revisions / amendments child care centreprojectcorp.com.au/wordpress/projectfiles/child care...
TRANSCRIPT
CHILD CARE CENTRE 823-825 BOTANY ROAD, ROSEBERY, NSW 2018
HYDRAULIC SERVICES
OFG
WM
GM
BT
DTU
SMH
TD
HYDRAULIC LEGEND
INDICATES PIPE RISERS
INDICATES SERVICE TYPE.
INDICATES SERVICE SIZE.
EXISTING SERVICES IDENTIFICATION.
DROPPER / RISER / SIZE.
SYSTEM ACCESSORIES LEGENDCLEAROUT (CO).
SEWER INSPECTION SHAFT
UNION.
PIPELINE CAPPED OFF.
FLANGED JOINT.
OVERFLOW GULLY.
WATER METER
GAS METER.
BOUNDARY TRAP.
DRAINAGE OUTLET.
BTFW - BUCKET TRAP FLOOR WASTE
FW - FLOOR WASTE
PDO - PLANTER DRAIN OUTLET
RWO - RAIN WATER OUTLET
VFW - VINYL FLOOR WASTE
PD - PLANTER DRAIN
CO
DRAINAGE TURN-UP.
MANHOLE.
SMH - SEWERAGE MANHOLE
SWMH - STORMWATER MANHOLE
STORMWATER PIT WITH SEALED COVER.
STORMWATER PIT WITH GRATE.
EXISTING STORMWATER PIT.
STORMWATER SPREADER.
PENETRATION CORE THROUGH STRUCTURAL ELEMENT.
INDUCT PIPE MICA FLAP.
NEW JUNCTION INTO EXISTING PIPELINE
NEW BRANCH INTO EXISTING PIPELINE.
GRATED DRAIN.
TUNDISH.
OVERLAND FLOW PATH.
GENERAL NOTES1. THIS PLAN MUST NOT BE COPIED OR REPRODUCED IN ANY FORM OR USED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED
WITHOUT APPROVAL FROM JHA CONSULTING ENGINEERS.
2. THIS PLAN SHALL BE READ IN CONJUNCTION WITH ALL ARCHITECTURAL, OTHER CONSULTANTS DRAWINGS, SPECIFICATIONS AND WITH
SUCH OTHER WRITTEN INSTRUCTIONS AS MAYBE ISSUED DURING THE COURSE. REFERRED TO THE ARCHITECT FOR DECISION BEFORE
PROCEEDING WITH THE WORK.
3. ALL WORKS TO BE IN ACCORDANCE WITH THE HYDRAULIC SERVICES SPEC, AUTHORITIES REQUIREMENTS, AS-3500, AS5601, AS 2444,
AS 2419, AS 2118.1, AS2441, AS1530, CURRENT NCC VOLUMES 1, 2 & 3.
4. CONFIRM LOCATION SIZE AND LEVELS OF ALL EXISTING SERVICES PRIOR TO COMMENCEMENT OF WORK.
5. DISCONNECT AND REMOVE ALL EXISTING REDUNDANT SERVICES TO AUTHORITIES APPROVAL.
6. LOCATIONS & FIXING OF PIPEWORK SHALL BE SUBJECT TO COORDINATION WITH OTHER DESIGN DISCIPLINES, ie STRUCTURAL,
MECHANICAL, ELECTRICAL AND OTHER SERVICES ENGINEERS.
7. ALL LOCATIONS OF EXISTING SERVICES MAINS TO BE CONFIRMED BY MEANS OF DIAL BEFORE YOU DIG, PIPE LOCATOR AND TRACING.
8. PRIOR TO COMMENCEMENT OF WORKS.ALL WORKS TO INCLUDE TESTING, INSPECTIONS, OBTAINING REQUIRED CERTIFICATES ON
COMPLETION & PAYMENT OF RELEVANT FEES.
9. THE HYDRAULIC CONTRACTOR SHALL ALLOW IN THE TENDER TO SUBMIT PHOTO BASED INSPECTION AND TEST PLANS ESPECIALLY
FOR SERVICE PENETRATIONS THROUGH FIRE AND SMOKE WALLS. REFER TO ARCHITECTURAL DRAWINGS FOR DEMOLITION PLAN AND
SCOPE OF WORKS.
10. ALLOW TO CLEAN / FLUSH OUT ALL EXISTING STORMWATER DRAINAGE.
11. ALLOW TO SAWCUT/REMOVE HARD SURFACES AREAS AS REQUIRED TO COMPLETE THE INSTALLATION. ALLOW TO MAKE GOOD
SURFACES UPON COMPLETION.
12. CHECK EXISTING ELECTRICAL EARTHING TO METALLIC PLUMBING SERVICES. PROVIDE TEMPORARY EARTHING CABLES BETWEEN
SERVICES, WHICH ARE TO BE CUT, TERMINATED OR EXTENDED. CONFIRM WITH SITE ELECTRICIAN FOR SAFE PROCEDURES.
13. CONTRACTOR IS TO SET OUT & DIMENSION ALL PENETRATIONS & GAIN APPROVAL FROM STRUCTURAL ENGINEER BEFORE WORK
COMMENCES. PROVIDE SEPARATE PENETRATION FOR EACH SERVICE SO AS TO ENSURE ADEQUATE FIRE STOPPING. ALL PIPE
PENETRATIONS SHALL BE FITTED WITH APPROVED FIRE STOP COLLARS/ DEVICES TO CONFORM TO AS1530.
14. WATER, WASTE & GAS PIPES LOCATED WITHIN JOINERY CABINETS, SINK CUPBOARD etc. SHALL BE ARRANGED IN A MANNER SO AS NOT
TO OBSTRUCT THE FREE SPACE AS FAR AS PRACTICAL INSTALLATION PERMITS.
15. THE DOCUMENTS REPRESENT DESIGN CONCEPT ONLY. IT IS THE SUB CONTRACTORS RESPONSIBILITY TO DEVELOP DETAILED
DRAWINGS, FULLY COORDINATED WITH ALL SERVICE DISCIPLINES, NEW AND EXISTING STRUCTURE AND ARCHITECTURAL
DOCUMENTATION.
16. THE SUB CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE DETAILED DESIGN, CALCULATIONS AND SUBMISSIONS, SUPPLY AND
INSTALLATION OF ALL SERVICES, CERTIFICATION AND APPROVALS, COMMISSIONING, TESTING & HANDOVER.
17. THE SUB CONTRACTOR IS TO ALLOW FOR THE PAYMENT OF ALL FEES AND CHARGES LEVIED BY THE VARIOUS AUTHORITIES AND
PREPARE ALL SUBMISSIONS, AS REQUIRED TO FACILITATE THE CONSTRUCTION OF ALL SERVICES.
18. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN.
19. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS NOTED OTHERWISE.
20. ALL DIMENSIONS SHALL BE VERIFIED ON SITE BEFORE PROCEEDING WITH THE WORK. THE CLIENT SHALL BE NOTIFIED IN WRITING OF
ANY DISCREPANCIES.
DRAWING LISTH000 - COVER SHEET, LEGEND OF SYMBOLS, SITE PLAN, GENERAL NOTES & DRAWING LIST .
H100 - GROUND FLOOR - SANITARY & STORMWATER DRAINAGE LAYOUT
H101 - LEVEL 1 - SANITARY & STORMWATER DRAINAGE LAYOUT
H102 - ROOF PLAN
H200 - GROUND FLOOR - WATER & GAS SERVICES LAYOUT
H201 - LEVEL 1 - WATER & GAS SERVICES LAYOUT
H300 - GROUND FLOOR - DEMOLITION PLAN
H301 - LEVEL 1 - DEMOLITION PLAN
H400 - DETAIL SHEET 1
H400 - DETAIL SHEET 2
H500 - GROUND FLOOR - FIRE HYDRANT & FIRE HOSE REEL RUN OF HOSE
H501 - LEVEL 1 - FIRE HYDRANT & FIRE HOSE REEL RUN OF HOSE
DESIGN ZONES
GENERAL ABBREVIATIONSAAV - AIR ADMITTANCE VALVE
AFFL - ABOVE FINISHED FLOOR LEVEL
ASTs - ANGLE STOP TAPS
B - BASINBB - BABY BATH
BG - BOX GUTTER
BT - BOUNDARY TRAP
CO - CLEAROUT
CP - CHROME PLATED
CR SK - CRAFT SINK
CS - CLEANERS SINK
CV - CHAMBER VENT
CW - COLD WATER
D - DRAINAGE
DHB - DISABLED PERSONS HANDWASH BASIN
DP - DOWNPIPE
DTU - DRAINAGE TURN-UP
DW - DISHWASHING MACHINE
DWC - DISABLED PERSONS WATER CLOSET
DWG No.- DRAWING NUMBER
DWV - DRAINAGE WASTE AND VENT
EG - EAVES GUTTER
EJ - EXPANSION JOINT
EX - EXISTING
FFL - FINISHED FLOOR LEVEL
FGL - FINISHED GROUND LEVELFH - FIRE HYDRANT
FHBV - FIRE HYDRANT BOOSTER VALVE
FHR - FIRE HOSE REEL
FU - FIXTURE UNIT
FW - FLOOR WASTE
G - GAS
GD - GRATED DRAIN
GL - GROUND LEVEL
GO - GUTTER OUTLET
HP - HIGH POINT
HL - HIGH LEVEL
HR - HALF ROUND
HT - HOSE TAP
HW - HOT WATER
HWF - HOT WATER FLOW
HWH - HOT WATER HEATER
HWR - HOT WATER RETURN
HWU - HOT WATER UNIT
IS - INSPECTION SHAFT
IL - INVERT LEVEL
IO - INSPECTION OPENING
JHB - JUNIOR HAND BASIN
JWC - JUNIOR WATER CLOSET
KS - KITCHEN SINK
LT - LAUNDRY TUBNo. - NUMBER
OF - OVERFLOW
OFG - OVERFLOW GULLY
PCW - POTABLE COLD WATER
RL - REDUCED LEVEL
RPZD - REDUCED PRESSURE ZONE DEVICE
RWH - RAIN WATER HEAD
RWO - RAINWATER OUTLETRV - RELIEF VENT
SEW - SEWER
SHR - SHOWER
SK - SINK
SMH - SEWER MANHOLE
SSL - STRUCTURAL SLAB LEVEL
ST - SANITARY/DRAINAGE STACK
SW - STORM WATER
SWP - STORM WATER PIT
TD - TUNDISH
TTD - TRAPPED TUNDISH
TTG - TRENCH GRATE
TYP - TYPICAL
U/G - UNDERGROUND
U/F - UNDER FLOOR
UNO - UNLESS NOTED OTHERWISE
VB - VANITY BASIN
VBTFW - VINYL BASKET TRAP FLOOR WASTE
VFW - VINYL FLOOR WASTEVP - VENT PIPE
WC - WATER CLOSET
WM - WASHING MACHINEWME - WATER METER
WP - WASTE PIPE
WP - WASH THROUGHWW - WARM WATER
Ø - DIAMETER
VALVE ABBREVIATIONSAP - ACCESS PANEL
CV - CHECK VALVE
FHV - FIRE HYDRANT VALVE
BV - BALL VALVE
HT - HOSE TAP
NRV - NON RETURN VALVE
PRV - PRESSURE REDUCTION VALVE
RPZD - REDUCED PRESSURE ZONE DEVICERV - REFLUX VALVE
SV - STOP VALVE
TEV - TEMPERING VALVE
TMV - THERMOSTATIC MIXING VALVE
TPR - TEMPERATURE AND PRESSURE RELIEF VALVE
SYSTEM ACCESSORIES LEGENDBALL VALVE.
GAS REGULATOR.
REDUCED PRESSURE ZONE DEVICE.
PRESSURE GAUGE AND GAUGE VALVE.
RELIEF OR SAFETY VALVE AND DRAIN.
AIR ADMITTANCE VALVE.
BASIN, SINK, SHOWER OR BATH TAP SET.
HOSE TAP.
THERMOSTATIC MIXING VALVE/VALVE CONTROL GROUP
WATER METER ASSEMBLY.
GAS METER ASSEMBLY.
RISER.
DROPPER.
TEE DROPPER.
HOT WATER UNIT.
HOT WATER PUMP SET.
FLUID FLOW AND MATERIAL ABBREVIATIONSAHD - AUSTRALIAN HEIGHT DATUM
Br - BRASS
CI - CAST IRON
CICL - CAST IRON CEMENT LINED
Cu - COPPER
DICL - DUCTILE IRON CEMENTED LINE
HDPE - HIGH DENSITY POLYETHYLENE
ID - INSIDE DIAMETER
kPa - PRESSURE IN KILOPASCALS
kW - KILOWATT
L - LITRES
L/s - FLOW IN LITRES PER SECOND
mm - MILLIMETRES
m - METRES
m² - METRES SQUARES
MJ - MEGAJOULE
M/s - VELOCITY OF FLOW IN METRES PER SECOND
mHD - PRESSURE IN METRES HEAD
OD - OUTSIDE DIAMETER
uPVC - UNPLASTICISED POLYVINYL CHLORIDE
VCP - VITRIFIED CLAY PIPE
IN THE STRATA OUT OF STRATA
SERVICES SHOWN ON THIS
DRAWING ARE ABOVE SLAB
SERVICES SHOWN ON THIS
DRAWING ARE BELOW SLAB
COLD WATER SERVICE.
HOT WATER FLOW.
WARM WATER SERVICE.
FIRE HYDRANT SERVICE.
HOT WATER RETURN.
NATURAL GAS SERVICE.
EXISTING SERVICE.
AERIAL DRAINAGE & SANITARY PLUMBING.
VENT PIPE.
STORMWATER DRAINAGE.
SEWER DRAINAGE.
ELECTRICAL SERVICE.
INDICATES SERVICE TYPE.
INDICATES SERVICE SIZE.
INDICATES PIPE DROPPERS
SWP
SWP
exSWP
FOR CONTINUATION REFER
DRAWING No. H-...
BV
GR
RPZD
PPG
RV
AAV
WW
e
EXISTING COLD WATER SERVICE.
EXISTING HOT WATER SERVICE.
EXISTING FIRE HYDRANT SERVICE.
EXISTING GAS SERVICE.
EXISTING SEWER SERVICE.
EXISTING VENT PIPE.
EXISTING STORMWATER DRAINAGE.
PIPELINE CONTINUES.
IPMF
O/FLOW
B
HT
TEE RISER.
FLOW DIRECTION ARROW.
PIPEWORK ACOUSTICALLY TREATED.
AMENDMENT SYMBOL.A
20
exCW
40
CW
40
CW
H-001
GD
HWU
RUN OF HOSE.ROH
TMV/VCG
GREASE WASTE DRAINAGEGW
GREASE WASTE VENTGWV
7
A
8
B
6
5
C D E F G H I
7
J
8
6
5
4
3
2
1
A B C D E F G H I
4
3
2
1
J
All dimensions to be verified on site/s prior to commencment of
on-site work and/ or off-site prefabrication. Figured dimension to
be taken in preference to scaled dimensions. This drawing is
copyright and remains the property of JHA Consulting Engineers.
Reproduction in whole or part of these drawings without written
consent constitutes an infringment of copyright.
JOB No. DRAWING No. REV
DRAWN CHECKED APPROVED
TITLE
Rev Date VerifiedDescription
Description FromDrawing NumberRev
REFERENCE DRAWINGS
REVISIONS / AMENDMENTS
SCALE @ A1
PROJECT
ARCHITECT
CHILD CARE CENTRE
823-825 BOTANY ROAD
ROSEBERY, NSW 2018
LOT 1 DP838607
189 Kent Street
Sydney, NSW 2000
www.sbarchitects.com.au
CONSULTANT
Level 3, 146 Arthur Street,
North Sydney
NSW 2060
Australia
+61 (02) 9437 1000
www.jhaservices.com
HYDRAULIC SERVICES
COVER SHEET, LEGEND OF
SYMBOLS, GENERAL NOTES &
DRAWING LIST
N.S. B.S. P.C. 1:100
150049 H000 A
A 12.11.15 B.S.TENDER ISSUE
TENDER ISSUENOT TO BE USED FOR CONSTRUCTION
100Ø
150Ø
OFG
100Ø
100
exVPEX 100Ø VP TO BE RETAINED.
INTERCONNECT NEW VENT DRAIN
AT BASE OF VENT SHAFT
GW110Ø
100Ø
BTS x 2RV
BOX IN PIPES
100Ø
100Ø
SHR/VFW
GW
GW
GW
GW
100Ø
100Ø 100Ø
100Ø
110Ø
HD
PE
110Ø HDPE
100Ø
100
AD
100
AD
110
GWAD
CO
CO
DWC
VFW
DB
BB
VB
CR SK
CR SK
CR SK
CO
WC
VFW
100Ø
OFG
100
AD
50Ø WP
IN WALL
50Ø WPIN WALL
50Ø WP
IN WALL
50Ø WP
IN WALL
100Ø
100Ø DTU FORUNDER RPZD
TWO 600x450 DI
COVERS AND FRAME
1500 LITRE CAPACITY
CONCRETE GREASE
ARRESTOR
600x450 DI COVERS
AND FRAME
100Ø
BOX IN
BOX IN
100Ø
40Ø
100Ø
100Ø
BOX IN
100Ø
BREAK OUT EX SEWER BOUNDARY
TRAP AND INSTALL NEW 150Ø
BOUNDARY TRAP INTO EX SEWER
MAIN JUNCTION. PROVIDE 150Ø
STAINLESS STEEL BTS AT SURFACE.
150Ø
CIP
SE
WE
R M
AIN
150Ø
150Ø CIP SEWER MAIN 150Ø CIP SEWER MAIN
EX SMH
CLEAN OUT, BREAK UP
AND REMOVE TO TIP
EX CONCRETE
GREASE ARRESTOR.
NOTE:
SAW CUT CONCRETE SLAB. REMOVE CONCRETE
& EXCAVATE MATERIAL TO TIP. PAY TIP COSTS.
REINSTATE CONCRETE FLOOR
LEVELS ARE INDICATIVE ONLY ON HOW FAR
BELOW EXISTING GROUND/SURFACE THE
DRAINAGE TO BE INSTALLED. CONTRACTOR
SHALL CONFIRM ON-SITE LEVEL'S & LOCATION
OF EXISTING SERVICES
BOX IN
100
DP
100
DP
100
DP
100
DP
6 L/S
6 L/S
6 L/S
6 L/S
40Ø WP
IN WALL 100Ø
100Ø10
0Ø
PR0VIDE 100Ø INSPECTION
FITTING 500 ABOVE FLOOR
PR0VIDE 100Ø INSPECTION
FITTING 500 ABOVE FLOOR
150
DP PAINTED SEWER
GRADE UPVC PIPE
ee
ee
ee
ee
ee
e
e e e e
e NEW 150Ø
INSPECTION FITTING
PR0VIDE 100Ø
INSPECTION
FITTING 500
ABOVE FLOOR
PR0VIDE 110Ø
INSPECTION
FITTING 500
ABOVE FLOOR
40Ø
100Ø
110Ø HDPE
150x100
exDPTO REMAIN
FINISHED LEVEL TO
BE 225mm BELOW
FLOOR LEVEL
PROVIDE HT OVER100
VP
40Ø WPIN WALL
PR0VIDE 100Ø
INSPECTION
FITTING 500
ABOVE FLOOR
SAW CUT EX
CONC. FLOOR
AND REPLACE
50
AC/CD IN WALL
50Ø
50Ø
50
AC/CD IN WALL
100Ø STW
CUT IN NEW 150 x 100
JUNCTION
100Ø DTU FOR
AC/CD.
SAW CUT
CONCRETE AND
REPLACE
7
A
8
B
6
5
C D E F G H I
7
J
8
6
5
4
3
2
1
A B C D E F G H I
4
3
2
1
J
All dimensions to be verified on site/s prior to commencment of
on-site work and/ or off-site prefabrication. Figured dimension to
be taken in preference to scaled dimensions. This drawing is
copyright and remains the property of JHA Consulting Engineers.
Reproduction in whole or part of these drawings without written
consent constitutes an infringment of copyright.
JOB No. DRAWING No. REV
DRAWN CHECKED APPROVED
TITLE
Rev Date VerifiedDescription
Description FromDrawing NumberRev
REFERENCE DRAWINGS
REVISIONS / AMENDMENTS
SCALE @ A1
PROJECT
ARCHITECT
CHILD CARE CENTRE
823-825 BOTANY ROAD
ROSEBERY, NSW 2018
LOT 1 DP838607
189 Kent Street
Sydney, NSW 2000
www.sbarchitects.com.au
CONSULTANT
Level 3, 146 Arthur Street,
North Sydney
NSW 2060
Australia
+61 (02) 9437 1000
www.jhaservices.com
HYDRAULIC SERVICES
GROUND FLOOR
SANITARY PLUMBING AND
DRAINAGE
N.S. B.S. P.C. 1:100
150049 H100 A
P1 24.09.15 B.S.FOR INFORMATION
1 : 100-A1 1 : 200-A3
2 1 0 2 4 6 8 m
TENDER ISSUENOT TO BE USED FOR CONSTRUCTION
NOTES:
1. MINIMUM DRAINAGE PIPE GRADE TO BE 1:60.
A 12.11.15 B.S.TENDER ISSUE
JWC JWC JWC
JWC
VFW
B
DSHR/VFW
CR SK CR SK
B
CR SK
JWC
CR SK
DB
VFWVFW
DWCSK
100
AD
100
VP
100
AD
50
VP
50
VP
100
AD
100Ø
100Ø
100Ø
SOUND INSULATE ALL
SANITARY PLUMBING PIPESSOUND INSULATE ALL
SANITARY PLUMBING PIPES
SOUND INSULATE ALL
SANITARY PLUMBING PIPES
110
GWAD
DTU/HWU
FW
50Ø WP
IN WALL
50Ø WP
IN WALL
40Ø WP
IN WALL
40Ø WP
IN WALL
50Ø WP
IN WALL
50Ø WP
IN WALL
50Ø WPIN WALL
40Ø WP IN WALL
50Ø WP IN WALL
40Ø WP IN WALL
40Ø WPIN WALL
LT
IN WALL
50Ø WP IN WALL
DRINKING TROUGH
100Ø
40Ø
100Ø
100
exVP
40Ø
CS
100Ø
PROVIDE GRATE
SEAL IN FW RISER
100Ø
100Ø
110Ø HDPE
110Ø HDPE
100Ø
DRINKING
FOUNTAIN
DRINKING
FOUNTAIN
DRINKING
FOUNTAIN
IN WALL
100Ø
100Ø
100Ø
100Ø
WASH
THROUGH
100
DP
100
DP
100
DP
100
DP
6 L/S
6 L/S
6 L/S
6 L/S
SPS SUPERFLOW
S/S RWO
SPS SUPERFLOW
S/S RWO
SPS SUPERFLOW
S/S RWO
SPS SUPERFLOW
S/S RWO
SK
B
DW
SK
TD/BCW
INSTALL 110Ø IN SINK DRY
BASKET ARRESTOR100
GWVP
VBTFW
110Ø
HDPE
50Ø HDPE
WP IN WALL
50Ø HDPE
WP IN WALL
GW
GW
150
DP PAINTED SEWER
GRADE UPVC PIPE
110Ø
110Ø HDPE
GWVP
GWVP
40Ø HDPE
WP IN WALL
40Ø110Ø
100Ø
100Ø
100
VPREUSE
150x100
exDPTO REMAIN
100Ø
100Ø
100Ø
50Ø
50Ø
110Ø
HD
PE
50Ø50
AC/CD IN WALL50
AC/CD IN WALL
50Ø
7
A
8
B
6
5
C D E F G H I
7
J
8
6
5
4
3
2
1
A B C D E F G H I
4
3
2
1
J
All dimensions to be verified on site/s prior to commencment of
on-site work and/ or off-site prefabrication. Figured dimension to
be taken in preference to scaled dimensions. This drawing is
copyright and remains the property of JHA Consulting Engineers.
Reproduction in whole or part of these drawings without written
consent constitutes an infringment of copyright.
JOB No. DRAWING No. REV
DRAWN CHECKED APPROVED
TITLE
Rev Date VerifiedDescription
Description FromDrawing NumberRev
REFERENCE DRAWINGS
REVISIONS / AMENDMENTS
SCALE @ A1
PROJECT
ARCHITECT
CHILD CARE CENTRE
823-825 BOTANY ROAD
ROSEBERY, NSW 2018
LOT 1 DP838607
189 Kent Street
Sydney, NSW 2000
www.sbarchitects.com.au
CONSULTANT
Level 3, 146 Arthur Street,
North Sydney
NSW 2060
Australia
+61 (02) 9437 1000
www.jhaservices.com
HYDRAULIC SERVICES
FIRST FLOOR
SANITARY PLUMBING AND
DRAINAGE
N.S. B.S. P.C. 1:100
150049 H101 A
P1 24.09.15 B.S.FOR INFORMATION
1 : 100-A1 1 : 200-A3
2 1 0 2 4 6 8 m
TENDER ISSUENOT TO BE USED FOR CONSTRUCTION
NOTES:
1. REMOVE EX PIPES AND FIRE RATE PENETRATIONS
THROUGH FLOOR SLAB.
2. CORE DRILL NEW PIPE PENETRATIONS THROUGH
EX CONC. FLOOR SLAB.
3. INSTALL RETROFIT TYPE FIRE STOP COLLARS TO
ALL PIPES.
A 12.11.15 B.S.TENDER ISSUE
NOTES:
1. REMOVE EX PIPES AND FIRE RATE PENETRATIONS
THROUGH FLOOR SLAB.
2. CORE DRILL NEW PIPE PENETRATIONS THROUGH
EX CONC. FLOOR SLAB.
3. INSTALL RETROFIT TYPE FIRE STOP COLLARS TO
ALL PIPES.
100
VP
50
VP
100
GWVP
100
GWVP
50
VP
200
FLUE
EX 150 x 100 OVERFLOW FROM
BOX GUTTER TO REMAIN
PROVIDE NEW BOX GUTTER OVERFLOW 400
LONG x 100 HIGH WITH BOTTOM OF OVERFLOW
50mm ABOVE BASE OF BOX GUTTER.
PROVIDE NEW BOX GUTTER OVERFLOW 400
LONG x 100 HIGH WITH BOTTOM OF OVERFLOW
50mm ABOVE BASE OF BOX GUTTER.
RETAIN EX 150 x 100 mm SHEETMETAL DP
EX 150Ø PIPE OVERFLOW FROM BOX
GUTTER TO REMAIN
150
DPREMOVE EX 150 x 100
SHEETMETAL DP
PAINTED SEWER
GRADE UPVC PIPE
RETAIN EX RWT AND REPLACE OUTLET
SPIGOT WITH NEW 150Ø SPIGOT.
100Ø OFFSET UNDER
STEEL BEAM
100Ø OFFSET
UNDER ROOF
100
VP
40° OFFSET IN STAINLESS
STEEL FLUE PIPE AT HL
UNDER BOX GUTTER
150
exDP
EX 150 x 100 OVERFLOW FROM
BOX GUTTER TO REMAIN
PROVIDE NEW BOX GUTTER
OVERFLOW 400 LONG x 100 HIGH
WITH BOTTOM OF OVERFLOW 50mm
ABOVE BASE OF BOX GUTTER.
EX 150Ø PIPE OVERFLOW FROM
BOX GUTTER TO REMAIN
PROVIDE NEW BOX GUTTER
OVERFLOW 400 LONG x 100 HIGH
WITH BOTTOM OF OVERFLOW 50mm
ABOVE BASE OF BOX GUTTER.
7
A
8
B
6
5
C D E F G H I
7
J
8
6
5
4
3
2
1
A B C D E F G H I
4
3
2
1
J
All dimensions to be verified on site/s prior to commencment of
on-site work and/ or off-site prefabrication. Figured dimension to
be taken in preference to scaled dimensions. This drawing is
copyright and remains the property of JHA Consulting Engineers.
Reproduction in whole or part of these drawings without written
consent constitutes an infringment of copyright.
JOB No. DRAWING No. REV
DRAWN CHECKED APPROVED
TITLE
Rev Date VerifiedDescription
Description FromDrawing NumberRev
REFERENCE DRAWINGS
REVISIONS / AMENDMENTS
SCALE @ A1
PROJECT
ARCHITECT
CHILD CARE CENTRE
823-825 BOTANY ROAD
ROSEBERY, NSW 2018
LOT 1 DP838607
189 Kent Street
Sydney, NSW 2000
www.sbarchitects.com.au
CONSULTANT
Level 3, 146 Arthur Street,
North Sydney
NSW 2060
Australia
+61 (02) 9437 1000
www.jhaservices.com
HYDRAULIC SERVICES
ROOF PLAN
N.S. B.S. P.C. 1:100
150049 H102 A
P1 24.09.15 B.S.FOR INFORMATION
1 : 100-A1 1 : 200-A3
2 1 0 2 4 6 8 m
TENDER ISSUENOT TO BE USED FOR CONSTRUCTION
NOTES:
1. REMOVE EX PIPES AND FIRE RATE PENETRATIONS
THROUGH FLOOR SLAB.
2. CORE DRILL NEW PIPE PENETRATIONS THROUGH
EX CONC. FLOOR SLAB.
3. INSTALL RETROFIT TYPE FIRE STOP COLLARS TO
ALL PIPES.
4. HYDRAULIC TRADE TO HIGH PRESSURE WASH OUT
ALL EXISTING RAINWATER DOWNPIPES AND IN
GROUND STORMWATER DRAINAGE TO ENSURE
THAT THERE ARE NO BLOCKAGES IN THE PIPE.
A 12.11.15 B.S.TENDER ISSUE
FHR
DWC
DB
HT
DSHR
FHR
CR
SK
VB
BB
CR SK
CR SK
WC
40Ø
32Ø
40Ø 25Ø
50Ø50Ø
50Ø
50Ø
EX GAS
25Ø
20
GAS
25
FHR
25
FHR
25Ø25Ø
50
CW
40
GAS
25
HWR
40
HW
25
FHR
25
FHR
40Ø
32Ø
EX
25Ø
CW
P
20
CWRISE ON
COLUMN FACE
50Ø CALEFFI SPRING ADJUSTABLE
PRESSURE REDUCING VALVE WITH
OUTLET PRESSURE SET AT 500kPa
NEW 50Ø RPZD ASSEMBLY
NEW 40Ø WATER METER
NEW 50Ø BALL VALVE
PROVIDE NEW 50Ø Cu CW RISER
NEW HT20 BV
HT
20Ø RPZD 500mm ABOVE
GROUND WITHIN 5m OF
GREASE ARRESTOR
@H/L
20Ø
SIGN ON WALL ''DO
NOT DRINK''
ENWARE 4 POINT TMV BOX
ON WALL AT BACK OF
CUPBOARD WITH BASE
300mm ABOVE FLOOR
ENWARE 4 POINT TMV/VCG
BOX IN WALL WITH BASE
300mm ABOVE FLOOR
ENWARE 4 POINT TMV/VCG BOX
ON WALL OF CUPBOARD WITH
BASE 300mm ABOVE FLOOR
50Ø Cu BREECHING PIECE
NEW 25Ø MAIN TAP
EX 25Ø MAIN TAPING
200Ø CICL WATERMAIN
50Ø
CW
40Ø
20Ø
20Ø CW & 20Ø HW
RISE TO ABOVE
40Ø
40Ø
20Ø CW & 20Ø HW
RISE TO ABOVE
HT OVER
SEWER GULLY
40Ø
40Ø
HT
HT OVER SEWER
GULLY WITH
BACKFLOW
PREVENTER
40Ø40Ø40Ø
25Ø
20Ø CW & 20Ø HW
RISE TO ABOVE
20Ø CW & 20Ø HW
RISE TO ABOVE
20Ø CW & 20Ø HW
DROP IN WALL
40Ø25Ø
H/L
40Ø
40Ø
50Ø
WW
20Ø
20Ø
25Ø
20Ø
20Ø
20Ø CW & 20Ø HW
DROP IN WALL
15Ø
15Ø
20Ø
20Ø
20Ø 20
Ø
40Ø
40Ø
40Ø
20Ø20Ø CW & 20Ø HW
DROP IN WALL
20Ø CW & 20Ø HW
RISE TO ABOVE
40Ø
25Ø
20Ø CW @H/L
IN GRD
LOCATE EX COPPER
GAS PIPE AND
RECONNECT NEW PIPE
RELOCATE EX NG METER AND
REGULATOR FROM INSIDE OF
BUILDING TO OUTSIDE. PROVIDE
ALL VALVES AND FITTINGS.
H
EX 20Ø CW SERVICE
EX 25Ø WATER METER
RETURN TO SYDNEY WATER
EX INCOMING 25Ø CW
WATER SERVICE
X
X
X
X
X
X
X
X
X
X
X
XX
XX
EX 25Ø CW SERVICE
100Ø
100Ø
CIC
L W
ATE
RM
AIN
ENWARE 4 POINT TMV/VCG BOX
IN WALL WITH BASE 300mm
ABOVE FLOOR 20Ø
40
HW
40
HW20Ø CW & 20Ø HW
RISE TO ABOVE
20Ø CW RISE TO ABOVE
20Ø CW & 20Ø HW
DROP IN WALL
@H/L
@H/L
@H/L
50Ø
40Ø
HTBV
20Ø
7
A
8
B
6
5
C D E F G H I
7
J
8
6
5
4
3
2
1
A B C D E F G H I
4
3
2
1
J
All dimensions to be verified on site/s prior to commencment of
on-site work and/ or off-site prefabrication. Figured dimension to
be taken in preference to scaled dimensions. This drawing is
copyright and remains the property of JHA Consulting Engineers.
Reproduction in whole or part of these drawings without written
consent constitutes an infringment of copyright.
JOB No. DRAWING No. REV
DRAWN CHECKED APPROVED
TITLE
Rev Date VerifiedDescription
Description FromDrawing NumberRev
REFERENCE DRAWINGS
REVISIONS / AMENDMENTS
SCALE @ A1
PROJECT
ARCHITECT
CHILD CARE CENTRE
823-825 BOTANY ROAD
ROSEBERY, NSW 2018
LOT 1 DP838607
189 Kent Street
Sydney, NSW 2000
www.sbarchitects.com.au
CONSULTANT
Level 3, 146 Arthur Street,
North Sydney
NSW 2060
Australia
+61 (02) 9437 1000
www.jhaservices.com
HYDRAULIC SERVICES
GROUND FLOOR
SPACIALS FOR WATER &
GAS SERVICES
N.S. B.S. P.C. 1:100
150049 H200 A1 : 100-A1 1 : 200-A3
2 1 0 2 4 6 8 m
TENDER ISSUENOT TO BE USED FOR CONSTRUCTION
A 12.11.15 B.S.TENDER ISSUE
FHR
25Ø CW RISE
FROM BELOW
FHR
CR SK
DWC
DB
SK
LT
HT
HT
RISE FROM BELOW20
CW
HT
150mm HIGH CONCRETE
HOB TO CONTAIN
WATER
40
HW
40
CW
HT
CIRCULATING PUMP
SET. REFER DETAIL
RHEEM GAS HOT WATER HEATER MODEL
621275 WITH 200Ø FLUE PIPE. ALLOW 200Ø
FLUE PIPE THROUGH ROOF. PROVIDE 20Ø
DRAIN TO TERMINATE OVER DTU
WM
DSHR
40
GAS
JWC
JWC
CR SK
BDRINKING
FOUNTAIN
CR SKCR SK
25
FHR
25
FHR
ENWARE 5 POINT
TMV/VCG BOX IN WALL
WITH BASE 1500mm
ABOVE FLOOR OVER CS
ENWARE 4 POINT
TMV/VCG BOX IN WALL
WITH BASE 300mm
ABOVE FLOOR (TYPICAL)
20Ø CW
DRINKING
FOUNTAIN20Ø @H/L
20Ø CW DROP
IN WALL
20Ø
20Ø
@H
/L
20Ø WW IN
WALL
DRINKING
THROUGH
20Ø CW & 20Ø HW RISE
IN WALL FROM BELOW
15Ø20Ø CW & 20Ø HW RISE
IN WALL FROM BELOW
15Ø
15Ø
20Ø
20Ø
WW
20Ø
DW
BCW
20Ø CW & 20Ø HW RISE
IN WALL FROM BELOW
CS
20Ø CW & 20Ø HW RISE
IN WALL FROM BELOW
15Ø 20Ø 20Ø
HT
20Ø
20Ø
15Ø
15Ø20Ø15Ø
WASH THROUGH
20Ø @H/L20Ø CW & 20Ø HW
DROP IN WALL
DRINKING
FOUNTAIN
ENWARE 4 POINT
TMV/VCG BOX IN WALL
WITH BASE 300mm
ABOVE FLOOR (TYPICAL)
JWC JWC JWC
15Ø
ENWARE 4 POINT
TMV/VCG BOX IN WALL
WITH BASE 300mm
ABOVE FLOOR (TYPICAL)
20Ø CW & 20Ø HW RISE
IN WALL FROM BELOW
ENWARE 4 POINT
TMV/VCG BOX IN WALL
WITH BASE 300mm
ABOVE FLOOR (TYPICAL)
B
HT
SK
DWSKBWU
40
HW
40
HW
20Ø CW & 20Ø HW RISE
IN WALL FROM BELOW
20Ø GAS RISE IN WALL
FROM BELOW
20Ø CW RISE IN
WALL FROM BELOW
15Ø
ENWARE IN WALL 3
POINT TMV/VCG BOX
WITH BASE 150mm AFFL
20Ø
GAS
COOKER
20Ø NG BV
15Ø
15Ø
15Ø 20Ø20Ø
PROVIDE ASTS
UNDER SINK
BVx2
20Ø CW & 20Ø HW
DROP IN WALL
WALL TYPE BOILING WATERUNIT .REFER DETAIL.
7
A
8
B
6
5
C D E F G H I
7
J
8
6
5
4
3
2
1
A B C D E F G H I
4
3
2
1
J
All dimensions to be verified on site/s prior to commencment of
on-site work and/ or off-site prefabrication. Figured dimension to
be taken in preference to scaled dimensions. This drawing is
copyright and remains the property of JHA Consulting Engineers.
Reproduction in whole or part of these drawings without written
consent constitutes an infringment of copyright.
JOB No. DRAWING No. REV
DRAWN CHECKED APPROVED
TITLE
Rev Date VerifiedDescription
Description FromDrawing NumberRev
REFERENCE DRAWINGS
REVISIONS / AMENDMENTS
SCALE @ A1
PROJECT
ARCHITECT
CHILD CARE CENTRE
823-825 BOTANY ROAD
ROSEBERY, NSW 2018
LOT 1 DP838607
189 Kent Street
Sydney, NSW 2000
www.sbarchitects.com.au
CONSULTANT
Level 3, 146 Arthur Street,
North Sydney
NSW 2060
Australia
+61 (02) 9437 1000
www.jhaservices.com
HYDRAULIC SERVICES
FIRST FLOOR
SPACIALS FOR WATER &
GAS SERVICES
N.S. B.S. P.C. 1:100
150049 H201 A1 : 100-A1 1 : 200-A3
2 1 0 2 4 6 8 m
TENDER ISSUENOT TO BE USED FOR CONSTRUCTION
NOTES:
1. REMOVE EX PIPES AND FIRE RATE PENETRATIONS
THROUGH FLOOR SLAB.
2. CORE DRILL NEW PIPE PENETRATIONS THROUGH
EX CONC. FLOOR SLAB.
3. INSTALL RETROFIT TYPE FIRE STOP COLLARS TO
ALL PIPES.
A 12.11.15 B.S.TENDER ISSUE
100
exVP
150x100
exDP
150x100
exDP
EX FHR
REMOVE EXISTING FHR
AND WATER PIPES25Ø Cu CW RISE FROM
UNDER FLOOR
REMOVE ALL SANITARY
FIXTURES, HW HEATER,
TRAPS AND PIPES
EX HT
X
X
X
X
X
X
EXISTING 20Ø CW
PIPE AT HIGH LEVEL
TO BE REUSED TO BE RETAINED
TO BE REMOVED
7
A
8
B
6
5
C D E F G H I
7
J
8
6
5
4
3
2
1
A B C D E F G H I
4
3
2
1
J
All dimensions to be verified on site/s prior to commencment of
on-site work and/ or off-site prefabrication. Figured dimension to
be taken in preference to scaled dimensions. This drawing is
copyright and remains the property of JHA Consulting Engineers.
Reproduction in whole or part of these drawings without written
consent constitutes an infringment of copyright.
JOB No. DRAWING No. REV
DRAWN CHECKED APPROVED
TITLE
Rev Date VerifiedDescription
Description FromDrawing NumberRev
REFERENCE DRAWINGS
REVISIONS / AMENDMENTS
SCALE @ A1
PROJECT
ARCHITECT
CHILD CARE CENTRE
823-825 BOTANY ROAD
ROSEBERY, NSW 2018
LOT 1 DP838607
189 Kent Street
Sydney, NSW 2000
www.sbarchitects.com.au
CONSULTANT
Level 3, 146 Arthur Street,
North Sydney
NSW 2060
Australia
+61 (02) 9437 1000
www.jhaservices.com
HYDRAULIC SERVICES
GROUND FLOOR
DEMOLITION PLAN
N.S. B.S. P.C. 1:100
150049 H300 A1 : 100-A1 1 : 200-A3
2 1 0 2 4 6 8 m
TENDER ISSUENOT TO BE USED FOR CONSTRUCTION
A 12.11.15 B.S.TENDER ISSUE
REMOVE ALL SANITARY FIXTURES,
HW HEATER, TRAPS AND PIPES
150x100
exDPTO BE REMOVED
7
A
8
B
6
5
C D E F G H I
7
J
8
6
5
4
3
2
1
A B C D E F G H I
4
3
2
1
J
All dimensions to be verified on site/s prior to commencment of
on-site work and/ or off-site prefabrication. Figured dimension to
be taken in preference to scaled dimensions. This drawing is
copyright and remains the property of JHA Consulting Engineers.
Reproduction in whole or part of these drawings without written
consent constitutes an infringment of copyright.
JOB No. DRAWING No. REV
DRAWN CHECKED APPROVED
TITLE
Rev Date VerifiedDescription
Description FromDrawing NumberRev
REFERENCE DRAWINGS
REVISIONS / AMENDMENTS
SCALE @ A1
PROJECT
ARCHITECT
CHILD CARE CENTRE
823-825 BOTANY ROAD
ROSEBERY, NSW 2018
LOT 1 DP838607
189 Kent Street
Sydney, NSW 2000
www.sbarchitects.com.au
CONSULTANT
Level 3, 146 Arthur Street,
North Sydney
NSW 2060
Australia
+61 (02) 9437 1000
www.jhaservices.com
HYDRAULIC SERVICES
FIRST FLOOR
DEMOLITION PLAN
N.S. B.S. P.C. 1:100
150049 H301 A1 : 100-A1 1 : 200-A3
2 1 0 2 4 6 8 m
TENDER ISSUENOT TO BE USED FOR CONSTRUCTION
A 12.11.15 B.S.TENDER ISSUE
162
16
2
36
Ø101.6
SPECIFICATIONSStainless Steel Floor Waste unitshall be Model FW3from Stainless Metal Craft. Phone 02 47355666www.smcstainless.com.au
CEILING LINE
100 x 50 UPVC TAPER REDUCER
FOR CONDENSATE DRAINAGESCALE 1:20
50Ø UPVC CONDENSATE
DRAINAGE PIPE
150 x 50 UPVC TAPER
REDUCER
TYPICAL DETAIL OF STAINLESS STEEL METAL CRAFT
CLEAR OUT. CODE: CO4
BENCH TOP
SINK BOWL
50mm TRAP
DISHWASHER
CONNECTION FOR
50mm PLUG
& WASHER50UPVC
50
50
TYPICAL AC TUNDISH - SINK TRAP CONNECTION
50 UPVC PIPE
CONCEALED IN WALL
50mm JUNCTION WITH 50mm CAP
AND LINING AND MI ADAPTOR
DRAINAGE
SUSPENDED CEILING
100x50 UPVC TAPER REDUCER
SCALE 1:10
50 UPVC CONDENSATION
DRAINAGE CONCEALED INWALL
SUSPENDED CEILING
SHOWER FLOOR WASTE
100Ø CP
FLOOR GRATE
100 SHOWER FLOOR WASTE
GULLY
CORRIDORSHOWER
A/C CONDENSATION DRAINAGE AT SHOWER FLOOR WASTE
NOT TO SCALE
PROBE STEM
COPPER CAP
DIAL TYPE THERMOMETER
ELEVATION
INSTALLATION DETAIL
LINE SIZE 'A'
REFER SCHEDULE
NOT TO SCALE
100mm DIAL TYPE
SPECIFIED INSTALLED
IN VERTICAL POSITION
THERMOMETER AS
(ALTERNATE
LINE SIZE 'A'
REFER SCHEDULE
REFER SCHEDULE
MOUNTING TUBE 'B'
15mm BSP BRASS BOSS
(ALTERNATE
FLOW) FLOW
FLOW FLOW)
8080
BE ACHIEVED IN A HORIZONTAL
3. ALTERNATIVELY THIS INSTALLATION CAN
POSITION USING DOBBIE MODEL V540
THERMOMETER.
100 100
INCORPORATE THE ABOVE ARRANGEMENT
AND ADDITIONAL BENDS ARE REQUIRED
AS NECESSARY.
1. PUMP DIAGRAM DRAWINGS ARE TO
INSTALLED WHERE IT WOULD CREATE
AN AIR TRAP. (SEE BELOW)
2. DIAL THERMOMETER IS TO BE
65
50
32
40
65
80
50
50
DIAL TYPE THERMOMETER
TUBE SIZING SCHEDULE
DIAMETERmm
25
A
DIAMETERmm
40
B
NOTE:
NOT
"OD"
"Spigot"
90
SPECIFICATIONSStainless Steel Floor Waste unitshall be Model FW3from Stainless Metal Craft. Phone 02 47355666www.smcstainless.com.au
Model Spigot OD
CO4 96 130
CO6 152.4 170
220Ø STAINLESS STEEL SKIRT
AC SHEETING
5Ø WEEP HOLES @ 20mm INTERNALS
BATHROOM FLOOR WASTE - TILE INSERT WITH PUDDLE FLANGENOT TO SCALE
ELEVATION
PLAN
STONE OR TILE INSERT
PLAN
ELEVATION
ELEVATION
SECTIONAL ELEVATION
SECTIONAL ELEVATION
REBATE FLOOR SHEET TO
ACCOMMODATE FW SKIRT
HYDRAULIC SERVICES
DETAIL SHEET 1
N.S. B.S. P.C. N.T.S.
150049 H400 A
TENDER ISSUENOT TO BE USED FOR CONSTRUCTION
7
A
8
B
6
5
C D E F G H I
7
J
8
6
5
4
3
2
1
A B C D E F G H I
4
3
2
1
J
All dimensions to be verified on site/s prior to commencment of
on-site work and/ or off-site prefabrication. Figured dimension to
be taken in preference to scaled dimensions. This drawing is
copyright and remains the property of JHA Consulting Engineers.
Reproduction in whole or part of these drawings without written
consent constitutes an infringment of copyright.
JOB No. DRAWING No. REV
DRAWN CHECKED APPROVED
TITLE
Rev Date VerifiedDescription
Description FromDrawing NumberRev
REFERENCE DRAWINGS
REVISIONS / AMENDMENTS
SCALE @ A1
PROJECT
ARCHITECT
CHILD CARE CENTRE
823-825 BOTANY ROAD
ROSEBERY, NSW 2018
LOT 1 DP838607
189 Kent Street
Sydney, NSW 2000
www.sbarchitects.com.au
CONSULTANT
Level 3, 146 Arthur Street,
North Sydney
NSW 2060
Australia
+61 (02) 9437 1000
www.jhaservices.com
A 12.11.15 B.S.TENDER ISSUE
95
77.5
230
6023
0
350
350
150
(RE
F)
COLD IN
WARM OUTHOT IN
38
6023
0
75
6 T
YP
20 TYP
30 TYP370
370
HOT IN WARM OUT COLD IN
PUMP DUTY
FLUID PUMPED
UNIT WEIGHT
SUCTION
DISCHARGE
PUMP MODEL
DRIVER
TRANSMISSION
PAINT SPEC.
.
GRUNDFOS UPS20-60N (SPEED #2)
ELECTRIC 240V
CLOSE COUPLED
GALVANISED
0.3L/s @ 2.5m HEAD
80kg APPROX.
HOT WATER
32mm COPPER PIPE
32mm COPPER PIPE .
ENWARE THREE POINT THERMOSTATIC MIXING
VALVE/CONTROL VALVE GROUP BOXNOT TO SCALE
PUMPS ELECTRICAL
CONTROL PANEL
100Ø DIAL FACE PRESSURE
GAUGE
25Ø
50Ø
25Ø
100DIA. DIAL FACE
TEMPERATURE GAUGE
DUAL HOT WATER
CIRCULATOR PUMPS
FLOW
25Ø
STAD BALANCING
VALVES x 2
STAINLESS STEEL FLEXIBLE
CONNECTORS x4
HOT DIP GALVANISED
STEEL SUPPORT STAND
DETAIL OF GRUNDFOS UPS20-60N ELECTRIC PUMP SETNOT TO SCALE
SIDE ELEVATION FRONT ELEVATION
PLAN
WHITE POWDER
COATED LOCKABLE
HINGED ACCESS DOOR
VALVE CONTROL GROUP BOX IN WALL.
COORDINATE WITH ARCHITECTS
ISOLATION VALVE & NON RETURN VALVE
TEST POINT & STRAINER ACCESS
PIPE MOUNTING BRACKET
PEACH PLUG BRAZED IN MIXED WATER
PIPE FOR TESTING
ENWARE 1508 THERMOSTATIC MIXING
VALVE LOCK SHIELD
THERMOSTATIC MIXING VALVE
THERMOSTATIC MIXING VALVE MOUNTING
BRACKET
20Ø UNION (TYPICAL)
NOTE:
NOT & COLD WATER FEED PIPEWORK TO
TMV IS NOT TO HAVE ANY BRANCHES
WITHIN 1m OF TMV
FRONT ELEVATION (OPEN) FRONT ELEVATION (CLOSED)SIDE ELEVATION
100Ø DIAL FACE
TEMPERATURE GAUGE
25Ø
GALV STEEL ANGLE
FRAME
BRONZE SPRING CHECKVALVE x 2
95
75
152.5
77.5
230
6023
0
350
350
150
(RE
F)
COLD IN
COLD OUTWARM OUTHOT IN
38
6023
0
75
6 T
YP
20 TYP
30 TYP370
370
HOT IN WARM OUT
COLD OUT
COLD IN
ENWARE FOUR POINT THERMOSTATIC MIXING
VALVE/CONTROL VALVE GROUP BOXNOT TO SCALE
WHITE POWDER
COATED LOCKABLE
HINGED ACCESS DOOR
VALVE CONTROL GROUP BOX IN WALL.
COORDINATE WITH ARCHITECTS
ISOLATION VALVE & NON RETURN VALVE
20Ø BALL VALVE WITH BUTTERFLY HANDLE
TEST POINT & STRAINER ACCESS
20Ø UNION (TYPICAL)
PIPE MOUNTING BRACKET
PEACH PLUG BRAZED IN MIXED WATER
PIPE FOR TESTING
ENWARE 1508 THERMOSTATIC MIXING
VALVE LOCK SHIELD
THERMOSTATIC MIXING VALVE
THERMOSTATIC MIXING VALVE MOUNTING
BRACKET
20Ø UNION (TYPICAL)
NOTE:
NOT & COLD WATER FEED PIPEWORK TO
TMV IS NOT TO HAVE ANY BRANCHES
WITHIN 1m OF TMV
FRONT ELEVATION (OPEN) FRONT ELEVATION (CLOSED)SIDE ELEVATION
95
75
152.5
77.5
230
6023
0
350
350
150
(RE
F)
COLD IN
COLD OUTWARM OUTHOT IN
38
6023
0
75
6 T
YP
20 TYP
30 TYP370
370
HOT IN WARM OUT
COLD OUT
COLD IN
HOT OUT
ENWARE FIVE POINT THERMOSTATIC MIXING
VALVE/CONTROL VALVE GROUP BOXNOT TO SCALE
WHITE POWDER
COATED LOCKABLE
HINGED ACCESS DOOR
VALVE CONTROL GROUP BOX IN WALL.
COORDINATE WITH ARCHITECTS
ISOLATION VALVE & NON RETURN VALVE
20Ø BALL VALVE WITH BUTTERFLY HANDLE
TEST POINT & STRAINER ACCESS
20Ø UNION (TYPICAL)
PIPE MOUNTING BRACKET
PEACH PLUG BRAZED IN MIXED WATER
PIPE FOR TESTING
ENWARE 1508 THERMOSTATIC MIXING
VALVE LOCK SHIELD
THERMOSTATIC MIXING VALVE
THERMOSTATIC MIXING VALVE MOUNTING
BRACKET
20Ø UNION (TYPICAL)
NOTE:
NOT & COLD WATER FEED PIPEWORK TO
TMV IS NOT TO HAVE ANY BRANCHES
WITHIN 1m OF TMV
FRONT ELEVATION (OPEN) FRONT ELEVATION (CLOSED)SIDE ELEVATION
HOT OUT
ISOMETRIC DIAGRAM OF PIPEWORK
CONNECTIONS TO RHEEM MODEL
621275 NG HOT WATER HEATERSCALE: NOT TO SCALE
TEMPERATURE PRESSURE RELIEF
VALVE
TEMPERATURE PRESSURE RELIEF
VALVE DRAIN LINE
40Ø COLD WATER
CONNECTION
20Ø
FIRST FLOOR
25Ø HWR
PUMPS ELECTRICAL
CONTROL PANEL.
REFER TO DETAIL
BAYTAK HEATER SUPPORT
UNDER HWH
40Ø SWING
CHECK VALVE40Ø BALL
VALVE
40Ø PRESSURE
RELIEVE VALVE
20Ø NG BALL
VALVE
HOT WATER CIRCULATING PUMPS x 2.
REFER TO DETAIL
25 BRONZE SWING CHECK VALVES x 2
25 BRONZE VALVES x 4
40Ø CW
25Ø HWR
40Ø
CW
200Ø STAINLESS STEEL FLUE PIPE
SIGN: THIS TMV REQUIRES
REGULAR SERVICING
SIGN: THIS TMV REQUIRES
REGULAR SERVICING
SIGN: THIS TMV REQUIRES
REGULAR SERVICING
DRAUGHT DIVERTER
7
A
8
B
6
5
C D E F G H I
7
J
8
6
5
4
3
2
1
A B C D E F G H I
4
3
2
1
J
All dimensions to be verified on site/s prior to commencment of
on-site work and/ or off-site prefabrication. Figured dimension to
be taken in preference to scaled dimensions. This drawing is
copyright and remains the property of JHA Consulting Engineers.
Reproduction in whole or part of these drawings without written
consent constitutes an infringment of copyright.
JOB No. DRAWING No. REV
DRAWN CHECKED APPROVED
TITLE
Rev Date VerifiedDescription
Description FromDrawing NumberRev
REFERENCE DRAWINGS
REVISIONS / AMENDMENTS
SCALE @ A1
PROJECT
ARCHITECT
CHILD CARE CENTRE
823-825 BOTANY ROAD
ROSEBERY, NSW 2018
LOT 1 DP838607
189 Kent Street
Sydney, NSW 2000
www.sbarchitects.com.au
CONSULTANT
Level 3, 146 Arthur Street,
North Sydney
NSW 2060
Australia
+61 (02) 9437 1000
www.jhaservices.com
HYDRAULIC SERVICES
DETAIL SHEET 2
N.S. B.S. P.C. N.T.S.
150049 H401 A
TENDER ISSUENOT TO BE USED FOR CONSTRUCTION
A 12.11.15 B.S.TENDER ISSUE
FHR
FHR
25
FHR
25
FHR
ROH
ROH
ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH
ROH
ROH
ROH
RO
H
RO
H
ROH
ROH
ROH
27m
23m
H
ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROHROH
ROHROH
ROHROH
ROHROH
ROHROH
ROHROH ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROH
60m
ROH
ROH
ROH
ROH
ROH
RO
H
ROH ROH
RO
H
18.4m
10000
EX FH
FIRE BRIGADE
PUMPING APPLIANCE
RO
H
RO
H
ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROH
27m
7
A
8
B
6
5
C D E F G H I
7
J
8
6
5
4
3
2
1
A B C D E F G H I
4
3
2
1
J
All dimensions to be verified on site/s prior to commencment of
on-site work and/ or off-site prefabrication. Figured dimension to
be taken in preference to scaled dimensions. This drawing is
copyright and remains the property of JHA Consulting Engineers.
Reproduction in whole or part of these drawings without written
consent constitutes an infringment of copyright.
JOB No. DRAWING No. REV
DRAWN CHECKED APPROVED
TITLE
Rev Date VerifiedDescription
Description FromDrawing NumberRev
REFERENCE DRAWINGS
REVISIONS / AMENDMENTS
SCALE @ A1
PROJECT
ARCHITECT
CHILD CARE CENTRE
823-825 BOTANY ROAD
ROSEBERY, NSW 2018
LOT 1 DP838607
189 Kent Street
Sydney, NSW 2000
www.sbarchitects.com.au
CONSULTANT
Level 3, 146 Arthur Street,
North Sydney
NSW 2060
Australia
+61 (02) 9437 1000
www.jhaservices.com
HYDRAULIC SERVICES
GROUND FLOOR
FIRE HYDRANT & FIRE HOSE
REEL RUN OF HOSE
N.S. B.S. P.C. 1:100
150049 H500 A1 : 100-A1 1 : 200-A3
2 1 0 2 4 6 8 m
TENDER ISSUENOT TO BE USED FOR CONSTRUCTION
A 12.11.15 B.S.TENDER ISSUE
FHR
FHR
25
FHR
25
FHR
ROH
ROHROH
ROH
ROHROH ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH 60m
ROH
ROH
ROH
ROH
ROH
ROH
ROH
60m
ROH
ROH
RO
HR
OH
RO
H
ROHROH ROH ROH ROH ROH ROH ROH
ROHROH
ROHROH
ROH60m
18.4m
ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH ROH 36m
RO
HR
OH
RO
H
ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROH
31m
ROH
ROH
ROH
ROH
ROH
ROH
ROH
ROH 30m
7
A
8
B
6
5
C D E F G H I
7
J
8
6
5
4
3
2
1
A B C D E F G H I
4
3
2
1
J
All dimensions to be verified on site/s prior to commencment of
on-site work and/ or off-site prefabrication. Figured dimension to
be taken in preference to scaled dimensions. This drawing is
copyright and remains the property of JHA Consulting Engineers.
Reproduction in whole or part of these drawings without written
consent constitutes an infringment of copyright.
JOB No. DRAWING No. REV
DRAWN CHECKED APPROVED
TITLE
Rev Date VerifiedDescription
Description FromDrawing NumberRev
REFERENCE DRAWINGS
REVISIONS / AMENDMENTS
SCALE @ A1
PROJECT
ARCHITECT
CHILD CARE CENTRE
823-825 BOTANY ROAD
ROSEBERY, NSW 2018
LOT 1 DP838607
189 Kent Street
Sydney, NSW 2000
www.sbarchitects.com.au
CONSULTANT
Level 3, 146 Arthur Street,
North Sydney
NSW 2060
Australia
+61 (02) 9437 1000
www.jhaservices.com
HYDRAULIC SERVICES
FIRST FLOOR
FIRE HYDRANT & FIRE HOSE
REEL RUN OF HOSE
N.S. B.S. P.C. 1:100
150049 H501 A1 : 100-A1 1 : 200-A3
2 1 0 2 4 6 8 m
TENDER ISSUENOT TO BE USED FOR CONSTRUCTION
A 12.11.15 B.S.TENDER ISSUE