results of hydrophobic acrylic iol insertion through corneal microincisions smaller than 2.0 mm

12
Results of Hydrophobic Acrylic IOL Insertion through Corneal Microincisions Smaller than 2.0 mm Tomoichiro Ogawa, Takuya Shiba Hiroshi Tsuneoka Jikei University School of Medicine, Tokyo, Japan Authors have no financial interests

Upload: aurek

Post on 20-Mar-2016

34 views

Category:

Documents


1 download

DESCRIPTION

Results of Hydrophobic Acrylic IOL Insertion through Corneal Microincisions Smaller than 2.0 mm. Tomoichiro Ogawa, Takuya Shiba Hiroshi Tsuneoka Jikei University School of Medicine, Tokyo, Japan. Authors have no financial interests. iMics1. 6mm. Y-60H. AF-1 iMics1 ( HOYA ). - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Results of Hydrophobic Acrylic IOL Insertion through Corneal Microincisions Smaller than 2.0 mm

Results of Hydrophobic Acrylic IOL Insertion

through Corneal Microincisions Smaller than

2.0 mmTomoichiro Ogawa, Takuya Shiba

Hiroshi Tsuneoka

Jikei University School of Medicine, Tokyo, Japan

Authors have no financial interests

Page 2: Results of Hydrophobic Acrylic IOL Insertion through Corneal Microincisions Smaller than 2.0 mm

AF-1 iMics1 ( HOYA )• Hydrophobic acrylic intraocular lens (IOL)• Implanted through corneal microincisions

Y-60HY-60HiMics1iMics16mm

Page 3: Results of Hydrophobic Acrylic IOL Insertion through Corneal Microincisions Smaller than 2.0 mm

AF-1 iMics1 ( HOYA )• Injector : ISH004(HOYA)• Cartridge : Type-N18 ( HOYA )

oPreferred incision size:Cornea, 2.0 mm; Sclera cornea, 1.8 mm

PurposeTo evaluate the safety and efficacy of

cataract surgery with implantation of the AF-1 iMics1 IOL through a corneal microincision

Page 4: Results of Hydrophobic Acrylic IOL Insertion through Corneal Microincisions Smaller than 2.0 mm

Subjects and Method• May - August 2009• Jikei University Hospital• Procedures: 69 eyes

• 1.7-mm ( inner scale ) corneal incision: 47 eyes• 2.0-mm ( inner scale ) corneal incision: 22 eyes

• Operative method• 1.4-mm temporal corneal incision • Bimanual phacoemulsification• Incisions enlarged to 1.7 or 2.0 mm • Implant AF-1 iMics1

Page 5: Results of Hydrophobic Acrylic IOL Insertion through Corneal Microincisions Smaller than 2.0 mm

Variables examined• Incision size ( before and after IOL

implantation )• Tsuneoka microincision gauge ( ASICO )

• Increased width of corneal incision after IOL implantation

• Surgery-induced corneal astigmatism ( Cravy method )• 1 month postoperatively

• Operative complications• Postoperative complications

Page 6: Results of Hydrophobic Acrylic IOL Insertion through Corneal Microincisions Smaller than 2.0 mm

0.310.22 0.25

0.1

0.2

0.3

0.4

1.9mm 2.2mm Y-60H (2.2mm)

(mm) *

**1.7 mm 2.0 mm

Results

**2008. Ogawa. ESCRS.

2.272.052.09

1.791.5

1.7

1.9

2.1

2.3

pre post pre post

1.7mm 2.0mm

(mm)

Wound width

Increased wound width

P=0.0025Mann-Whitney U-test

Page 7: Results of Hydrophobic Acrylic IOL Insertion through Corneal Microincisions Smaller than 2.0 mm

Results

0.031

-0.057

0.039

0.580

0.200

-0.1

0.1

0.3

0.5

1.9mm 2.2mm Y-60H(2.2mm)

SA60AT(C)(2.2mm)

SN60WF(C)(2.2mm)

(D)

** ** **

* NSSurgery- induced corneal

astigmatism

*Mann-Whitney U-test

**2008. Ogawa. ESCRS.

1.7mm 2.0mm

Page 8: Results of Hydrophobic Acrylic IOL Insertion through Corneal Microincisions Smaller than 2.0 mm

Results  1.7 mm 2.0 mm

Posterior capsulerupture 0 eye/47 1 eye/22Wound

self-healing 100% 100%

  1.7 mm 2.0 mmIOL decentration 0% 0%

Cysticmacula edema 0% 0%

Woundself-healing 100% 100%

Operative complications

Post- operative

complications

Page 9: Results of Hydrophobic Acrylic IOL Insertion through Corneal Microincisions Smaller than 2.0 mm

DiscussionsPosterior capsule rupture

Tip of cartridge is too deep in anterior chamber and too close to posterior capsule

Insertion of cartridge

Tip of cartridge

Page 10: Results of Hydrophobic Acrylic IOL Insertion through Corneal Microincisions Smaller than 2.0 mm

Tacking tips of both forward and back hapticsО Full length of IOL is greater than that of other foldable

1-piece IOLsAF-1 iMics1 is stiffer

AF-1 iMics1 SN60WF

Full length is greater

Page 11: Results of Hydrophobic Acrylic IOL Insertion through Corneal Microincisions Smaller than 2.0 mm

IOL is released near posterior capsule

Posterior capsule ruptureIOL implantation

IOL goes through posterior capsule

Posterior capsule ruptures

Page 12: Results of Hydrophobic Acrylic IOL Insertion through Corneal Microincisions Smaller than 2.0 mm

ConclusionAF-1 iMics1 ( HOYA )

• Implanted through corneal incision < 2.0 mm• Little surgery-induced astigmatism • Wound self-healing• Carefully position tip of cartridge