reserve societe sumare payload. reserve societe contents objectives. sensors choice. sensors...
TRANSCRIPT
![Page 1: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning](https://reader035.vdocuments.us/reader035/viewer/2022062322/5697bfd51a28abf838cad91c/html5/thumbnails/1.jpg)
RESERVE SOCIETE
SUMARE PAYLOAD
TMS SAS 00/S/EDA/NC/088 - MP
![Page 2: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning](https://reader035.vdocuments.us/reader035/viewer/2022062322/5697bfd51a28abf838cad91c/html5/thumbnails/2.jpg)
RESERVE SOCIETE
CONTENTS
• Objectives.
• Sensors choice.
• Sensors performances.
• Implant possibilities.
• Sensors conditioning.
• Schedule.
• Sensors integration drawings.
• Fins navigation trials.
• Fresh water tank measurement sensors.
2
TMS SAS 00/S/EDA/NC/088 - MP
![Page 3: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning](https://reader035.vdocuments.us/reader035/viewer/2022062322/5697bfd51a28abf838cad91c/html5/thumbnails/3.jpg)
RESERVE SOCIETE
OBJECTIVES
The “Payload” will assume two main operational functions.
• Monitoring of the volumetric evolution of sand banks.
• Obstacles avoidance.
3
TMS SAS 00/S/EDA/NC/088 - MP
![Page 4: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning](https://reader035.vdocuments.us/reader035/viewer/2022062322/5697bfd51a28abf838cad91c/html5/thumbnails/4.jpg)
RESERVE SOCIETE
SENSORS CHOICE
Altimeter.
Acoustic high frequency transducer ( Resolution)
Obstacles avoidance.
The inner Mauve transducer is not available (Software limits / Discrimination).
The transducer is the same than for altimeter.
4
TMS SAS 00/S/EDA/NC/088 - MP
![Page 5: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning](https://reader035.vdocuments.us/reader035/viewer/2022062322/5697bfd51a28abf838cad91c/html5/thumbnails/5.jpg)
RESERVE SOCIETE
5
TMS SAS 00/S/EDA/NC/088 - MP
SENSORS PERFORMANCES
Measurement limit : 50 m
Measurement mode : Free run
Measurement speed : 10 Hz
Power supply : 12 or 24 VDC
Interface : RS 232 or RS 485
Frequency : 500 kHz
Conical beam : 6°
![Page 6: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning](https://reader035.vdocuments.us/reader035/viewer/2022062322/5697bfd51a28abf838cad91c/html5/thumbnails/6.jpg)
RESERVE SOCIETE
TMS SAS 00/S/EDA/NC/088 - MP
IMPLANT POSSIBILITIES
1 : Risk on Payload structure (depth)
Obstacle avoidance sensor not possible.
2 : Risk on launching.
3 : chosen solution
6
1
2
3
![Page 7: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning](https://reader035.vdocuments.us/reader035/viewer/2022062322/5697bfd51a28abf838cad91c/html5/thumbnails/7.jpg)
RESERVE SOCIETE
SENSORS CONDITIONING
Conditioning electronic : two output
Two output are available on MMNS
1 RS 232
1 RS 485
The two electronic signal conditioning units will be connected on these outputs
7
TMS SAS 00/S/EDA/NC/088 - MP
![Page 8: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning](https://reader035.vdocuments.us/reader035/viewer/2022062322/5697bfd51a28abf838cad91c/html5/thumbnails/8.jpg)
RESERVE SOCIETE
SCHEDULE
8
TMS SAS 00/S/EDA/NC/088 - MP
2000 20015 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12
fins dummy productionVillefranche Fins dummy navigation sea trials Measurement system specificationPayload implant proposalfins prototype productionVillefranche Fins prototype navigation sea trials Software / Payload validatePayload productionFresh water tank Payload measurementVillefranche sea trials
![Page 9: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning](https://reader035.vdocuments.us/reader035/viewer/2022062322/5697bfd51a28abf838cad91c/html5/thumbnails/9.jpg)
RESERVE SOCIETE
SENSORS INTEGRATION.
4 configurations will be tested at sea.
• 1 :Fins 60 mm long in front of the payload.
• 2 :Fins 60 mm long in back of the payload.
• 3 :Fins 120 mm long in front of the payload.
• 4 :Fins 120 mm long in back of the payload.
9
TMS SAS 00/S/EDA/NC/088 - MP
![Page 10: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning](https://reader035.vdocuments.us/reader035/viewer/2022062322/5697bfd51a28abf838cad91c/html5/thumbnails/10.jpg)
RESERVE SOCIETE
1 :Fins 60 mm long in front of the payload.10
TMS SAS 00/S/EDA/NC/088 - MP
6°
6°
FRONT VIEWSIDE VIEW
TOP VIEW
![Page 11: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning](https://reader035.vdocuments.us/reader035/viewer/2022062322/5697bfd51a28abf838cad91c/html5/thumbnails/11.jpg)
RESERVE SOCIETE
1 :Fins 60 mm long in back of the payload.11
TMS SAS 00/S/EDA/NC/088 - MP
6°
6°
FRONT VIEWSIDE VIEW
TOP VIEW
![Page 12: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning](https://reader035.vdocuments.us/reader035/viewer/2022062322/5697bfd51a28abf838cad91c/html5/thumbnails/12.jpg)
RESERVE SOCIETE
3 :Fins 120 mm long in front of the payload.12
TMS SAS 00/S/EDA/NC/088 - MP
6°
6°
FRONT VIEWSIDE VIEW
TOP VIEW
![Page 13: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning](https://reader035.vdocuments.us/reader035/viewer/2022062322/5697bfd51a28abf838cad91c/html5/thumbnails/13.jpg)
RESERVE SOCIETE
4 :Fins 120 mm long in back of the payload.13
TMS SAS 00/S/EDA/NC/088 - MP
6°
6°
FRONT VIEWSIDE VIEW
TOP VIEW
![Page 14: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning](https://reader035.vdocuments.us/reader035/viewer/2022062322/5697bfd51a28abf838cad91c/html5/thumbnails/14.jpg)
RESERVE SOCIETE
fins with their moulds14
TMS SAS 00/S/EDA/NC/088 - MP
![Page 15: RESERVE SOCIETE SUMARE PAYLOAD. RESERVE SOCIETE CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning](https://reader035.vdocuments.us/reader035/viewer/2022062322/5697bfd51a28abf838cad91c/html5/thumbnails/15.jpg)
RESERVE SOCIETE
FRESH WATER TANK
MEASUREMENT SENSORS
15
TMS SAS 00/S/EDA/NC/088 - MP
Computer
Signal generatorPower amplifier
Amplifier
Oscilloscope
Rotating unit
Reference hydrophone