FOR YOUR INFORMATIONFREQUENTLY ASKED QUESTIONS
Where-can the building be placed on the property?
A building must be placed in accordance with Zone specific setbacks laid out in Zoning By-Law 190-10.
What is the minimum size building I can place on my property?
a) No single-unit dwelling may be placed, erected or altered so that it has an overall width and ground floor area of less than:
i) In the case of a single storey dwelling, 7.3 meters (24 ft) in width and 89.2 square meters (960 square feet) in area; and
ii) In the case of a one and one-half storey or a two storey dwelling, 7.3 meters or 24' wide and 71 square meters or 764 square feet in area .
(b) No two-unit dwelling may be placed, erected or altered so that it contains a dwelling unit with a ground floor area less than:
i. If one unit is above the other, 7.3 meters or 24 ft in width and 89.2 square meters or 960 square feet in area, or
ii. If semi-detached;1. 960 square feet, in the case of a one-story dwelling; and
2. 485 square feet, in the case of a two-storey dwelling.
Is there a limit to the number of Buildings permitted on my property?
A maximum of one. dwelling unit per lot is permitted.
How much will my permit cost?
The permit fee to construct a building is based on $5.00 per $1,000.00 of the estimated value* of your project.
*Estimated Value of project will be calculated in office if contractors estimate is not provided with application.
Is there anything else I need to be concerned with when planning a building project?
It is advised that land owners check their properties for restrictive covenants before beginning a project. While the Town does not enforce these covenants it is in the land owner's best interest to be aware of them.
FOR YOUR INFORMATION
Also, depending on the type of project; location, services provided there may be other permits or approvals required. Plumbing Permits & Electrical Permits (licensed tradesmen are responsible to obtain the necessary provincial permits) New Brunswick Department of Public Safety- Technical Inspection Services Saint John Telephone: (506) 658-2510 Email: [email protected] Septic System Approval* New Brunswick Department of Health - Public Health On-Site Sewage Disposal Telephone: (506) 658-3022 Email: [email protected] Wetland & Watercourse Alteration Permit* New Brunswick Department of Environment & Local Government - Saint John Regional Office Telephone: (506) 658-2558 Email: elg/[email protected] New Brunswick Fire Marshall (required for large scale projects) * New Brunswick Department of Public Safety- Office of the Fire Marshall Telephone: (506) 453-2004 Email: [email protected] *Building Permit will not be issued until a copy of Approval/ Permit is submitted to the Planning & Development Department
FOR YOUR INFORMATION: RESIDENTIAL INSPECTIONS
1st – Pre=pour Footings 2nd – Footings and Foundation Walls 3rd – Drainage Tile Backfill 4th – Sewer Connection 5th – Pre-pour Floor 6th – Structural 7th – Insulation and Poly 8th- Pre-Cladding 9th – Final NOTE: It is the responsibility of the Homeowner / Contractor to call for All Inspections with a minimum notice of 72 hours.
TOWN OF HAMPTON Zoning By law 190-10
3.4 Development / Building Permit
a) No person shall undertake a development as defined by the community Planning Act of
New Brunswick, without having obtained a Development and Building Permit.
b) No Development or Building Permit shall be issued unless the proposed development
conforms to all provisions of this By-law, and all other By-laws of the Town of Hampton;
c) Any Development or Building Permit shall be in force for a period of one (1) year from
the date of issue or until the project has been completed or is discontinued for a period
of 6 (six) months and any permit may be reissued upon request, subject to review by
the Town of Hampton Development Officer or Building Inspector;
d) No Development or Building Permit may be issued under this By-law except where the
applicant has paid a fee as established by Council;
e) A development permit is required for any alteration to the interior of a building or
structure involving the following:
i. A change of use (including changing from one permitted use to another
permitted use within the same zone);
ii. An increase in the number of dwelling units;
iii. A structural alteration;
iv. Any alteration to the exterior of a building or structure which involves an
increase in the size or exterior dimensions;
v. Commencement of a home occupation; and
vi. Development (including driveway paving) on Town-owned land.
✓ Designers Name and Contact info
✓ Text and dimensions must be legible
✓ No mirrored plans
✓ Modifications to plans must be clear and legible (no sketching of changes. Hand drafting is
acceptable)
✓ Minimum scale 3/16" =1' -0" for single and two-family dwellings
✓ Cross sectionals for Foundation walls and Exterior Walls
✓ Energy cross-sections include R values
✓ Flashing Details for window. Doors, ledgers.
✓ Strip Footing, Foundation Wall Dimensions and Anchoring
✓ Diagonal Bracing for the roof system
✓ Radon rough-in
✓ Location of smoke and carbon monoxide alarms must be shown on the plans
✓ Self-closing for doors for garage
✓ Header and Lintel information
✓ All pads for load-bearing walls etc.
✓ Column Loading
✓ A North Arrow or indicate on street frontage
✓ Not for Construction Drawings, drawings will be rejected
✓ Designer to identify all tall walls (These will need to be Engineered)
✓ Decks must be detailed on plans
✓ Elevations must match anticipated site conditions within reason
✓ Plans cannot contain any obvious code violations
✓ The insulation location and details must match site installation
✓ Drawing must show what is being constructed.
FOR YOUR INFORMATIONMUST BE INCLUDED IN APPLICATION
TO BE SUBMITTED
RESIDENTIAL BUILDING APPLICATION Do not write in shaded areas
Date of Application: Permit Fee:
Fee: Paid: Inv. No.:
Permit application must be completed in FULL before being processed
GENERAL INFORMATION
Property Owner’s Name:
Email:
Home Phone #: Cell:
Mailing Address:
Contractor Contact Name:
Contractor Phone #:
PROPERTY INFORMATION
P.l.D. #: P.A.N. #:
Location of Project:
Variance: N/A Granted Pending Denied
Zoning:
DEVELOPMENT APPROVAL
Intended Use:
Permitted Use: Yes No Development Officer:
Reason:
Construction / Development Information __________________________________________________________________________
Type of Activity -
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
________________________________________________________________________
New Construction: ___________
Demolition: ______________
Expansion: _____________
Installation: _________
Set Backs From Property Lines
Street Side Yard: _________________
Right Side Yard: __________________
Construction
Depth: _________ Height: __________
Units: __________
Area: _____________
Fire Place: ___________
Electric: __________
Source of Water
New Well: _______ Existing Well: ________ Municipal: ________ N/A: _______
TO BE SUBMITTED
Left Side Yard: ____________________
Rear Side Yard: ____________________
Heat: _______ Wood Stove:
Pump: _______
Furnace Wood/Oil: ________
Pellet Stove: _______
Heating System
Width: _________
Stories: _________
Alteration: ____________
Details of Project:
SEWER DISPOSAL
New Septic Existing Septic Municipal
FOUNDATION TYPE
Widened Slab: 4ft Frost Wall: 8 Ft Wall:
Blocking: l.C.F Existing with Engineer Sign Off:
FRAMING TYPE
Wood: Steel: l.C.F. Log:
ROOF TYPE
Pre – Engineered: Rafters:
DURATION
Proposed Start Date: Expected Completion Date
ESTIMATED COST OF WORK:
DECLARATION AND RESPONSIBILITIES OF THE PERMIT HOLDER
By signing the owner/applicant hereby agrees: a) that this is an application only, and until a permit has been issued by the Town of Hampton and received
by the applicant, no part of the intended work shall be undertaken.b) to comply with relevant By-Laws and Regulations.c) that the permit granted under the terms of this application is automatically cancelled if the applicant fails
to conform with any By-Laws or Regulations.d) neither the insurance of this building permit nor the approval of the plans or specifications, relieve the
owner from full compliance with the National Building Code, and applicable Municipal Regulations andBy-laws.
e) that once constructed the applicant agrees to use the structure for the sole purposes indicated in thepreceding application.
f) that this permit expires one year from the date of issuance of the Building Permit andg) all work must be completed within one year of the date of the permit unless written permission for an
extension has been granted by the Building Inspector or designate.
h) if purposed work in any way does not meet the requirements of the aforementioned
By-Laws, there must be a variance application submitted and passed of the particular By-Law
from the Planning Advisory Committee. Until such variance has been granted by that body in
writing, I will not commence work.
i) to contact the Building Inspector:i) At least 48 hours' notice of your intention to start work authorized by the permitii) At least 24 hours' notice for the following is to be provided to the Town Building
Inspector (or designate) in order that proper inspections can be conducted prior tomoving on. With the Failure to provide notice and the continuation of constructionmay result in delays and a request to remove any cover that has been placed overthat which is to be inspected.
I have read and accepted the terms above
DISCLOSURE
The Town of Hampton will not accept responsibility for any damage caused by structures erected in areas subject to flooding, solution collapse, or damages resulting in an act of nature. The information is being collected in order for the Town of Hampton to accept plans and specifications, issued a permit, perform inspections, ect. For such work described in the Zoning By-Law 190-10. Information contained herein will be used to communicate with the relevant Project Contracts, i.e. contractors, engineers, electricians, plumbers, provincial departments. It may be also circlated to otheer Municipal Departments to be used for internal purposes.
For further information or questions regarding the collection of information, please contact Planning and Development for the Town of Hampton at {506) 832-6065 or electronic mail [email protected]
TO BE SUBMITTED
______________________________________________Property owner signature
______________________________________________Building Inspector (or designate)
______________________________Date
______________________________Date
TYPICAL WALL SECTION (EXTERIOR) • SINGLE STOREY (RESIDENTIAL)
Roof Construction FINISH: Shingles __ Metal ___ Other:____ _ SHEATHING: 0S8 __ Plywood __ Boards: __
Thickness: ____ _ TRUSSES: Yes __ No __ (If no enter rafter Info)
RAFTERS: Size _____ Spacing: ____ _ lNSULATION: Type: ___ R Value __ VAPOUR BARRIER:6mm Poly _____ other: ______CEILING FINISH: Gyprock___ Other: ___ _
Type: _____ Thickness _____
Wall Construction EXTERlOR CLADDING:
Vinyl __ Metal __ Clapboard __ Other: _ ____
HOUSE WRAP:
Tyvek __ Typar __ Tarpaper __ Other: ___
EXTRUDED POLYSTYRENE _______
EXPANDED POLYSTYRENE _______ (if applicable)
SHEATHING: OSB _____ Plywood _______ Boards ______
Thickness: ______
WALL STUD: Size ________ Spacing ______INSULATION: Type _____________ R-Value _____
VAPOUR BARRIER: 6mm Poly ___ Other: __ _
INTERIOR FINISH: Gyprock _____ Other ______
Type: _______________ Thickness _______
FOUNDATION FOUNDATION WALL THICKNESS: __________FOOTING WIDTH: ________ ___ _
BELOW GRADE WALL ASSEMBLY: ___ _
BELOW SLAB INSULATION: ______ _
RoofPitch
Eave Protection Required r-:
Vented Soffit
4' Min.or to Solid Rock
Dampproofing
Wall
Roof Ventilation toconform to NBC
FLOOR CONSTRUCTIONFINISH FLOORING: ________________________SUB-FLOOR: Plywood _____OSB ______FLOOR JOISTS: SIZE __________ SPACING ______JOIST HEADER INSULATION: TYPE: ___________ R-VALUE _____
6" x 1/2" Anchor Bolt 7' x 10" O/C Max.
Radon Gas Control to Conform to NBC
Drawings are not to scale
TYPICAL WALL SECTION (EXTERIOR)TWO STOREY (RESIDENTIAL)
Roof ConstructionFINISH: Shingles ____ Metal ____ Other________ _ SHEATHING: OSB __ Plywood ____ Boards: ____
Thickness:._____ _ TRUSSES: Yes __ No __ (If no enter rafter Info) RAFTERS: Size. _____ Spacing ___ __ _ INSULATION: TYPE: ___________ R Value ___ __ VAPOUR BARRlER: 6mm Poly____ Other__ __ _ CEILING FINISH: Gyproc __ other __ _
Type: ____________ Thickness: ______
Wall ConstructionEXTERIOR CLADDING:
Vinyl ___ Metal ____ Clapboard_____ Other:______
HOUSEWRAP:Tyvek ___ Typar ___ Tarpaper _ __ Other: ________ EXTRUDED POLYSTYRENE
EXPANDED POLYSTYRENE (If applicable)SHEATHING: OSB ___ Plywood____ Boards ____
Thickness: __ _ WALL STUD: Size _____ Spacing ____ _
INSULATION: Type ____ R- Value ___ _ VAPOUR BARRIER: 6mm Poly ____ Other_____ _
INTERIOR FINISH: Gyproc _____ Other _________
Type _____ Thickness. ______
FOUNDATIONFOUNDATION WALL THICKNESS: __________ FOOTING WIDTH: __________________ BELOW GRADE WALL ASSEMBLY: _______
BELOW SLAB INSULATION: ______________ _
TO BE SUBMITTED
CONSTRUCTION DETAILS FOR DETACHED DECKS (SINGLE DWELLING UNIT ONLY) Construction details about the deck are required. Please complete the followlng details
(-4"Mex,)
- Galvanized fasteners must be used- All materials to be weather treated
DECK DETAILS
DIMENSIONS: X
HEIGHT {GROUND TO FLOOR)(MAX, 1.8 m):
RAILING HEIGHT:
JOIST SIZE & SPACING:.
JOIST SPAN:
JOIST CANTILEVER: .
BEAM SIZE:
BEAM SPAN:
BEAM CANTILEVER:
POST SIZE:
POST SPACING:
□ BIGFOOT
D SCREW PILES□ DECK BLOCKS DIMENSIONS:
FOUNDATION DEPTH:
MAX. DISTANCE BETWEEN SUPPORT COLUMNS:
7J 1� POST SPACING
___JOIST SPACING
.I JU� Jt.�
r .:,:I ✓ II,.i :u
/DECKBLOCKS
POST
BEAM
r,;:� \.. r:-: �
--t II.a' t.11
ii
(24"Max,)
Drawings are not to scale
JOIST CANTILEVER
Joist Size Joist Spacing 12" 16"
· 2x6 28" 20" 16" 2x8 30" 24" 20" 2x10 39" 30" 24"
24"
, FOUNDATION: □ SONO TUBE DIAMETER
LOT DRAINAGE SKETCH
Sketch must include direction of Stormwater flow and location and grade of Surface Drainage Features.
Sample illustration below. Please fill in following page
Prop
erty
Lin
e
LOT DRAINAGE SKETCH
Sketch must include direction of Stormwater flow and location and grade of Surface Drainage Features.
APPLICANT/OWNER: ______________________________________________________
PID #: _________ _
ADDRESS: ________________________________________________
__________________________________________________________
TYPICAL SITE PLAN (add Accessory Buildings and/or Decks as needed)
Street Name: ____________________________ Drawings are not to scaleNumber of Units:__________________________
TO BE FILLED OUT DURING CONSTRUCTION AND RETURNED
TOWN OF HAMPTON
Application for Occupancy Certificate
REQUIRED FOR ALL NEW RESIDENTIAL DWELLINGS, COMMERCIAL AND ADDITIONS OR RENOVATIONS. A Certificate of Occupancy is required prior to occupancy or use _of a structure. All the following must be inspected and approved before an Occupancy Certificate will be granted.
Building Permit#__________________ Location of Property:_____________________________________________________________________________
Conditions require signature of a licensed installer and a license number attesting that the building meets all provincial codes.
1. Wiring Signature License # Yes No N/A
2. Plumbing Signature License # Yes No N/A
3. WETT Signature License # Yes No N/A
4. Spray FoamInstallation
Signature Yes No N/A
5. MechanicalVentilationRecord Company Manufacturer Model Yes No N/A
6. Heat Pump Make Model Installer Yes No N/A
7. Hot WaterHeater Make Model Yes No N/A
8. I.C.F: ___________________________ ____________________ Yes No N/A
Installer Card
9. Existing Foundation Engineered Sign Off10. Quote sheet or test report for windows11. Engineered Truss & Floor plans included12. Smoke detectors installed13. Operational approval for septic system14. Operational approval for water supply15. All Inspections called for and completed
: Pre-pour Footings : Footings & Foundation Walls : Drainage Tile & Back Fill : Sewer Connection : Pre-Pour Floor : Structural : Insulation & Poly : Pre-Cladding: Final
COMMENTS: Including reasons for non-approval on any of the above
-
-
-
•
•
• -
I certify that the structure identified above has had all required Inspections Completed.
Signature of owner ______________________________________ Date ___________________________
To be filled out and submitted to Building Inspector upon Final Inspection