability 0.5% of reading
Process Temperature Maximum 300 °F (148 °C)
Ambient Temperature -20 °F to +110 °F (-28 °C to +43 °C)Limits
Operating Pressure -5 to 250 PSIG (-0.3 to 17 BARg)
Input Power 10 to 30 VDC
Signal Output 4-20 mA (two-wire loop)
Enclosure NEMA 4X (IP66) polycarbonate
Maximum Viscosity 10 centistokes - consult factory for higher viscosity
Display Flow rate and total w/programmable keypad
An everyday example of a vortex shedding phenomenon is a flag waving in the breeze: the flag waves due to the vortices shed by wind moving across the flagpole. Within the flow meter, as flowing liquid moves across the strut or “bluff bar”, vortices are also shed but on a smaller scale. The meter transmits an ultrasonic beam through the vortex pattern downstream of the strut. As vortices are shed, the carrier wave of the ultrasonic signal modulates. The modulation of the carrier wave is measurable and proportional to the number of vortices shed. Digital processing enables the vortices to be counted, and this value is converted into a velocity. Software converts velocity into a volumetric flow rate, in units of measure selected by the operator.Racine vortex flow meters utilize the smallest strut in the industry, which allows for high sensitivity; superior performance at low flow rates and low pressure drop.
FLOW
Racine vortex offers a sophisticated software program to aid in the flow meter selection process. The program accounts for system pressure and temperature, as well as media density, viscosity and specific gravity. Select from a complete list of Metric and English engineering units, using default or customized reference standards for pressure and temperature. The software may be downloaded at no charge from racinevortex.com.
Receiving TransducerSmall Strut Shed Vortices
Transmitting Transducer
3Fax: 262-639-2267
Flow Ranges*
Part Number Construction
MAXIMUMMINIMUM MAXIMUMMINIMUMNOMINAL PIPE SIZE
in. (mm)
GPM LPM
*Consult RACINE Flow Meter Selection Software for temperature and pressure conditions other than those listed here, available at racinevortex.com
Based on water at 1 cSt at 73 ºF schedule 40 pipe
78
176
313
490
705
960
1253
1586
1958
4.0 (102)
6.0 (152)
8.0 (203)
10.0 (254)
12.0 (305)
14.0 (356)
16.0 (406)
18.0 (457)
20.0 (508)
705
1586
2820
4406
6344
8635
11279
14275
17623
295
667
1185
1855
2668
3634
4743
6003
7411
2669
6004
10675
16679
24015
32687
42696
54037
66710
Part Number: L SNaa Stem Length 12) 12" Stem 24) 24" Stem 36) 36" Stem 1S) 12" Stem + Stand-off1 2S) 24" Stem + Stand-off1 3S) 36" Stem + Stand-off1
bbb Mounting Style/ Cable Length 150) 2" x 150# Flange2
151) 2" x 150# Flange + 10' cable3
152) 2" x 150# Flange + 25' cable3
153) 2" x 150# Flange + 50' cable3
300) 2" x 300# Flange2
301) 2" x 300# Flange + 10' cable3
302) 2" x 300# Flange + 25' cable3
303) 2" x 300# Flange + 50' cable3
NPT) 2" MNPT Fitting2
NP1) 2" MNPT Fitting + 10' cable3
NP2) 2" MNPT Fitting + 25' cable3
NP3) 2" MNPT Fitting + 50' cable3
D50) DN 50 Flange2,4
D51) DN 50 Flange4 + 10' cable3
D52) DN 50 Flange4 + 25' cable3
D53) DN 50 Flange4 + 50' cable3
Flow Meter MaterialS) 316SS (standard)
d O-ring Material 1) Viton® (standard) 3) Ethylene Propylene
EnclosureD) Digital display of flow rate and total. NEMA 4X (IP66) polycarbonate
1 Additional physical barrier between sensor head and transmitter2 Integral mount transmitter 3 Remote mount transmitter 4 Flange to DIN 2527 specifications
Racine Insertion Liquid StemLength
Mounting Style MeterMaterial
O-ringMaterial
EnclosureApprovals
RNL Series Insertion Flow Meters for Liquid
a a b b b d
ApprovalsN) General Purpose
N D
D
R NL- 0001 09/11
4
Racine is a trademark of Racine Federated Inc.Viton is a registered trademark of DuPont Performance Elastomers.© 2011 Racine Federated Inc., all rights reserved.
Toll Free (US & Canada): 888-5RACINE (572-2463)
TM
Stem Length Selection Procedure
Dimensional DrawingsInches (mm)
8635 Washington Avenue Racine, WI 53406-3738 [email protected]
5.75(146.0)
3.93(99.8)
7.00(177.8)
BFully
Retracted
AStem Length
MeasuringWindow {
Before purchasing a RNL insertion liquid flow meter, it is necessary to calculate the stem length required for a particular piping system. In order to complete this calculation, some knowledge of the piping system must be known. The variables required are:
• ½ Internal pipe diameter A
• Pipe wall thickness B
• Length of the valve stack C
Using this information and referring to the picture below,a minimum stem length can be determined.
Minimum Stem Length Required = A + B + C
RNL36 36.0 (914) 44.6 (1133)
RNL24 24.0 (610) 32.6 (828)
RNL12 12.0 (305) 20.6 (523)
Model Dim. A Dim. B
Insertion hardware kits available withflanged or NPT connections.
2" Weld-O-Let
6" PipeNipple
MeasuringWindow{
CValve Stack
2" Full PortBall Valve
2" Flange
BPipe Wall
¼" PressureSensor Port
A½ Internal
Pipe Diameter