RMS alarm under IHA decontamination. 2012. 9. 25. Korea Hydro & Nuclear Power. Shin-Kori Nuclear Power Plant. INTRODUCTION. During the Operation, Occurring the Radiation Particle. Appropriate Protection. Dose reduction. Protection from Internal Exposure. As Low As Resonably Achievable. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: RMS alarm under IHA decontamination

RMS alarm under IHA decontamination

RMS alarm under IHA decontamination

2012. 9. 25

Shin-Kori Nuclear Power Plant

Korea Hydro & Nuclear Power

Page 2: RMS alarm under IHA decontamination

INTRODUCTIONINTRODUCTION

During the Operation, Occurring the RadiationParticle

Appropriate Protection

Dose reduction

Protection from Internal Exposure

As Low As Resonably Achievable

Page 3: RMS alarm under IHA decontamination

Title : IHA Cleaning operation

Period : 2012. 1. 26 ~ 2012. 1. 28

Purpose : Removal of the foreign substance attached to IHA

Operation personnel : 12person

INTRODUCTIONINTRODUCTION

Page 4: RMS alarm under IHA decontamination

WORK PLACEWORK PLACE

refueling pool arearefueling pool area

S/G cavity BS/G cavity B

S/G cavity AS/G cavity A

UCSA & upper Air Plenum AreaUCSA & upper Air Plenum Area

P/HP/H

E/HE/H

IHA storage AreaIHA storage Area

Page 5: RMS alarm under IHA decontamination

Dry Ice Cleaning TheoryDry Ice Cleaning Theory

Page 6: RMS alarm under IHA decontamination

1. Sublimate Material

2. Carbon Dioxide Created by Compressing and Cooling

3. Liquefied At a Low Temperature

4. Sublimation as to supply heat to the surround and foreign objects fall as expended

Dry Ice FeaturesDry Ice Features

Page 7: RMS alarm under IHA decontamination

Work ProcedureWork Procedure

1. Spray DryIce on the IHA

2. The operator wears a mask

3. Work environment Spatial Dose = 5μSv/hr, No airborne particle

4. Work with the Radiation Safety Manager

Page 8: RMS alarm under IHA decontamination

Attached Boric acid Attached Boric acid

Page 9: RMS alarm under IHA decontamination

Cleaning of Boric acidCleaning of Boric acid

Page 10: RMS alarm under IHA decontamination

LCSA CleaningLCSA Cleaning

Cleaning internal IHACleaning internal IHA

Page 11: RMS alarm under IHA decontamination

Radiation Monitor AlarmRadiation Monitor Alarm

During the Dryice spray, Alarm occurs in the Radiation Monitoring System(RMS)

The alarm Caused by Radioactive particle

Workers complete the decontamination, and leave the workplace

Airsampling is Performed, Checking Exposure

Radioactive Particles blow into the air with the dryice

Page 12: RMS alarm under IHA decontamination

RMS Alert / HighRMS Alert / High

Page 13: RMS alarm under IHA decontamination

RMS Line DrawingRMS Line Drawing

Page 14: RMS alarm under IHA decontamination

PrecautionPrecaution

Page 15: RMS alarm under IHA decontamination

PrecautionPrecaution

1. Tent is installed in the workspace

2. Workers are wearing a mask

3. Discharged to the outside from inside the tent through the air ventillation

4. More Clothes on the outside, In order to prevent additional contamination

Page 16: RMS alarm under IHA decontamination

ResultsResults

1. Workers are not internal Exposure

2. Total External Dose = 0.9man-mSv(total : 10person) This Dose is due to the spatial dose

3. IHA thoroughly cleaned

4. Radiation Monitoring System was normal operation

Page 17: RMS alarm under IHA decontamination

Comparison on decontamination Comparison on decontamination Before work / After workBefore work / After work

Page 18: RMS alarm under IHA decontamination

ConclusionConclusion

1. Radioactive Particle Floats in the Air. It causes Internal exposure.

2. Maybe necessary Paricles occuring in the workplace should not be entered into the human body

3. IMA cleaning need something like the size of the tent because of the size and installed to perform the operation.