rn design ltd for constructionpreliminary-not

5
L C F S UP DN F S L C UP DN L C DN L C F S UP DN DN 4R MAX L C DN L C F S UP DN DN 4R MAX L C DN L C DN L C L C DN L C L C DN UP DN 4R MAX F S L C L C DN L C L C UP DN DN 4R MAX F S L C L C F S UP DN 3R MIN DN DN L C L C DN L C L C F S DN UP DN DN 3R MIN L C L C DN DN 4R MAX BREAKFAST 7'-8" X 10'-3" KITCHEN 7'-8" X 11'-0" GARAGE 9'-10" X 20'-0" GREAT ROOM 10'-8" X 18'-5" DN 4R MAX BREAKFAST 7'-8" X 10'-3" KITCHEN 7'-8" X 11'-0" GARAGE 9'-10" X 20'-0" GREAT ROOM 12'-8" X 18'-5" BEDROOM 2 9'-6" X 10'-0" BEDROOM 3 9'-0" X 10'-0" MASTER BEDROOM 15'-0" X 13'-9" BREAKFAST 7'-8" X 10'-3" KITCHEN 7'-8" X 11'-0" GARAGE 9'-10" X 20'-0" GREAT ROOM 10'-8" X 18'-5" BEDROOM 2 9'-6" X 9'-3" BEDROOM 3 9'-0" (9'-0") X 10'-0" MASTER BEDROOM 13'-0" X 14'-8" BREAKFAST 7'-8" X 10'-3" KITCHEN 7'-8" X 11'-0" GARAGE 9'-10" X 20'-0" GREAT ROOM 10'-8" X 18'-5" MASTER BEDROOM 13'-0" X 14'-8" BEDROOM 2 9'-6" X 10'-0" BEDROOM 3 9'-0" (8'-4") X 10'-0" MASTER BEDROOM 13'-0" X 14'-8" BEDROOM 2 9'-6" X 10'-0" BEDROOM 3 9'-0" X 10'-0" MASTER BEDROOM 13'-4" X 14'-8" BEDROOM 2 9'-6" X 11'-0" BEDROOM 3 9'-0" X 10'-0" GARAGE 9'-10" X 20'-0" BREAKFAST 7'-8" X 10'-3" KITCHEN 7'-8" X 11'-0" GREAT ROOM 10'-8" X 18'-5" MASTER BEDROOM 13'-4" X 14'-8" BEDROOM 2 9'-6" X 11'-0" BEDROOM 3 9'-0" X 10'-0" GARAGE 9'-10" X 20'-0" BREAKFAST 7'-8" X 10'-3" KITCHEN 7'-8" X 11'-0" GREAT ROOM 10'-8" X 18'-5" GARAGE 9'-10" X 20'-0" KITCHEN 8'-10" X 13'-6" GREAT ROOM 10'-0" X 21'-10" MASTER BEDROOM 13'-0" X 13'-6" BEDROOM 3 8'-10" X 9'-0" BEDROOM 2 9'-8" X 10'-0" GARAGE 9'-10" X 20'-0" KITCHEN 8'-10" X 13'-6" GREAT ROOM 10'-0" X 21'-10" MASTER BEDROOM 13'-0" X 13'-6" BEDROOM 3 8'-10" X 9'-0" BEDROOM 2 9'-8" X 10'-0" GAS METER HYDRO METER D W D W GAS METER HYDRO METER D W D W D W HYDRO METER GAS METER D W GAS METER HYDRO METER HYDRO METER GAS METER D W HYDRO METER GAS METER D W DW DW DW DW DW DW DW DW 5'-8" 43'-5" 20'-2" 5'-8" 22'-2" 43'-5" 21'-10" 5'-8" 21'-2" 43'-5" 20'-2" 5'-8" 43'-5" 20'-2" 20'-2" 19'-10" 19'-8" 5'-8" 43'-5" 19'-8" 5'-8" 43'-5" 19'-8" 35'-11" 9'-8" 45'-7" 19'-8" 19'-8" 35'-11" 9'-8" 19'-8" GROUND FLOOR ELEV 'A' SECOND FLOOR ELEV 'A' GROUND FLOOR ELEV 'B' SECOND FLOOR ELEV 'B' GROUND FLOOR ELEV 'A' SECOND FLOOR ELEV 'A' GROUND FLOOR ELEV 'B' SECOND FLOOR ELEV 'B' SECOND FLOOR -END COND. ELEV 'A' GROUND FLOOR -END COND. ELEV 'A' GROUND FLOOR -END COND. ELEV 'B' SECOND FLOOR -END COND. ELEV 'B' GROUND FLOOR - UPGRADED END COND. ELEV 'A' SECOND FLOOR - UPGRADED END COND. ELEV 'A' GROUND FLOOR - UPGRADED END COND. ELEV 'B' SECOND FLOOR - UPGRADED END COND. ELEV 'B' TH-1 TH-2 TH-2 END CONDITION TH-2 UPGRADED END CONDITION FLUSH BREAKFAST BAR OPT GAS FIREPLACE 6'0" SLIDING DOOR FLOOR ABOVE DOOR WHERE GRADE PERMITS PWD FOYER (SUNKEN IF REQ'D) (SUNKEN IF REQ'D) OPEN TO ABOVE COVERED PORCH (IF REQ'D) HALF WALL FLUSH BREAKFAST BAR 6'0" SLIDING DOOR FLOOR ABOVE FOYER PWD (SUNKEN IF REQ'D) DOOR WHERE GRADE PERMITS (SUNKEN IF REQ'D) OPEN TO ABOVE COVERED PORCH (IF REQ'D) HALF WALL BATH OPT UPPERS LINEN LAUNDRY WIC WIC ENSUITE 62"X32 GLASS SHOWER OPEN TO BELOW RAILING CATHEDRAL CEILING FLUSH BREAKFAST BAR PORTICO 6'0" SLIDING DOOR FLOOR ABOVE O.T.A. FOYER PWD (SUNKEN IF REQ'D) DOOR WHERE GRADE PERMITS (SUNKEN IF REQ'D) OPEN TO ABOVE LEDGE (IF REQ'D) BATH OPT UPPERS LINEN LAUNDRY WIC WIC ENSUITE OPEN TO BELOW 62"X32 GLASS SHOWER OPEN TO BELOW RAILING CATHEDRAL CEILING CATHEDRAL CEILING FLUSH BREAKFAST BAR OPT GAS FIREPLACE PORTICO 6'0" SLIDING DOOR FLOOR ABOVE DOOR WHERE GRADE PERMITS PWD FOYER (SUNKEN IF REQ'D) (SUNKEN IF REQ'D) OPEN TO ABOVE (IF REQ'D) ENSUITE WIC BATH OPT UPPERS LINEN LAUNDRY 62"X32 GLASS SHOWER OPEN TO BELOW RAILING CATHEDRAL CEILING ENSUITE WIC BATH OPT UPPERS LINEN LAUNDRY OPEN TO BELOW RAILING 62"X32 GLASS SHOWER CATHEDRAL CEILING ENSUITE BATH WIC OPT UPPERS LINEN LAUNDRY OPEN TO BELOW RAILING CATHEDRAL CEILING 62"X32 GLASS SHOWER PORTICO FLOOR ABOVE PWD FOYER (SUNKEN IF REQ'D) (SUNKEN IF REQ'D) OPEN TO ABOVE DOOR WHERE GRADE PERMITS (IF REQ'D) FLUSH BREAKFAST BAR 6'0" SLIDING DOOR HALF WALL ENSUITE BATH WIC OPEN TO BELOW RAILING OPT UPPERS LINEN LAUNDRY 62"X32 GLASS SHOWER CATHEDRAL CEILING PWD FOYER COVERED PORCH DOOR WHERE GRADE PERMITS 6'0" SLIDING DOOR FLOOR ABOVE (IF REQ'D) (SUNKEN IF REQ'D) (SUNKEN IF REQ'D) OPEN TO ABOVE FLUSH BREAKFAST BAR HALF WALL FOYER PWD DOOR WHERE GRADE PERMITS COVERED PORCH FLOOR ABOVE FLUSH BREAKFAST BAR GARDEN DOOR COFFERED CEILING (IF REQ'D) (SUNKEN IF REQ'D) ADDITIONAL STEPS AS REQ'D (SUNKEN IF REQ'D) HALF WALL WIC BATH ENSUITE LINEN LAUNDRY OPT UPPERS RAILING DOOR WHERE GRADE PERMITS PORTICO FLOOR ABOVE FLUSH BREAKFAST BAR GARDEN DOOR (IF REQ'D) ADDITIONAL STEPS AS REQ'D COFFERED CEILING FOYER PWD (SUNKEN IF REQ'D) (SUNKEN IF REQ'D) HALF WALL WIC LINEN LAUNDRY OPT UPPERS RAILING BATH ENSUITE OPT GAS FIREPLACE A1 scale project # project page revisions date dwn chk # client model File:C:\_RN_Standards\temp\AcPublish_4264\17047-TH-BLOCK-HL.dwg Plotted: Oct 18, 2017 By:paulah 1/8" = 1'-0" 17047 Grand Valley, Town of Hollenbeck Cachet Estate Homes Inc. TH-BLOCK SIGNATURE: I, DECLARE THAT I HAVE REVIEWED AND TAKEN DESIGN RESPONSIBILITY FOR THE DESIGN WORK ON BEHALF OF RN DESIGN LTD ,UNDER DIVISION C,PART-3 SUBSECTION-3.2.4 OF THE BUILDING CODE. I AM QUALIFIED AND THE FIRM IS REGISTERED IN THE APPROPRIATE CLASSES / CATEGORIES. QUALIFIED DESIGNER BCIN: FIRM BCIN: DATE: PRELIMINARY-NOT FOR CONSTRUCTION ISSUED FOR SPA 19-OCT-17 PH MSA 1

Upload: others

Post on 28-Dec-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RN DESIGN LTD FOR CONSTRUCTIONPRELIMINARY-NOT

L

C

F

S

UP

DN F

S

L

C

UP

DN

L

C

DN

L

C

F

S

UP

DN

DN 4R MAX

L

C

DN

L

C

F

S

UP

DN

DN 4R MAX

L

C

DN

L

C

DN

L

C

L

C

DN

L

C

L

C

DN

UP

DN 4R MAX

F

S

L

C

L

C

DN

L

C

L

C

UP

DN

DN 4R MAX

F

S

L

C

L

C

F

S

UP

DN3R

MIN

DN

DN

L

C

L

C

DN

L

C

L

C

F

S

DN

UP

DN

DN3R

MIN

L

C

L

C

DN

DN 4R MAX

BREAKFAST 7'-8" X 10'-3"

KITCHEN 7'-8" X 11'-0"

GARAGE 9'-10" X 20'-0"

GREAT ROOM 10'-8" X 18'-5"

DN 4R MAX

BREAKFAST 7'-8" X 10'-3"

KITCHEN 7'-8" X 11'-0"

GARAGE 9'-10" X 20'-0"

GREAT ROOM 12'-8" X 18'-5"

BEDROOM 2 9'-6" X 10'-0"

BEDROOM 3 9'-0" X 10'-0"

MASTER BEDROOM 15'-0" X 13'-9"

BREAKFAST 7'-8" X 10'-3"

KITCHEN 7'-8" X 11'-0"

GARAGE 9'-10" X 20'-0"

GREAT ROOM 10'-8" X 18'-5"

BEDROOM 2 9'-6" X 9'-3"

BEDROOM 3 9'-0" (9'-0") X 10'-0"

MASTER BEDROOM 13'-0" X 14'-8"

BREAKFAST 7'-8" X 10'-3"

KITCHEN 7'-8" X 11'-0"

GARAGE 9'-10" X 20'-0"

GREAT ROOM 10'-8" X 18'-5" MASTER BEDROOM

13'-0" X 14'-8"

BEDROOM 2 9'-6" X 10'-0"

BEDROOM 3 9'-0"(8'-4") X 10'-0"

MASTER BEDROOM 13'-0" X 14'-8"

BEDROOM 2 9'-6" X 10'-0"

BEDROOM 3 9'-0" X 10'-0"

MASTER BEDROOM 13'-4" X 14'-8"

BEDROOM 2 9'-6" X 11'-0"

BEDROOM 3 9'-0" X 10'-0"

GARAGE 9'-10" X 20'-0"

BREAKFAST 7'-8" X 10'-3"

KITCHEN 7'-8" X 11'-0"

GREAT ROOM 10'-8" X 18'-5" MASTER BEDROOM

13'-4" X 14'-8"

BEDROOM 2 9'-6" X 11'-0"

BEDROOM 3 9'-0" X 10'-0"

GARAGE 9'-10" X 20'-0"

BREAKFAST 7'-8" X 10'-3"

KITCHEN 7'-8" X 11'-0"

GREAT ROOM 10'-8" X 18'-5"

GARAGE 9'-10" X 20'-0"

KITCHEN 8'-10" X 13'-6"

GREAT ROOM 10'-0" X 21'-10"

MASTER BEDROOM 13'-0" X 13'-6"

BEDROOM 3 8'-10" X 9'-0"

BEDROOM 2 9'-8" X 10'-0"

GARAGE 9'-10" X 20'-0"

KITCHEN 8'-10" X 13'-6"

GREAT ROOM 10'-0" X 21'-10"

MASTER BEDROOM 13'-0" X 13'-6"

BEDROOM 3 8'-10" X 9'-0"

BEDROOM 2 9'-8" X 10'-0"

GAS

MET

ERHY

DRO

MET

ER

D

W

D

W

GAS

MET

ERHY

DRO

MET

ER

D

W

D

W

D

W

HYDRO METER

GAS METER

D

W

GAS METER

HYDRO METER

HYDR

O M

ETER

GAS

MET

ER

DW

HYDR

O M

ETER

GAS

MET

ER

DW

DW DW DWDW

DWDW

DW DW

5'-8"

43'-5

"

20'-2"

5'-8"

22'-2"

43'-5

"

21'-10"

5'-8"

21'-2"

43'-5

"

20'-2"

5'-8"

43'-5

"

20'-2" 20'-2"19'-10"

19'-8"

5'-8"

43'-5

"

19'-8"

5'-8"

43'-5

"

19'-8"

35'-1

1"9'-

8"45

'-7"

19'-8" 19'-8"

35'-1

1"9'-

8"

19'-8"

GROUND FLOOR ELEV 'A' SECOND FLOOR ELEV 'A' GROUND FLOOR ELEV 'B' SECOND FLOOR ELEV 'B'

GROUND FLOOR ELEV 'A' SECOND FLOOR ELEV 'A' GROUND FLOOR ELEV 'B' SECOND FLOOR ELEV 'B'

SECOND FLOOR -END COND. ELEV 'A'GROUND FLOOR -END COND. ELEV 'A' GROUND FLOOR -END COND. ELEV 'B' SECOND FLOOR -END COND. ELEV 'B'GROUND FLOOR -UPGRADED END COND. ELEV 'A'

SECOND FLOOR -UPGRADED END COND. ELEV 'A'

GROUND FLOOR -UPGRADED END COND. ELEV 'B'

SECOND FLOOR -UPGRADED END COND. ELEV 'B'

TH-1

TH-2

TH-2 END CONDITION TH-2 UPGRADED END CONDITION

FLUSH BREAKFAST BAR

OPT

GAS

FIR

EPLA

CE

6'0" SLIDING DOOR

FLOOR ABOVE

DOO

R W

HERE

GRA

DE P

ERM

ITS

PWD FOYER(SUNKENIF REQ'D)

(SUNKENIF REQ'D)

OPE

N TO

ABO

VE

COVEREDPORCH

(IF REQ'D)

HALF

WAL

L

FLUSH BREAKFAST BAR

6'0" SLIDING DOOR

FLOOR ABOVEFOYER

PWD

(SUNKENIF REQ'D)

DOO

R W

HERE

GRA

DE P

ERM

ITS(SUNKENIF REQ'D)

OPE

N TO

ABO

VE

COVEREDPORCH

(IF REQ'D)

HALF

WAL

L

BATH

OPT

UPP

ERSLINEN LAUNDRY

WIC

WIC

ENSUITE

62"X32GLASS SHOWER

OPE

N TO

BEL

OW

RAILI

NG

CATHEDRALCEILING

FLUSH BREAKFAST BAR

PORTICO

6'0" SLIDING DOOR

FLOOR ABOVE

O.T.

A.

FOYERPWD

(SUNKENIF REQ'D)

DOO

R W

HERE

GRA

DE P

ERM

ITS(SUNKENIF REQ'D)

OPE

N TO

ABO

VE

LEDG

E

(IF REQ'D)

BATH

OPT

UPP

ERSLINEN LAUNDRY

WIC

WIC

ENSUITE

OPE

N TO

BEL

OW

62"X32GLASS SHOWER

OPE

N TO

BEL

OW

RAILI

NG

CAT

HEDR

ALC

EILIN

G

CATHEDRALCEILING

FLUSH BREAKFAST BAR

OPT

GAS

FIR

EPLA

CE

PORTICO

6'0" SLIDING DOOR

FLOOR ABOVE

DOO

R W

HERE

GRA

DE P

ERM

ITS

PWD FOYER(SUNKENIF REQ'D)

(SUNKENIF REQ'D)

OPE

N TO

ABO

VE

(IF REQ'D)

ENSUITE

WIC

BATH

OPT

UPP

ERSLINEN LAUNDRY

62"X32GLASS SHOWER

OPE

N TO

BEL

OW

RAILI

NG

CATHEDRALCEILING

ENSUITE

WIC

BATH

OPT

UPP

ERSLINEN LAUNDRY

OPE

N TO

BEL

OW

RAILI

NG

62"X32GLASS SHOWER

CATHEDRALCEILING

ENSUITE

BATH

WIC

OPT

UPP

ERSLINEN LAUNDRY

OPE

N TO

BEL

OW

RAILI

NG

CATHEDRAL CEILING

62"X32GLASS SHOWER

PORTICO

FLOOR ABOVE

PWD FOYER(SUNKENIF REQ'D)

(SUNKENIF REQ'D)

OPE

N TO

ABO

VE

DOO

R W

HERE

GRA

DE P

ERM

ITS

(IF REQ'D)

FLUSH BREAKFAST BAR

6'0" SLIDING DOOR

HALF

WAL

L

ENSUITE

BATH

WIC

OPE

N TO

BEL

OW

RAILI

NG

OPT

UPP

ERSLINEN LAUNDRY

62"X32GLASS SHOWER

CATHEDRAL CEILING

PWD FOYER

COVEREDPORCH

DOO

R W

HERE

GRA

DE P

ERM

ITS

6'0" SLIDING DOOR

FLOOR ABOVE

(IF REQ'D)

(SUNKENIF REQ'D)

(SUNKENIF REQ'D)

OPE

N TO

ABO

VE

FLUSH BREAKFAST BAR

HALF

WAL

L

FOYER

PWD

DOOR WHEREGRADE PERMITS

COVEREDPORCH FLOOR ABOVE

FLUS

H BR

EAKF

AST B

AR

GARDENDOOR

COFFERED CEILING

(IF REQ'D)

(SUNKENIF REQ'D)

ADDI

TIONA

LST

EPS

AS R

EQ'D

(SUNKENIF REQ'D)

HALF

WAL

L

WIC

BATH

ENSUITE

LINEN

LAUNDRY

OPT UPPERS

RAILI

NG

DOOR WHEREGRADE PERMITS

PORTICOFLOOR ABOVE

FLUS

H BR

EAKF

AST B

AR

GARDENDOOR

(IF REQ'D)

ADDI

TIONA

LST

EPS

AS R

EQ'D

COFFERED CEILING

FOYER

PWD

(SUNKENIF REQ'D)

(SUNKENIF REQ'D)

HALF

WAL

L

WIC

LINEN

LAUNDRY

OPT UPPERS

RAILI

NGBATH

ENSUITE

OPT

GAS

FIR

EPLA

CE

A1scale

project #

project

page

revisions date dwn chk#

client

model

File:

C:\

_RN_

Stan

dard

s\te

mp\

AcPu

blish

_426

4\17

047-

TH-B

LOC

K-HL

.dw

g Pl

otte

d: O

ct 1

8, 2

017

By:p

aula

h

1/8" = 1'-0"

17047

Grand Valley,Town of

Hollenbeck

Cachet EstateHomes Inc.

TH-BLOCK

SIGNATURE:

I, DECLARE THAT I HAVE REVIEWED AND TAKENDESIGN RESPONSIBILITY FOR THE DESIGN WORK ON BEHALFOF RN DESIGN LTD,UNDER DIVISION C,PART-3 SUBSECTION-3.2.4OF THE BUILDING CODE. I AM QUALIFIED AND THE FIRM ISREGISTERED IN THE APPROPRIATE CLASSES / CATEGORIES.

QUALIFIED DESIGNER BCIN:FIRM BCIN:DATE:

PRELIMINARY-NOT

FOR CONSTRUCTION

ISSUED FOR SPA 19-OCT-17 PH MSA1

Page 2: RN DESIGN LTD FOR CONSTRUCTIONPRELIMINARY-NOT

A B C D E

FG. FG. FG.FG.

PEAK HEIGHT OF ROOF

MID POINT OF ROOF 24'-4"

30'-7"

8'-1"

10'-0

"8'-

8"1'-

8"6'-

10"

6'-10

"7'-

4"

8'-1"

10'-0

"8'-

8"1'-

8"6'-

10"

6'-10

"7'-

4"

6:12

6:12

12:12

6:12

12:12

UPGRADED END CONDITIONTH-2 - ELEV. 'B' (STD)1

12:12

6:126:12

12:12 12:12

TH-2 - ELEV. 'B' (REV)2

FRONT ELEVATION - BLOCK 1TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

TOP OF TRANSOM

TOP OF DOOR/WIN

SUNKEN FOYERFINISHED GRADE

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

TOP OF TRANSOM

TOP OF DOOR/WIN

SUNKEN FOYER

FINISHED GRADE

TH-1 - ELEV. 'B' (STD)3 TH-2 - ELEV. 'B' (STD)5TH-1 - ELEV. 'B' (REV)4 INTERIOR END CONDITIONTH-2 - ELEV. 'B' (REV)6

ABCDE

FG.

8'-1"

10'-0

"8'-

8"6'-

10"

6'-10

"6'-

10"

8'-1"

10'-0

"8'-

8"6'-

10"

6'-10

"

6:12 6:126:12

12:12

12:12

6:126:126:12 6:12

12:12

UPGRADED END CONDITIONTH-2 - ELEV. 'B' (STD)1TH-2 - ELEV. 'B' (REV)2TH-1 - ELEV. 'B' (STD)3TH-2 - ELEV. 'B' (STD)5 TH-1 - ELEV. 'B' (REV)4INTERIOR END CONDITION

TH-2 - ELEV. 'B' (REV)6

REAR ELEVATION - BLOCK 1

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

FINISHED GRADE

TOP OF WINDOW

TOP OF WINDOW

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

FINISHED GRADE

TOP OF WINDOW

TOP OF WINDOW

FG.

FG. FG.

8'-1"

10'-0

"8'-

8"1'-

0"6'-

10"

7'-4"

8'-1"

10'-0

"8'-

8"1'-

0"6'-

10"

6:12

12:12

12:12

INTERIOR END CONDITIONTH-2 - ELEV. 'B' (REV)6

RIGHT SIDE ELEVATION - BLOCK 1

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF TRANSOMTOP OF WINDOW

SUNKEN FOYERFINISHED GRADE

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF TRANSOM

FINISHED GRADE

TOP OF WINDOWFG.

FG.FG.

FG.

8'-1"

10'-0

"8'-

8"1'-

0"6'-

10"

6'-7"

7'-4"

8'-1"

10'-0

"8'-

8"1'-

0"6'-

10"

6'-10

"

1'-0"

12:12

6:1212:12

UPGRADED END CONDITIONTH-2 - ELEV. 'B' (STD)1

LEFT SIDE ELEVATION - BLOCK 1

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

TOP OF TRANSOMTOP OF WINDOW

SUNKEN FOYERFINISHED GRADE

12:12

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

TOP OF TRANSOM

FINISHED GRADE

TOP OF WINDOW

TOP OF TRANSOM

A2scale

project #

project

page

revisions date dwn chk#

client

model

File:

C:\

_RN_

Stan

dard

s\te

mp\

AcPu

blish

_426

4\17

047-

TH-B

LOC

K-HL

.dw

g Pl

otte

d: O

ct 1

8, 2

017

By:p

aula

h

1/8" = 1'-0"

17047

Grand Valley,Town of

Hollenbeck

Cachet EstateHomes Inc.

TH-BLOCK

SIGNATURE:

I, MARTHA SANDOVAL DECLARE THAT I HAVE REVIEWED ANDTAKEN DESIGN RESPONSIBILITY FOR THE DESIGN WORK ONBEHALF OF RN DESIGN LTD,UNDER DIVISION C,PART-3SUBSECTION-3.2.4 OF THE BUILDING CODE. I AM QUALIFIEDAND THE FIRM IS REGISTERED IN THE APPROPRIATE CLASSES /CATEGORIES.QUALIFIED DESIGNER BCIN: 103017FIRM BCIN: 26995DATE:

ISSUED FOR SPA 19-OCT-17 PH MSA1

Page 3: RN DESIGN LTD FOR CONSTRUCTIONPRELIMINARY-NOT

A B C D EPEAK HEIGHT OF ROOF

MID POINT OF ROOF 25'-2"

32'-2"

FRONT ELEVATION - BLOCK 2INTERIOR END CONDITIONTH-2 - ELEV. 'A' (STD)7 TH-2 - ELEV. 'A' (REV)8 TH-1 - ELEV. 'A' (STD)9 TH-2 - ELEV. 'A' (STD)11TH-1 - ELEV. 'A' (REV)10 UPGRADED END CONDITION

TH-2 - ELEV. 'A' (REV)12

8'-1"

10'-0

"8'-

8"1'-

8"6'-

10"

6'-10

"6'-

8"

8'-1"

10'-0

"8'-

8"1'-

8"6'-

10"

6'-10

"6'-

1"

4:12

6:12

14:12

6:12

6:126:12

6:12

4:12 4:12 4:12

6:12

14:12

14:12

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

TOP OF TRANSOM

TOP OF DOOR/WIN

SUNKEN FOYERFINISHED GRADE

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

TOP OF TRANSOM

TOP OF DOOR/WIN

SUNKEN FOYERFINISHED GRADE

ABCDE

FG.

REAR ELEVATION - BLOCK 2INTERIOR END CONDITIONTH-2 - ELEV. 'A' (STD)7TH-2 - ELEV. 'A' (REV)8TH-1 - ELEV. 'A' (STD)9TH-2 - ELEV. 'A' (STD)11 TH-1 - ELEV. 'A' (REV)10UPGRADED END CONDITION

TH-2 - ELEV. 'A' (REV)12

8'-1"

10'-0

"8'-

8"6'-

10"

6'-10

"6'-

10"

8'-1"

10'-0

"8'-

8"6'-

10"

6'-10

"

6:126:128:12

6:12

14:12 14:12

14:12

6:12 6:12

14:126:126:12

6:126:12

14:12

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

FINISHED GRADE

TOP OF WINDOW

TOP OF WINDOW

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

FINISHED GRADE

TOP OF WINDOW

TOP OF WINDOW

FG.

FG.FG.

INTERIOR END CONDITIONTH-2 - ELEV. 'A' (STD)7

LEFT SIDE ELEVATION - BLOCK 2

8'-1"

10'-0

"8'-

8"1'-

0"6'-

10"

6'-1"

8'-1"

10'-0

"8'-

8"1'-

0"6'-

10"

6:12

14:12

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF TRANSOMTOP OF WINDOW

SUNKEN FOYER

FINISHED GRADE

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF TRANSOM

FINISHED GRADE

TOP OF WINDOW

6:12

4:12

FG. FG.

FG.

UPGRADED END CONDITIONTH-2 - ELEV. 'A' (REV)12

RIGHT SIDE ELEVATION - BLOCK 2

8'-1"

10'-0

"8'-

8"1'-

0"6'-

10"

6'-10

"

8'-1"

10'-0

"8'-

8"

1'-0"

6'-10

"6'-

7"6'-

8"1'-

0"

6:12

14:12

14:12

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

TOP OF TRANSOM

FINISHED GRADE

TOP OF WINDOW

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

TOP OF TRANSOMTOP OF WINDOW

SUNKEN FOYERFINISHED GRADE

TOP OF TRANSOM

A3scale

project #

project

page

revisions date dwn chk#

client

model

File:

C:\

_RN_

Stan

dard

s\te

mp\

AcPu

blish

_426

4\17

047-

TH-B

LOC

K-HL

.dw

g Pl

otte

d: O

ct 1

8, 2

017

By:p

aula

h

1/8" = 1'-0"

17047

Grand Valley,Town of

Hollenbeck

Cachet EstateHomes Inc.

TH-BLOCK

SIGNATURE:

I, DECLARE THAT I HAVE REVIEWED AND TAKENDESIGN RESPONSIBILITY FOR THE DESIGN WORK ON BEHALFOF RN DESIGN LTD,UNDER DIVISION C,PART-3 SUBSECTION-3.2.4OF THE BUILDING CODE. I AM QUALIFIED AND THE FIRM ISREGISTERED IN THE APPROPRIATE CLASSES / CATEGORIES.

QUALIFIED DESIGNER BCIN:FIRM BCIN:DATE:

PRELIMINARY-NOT

FOR CONSTRUCTION

ISSUED FOR SPA 19-OCT-17 PH MSA1

Page 4: RN DESIGN LTD FOR CONSTRUCTIONPRELIMINARY-NOT

A B C D E

FG.FG.FG. FG.

PEAK HEIGHT OF ROOF

MID POINT OF ROOF 24'-4"

30'-7"

8'-1"

10'-0

"8'-

8"

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

6'-10

"

TOP OF WINDOW

FRONT ELEVATION -BLOCK 3UPGRADED END CONDITIONTH-2 - ELEV. 'B' (STD)6TH-2 - ELEV. 'B' (REV)2 TH-1 - ELEV. 'B' (STD)3

TH-2 - ELEV. 'B' (STD)5TH-1 - ELEV. 'B' (REV)4INTERIOR END CONDITIONTH-2 - ELEV. 'B' (REV)1

1'-6"

6'-10

"5'-

5"

8'-1"

10'-0

"8'-

8"1'-

8"6'-

10"

6'-10

"5'-

5"

6:12

6:12

12:12

6:12

12:12

12:12

6:12 6:12

12:12

12:12

SUNKEN FOYERFINISHED GRADE

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

TOP OF TRANSOM

TOP OF DOOR/WIN

SUNKEN FOYER

TOP OF TRANSOM

TOP OF DOOR/WIN

ABCDEPEAK HEIGHT OF ROOF

MID POINT OF ROOF 24'-2"

30'-3"

8'-1"

10'-0

"8'-

8"

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

1'6'-

10"

TOP OF TRANSOMTOP OF DOOR/WIN

6'-10

"

TOP OF WINDOW

REAR ELEVATION -BLOCK 3

UPGRADED END CONDITIONTH-2 - ELEV. 'B' (STD)6 TH-2 - ELEV. 'B' (STD)5 TH-1 - ELEV. 'B' (REV)4 TH-1 - ELEV. 'B' (STD)3 TH-2 - ELEV. 'B' (REV)2 INTERIOR END CONDITION

TH-2 - ELEV. 'B' (REV)1

8'-1"

10'-0

"8'-

8"6'-

10"

6'-10

"

6:126:12 6:12

6:12

12:12

12:1212:12

6:12

12:12

6:12

TOP OF WINDOW

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

TOP OF WINDOW

TOP OF WINDOWFINISHED GRADE

FG.

FG.FG.

8'-1"

10'-0

"8'-

8"

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

6'-10

"

TOP OF WINDOW

LEFT SIDE ELEVATION - BLOCK 3INTERIOR END CONDITIONTH-2 - ELEV. 'B' (REV)1

1'6'-

10"

5'-5"

8'-1"

10'-0

"8'-

8"6'-

10"

1'-0"

6:12

12:12

12:12

SUNKEN FOYERFINISHED GRADE

TOP OF TRANSOMTOP OF WINDOW

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOWTOP OF TRANSOMS

FINISHED GRADE

FG.

FG. FG.

FG.

8'-1"

10'-0

"8'-

8"

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

1'6'-

10"

TOP OF TRANSOMTOP OF DOOR/WIN

6'-10

"

TOP OF WINDOW

RIGHT SIDE ELEVATION -BLOCK 3UPGRADED END CONDITIONTH-2 - ELEV. 'B' (STD)6

8'-1"

10'-0

"8'-

8"

6'-10

"5'-

5"6'-

7"1'-

0"1'-

0"

12:12

6:12

12:12

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

SUNKEN FOYER

TOP OF TRANSOMTOP OF WINDOW

FINISHED GRADE

TOP OF WINDOWTOP OF TRANSOM

A4scale

project #

project

page

revisions date dwn chk#

client

model

File:

C:\

_RN_

Stan

dard

s\te

mp\

AcPu

blish

_426

4\17

047-

TH-B

LOC

K-HL

.dw

g Pl

otte

d: O

ct 1

8, 2

017

By:p

aula

h

1/8" = 1'-0"

17047

Grand Valley,Town of

Hollenbeck

Cachet EstateHomes Inc.

TH-BLOCK

SIGNATURE:

I, DECLARE THAT I HAVE REVIEWED AND TAKENDESIGN RESPONSIBILITY FOR THE DESIGN WORK ON BEHALFOF RN DESIGN LTD,UNDER DIVISION C,PART-3 SUBSECTION-3.2.4OF THE BUILDING CODE. I AM QUALIFIED AND THE FIRM ISREGISTERED IN THE APPROPRIATE CLASSES / CATEGORIES.

QUALIFIED DESIGNER BCIN:FIRM BCIN:DATE:

PRELIMINARY-NOT

FOR CONSTRUCTION

ISSUED FOR SPA 19-OCT-17 PH MSA1

Page 5: RN DESIGN LTD FOR CONSTRUCTIONPRELIMINARY-NOT

A B C D E

PEAK HEIGHT OF ROOF

MID POINT OF ROOF 25'-2"

32'-2"

6'-10

"

TOP OF WINDOW

8'-1"

10'-0

"8'-

8"

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

FRONT ELEVATION- BLOCK 4

TH-2 - ELEV. 'A' (REV)8 TH-1 - ELEV. 'A' (STD)9 TH-2 - ELEV. 'A' (STD)11TH-1 - ELEV. 'A' (REV)10 UPGRADED END CONDITIONTH-2 - ELEV. 'A' (REV)12UPGRADED END CONDITION

TH-2 - ELEV. 'A' (REV)7

1'-8"

6'-10

"5'-

5"

8'-1"

10'-0

"8'-

8"1'-

8"6'-

10"

6'-10

"6'-

1"

6:12

6:126:12

6:12

4:12 4:12 4:12

6:12

18:12

14:12

14:12

4:12

6:12

TOP OF TRANSOM

TOP OF DOOR/WIN

SUNKEN FOYERFINISHED GRADE

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

TOP OF TRANSOM

TOP OF DOOR/WIN

SUNKEN FOYERFINISHED GRADE

ABCDEPEAK HEIGHT OF ROOF

MID POINT OF ROOF 25'-2"

32'-2"

6'-10

"

TOP OF DOOR/WIN

6'-10

"

TOP OF WINDOW

8'-1"

10'-0

"8'-

8"

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

REAR ELEVATION - BLOCK 4UPGRADED END CONDITIONTH-2 - ELEV. 'A' (REV)7TH-2 - ELEV. 'A' (REV)8TH-1 - ELEV. 'A' (STD)9TH-1 - ELEV. 'A' (REV)10TH-2 - ELEV. 'A' (STD)11UPGRADED END CONDITION

TH-2 - ELEV. 'A' (REV)12

8'-1"

10'-0

"8'-

8"6'-

10"

6'-10

"

6:128:12

6:12

14:12 14:12

6:126:126:12

FINISHED GRADETOP OF WINDOW

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

FINISHED GRADE

TOP OF WINDOW

TOP OF WINDOW

TOP OF SLAB

FG.FG.

FG. 1'6'-

10"

TOP OF TRANSOMTOP OF WINDOW

6'-10

"

TOP OF WINDOW

8'-1"

10'-0

"8'-

8"

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

LEFT SIDE ELEVATION - BLOCK 4UPGRADED END CONDITIONTH-2 - ELEV. 'A' (REV)7

6'-1"

8'-1"

10'-0

"8'-

8"6'-

10"

6'-10

"1'-

0"

6:12

14:12

14:12

SUNKEN FOYERFINISHED GRADE

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

TOP OF SLAB

TOP OF WINDOWTOP OF TRANSOM

FINISHED GRADE

FG. FG.

FG.

1'6'-

10"

TOP OF TRANSOMTOP OF DOOR/WIN

6'-10

"

TOP OF WINDOW

8'-1"

10'-0

"8'-

8"

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

RIGHT SIDE ELEVATION - BLOCK 4UPGRADED END CONDITIONTH-2 - ELEV. 'A' (REV)12

8'-1"

10'-0

"8'-

8"1'-

0"6'-

10"

6'-10

"5'-

5"

6:12

14:12

14:12

TOP OF SLAB

TOP OF PLATE

SECOND FLOOR

GROUND FLOOR

TOP OF WINDOW

TOP OF TRANSOMTOP OF WINDOW

SUNKEN FOYER

FINISHED GRADE

A5scale

project #

project

page

revisions date dwn chk#

client

model

File:

C:\

_RN_

Stan

dard

s\te

mp\

AcPu

blish

_426

4\17

047-

TH-B

LOC

K-HL

.dw

g Pl

otte

d: O

ct 1

8, 2

017

By:p

aula

h

1/8" = 1'-0"

17047

Grand Valley,Town of

Hollenbeck

Cachet EstateHomes Inc.

TH-BLOCK

SIGNATURE:

I, DECLARE THAT I HAVE REVIEWED AND TAKENDESIGN RESPONSIBILITY FOR THE DESIGN WORK ON BEHALFOF RN DESIGN LTD,UNDER DIVISION C,PART-3 SUBSECTION-3.2.4OF THE BUILDING CODE. I AM QUALIFIED AND THE FIRM ISREGISTERED IN THE APPROPRIATE CLASSES / CATEGORIES.

QUALIFIED DESIGNER BCIN:FIRM BCIN:DATE:

PRELIMINARY-NOT

FOR CONSTRUCTION

ISSUED FOR SPA 19-OCT-17 PH MSA1