  • 7/28/2019 Review of "The concept of floating electrode for contact-less electrochemical measurements: Applicationtion to reinforcing steel bar corrosion in concrete"

    1/13

    M. Keddam a, X.R. Nvoa b, V. Vivier

    Corrosion Science 2009

  • 7/28/2019 Review of "The concept of floating electrode for contact-less electrochemical measurements: Applicationtion to reinforcing steel bar corrosion in concrete"

    2/13

    Terminology Background Introduction Experimental Set-up

    Objectives Findings Numerical Modelling Discussion Authors Conclusions

    Critical Review Strengths of the Paper Weaknesses Potential for Further Work

  • 7/28/2019 Review of "The concept of floating electrode for contact-less electrochemical measurements: Applicationtion to reinforcing steel bar corrosion in concrete"

    3/13

    Corrosion is the degradation of amaterial due to reactions with itsenvironment. A current is inducedon the surface of rebar whencorrosion is actively taking place.

    Electrochemical Impedance Spectroscopy (EIS) Impedance is the ability to resist the flow of current, like resistance, but

    is more applicable when alternating current (a.c.) is used.

    Thepolarization resistance, Rp, is the low frequency limit of theimpedance; this provides information about corrosion.

    An electrically f loating electrode (EFE) is one that is not directlyconnected to the object under study (the reinforcing steel in this case)

  • 7/28/2019 Review of "The concept of floating electrode for contact-less electrochemical measurements: Applicationtion to reinforcing steel bar corrosion in concrete"

    4/13

    Use of EIS in Literature for CorrosionStudies in Reinf. Concrete 3-electrode electrochemical cell is

    used as the model Working electrode is the metal

    under study Calcium hyroxide models the

    concrete environment Direct contact to the metal is

    necessary Commercial potentiostat used

    for measurements Analysis of data is well known

    electrical theory

    people.clarkson.edu/~samoy/Corrosion_EIS.htm

    http://people.clarkson.edu/~samoy/Corrosion_EIS.htmhttp://people.clarkson.edu/~samoy/Corrosion_EIS.htmhttp://people.clarkson.edu/~samoy/Corrosion_EIS.htmhttp://people.clarkson.edu/~samoy/Corrosion_EIS.htmhttp://people.clarkson.edu/~samoy/Corrosion_EIS.htmhttp://people.clarkson.edu/~samoy/Corrosion_EIS.htm
  • 7/28/2019 Review of "The concept of floating electrode for contact-less electrochemical measurements: Applicationtion to reinforcing steel bar corrosion in concrete"

    5/13

    The feasibility of using an EFE is explored to examinethe electrochemical behavior of an electronicallyconducting body immersed in an electrolytic mediumthrough impedance (EIS) measurements.

    Reinforced concrete is the subject of this paper,however, the EFE is applicable to a variety of othersystems and can be used to investigate: Corrosion behavior metallic particles in zinc-rich paints

    Conductability of metallic particles in suspension

    The ability of micro electrodes to probe within aprotective coating

  • 7/28/2019 Review of "The concept of floating electrode for contact-less electrochemical measurements: Applicationtion to reinforcing steel bar corrosion in concrete"

    6/13

    EIS was performed

    using two different

    methods

    Three electrodecell used in

    literature

    Four electrodecell being

    Investigated

  • 7/28/2019 Review of "The concept of floating electrode for contact-less electrochemical measurements: Applicationtion to reinforcing steel bar corrosion in concrete"

    7/13

    To investigate the effect of cover thickness on theimpedance spectra of a 4-electrode system

    To estimate the potential of the bar-cement interfaceindirectly based on its contribution to the current andpotential distributions between the measuring electrodes

    by comparing data collected to numerical simulations.

    Note that the analysis was done by comparing the comparingexperimental impedance data to numerical simulationsbased on the frequency dependent distribution of potential

    and current computed by a 3-D finite element method(FEM) software. Moreover, a comparison was done withprevious results simulated with a 2-D model

  • 7/28/2019 Review of "The concept of floating electrode for contact-less electrochemical measurements: Applicationtion to reinforcing steel bar corrosion in concrete"

    8/13

    Nyquist Plot where

    the imaginary part

    of the impedance is

    plotted against thereal part for different

    frequencies. The Rp

    is the diameter of

    each plot.

  • 7/28/2019 Review of "The concept of floating electrode for contact-less electrochemical measurements: Applicationtion to reinforcing steel bar corrosion in concrete"

    9/13

    3-D model

  • 7/28/2019 Review of "The concept of floating electrode for contact-less electrochemical measurements: Applicationtion to reinforcing steel bar corrosion in concrete"

    10/13

    The distance between the two reference electrodes is agood approximation of the rebar length sensed.

    At high frequencies the injected current flowspreferentially within the steel bar.

    The apparent Rp of the reinforcing bar, measured bythe 4-electrode technique, can be related to theeffective Rp by considering the concrete resistivity.

  • 7/28/2019 Review of "The concept of floating electrode for contact-less electrochemical measurements: Applicationtion to reinforcing steel bar corrosion in concrete"

    11/13

    Within realistic ranges of concrete resistivity and polarisationresistance values, the technique can be used for extracting meaningfulimpedance characteristics of the reinforcement bar

    Why is this important?

    Cross-section of Reinforcing Bar

    (no corrosion)

    Charge, e-

    from applied, a.c.current

    Longitudinal Section of Reinforcing Bar

    (with corrosion)

    Applied a.c. current is interrupted, at pitand d.c. current now generated by

    corrosion

    A.C. CurrentD.C. Current

  • 7/28/2019 Review of "The concept of floating electrode for contact-less electrochemical measurements: Applicationtion to reinforcing steel bar corrosion in concrete"

    12/13

    Strengths of paper Interesting and relevant research topic Thorough and clear description of 4-electrode experiment (which

    was my primary interest here)

    Weaknesses of paper

    Traditional 3-electrode EIS was done as part of the experimenthowever, no mention of it was made in the presentation of results oranalysis.

    Lack of background information on the numerical analysisconducted, the presentation of which was heavy with electrical

    jargon and difficult to follow.

    Potential for further work As stated in the paper, the contact-less technique can be extendedto the detection and characterisation of corrosion on the surfaces ofembedded reinforcing steel bars

  • 7/28/2019 Review of "The concept of floating electrode for contact-less electrochemical measurements: Applicationtion to reinforcing steel bar corrosion in concrete"

    13/13

    THANK YOU!