responsibility of the builder/ownernewhampshireloghomes.com/.../photo-albums-plans/... · 8x8 df...
TRANSCRIPT
GARAGE DOOR B.O
9'-0" X 8'-0"
GARAGE DOOR B.O
9'-0" X 8'-0"
GARAGE DOOR B.O
9'-0" X 8'-0"
ECC2454-2T
EC
C36
54E
CC
3654
EC
C24
48T
ECC3654-2
6'-0 3/4" x 4'-6 3/4"
ECC3642-2
6'-0 3/4" x 3'-6 3/4"
FIXED 12x72 FIXED 12x72SCS4-120Q611
14' SLIDER14'-0 3/4" x 6'-11"
SCHD-50611FO
5'-0 3/4" x 6'-11"
ECC3036
2'-6 3/4" x 3'-0 3/4"
ECC3054-2
5'-0 3/4" x 4'-6 3/4"
EC
C24
36-3
PATIO......................................... 1023BASEMENT............................................. 1955GARAGE............................................... 1071DECK/PORCH AREA.......................................... 1328
UNHEATED AREAS:
HEATED TOTAL......................................... 4253
CARRIAGE SUITE......................................... 952SECOND FLOOR......................................... 1346FIRST FLOOR.......................................... 1955
HEATED AREAS:
SQUARE FOOTAGE
18 R
. @ 7
5/8
"17
T. @
10"
8'-0
"
6'-0
"
15'-6
"17
'-11"
2'-5 1/2"
14'-4
"
11'-10 3/4"
11'-3
3/4
"
12'-6"
18'-5"
6'-1
0"
15'-4
"
3'-8"
5'-0
"10
'-4"
3'-6
"1'
-0"
3'-9
3/4
"5'
-1 1
/4"
6'-8" 9'-3"
8'-6
1/2
"
10'-11 3/4" 2'-4" 5'-6" 4'-1/2"
10'-0" 17'-9 7/8" 18'-3" 20'-5/8" 8'-5 1/2"8'
-9 7
/8"
10'-0
"
12'-4
"
10'-5
1/2
"
12'-4
"
21'-2"
5'-5
"7'
-5 1
/4"
6'-2
3/4
"
5'-10" 12'-2" 6'-10 1/2"7 1/2" 6 1/2"
7 1/
2"7'
-5"
42'-1/2"
2'-3
"3'
-4"
6'-9
1/8
"3'
-4"
2'-3
"
5'-2" 5'-9 1/2" 5'-1 1/2"
2'-5" 1'-4" 6'-9" 1'-4"1'-3"
17'-4 1/8"
11'-1
"5'
-5 1
/8"
13'-1" 5'-5 1/8"
17'-8
"
24'-5" 18'-3" 17'-4 1/8"
11'-2"
5'-9 3/8"
5'-1"
2 1/
8"2'
-9"
6'-4
"2'
-0"
6'-0
"6'
-0"
5'-3
3/4
"3'
-3 3
/4"
7'-0
"11
'-5 1
/2"
15'-5
1/4"
11'-1/2" 6'-7" 12'-10 1/2"1 7/8"
7'-1/2" 4'-4" 7'-1/2"
2'-2
"2'
-4"
11'-6
1/2
"
FRAMING WITHLOG SIDING
FRAMING WITHLOG SIDING
3 STEPS DOWN
BENCH
POST LOCATIONS REQUIRED FORFUTURE ATTACHMENT OF CONNECTION
FROM HOUSE TO GARAGE
4X12 DF HEAVYTIMBER STAIRS
8X8 DF POST TOSUPPORT GIRDERLOFT LINE
ABOVE
FRAMING WITHLOG SIDING
12" RND CORNERPOST TO ROOF
8X8 DF POST CUTTO ACCOMODATE ANGLE
8X8 DF POST CUTTO ACCOMODATE ANGLE
10x10 DF PORCH POST@ GABLE PORCH ONLY
8x8 DF PORCH POST@ SHED PORCHES ONLY
8X8 DF POST CUTTO ACCOMODATE ANGLE
MAIN FLOOR PLAN
3-0
GABLEPORCH
OUTDOORLIVING ROOM
LAUNDRY/
MUDROOM
BU
ILT-
IN/
TELE
VIS
ION
6" PLU. WALL
3-0
GREATROOM
KITCHEN
D
W
DECK
GRILL
GABLEPORCH
3-0
8X12
DF
GIR
DE
R B
EA
M
PANTRY
GA
SFI
RE
PLA
CE
BUILDING GREEN:1) WHERE POSSIBLE, USE COMPACT FLUORESCENT LIGHTING.2) USE DURABLE ROOF COVERINGS SUCH AS STEEL OR FIBER CEMENT TO REDUCE THE NECESSITY FOR FUTURE ROOF COVERING REPLACEMENTS.3) THE USE OF FACTORY BUILT COMPONENTS REDUCES THE AMOUNT OF JOB SITE CUTTING FURTHER REDUCING WASTE.4) CHOOSE ENERGY STAR RATED APPLIANCES WHENEVER POSSIBLE.5) USE NATIVE PLANTS DURING LANDSCAPING TO REDUCE THE NEED FOR WATERING AND FERTILIZING.6) IN ROOF SYSTEMS AND EXTERIOR STUD WALLS, USE THE HIGHEST R-VALUE POSSIBLE.7) USE LOW-E WINDOWS TO REDUCE HEAT TRANSFER
UP
WOOD
FIREPLACE INSERT
GAS STARTER
CAUTION MUST BE EXERCISEDIN MAKING ANY CHANGES IN THIS PLAN. MINORCHANGES IN ONE AREA OF THE HOUSE COULDLEAD TO MAJOR PROBLEMS IN ANOTHER AREA.
RESPONSIBILITY OF THE BUILDER/OWNERTHESE DRAWINGS ARE IN PART DIAGRAMMATIC AND DO NOT SHOW INDETAIL HOW WORKMANSHIP, MATERIALS AND INSTALLATION OF THE MATERIALSINCLUDING THE FIXTURES AND EQUIPMENT ARE TO BE BROUGHT TOGETHERTO COMPLETE THE "WHOLE" STRUCTURE.
IT IS THE RESPONSIBILITY OF THE BUILDER/OWNER TO BUILD THESTRUCTURE TO COMPLY WITH ALL APPLICABLE NATIONAL, STATE,COUNTY AND CITY CODES AS THEY APPLY TO EACH COMPONENT
6" P
LUM
BIN
G W
ALL
NOTE:1) ALL REPRESENTATIONS OF FIXTURES, EQUIPMENT,
MATERIALS, ELECTRICAL, PLUMBING, FASTENERS, ETC.ON CLIENTS DESIGN ARE NOT INCLUDED WITH CLIENT'SPACKAGE PURCHASED FROM TENNESSEE LOG &TIMBER HOMES, INC. ONLY ITEMS SPECIFICALLY NOTEDIN TENNESSEE LOG & TIMBER HOMES, INC. PURCHASEAGREEMENT WILL BE INCLUDED IN THE MATERIALS LISTAND SUPPLIED TO THE CLIENT.
2) CONTRACTOR TO VERIFY ALL DIMENSIONSBEFORE BEGINNING CONSTRUCTION.
3) ALL INTERIOR STUD WALLS ARE NON-LOADBEARING.
4) ALL DOOR AND WINDOW ROUGH OPENINGSTO BE VERIFIED AS LOGS ARE BEING STACKED.OPENINGS MAY NEED TO BE ADJUSTED BYADDING OR DELETING DOOR AND WINDOWBUCKS OR BY CUTTING LOGS.
5) EXTREME CARE IN PRE-CUTTING LOG OPENINGSHAS BEEN TAKEN. THE OWNER/CONTRACTOR ISRESPONSIBLE FOR CHECKING AND ADJUSTINGOPENINGS WHEN STACKING LOGS.
DINING
3' FIR
E
RATED STEEL
DINING HUTCH
HOTTUB
SEE GARAGE PLANFOR ALL SIZES
OUTDOORLIVING
MA
KE
-UP
VA
NIT
Y
DOWNFOYER
MASTERBEDROOM
3-0
BATH
WALK-INCLOSET
3-0
2-4
DOORS & WINDOWSSUPPLIED BY OWNER
8X14 DF GIRDER BEAM
8X14 GIRDER BEAM
8X14 GIRDER BEAM
6080 ARCHTOPR.O. 75 1/2" x 99 1/2"
IM
DW
7'-8 5/8"
4'-8 1/2" 17'-2 3/4" 11'-3 3/8" 4'-0" 2'-0"
GA
SFI
RE
PLA
CE
ECC3654-2
6'-0 3/4" x 4'-6 3/4"
ECC3654-2
6'-0 3/4" x 4'-6 3/4"
EC
C32
362'
-8 3
/4"x
3'-0
3/4
"E
CC
3654
3'-0
3/4
"x4'
-6 3
/4"
DN
18 R
. @ 7
5/8
"17
T. @
10"
4'-1
/2"
11'-5/8"
4'-2 1/4" 4'-9 3/4" 4'-9 3/4" 4'-2 1/4"
S-1
S-1
S-2 S-2
S-3
S-3
S-4
S-4
4-2X4 POST TOSUPPORT RIDGE
CANTILEVER FLOOR JOISTSTO SUPPORT BALCONY
SHED DORMER
CH
IMN
EY
BEDROOM
SHED DORMER
8x14 GIRDER BEAM
2-8
LOFT
2-8
ROOF SLOPE
WALK-INCLOSET
6" P
LUM
BIN
G W
ALL
CLOSET
BATH
2-8
16" FLOOR TRUSS W/3/4" ADVANTECH SHEATHINGPREMIER HOUSE ROOF SYSTEMCONVENTIONAL GARAGE ROOF
HALL
SEE GARAGE PLANFOR ALL SIZES
BATH
SECOND FLOOR PLANNOTE:1) ALL REPRESENTATIONS OF FIXTURES, EQUIPMENT,
MATERIALS, ELECTRICAL, PLUMBING, FASTENERS, ETC.ON CLIENTS DESIGN ARE NOT INCLUDED WITH CLIENT'SPACKAGE PURCHASED FROM TENNESSEE LOG &TIMBER HOMES, INC. ONLY ITEMS SPECIFICALLY NOTEDIN TENNESSEE LOG & TIMBER HOMES, INC. PURCHASEAGREEMENT WILL BE INCLUDED IN THE MATERIALS LISTAND SUPPLIED TO THE CLIENT.
2) ALL SECOND FLOOR STUD WALLS CONSTRUCTEDTO CEILING HEIGHT. (TYP)
3) BOX IN FLOOR JOISTS WHERE PLUMBING LINES ARELOCATED AFTER PLUMBING IS INSTALLED.
4) CONTRACTOR TO VERIFY ALL DIMENSIONSBEFORE BEGINNING CONSTRUCTION.
5) ALL DOOR AND WINDOW ROUGH OPENINGSTO BE VERIFIED DURING FRAMING OF GABLESAND DORMERS.
12/12
H
1/8 OF W
1/4 OF W
TABLE R1001.17CRICKET DIMENSIONS
8/12
6/12
4/12
3/12
1/2 OF W
1/3 OF W
1/6 OF W
3-0
SCDH-5061
1
QUARTER SEGMENTABOVE
48 3/4" x 47 3/4" x 30 3/4"
QUARTER SEGMENTABOVE
48 3/4" x 47 3/4" x 30 3/4"
2-8
WALK-INCLOSET
OFFICE
ECC42HRDS ABOVE
ECC42HRDS ABOVE
BALCONY
5'-0 3/4" x 6'-11"SCDH-50611
3-0
ARCH SEGMENT ABOVE48 3/4" x 52 3/4" x 48 3/4"
OPEN TOAREA BELOW
ECC3672-26'-0 3/4" x 6'-0 3/4"
ECA3618
3'-0 3/4" x 1'-6 3/4"
EC
C36
54-2
6'-0
3/4
"x4'
-6 3
/4"
ECC32362'-8 3/4" X 3'-0 3/4"
ECC32362'-8 3/4" X 3'-0 3/4"
ECC3648-2
5'-0 3/4" x 4'-0 3/4"
ECC3048-2
5'-0 3/4" x 4'-0 3/4"
ECC32542'-8 3/4" x 4'-6 3/4"
ECC3048-2
5'-0 3/4" x 4'-0 3/4"
ECC3054-37'-6 3/4" x 4'-6 3/4"
ECC3054-2
5'-0 3/4" x 4'-6 3/4"
ECC32542'-8 3/4" x 4'-6 3/4"
FIXED 48X484'-0 3/4" x 4'-0 3/4"
FIXED 48X484'-0 3/4" x 4'-0 3/4"
FIXED 48X484'-0 3/4" x 4'-0 3/4"
16'-3 1/2"
5'-2
7/8
"13
'-8 1
/8"
17'-5 5/8"
16'-3 1/2" 6'-0"
3'-0
"
9'-1 1/2"
8'-8
"
21'-6 1/8"
7'-3 3/8" 9'-9"
5'-11" 6'-6 1/4" 9'-11 3/4"
5'-8
"
9'-1 1/2" 6'-9" 9'-8"
17'-2"
5 1/2"
7'-3 3
/8"
7'-1 1
/2"
5 1/2"
22'-5"
6'-6"
13'-8
"
18'-3 1/2" 10'-11 1/2" 4'-3/4" 10'-11 1/2" 3'-3 5/8"
2'-5
"9'
-7 5
/8"
16'-1
7/8
"
5'-1
1 3/
8"5'
-3"
7'-5
1/2
"6'
-6 1
/2"
14'-1
/2"
5'-6"
6" PLU
MBING W
ALL
ECC36543'-0 3/4" x 4'-6 3/4"
ECC36543'-0 3/4" x 4'-6 3/4"
ECC36543'-0 3/4" x 4'-6 3/4"
ECC3654
3'-0 3/4" x 4'-6 3/4"
11'-9 1/2"
4'-1
3/4
"
6'-8"
8'-6
"6'
-8"
5'-3
"7'
-8"
16'-5" 23'-4"
2'-0
"
9'-8" 8'-2 1/8"
15'-4
"
18'-4" 3'-6" 4'-0" 16'-0"
8'-9
3/4
"27
'-3 1
/4"
17'-10 1/8"
6'-2
"6'
-10"
14'-3
"
12'-1
0"19
'-3"
BATH
3-0
RECROOM
SUBFLOOR SYSTEM BY OTHERSWINDOWS & DOORS IN BASEMENT BY OTHERS
MECHANICAL/STORAGE
BASEMENT NOTES:
1) ALL REPRESENTATIONS OF FIXTURES, EQUIPMENT,MATERIALS, ELECTRICAL, PLUMBING, FASTENERS, ETC.ON CLIENTS DESIGN ARE NOT INCLUDED WITH CLIENT'SPACKAGE PURCHASED FROM TENNESSEE LOG &TIMBER HOMES, INC. ONLY ITEMS SPECIFICALLY NOTEDIN TENNESSEE LOG & TIMBER HOMES, INC. PURCHASEAGREEMENT WILL BE INCLUDED IN THE MATERIALS LISTAND SUPPLIED TO THE CLIENT.
2) FOUNDATION MATERIALS SUPPLIED BY OWNER UNLESSSPECIFIED BY CONTRACT.
3) BUILDER TO VERIFY ALL DIMENSIONS ON JOB SITE.
4) IF FOUNDATION WALLS ARE NOT SQUARE OR LEVEL, CORRECTDURING SUBFLOOR CONSTRUCTION.
5) SOLID BLOCKING TO BE USED UNDER ALL POSTS.
6) FIREPLACE DIMENSIONS TO BE VERIFIED BY OWNERBEFORE CONSTRUCTION.
7) BLOCKING TO BE USED UNDER STUD WALLS RUNNINGPARALLEL TO FLOOR JOISTS.
8) BASEMENT WALLS CONSTRUCTED AS PER SITE CONDITIONSAND LOCAL CODES.
9) POSTS DIMENSIONED UNDER GIRDER ARE LOCATED FOR UPPERLEVEL SUPPORTS. ALL OTHER GIRDER SUPPORT POSTS ARELOCATED PER LOCAL CODE ON JOB SITE.
BEDROOMC
LOS
ET
5'-0 3/4" x 6'-11"
HOBBYROOM
3-0
3-0
5-0
3-0
3-0
HV
AC
WORKSHOP
4" CONC. SLAB, 6X6 W.W.M.,6 MIL. POLY. VAPOR BARRIER
AND 4" CRUSHED STONE.
CONC. SLAB
STONE PATIO
STONE PATIO
STONE PATIO
STONE PATIO
GABLEPORCHAREA
ABOVE
WALK-INCLOSET
LOWER LEVEL
RESPONSIBILITY OF THE BUILDER/OWNERTHESE DRAWINGS ARE IN PART DIAGRAMMATIC AND DO NOT SHOW INDETAIL HOW WORKMANSHIP, MATERIALS AND INSTALLATION OF THE MATERIALSINCLUDING THE FIXTURES AND EQUIPMENT ARE TO BE BROUGHT TOGETHERTO COMPLETE THE "WHOLE" STRUCTURE.
IT IS THE RESPONSIBILITY OF THE BUILDER/OWNER TO BUILD THESTRUCTURE TO COMPLY WITH ALL APPLICABLE NATIONAL, STATE,COUNTY AND CITY CODES AS THEY APPLY TO EACH COMPONENT
3-0
6'-0 3/4" x 6'-11"SCDH-60611
5'-0 3/4" x 6'-11"SCDH-50611SCDH-50611
OUTDOORSHOWER
STORAGE/ADDITIONAL
MECHANICAL IFREQUIRED
WA
TER
FILT
ER
ELEC.SERVICE
TAN
KLE
SS
WA
TER
HE
ATE
R
3-0
HALFBATH
FRAMING WITHWRC SHAKES
LOG SIDING ATSUBFLOOR
1X12 & 1X8 WRCSTEPPED FASCIA
PRE-CUTCORNER POST
4X8 DF PRE-CUT TRUSS
PRE-CUT HALFPOST AGAINSTFRAMED WALL
4X8 DF TRUSSMEMBER
6x12 DFPORCH PLATE
10x10 DF PORCH POST
8x8 DFPORCH POST
8x8 DFPORCH POST
DECORATIVESHUTTER
FRONT ELEVATIONNOTE: GRADE CONDITIONS TO
BE VERIFIED ON SITE
1212
1212
1012
312
STEPS TO GRADE PERSITE CONDITIONS
BY OWNER
812
INSTALL FLASHINGBEFORE FINISHED ROOFING
(BY OTHERS)
RAILING BY TLH
LOG SIDINGAT SUBFLOOR
4X8 DF PRE-CUT TRUSS
CANTILEVER BALCONYJOISTS FOR SUPPORT
FRAMING WITHWRC SHAKES
FRAMING WITHWRC SHAKES
FINISHED ROOFING(BY OTHERS)
FRAMING WITHWRC SHAKES
CONTINUOUS RIDGEVENT (BY OTHERS)
PRE-CUT CORNERPOSTS (TYP)
4X8 DF PRE-CUT TRUSS
LEFT ELEVATIONNOTE: GRADE CONDITIONS TO
BE VERIFIED ON SITE
OUTDOOR
SHOWER
1212
4.512
4.512
PRE-CUTDF TRUSS
4X8 DF TRUSSMEMBER
4X10 DF TRUSSMEMBER
10X10 DF POST
4X8 DF TRUSSMEMBER
4X12 DF TRUSSMEMBER
10X10 DF POST
1212
1212
REAR ELEVATIONNOTE: GRADE CONDITIONS TO
BE VERIFIED ON SITE
RAILINGBY OWNER
10X10 DF POST
4.512
NOTE: GRADE CONDITIONS TOBE VERIFIED ON SITE
RIGHT ELEVATION