rgb rigid bar led light strip mri compatible · the led strip. 7) ensure the led strip is securely...

13
DC RGB LED Strip ( Part No. 560-112 ) PDC FACILITIES, INC 700 Walnut Ridge Drive Hartland, WI 53029 262-367-7700 800-545-5998 Fax 262-367-7744 www.pdcbiz.com Page 1 of 3 SPC-560-112 Rev E RGB Rigid Bar LED Light Strip MRI Compatible Product Description A non-ferrous, LED light strip for use within a fixture or under cabinet mounting as an interior architectural design lighting package. PDC LED Light Strips can be used anywhere within a Health Care Facility including MRI Scan Rooms. Specifications Material Housing: Aluminum LEDs Lumens: 344.11 Efficacy: 29.17 Color Rendering Index: 17.2 Color Related Temperature: 52600 60 LED’s / 1m (3.28’) Red/Green/Blue Electrical Input 12 VDC, 11.6 Watts, 0.97Amps Low Voltage 4 Pin Connector Dimensions 15mm x 7.5mm x 1m 0.59” x 0.3” x 36.28” Three Year Limited Warranty Complete Component Approval Listings ETL / UL / CSA / CE Note: The photo is for reference only and may or may not reflect the actual product.

Upload: others

Post on 24-Mar-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RGB Rigid Bar LED Light Strip MRI Compatible · the LED strip. 7) Ensure the LED strip is securely seated and raised from the surface. Wiring Diagram PDC LED Light Strips and fixtures

DC RGB LED Strip ( Part No. 560-112 )

PDC FACILITIES, INC 700 Walnut Ridge Drive Hartland, WI 53029

262-367-7700 800-545-5998 Fax 262-367-7744 www.pdcbiz.com Page 1 of 3 SPC-560-112 Rev E 

RGB Rigid Bar LED Light Strip MRI Compatible

Product Description A non-ferrous, LED light strip for use within a fixture or under cabinet mounting as an interior architectural design lighting package. PDC LED Light Strips can be used anywhere within a Health Care Facility including MRI Scan Rooms.

Specifications

Material Housing: Aluminum LEDs Lumens: 344.11 Efficacy: 29.17 Color Rendering Index: 17.2 Color Related Temperature: 52600 60 LED’s / 1m (3.28’) Red/Green/Blue

Electrical Input 12 VDC, 11.6 Watts, 0.97Amps Low Voltage 4 Pin Connector Dimensions 15mm x 7.5mm x 1m 0.59” x 0.3” x 36.28” Three Year Limited Warranty Complete Component Approval Listings ETL / UL / CSA / CE

Note: The photo is for reference only and may or may not reflect the

actual product.

Page 2: RGB Rigid Bar LED Light Strip MRI Compatible · the LED strip. 7) Ensure the LED strip is securely seated and raised from the surface. Wiring Diagram PDC LED Light Strips and fixtures

DC RGB LED Strip ( Part No. 560-112 )

PDC FACILITIES, INC 700 Walnut Ridge Drive Hartland, WI 53029

262-367-7700 800-545-5998 Fax 262-367-7744 www.pdcbiz.com Page 2 of 3 SPC-560-112 Rev E 

LED Strip Installation Note:  Each LED strips should be wired in parallel not in series.   

Note:  Use only Non‐Ferrous mounting clips and hardware within the MRI environment.   

 

1) Use  the  included  clips  to  support  the  LED  strips  from  the 

surface. 

2) Use three (3) clips per full length strip (1 meter).   

3) Attach the clips to surface using the supplied hardware.   

4) Ensure the clip is firmly secured to the surface. 

 

5) Press the LED strip into the clip without distorting the clip.   

6) The “ridge” within the clip should seat  into the channel along 

the LED strip.   

7) Ensure  the  LED  strip  is  securely  seated  and  raised  from  the 

surface.   

 

Wiring Diagram PDC LED Light Strips and fixtures containing PDC LED Light Strips require a junction box every 7’ (2m) with a maximum of 4 LED Strips connected to each junction box. Each junction box should be supplied by a 16ga WIP. PDC LED Light Strips are to be wired in parallel as depicted below:

Page 3: RGB Rigid Bar LED Light Strip MRI Compatible · the LED strip. 7) Ensure the LED strip is securely seated and raised from the surface. Wiring Diagram PDC LED Light Strips and fixtures

DC RGB LED Strip ( Part No. 560-112 )

PDC FACILITIES, INC 700 Walnut Ridge Drive Hartland, WI 53029

262-367-7700 800-545-5998 Fax 262-367-7744 www.pdcbiz.com Page 3 of 3 SPC-560-112 Rev E 

LED Strip Custom Lengths Note:  PDC will cut to custom lengths for the customer.  However, if the LED Strips require further modification at the customer site, this procedure must be followed.   

Warning:  Observe manufacturer’s recommend safety protocol when working with any type of tool.   

 1) LED Strips are provided in a uniform length of 1m/36.28” each.   

2) Determine the finished length of the LED Strip to be modified.   

3) Transpose the determined length onto the LED Strip measuring from the end with the electrical connector to the closest LED Cut Line.   

4) Measure to the closest LED Cut Line.  If the LED Cut Line is not the exact required length, use the closest LED Cut Line for the intended application (shorter or longer).   

 

5) The LED Cut Line is located between the silver pads denoted, “R‐G‐B”.   

6) Use a hacksaw or other appropriate metal saw with a minimum of 24 teeth/inch to cut the LED Strip along the LED Cut Line (Black in the photo). 

7)   After modifying the LED Strip to the appropriate length, use                  a file/wire brush to deburr and smooth the LED Strip                  modified end.   

8) Clean/shake out any debris from the inside of the strip.   

9) Install LED as previously detailed.   

 

Measure in this direction 

LED Cut Line In BLACK Cut LED  

Page 4: RGB Rigid Bar LED Light Strip MRI Compatible · the LED strip. 7) Ensure the LED strip is securely seated and raised from the surface. Wiring Diagram PDC LED Light Strips and fixtures

8165 E Kaiser Blvd. Anaheim, CA 92808p. 714.282.2270f. 714.676.5558

Test #: L05120601

Date: 5/10/2012

Test:

5/2/12

5/10/12 - 5/10/12

700 Walnut Ridge Dr. Hartland, WI 53029

Test Report: L05120601

Model Number:

Report Prepared For:

560-112

PDC FACILITIES, INC.

Equipment Used Model No Stock No Calibration Due Date

Electrical and Photometric tests as required by the IESNA test standards.

Standards Used: Appropriate part or all test guidelines were used for test performed:IESNA LM79: 2008 Approved Methods for Electrical and Photometric Measurements of Solid-State Lighting ProductsANSI NEMA ANSLG C78.377: 2008 Specification of the Chromaticity of Solid State Lighting Products

Description of Sample: Client submitted sample of RGB LED bar. Fixture catalog number is 560-112. Received in working and undamaged condition. No modifications were necessary.

Sample Arrival Date:

Date of Tests:

Seasoning of Sample SSL: No seasoning was performed in accordance with IESNA LM-79.

Equipment List

Chroma Programmable AC Source 61604 PS-AC02 --Yokogawa Digital Power Meter WT210 MT-EL06-S1 01/04/13Xitron Power Analysis System 2503AH MT-EL01 01/09/13Fluke Digital Thermometer 52k/J MT-TP02-GC 01/04/13LLI Type C Goniophotometer System RMG-C-MKII CD-LL04-GC --LLI 2M Sphere 2MR97 CD-SN03-S2 --LLI Spectroradiometer SPR-3000 MT-SC01-S2 Before Use

*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.

Page 1 of 4

Page 5: RGB Rigid Bar LED Light Strip MRI Compatible · the LED strip. 7) Ensure the LED strip is securely seated and raised from the surface. Wiring Diagram PDC LED Light Strips and fixtures

8165 E Kaiser Blvd. Anaheim, CA 92808p. 714.282.2270f. 714.676.5558

Test #: L05120601

Date: 5/10/2012

344.11

LM-79 Test Summary

Manufacturer:

Model Number:

Input Voltage (VDC): 12.00

PDC FACILITIES, INC.560-112

Total Lumens:

Input Current (Amp): 0.98

Input Power Factor: N.A.Efficacy: 29.17

Input Power (W): 11.80

Color Rendering Index (CRI): 17.20Correlated Color Temperature (CCT): 52600Chromaticity Coordinate x: 0.2641Chromaticity Coordinate y: 0.2274Ambient Temperature (

oF): 77.0

Stabilization Time (Hours): 0:47Total Operating Time (Hours): 1:07

*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.

Spectral Power Page 2 of 4

Page 6: RGB Rigid Bar LED Light Strip MRI Compatible · the LED strip. 7) Ensure the LED strip is securely seated and raised from the surface. Wiring Diagram PDC LED Light Strips and fixtures

8165 E Kaiser Blvd. Anaheim, CA 92808p. 714.282.2270f. 714.676.5558

Test #: L05120601

Date: 5/10/2012

Wavelength W/m2nm 440 0.0029 510 0.0068 580 0.0004 650 0.0010 720 -0.0001

380 -0.0002 450 0.0096 520 0.0081 590 0.0003 660 0.0003 730 0.0000

390 -0.0003 460 0.0202 530 0.0057 600 0.0004 670 -0.0001 740 0.0007

400 -0.0005 470 0.0141 540 0.0034 610 0.0029 680 0.0000 750 0.0005

410 0.0000 480 0.0070 550 0.0019 620 0.0089 690 -0.0002 760 -0.0002

420 0.0002 490 0.0036 560 0.0009 630 0.0179 700 0.0000 770 -0.0001

430 0.0007 500 0.0038 570 0.0006 640 0.0063 710 0.0001 780 -0.0001

CRI & CCT

x 0.2641

y 0.2274

u' 0.2032

v' 0.3935

CRI 17.20

CCT 52600

Duv 0.24657

R Values

R1 -16.04

R2 31.33

R3 69.05

R4 5.79

R5 12.31

R6 31.44

R7 49.23

R8 -45.55

R9 -339.53

R10 -54.58

R11 -14.46

R12 35.75

R13 -8.96

R14 74.33

*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.

430 440

460

470

480

490

500

510

520

530

540

550

560

570

580

590

600

610 620

630 640

650 700

380

0.2641, 0.2274

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9

CIE 1931 Chromaticity Diagram

X

Y

0.0

0.2

0.4

0.6

0.8

1.0

380 430 480 530 580 630 680 730 780 Wavelength(nm)

Spectral Power

Pe

rce

nt

Ou

tpu

t

Page 3 of 4

Page 7: RGB Rigid Bar LED Light Strip MRI Compatible · the LED strip. 7) Ensure the LED strip is securely seated and raised from the surface. Wiring Diagram PDC LED Light Strips and fixtures

8165 E Kaiser Blvd. Anaheim, CA 92808p. 714.282.2270f. 714.676.5558

Test #: L05120601

Date: 5/10/2012

Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization.

Test Methods

Photometric Measurements - Goniophotometer

A Custom Light Laboratory Type C Rotating Mirror Goniophotometer was used to measure candelas(intensity) at each angle of distribution as defined by IESNA for the appropriate fixture type.

Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization.

Electrical measurements are measured using the listed equipment.

Spectral Measurements - Integrating Sphere

A Sensing Spectroradiometer SPR-3000, in conjunction with Light Laboratory 2 meter integrating sphere was used to measure chromaticity coordinates, correlated color temperature(CCT) and the color rendering index(CRI) for each sample.

Engineering Manager Quality Assurance

*Attached are photometric data reports. Total number of pages: 10

*All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting.

Electrical measurements are measured using the listed equipment.

Test Report Released by: Test Report Reviewed by:

Joseph Shin Steve Kang

Page 4 of 4

Page 8: RGB Rigid Bar LED Light Strip MRI Compatible · the LED strip. 7) Ensure the LED strip is securely seated and raised from the surface. Wiring Diagram PDC LED Light Strips and fixtures

IES INDOOR REPORTPHOTOMETRIC FILENAME : L05120601.IES

DESCRIPTION INFORMATION (From Photometric File)

IESNA:LM-63-2002[TEST] L05120601[TESTLAB] LIGHT LABORATORY, INC.[ISSUEDATE] 5/10/12[MANUFAC] PDC FACILITIES[LUMCAT] 560-112[LUMINAIRE] 39-7/16"L. X 19/32"W. X 9/32"H. RGB LED BAR[MORE] 20 LED MODULES WITH 1-15/16" LENGTH[MORE] EACH MODULE HAS 3 RGB LEDS WITH 21/32" SPACING[MORE] 60 LEDS TOTAL[LAMPPOSITION] 0,0[LAMPCAT] RGB LED[OTHER] INDICATING THE CANDELA VALUES ARE ABSOLUTE AND[MORE] SHOULD NOT BE FACTORED FOR DIFFERENT LAMP RATINGS.[_POWER SUPPLY] 12VDC CONSTANT VOLTAGE SOURCE[_INPUT] 12VDC, 11.80W[_TEST PROCEDURE] IESNA:LM-79-08

CHARACTERISTICS

Lumens Per Lamp N.A. (absolute)Total Lamp Lumens N.A. (absolute)Luminaire Lumens 344Total Luminaire Efficiency N.A.Luminaire Efficacy Rating (LER) 29Total Luminaire Watts 11.8Ballast Factor 1.00CIE Type DirectSpacing Criterion (0-180) 1.34Spacing Criterion (90-270) 1.34Spacing Criterion (Diagonal) 1.48Basic Luminous Shape RectangularLuminous Length (0-180) 3.29 ftLuminous Width (90-270) 0.04 ftLuminous Height 0.00 ft

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.Calculations based on published IES Methods and recommendations, values rounded for display purposes.Results derived from content of manufacturers photometric file.

Page 1

Page 9: RGB Rigid Bar LED Light Strip MRI Compatible · the LED strip. 7) Ensure the LED strip is securely seated and raised from the surface. Wiring Diagram PDC LED Light Strips and fixtures

IES INDOOR REPORTPHOTOMETRIC FILENAME : L05120601.IES

LUMINANCE DATA (cd/sq.m)

Angle In Average Average AverageDegrees 0-Deg 45-Deg 90-Deg

45 9216 9304 913355 9472 9644 927865 9421 9619 911475 8430 8539 757885 5281 5316 2010

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.Calculations based on published IES Methods and recommendations, values rounded for display purposes.Results derived from content of manufacturers photometric file.

Page 2

Page 10: RGB Rigid Bar LED Light Strip MRI Compatible · the LED strip. 7) Ensure the LED strip is securely seated and raised from the surface. Wiring Diagram PDC LED Light Strips and fixtures

IES INDOOR REPORTPHOTOMETRIC FILENAME : L05120601.IES

CANDELA TABULATION

0.0 22.5 45.0 67.5 90.00 104.433 104.433 104.433 104.433 104.4335 104.344 104.264 104.265 104.161 103.77910 103.313 103.338 103.326 103.234 102.85715 101.926 101.918 101.876 101.814 101.32820 99.816 99.728 99.870 99.783 99.00225 97.016 96.979 97.124 96.996 96.17730 93.544 93.710 93.776 93.643 92.81335 89.681 89.834 89.971 89.793 88.74240 85.261 85.248 85.626 85.423 84.03145 79.745 80.102 80.509 80.181 79.03050 73.597 74.307 74.677 74.345 72.65055 66.486 67.080 67.695 67.308 65.12460 58.228 58.494 59.142 58.764 56.45065 48.724 49.426 49.750 49.372 47.13770 38.032 38.448 38.614 38.240 35.54075 26.701 26.688 27.045 26.701 24.00180 15.511 15.689 15.930 15.660 13.50885 5.633 5.766 5.670 3.942 2.14490 0.000 0.000 0.000 0.000 0.000

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.Calculations based on published IES Methods and recommendations, values rounded for display purposes.Results derived from content of manufacturers photometric file.

Page 3

Page 11: RGB Rigid Bar LED Light Strip MRI Compatible · the LED strip. 7) Ensure the LED strip is securely seated and raised from the surface. Wiring Diagram PDC LED Light Strips and fixtures

IES INDOOR REPORTPHOTOMETRIC FILENAME : L05120601.IES

ZONAL LUMEN SUMMARY

Zone Lumens %Lamp %Fixt

0-30 83.42 N.A. 24.200-40 139.59 N.A. 40.600-60 261.01 N.A. 75.900-90 344.11 N.A. 100.0090-120 0.00 N.A. 0.0090-130 0.00 N.A. 0.0090-150 0.00 N.A. 0.0090-180 0.00 N.A. 0.000-180 344.11 N.A. 100.00

Total Luminaire Efficiency = N.A.%

ZONAL LUMEN SUMMARY

Zone Lumens

0-10 9.9110-20 28.7720-30 44.7330-40 56.1840-50 61.7550-60 59.6660-70 48.2170-80 28.0680-90 6.8290-100 0.00100-110 0.00110-120 0.00120-130 0.00130-140 0.00140-150 0.00150-160 0.00160-170 0.00170-180 0.00

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.Calculations based on published IES Methods and recommendations, values rounded for display purposes.Results derived from content of manufacturers photometric file.

Page 4

Page 12: RGB Rigid Bar LED Light Strip MRI Compatible · the LED strip. 7) Ensure the LED strip is securely seated and raised from the surface. Wiring Diagram PDC LED Light Strips and fixtures

IES INDOOR REPORTPHOTOMETRIC FILENAME : L05120601.IES

COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD

Effective Floor Cavity Reflectance 0.20

RC 80 70 50 30 10 0RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0

0 119 119 119 119 116 116 116 116 111 111 111 106106106 102102102 1001 10810399 95 10510197 93 97 93 90 93 90 87 89 87 85 832 98 89 82 76 95 87 81 75 84 78 73 80 76 72 77 73 70 683 89 78 69 62 86 76 68 62 73 66 61 70 64 60 68 63 59 564 81 68 59 52 79 67 58 52 64 57 51 62 56 50 60 54 50 475 74 61 51 45 72 60 51 44 57 50 44 55 49 43 54 48 43 416 68 54 45 39 66 54 45 38 52 44 38 50 43 38 48 42 37 357 63 49 40 34 61 48 40 34 47 39 33 45 38 33 44 38 33 318 59 45 36 30 57 44 36 30 43 35 30 41 35 29 40 34 29 279 55 41 33 27 53 40 32 27 39 32 27 38 31 26 37 31 26 2410 51 38 30 24 50 37 29 24 36 29 24 35 29 24 34 28 24 22

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.Calculations based on published IES Methods and recommendations, values rounded for display purposes.Results derived from content of manufacturers photometric file.

Page 5

Page 13: RGB Rigid Bar LED Light Strip MRI Compatible · the LED strip. 7) Ensure the LED strip is securely seated and raised from the surface. Wiring Diagram PDC LED Light Strips and fixtures

IES INDOOR REPORTPHOTOMETRIC FILENAME : L05120601.IES

POLAR GRAPH

26

52

78

104

1

2

3

Maximum Candela = 104.433 Located At Horizontal Angle = 0, Vertical Angle = 0# 1 - Vertical Plane Through Horizontal Angles (0 - 180) (Through Max. Cd.): BLUE# 2 - Vertical Plane Through Horizontal Angles (90 - 270): MAGENTA # 3 - Horizontal Cone Through Vertical Angle (0) (Through Max. Cd.): RED

Photometric Toolbox Professional Edition - Copyright 2002-2011 by Lighting Analysts, Inc.Calculations based on published IES Methods and recommendations, values rounded for display purposes.Results derived from content of manufacturers photometric file.

Page 6