rj series hll configuration technical...
TRANSCRIPT
"RJ" Series "HLL" Configuration Technical Drawings
/^<sr
t_
\^\
HOLE DIA.4 PLC'S.
_i
^==~^
3J
Back Panel Available(see page 246)
i»
SECTION A-A
FRONT VIEWWITHOUT COVER
"RJ" Series Enclosures - "HLL " Configuration Dimensions •̂ ^ •̂̂ ^^ •̂̂ •̂̂ ^ •̂•̂ ^ •̂1SIZE ID
NUMBERRJ 604HLL
RJ 606HLL
RJ 806HLL
RJ1008HLL
RJ1210HLL
RJ 1412HLL
RJ1614HLL
RJ1816HLL
RJ 2016HLL
OVERALLH X W X D
7.50 x 5.47 x 6.22( 1 9 1 x 1 3 9 x 1 5 8 )7.50 x 7.52 x 6.22(191 x 1 9 1 x 1 5 8 )9.62 x 7.46 x 6.22( 2 4 4 x 1 9 0 x 1 5 8 )
1 1 . 6 2 x 9 . 3 7 x 6 . 6 1( 2 9 5 x 2 3 8 x 1 6 8 )
1 3 . 5 6 x 1 1 . 4 3 x 6 . 6 1( 3 4 4 x 2 9 1 x 1 6 8 )
1 5 . 5 0 x 1 3 . 3 8 x 7 . 6 9( 3 9 4 x 3 4 0 x 1 9 5 )
17.53x15.43x7.71( 4 4 5 x 3 9 2 x 1 9 6 )
1 9 . 6 2 x 1 7 . 4 8 x 1 0 . 6 2(498 x 444 x 270)
22 .00x17 .56x10 .64(559 x 446 x 270)
INSIDEA X B X C
5.84 x 3.85 x 5.95( 1 4 8 x 9 8 x 1 5 1 )
5 .72x5 .72x5 .95( 1 4 5 x 1 4 5 x 1 5 1 )7.73 x 5.74 x 5.95( 1 9 6 x 1 4 6 x 1 5 1 )9.73 x 7.73 x 6.36( 2 4 7 x 1 9 6 x 1 6 2 )
1 1 . 7 9 x 9 . 8 0 x 6 . 3 2( 2 9 9 x 2 4 9 x 1 6 1 )
1 3 . 5 3 x 1 1 . 5 5 x 7 . 4 5( 3 4 4 x 2 9 3 x 1 8 9 )
15.63x13.60x7.45( 3 9 7 x 3 4 5 x 1 8 9 )
1 7 . 6 9 x 1 5 . 6 9 x 1 0 . 3 1(449 x 399 x 262)
1 9 . 7 2 x 1 5 . 7 2 x 1 0 . 3 3(501 x 399 x 262)
MOUNTINGE X F
6.75 x 2( 1 7 1 x 5 1 )6.75 x 4
(171 x 1 0 1 )8.88 x 4
( 2 2 5 x 1 0 1 )1 0 . 7 5 x 6
(273x152 )1 2 . 7 5 x 8
(324 x 203)1 4 . 6 2 x 1 0
(371 x 254)16 .75x12(425 x 305)1 8 . 8 8 x 1 2(479 x 305)
?1 . 2 5 x 1 0 . 0 0(540 x 254)
J5.49(140)5.49(140)5.49(140)5.91(150)5.87(149)6.87(174)6.87(174)9.86(250)9.87(251)
K4.25(108)4.25(108)6.25(159)8.25(209)10.25(260)12.25( 3 1 1 )14.25(362)16.25(413)18.25(464)
L2.25(57)4.25(108)4.25(108)6.25(159)8.25(209)10.25(260)12.25( 3 1 1 )14.25(362)14.25(362)
M0.25(6)
0.25(6)
0.25(6)
0.25(6)
0.25(6)
0.25(6)
0.25(6)
0.25(6)
0.25(6)
N7.45(189)7.52
(191)9.36(238)1 1 . 3 8(289)13.41(341)15.42(392)17.43(443)19.49(495)21.56(548)
05.31(135)5.34(136)7.25(185)9.3
(236)1 1 . 2(284)13.2(335)15.2(386)17.25(438)0.31(8)
P3.34(85)5.31(135)5.28(134)7.38
(188)9.23(234)1 1 . 1 6(284)13.24(336)15.25(387)19.31(490)
HOLEDIA.0.31(8)
0.31(8)
0.31(8)
0.31(8)
0.31(8)
0.31(8)
0.31(8)
0.31(8)
15.39(391)
ENCLOSUREWEIGHT2,5 Ibs.
2.75 Ibs.
3.5 Ibs.
5 Ibs.
6.5 Ibs.
8.5 Ibs.
11. 5 Ibs.
19.25 Ibs.
20.25 Ibs.
PANELNUMBER
BP-64
BP-66
BP-86
BP-108
BP-1210
BP-1412
BP-1614
BP-1816
BPJ2016
•J
All measures are in inches, items in parentheses are in millimeters.
Stahlin Enclosures • 500 Maple Street, Belding, Ml 48809 • Phone: 616-794-0700 • Fax: 616-794-3378 • www.stahlin.com
108
General Information continued on following pages
NEMA 12 'ndoor use to provide a degree of protection~~ against falling dirt; circulating dust, lint, fibers and
flyings; and dripping and light splashing of liquids.
NEMA 13 lndoor use to Provide a degree of protectionagainst falling dirt; circulating dust, lint, fibers andflyings; and spraying, splashing and seepage ofwater, oil and non-corrosive coolants.
Reference Documents and SourcesNEMA Standards Publication 250, Enclosures for Electrical Equipment (1000 VoltsMaximum) and NEMA Standards Publication ICS6, Enclosures for IndustrialControls and Systems.National Electrical Manufacturers Association1300 North 17th ST, Suite 1847Rosslyn, VA 22209 '
CSA Standard C22.2 No. 14 Industrial Control Equipment for Use in Ordinary(Non-Hazardous) Locations; CSA Standard C22.2 No. 40 Cut-Out, Junction andPull Boxes; and CSA Standard 22.2 No. 94 Special Purpose EnclosuresCanadian Standards Association178RexdaleBlvd.Etobicoke, Ontario, Canada M9W 1R3
UL 50 Enclosures for Electrical Equipment; UL 94 Tests for Flammability ofPlastic Materials for Parts in Devices and Appliances; UL 508 Industrial ControlEquipment; UL 870 Wireways, Auxiliary Gutters and Associated Fittings; andUL 746C Polymeric Materials - Use in Electrical Equipment EvaluationsUnderwriters Laboratories333 Pfingsten RoadNorthbrook, IL 60062-2096Underwriters Laboratories of Canada7 Grouse RoadScarborough, Ontario, Canada M1R 3A9
IEC 529 Classification of Degrees of Protection Provided by EnclosuresIEC 204 Electrical Equipment of Industrial MachinesInternational Electrotechnical Commission1 Rue de VarembeiCH-1211Geneva 20, Switzerland
ANSI Z55.1 Gray Finishes for Industrial Apparatus and EquipmentAmerican National Standards Institute1430 BroadwayNew York, NY 10018
Comparison of Enclosure Types for Non-hazardous LocationsProvides a Degree of Protection Against the Type of EnclosureFollowing Environmental Conditions
1 3 3R 4 4X 6 6P 12 13Incidental Contact with Enclosed Equipment •Indoor •OutdoorFalling Dirt •Dripping and LigMjSpJashing LiquidsRain, Sleet*, SnowCirculating Dust, Lint, Fibers and FlyingsSettling Dust, Lint, Fibers and FlyingsExternal Ice* •Hosedown and Splashing Water
• •• •
• •• •
• •• •
Oil and Coolant Seepage • •Oil and Coolant Spraying and Splashing •Corrosive Agents • •Occasional Temporary Submersion • •Occasional Prolonged Submersion •
'External operating mechanisms are not required to be operable when the enclosure is ice covered
Stahlin Enclosures • 500 Maple Street, Belding, Ml 48809 • Phone: 616-794-0700 « Fax: 616-794-3378 • www.stahlin.com I
The "RJ" Series
•jtfiZjfrMfWl niijiiliijhto
The "RJ" SeriesThe "RJ" Series enclosures also follow the original design of fiberglass enclosure products featuring an overhang cover on a
flange mounted base. The variation refers to a "raised" or "deeper" cover that does not affect the height of the base. Productsthat are engineered into a "J" series footprint but which require an additional inch and a half depth to accommodate tall orelongated components will find that this enclosure fully meets their requirements. Unobstructed side-walls, built in mountingcapabilities and depth of cover offer a full range of possibilities when working with this enclosure.
"RJ" series enclosures are designed for general electrical and electronicapplications and any application that has associated environmental ________________concerns. Simple in its design, the enclosure can be configuredwith cutouts, windows and modifications that make your finishedproduct truly unique.
"RJ" series products accommodate standard backpanel mounting but offer a range of panels, including anelevated dead front panel that is highly visible through acover mounted window. This feature can beparticularly effective with cover mounted components.
"RJ" Series Attributes• Overhang cover on smooth sided base• Extra depth in cover for cover mounted
components• All stainless hardware latches and screws• Full length stainless steel hinge• Chemically resistant fiberglass reinforced
polyester• Submersible, non corrosive, environmental designs• Exclusive stainless steel retention chain on
screw covers
"RJ" Series Specifications• Watertight
• Submersible
• Corrosion resistant
• Fire resistant
• Light weight
• RatedNEMA1,3,4X,6P, 12
• UL/cUL approved
• CSA Approved
The "RJ" Series is Applicable for Many Industries including:OEMS
Instrumentation Designs Pump Control SystemsWaters
Wastewater ProcessingAutomatic
Oiling Systems
&STAHLIN The "RJ" Series RJ
I""
The "RJ" Series Family consists of fourbasic concepts: screw downcover, hinged cover with screwdown, a twist lock latch and apadlock latch. There are ninebasic sizes in the range.
Simple screw down coverstyle enclosures employ anindustry exclusive stainless
steel retention chain. Eachof these configurations isequally at home inaggressive environmentsor cosmetically challenged
installations.
"RJ" Series Ordering InformationUse the information below to derive specific catalog numbers. Stahlincatalog numbers first begin with Family ID, then size ID and configu-ration ID as a suffix. See the example below.
Ordering Information - Deriving Catalog NumbersFamily ID \ Size ID
RJ XXXX
Configuration ID
Conf. ID =
EXAMPLE
"RJ604W"
"RJ" SeriesSize IDRJ604RJ606RJ806RJ1008RJ1210RJ1412RJ1614RJ1816RJ2016
- Inside DimensionsH xW xD
5.84 x 3.85 x 5.955.72 x 5.72 x 5.957.73 x 5.74 x 5.959.73 x 7.73 x 6.361 1 .79 x 9.80 x 6.3213 .53x11 .55x7 .4515.63x13.60x7.4517.69x15.69x10.3119 .72x15 .72x10 .33
Optional Panel #BP64BP66BP86BP108BP1210BP1412BP1614BP1816BPJ2016
Optional back panels available in various materials. See page 246
"RJ" Series - ConfigurationsConfigurationID DESCRIPTIONWHWHLLHPLFHW
4 cover screws, lift off cover configurationHinged, 2 cover screws configuration
JHingedJink lock latch configuration____Hinged, padlock latch configurationFiberglass hinged, 4 cover screws configuration
FHLLFHPL
Fiberglass hinged, link lock latch configurationFiberglass hinged, padlock latch configuration
"RJ" Series Shared CharacteristicsConstructionMaterial Hot compression molded fiberglass
reinforced polyester_______Gasket Poured polyurethane seamless
gasket provides watertight, dust-tightenvironmental seal
Recessed ScrewsStainless Steel Hardware
No protruding surfaces300 Series stainless used on allexternal hardware
Cover depth ______Molded in Mounting Flange
Extra depth molded into coverIntegral flange molded in place forease of mounting________
Mounting Bosses Panel mounting capability for fixedrear panel
Metal inserts
Soft Edge Design
All bosses utilize threaded brass insertsaccepting 10-32 screws _ ___ _Rounded edges, minimal protrusions orexposed pocket areas for assembly ofdust and debris
Physical CharacteristicsNon corrosive
Water-tight
Dust-tight
Impact resistant
Non Conductive
Light weight
UV resistantWorkable material
Easy maintenance
Pleasing aesthetics
Color/Finish
Stands up to an exceptionally broadrange of chemical exposuresRated watertight and submersible for aprolonged periodResults in an environmentally sealed,environmentally sound spaceResilient material with high impactresistanceDouble insulated material. No incidentalelectrical contactSolid construction in a lightweightdesignMinimizes the affects of sunlightCuts, drills, punches, and saws withease and accuracyScratches and gouges can be restoredwith a petroleum jelly productSmooth lines, soft colors easily blendinto customer's design conceptsSmooth surface, no color variations,swirls, or color pockets, no voids.Color described as Glacier Gray
Industry StandardsUL/cUL 50 File E64358
Type 1 , 3 , 4X, 6P, 12NEMA 250CSA Std C22.2
JypeJ.a.^.jiFvlJLFile LR069014Type 1 , 3 , 4X, 6P, 12
Temperature Range_____(-40"F to •Fjanimability Rating_____UL94-5VWindow Tlammability____UL94V-0
(-40°F to +250°F) (-40°C to +120°C)
Self extinguishing Non-flame propagatingChemical Resistance Full chemical resistance charts listed in
appendix
Stahlin Enclosures • 500 Maple Street, Belding, Ml 48809 • Phone: 616-794-0700 • Fax: 616-794-3378 • www.stahlin.com
99
Technical Specifications - "RJ" Series
yRJ
"HLL" configuration - Hinged, link lock latch
HLL ConstructionMaterial^Gasket
JHot_compression molded fiberglass reinforced polyesterPoured polyurethane seamless gasket provides watertight,dust-tight environmental seal ___ ______
Stainless Steel Hardware 300 Series stainless used on all external hardwareMolded in Mounting Flange Integral flange molded in place for ease of mountingMounting Bosses___Metal inserts
Panel mounting capability for fixed rear panel __All bosses utilize threaded brass inserts accepting 10-32 screws
Soft Edge Design Rounded edges, minimal protrusions or exposed pocket areas forassembly of dust and debris_________________
Raised cover Extended depth in cover
HLL Industry StandardsUL/cULJjn^NEMA250
Jile E64358 Type 1, 3, 4X, 6P, 12Typei,3,4X76FVI2r_____
CSA Std C22.2FU1008HLL Temperature Range
Flammability Rating
FileLR069014 Type 1.3.4X. 6P, 12
Window FlammabilitySelf Extinguishing _Chemical Resistance
(-40°F to +250°F) (-40"C to +12Q°C)JJL94-5V__UL94V-0__
Non-flame propagatingFull chemical resistance charts listed in appendix
HLL Accessories
Back PanelsAluminumFiberglass
ORDERING INFOBP ALBP_FG
pg. 246pg. 246
—— <Stainless Steel BP_SSPainted Carbon Steel
Special AccessoriesSurface mount windowsTerminaTKit
BP CS_PfiJ4<L
pg. 246
pg. 237TK_ pg. 253
Encapsulated cover screwsVentLouver________Carrying Handle_____
__WP4P_KENCAP__JVK3KIT 'J.PK3KIT _____
RMEMK109506
pg. 241pg. 241pg. 241pg. 241
Fiberglass pedestals JP3336 pg. 243Assorted hubs and cord grips five assorted ranges_ pg. 242, 243, 244Vapor capsule
HLL Modifications
VC2-1 pg. 241
See Special ModRight™ Modification pg 235, 236
ORDERING INFORemovable dead front panelsGrounding stud_______Custom painting_________Silk screening_______
pg. 249pg. 236pg. 235pg. 235
DecalsEMI/RFI shielding
_Pfl._235__P9^235_
Custom windowCustom cutouts
pg. 235pg. 235
Custom hole drilling pg. 235Custom blending pg. 235
Stahlin Enclosures • 500 Maple Street, Belding, Ml 48809 • Phone: 616-794-0700 • Fax: 616-794-3378 • www.stahlin.com107