rf cannula - cosman medical€¦ · disposable electrode (tcd) straight sharp (cc101022) rf...

4
RF Cannula and Electrodes for Pain Management The Leader in RF Medicine Since 1952

Upload: vanhanh

Post on 06-Jul-2018

497 views

Category:

Documents


12 download

TRANSCRIPT

Page 1: RF Cannula - Cosman Medical€¦ · Disposable Electrode (TCD) Straight Sharp (CC101022) RF Electrodes Cosman cannula work with Nitinol, standard, and disposable thermocouple (TC)

RF Cannulaand Electrodes for Pain Management

The Leader in RF Medicine Since 1952

Page 2: RF Cannula - Cosman Medical€¦ · Disposable Electrode (TCD) Straight Sharp (CC101022) RF Electrodes Cosman cannula work with Nitinol, standard, and disposable thermocouple (TC)

Stan

dard

Ele

ctro

de (C

SK)

Curv

ed B

lunt

(RFK

-C10

1020

B)

Nitin

ol E

lect

rode

(TCN

)Cu

rved

Sha

rp (R

FK-C

1010

18S)

Disp

osab

le E

lect

rode

(TCD

)St

raig

ht S

harp

(CC1

0102

2)

RF ElectrodesCosman cannula work with Nitinol, standard, and disposable thermocouple (TC) electrodes of matching length and color.

Radiofrequency Cannula and Electrodes

20cm

15cm

10cm

5cm

Part # Length (cm) Tip (mm) Gauge (ga)

CC5422-P 5 4 22

CC5421-P 5 4 21

CC51021-P 5 10 21

CC10222-P 10 2 22

CC10522-P 10 5 22

CC10521-P 10 5 21

CC10520-P 10 5 20

CC10518-P 10 5 18

CC101022-P 10 10 22

CC101021-P 10 10 21

CC101020-P 10 10 20

CC101018-P 10 10 18

CC15520-P 15 5 20

CC15518-P 15 5 18

CC151020-P 15 10 20

CC151018-P 15 10 18

CC151520-P 15 15 20

CC20520-P 20 5 20

CC201020-P 20 10 20

Straight Sharp

Part # Length (cm) Tip (mm) Gauge (ga)

RFK-C5422S-P 5 4 22

RFK-C5616S-P 5 6 16

RFK-C51016S-P 5 10 16

RFK-C10522S-P 10 5 22

RFK-C10520S-P 10 5 20

RFK-C10518S-P 10 5 18

RFK-C10616S-P 10 6 16

RFK-C101022S-P 10 10 22

RFK-C101020S-P 10 10 20

RFK-C101018S-P 10 10 18

RFK-C101016S-P 10 10 16

RFK-C15520S-P 15 5 20

RFK-C15518S-P 15 5 18

RFK-C15616S-P 15 6 16

RFK-C151020S-P 15 10 20

RFK-C151018S-P 15 10 18

RFK-C151016S-P 15 10 16

RFK-C151520S-P 15 15 20

RFK-C20520S-P 20 5 20

RFK-C201020S-P 20 10 20

Curved Sharp

Page 3: RF Cannula - Cosman Medical€¦ · Disposable Electrode (TCD) Straight Sharp (CC101022) RF Electrodes Cosman cannula work with Nitinol, standard, and disposable thermocouple (TC)

Ground Pad(DGP-PM)

Cordless Ground Pad (DGP-PMC)

Standard

Gel media, GE® Venue™40 and 12L-SC ultrasound transducer.

EchoRF™

Part # Length (cm) Tip (mm) Gauge (ga) Shaft

CC5521U-P 5 5 21 Straight

CC10521U-P 10 5 21 Straight

CC101021U-P 10 10 21 Straight

CC15521U-P 15 5 21 Straight

CC151021U-P 15 10 21 Straight

EchoRF®

Ultrasound imaging allows direct imaging of nerves relative to the RF cannula. Echogenic RF cannula improve tip visibility compared with standard cannula.

Part # Length (cm) Tip (mm) Gauge (ga) Shaft

CC5422Z-P 5 4 22 Straight

CC10522Z-P 10 5 22 Straight

RFK-C10522SZ-P 10 5 22 Curved

RFK-C101022SZ-P 10 10 22 Curved

RFK-C101020SZ-P 10 10 20 Curved

RFK-C101018SZ-P 10 10 18 Curved

RFK-C151020SZ-P 15 10 20 Curved

RFK-C151018SZ-P 15 10 18 Curved

SiliconizedAll Cosman cannula have tapered insulation for smooth maneuvering. Siliconized models offer superior lubricity.

Part # Length (cm) Tip (mm) Gauge (ga) Feature

RFK-C10520B-P 10 5 20 Curved

RFK-C101020B-P 10 10 20 Curved

RFK-C15520B-P 15 5 20 Curved

RFK-C151020B-P 15 10 20 Curved

Blunt PointChoose blunt point cannula with side port for injection to suit your clinical needs.

Additional sizes may be available.

Premium Ground PadsDisposable pads specialized for RF pain management procedures. Available with integral/disposable or separate/reusable cables.

Standard

SideKick

Cannula Type & Tip Size

RF Ablation Size*

W (mm) L (mm) V (mm2)

Standard 20ga 10mm 5.1 ± .35 12.1 ± .34 179 ± 25

SideKick 20ga 10mm 7.9 ± .35 12.4 ± .51 392 ± 38

Part # Length (cm) Tip (mm) Gauge (ga) Feature

RFK-C101020S-ZK-P 10 10 20 Curved

RFK-C151020S-ZK-P 15 10 20 Curved

SideKick®

Increase ablation volume by 119%* without increasing cannula thickness. The SideKick® is a siliconized side-outlet cannula that is compatible with TCN electrodes only.

* Mean ± SD (n=8) extent of color change in porcine muscle ex vivo at 37°C, set temperature 80°C, set time 2:00, monopolar RF, Cosman G4 generator. Ellipsoidal volume V estimated from cross-sectional measurements. Ex vivo lesions may differ from clinical lesions.

Page 4: RF Cannula - Cosman Medical€¦ · Disposable Electrode (TCD) Straight Sharp (CC101022) RF Electrodes Cosman cannula work with Nitinol, standard, and disposable thermocouple (TC)

Rx Only. Read Instructions for Use before use. Some products not available in all countries.

Cosman Medical, Inc.22 Terry Avenue Burlington, MA USA 01803 SPI12482 Rev C 20160321

www.cosmanmedical.com

Tel: +1 781 272 6561 Fax: +1 781 272 6563 [email protected] © 2016 Cosman Medical, Inc.

Cosman Radiofrequency Electrodes

Cannula (CC, RFK)

~3 meter cable (CB112-TC)

Cosman G4 RF Generator

Electrode with 3-meter integrated cable (CSK-TC10-3M)

Electrode with 1-meter leader cable (CSK-TC10)

Nitinol Electrode (TCN)· “Memory” metal shaft

· Superior durability

· Compatible with SideKick cannula

· Autoclavable

Part # Length (cm) Cable

TCN-5 5 CB112-TC

TCN-5-3M 5 Integrated

TCN-10 10 CB112-TC

TCN-10-3M 10 Integrated

TCN-15 15 CB112-TC

TCN-15-3M 15 Integrated

TCN-20 20 CB112-TC

TCN-20-3M 20 Integrated

Standard Electrode (CSK)· Stainless steel shaft

· Reliable construction

· Cost-effective

· Autoclavable

Part # Length (cm) Cable

CSK-TC5 5 CB112-TC

CSK-TC5-3M 5 Integrated

CSK-TC10 10 CB112-TC

CSK-TC10-3M 10 Integrated

CSK-TC15 15 CB112-TC

CSK-TC15-3M 15 Integrated

CSK-TC20 20 CB112-TC

Disposable Electrode (TCD)· Sterile-packed for ease of use

· Eliminate sterilization logistics and costs

· Stock for mishaps and unusual schedules

· Eliminate the possibility of disease transmission

Part # Length (cm) Cable

TCD-5-P 5 CB114-TC

TCD-5-3M 5 Integrated

TCD-10-P 10 CB114-TC

TCD-10-3M 10 Integrated

TCD-15-P 15 CB114-TC

TCD-15-3M 15 Integrated

TCD-20-P 20 CB114-TC

Cannula (CC, RFK)