rms/cops workshop vi 1 october 06, 2015. antitrust admonition ercot strictly prohibits market...

13
RMS/COPS Workshop VI 1 October 06, 2015

Upload: naomi-bryan

Post on 18-Jan-2016

216 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RMS/COPS Workshop VI 1 October 06, 2015. Antitrust Admonition ERCOT strictly prohibits Market Participants and their employees who are participating in

RMS/COPS Workshop VI

1

October 06, 2015

Page 2: RMS/COPS Workshop VI 1 October 06, 2015. Antitrust Admonition ERCOT strictly prohibits Market Participants and their employees who are participating in

Antitrust Admonition ERCOT strictly prohibits Market Participants and their employees who are

participating in ERCOT activities from using their participation in ERCOT activities as a forum for engaging in practices or communications that violate the antitrust laws. The ERCOT Board has approved guidelines for members of ERCOT Committees, Subcommittees and Working Groups to be reviewed and followed by each Market Participant attending ERCOT meetings. If you have not received a copy of these Guidelines, they are available at http://www.ercot.com/about/governance/index.html.

Please remember your ongoing obligation to comply with all applicable laws,

including the antitrust laws.

Disclaimer: All presentations and materials submitted by Market Participants or any

other Entity to ERCOT staff for this meeting are received and posted with the acknowledgement that the information will be considered public in accordance with the ERCOT Websites Content Management Operating Procedure.

2

Page 3: RMS/COPS Workshop VI 1 October 06, 2015. Antitrust Admonition ERCOT strictly prohibits Market Participants and their employees who are participating in

Agenda Introductions Understanding the Background that drove Nodal

Protocol Revision Request 711 (NPRR711):    Market Responses to Questions Identified during

prior Workshops and more recently through comments:

Review and Discuss NPRR 711 Comments filed http://www.ercot.com/mktrules/issues/NPRR711#keyd

ocs

Action Items/Next Steps

3

Page 4: RMS/COPS Workshop VI 1 October 06, 2015. Antitrust Admonition ERCOT strictly prohibits Market Participants and their employees who are participating in

ERCOT Protocols Section 2 Protocol Section 2 Definitions and Acronyms:

Interval Data Recorder (IDR) A metering device that is capable of recording energy in each Settlement

Interval under Section 9, Settlement and Billing, and Section 10, Metering.

Interval Data Recorder (IDR) Meter An IDR where the ESI ID is required to be assigned a BUSIDRRQ Load

Profile Type code and data is submitted in accordance with Section 10.3.3.3, Submission of Settlement Quality Meter Data to ERCOT.

Interval Data Recorder (IDR) Meter Mandatory Installation Requirements The kW (kVA) level at which the installation of an IDR Meter is required

for Settlement purposes as set forth in Section 18.6.1, Interval Data Recorder Meter Mandatory Installation Requirements.

4

Page 5: RMS/COPS Workshop VI 1 October 06, 2015. Antitrust Admonition ERCOT strictly prohibits Market Participants and their employees who are participating in

ERCOT Protocols Section 10

5

Page 6: RMS/COPS Workshop VI 1 October 06, 2015. Antitrust Admonition ERCOT strictly prohibits Market Participants and their employees who are participating in

ERCOT Protocol Section 18 Protocol Sections 18.6

Installation and Use of Interval Data Recorder Meters: 18.6.1 Interval Data Recorder Meter Mandatory Installation

Requirements(1) Interval Data Recorder (IDR) Meters are required and shall be installed and utilized for Settlement of Premises having either:

(a) A peak Demand greater than 700 kW (or 700 kVA in CenterPoint Energy’s service territory); or

(b) Service provided at transmission voltage (above 60 kV).

(2) For the IDR Meter installation process, refer to the Retail Market Guide Section 7.13.2.2, Mandatory Interval Data Recorder Installation Process.

6

Page 7: RMS/COPS Workshop VI 1 October 06, 2015. Antitrust Admonition ERCOT strictly prohibits Market Participants and their employees who are participating in

Retail Market Guide Section 7 Retail Market Guide Section 7.13.2.2

Mandatory Interval Data Recorder Installation Process. Each month following ERCOT’s publishing of the IDR

Requirement Report, the CR has 30 days to verify that each ESI ID meets the requirements of Protocol Section 18.6.1, Interval Data Recorder Meter Mandatory Installation Requirements, and if so, initiate the appropriate request to the TDSP or notify the TDSP of any discrepancies for investigation.

(a) If the IDR Meter installation request meets the Protocol requirements, the CR shall initiate a request to the TDSP for an IDR Meter to be installed using one of the following options:

7

Page 8: RMS/COPS Workshop VI 1 October 06, 2015. Antitrust Admonition ERCOT strictly prohibits Market Participants and their employees who are participating in

Retail Market Guide Section 7 Mandatory Interval Data Recorder Installation

Process (cont.):

(i) Send the appropriate 650_01, Service Order Request, requesting an exchange of the current meter to an IDR Meter installation, also included in the TX SET transaction the CR will provide in the comments/text field the reason for the exchange request (example, ESI ID met mandatory install requirements) along with all CR and Customer contact information in order that the TDSP can appropriately coordinate and schedule the request with the CR and/or Customer.

(ii) Complete Section 9, Appendices, Appendix H2, Interval Data Recorder (IDR) Meter Installation Request Form, and submit it by e-mail to the appropriate TDSP for processing at the TDSP’s e-mail address listed in Table 29, TDSP E-mail Addresses for the IDR Installation Request Form.

8

Page 9: RMS/COPS Workshop VI 1 October 06, 2015. Antitrust Admonition ERCOT strictly prohibits Market Participants and their employees who are participating in

IDR Meter with BUSIDRRQ Load Profile Assigned

9

MDMS Converted

to/or MV90

Systems

MDMS Converted

to/or MV90

Systems

Usage and Billing

System

Usage and Billing

System

IDR or AMSMeter

Meter Data Manager conversion to/or MV90 System

Data Retrieval: AMS Data Collection

or Telephone

Line or

Field Polled at Meter

ERCOT Transaction Management

Systems and NASEB Server

Transaction Management

Systems and NASEB Server

REPS Customers

867_03 Monthly Cycle

and Interval Data

Billing and

Invoicing by REP

15-Minute Interval Data with Reads

used for 867 Monthly

Usage Transaction Processing”

867_03 Monthly Cycle

and Interval Data

Page 10: RMS/COPS Workshop VI 1 October 06, 2015. Antitrust Admonition ERCOT strictly prohibits Market Participants and their employees who are participating in

Interval Data Recorder (IDR) Meter Process TDSPs collect readings and usage from IDR or AMS

Meters through either: Meter Data Management Systems (MDMS) Automated Processes Telephone/Dial-up Communications Meter Crew Polling IDR meter at Premise

Reading and Usage Data processed to create the Monthly 867_03 TX SET transaction Monthly readings along with 15-minute interval data is

processed according to TDSP’s Monthly Cycle Read Schedule

TDSPs will communicate these readings and interval data to ERCOT and REP of Records via the TX SET 867_03 Monthly Usage transaction for ERCOT’s Real Time Market (RTM) Settlements and REPs of Record for their Customer’s Invoice.

10

Page 11: RMS/COPS Workshop VI 1 October 06, 2015. Antitrust Admonition ERCOT strictly prohibits Market Participants and their employees who are participating in

AMS Data Flow Overview

11

Data Collection

Data Collection

Meter Data Management

System(MDMS)

Meter Data Management

System(MDMS)

Customer Information

System (CIS)

Customer Information

System (CIS)

Daily Register Read and Interval Usage Data

REPS

Retailers

“Daily15-Minute Interval DataLSE Files”

COLLECTOR

SMT

ERCOT

Customers

Register Read for 867 Processing

Transaction Management

Systems and NASEB Server

Transaction Management

Systems and NASEB Server

“867 Readings along with

Summarized Usage”

Daily 15-Minute Interval Data

LSE Files

Page 12: RMS/COPS Workshop VI 1 October 06, 2015. Antitrust Admonition ERCOT strictly prohibits Market Participants and their employees who are participating in

AMS LSE Data Process Usage and Register Reads collected from

AMS meters through TDSP’s automated communications process.

Register Reads and Usage are processed in Meter Data Management Systems (MDMS)

LSE Interval Data is produced Daily LSE Files containing 15-minute Interval

Data is sent to both ERCOT for Real Time Settlements (RTM) and Smart Meter Texas (SMT) for Customer’s and REP of Record’s use.

12

Page 13: RMS/COPS Workshop VI 1 October 06, 2015. Antitrust Admonition ERCOT strictly prohibits Market Participants and their employees who are participating in

Questions?

13