rgsr ser˜es - entes.com.tr · sens˜t˜ve mode opt˜ons • prec˜se measurement up to 3ma w˜th...

2
RGSR Series Power Factor Controller The next generation ENTES RGSR Series power factor controllers with smart SVC function are user-friendly with their plug & play and ease-of-use features. The RGSR series that can perform precise measuring even in quite low currents (3mA) has two steps options 12+SVC and 16+SVC. Basic Features RGSR can control capacitors and reactors instantly thanks to RGSR's SVC support Opportunity to configure the power factor correction activity with eco, standard and sensitive mode options Precise measurement up to 3mA with high precision class Automatic easy setup Triggering the capacitors and the shunt reactor simultaneously By the second current transformer, blowing of step fuse, contactor sticking alarm can be detected and instant capacitor values, contactor life time can be measured. Tracking step value, step setup date and contactor life Daily, weekly, monthly, 3 monthly compensation ratio chart Displaying each phase with Phasor diagram Instant measuring of Capacitor and Reactor values Automatic step recognition and faulty connection correction Displaying the number of step switching Parameters Measured: I,V,W,VAr,VA, kWh,kVARh,kVAH,Cosφ,THDI,THDV

Upload: vanthuy

Post on 26-Jan-2019

212 views

Category:

Documents


0 download

TRANSCRIPT

RGSR SeriesPower Factor ControllerThe next generation ENTES RGSR Series power factor controllers with smart SVC function are user-friendly with their plug & play and ease-of-use features. The RGSR series that can perform precise measuring even in quite low currents (3mA) has two steps options 12+SVC and 16+SVC.

Basic Features• RGSR can control capacitors and reactors instantly thanks to RGSR's SVC support• Opportunity to configure the power factor correction activity with eco, standard and sensitive mode options• Precise measurement up to 3mA with high precision class• Automatic easy setup • Triggering the capacitors and the shunt reactor simultaneously• By the second current transformer, blowing of step fuse, contactor sticking alarm can be detected and instant capacitor values, contactor life time can be measured.• Tracking step value, step setup date and contactor life• Daily, weekly, monthly, 3 monthly compensation ratio chart• Displaying each phase with Phasor diagram• Instant measuring of Capacitor and Reactor values• Automatic step recognition and faulty connection correction• Displaying the number of step switchingParameters Measured: I,V,W,VAr,VA, kWh,kVARh,kVAH,Cosφ,THDI,THDV

Other facilities in the area(Voltage Harmonics -THDV)

Transformer 400V

Power Factor ControllerRGSR

Inductive Reactor Driver

UPS, rectifier, motor drivers etc.

Capacitive Loads(Electronic Ballasted

Luminaire, etc.)

Inductive Loads

ShuntReactors

(Monophase)

Capacitors

HarmonicFilters

SPECIFICATIONSRGSR-15S RGSR-20S

STEP

SUPPLYOperating Voltage (Un)Operating FrequencyMEASUREMENTS FUNCTIONSMeasurement ClassStep Engaging and Releasing, and Discharge DurationTHDV Setting LimitDISPLAYActive AreaColourResolutionOPERATING ENVIRONMENTOperating Environment TemperatureMaximum Relative HumidityCONNECTIONSInstallationPanel Segment SizeMaximum Depth (In-Panel)COMMUNICATION

BOXDimensionsProtection Class

100-270(-15%+10%)VAC/VDC45~60 Hz

%0.5(V,I,W,VAr,VA),%0.02(Hz,Cosθ)1-1800 seconds

%0 – 100

Monochrome graphWhite/Grey Positive

240 x 160 pixels

-20 +70°C95%

Vertical Panel Installation138x138mm

60mm

Modbus RTU

144 x 144 mmIP 51 (Front Panel), IP 20 (From the Back)

12 + SVC 16 + SVC

ShuntReactors

ENTES Elektronik Cihazlar İmalat ve Ticaret A.Ş.

HEADQUARTERSAddress: Dudullu OSB; 1. Cadde; No: 23 34776 Umraniye - ISTANBUL / TURKEY Tel: +90 216 313 01 10 Fax: +90 216 314 16 15 Sales Fax: +90 216 365 71 71E-mail: [email protected] Web: www.entes.com.tr E-bulletin membership: [email protected] Coordinates: 40,995852 N, 29,178398 E

INTERNATIONAL BRANCH OFFICESİSTANBUL : [email protected] Tel: +90 216 313 01 10 Fax: +90 216 314 16 15NETHERLANDS : [email protected] Tel: +31 412 - 644319GREECE : [email protected] Tel: +30 2310 706999 +30 2310 707296GERMANY : [email protected] Tel: +49(0) 7022-931992-0