riser diagram - sdc security · model : e5rm s/n : 12345678. k3 alarm strike door sensor exit...
TRANSCRIPT
PROJECT NAME: DISTRIBUTOR:
DWG. NO.: 0033
DWN BY: MLDATE: 08-2007
SECURITY DOOR CONTROLS3580 Willow Lane
Westlake Village CA 91361-4921Tel. 805-494-0622 FAX: 805-494-8861
LOCATION:
CONTACT:
SO. NO.:
© 2009 Security Door Controls Printed in U.S.A
EMLock® EntryCheck™ExitCheck® Selectric® Spacesaver® HiTower® SureExit®
PAGE 1 OF 2
RISER DIAGRAM
NOTES: (1) ALL LOW VOLTAGE SIGNAL WIRING SHALL BE 20-GAUGE MINIMUM. THE MINIMUM INDUCTIVE LOAD (LOCK) POWER WIRE GAUGE SHALL BE DETERMINED PER THE SDC WIRE GAUGE CHART. ALL WIRING (SINGLE OR MULTI-CONDUCTOR) SHALL BE COLOR CODED WITHOUT SPLICES. A MINIMUM OF TWO SPARE CONDUCTORS IS RECOMMENDED. (2) SPECIFY VOLTAGE WHEN ORDERING PRODUCTS. VOLTAGE IS NOT SPECIFIED ON THIS WIRE DIAGRAM, BE SURE ALL PRODUCTS ARE VOLTAGE COMPATIBLE. (3) ALL WIRING MUST CONFORM TO NATIONAL, STATE AND LOCAL CODES. (4) ALWAYS CONSULT WITH THE AUTHORITY HAVING JURISDICTION (AHJ) BEFORE INSTALLATION. (5) WHERE REQUIRED BY CODE, CONNECT FAILSAFE SYSTEMS TO THE LOCAL FIRE LIFE SAFETY SYSTEM FOR EMERGENCY RELEASE.
602RF POWER SUPPLY TO 120VAC POWER SOURCE
TO FIRE ALARM – CLOSED CONTACT CONNECTION
2 COND
4 COND
PUSHTO
EXIT
422 EXIT
BUTTON(INSIDE)
Components
Qty Description Part Number Manufacturer 1 Magnetic Lock 1511 1571 1581 SDC 1 1 Amp Power Supply 602RF SDC 1 Exit Push Button 422U 412NU SDC 1 Proximity/PIN Card Reader E4KP SDC
HID ProxCard II HID-1326 HID
Method of Operation
Access/Egress: Presenting an authorized card to the reader releases the locking device momentarily for access. Pressing the exit switch button releases the locking device momentarily for egress. Entry and exit momentary unlock time is determined by the card reader programming. Emergency Release: All locks will release automatically (see note 5) upon activation of the fire life safety system.
E4KPPROX CARD
READER(OUTSIDE)
4 COND
EMLOCK®
1511, 1571 or 1581AS SPECIFIED BELOW
PROJECT NAME:
DIST.: DWG. NO.:DRAWN BY: DATE:
SECURITY DOOR CONTROLS3580 Willow LaneWestlake Village CA 91361-4921Tel. 805-494-0622 FAX: 805-494-8861
LOCATION.: CONTACT:
SO NO.:
PAGE 2 OF 2
© 2009 Security Door Controls Printed in U.S.A
REV--
DWG0033
TITLE:
- -- -- 08-2007 ML
--NOTE: ALL WIRING MUST BE REVIEWED AND APPROVED BY THE PROJECT ENGINEER ASSIGNED TO THE LOCATION FOR IT’S CORRECTNESS AND SUITABILITY FOR THE APPLICATION IN THE WHICH THE EQUIPMENT INSTALLED AND OPERATED. ALL WIRING MUST CONFORM TO NATIONAL, STATE, AND LOCAL CODES FOR CLASS 2 FIRE PROTECTION AND CONTROL DEVICES.
--
HiTower®Spacesaver®Exit Check® EMLock® Sure Exit® EntryCheck™SELECTRIC®
POINT TO POINT WIRING DIAGRAM
PUSHTO
EXIT
1511, 1571 OR 1581 SERIES MAGNETIC LOCKS422U OR 422NU
MOMENTARY - SPDT
C
NC
NO
YEL
ORG
WHT
+ - C+ -
G
W
B
CLOSED FIRE ALARMCONTACT
+
-
STANDBYBATTERY
CONNECTION
12VDC OUTPUT
(REMOVE FACTORY JUMPER ONLY IF FIRE ALARM IS USED)
REFER TO POWER SUPPLY INSTRUCTIONS FOR 12VDC
VOLTAGE SELECTION PROCEDURE
TO 120VAC PRIMARY VOLTAGE CONNECTION
602 SERIES POWER SUPPLY
24V 12V
NO
NC
COM
NO
NC
COM
POWER
{DPS
BAS
BAS PLUG IN
15111571
1581
NO
NC
COM
NOT USED
POWER
{DPS
34
56
78
34
56{
REDBLKBRNORG
REDBLKBRNORG
J3REDBLKBRNORGYEL
E5RM CONTROLLER RELAY MODULE
NOT USED
REDBLKBRNORGYELGRNBLU
YELGRNBLUYELGRNBLU
J2
J1
REDBLKBRNORGYELGRNBLU
YELGRNBLUYELGRNBLU
300 ft MAX
+12VGND
CLOCKDATA
+-ACCESSCONTROLLER
K3 FUNCTION SETTINGFUNCTION
DURESS/SHUNTGUARDPATROL
1 2 3ON OFF OFF
ONON
OFFOFFOFF OFF
MODEL : E5RMS/N : 12345678
K3
ALARM
STRIKE
DOOR SENSOREXIT BUTTON
INPUT DC12V
ON
1 2 3
CARD READER
E4KP – CARD READER W/ CONTROLLER RELAY MODULE
RED
RED
LAMP