research clinical industrial · milk-fat centrifuge ultra & supra series high speed,...
TRANSCRIPT
Selection Guide for Hanil Scientific Centrifuge
R E S E A R C H
C L I N I C A L
INDUSTRIAL
HANIL SCIENTIFIC INC.
Swing-out rotorSpin horizontally. Better separation of liquids, to be resolved in density gradients.Fixed angle rotorBuckets are rigidly attached to rotor and spin at fixed angle, usually 45 degrees. Withstand higher gravitational forces which allows high-throughput applications.
Purpose Speed Related Model Rotor Type
DNA/RNA precipitation 10,000 ~ 20,000 xg Smart series Fixed Angle
Subcellular organelleDiameter 1~2 µm 10,000 xg Combi series
Supra series Fixed Angle
Subcellular organelleDiameter <0.1µm 100,000 xg Supra series
Ultra 5.0 Fixed Angle
Antibody separation 10,000 xg Combi seriesSupra series Fixed Angle
Cell HarvestMammalian, Diameter >10 µm
500 ~ 2,000 xg
CombiSupra series Fixed Angle
Cell HarvestE.Coli, Diameter 1 µm 10,000 xg Combi
Supra series Fixed Angle
Protein purification 200,000 ~ 300,000 xg Ultra 5.0 Fixed Angle
Concentrating virus 100,000 ~ 150,000 xg Ultra 5.0 Fixed Angle
Microalgae separation 10,000 xg CombiSupra series
Fixed AngleSwing-out
Plant extract separation 1,000 ~ 2,000 xg Combi series Fixed Angle
Swing-out
NOTE : The maximum g-force and rotor type mentioned above, would be different dependent on your own purpose and sample type.
RESEARCHU S E
From microcentrifuge to advanced floor models, a wide range of centrifuges are offered to satisfy different application requirements with consistent results.
Smart SeriesMicro Centrifuges
Ultra & Supra SeriesHigh speed, Floor-standing Centrifuges
Combi SeriesMulti-purpose, Table-top Centrifuges
Technical Information
T. +82-2-3472-0727 │ [email protected] │ www.ihanil.com
Purpose Speed Related Model Rotor Type
Serum / Plasma separation 1,500 ~2,000 xg
Fleta seriesCombi seriesComponent series
Swing-out
Blood Bag separation 2,000 ~5,000 xg Component series Swing-out
Total Lipid extraction 1,000 ~2,000 xg
Fleta seriesCombi series Swing-out
PRPPlatelet Rich Plasma
500 ~2,000 xg Fleta series Swing-out
PRFPlatelet Rich Fibrin
1,000 ~5,000 xg Fleta series Swing-out
Sputum separation 2,000 xg Combi series Swing-out
Blood cross matching 1,000 xg SeroSpin II Fixed Angle
Human hair 1,000 ~2,000 xg Combi series Swing-out
Cytology / Pathology 500 ~ 1,000 xg CellSpin Fixed Angle
Hematocrit 10,000 ~15,000 xg HematoSpin II Fixed Angle
HANIL SCIENTIFIC INC.
The benefit of swing-out rotor at clinical laboratories is, generating sediment of liquid samples horizontally for easy separation of the phases.Dual deceleration of Hanil centrifuge profile for gentle and quick running, which avoids resuspending of sediment.
NOTE : The maximum g-force and rotor type mentioned above, would be different dependent on your own purpose and sample type.
Fleta SeriesGeneral Clinical Centrifuges
Spin SeriesHematoSpin II / SeroSpin II / CellSpin
Component SeriesBlood Banks or Large Capacity
C L I N I C A L U S E
Technical Information
With confirming international standards and regulations, a wide variety of centrifuges are offered to enhance the clinical workflow with solid reliability and outstanding performance.
T. +82-2-3472-0727 │ [email protected] │ www.ihanil.com
HA-400Milk-fat Centrifuge
Ultra & Supra SeriesHigh speed, Floor-standing Centrifuges
J1250Industrial Continuous Centrifuge
Purpose Speed Related Model Rotor Type
Oil separation from POME* 3,000 ~13,000 xg J1250 Tubular
Water separation from fuel oil 500 ~1,000 xg J1250 Tubular
Milk-fat separation 500 ~700 xg HA400 Swing-out
Skim milk separation 5,000 ~10,000 xg
Combi seriesSupra series Swing-out
Fruit juice pelleting 2,000 ~3,000 xg
Combi seriesSupra series Swing-out
Silica separation 7,000 ~10,000 xg J1250 Tubular
Nano particle separation <100 nm
150,000 ~200,000 xg Ultra5.0 Fixed Angle
Sea water separation 10,000 xg J1250 Tubular
Cellulose separation 10,000 xg J1250 Tubular
Mud separation 2,000 ~3,000 xg J1250 Tubular
Whether it is capacity or efficiency, our unique centrifuges can satisfy the most demanding industrial settings with robust structure and proven results.
HANIL SCIENTIFIC INC.
The tubular type industrial centrifuge is used for continuous treament which separates the sample to two phases, liquid and solid.Installation of water jacket allows to cool down the sample during rotation of bowl.
NOTE : The maximum g-force and rotor type mentioned above, would be different dependent on your own purpose and sample type.
* POME : Palm Oil Mill Effluent
Technical Information
INDUSTRIALU S E
T. +82-2-3472-0727 │ [email protected] │ www.ihanil.com
HANIL SCIENTIFIC INC. T. +82-2-3472-0727 │ [email protected] │ www.ihanil.com
Selection Guide
Centrifuge Group Micro High Speed,Floor Standing
Multi-purpose,Table-top
Clinical Application,Swing-out Industrial
Model
Smart13
Smart 15 Plus
SmartR17 Plus
Ultra5.0
SupraR30
SupraR22
SupraR17
SupraR12
CombiR515
Combi508
Fleta4
Fleta5
ComponentwR
ComponentR6
ComponentR12 HA-400 J1250
Max. RPM
Fixed Angle 13,500 15,000 17,000 50,000 30,000 22,000 17,000 12,000 15,000 8,000 4,000 - - - - - 15,000Swing-out - - - - - - - - 4,500 4,000 4,000 5,500 4,500 5,000 4,800 1,700 -
Refrigeration - - + + + + + + + - - - + + + - +Vacuum - - - + + - - - - - - - - - - - -by Max. g-force (RCF, xg)
Fixed AngleRotor
250,000 xg 254,300
100,000 xg 106,600
50,000 xg 57,300
30,000 xg 34,200
25,000 xg 21,000 23,000 22,200 26,600
10,000 xg 12,000 8,200 15,800(T)
5,000 xg 2,700
0
Swing-outRotor
7,500 xg 7,200 7,400
6,000 xg 6,200
5,000 xg 4,300 5,000
3,500 xg 3,500 3,200
2,000 xg
0 830
by Sample Container
Micro Plates - - - - - - - - S S - S S - - - -
MicroTubes
PCR Strip F F F - - - - - F F - - - - - - -0.2/0.5 mL F F F - F F F - F F - - - - - - -1.5/2.0 mL F F F F F F F - F F - - - - - - -Micro filter tube - F F - F F F - F F - - - - - - -5 mL F - - - - - - - - - - - - - - - -
Tubes
3 / 4 / 5 mL - - - - - - - - S S - S S - - - -10 / 15 mL - - - F F F F - F S F S F S S S - - - -15 mL conical - - - - F F F - F S F S F S S S - - - -25 mL - - - - - - - - - - S - - - - - -38.5 mL - - - F - - - - - - - - - - - - -50 mL - - - F F F F - F S F S S S S - - - -50 mL conical - - - - F F F - F S F S S S S - - - -85 /100 mL - - - F F F F - F S F S S - - - - S -225 mL conical - - - - - - - - S S - - S - - - -250 mL - - - F F F F F F S S - - S - - - -500 mL - - - - F F - F S S - - S - - - -500 mL conical - - - - - - - - S S - - S - - - -750 mL - - - - - - - - S S - - S - - - -1,000 mL - - - - F F - F - - - - - S - - -
Syringe or PRP - - - - - - - - - - S S - - - - -Blood Bags - - - - - - - - - - - - - S S - -Continuous (Tubular) - - - - - - - - - - - - - - - - T
* F stands for Fixed angle rotor, S for Swing-out rotor and T for Tubular rotor.
HANIL SCIENTIFIC INC.16 Arayukro, Gimpo 10136, Rep. of KOREA T. +82-2-3472-0727 F. +82-31-985-9158 [email protected]
Copyright(C) 2018 Hanil Scientific Inc. All rights reserved. 018HS04B
DISTRIBUTION
Products of Hanil Scientific ihanil.com
Sample Separation
Sample Concentration
Sample Culture
Laboratory Fermentor
CO2 Incubator
Upright Type Deep Freezers
Chest Type Deep Freezers
Gas Purging Evaporation Concentrator
Concentrators & Freeze Dryers
Laboratory Centrifuges
Continuous Centrifuge
Sample Storage