revolutionising the practice of refraction the first ever ......mkh 12 cowen test visionix 3d tests...

12
Revolutionising the practice of refraction The first EVER binocular dynamic exam

Upload: others

Post on 28-Feb-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Revolutionising the practice of refraction The first EVER ......MKH 12 Cowen test Visionix 3D tests Binocular immersive vision VX25 VX22 LP+ VX22 LP. This document is not contractual

Revolutionising the practice of refraction

The first EVER binocular dynamic exam

Page 2: Revolutionising the practice of refraction The first EVER ......MKH 12 Cowen test Visionix 3D tests Binocular immersive vision VX25 VX22 LP+ VX22 LP. This document is not contractual

Wavefront Technology

Visionix Has Developeda New Method of RefractionEye RefractTM developed by VISIONIX® is part of a complete and revolutionary refraction system that offers a rapid, binocu-lar and dynamic measurement using Wavefront Technology. Eye RefractTM is based on patented Wavefront Technology developed by Visionix®.

The system consists of a fully automatic VX40 lensmeter which integrates Wavefront technology, the complete VX22 chart display or the VX25 space saving chart, a tablet and the Eye Refract TM. These elements communicate via an independent WiFi signal.

Wavefront technology offers a measurement of the eye featuring a multitudeof analysed points based on the wavefront, whereas traditional technologies measure a single point or just a few points. Visionix® pioneered patented methods which miniaturised this technology.

After blurring, the patient experiences simultaneous binocular measurements and adjustments of the lenses to get the most perfect wavefront result.

2

Page 3: Revolutionising the practice of refraction The first EVER ......MKH 12 Cowen test Visionix 3D tests Binocular immersive vision VX25 VX22 LP+ VX22 LP. This document is not contractual

the full concept

3

Eye RefractTM allows you to perform a precise and repeatable dynamic binocular refraction in less than 3 minutes.

Binocular Vision

True addition takes into account real distance results. By adjusting the chart to the specific working distance for each patient, this gives maximum comfort and best near vision results.

Near Vision

Fully automatic lens analyser

Automatic Eye Tracking and focusing driven by the user via the tablet - this can be performed by anyone in the practice! Wireless Capability using

a Tablet Remotely

Distance Vision Measurement for small space

1

1

2

2Distance Vision Measurement for normal space

OR

Page 4: Revolutionising the practice of refraction The first EVER ......MKH 12 Cowen test Visionix 3D tests Binocular immersive vision VX25 VX22 LP+ VX22 LP. This document is not contractual

customer experience and comfort

4

the wow FACTORWith Eye RefractTM, the patient experiences transition from a blurry to a clear image almost immediately. The iteration cycles take only a few seconds. After blurring, the patient experiences simultaneous measurements and adjustments of the lenses to get the most perfect Wavefront measurement.

A new experience for the patient during their refraction exami-nation: after the Eye RefractTM dynamic measurement our new method of refraction is based on the comparison of eye test lines or sharp points, while the traditional methods ask the patients to compare blurry elements. This also the reason why the repeatability is twice as good with Eye Refract because our process generates/induces less subjectivity.

working with clear vision instead of blurred

Page 5: Revolutionising the practice of refraction The first EVER ......MKH 12 Cowen test Visionix 3D tests Binocular immersive vision VX25 VX22 LP+ VX22 LP. This document is not contractual

Automatic measurement VX40 LENS ANALYsER

DYNAMIC measurement Eye RefractTM

BEST USER EXPERIENCE

The VX40 combines automatism with a high precision of measurement and allows you to spend more time with your patients and less time trying to get an accurate analysis from their current spectacles. Just press one button and in a few seconds obtain a full mapping of the lenses (1350 points of measurement). VX40 automatically detects different types of lenses: progressives, single vision as well as bifocals. It is compatible with all lens technologies and brands.

Easy-to-use refractive instrument providing highly repeatable results, not dependant on the operator, patient or method used.

Advanced technology including: Auto-focus, Auto-tracking, simultaneous measurement. Both measurement and refraction verification at the same time. Full connectivity and data transfer (VX 40, VX 22 LP, PC).

5

DYNAMIC BINOCULAR MEASUREMENT

Page 6: Revolutionising the practice of refraction The first EVER ......MKH 12 Cowen test Visionix 3D tests Binocular immersive vision VX25 VX22 LP+ VX22 LP. This document is not contractual

6

Eye RefractTM utilises a unique and innovative technology which integrates an automatic refraction measurement and a simultaneous iterative lens adjustment. This instrument has revolutionised the practice of refraction offering quick, accurate, and reliable measurements. Eye RefractTM allows eye care professionals to optimise time spent with patients who have a complicated prescription, clinical needs or to discuss other commercial options such as contact lenses or night driving spectacles.

Perfect Visual Acuity in less than 3 minutes

More accurate prescription

Time Savings

Eye RefractTM allows you to perform a precise and repeatable dynamic binocular refraction in less than 3 minutes in comparison with a standard refraction which takes 8 to 10 minutes. Less time for refraction, more time to interact with your patients.

Drastically reduces waiting time and improves ultimate efficiency for your practice. More time to interact with your patients : dedicate more time for other clinical diagnostics or talk to the patient about their vision concerns.

Accuracy / Repeatability / Speed

Comfort zoneAccurate and reliable

prescriptions offer maximum comfort in less time to the patients. Reproducibility is more accurate than traditional refraction. Reduce costly remakes due to accuracy of results.

Page 7: Revolutionising the practice of refraction The first EVER ......MKH 12 Cowen test Visionix 3D tests Binocular immersive vision VX25 VX22 LP+ VX22 LP. This document is not contractual

7

EYE EXAMEye RefractTM offers you more than a prescription. Thanks to Eye RefractTM, you are able to have an auto-refracted reading of your patient’s day and night refraction which will allow you to understand their visual issues and adapt your prescriptions and recommendations accordingly.According to the patient’s issues and in addition to the refraction, you can perform an advanced eye exam using polarized tests, red/green tests, Jackson cross cylinders, prisms...

There is the potential to connect the eye refract to other devices

Additional tests to perform eye exam.

EHR/EMR

Customisable reports

Web services / referral platform

EMR

VX refraction line empowers your practice

Page 8: Revolutionising the practice of refraction The first EVER ......MKH 12 Cowen test Visionix 3D tests Binocular immersive vision VX25 VX22 LP+ VX22 LP. This document is not contractual

Standard space configuration WITH the new visionix VX22 LP CHART DISPLAY

VX22 LP

Eye Refract TM

VX40

TABLET

8

NEW configurationS adaptable to your Environment and SPACE

Mirror mode possibleProjection distance 2 to 8 metres Mirror mode possible

VX22 LINEAR POLARISED SCREEN CHART DISPLAYThis device features a linear polarisation to test binocular and stereoscopic vision allowing a perfect dissociation of the right eye/left eye. This offers the ability to proceed with many other tests with optimal quality for the examination of bi-ocular, binocular, and stereoscopic vision.

• New LCD display, with its 23.6” size • This screen has been designed for optimal results in the exam room • Ergonomic design • Streamlined style • Large number of tests including polarisation tests to use with

the polarised frame supplied with the chart displays

Page 9: Revolutionising the practice of refraction The first EVER ......MKH 12 Cowen test Visionix 3D tests Binocular immersive vision VX25 VX22 LP+ VX22 LP. This document is not contractual

VX25

Eye Refract TM

VX40

TABLET

9

VX25 SPACE SAVING CHARTThis screen has been designed for optimal results in the exam room pre screen area thanks to its ergonomic design, streamlined style, and the large number of tests included. This device is used for diagnostic purposes in ophthalmology, visual acuity and binocular vision testing.

• No obligation for a standard projection or with inverted mirrors • Almost natural conditions, projection to infinity minimises the accommodation.. • High contrast and natural head position. • The space saving chart has its own environment / independent lighting • Wide choice of acuity scales• Standard and regular tests (regular spacing between letters) • Effective anti-reflection coating, black matt screen

SAVING SPACE CONFIGURATION

configurationS adaptable to your Environment and SPACE

SPACE SAVING CONFIGURATION WITH the new visionix VX25 SPACE SAVING CHART

Working distance 0.8 meter

0,5 m2

Intended use: device used for diagnostic purposes in ophthalmology, visual acuity and binocular vision testing. - Medical device CE Class I For health professionals - Read the instructions in the user manual carefully. - Manufacturer: Luneau Technology Operations - 04/19

80 cm

Page 10: Revolutionising the practice of refraction The first EVER ......MKH 12 Cowen test Visionix 3D tests Binocular immersive vision VX25 VX22 LP+ VX22 LP. This document is not contractual

10

More accurate prescription

DELEGATION & Time Savings

Perfect Visual Acuity in less than 3 minutes

Accurate and reliable prescriptions offer maximum comfort in less time to the patient

The ultimate efficiency for your practice

Less dedicated time for refraction, more time to interact with your patients

Before Eye Refract TM

Before Eye Refract TM

Before Eye Refract TM

With Eye Refract TM

With Eye Refract TM

With Eye Refract TM

Subjective answers from the patient = Uncertainty of the results

Longer waiting times for patients

The average time of a standard refraction is 8 to 10 minutes

Real time lens adjustment based on the patients brain reaction

Drastic reduction of waiting time

Achieve binocular refraction in less than 3 minutes

EYE REFRACT TM THE NEW REFERENCE

Page 11: Revolutionising the practice of refraction The first EVER ......MKH 12 Cowen test Visionix 3D tests Binocular immersive vision VX25 VX22 LP+ VX22 LP. This document is not contractual

11

Large range of optotypes and tests

Letter Digit Landolts rings Snellen Kids Geometric Learning Pic

Amsler Sheridan ETDRS Astigmatism Dot chart Jackson Cross Ishihara

Kids Movie Polarised balance Red green balance Steroscopy Mallet test Fusion Worth tests

Schober test Pelli Robson Regan test Dazzle halo Dazzle driver Dazzle recup

Pola binocular balance

Binocular duochrome polarised

Binocular duochrome polarised

MKH 01 Cross MKH02 indicator MKH 03 double indicator

MKH 03 conicidence test

MKH 05 Stereo test with triangle

MKH 06 reduce stereo test with triangle

MKH 07 stereo balance test

MKH08 reduced stereo balance test

MKH09 differential test

MKH09 differential test B

MKH 12 Cowen test

Visionix 3D tests Binocular immersive vision

VX25 VX22 LP+

VX22 LP

Page 12: Revolutionising the practice of refraction The first EVER ......MKH 12 Cowen test Visionix 3D tests Binocular immersive vision VX25 VX22 LP+ VX22 LP. This document is not contractual

This

docu

ment

is n

ot co

ntra

ctual

- Con

cept

ion K

OSEP

T - ©

Phot

os :

Eric

Bien

venu

/ Br

iot -

FC00

905

- ind

02-0

9/19

The

Eye

Refra

ct is

a co

mput

erize

d ph

orop

ter t

hat c

an b

e us

ed b

y eye

-care

pro

fess

ionals

to d

eter

mine

pat

ients’

requ

ired

refra

ctive

corre

ction

. The

mac

hine

pr

oduc

es a

n ini

tial w

avef

ront

esti

mate

of t

he p

atien

t’s re

fracti

on, a

nd e

nable

s the

pra

ctitio

ner t

o co

mplet

e th

e pr

escri

ption

thro

ugh

a tra

dition

al su

bjecti

ve te

st.

LUNEAU TECHNOLOGY OPERATIONS2 rue Roger Bonnet, 27340 PONT DE L’ARCHE - FRANCE Tel. + 33 232 989 132 - Fax + 33 235 020 294 - www.luneautech.com

Dimensions 2 VX25 space saving chart

H 660 mm (25,98 in.) x W 320 mm (12,60 in.) x D 325 mm (12,79 in.) Weight 25 Kg (55.12 Lbs)

VX40 Wavefront analyser H 455 mm (17,90 in.) x W 220 mm (8,66 in.) x D 240 mm (9,44 in.) Weight 9 kg (20 lbs)

4 Eye Refract Table Adjustable height side from 675 to 925 mm (26.57 to 36.42 inc. ) x W 1090 (42,91 in.) x D 460 mm (18,11 in.) Weight 38,5 Kgs (83.78 lbs)

5 VX40 console H828 mm (32,60 in.)x W 320 mm (12,60 in.) x D 359 mm (14,13 in.)

• Eye RefractTM

• VX22 LP• VX40• Table VX40-ER

30230000-008241-0022-403014-0000-008160-0025-00

configurations

REF.

• Eye RefractTM

• VX25• VX40• Console VX40• Table VX25-ER

30230000-008225-0000-003014-0000-008160-8025-00 8160-0025-00

REF.

EYE REFRACTTM

Output • RS232 / USB2.0 / VGA / LAN• Embedded bluetooth / Wifi

Hardware Tablet ...............................................................AndroidChinrest ...........................................................ElectricalNear Vision Target .......................................... 250-700 mm

Mini tablet 7“Head ................................................................Autofocus, autocentering

Range Sph ..................................................................-30,00D to +27,25D Sph step ..........................................................0,125 / 0,25 / 0,50 / 1 DCyl....................................................................-6,00 to +6,00 DCyl step ...........................................................0,25 / 0,50 / 1 DOptical axis .....................................................0 to 180°Axis step .........................................................1° / 5° / 10° / 45°Prisms ..............................................................0 to 20 D

Communication

Technical Specifications

TM

Height 490 mm (19,3 in)

Width 290 mm (11,4 in)

Depth 470 mm (18,5 in)

Weight 25 kg (55 lbs)

Power100/120, 220/240 V AC, 50/60 Hz

Voltage230 V 50 / 60 Hz

1 21

2

3

4

3

Dimensions 2 VX22 chart display

H 380 mm (14,96 in.) x W 585 mm (23,03 in.) x D 46 mm (1,81 in.) - Weight 3,8 Kg (8, 38Lbs)

3 VX40 Wavefront analyser H 455 mm (17,90 in.) x W 220 mm (8,66 in.) x D 240 mm (9,44 in.) Weight 9 kg (20 lbs)

4 Eye Refract table Adjustable height side from 675 to 925 mm (26.57 to 36.42 inc. ) x W 1090 (42,91 in.) x D 460 mm (18,11 in.) Weight 38,5 Kgs (83.78 lbs)

1 2 3

5

4