Results of Investigation of Unit 2 Reactor Building Operation Floor Utilizing a Gamma Camera February 22, 2013 Tokyo Electric Power Company < Reference >

Upload: others

Post on 04-Jul-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Results of Investigation of Unit 2 Reactor Building …...Gamma camera Gamma camera γ-eyeⅡ) Platform Generator Repeater Main Anti-earthquake Building Operation PC Upper part of

Results of Investigation of Unit 2 Reactor Building Operation Floor Utilizing a Gamma Camera

February 22, 2013Tokyo Electric Power Company

< Reference >

Page 2: Results of Investigation of Unit 2 Reactor Building …...Gamma camera Gamma camera γ-eyeⅡ) Platform Generator Repeater Main Anti-earthquake Building Operation PC Upper part of

2

Outline of InvestigationPurposeAs the atmosphere dose in the operation floor (fifth floor) of Unit 2 Reactor Building needs to be reduced in order to prepare for fuel removal planned in the future, decontamination and shielding measures are being planned. For effective and efficient planning of measure implementation, the relative intensity and distribution of radiation on the surface were investigated mainly in the upper part of the reactor well utilizing a gamma camera.

InvestigationA platform was installed in the east side of Unit 2 Reactor Building and the radiation released from the target surface was measured at the blow-out panel opening on the operation floor utilizing a gamma camera (γ-eye II developed by the JAEA). The investigation results will beanalyzed to obtain the radiation distribution on the target surface.

Number of workers involvedTEPCO: 7, Cooperative company: 13

Date and timeThursday, February 21, 2013 from 9:00 AM to 4:55 PM

Maximum radiation exposure dose0.75mSv/person (Planned exposure dose: 4mSv)

Page 3: Results of Investigation of Unit 2 Reactor Building …...Gamma camera Gamma camera γ-eyeⅡ) Platform Generator Repeater Main Anti-earthquake Building Operation PC Upper part of

3

Investigation

The numbers provided above are the dose rates obtained on June 13 (Unit: mSv/h). The figure is a simulated image. In actual, images were acquired by horizontally dividing the target surface into three parts.

: Fence

Unit 2 operation floor

フェンス

JAEA γ-eye II and the platform

Platform

Crane

Radio

Camera location: 2.3m from the outer wall surface, 3.65m from the floor surface of the operation floor

Gamma camera

Gamma camera (γ-eyeⅡ)

Platform

Generator

Repeater

Main Anti-earthquake

Building

Operation PC

Upper part of reactor well

Blow-out panel opening(W6,000mmxH4,300 mm)

Unit 2 Operation Floor

RPV

Fence

Fuel handling machine

Page 4: Results of Investigation of Unit 2 Reactor Building …...Gamma camera Gamma camera γ-eyeⅡ) Platform Generator Repeater Main Anti-earthquake Building Operation PC Upper part of

4

Investigation Results (Preliminary)

Investigation results of Unit 2 operation floor will be analyzed to obtain the radiation distribution of the target surface. The analysis is estimated to be completed in about a month.

Dose rate

High

Dose rates measured from the gamma camera position

Low