rms (room monitoring status)

2
rms (Room monitoring status) System description, September 2009 The use of the rms system in a hotel room enables the monitoring of room status. When a guest opens a room and inserts the card in the card holder, electric circuits are activated and the room status at the reception desk changes. If a chambermaid or a member of the hotel staff enters the room, the status on the reception desk will be displayed as “staff. With the real-time monitoring of rooms, the guests will not have to be unnecessarily inconvenienced, and all services can be performed with increased speed and efficiency. Functionality The system is comprised of the hardware and software parts which form a complete unit for monitoring room status. Card holder (VingCard) Reads data on card type (guest, employee) and transfers the card data to the in-room rms module. The card holder uses the magnetic stripe reader and contactless MIFARE reader technologies. In-room rms module The module collects data on the inserted card, card type (guest, staff), the condition of additional sensors (door and windows contact) and SOS signals. Depending on room status, contact is given to turn the air- conditioning unit on or off. The collected data are sent wirelessly (2.4GHz IEEE802.15.4) to the rms control module. The rms control module It wirelessly collects data from all the in-room rms modules connected to it. The collected data are forwarded via LAN network to the rms program for room status monitoring.

Upload: spica-sustavi-doo

Post on 30-Mar-2016

220 views

Category:

Documents


2 download

DESCRIPTION

The use of the rms system in a hotel room enables the monitoring of room status. When a guest opens a room and inserts the card in the card holder, electric circuits are activated and the room status at the reception desk changes. If a chambermaid or a member of the hotel staff enters the room, the status on the reception desk will be displayed as “staff”. With the real-time monitoring of rooms, the guests will not have to be unnecessarily inconvenienced, and all services can be performed with increased peed and efficiency.

TRANSCRIPT

Page 1: rms (Room monitoring status)

rms (Room monitoring status) System description, September 2009

The use of the rms system in a hotel room enables the monitoring of room status. When a guest opens a room

and inserts the card in the card holder, electric circuits are activated and the room status at the reception desk

changes. If a chambermaid or a member of the hotel staff enters the room, the status on the reception desk will

be displayed as “staff”. With the real-time monitoring of rooms, the guests will not have to be unnecessarily

inconvenienced, and all services can be performed with increased speed and efficiency.

Functionality

The system is comprised of the hardware and software parts which form a complete unit for monitoring

room status.

Card holder (VingCard)

Reads data on card type (guest, employee) and transfers the card data to the in-room rms module.

The card holder uses the magnetic stripe reader and contactless MIFARE reader technologies.

In-room rms module

The module collects data on the inserted card, card type (guest, staff), the condition of additional sensors

(door and windows contact) and SOS signals. Depending on room status, contact is given to turn the air-

conditioning unit on or off. The collected data are sent wirelessly (2.4GHz IEEE802.15.4) to the rms control

module.

The rms control module

It wirelessly collects data from all the in-room rms modules connected to it. The collected data are forwarded

via LAN network to the rms program for room status monitoring.

Page 2: rms (Room monitoring status)

rms program

After the VingCard lock is opened, the room is entered and the card is inserted in the card holder, the rms

controller wirelessly forwards the data to the central rms module (the number and layout of the devices is

determined depending on the size of the hotel and the possibility of wireless corridor coverage) which then

forwards the data through the LAN network to the reception desk software.

The VingCard intelligent controller distinguishes the guest card from the employee card and on that basis

displays the room status on the reception software with the accompanying reports.

The room status enables reports for hotel staff (a report on guest presence in the room, open windows, etc. is

available at all times).

When the card is inserted, besides the forwarding of data, the welcome light and the air-conditioning are

activated. The data visible on the reception desk enable the forced activation or deactivation of the air-

conditioning unit.

rms basic

VingCard card holder with the integrated in-room rms module

rms control module

rms basic program

Functions: displaying presence in the room (guest or staff)

rms advanced

VingCard card holder

Advanced rms in-room module

rms control module

rms advanced program

Functions: displaying presence in the room (guest or staff), displaying open or closed doors and

windows in the room, SOS signal, activation of the air-conditioning unit

System types

Špica Sustavi d.o.o I R. Cimermana 64, 10000 Zagreb, Croatia I T: + 385 (0)1 6593 730 I