Today’s building automation market●The market is growing because of:

● Rising energy costs

● Political and social push to reduce energy use and Green House Gas emissions.

●Key components of building automation:● Control of HVAC & lighting

● Support of standard based protocols: BACnet, Enocean, Zigbee, CANbus

●Market requirements:● Cost-effective (fast payback)

● Easy and fast deployment for the retrofit market

● 98% of buildings are under 100,000 ft² / 10,000 m²● Require low-cost solutions that negate the need for

expensive building automation software & server.

Energy prices

Energy Efficiency Regulations

Energy ratio for HVAC & lighting

Up to

Page 3: Retail Energy Analytics and Control Technology R.E.A.C.T

Introducing: R.E.A.C.TRetail Energy Analytics & Control Technologies

Lightingmanagement

Energymanagement

Supervision

HVACmanagement

Innovative Control Solutions forSmall & Medium size building

Lower Total Installed Cost

Increase Energy Savings with Improved Comfort

Simplified Automation

Open Systems

Improve customer ROI

Small & Medium Size Buildings<100,000 sqft< 10,000 m2

Non Intrusive Retrofit

Offer values

Benefits

Page 4: Retail Energy Analytics and Control Technology R.E.A.C.T

Markets Served by R.E.A.C.T

Page 5: Retail Energy Analytics and Control Technology R.E.A.C.T

Product Overview

Page 6: Retail Energy Analytics and Control Technology R.E.A.C.T

Simplified Automation

All in One Web BMS

Supervision

Terminal Controllers & 3rd party vices

Dashboards & Maps

Pre-configure objects…

Graphical programming, Scripting , SchedulerProgramming

VT7000

Page 7: Retail Energy Analytics and Control Technology R.E.A.C.T

System Architecture

Page 8: Retail Energy Analytics and Control Technology R.E.A.C.T

Product Ecosystem

End Device

Core System Manager‐ REACT 

Controllers Input /Output Room Controllers

Site Manager with I/O

WiredI/O

Page 9: Retail Energy Analytics and Control Technology R.E.A.C.T

Total Installed Cost

Application

Current Standalone Installation

Installation

R.E.A.C.T. Installation

R.E.A.C.T.Panel

Sensing Components+

Equipment Controller+

Accessories+

Integration/CommunicationDevice

Higher Total Installed Cost Lower Total Installed Cost

Specialized LaborX

Complex installation including multiple devices requiring additional wiring and specialized software

tools.

Non-AutomationSpecialized Labor

x Short, Simple Installation

with no software Tools

Page 10: Retail Energy Analytics and Control Technology R.E.A.C.T

ISO 9001 & ISO 14001 CERTIFIED

R.E.A.C.T – Wireless Core Manger

• Provides a low cost, simple supervisory controller for system scheduling and facility management.

• Can manage a system(s) of up to 60 wall controllers of any terminal equipment type - Fan Coils, RTU’s and Heat Pumps.

Key Controller Features:• Master System Schedule Capability• Simple, LCD Menu Driven, Out of Box Solution• Central Set point Adjustment • System Mode Management • Global Overrides• Global Outdoor Temperature Broadcast• Low Level Central Alarm Reporting• Password Protected - Lockable Front Keypad • Heat and Cool System Lockouts – Energy

Savings!

Page 11: Retail Energy Analytics and Control Technology R.E.A.C.T

Wireless Network Solutions

Page 12: Retail Energy Analytics and Control Technology R.E.A.C.T

Programmable Core Panel

Page 13: Retail Energy Analytics and Control Technology R.E.A.C.T

Mini-BMS for Small Buildings

Small & Medium Size Buildings

<100,000 sqft / 10,000 m2

2Low-cost, fully programmable HVAC, lighting and metering control with local and remote management via internal software

Mini-BMS for small buildings

Page 14: Retail Energy Analytics and Control Technology R.E.A.C.T

Why is the mid-marketunderserviced?>Heavy fixed costs

>LOTS of wiring•Takes time•Adds labour & repair•Adds downtime

Payback istoo long

Realities of Building Automation

LightingGateway

HVACGateway

SystemGateway$$$

Software or server$$$$

BMS user

interface

Typical BAS architecture

IP/ETHERNET

Controllers

End-devices

HVACLighting

$$ $$

Page 15: Retail Energy Analytics and Control Technology R.E.A.C.T

HVAC, Lighting, Metering, Access and other applications

$$ $$

Faster installation, integration & payback

LightingGateway

HVACGateway

SystemGateway$$$

Software or server$$$$

BMS user interface

Typical BAS architecture

IP/ETHERNET

Our architecture

Controllers

End-devices

HVACLighting

ZigBeeEnOcean Wired

IP/ETHERNET

Web BMSOptionalThird party BACnet IP

BMS

Page 16: Retail Energy Analytics and Control Technology R.E.A.C.T

You can go…>Wireless>Wired & wireless

>Or just wired•I/O Extenders available

Occupancy sensor

Light sensor

Air conditioning

Heating

Temp. control

At the room level

Light relay

Light switch

CO2 sensorKeycard reader

Sub-meter

Page 17: Retail Energy Analytics and Control Technology R.E.A.C.T

Simplified AutomationMonitoring & Management> HVAC, Lighting, Occupancy, Metering and more.

Included with the hardware> Hosted by the controllers> No dedicated server> No software to install> No license fees

Access> Local access through the LAN > Remote access online using a web browser> Can sit under a third party BACnet system

IP/ETHERNET

Web BEMS

Internet

LAN

Embedded web server

Page 18: Retail Energy Analytics and Control Technology R.E.A.C.T

Customized Dashboard

Schneider Electric – Exchange 2012

View trends

Monitor systems and sensors‐ Temperature ‐ Lighting‐ Humidity ‐ Occupancy‐ CO2‐ And more...

Monitor consumption‐ Electricity‐ Gas‐Water‐ And more...

Track energy savings

Compare ratios

Page 19: Retail Energy Analytics and Control Technology R.E.A.C.T

MapsImport maps of your buildings, draw zones and see system status within those zones.

Quickly see how your building is doing- Import building, floor and zone maps.- Draw color-coded zones.- Drag-and-drop your objects onto themaps.

- Thermostats- Switches- Sensors- Etc.

- Associate colors to events.- The colors will tell you if you’re in thegreen.

Simplified Automation

Page 20: Retail Energy Analytics and Control Technology R.E.A.C.T

SchedulesUse schedules to regulate your HVAC and lighting systems according to building use. You can create schedules for

each zone.

Trigger events according to the time ofday and day of the week- Pre-heat or pre-cool space in the morning.- Reduce consumption at peak times.- Close or dim systems in empty rooms orzones.- Close systems for the evening and night.- And more....

Simplified Automation

Page 21: Retail Energy Analytics and Control Technology R.E.A.C.T

Typical Applications

Page 22: Retail Energy Analytics and Control Technology R.E.A.C.T

Water based heating systems● Perimeter heating with radiators● Perimeter heating with fan coils

School schedules● Can’t disturb classes● Can’t afford overtime pay

Out-buildings

Hazards in the walls● Dust or asbestos fears

Tight budget● Fixed costs of front-end, servers

and gateways limiting the ROI?

Proven solution● Smart wireless actuator● Wireless room and terminal controllers

Wireless retrofit during school days● Limit wiring to a minimum● Limit invasiveness and disturbance

Bring them in wirelessly with ZigBee

Avoid renovation, repair & repaint work● Keep parents and administrators happy

Pre-Installed Internal Software● No license fee! Low fixed costs!● Scalable to Third-Party BMS via BACnet IP,

oBIX

School NeedsSmall Building Solution

Page 23: Retail Energy Analytics and Control Technology R.E.A.C.T

Unit ventilator / fan coil school retrofit jobWireless manager(one unit can manage many zones)

If there are no old stats or existing wiring isn’t usable, place SEC-TE inside unit

Swap old stat with

Tstat

Light relay with dimming

Light sensor and light switch

LANInternal Web Server

Unit ventilator or fan coil

Page 24: Retail Energy Analytics and Control Technology R.E.A.C.T

Remote-Buildings & Portable Classrooms

Schools run out of space and use out-buildings to fill gap● Integrating these buildings into an automation system is difficult & costly● Managers can integrate portable classrooms easily and at a low cost● Manage multiple buildings from the monitor or use larger third-party systems

Up to 900 feet line of sight

Internal Web Server

internet

internet

Page 25: Retail Energy Analytics and Control Technology R.E.A.C.T

Energy savings● Show me the money!

Comfort● For guests and staff

Visability● How do I know it works?

Can’t close down entire floors● The downtime cost is real● Every room out of inventory is

a loss

Optimize your systems with many tools● Scripting, graphical programming,

dashboards, map sections, etc.

Precise, programmable control● For HVAC, lighting, occupancy & more● Promote your brand with the slick SE8000

Building Expert● Metering integration● Integration to other B.A.S. systems

Wireless retrofit options● In-and-out with minimal wiring● Little inventory downtime● Real ROI for hotel management

Hotels & Lodging NeedsR.E.A.C.T.

Page 26: Retail Energy Analytics and Control Technology R.E.A.C.T

Use case: simple & complete automationObjectives: happy guests & bottom line● Control heating and cooling costs● Get your guests in the comfort zone● Remote management for more efficiency

Solution● Wireless Control for HVAC in each room● Embedded PIR motion sensor (optional) sets

temperature for occupied/unoccupied mode● Guests can adjust setpoints for comfort● Networking and integration performed by

MPM devices each handling several zones● Management can set high and low limits

according to schedules● Management can put rooms into vacant mode

for maximum energy savings

Room 205

Room 207

Room 209

Room 211

Room 204

Room 206

Room 208

Room 210

FC, HP

Page 27: Retail Energy Analytics and Control Technology R.E.A.C.T

Room 205

Use case: simple & complete automation

Solution (cont’d)● Management Building Expert● Can import hotel floorplans and define

custom zones with color codes for user-friendly visualizations

Scale over time with wireless● Easily add points with EnOcean and

ZigBee● Lighting control● Additional sensors● Other applications

● Can integrate wireless keycard reader to set occupied/unoccupied mode

Light relay

Keycard reader

Page 28: Retail Energy Analytics and Control Technology R.E.A.C.T

Comfort, Efficiency & Branding

Swap old stat with VT8000

PIR motion sensor included

my Hotel

Create loyalty with your brandCustomizable cover, color, language and screensaver!

Direct integration to BACnet and LON

Fan coil, heat pump or other system

Or integration via R.E.A.C.T.

Building Expert for smallhotels and motels. Integrateto other systems for largerbuildings.

Use relay pack for line voltage fan coils

LAN

Page 29: Retail Energy Analytics and Control Technology R.E.A.C.T

Typical retail scenarioCafé

Page 30: Retail Energy Analytics and Control Technology R.E.A.C.T

●To improve efficiency with other applications, just add more wireless points.● Once REACT Panel is in place, scalability

becomes easy and allows system improvements over time as customer needs, regulations and benchmarks evolve

● Wireless makes adding points easy for a wide variety of applications● Lighting control using relays, switches,

light sensors and motorized blinds● Sensors: occupancy, CO², H%, etc.● Metering

●This creates return business and servicing opportunities● Energy savings can be reinvested into

further improvements at minimal cost because installation labor is greatly reduced

Need lighting? Occupancy? Metering?

Wireless inputs & outputs● Up to 24 ZigBee peripherals per MPM● Up to 128 EnOcean points per MPM

Page 31: Retail Energy Analytics and Control Technology R.E.A.C.T

Standard Application Basic Small Building Solution

Page 32: Retail Energy Analytics and Control Technology R.E.A.C.T

32

R.E.A.C.T

●Economical●Easy to Estimate● Increased savings●Quicker Payback●Little or No disruptions●Retrofit or New

Page 33: Retail Energy Analytics and Control Technology R.E.A.C.T

● Small retail outlet● 4 RTU’s● Two Lighting Zones

Example Estimation #1

Page 34: Retail Energy Analytics and Control Technology R.E.A.C.T

● 4 RTU Thermostats● One REACT Panel connected to LAN

Example Estimation #1

LAN

Page 35: Retail Energy Analytics and Control Technology R.E.A.C.T

35

●REACT CORE PANEL : R-YKL-014-S $2800.00●Basic Panel, No extra relays

●Four Zigbee Thermostats $2000.00

Example Estimation #1

Page 36: Retail Energy Analytics and Control Technology R.E.A.C.T

Example Estimate – Coffee Shop● 2 Rooftops with CO2 economizer● 4 Temperature Monitoring and alarming of Freezers/Coolers● 3 coffee brewers● Metering

Page 37: Retail Energy Analytics and Control Technology R.E.A.C.T

37

●REACT CORE PANEL : R-YKL-112-S $2840.00●Basic Panel, One extra relay

●Two Zigbee Thermostats $1000.00●Specialty Sensors

●CO2 2 x $400 = 800.00●Plate Sensors for coolers 4 x $100 = 400.00

●Power Monitoring Package $2900.00

Example Estimation #2

Page 38: Retail Energy Analytics and Control Technology R.E.A.C.T

38

●REACT CORE PANEL : R-YKL-014-S $2800.00●Basic Panel, No extra relays

●Four Zigbee Thermostats $2000.00

Example Estimation #1

Page 39: Retail Energy Analytics and Control Technology R.E.A.C.T

39

REACT + Analytics =E2Optex

●E2Optex

●Continuous Commissioning and Automatic Analytical Tool ●Automatically identifies issues●Analyzes performance and costs●Predicts, detects and alerts of equipment failures

Page 40: Retail Energy Analytics and Control Technology R.E.A.C.T

40

E2Optex – Examples of what we find.Equipment not keeping up with demand and identifies COST

Page 41: Retail Energy Analytics and Control Technology R.E.A.C.T

41

E2Optex – Examples of what we find.Extensive electrical demand and identifies against Ideal electrical demand

Page 42: Retail Energy Analytics and Control Technology R.E.A.C.T

42

E2OptexAnalyzes and visualizes the electrical use against ideal profile with COST

Page 43: Retail Energy Analytics and Control Technology R.E.A.C.T

43

E2-Optex System Architecture Examples

SCADA

EcoBeeServer

E2-Optex Server(Onsite or Remote)

CSV SQLCSV

APIHTML

Page 44: Retail Energy Analytics and Control Technology R.E.A.C.T

In Summary Slide for Contractors(remove or change for endusers or mixed group

Partners Benefits• Create new opportunities • Lowest install cost• Retrofit Champion• Enable Services Offering

Offer Value

• Simplified Automation• Open system • Non Intrusive Retrofit

• All in one: Sensor & Control• HVAC Control Application• Open Communication

Innovative Control Solutions for Small & Medium Size Buildings

Offer Value