victron energy ARGOFET Battery Isolator victron energy BLUE POWER 25.6V-200Ah Lithium Smart LiFePO4 victron energy BLUE POWER 25.6V-200Ah Lithium Smart LiFePO4 victron energy BLUE POWER 25.6V-200Ah Lithium Smart LiFePO4 ANL 350A ANL 350A Q1 Conn-G Batt+ Q1 Conn-F Batt- Q1 Conn-G Batt+ Q1 Conn-F Batt- Q1 Conn-L Case ground 0-5 m cable length: 4 x 50SQmm 5-10 m cable length: 4 x 95SQmm Cable length stands for the distance between the battery connections and the Quattro connections !!! Recommendations are without other loads in the system and these also should be taken into account for proper main battery, main fuse & main switch cables !!! Fuse size should be 1x400A or 2x200A per Quattro. Recommended DC cable/fuse size Quattro's AC IN-1 & AC IN-2 both must be protected by a circuit breaker rated at 100A max per phase or less. This depends heavily on the size of the connected power source.The input currents must be adjusted to fit the size of the connected power sources. The breaker and cable size for both AC IN-1 & AC IN-2 should be adjusted accordingly. Recommended AC IN-1 & AC IN-2 cable/breaker size Quattro's With Power assist each Quattro can add 5KW to the output load per phase when needed. Together with the adjustable 100A input this all adds up to the max sum of input and output current of 100+42=142A per phase. An Earth leakage device with breaker or a combination MCB/RCD must be installed on the output. Cable size must be adjusted accordingly. Recommended AC Out-1 cable/breaker size Quattro's AC Out-2 only is available when power is present on AC IN-1 or AC IN-2. During battery operation it will be disconnected. AC Out-2 supports up to 50A per phase and is adjustable. An Earth leakage device with breaker or a combination MCB/RCD must be installed on the output. Cable size must be adjusted accordingly. Recommended AC Out-2 cable/breaker size Quattro's 120/240 VOLT AC IS EXTREMELY HAZARDOUS !!! DO NOT TOUCH ANY LIVE WIRED PARTS OF THE INSTALLATION !!! WHEN IN DOUBT, ALWAYS CONSULT YOUR VICTRON DEALER !!! WARNING Drawing BJE-274A Q2 Conn-G Batt+ Q2 Conn-G Batt+ Q2 Conn-F Batt- Q2 Conn-F Batt- Q2 Conn-L Case ground RESET MPPT + 400A MEGA 100A MEGA Alternator + BUSBAR POSITIVE SUPPLIED UTP CABLE BMS 2A FUSES Spare xxA Battery Pre Main Fuses BMV 100mA 5x20mm Li-DISTRIBUTION VE.Bus MAINS DETECTOR QUATTRO L1 REMOTE PANEL 25.6V-200Ah Smart LiFePO4 POS. NEG. CYRIX Li CHARGE 230 CYRIX Li CHARGE 230 Starter Battery + +B1 +B2 Maximum 5mA BMS ON/OFF 400A MEGA MAIN SWITCH-1 ANL 350A MAIN SWITCH-2 The VE.Bus BMS is enlarged visible in this drawing. The BMS GND is not connected to prevent ground loops. Ground comes through the VE.Bus UTP cable. xxxA MEGA xxxA MEGA xxxA MEGA xxxA MEGA xxxA MEGA MAIN DC DISTRIBUTION BUSBAR POSITIVE BTV CABLE BTV CABLE BTV CABLE BTV CABLE 3 x Lithium MAIN SWITCH-3 0 OFF name 0 OFF 0 OFF name 0 OFF PV BREAKERS/ISOLATORS VE.Bus COLOR CONTROL GX VE-direct-1 VE-direct-2 SMART BATTERY PROTECT 220 SOLAR ARRAY VE.Bus BMS VE.Bus MAINS DETECTOR QUATTRO L1 FROM MPPT FROM QUATTRO L2 B- D+ B+ xx AMP. FUSE IGNITION 30 AC FROM ENGINE+(30) Starter Battery + Charge light ARGOFET ENGINE SYSTEM ALTERNATOR (Lithium Proof) 24V-80A THE BMV SHUNT CAN BE UPGRADED FROM STANDARD 500A TO 1000A. THE BMV SHUNT IS MOUNTED DIRECT ON BOTH BUSBARS. KEEP NEGATIVE BATTERY CABLES ALL AS SHORT AS POSSIBLE AND ALL AT THE SAME LENGTH ! KEEP POSITIVE BATTERY CABLES ALL AS SHORT AS POSSIBLE AND ALL AT THE SAME LENGTH ! The VE.Bus BMS assistant has to be added to each Quattro with Victron's VEConfigure after completion of the split phase setup. Quattro programming with VEConfigure Quattro split phase setup programming The split phase programming has to be completed with Victron's VE.Bus Quick Configure before the VE.Bus BMS assistant is loaded into each Quattro ! M8 CIRCULAR CONNECTOR M8 CIRCULAR CONNECTOR M8 CIRCULAR CONNECTOR M8 CIRCULAR CONNECTOR The BatteryProtect must be programmed for Li-Ion mode-C and 24 Volt either through programming on the device itself or with a Bluetooth enabled smartphone or tablet. Connect the load disconnect output of the VE.Bus BMS to Remote H terminal. CENTRAL NEGATIVE BUSBAR OFF ON OFF ON INVERTER/CHARGER QUATTRO-1 / L1 5KW/24V/120V-60Hz AC INVERTER/CHARGER QUATTRO-2 / L2 5KW/24V/120V-60Hz AC Quattro-1 AC IN-2 Quattro-1 AC IN-1 VE.Bus Master Slave cable Quattro-1 AC OUT-1 Quattro-1 AC OUT-2 Quattro-1 AC IN-2 Quattro-1 AC IN-1 VE.Bus to CCGX VE.Bus mains detector to BMS VE.Bus to CCGX BMV-712 SMART SMART MPPT SmartSolarcharge controller MPPT 100 | 50 12/24V 50A Bulk Absorbtion Float BATTERY PV + - - + victron energy Battery 100V 50A PV IP43 ! i max VE-direct FUSE CCGX 1A 5x20mm CCGX POWER + VRM WORLD ETHERNET V+ GND BTV CABLE BTV CABLE BMV POWER + ISOLATION TRANSFORMER OR GALVANIC ISOLATOR SHOULD BE INSERTED HERE IF NEEDED, INCLUDING NECESSARY BREAKERS. SHORE POWER CONNECTION Drawing BJE-274A 125/250V Easy Lock 50A AC BREAKERS TOWARDS QUATTRO'S MAIN INCOMING Shore Generator power power 0 OFF name 0 OFF name Quattro-1 AC out-1 Quattro-2 AC out-1 0 OFF name 0 OFF name Quattro's 240V out 0 OFF name 0 OFF name SUPPLY 2 X 120VAC AND 1 X 240VAC QUATTRO'S AC OUT-1 SPLIT PHASE 0 OFF name 0 OFF 0 OFF name 0 OFF 0 OFF MCB MCB 0 OFF name 0 OFF 0 OFF MCB MCB Quattro-1 AC IN-2 Quattro-1 AC IN-1 Quattro-2 AC IN-2 Quattro-2 AC IN-1 0 OFF name 0 OFF 0 OFF name 0 OFF MCB MCB MCB 0 OFF name 0 OFF name Quattro-1 AC out-2 Quattro-2 AC out-2 0 OFF name 0 OFF name Quattro's 240V out 0 OFF name 0 OFF name SUPPLY 2 X 120VAC AND 1 X 240VAC QUATTRO'S AC OUT-2 SPLIT PHASE 0 OFF name 0 OFF 0 OFF name 0 OFF 0 OFF name 0 OFF NEUTRAL LINK MCB MCB MCB 120V L1 Switched load-1 120V L1 Switched load-2 120V L2 Switched load-1 120V L2 Switched load-2 240V L1-L2 Switched load-1 240V L1-L2 Switched load-2 120V L1 No Break load-1 120V L1 No Break load-2 120V L2 No Break load-1 120V L2 No Break load-2 240V L1-L2 No Break load-1 240V L1-L2 No Break load-2 NEUTRAL LINK 120-240V / 60Hz AC GENERATOR 8KW 120/240VAC Shore power 120/240VAC Generator 120/240VAC Quattro-2 AC IN-2 Quattro-2 AC IN-1 Quattro-2 AC OUT-1 Quattro-2 AC OUT-2 Quattro-1 AC OUT-1 Quattro-1 AC OUT-2 When operating in inverter mode, the Neutral output of a inverter/charger must be connected to ground to guarantee proper functioning of a GFCI or RCD device. In case of a split phase supply the Neutral also must be grounded. The primary Case ground connection from a inverter charger like a Multi or a Quattro, must be connected to the Central Negative Busbar of the DC system. Size of this cable must be identical to connected DC negative. IMPORTANT INFORMATION ! KEEP ALL QUATTRO DC POWER CABLES AS SHORT AS POSSIBLE AND ALL AT THE SAME LENGTH ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! NEUTRAL LINK NEUTRAL LINK color control Inverting AC Input AC Loads 0W 230W 75% DC Power PV-Charger 745W VE.Bus BMS mains detector inside Quattro L1 INTERNAL ALTERNATOR FUSE 100A AMI MAIN DC DISTRIBUTION ENGINE 100A MEGA BATTERY ISOLATOR Quattro 24 |5000 |120 charger inverter inverter on overload low battery temperature mains on bulk absorption float I on charger only O off .battery charger .powerassist .transfer switch .three phase .sinewave inverter .parallel connectable connectable AC transfer capacity: 2x100A | Inverter 120V VOLT VA AMP www.victronenergy.com CE victron energy BLUE POWER BATTERY _ _ BATTERY + + BATTERY BATTERY Quattro 24 |5000 |120 charger inverter inverter on overload low battery temperature mains on bulk absorption float I on charger only O off .battery charger .powerassist .transfer switch .three phase .sinewave inverter .parallel connectable connectable AC transfer capacity: 2x100A | Inverter 120V VOLT VA AMP www.victronenergy.com CE victron energy BLUE POWER BATTERY _ _ BATTERY + + BATTERY BATTERY Load 1 + Load 2 + Load 3 + Load 4 + Load 5 + Quattro-1 Batt + Quattro-1 Batt + Quattro-2 Batt + Quattro-2 Batt + BP220 GND- CCGX- CYRIX LI- ARGO FET- Q2 Conn-F Batt- Q2 Conn-F Batt- Q2 Conn-L Case ground Q1 Conn-L Case ground Q1 Conn-F Batt- Q1 Conn-F Batt- Alternator- Engine- MPPT- Load 1 - Load 2 - Load 3 - Load 4 - Load 5 - OFF ON ALARM LED + BMS POWER+ BMS LOAD DISCONNECT BMS CHARGE DISCONNECT ALARM LED -

Upload: others

Post on 07-Sep-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: RESET - Victron Energy...MEGA MAIN SWITCH-1 ANL 350A MAIN SWITCH-2 The VE.Bus BMS is enlarged visible in this drawing. The BMS GND is not connected to prevent ground loops. Ground

victron energyBLUE POWER

www.victronenergy.com

ARGOFET Battery Isolator100A 2 Output

ENERGIZE

100A 3 Output

200A 2 Output

200A 3 Output

GROUNDOUTPUT-2 OUTPUT-1 INPUT

victron energyB

LU

E P

OW

ER

25.6V-200A

hLithium

Sm

art LiFePO

4

victron energyB

LU

E P

OW

ER

25.6V-200A

hLithium

Sm

art LiFePO

4

victron energyB

LU

E P

OW

ER

25.6V-200A

hLithium

Sm

art LiFePO

4

ANL

350A

ANL

350A

Q1 Conn-G Batt+

Q1 Conn-F Batt-

Q1 Conn-G Batt+

Q1 Conn-F Batt-

Q1 Conn-L Case ground

0-5 m cable length: 4 x 50SQmm5-10 m cable length: 4 x 95SQmmCable length stands for the distance between thebattery connections and the Quattro connections !!!Recommendations are without other loads in thesystem and these also should be taken intoaccount for proper main battery, main fuse & mainswitch cables !!!Fuse size should be 1x400A or 2x200A per Quattro.

Recommended DC cable/fuse size Quattro's

AC IN-1 & AC IN-2 both must be protectedby a circuit breaker rated at 100A max perphase or less. This depends heavily on thesize of the connected power source.Theinput currents must be adjusted to fit thesize of the connected power sources. Thebreaker and cable size for both AC IN-1 &AC IN-2 should be adjusted accordingly.

Recommended AC IN-1 & AC IN-2 cable/breaker size Quattro'sWith Power assist each Quattro can add

5KW to the output load per phase whenneeded. Together with the adjustable 100Ainput this all adds up to the max sum ofinput and output current of 100+42=142Aper phase. An Earth leakage device withbreaker or a combination MCB/RCD mustbe installed on the output. Cable size mustbe adjusted accordingly.

Recommended AC Out-1 cable/breaker size Quattro'sAC Out-2 only is available when power ispresent on AC IN-1 or AC IN-2.During battery operation it will bedisconnected. AC Out-2 supports up to 50Aper phase and is adjustable.An Earth leakage device with breaker or acombination MCB/RCD must be installedon the output. Cable size must be adjustedaccordingly.

Recommended AC Out-2 cable/breaker size Quattro's120/240 VOLT AC IS EXTREMELYHAZARDOUS !!!DO NOT TOUCH ANY LIVE WIREDPARTS OF THE INSTALLATION !!!WHEN IN DOUBT, ALWAYS CONSULTYOUR VICTRON DEALER !!!

WARNING

Drawing BJE-274A

Q2 Conn-G Batt+

Q2 Conn-G Batt+

Q2 Conn-F Batt-

Q2 Conn-F Batt-

Q2 Conn-L Case ground

RESET

60 A

MP

ER

ETH

ER

MA

L C

IRC

UIT

BR

EA

KE

R

2850

60F

L O A D

BAT

MPPT +

400AMEGA

100AMEGA Alternator +

BUSBARPOSITIVE

SUPPLIED UTP CABLE

BMS 2A

FUSES

Spare xxA

Battery Pre Main Fuses

BMV 100mA

5x20mm

Li-DISTRIBUTION

VE.Bus MAINS DETECTOR QUATTRO L1REMOTE PANEL

25.6V-200AhSmart LiFePO4

POS. NEG.

CYRIX Li CHARGE 230

CYRIX LiCHARGE

230

Starter Battery ++B1+B2

Maximum 5mA

BMS ON/OFF

400AMEGA

MAIN SWITCH-1

ANL

350A MAIN SWITCH-2

The VE.Bus BMS is enlargedvisible in this drawing.The BMS GND is not connectedto prevent ground loops.Ground comes through theVE.Bus UTP cable.

xxxAMEGA

xxxAMEGA

xxxAMEGA

xxxAMEGA

xxxAMEGA

MAIN DCDISTRIBUTION

BUSBARPOSITIVE

BTV CABLEBTV CABLE

BTV CABLEBTV CABLE

3 x Lithium

MAIN SWITCH-3

0 OFF

name

0 OFF 0 OFF

name

0 OFF

PV BREAKERS/ISOLATORS

VE

.Bus

COLOR CONTROL GX

VE

-direct-1

VE

-direct-2

SMART BATTERY PROTECT 220

SOLAR ARRAY

VE.Bus BMS

VE.Bus MAINS DETECTOR QUATTRO L1

FROM MPPT

FROM QUATTRO L2

B-D+B+

xx AMP.FUSE

IGNITION

30 AC

FROM ENGINE+(30)

Starter Battery +

Charge lightARGOFET

ENGINE SYSTEM

ALTERNATOR (Lithium Proof)

24V-80A

THE BMV SHUNT CAN BE UPGRADEDFROM STANDARD 500A TO 1000A.THE BMV SHUNT IS MOUNTEDDIRECT ON BOTH BUSBARS.

KEEP NEGATIVE BATTERY CABLESALL AS SHORT AS POSSIBLE ANDALL AT THE SAME LENGTH !

KEEP POSITIVE BATTERY CABLESALL AS SHORT AS POSSIBLE ANDALL AT THE SAME LENGTH !

The VE.Bus BMS assistant has to be addedto each Quattro with Victron's VEConfigureafter completion of the split phase setup.

Quattro programming with VEConfigure

Quattro split phase setup programmingThe split phase programming has to becompleted with Victron's VE.Bus QuickConfigure before the VE.Bus BMS assistantis loaded into each Quattro !

M8 CIRCULARCONNECTOR

M8 CIRCULARCONNECTOR

M8 CIRCULARCONNECTOR

M8 CIRCULARCONNECTOR

The BatteryProtect must beprogrammed for Li-Ion mode-Cand 24 Volt either throughprogramming on the deviceitself or with a Bluetoothenabled smartphone or tablet.Connect the load disconnectoutput of the VE.Bus BMS toRemote H terminal.

CENTRALNEGATIVE BUSBAR

OFF

ON

OFF

ON

INVERTER/CHARGERQUATTRO-1 / L1 5KW/24V/120V-60Hz AC

INVERTER/CHARGERQUATTRO-2 / L2 5KW/24V/120V-60Hz AC

Quattro-1 AC IN-2

Quattro-1 AC IN-1

VE.Bus Master Slave cable

Quattro-1 AC OUT-1

Quattro-1 AC OUT-2

Quattro-1 AC IN-2

Quattro-1 AC IN-1

VE.Bus to CCGX

VE.Bus mains detector to BMS

VE.Bus to CCGX

BMV-712 SMART

SELECTSETUP

BATTERY MONITORBMV-712 SMART

VMAIN

victron energyBLUE POWER

SMART MPPT

SmartSolar charge controllerMPPT 100 | 50

12/24V 50A

Bul

k

Abs

orbt

ion

Floa

t

BATTERY PV

+ - - +

victron energyBLUE POWER

Battery100V 50APV

IP43! i

max

VE

-direct

FUSE

CCGX 1A

5x20mmCCGX POWER +

VRMWORLDE

THE

RN

ET

V+GND

BTV

CA

BLE

BTV

CA

BLE

BMV POWER +

ISOLATION TRANSFORMER ORGALVANIC ISOLATOR SHOULD BEINSERTED HERE IF NEEDED,INCLUDING NECESSARYBREAKERS.

SHORE POWERCONNECTION

Drawing BJE-274A

125/250VEasy Lock

50A

AC BREAKERSTOWARDS

QUATTRO'S

MAIN INCOMING

Shore Generatorpower power

0 OFF

name

0 OFF

name

Quattro-1AC out-1

Quattro-2AC out-1

0 OFF

name

0 OFF

name

Quattro's240V out

0 OFF

name

0 OFF

name

SUPPLY 2 X 120VAC AND 1 X 240VACQUATTRO'S AC OUT-1 SPLIT PHASE

0 OFF

name

0 OFF

0 OFF

name

0 OFF0 OFF

MCBMCB

0 OFF

name

0 OFF0 OFF

MCBMCB

Quattro-1 AC IN-2

Quattro-1 AC IN-1

Quattro-2 AC IN-2

Quattro-2 AC IN-1

0 OFF

name

0 OFF 0 OFF

name

0 OFF

MCB MCB MCB

0 OFF

name

0 OFF

name

Quattro-1AC out-2

Quattro-2AC out-2

0 OFF

name

0 OFF

name

Quattro's240V out

0 OFF

name

0 OFF

name

SUPPLY 2 X 120VAC AND 1 X 240VACQUATTRO'S AC OUT-2 SPLIT PHASE

0 OFF

name

0 OFF0 OFF

name

0 OFF 0 OFF

name

0 OFF

NEUTRAL LINK

MCB MCB MCB

120V L1 Switched load-1120V L1 Switched load-2120V L2 Switched load-1120V L2 Switched load-2

240V L1-L2 Switched load-1240V L1-L2 Switched load-2

120V L1 No Break load-1120V L1 No Break load-2120V L2 No Break load-1120V L2 No Break load-2

240V L1-L2 No Break load-1240V L1-L2 No Break load-2

NEUTRAL LINK

120-240V / 60Hz ACGENERATOR 8KW

120/240VAC Shore power 120/240VAC Generator

120/240VAC

Quattro-2 AC IN-2

Quattro-2 AC IN-1

Quattro-2 AC OUT-1

Quattro-2 AC OUT-2

Quattro-1 AC OUT-1

Quattro-1 AC OUT-2

When operating in inverter mode, the Neutral output ofa inverter/charger must be connected to ground toguarantee proper functioning of a GFCI or RCD device.In case of a split phase supply the Neutral also mustbe grounded.The primary Case ground connection from a invertercharger like a Multi or a Quattro, must be connected tothe Central Negative Busbar of the DC system. Size ofthis cable must be identical to connected DC negative.

IMPORTANT INFORMATION !

KEEP ALL QUATTRO DC POWERCABLES AS SHORT AS POSSIBLEAND ALL AT THE SAME LENGTH !

IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION ! IMPORTANT INFORMATION !

NEUTRAL LINK NEUTRAL LINK

color

victron energyBLUE POWER

control

victron energy

InvertingAC Input AC Loads

0W 230W

75%- +

340W25.6V 13.2A -155W

DC Power

L1: 0WL2: 0W

L1: 127WL2: 103W

PV-Charger

745W

VE.Bus BMS mainsdetector inside Quattro L1

INTERNALALTERNATOR

FUSE

100AAMI

MAIN DC DISTRIBUTION ENGINE

100AMEGA

BATTERYISOLATOR

Quattro24 |5000 |120

charger inverterinverter onoverloadlow batterytemperature

mains onbulkabsorptionfloat

I on

charger onlyO off

.battery charger

.powerassist.transfer switch.three phase

.sinewave inverter

.parallel connectable connectable

AC transfer capacity: 2x100A | Inverter 120V

VOLT

VA AM

P

www.victronenergy.com

CE

victron energyBLUE POWER

Battery

AC in 1

AC in 2

AC out 1

AC out 2

ON

1 2S1 S2

TRICKLECHARGE

V-SENSE T-SENSE AUX1 AUX2 RELAYGND

CHARGETRICKLE

K1 K2+ - + - + - + - + - NC NOS1 S2 + COM NC NO COM

BATTERY__

BATTERY++

NEUT

RAL

GROUND

AC IN-1 AC OUT-1 AC OUT-2 AC IN-2 GROUND

LIN

E

NEUT

RAL

GROUND

LIN

E

LIN

E

L N L N L L N

OUT1

OUT2

OUT1-2

IN1

IN1

IN2

IN2

BATTERY

BATTERY

VE.Bus-1 VE.Bus-2

LIN

E

NEUT

RAL

victron energyBLUE POWER

VE.Bus BMSMains detector

Quattro24 |5000 |120

charger inverterinverter onoverloadlow batterytemperature

mains onbulkabsorptionfloat

I on

charger onlyO off

.battery charger

.powerassist.transfer switch.three phase

.sinewave inverter

.parallel connectable connectable

AC transfer capacity: 2x100A | Inverter 120V

VOLT

VA AM

P

www.victronenergy.com

CE

victron energyBLUE POWER

Battery

AC in 1

AC in 2

AC out 1

AC out 2

ON

1 2S1 S2

TRICKLECHARGE

V-SENSE T-SENSE AUX1 AUX2 RELAYGND

CHARGETRICKLE

K1 K2+ - + - + - + - + - NC NOS1 S2 + COM NC NO COM

BATTERY__

BATTERY++

NEUT

RAL

GROUND

AC IN-1 AC OUT-1 AC OUT-2 AC IN-2 GROUND

LIN

E

NEUT

RAL

GROUND

LIN

E

LIN

E

L N L N L L N

OUT1

OUT2

OUT1-2

IN1

IN1

IN2

IN2

BATTERY

BATTERY

VE.Bus-1 VE.Bus-2

LIN

E

NEUT

RAL

Load 1 +

Load 2 +

Load 3 +

Load 4 +

Load 5 +

Quattro-1 Batt +

Quattro-1 Batt +

Quattro-2 Batt +

Quattro-2 Batt +

BP220 GND-CCGX-

CYRIX LI-

ARGO FET-

Q2 Conn-F Batt-

Q2 Conn-F Batt-

Q2 Conn-L Case ground

Q1 Conn-L Case ground

Q1 Conn-F Batt-

Q1 Conn-F Batt-

Alternator-

Engine-

MPPT-

Load 1 - Load 2 -

Load 3 -

Load 4 -

Load 5 -

OFF

ONALARM LED +

BMS POWER+BMS LOAD DISCONNECTBMS CHARGE DISCONNECT

ALARM LED -