Revolutionising the practice of refraction
The first EVER binocular dynamic exam
Wavefront Technology
Visionix Has Developeda New Method of RefractionEye RefractTM developed by VISIONIX® is part of a complete and revolutionary refraction system that offers a rapid, binocu-lar and dynamic measurement using Wavefront Technology. Eye RefractTM is based on patented Wavefront Technology developed by Visionix®.
The system consists of a fully automatic VX40 lensmeter which integrates Wavefront technology, the complete VX22 chart display or the VX25 space saving chart, a tablet and the Eye Refract TM. These elements communicate via an independent WiFi signal.
Wavefront technology offers a measurement of the eye featuring a multitudeof analysed points based on the wavefront, whereas traditional technologies measure a single point or just a few points. Visionix® pioneered patented methods which miniaturised this technology.
After blurring, the patient experiences simultaneous binocular measurements and adjustments of the lenses to get the most perfect wavefront result.
2
the full concept
3
Eye RefractTM allows you to perform a precise and repeatable dynamic binocular refraction in less than 3 minutes.
Binocular Vision
True addition takes into account real distance results. By adjusting the chart to the specific working distance for each patient, this gives maximum comfort and best near vision results.
Near Vision
Fully automatic lens analyser
Automatic Eye Tracking and focusing driven by the user via the tablet - this can be performed by anyone in the practice! Wireless Capability using
a Tablet Remotely
Distance Vision Measurement for small space
1
1
2
2Distance Vision Measurement for normal space
OR
customer experience and comfort
4
the wow FACTORWith Eye RefractTM, the patient experiences transition from a blurry to a clear image almost immediately. The iteration cycles take only a few seconds. After blurring, the patient experiences simultaneous measurements and adjustments of the lenses to get the most perfect Wavefront measurement.
A new experience for the patient during their refraction exami-nation: after the Eye RefractTM dynamic measurement our new method of refraction is based on the comparison of eye test lines or sharp points, while the traditional methods ask the patients to compare blurry elements. This also the reason why the repeatability is twice as good with Eye Refract because our process generates/induces less subjectivity.
working with clear vision instead of blurred
Automatic measurement VX40 LENS ANALYsER
DYNAMIC measurement Eye RefractTM
BEST USER EXPERIENCE
The VX40 combines automatism with a high precision of measurement and allows you to spend more time with your patients and less time trying to get an accurate analysis from their current spectacles. Just press one button and in a few seconds obtain a full mapping of the lenses (1350 points of measurement). VX40 automatically detects different types of lenses: progressives, single vision as well as bifocals. It is compatible with all lens technologies and brands.
Easy-to-use refractive instrument providing highly repeatable results, not dependant on the operator, patient or method used.
Advanced technology including: Auto-focus, Auto-tracking, simultaneous measurement. Both measurement and refraction verification at the same time. Full connectivity and data transfer (VX 40, VX 22 LP, PC).
5
DYNAMIC BINOCULAR MEASUREMENT
6
Eye RefractTM utilises a unique and innovative technology which integrates an automatic refraction measurement and a simultaneous iterative lens adjustment. This instrument has revolutionised the practice of refraction offering quick, accurate, and reliable measurements. Eye RefractTM allows eye care professionals to optimise time spent with patients who have a complicated prescription, clinical needs or to discuss other commercial options such as contact lenses or night driving spectacles.
Perfect Visual Acuity in less than 3 minutes
More accurate prescription
Time Savings
Eye RefractTM allows you to perform a precise and repeatable dynamic binocular refraction in less than 3 minutes in comparison with a standard refraction which takes 8 to 10 minutes. Less time for refraction, more time to interact with your patients.
Drastically reduces waiting time and improves ultimate efficiency for your practice. More time to interact with your patients : dedicate more time for other clinical diagnostics or talk to the patient about their vision concerns.
Accuracy / Repeatability / Speed
Comfort zoneAccurate and reliable
prescriptions offer maximum comfort in less time to the patients. Reproducibility is more accurate than traditional refraction. Reduce costly remakes due to accuracy of results.
7
EYE EXAMEye RefractTM offers you more than a prescription. Thanks to Eye RefractTM, you are able to have an auto-refracted reading of your patient’s day and night refraction which will allow you to understand their visual issues and adapt your prescriptions and recommendations accordingly.According to the patient’s issues and in addition to the refraction, you can perform an advanced eye exam using polarized tests, red/green tests, Jackson cross cylinders, prisms...
There is the potential to connect the eye refract to other devices
Additional tests to perform eye exam.
EHR/EMR
Customisable reports
Web services / referral platform
EMR
VX refraction line empowers your practice
Standard space configuration WITH the new visionix VX22 LP CHART DISPLAY
VX22 LP
Eye Refract TM
VX40
TABLET
8
NEW configurationS adaptable to your Environment and SPACE
Mirror mode possibleProjection distance 2 to 8 metres Mirror mode possible
VX22 LINEAR POLARISED SCREEN CHART DISPLAYThis device features a linear polarisation to test binocular and stereoscopic vision allowing a perfect dissociation of the right eye/left eye. This offers the ability to proceed with many other tests with optimal quality for the examination of bi-ocular, binocular, and stereoscopic vision.
• New LCD display, with its 23.6” size • This screen has been designed for optimal results in the exam room • Ergonomic design • Streamlined style • Large number of tests including polarisation tests to use with
the polarised frame supplied with the chart displays
VX25
Eye Refract TM
VX40
TABLET
9
VX25 SPACE SAVING CHARTThis screen has been designed for optimal results in the exam room pre screen area thanks to its ergonomic design, streamlined style, and the large number of tests included. This device is used for diagnostic purposes in ophthalmology, visual acuity and binocular vision testing.
• No obligation for a standard projection or with inverted mirrors • Almost natural conditions, projection to infinity minimises the accommodation.. • High contrast and natural head position. • The space saving chart has its own environment / independent lighting • Wide choice of acuity scales• Standard and regular tests (regular spacing between letters) • Effective anti-reflection coating, black matt screen
SAVING SPACE CONFIGURATION
configurationS adaptable to your Environment and SPACE
SPACE SAVING CONFIGURATION WITH the new visionix VX25 SPACE SAVING CHART
Working distance 0.8 meter
0,5 m2
Intended use: device used for diagnostic purposes in ophthalmology, visual acuity and binocular vision testing. - Medical device CE Class I For health professionals - Read the instructions in the user manual carefully. - Manufacturer: Luneau Technology Operations - 04/19
80 cm
10
More accurate prescription
DELEGATION & Time Savings
Perfect Visual Acuity in less than 3 minutes
Accurate and reliable prescriptions offer maximum comfort in less time to the patient
The ultimate efficiency for your practice
Less dedicated time for refraction, more time to interact with your patients
Before Eye Refract TM
Before Eye Refract TM
Before Eye Refract TM
With Eye Refract TM
With Eye Refract TM
With Eye Refract TM
Subjective answers from the patient = Uncertainty of the results
Longer waiting times for patients
The average time of a standard refraction is 8 to 10 minutes
Real time lens adjustment based on the patients brain reaction
Drastic reduction of waiting time
Achieve binocular refraction in less than 3 minutes
EYE REFRACT TM THE NEW REFERENCE
11
Large range of optotypes and tests
Letter Digit Landolts rings Snellen Kids Geometric Learning Pic
Amsler Sheridan ETDRS Astigmatism Dot chart Jackson Cross Ishihara
Kids Movie Polarised balance Red green balance Steroscopy Mallet test Fusion Worth tests
Schober test Pelli Robson Regan test Dazzle halo Dazzle driver Dazzle recup
Pola binocular balance
Binocular duochrome polarised
Binocular duochrome polarised
MKH 01 Cross MKH02 indicator MKH 03 double indicator
MKH 03 conicidence test
MKH 05 Stereo test with triangle
MKH 06 reduce stereo test with triangle
MKH 07 stereo balance test
MKH08 reduced stereo balance test
MKH09 differential test
MKH09 differential test B
MKH 12 Cowen test
Visionix 3D tests Binocular immersive vision
VX25 VX22 LP+
VX22 LP
This
docu
ment
is n
ot co
ntra
ctual
- Con
cept
ion K
OSEP
T - ©
Phot
os :
Eric
Bien
venu
/ Br
iot -
FC00
905
- ind
02-0
9/19
The
Eye
Refra
ct is
a co
mput
erize
d ph
orop
ter t
hat c
an b
e us
ed b
y eye
-care
pro
fess
ionals
to d
eter
mine
pat
ients’
requ
ired
refra
ctive
corre
ction
. The
mac
hine
pr
oduc
es a
n ini
tial w
avef
ront
esti
mate
of t
he p
atien
t’s re
fracti
on, a
nd e
nable
s the
pra
ctitio
ner t
o co
mplet
e th
e pr
escri
ption
thro
ugh
a tra
dition
al su
bjecti
ve te
st.
LUNEAU TECHNOLOGY OPERATIONS2 rue Roger Bonnet, 27340 PONT DE L’ARCHE - FRANCE Tel. + 33 232 989 132 - Fax + 33 235 020 294 - www.luneautech.com
Dimensions 2 VX25 space saving chart
H 660 mm (25,98 in.) x W 320 mm (12,60 in.) x D 325 mm (12,79 in.) Weight 25 Kg (55.12 Lbs)
VX40 Wavefront analyser H 455 mm (17,90 in.) x W 220 mm (8,66 in.) x D 240 mm (9,44 in.) Weight 9 kg (20 lbs)
4 Eye Refract Table Adjustable height side from 675 to 925 mm (26.57 to 36.42 inc. ) x W 1090 (42,91 in.) x D 460 mm (18,11 in.) Weight 38,5 Kgs (83.78 lbs)
5 VX40 console H828 mm (32,60 in.)x W 320 mm (12,60 in.) x D 359 mm (14,13 in.)
• Eye RefractTM
• VX22 LP• VX40• Table VX40-ER
30230000-008241-0022-403014-0000-008160-0025-00
configurations
REF.
• Eye RefractTM
• VX25• VX40• Console VX40• Table VX25-ER
30230000-008225-0000-003014-0000-008160-8025-00 8160-0025-00
REF.
EYE REFRACTTM
Output • RS232 / USB2.0 / VGA / LAN• Embedded bluetooth / Wifi
Hardware Tablet ...............................................................AndroidChinrest ...........................................................ElectricalNear Vision Target .......................................... 250-700 mm
Mini tablet 7“Head ................................................................Autofocus, autocentering
Range Sph ..................................................................-30,00D to +27,25D Sph step ..........................................................0,125 / 0,25 / 0,50 / 1 DCyl....................................................................-6,00 to +6,00 DCyl step ...........................................................0,25 / 0,50 / 1 DOptical axis .....................................................0 to 180°Axis step .........................................................1° / 5° / 10° / 45°Prisms ..............................................................0 to 20 D
Communication
Technical Specifications
TM
Height 490 mm (19,3 in)
Width 290 mm (11,4 in)
Depth 470 mm (18,5 in)
Weight 25 kg (55 lbs)
Power100/120, 220/240 V AC, 50/60 Hz
Voltage230 V 50 / 60 Hz
1 21
2
3
4
3
Dimensions 2 VX22 chart display
H 380 mm (14,96 in.) x W 585 mm (23,03 in.) x D 46 mm (1,81 in.) - Weight 3,8 Kg (8, 38Lbs)
3 VX40 Wavefront analyser H 455 mm (17,90 in.) x W 220 mm (8,66 in.) x D 240 mm (9,44 in.) Weight 9 kg (20 lbs)
4 Eye Refract table Adjustable height side from 675 to 925 mm (26.57 to 36.42 inc. ) x W 1090 (42,91 in.) x D 460 mm (18,11 in.) Weight 38,5 Kgs (83.78 lbs)
1 2 3
5
4