residential sjk backdraft damper (gravity)sjk backdraft damper (gravity) rsk backdraft damper...
TRANSCRIPT
68 © FANTECH TRADE 2020
RE
SID
EN
TIA
L R
AN
GE
//
ACCESSORIES
B50
Air Flow
AØ
All dimensions in mm
All dimensions in mm
All dimensions in mm
All dimensions in mm
WALL PLATES
WALL TUBES
WALL RODS
PART NO.
DIMENSIONS TO SUIT FAN SELECTED
AØ B ProVent TD Silent Ezifit In-Wall Ezifit Thru
WallEzifit Thru Roof
SJK150 150 161 RIL-150.. TD-500.. EIE150EWE152 EWE154
ECE152 ECE154
SJK200 200 211 RIL-200.. TD-800.. ECE204
PART NO.
DIMENSIONS TO SUIT FAN SELECTED
AØ B ProVent TD Silent Ezifit In-WallEzifit Thru
WallEzifit Thru Roof
RSK100 100 130 RIL-100 TD-250.. - - -
RSK125 125 130 RIL-125 TD-350.. - - -
RSK150 150 130 RIL-150.. TD-500.. EIE150EWE152 EWE154
ECE152 ECE154
RSK200 200 130 RIL-200.. TD-800.. - - ECE204
RSK250 250 130 TD-1300.. - - -
RSK315 315 130 TD-2000.. - - -
PART NO. HOLE DIAMETER WIDTH HEIGHT
TO SUIT FAN SELECTED
STYLVENT HCM
WP130PK 185 300 320 HV-150AE HCM-150N
WP180PK 219 300 320 HCM-180N
WP225PK 259 425 425 HV-230AE HCM-225N
PART NO.SPIGOT
DIAMETER RANGE
LENGTH
TO SUIT FAN SELECTED
DOM SILENT EDMSILENT DESIGN
RING PLATE
VOGUE STYLVENT HCM
WT130PPK 100 - 130 280DOM-100C DOM-125C
SILENT-100.. SILENT-125..
SILDES100.. SILDES200..
- - - -
WT230PPK 150 - 230 280 DOM-150C SILENT-150..EDM-300C
SILDES300.. RP20.. VCW20.. HV-150AEHCM-150N HCM-180N
WT370PPK 250 - 370 280 - - - -RP25.. RP30.. RP35..
VCW254 VCW30..
HV-230AE HV-300AE
HCM-225N
SJK BACKDRAFT DAMPER (GRAVITY)
RSK BACKDRAFT DAMPER (SPRING LOADED)
Compared to conventional spring loaded backdraft dampers, the SJK has superior performance characteristics due to its unique design that provides minimal resistance to air flow. The flap closes when the fan is off.
The tube is constructed from galvanised steel and the flaps from aluminium. Flaps are spring-loaded and when the fan is switched off they close providing a seal.
Wall Rods are specifically designed for the Stylvent and HCM fans. They are required if the fan is to be installed in walls 25mm - 300mm thick. Comes in packs of 4 wall rods
PART NO.
TO SUIT FAN SELECTED
STYLVENT HCM
WALLRODSPK All ModelsAll
models
SJK150
B
AØ
RSK150
69© FANTECH TRADE 2020
//
CO
MM
ER
CIA
L R
AN
GE
COMMERCIAL
Effective ventilation systems increase productivity and comfort for occupants working in
commercial areas. We can assist by providing energy efficient solutions that reduce heat,
minimise condensation and bring in fresh air to your work space. Our commercial range
includes powerful fans and air movement products suitable for a wide range of applications.
CREATE COMFORTABLE, PRODUCTIVE WORK SPACES.
69
70 © FANTECH TRADE 2020
CO
MM
ER
CIA
L R
AN
GE
//
HAND DRYERS
These ultra powerful units are equipped with digital circuit
controls and advanced infrared auto sensing technologies.
Unit starts when user places hands in a comfortable
position within the unit. The Rapid Dry Jet requires minimal
maintenance and is available with a white or silver coloured
front face.
• Advanced infrared auto sensing technology.
• Hygienic hands free operation for heavy duty
high traffic use.
• Concentrated air flow for rapid drying times.
• Includes excess water tray that can be easily removed
for emptying.
• Easy to clean stylish casing with ergonomic design.
• Water resistant design for a longer lifespan.
• Unique high speed motor for low power consumption.
• Warm or cold air function.
• Plug and lead included as standard.
• Auto-reset internal thermal protection.
• Electrical Test Standard: AS/NZS 60335.1:2011
incl. Amdts. 1-3 AS/NZS 60335.2.23:2012.
White (RAPJET-W) Silver (RAPJET-S)
RAPID DRY JETENERGY SAVINGThe Rapid Dry Jet features a unique high-speed motor that
has a low overall power consumption, concentrated air
flow and a quick drying process. It is programmed to cease
operation after a standard drying time has been reached
to reduce energy consumption.
SAFEThe Rapid Dry Jet smart hand dryer has multiple safety
features that protect the unit against over heating and
electrical surges. The user is kept safe and the hand
dryer is protected. It also
features an excess water
tray that helps to minimise
water landing on the floor.
STRONG The robust, streamline casing protects the technology
within, while being easy to maintain and clean.
HYGIENICIts easy to clean design, non-touch operation and
anti-bacterial filter makes the Rapid Dry Jet perfect for areas
with hygiene requirements.
It also comes with a brush
to clean the water
tray drain hole.
HAND DRYERS
71© FANTECH TRADE 2020
//
CO
MM
ER
CIA
L R
AN
GE
COMPONENTS1. Countdown Indicator
2. Sensor
3. Air Outlet
4. Side Window
5. Power Switch
6. Heat Switch
7. Lighting Screen
8. Front Cover
9. Excess Water Tray
123456
7
8
9
Top View (White Model)
ERGONOMIC & STYLISHDesigned to be aesthetically appealing,
the Rapid Dry Jet will keep your washroom
looking modern. To use the unit, simply
place hands in the drying area and move
them up and down. Hands will be dry
within seconds.
MODEL NO.
FRONT FACE
COLOURM³/HR
AVG. dB(A) @ 3M
IP RATING
VOLTSWEIGHT
KGRATED POWER
A B C
RAPJET-S SILVER 210 78 IP22 240V 8.5 1400W 670 250 300
RAPJET-W WHITE 210 78 IP22 240V 8.5 1400W 670 250 300
All dimensions in mm
SMARTAccurate and reliable air control is a result of a built
in smart microchip and advanced infrared technology.
The hygienic hands free operation automatically starts
when the sensor is triggered. The unit will stop operation
as soon as hands move away. (Maximum drying time:
17 seconds).
HAND DRYERS
72 © FANTECH TRADE 2020
CO
MM
ER
CIA
L R
AN
GE
//
HAND DRYER
RAPID DRY
The Rapid Dry is part of the smart hand dryer range from
Fantech Trade. They are equipped with digital circuit
controls and advanced infrared auto sensing technologies.
These hand dryers require minimal maintenance and include
a robust design that delivers reliable long term performance.
• Advanced infrared auto sensing technology.
• Hygienic hands free operation.
• Concentrated air flow for rapid drying times.
• Casing made from easy to clean 304 stainless steel.
• Water resistant design for a longer lifespan.
• Efficient motor for high performance and low
power consumption.
• Plug and lead included as standard.
• Auto-reset internal thermal protection.
• Warm or cold air function.
ENERGY SAVINGThe Rapid Dry features a unique high-speed motor that
has low overall power consumption. It is fitted with a round
nozzle for concentrated air flow and quick drying time.
It can complete the drying process in half the time of a
regular hand dryer with half the energy consumption.
SAFEThis smart hand dryer has multiple safety features that
protect the unit against over heating and electrical surges.
This extends the lifespan of the unit and keeps the user safe.
STRONGThe streamline shell is made from robust 304 grade
stainless steel. This enclosed casing protects the
technology within and is easy to maintain.
HYGIENICIts easy to clean design,
no-touch operation and
anti-bacterial filter makes
the Rapid Dry perfect
for areas with hygiene
requirements.
HAND DRYERS
73© FANTECH TRADE 2020
//
CO
MM
ER
CIA
L R
AN
GE
Cover
Nozzle
Sensor
Base
Components
All dimensions in mm
MODEL NO. M³/HRAVG
dB(A) @3M
IP RATING
VOLTS FREQUENCYWEIGHT
KGRATED POWER
A B C
RAPDRY-SS 89 80 IP22 240V 50Hz 3.4 900W 169 252 300
SMARTAccurate and reliable air control is a result of a built in smart microchip
and advanced infrared technology. To use, simply bring hands within
10cm of the nozzle and the Rapid Dry will automatically start to blow
warm air. Once your hands are dry, just move them away from the unit
and operation will stop within one second.
BC
A
HAND DRYERS
74 © FANTECH TRADE 2020
CO
MM
ER
CIA
L R
AN
GE
//MODEL NO. STYLE A B C
HHD2500RB Brushed Chrome 270 240 212
HHD2500RW White 270 240 212
MODEL NO. M3/HR L/SECFAN SPEED,
RPM
AVG. dB(A) @1M
WEIGHT KG
HHD2500RB 270 75 8300 74 6.3
HHD2500RW 270 75 8300 74 6.3
All dimensions in mm
HAND DRYERS
A C
B
Brushed Chrome
Available in white or brushed chrome, our automatic hand
dryers provide a cost effective and hygienic means of
no-touch hand drying. Suitable for public amenities,
food prep areas, hospitals and schools.
• Available in white epoxy paint or brushed chrome finish.
• Automatic infrared on/off activation.
• 360° nozzle rotation to provide face or hand drying.
• Drying cycle of approximately 15 seconds.
• Self-resetting thermal overload protection.
• Automatic cut-off after 60 seconds of continuous use.
• 220-240V, single-phase, 50Hz.
MADEMADEMADEMADE
White
Vandal resistant,
robust heavy duty
steel casing. i
HAND DRYERS
75© FANTECH TRADE 2020
//
CO
MM
ER
CIA
L R
AN
GE
All dimensions in mm
AIR VELOCITY & DOOR HEIGHTEffective door height:
• High speed - up to 4.0m
• Low speed - up to 3.0m
High Speed: Suitable
for medium to large
doorways and entrances,
ie. supermarkets and shopping centres.
Low Speed: Suitable for standard doorways;
ie. shops, cafes and small food preparation areas.
AIR CURTAINS
MODEL NO. A B C D E F G
HAC1209WS 900 51 400 113 250 222 212
HAC1212WS 1200 201 400 113 250 222 212
HAC1215WS 1500 351 400 113 250 222 212
6 mounting holes, applicable when 8mm bolts are used (Dim. C)8 mounting holes, applicable when 8mm wood screws are used (Dim. E)
Wall Mounted Switch 5 72.7 4.51.4 3.61.3 2.90.9 2.2
13.5 171 metre
2 metre
3 metre
4 metre
5 metre
Air Outlet
Designed to maximise the efficiency of a building by
creating an invisible door of air that helps to retain a room’s
heating and cooling. It also prevents dust, fumes, odours
and flying insects from entering a building.
• Can reduce a building’s running costs.
• Adjustable air deflection vents.
• High/Low 2-speed operation caters for peak and
off-peak traffic requirements.
• Double-insulated motors with built-in thermal overload
protection.
• 220-240V, single-phase, 50Hz.
• Wall mounted switch included.
• Can be integrated into a Building Management System.
Please note that these Air Curtains are recommended for dry, clean air environments only. For industrial applications or technical data contact your local Fantech Trade branch.
MODEL NO. VOLTAGE/HZ SPEED CURRENT A EFFECTIVE DOOR HEIGHT M VEL M/SEC FAN SPEED, RPMAVG. dB(A)
@ 3MWATTS
HAC1209WS 240/50
High 0.8 4.0 17 2100 61 200
Low 0.75 3.0 13.5 1610 58 185
HAC1212WS 240/50
High 1.0 4.0 17 2100 61 240
Low 0.95 3.0 13.5 1610 58 220
HAC1215WS 240/50
High 1.3 4.0 17 2100 61 320
Low 1.25 3.0 13.5 1610 58 300
SINGLE PHASE
AIR CURTAINS
76 © FANTECH TRADE 2020
CO
MM
ER
CIA
L R
AN
GE
//
WALL & CEILING MOUNTED FANS
Contact your local Fantech branch for more information.
SQUARE PLATE AXIAL SERIES
Air Flow
MODEL NO. CP..
NOM. SPEED REV/SEC
AIR FLOW
M³/SEC†
AVG. dB(A) @3M
CPE.. 1 PH CPD..3 PH. MAX. AMB
°CKW AMPS* KW AMPS*
0254F 23 0.27 42 0.09 0.90 0.12 0.50 70^
0314F 23 0.62 45 0.09 0.90 0.12 0.50 70^
0314FHP 23 0.56 49 0.09 0.90 0.12 0.50 70^
0354F 23 0.93 49 0.09 0.90 0.12 0.50 70^
0354FHP 23 0.72 52 0.09 0.90 0.12 0.50 70^
0404F 23 1.42 52 0.25 1.80 0.37 1.40 70^
0404FHP 23 1.21 54 0.25 1.80 0.37 1.40 70^
0454F 23 1.65 54 0.25 1.80 0.37 1.40 70^
0454FHP 23 1.59 57 0.25 1.80 0.37 1.40 70^
* Amperages shown are a guide only, refer to our Sales Department for accurate figures at time of order. (Electrical data in bold type refers to fans that are fitted with 2-speed star/delta motors as standard).
High speed data shown. ^ Maximum ambient is 40°C when being speed controlled.
HP - High Performance model.† Air flow without duct and fittings.
The Compact 2000 Series is a high quality and robust
axial fan range that is suitable for a wide range of
commercial and industrial applications. It can be speed
controlled to better manage energy consumption.
• Single phase models only can be speed controlled.
• Robust galvanised steel construction.
• Inlet guard is incorporated as standard.
• Capable of operating across a wide temperature range.
• To make installation easy, a flying lead with junction box
and 20mm Ø flexible conduit is fitted.
• Finished in durable polyester epoxy paint.
• Can be mounted in any position.
MODEL NO. AØ BØ C D E F G HØWEIGHT
KG
CPD0254F, CPE0254F
263 285 370 320 98 74 15 6 5.5
CPD0314F, CPE0314F
325 330 430 380 95 85 10 9 10
CPD0354F, CPE0354F
360 370 485 435 95 85 10 9 10
CPD0404F, CPE0404F
410 420 540 490 95 95 12 9 15
CPD0454F, CPE0454F
460 470 575 535 95 95 12 11 17
‘CPD’ denotes three phase models ‘CPE’ denotes single phase modelsAll dimensions in mm
COMPACT 2000
IPIP5555
Contact your local Fantech branch for more information.
454H
P
504H
P
404H
P
4 Pole24 rev/secHP
564H
P
dB(A) @ 3m: Outlet Side =
0.2 0.4 0.6 1.0 2.0 4.0
qV - Volume Flow, m /s3
p SF
- Fan
Sta
ticP
ress
ure,
P a
40
60
100
200
20
10
400
Syst
emLi
nes
314H
P354
HP
49 52 57 62 6354
454H
P
504H
P
404H
P
4 Pole24 rev/secHP
564H
P
dB(A) @ 3m: Outlet Side =
0.2 0.4 0.6 1.0 2.0 4.0
qV - Volume Flow, m /s3
p SF
- Fan
Sta
ticP
ress
ure,
P a
40
60
100
200
20
10
400
Syst
emLi
nes
314H
P354
HP
49 52 57 62 6354
4.0 6.0 10.0 20.0
4 Pole24 rev/sec
dB(A) @ 3m: Outlet Side =
0.60.2 0.4 2.01.0
qV - Volume Flow, m /s3
p SF
- Fan
Sta
ticP
ress
ure,
P a
40
60
100
200
20
10
400
314254
354
404454
Syst
emLi
nes
42 45 49 52 54
ACCESSORIES• Electronic Speed Controller
(VA5.0 - for single phase only).
• Rear Finger Guards (DG..).
• Backdraft Shutter (WSK..).
77© FANTECH TRADE 2020
//
CO
MM
ER
CIA
L R
AN
GE
WALL & CEILING MOUNTED FANS
MODEL NO. DUCT SIZE AØ B C D EØ FØ
RP202/204 200 280 250 5 95 208 215
RP252/254 250 320 295 7 103 259 266
RP302/304/306 300 395 375 7 113 310 318
RP354/356 350 460 422 7 123 360 375
All dimensions in mm
FØ
AØ DC
EØ
4 x 6 Holeson B P.C.D.
Ø
Air Flow
MODEL NO.
AIR FLOW
M³/HR†
AIR FLOW
L/SEC†
FAN SPEED REV/SEC
AVG. dB(A) @ 3M
RP.. 1 PH MAX. °C
WATTS AMPS*
RP202 792 220 43 52 70 0.36 50
RP204 468 130 24 39 30 0.14 60
RP252 1620 450 42 51 110 0.63 50
RP254 1008 280 23 40 60 0.28 60
RP302 2376 660 41 62 180 0.79 50
RP304 1728 480 22 47 90 0.41 50
RP306 1296 360 16 37 50 0.23 50
RP354 2628 730 20 49 140 0.68 50
RP356 2340 650 16 40 110 0.48 50
† Air flow without duct and fittings * Amperages shown are a guide only. Refer to our Sales Department for accurate figures at time of order.
RING PLATEWALL & CEILING MOUNTED FANS
The Ring Plate Axial Fans are suitable for wall or ceiling mounting and feature a high quality galvanised steel casing, grille and impeller. Their robust construction makes them suitable for a broad range of commercial and industrial applications.
• Powerful air flow and pressure performance. • High quality Continuous Run motor. • Can be connected to ducting. • Speed-controllable. • Auto-reset thermal cut out protection fitted. • Sealed for life ball bearings.• 220-240V, Single-phase, 50Hz.
IPIP4444
qV - Volume Flow, m /s3
p SF
-Fan
Sta
ticP
ress
ure,
P a
0.1 0.2 0.4 0.60.0610
40
60
100
200
= Avg. dB(A) @ 3m
20
202
Syst
emLin
es
252
2 Pole44 rev/sec
302
62
49
50
5253
56
5158
qV - Volume Flow, m /s3
p SF
-Fan
Sta
ticP
ress
ure,
Pa
0.4 0.60.20.10.0610
100
80
60
40
= Avg. dB(A) @ 3m
20
306
38
6 Pole15 rev/sec
37
Syst
emLi
nes
39
40
356
qV - Volume Flow, m /s3
p SF
-Fan
Sta
ticP
ress
ure,
Pa
0.04 0.10.06 0.2 0.4 0.610
100
60
40
20
= Avg. dB(A) @ 3m
4 Pole23 rev/sec150
204
254
39
Syst
emLi
nes
44
47
304
48
49
50
354
41
40
ACCESSORIES• Run-on Timers & Speed Controllers.
• Flexible Duct - Fire Rated AS/NZS 4254.
• Wall Tubes.
• External Grilles.
78 © FANTECH TRADE 2020
CO
MM
ER
CIA
L R
AN
GE
//
WALL & CEILING MOUNTED FANS
MODEL NO. A B C DØ EØ FØ
VCW202 , VCW204 295 268 100 197 208 255
VCW254 347 320 110 247 259 305
VCW302 , VCW304, VCW306 398 371 115 297 310 355
All dimensions in mm
A
4 x 5 Holeson B P.C.D.
Ø
22 C
FØcutoutEØ
OptionalDuct Adapter
DØ
5020 Air Flow
MODEL NO. VCW..
M³/HR†
L/SEC†
FAN SPEED REV/SEC
AVG. dB(A) @ 3M
VCW.. 1 PH MAX. °CWATTS AMPS*
202 792 220 43 52 70 0.36 50
204 468 130 24 39 30 0.14 60
254 1008 280 23 40 60 0.28 60
302 2376 660 41 62 180 0.79 50
304 1728 480 22 47 90 0.41 50
306 1296 359 16 37 50 0.23 50
† Air flow without duct and fittings * Amperages shown are a guide only.
Refer to our Sales Department for accurate figures at time of order.The Vogue series of modern ceiling/wall mounted fans include quick fitting swing locks that make it easy to install in suspended ceilings or plasterboard walls and ceilings. The grille is made from durable ABS plastic and impellers are of galvanised steel.
• Contemporary flush to ceiling design. • Grille can be easily removed for cleaning. • Speed-controllable.• Fitted with a standard 240V plug and lead. • Auto-reset thermal cut out protection fitted. • Sealed for life ball bearings. • High quality, 220-240V, single-phase, 50Hz ‘Continuous
Run’ motor.• Model with reverse air flow available.
OPTIONAL DUCT ADAPTERThe optional Vogue duct adapter allows standard sized duct to be easily fitted to the fan. It simply slides onto the fans’ spigot and is secured with duct tape. Made from durable ABS plastic.
MODEL NO.DUCT
DIAMETERVOGUE (TO SUIT FAN
SELECTED)
VCW20DA 200 VCW202, VCW204
VCW25DA 250 VCW254
VCW30DA 300 VCW302 , VCW304, VCW306
VOGUEWALL & CEILINGMOUNTED FANS
IPIP4444
ACCESSORIES• Run-on Timers & Speed Controllers. • Flexible Duct - Fire Rated AS/NZS 4254 • Wall Tubes• External Grilles.
79© FANTECH TRADE 2020
//
CO
MM
ER
CIA
L R
AN
GE
IN-LINE DUCT MOUNTED FANS
VENTMAJORIN-LINE DUCT MOUNTED FANS
MODEL NO. A B CØ DØ E
VM-100L 195 23 243 98 154
VM-125L 197 27 243 123 154
VM-150L 213 22 333 147 201
VM-200L 223 25 333 198 201
VM-250L 205 27 333 248 201
VM-315L 232 25 401 312 237
All dimensions in mm
Mounting Foot(included)B B
DØ CØ
A
170crs
255
E
MODEL NO. VM-...
M³/HR L/SEC
FAN SPEED REV/SEC
AVG. dB(A) @
3M
VM.. 1 PH.MAX.
OCWATTS AMPS
100L 277 77 42 47 75 0.33 60
125L 410 114 41 47 80 0.35 60
150L 700 194 45 50 120 0.53 60
200L 1000 278 43 52 170 0.72 60
250L 1100 306 46 54 180 0.80 60
315L 1630 453 45 57 315 1.30 50
The VentMajor Series of duct-mounted, all metal
centrifugal fans is suitable for exhaust or supply air
applications. These robust high performance fans can
be used for a wide range of residential, commercial
and industrial needs. There are 6 models in the range,
matching standard duct sizes from 100 to 315mm
diameter.
• High performance impellers of backward-curved
centrifugal design ensuring a stall free operation.
• Robust galvanised steel construction.
• Designed for direct connection to standard diameter
circular ducting.
• Suitable for both supply and exhaust air applications.
• Electrical junction box fitted to simplify installation.
• Mounting foot supplied as standard.
ACCESSORIES• Speed Controllers.
• Flexible Duct - Fire Rated AS/NZS 4254.
• Backdraft Dampers.
• Internal & External Grilles.
IPIP4444
*Amperages shown are a guide only. Refer to our Sales Department for accurate figures at time of order.
Manufactured from high
quality corrosion resistant
galvanised steel. i
80 © FANTECH TRADE 2020
CO
MM
ER
CIA
L R
AN
GE
//
IN-LINE DUCT MOUNTED FANS
MODEL NO. AØ B CWEIGHT
KG
MTP202, MTP204 197 250 270 2.1
MTS202, MTS204 206 250 236 3.5
MTP252, MTP254 247 250 320 2.7
MTS252, MTS254 260 250 296 4.0
MTP302, MTP304, MTP306 297 250 370 3.5
MTS302, MTS304, MTS306 311 250 346 4.8
MTS354, MTS356 363 250 405 5.1
MINITUBE
B
AØC
Metal construction model (MTS)
MODEL NO. MT...FAN
SPEED REV/SEC
AVG. dB(A) @ 3M
MTP/S.. 1 PH.MAX. OC
WATTS AMPS*
P/S202 43 52 70 0.36 50
P/S204 24 39 30 0.14 60
P/S252 42 51 110 0.63 50
P/S254 23 40 60 0.28 60
P/S302 41 62 180 0.79 50
P/S304 22 47 90 0.41 50
P/S306 16 37 50 0.23 50
S354 20 49 140 0.68 50
S356 16 40 110 0.48 50
* Amperages shown are a guide only. Refer to our Sales Department for accurate figures at time of order.
Plastic construction model (MTP)
The Minitube Series of duct mounted axial fans is suitable
for domestic, commercial and industrial ventilation
applications. Available in sizes ranging from 200 to
350mm diameter.
• Choice of two light-weight but robust housing materials,
metal or injection moulded plastic.
• Good range of speeds available.
• Can be speed controlled.
• Can be mounted in any position.
• All models feature high strength powder coated
steel impellers.
• Manual reset protection fitted at standard.
• 3 pin plug and lead fitted in the plastic model.
IN-LINE DUCT MOUNTED FANS
IPIP4444‘MTP’ denotes ABS injection moulded plastic casing
‘MTS’ denotes powered coated steel casing All dimensions in mm
A light-weight yet robust in-line fan available with either plastic or steel casing.
iACCESSORIES• VA2.0 Speed Controller.
• Flexible Duct - Fire Rated AS/NZS 4254.
• Backdraft Dampers.
• Internal & External Grilles.
qV - Volume Flow, m /s3
p SF
- Fan
Sta
ticP
ress
ure,
Pa
0.03 0.1 0.2 0.4 0.60.0620
40
60
100
200
Syst
emLi
nes
= Avg. dB(A) @ 3m
2 Pole44 rev/sec
202
252
302
62
59
58
54
52
51
49
53
52
51
50
qV - Volume Flow, m /s3
p SF
-Fan
Sta
ticP
ress
ure,
Pa
0.4 0.60.20.10.060.0420
100
80
60
40
6 Pole15 rev/sec
306
Syst
emLi
nes
356
= Avg. dB(A) @ 3m
39
37
40
39
qV - Volume Flow, m /s3
p SF
- Fan
Sta
ticP
ress
ure,
Pa
0.03 0.1 0.2 0.4 0.60.0620
40
60
100
200
Syst
emLi
nes
= Avg. dB(A) @ 3m
204
254
304
354
39
40
41 47
46
44
49
50
4 Pole23 rev/sec
81© FANTECH TRADE 2020
//
CO
MM
ER
CIA
L R
AN
GE
IN-LINE DUCT MOUNTED FANS
SHORT CASE
The Short Case Axial Series has a light-weight, but robust
construction and is designed for exhaust and supply air
ducted systems in commercial and industrial applications.
• Compact, short cased design.
• Light-weight but robust construction.
• An electrical junction box is fitted as standard.
• Capable of operating in ambient temperatures ranging
from -20°C to +70°C.
• Can be mounted in any position.
• Available in single and three phase:
- 230V, Single phase, 50Hz.
- 415V, Three phase, 50Hz.
ACCESSORIES• Mounting Feet (CFT..).
• Inlet Cones (CIC..S).
• Matching Flanges (CMF..).
• Finger Guards (DG..).
• Electronic Speed Controller
- VA2.8 (for single phase only).
IPIP5555
IN-LINE DUCT MOUNTED FANS
qV - Volume Flow, m /s3
0.6 4.02.01.0 6.0
354
404454
dB(A) @ 3m: Outlet Side =
47 50
8.0
4 Pole24 rev/sec
p SF
- Fan
Sta
ticP
ress
ure,
Pa
100
20
10
40
60
300
200
0.2 0.4
Syst
emLin
es
254
39 42 45314
IN-LINE DUCT MOUNTED FANS
. .
MODEL NO. AØ BØ* C D EØ FWEIGHT
KG
SCD254, SCE254 305 250 180 8 7 285 8
SCD314, SCE314 382 315 180 8 9.5 356 8.5
SCD354, SCE354 421 350 180 8 9.5 395 9
SCD404, SCE404 466 400 190 12 9.5 438 12
SCD454, SCE454 515 450 190 12 9.5 487 14
MODEL NO. SCD.. SCE..
FAN SPEED REV/SEC
M³/HR
L/SEC
AVG. dB(A) @ 3M
SCE.. 1 PH. SCD.. 3 PH.
KW AMPS KW AMPS
254 23 983 273 39 0.09 0.90 0.12 0.50
314 23 2099 583 42 0.09 0.90 0.12 0.50
314HP 23 1958 544 49 0.09 0.90 0.12 0.50
354 23 2686 746 45 0.09 0.90 0.12 0.50
354HP 23 2513 698 52 0.09 0.90 0.12 0.50
404 23 4777 1327 47 0.25 1.80 0.37 1.40
404HP 23 4324 1201 54 0.25 1.80 0.37 1.40
454 23 5789 1608 50 0.25 1.80 0.37 1.40
454HP 23 5695 1582 57 0.25 1.80 0.37 1.40
Electrical data in bold type denotes 2-speed star/delta motors are fitted. Amperages shown are a guide only. Refer to our Sales Department for accurate figures at time of order.
* Dimension BØ is internal for the casing ‘SCD’ denotes three phase, ‘SCE’ denotes single phase.
All dimensions in mm
When being speed controlled the ambient must not exceed 50°C.
Contact your local Fantech branch for more information.
82 © FANTECH TRADE 2020
CO
MM
ER
CIA
L R
AN
GE
//
200.10 0.300.20 0.60 1 2 3
40
80
120
Sta
tic P
ress
ure
(Pa)
160200
400
600
...464
...386
...304L
...254...306
...384
...466
...304
KU...
Systemaire commercial kitchen exhaust fans provide
powerful performance, energy efficiency and quiet
operation. They have been designed and tested by our own
Fantech engineering team and have proven to be up
to 9dB(A) quieter, and produce up to 35% more air flow than
other equivalent kitchen exhaust fans.
These high performance kitchen exhaust fans are available
in 250, 300, 380 and 460mm fan inlet sizes.
• Can produce up to 88% more pressure and be up to 9dB(A) quieter than equivalent kitchen exhaust fans currently on the market.
• Greater number of drainage holes included around base to prevent water build-up.
• Lightweight design for easier handling and installation.• Supplied with matching flange for quick installation to suit
standard round Spiro duct.• Can be used with smaller duct sizes as the fan can handle
high pressure levels.• Designed to handle clean air, grease laden air, toxic
and noxious gases.
• Advanced mixed flow impeller design provides high air
flow performance with low noise levels.• Designed for small to medium sized commercial kitchens
in restaurants, cafés and take away food outlets.
KITCHEN EXHAUST FANS
SYSTEMAIRE
ROOF MOUNTED FANS
IPIP5555
D
C
B
25 AØ
Ø
Matching flange supplied
to fit to round ductwork
MODEL NO. A B C DAPPROX.
WEIGHT KG*
KU_25 260 443 53 580 14
KU_30.L 312 443 53 580 14
KU_30 312 554 16 730 22
KU_38 384 554 39 730 27
KU_46 464 554 64 730 30
Dimensions in mm* Unit weights depend on the make of motor used. If critical this should be referred to our
sales department at time of order.
83© FANTECH TRADE 2020
//
CO
MM
ER
CIA
L R
AN
GE
ROOF MOUNTED FANS
COMPONENTS
Aerodynamic shaped cowl for smoother air flow, reduced
turbulence and increased fan performance.
Weather and contaminant proof enclosure for maximum
motor protection.
Smaller exhaust opening than traditional kitchen exhausts
fans reduces exposure to rain.
Removable wind band for easy cleaning and maintenance.
High performance mixed flow impeller provides quieter
operation with better air flow and higher pressure development.
Greater number of drainage holes included around base to
prevent water build up.
1
2
3
4
5
6
1
2
34
5
MODEL NO.FAN SPEED
REV/SECL/SEC* M3/HR* Phase KW AMPS
AVG. dB(A) @3M
INLET SOUNDOUTLET SOUND
KUD254 24 480 1728 Three 0.25 0.75 44 48
KUE254 24 480 1728 Single 0.18 1.4 47 51
KUD304L 24 700 2520 Three 0.25 0.75 46 50
KUE304L 24 700 2520 Single 0.18 1.4 45 49
KUD304 24 800 2880 Three 0.25 0.75 44 48
KUD306 16 500 1800 Three 0.25 1.32 34 38
KUE304 24 800 2880 Single 0.18 1.4 45 50
KUE306 16 500 1800 Single 0.25 2.5 36 40
KUD384 24 1640 5940 Three 0.75 1.94 51 56
KUD386 16 1000 3600 Three 0.37 1.32 41 45
KUE384 24 1640 5940 Single 0.75 4.8 50 54
KUE386 16 1000 3600 Single 0.37 2.5 40 44
KUD464 24 2250 8100 Three 1.1 2.57 54 60
KUD466 16 1330 4788 Three 0.37 1.32 42 48
KUE464 24 2250 8100 Single 1.1 6.6 53 59
KUE466 16 1330 4788 Single 0.37 2.5 43 49
6
* Air flows are approximate only and based on 30 Pa static pressure.
84 © FANTECH TRADE 2020
CO
MM
ER
CIA
L R
AN
GE
//
FEATURES
• User friendly interface with start-up wizard for quick and easy configuration.• Integrated PI controller for smooth variable speed control. • EMC filters to remove electromagnetic interference and lower harmonic levels. • Fire mode function with quick start wizard. • Available as IP54 rated.
VARIABLE SPEED DRIVES DANFOSS VLT - HVAC BASIC
DANFOSS VLT - MICRO
WALL PLATE SPEED CONTROLLERS
The VLT - HVAC Basic is a dedicated drive that is easy to install, and features
a trouble-free set up which ensures it is fast and efficient to commission.
It incorporates a highly effective heat management system that makes it ideal
for demanding environments and where drive space is restricted.
The VLT - Micro drive has been designed for applications where simplicity and
efficiency are key requirements. The compact size of the enclosure with forced
cooled heat sink allows the drive to be installed into confined spaces.
FEATURES• Interface with start-up wizard for quick and easy configuration. • EMC filters to remove electromagnetic interference and lower harmonic levels. • Available as IP20 (with optional IP21 kit). • Optional 1ph input to 3 phase output (0.18 - 2.2kW).
2-speed rotary switch (TSS1-15).
Use with VSD, 415V, 3PH units
0-10V speed controller (DCV-POT10K-WM)
Use with VSD,415V, 3PH units
Variable speed controller(VA2.0, VA5.0, VA8.0 for 240V, 1PH, 4 pole units)
ROOF MOUNTED FANS
85© FANTECH TRADE 2020
//
CO
MM
ER
CIA
L R
AN
GE
ROOF MOUNTED FANS
MODEL NO. A B C D E WEIGHT
KG
MV112E210 260 30 200 310
1.3
MV132E 1.9
MV202E
350 410 55 350 570
4.6
MV204E 4.5
MV252E 5.9
MV254E 6.1
MV302E
350 410 55 350 570
6.9
MV304E 6.5
MV306E 6.5
MV354E400 500 95 380 670
8.5
MV356E 8.5
All dimensions in mm
ROOF MOUNTED FANS
MODEL NO. MV...M³/HR
L/SEC
FAN SPEED REV/SEC
AVG. dB(A) @ 3M
SINGLE PHASEMAX.
OCWATTS AMPS*
112 122 34 44 33 22 0.11 50
132 270 75 46 43 46 0.25 50
202 688 191 43 52 70 0.36 50
204 299 83 24 38 30 0.14 60
252 1274 354 42 51 110 0.63 50
254 785 218 23 42 60 0.18 60
302 2066 574 41 55 180 0.79 50
304 1303 362 22 44 90 0.41 50
306 882 245 16 39 50 0.23 50
354 1901 528 20 50 140 0.68 50
356 1472 409 16 45 110 0.48 50
*Amperages shown are a guide only. Refer to our Sales Department for accurate figures at time of order.
MINIVENT
The Minivent Series of axial roof units has been designed
for use in a wide range of free intake or duct mounted,
domestic and commercial applications. They can be speed
controlled and are available in 6 sizes ranging from 112 to
350mm diameter.
• Robust, lightweight construction.
• Wide choice of speeds for most sizes.
• All motors are speed controllable.
• Can be used in ducted systems.
• Can be mounted at angles up to 30°.
• Backdraft shutters can be fitted to fans 250 to
350mm diameter.
• Single phase, 240V only.
IPIP4444
ACCESSORIES• Run-on Timers & Speed Controllers.• Flexible Duct - Fire Rated AS/NZS 4254.• A range of upstands are available. For information on
suitable upstands contact your local Fantech Trade branch.
qV - Volume Flow, m /s3
p SF
-Fa
nS
tatic
Pre
ssur
e,Pa
0.02 0.04 0.1 0.2 0.4 0.60.0620
40
60
100
200
250
Sys
tem
Line
s
MV132E
MV202E
MV252E
MV302E
2 Pole44 rev/sec
MV112E
= A vg. dB(A) @ 3 m
33
42
52
49
49
5055
51
5355
43
qV - Volume Flow, m /s3
p SF
-Fa
nS
tatic
Pre
ssur
e,Pa
0.40.20.10.060.0420
100
150
80
60
40
MV306E M
V356ESyst
emLi
nes
6 Pole15 rev/sec
= A vg. dB(A) @ 3 m
4438
3945
qV - Volume Flow, m /s3
p SF
-Fa
nS
tatic
Pre
ssur
e,Pa
0.040.020.01 0.10.06 0.2 0.4 0.620
200
100
60
40
MV254E
MV304E
MV354E
MV204E
Syst
emLi
nes
4 Pole23 rev/sec
= A vg. dB(A) @ 3 m
5141
38
4244 50
40
44
86 © FANTECH TRADE 2020
CO
MM
ER
CIA
L R
AN
GE
//MODEL NO.
M³/HR L/SECNOM.
SPEED R/S
AVG. dB(A) @ 3M (INLET)
CE..1 PH.*
LOWAIR
FLOW
HIGHAIR
FLOWKW AMPS
CE192V 443 123 42 45 47 0.07 0.30
CE224V 594 165 23 38 39 0.05 0.26
CE252V 972 270 42 56 58 0.19 0.83
CE254V 893 248 23 41 42 0.08 0.37
CE284V 1080 300 23 44 45 0.09 0.40
CE314V 1314 365 23 47 48 0.15 0.66
CE354V 2311 642 23 52 51 0.28 1.25
CE404V 3460 961 23 56 54 0.49 2.20
MODEL NO. A B C DØ EWEIGHT
KG
CE192V
CE224V
CE252V
CE254V
260 310 50 430 244 4
CE284V
310 410 75 500 334 8
CE314V
CE354V
400 500 75 640 417 18
CE404V
VERTICAL DISCHARGE
All dimensions in mm
*Amperages shown are a guide only, refer to our Sales Department for accurate figures at time of order.
The Gamma Series of centrifugal roof units
has been designed for use in commercial ducted exhaust
applications. Models CE284V and larger are fitted with
bird mesh to prevent the entry of birds and vermin into the
ducting or building..
• Robust, lightweight construction.
• Cowls are U.V. stabilised.
• Compact, low profile design.
• Can be used in ducted systems.
• Can be mounted at angles up to 30°.
• Single phase, 240V only.
ACCESSORIES• Run-on Timers & Speed Controllers.
• A range of upstands are available. For information on
suitable upstands contact your local Fantech Trade branch.
GAMMA
IPIP4444
ROOF MOUNTED FANS
qV - Volume Flow, m /s3
p SF
- Fan
Sta
ticP
ress
ure,
Pa
0.1 0.2 0.4 0.6 1.00.063040
60
100
200
600
400
2 & 4 Pole42 & 23 r/s
354V
404V252V
254V
284V
224V
192V
314V
Syst
emLi
nes
-1
47 39
58
-2
42 45
-1-1
-2
-1
4851
54
+1+2
dB(A) @ 3m: Inlet Side =
87© FANTECH TRADE 2020
//
CO
MM
ER
CIA
L R
AN
GE
RELIEF AIR VENTS
ALPHA
All dimensions in mm
MODEL NO. A B C D E APP.
WEIGHTKG
APP. VOL.M3
MIN.FREE
AREA M2
MRV1 210 260 30 200 310 1.0 0.02 0.017
MRV2 350 410 55 350 570 3.0 0.14 0.073
The Alpha Relief Air Vents have been designed to control
air pressure within buildings. They may also be used in a
ducted system where the fan is mounted remotely to the
cowl. Fitted with bird mesh to eliminate the risk of debris
and birds entering the building.
• Lightweight, corrosion-proof construction.
• Can also be used as air intake units.
• Protective bird mesh guards are fitted as standard.
• Base and cowl made of U.V. stabilised plastic.
• Designed for curb mounting.
• Can be mounted at angles up to 30°.
TYPICAL APPLICATIONExhausting clean air and a range of toxic, noxious and
corrosive gases from a wide range of commercial and
industrial applications.
ACCESSORIES • A range of upstands are available. For information on
suitable upstands contact your local Fantech Trade branch.
ROOF MOUNTED FANS
May be used as the air
intake and discharge
point where the fan is
mounted remotely.i
qV - Volume Flow, m /s3
p- P
ress
ure
Loss
, Pa
0.06 0.1 0.4 0.6 1.0 2.0 4.0 6.00.2
20
10
30
40
60
100ReliefVents
MR
V1
MR
V2