Purpose of Training
To acquaint you with DOSH’s PPE rules, WAC 296-841 (assessment) and 842 (respirator protection plan), as they apply to school districts.
![Page 3: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/3.jpg)
Topics to Cover
• Washington Administrative Code (WAC)• 296-800-841
– Evaluation and Control of Employee Exposure– When to Require Respiratory Use– Contaminants and Hazard Areas/Jobs– Notify Employees of Hazards and Exposures– Permissible Exposure Limits and Respiratory
Selection• Washington Administrative Code (WAC)• 296-800-842
– Requirements of Required and Voluntary Use Plan
![Page 4: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/4.jpg)
• WAC 296-841 Respiratory Hazards
WAC
![Page 5: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/5.jpg)
Evaluate Exposure
• WAC 296-841 requires the evaluation of work areas that have airborne contaminant exposure.
![Page 6: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/6.jpg)
Areas of Potential Airborne Contaminants
Chemicals in shops; transportation, maintenance, boiler rooms, custodial.
Chemicals used by grounds.
![Page 7: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/7.jpg)
Areas of Potential Airborne Contaminants
Print Shop Chemicals
Particulate from sanding or chemicals from finishing in wood shop
Asbestos in facilities during maintenance.
Particulate and metals from grinding or welding during fabrication
![Page 8: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/8.jpg)
Identification
• Job Hazard Analysis• Check MSDS for listed chemicals• Particulate • Sources without an MSDS
– Existing Building Materials
• Oxygen Deficiency• Biologicals (viruses, mold)
![Page 9: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/9.jpg)
Exposure Assessment Through Estimation
• Reasonably Estimate– Manufacturer’s Information– Observations– Measurements/Calculations– Other Industry Information– Duration of Use
– Ventilation
![Page 10: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/10.jpg)
Exposure Assessment Through Testing
• Use NIOSH approved sampling methods– http://www.cdc.gov/niosh/nmam/
• Ensure appropriate sampling method/media
• Overloading & breakthrough• Sampling limitations
![Page 11: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/11.jpg)
Air Monitoring Continued
• Consider contracting professional industrial hygienist
• Phone book under “Safety Consultants”
![Page 12: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/12.jpg)
Document, Document, Document• Describe the job• List the airborne hazard• Describe the steps of the exposure
assessment • Explain the determination• Include all information used to
make a determination
![Page 13: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/13.jpg)
Control Exposure• WAC 296-841 requires the use of
engineering or administrative controls before using respirators.
• “Feasible Controls” to “below PEL or Lowest Achievable”
• Using Respirators is Costly and Time Consuming!
![Page 14: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/14.jpg)
Administrative Controls
• Chemical Substitution • Change the Process• Separate Employees• Work Practices• Job Rotation
![Page 15: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/15.jpg)
Engineering Controls
• Removing Emissions from the Source– Hoods– Shrouds– Enclosure with negative air/filtration
• Diluting Emissions– Ventilation
• Natural • Forced
![Page 16: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/16.jpg)
Forced Ventilation
![Page 17: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/17.jpg)
Update Job Hazard Analysis
• Appendix D JHA PPE Section • Determination Documentation
– May require supplemental letter outlining exposure assessment process used
• Inform employees
![Page 18: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/18.jpg)
WAC 296-842 Respirators
You have an exposure you cannot control
so you need to provide respirators.
![Page 19: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/19.jpg)
Steps in Implementation
• Designate a Program Administrator• Written Plan• Select Respirators (Steps in WAC
296-842-130)• Medical Evaluations/Fit Testing• Training • Maintenance
![Page 20: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/20.jpg)
Respirator Types
• Dust Mask• Full Face Cartridge• Powered Air Cartridge • Supplied Air • Self Contained Breathing
Apparatus• Escape SCBA
![Page 21: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/21.jpg)
How Filtering Facepieces Work
Air inhaled in Air inhaled in
Air exhaled out
![Page 22: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/22.jpg)
Using Filtering FacepiecesLimits of dust masks
Dust masks will leak if they don’t fit your face properly.
Dust masks don’t filter out chemical vapors.
Dust masks are not adequate for heavy amounts of dust.
Dust masks may not be suitable for highly toxic dusts.
![Page 23: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/23.jpg)
Dust Mask Protection Factor How much protection does a dust
mask give?Dust masks only provide protection to levels 10 times above the chemical or dust permissible exposure limit (PEL).
Example
Wood dust permissible limit – 5 mg/cu. meter
Dust mask protects up to 50 mg/cu. meter
mg/cu. meter = milligrams per cubic meter
![Page 24: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/24.jpg)
NIOSH–Approved Dust Masks
• Dust masks come in variety of styles and brands.
• Not all dust masks provide adequate protection for workplace dust.
• Only NIOSH-approved dust masks can be used for protection against dust levels that exceed the PEL.
Not NIOSH-approved NIOSH-approved
![Page 25: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/25.jpg)
How Respirators Work
Air inhaled in
Air exhaled out
Air inhaled in
![Page 26: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/26.jpg)
How Respirators WorkHow Cartridge Respirators Work
Air movement is controlled by rubber inhalation and exhalation valves.
The adjustable straps are used to keep the respirator snug on the face.
straps
inhalation valves
Facepiece
cartridge
valve cover
exhalation valve
![Page 27: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/27.jpg)
Respirator CartridgesTypes of Cartridges
Dust cartridges filter out dust only.
Chemical cartridges trap different types of chemicals, but not dust.
Cartridges are color-coded for the type of chemical or dust.
![Page 28: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/28.jpg)
Voluntary Respiratory Use
• Must be approved by employer and ensure the following:– Cannot interfere with work, vision, communication– Cannot create health hazards (skin irritation, illness
(sharing respirators), unsafe air supply• Provide advisory information (Table 2)• Develop a written plan• Provide training• Maintain and repair respirators when
necessary• Recordkeeping – medical
![Page 29: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/29.jpg)
Dust Mask Voluntary Use Requirements
• Must be approved by employer• Employer must provide advisory
information (Table 2)• No written plan if only dust mask• No training• No providing respirators, training,
medical or fit testing
![Page 30: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/30.jpg)
Mandatory Respiratory Use • Designate Program Administrator• Develop a Written Plan • Recordkeeping • Medical Evaluation• Fit Testing• Training• Maintenance• Safe Use
![Page 31: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/31.jpg)
Employee Training• When/Where it must be worn• How to put it on and take it off• How to know if it fits• How to inspect • How to keep clean• How to keep maintained• How to store • Limitations
![Page 32: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/32.jpg)
Written Plan
– Designated Program Administrator– Hazard Assessment Certifications– Respirator Selection– Medical Evaluation Provisions– Fit Test Procedures– Training Provisions– Respirator Use Procedures– Maintenance– Procedure for Monitoring Program
Effectiveness
![Page 33: Respiratory Hazard Assessment and Protection Suzanne Reister/Paula Vanderpool North Central ESD 171 509-667-7100/7110](https://reader034.vdocuments.us/reader034/viewer/2022051614/5519ed665503464c588b457a/html5/thumbnails/33.jpg)
Summary• Washington Administrative Code (WAC)• 296-800-841
– Evaluation and Control of Employee Exposure– When to Require Respiratory Use– Contaminants and Hazard Areas/Jobs– Notify Employees of Hazards and Exposures– Permissible Exposure Limits and Respiratory
Selection• Washington Administrative Code (WAC)• 296-800-842
– Requirements of Required and Voluntary Use Plan