Request For Qualifications-Based Proposals for Construction Contract Farmington Civic Center Renovations & Expansion
PROJECT NO. CCEXP, RFP NO. 18-122315
IMMEDIATE ATTENTION ADDENDUM ONE
August 25, 2017
Receipt of this addendum shall be noted on Page 3 in the Request for Qualifications-based Proposal documents for the above referenced RFQP. The addendum is hereby made part of the Contract Documents to the same extent as though it were originally included therein. Refer to "Submittal Form" for acknowledgment of addenda. All Contractors, Subcontractors and suppliers are reminded that they shall be familiar with all addenda items (as well as all parts of the construction documents) so as to understand the extent of their work and its interrelation with other trades. To all bidders for furnishing all labor and materials necessary for the following contract: CIVIL ITEMS CIVIL SHEETS ITEM AD1-C1 Clarification: in all sheets where metal handrails or guardrails are referenced, handrails or guardrails must be primed and painted. The paint color shall be coordinated between the City of Farmington and the Architect. LANDSCAPING ITEMS PROJECT MANUAL ITEM AD1-L1 Section 01 56 39 – Temporary Tree Protection Delete section 01 56 39 – Temporary Tree Protection in its entirety from the project manual. Contractor shall refer to TREE PROTECTION NOTES on SHEET ADS101 for this scope of work. DRAWING SHEETS ITEM AD1-L2 Sheet LS102 – CONSTRUCTION PLAN NOTES Add ENLARGEMENT GENERAL NOTE "E", which shall read as follows: "SEE SHEET E504 FOR ADDITIONAL GROUNDING AND BONDING REQUIREMENTS OF FOUNTAIN EQUIPMENT AND PAVING AS PART OF THE ADDITIVE ALTERNATE."
CITY OF FARMINGTON
800 Municipal Drive Farmington, NM 87401-2663
(505) 599-1373 Fax (505) 599-1377
http://www.fmtn.org
AD1-2
ITEM AD1-L3 Sheet LS101 – Construction Plan South Revise a portion of SHEET LS101 - CONSTRUCTION PLAN SOUTH, per SKL-001 attached to this addendum. ITEM AD1-L4 Sheet LS501 – Planting Plan South Revise SHEET TITLE to read: "CONSTRUCTION DETAILS". ITEM AD1-L5 Sheet LS502 – Planting Plan North Revise SHEET TITLE to read: "CONSTRUCTION DETAILS". Revise a portion of SHEET LS502 - CONSTRUCTION DETAILS, to include new detail A3 per SKL-002 attached to this addendum. ITEM AD1-L6 Sheet LS503 – Planting Plan North Revise SHEET TITLE to read: "CONSTRUCTION DETAILS". Revise a portion of SHEET LS503 - CONSTRUCTION DETAILS, to include new detail C2 per SKL-003 attached to this addendum. ARCHITECTURAL ITEMS PROJECT MANUAL ITEM AD1-A1 Section 01 30 00 – Administrative Requirements Page 01 30 00, page 3, replace section 3.06 with section 3.06 below: 3.06 CONSTRUCTION DOCUMENTS
A. The Owner distributes Bidding Documents and issues Addenda for securing Bids for the project Work. The Owner will provide to the Contractor 1 hard copy set of the Contract Documents. The Contractor shall pay the printing costs for additional sets.
ITEM AD1-A2 Section 01 30 00 – Administrative Requirements Page 01 30 00, page 5, section 3.13 replace paragraph “G” with paragraph “G” below:
G. Contractor must submit packaged roof top unit submittal and electrical lighting submittal for A/E team and Owner’s energy conservation contractor review and approval within the first group of submittals. For these submittals allow for 45 days for review time. Do not proceed with equipment ordering until approvals from A/E team and ECI have been received. For all other submittal reviews, allow 15 days excluding delivery time to and from the General Contractor.
ITEM AD1-A3 Section 10 22 27 – Operable Partitions Delete section 10 22 27 in the project manual and replace with section 10 22 27, dated 8/22/2017 attached to this addendum.
CITY OF FARMINGTON
800 Municipal Drive Farmington, NM 87401-2663
(505) 599-1373 Fax (505) 599-1377
http://www.fmtn.org
AD1-3
ARCHITECTURAL SHEETS ITEM AD1-A4 Sheet ADS101 – Demolition Site Plan Replace Tree Protection Notes legend with Tree Protection Legend on sheet ADD-1-01, dated 8/23/17 attached to this addendum. ITEM AD1-A5 Sheet AS101 – New Site Plan & Phasing Descriptions Add the following tree protection note to the Tree Protection Notes legend: 7. CONTRACTOR SHALL PROVIDE TEMPORARY WATER TO TREES, SHRUBS AND TURFGRASS SHOWN TO REMAIN, AS IS REQUIRED IN ORDER TO MAINTAIN ALL PLANT MATERIAL IN A HEALTHY, THRIVING AND DISEASE-FREE CONDITION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE FREQUENCY AND DURATION OF WATERING." ITEM AD1-A6 Sheet AS501 – Details – Site Delete keynote legend box, no keyed notes are used for this sheet. ITEM AD1-A7 Sheet A505 – Details – Casework Delete general notes -details legend box, no general notes are used for this sheet. MECHANICAL ITEMS DRAWING SHEETS ITEM ADD1-M1 Sheet M601 – MECHANICAL DETAILS
1. Revise rooftop unit schedule to provide direct drive ECM motors in lieu of belt drive with VFD. Units to be a minimum of 17 SEER.
ELECTRICAL ITEMS ELECTRICAL SHEETS ITEM ADD1-E1 Sheet EDL103 – Electrical Lighting Demo Plan – Theater Ground Floor
1. Revise existing seat junction box layout. 2. Revise keyed note 26.57 to read “LOCATION OF EXISTING FLOOR MOUNTED
JUNCTION BOX UNDER SEAT. MANY ARE DAMAGED OR NOT ENTIRELY RECESSED IN CONCRETE. SOME WILL BE REUSED FOR POWER SUPPLIES FOR NEW AISLE LIGHTING (SEE NEW PLAN, SHEET EL104). REMOVE EXISTING BOXES AND MC CABLE UNDER SEATS IN ALL LOCATIONS. IN LOCATIONS BEING REUSED, PROVIDE NEW BOX AND WIRING TO POWER SUPPLY. IN LOCATIONS NOT BEING REUSED, CAP WIRING AND COVER BOX WITH BLANK PLATE.”
3. Replace sheet with sheet EDL103 attached to this addendum.
CITY OF FARMINGTON
800 Municipal Drive Farmington, NM 87401-2663
(505) 599-1373 Fax (505) 599-1377
http://www.fmtn.org
AD1-4
ITEM ADD1-E2 Sheet ES101-Electrical Site Plan
1. Add outline and keyed notes related to splash pad bonding and minimum distance of other underground electrical.
2. Revise keyed note 26.94 to read: “EXISTING TREE SCULPTURE TO BE RELOCATED HERE. SCULPTURE ORIGINALLY HAD INTERNAL FLUORESCENT LIGHTING. IN THIS PROJECT, REPLACE INTERNAL FIXTURE WITH NEW LED AND RECONNECT. FOR BIDDING PURPOSES, INCLUDE AN ALLOWANCE OF $1000 TO COVER LABOR AND MATERIALS FOR THIS FIXTURE.”
3. Add missing type tags to fixture Z in alternate plan. 4. Replace sheet with sheet ES101 attached to this addendum.
ITEM ADD1-E3 Sheets EL101 – EL105 Electrical Lighting Plans
1. Correction to lighting control scenario schedule: LC.04 description should read “manual switching,” not “manual dimming.”
2. Replace sheets with sheets EL101 – EL 105 attached to this addendum. ITEM ADD1-E4 Sheet EL101 – Electrical Lighting Plan – Exhibit Hall
1. Add missing type tags for exit signs. 2. Add note indicating existing exhibit hall controls to be combined where partition wall is
being removed. 3. Replace sheet with sheet EL101 attached to this addendum.
ITEM ADD1-E5 Sheet EL102 - Electrical Lighting Plan – Exhibit Hall Addition
1. Add lighting control zoning details for exhibit hall. 2. Replace sheet with sheet EL102 attached to this addendum.
ITEM ADD1-E6 Sheet EL103 - Electrical Lighting Plan – Theater Basement
1. Remove duplicate fixture shown in elevator area. 2. Replace sheet with sheet EL103 attached to this addendum.
ITEM ADD1-E7 Sheet EL104 - Electrical Lighting Plan – Theater Ground Floor
1. Revise theater floor level lighting plan. 2. Replace sheet with sheet EL104 attached to this addendum.
ITEM ADD1-E8 Sheet EP105 – Elec Power & Special Systems Plan – Theater Mezzanine
1. Add ceiling receptacle in control booth for added security camera. 2. Replace sheet with sheet EP105 attached to this addendum.
CITY OF FARMINGTON
800 Municipal Drive Farmington, NM 87401-2663
(505) 599-1373 Fax (505) 599-1377
http://www.fmtn.org
AD1-5
ITEM ADD1-E9 Sheet E503 – Lighting Control Details & Schedules
1. Revise exhibit hall lighting control one-line diagram. 2. Replace sheet with sheet E503 attached to this addendum.
ITEM ADD1-E10 Sheet E504 – Electrical Details
1. Add splash pad grounding and bonding detail. 2. Replace sheet with sheet E504 attached to this addendum.
ITEM ADD1-E11 Sheet E601 – Light Fixture Schedule
1. Fill in pre-approved alternate fixture specification columns where applicable. 2. Revise specification for theater aisle fixtures (Q, R, and S types). 3. Clarification: amount of allowance for type D fixture can be found in specification section
01 21 00-1.06, Allowances Schedule. 4. Replace sheet with sheet E601 attached to this addendum.
END OF ADDENDUM NO. 1
Jennifer Rowland, CPPB Buyer II Phone: (505) 599-1386 Fax: (505) 599-1377 Email: [email protected]
FCC Renovation & Expansion G/S SJCF Arch 5164.00
OPERABLE PARTITIONS 10 22 27 - 1 8/22/2017
SECTION 10 22 27OPERABLE PARTITIONS
PART 1: GENERAL1.01 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract including General and Supplementary Conditions and Division1 Specification Sections, apply to this Section.
1.02 SUMMARYA. This Section includes the following:
1. Electrically operated, continuously hinged partitions.B. Related Sections include the following:
1. Division 3 Sections for concrete tolerances required.2. Division 5 Sections for primary structural support, including pre-punching of support members by
structural steel supplier per operable partition supplier's template.3. Division 6 Sections for wood framing and supports, and all blocking at head and jambs as required.4. Division 9 Sections for wall and ceiling framing at head and jambs.
1.03 QUALITY ASSURANCEA. Installer Qualifications: An experienced installer who is certified in writing by the operable partition
manufacturer, as qualified to install the manufacturer's partition systems for work similar in material, design, andextent to that indicated for this Project.
B. Acoustical Performance: Test operable partitions in an independent acoustical laboratory in accordance withASTM E90 test procedure to attain no less than the STC rating specified. Provide a complete and uneditedwritten test report by the testing laboratory upon request.
C. Preparation of the opening shall conform to the criteria set forth per ASTM E557 "Standard Practice forArchitectural Application and Installation of Operable Partitions."
1.04 SUBMITTALSA. Product Data: Material descriptions, construction details, finishes, installation details, and operating instructions
for each type of operable partition, component, and accessory specified.B. Shop Drawings: Show location and extent of operable partitions. Include plans, sections, details, attachments to
other construction, and accessories. Indicate dimensions, weights, conditions at openings, and at storage areas,and required installation, storage, and operating clearances. Indicate location and installation requirements forhardware and track, including floor tolerances required and direction of travel. Indicate blocking to be providedby others.
C. Setting Drawings: Show imbedded items and cutouts required in other work, including support beam punchingtemplate.
D. Samples: Color samples demonstrating full range of finishes available by architect. Verification samples will beavailable in same thickness and material indicated for the work.
1.05 DELIVERY, STORAGE, AND HANDLINGA. Clearly mark packages and panels with numbering systems used on Shop Drawings. Do not use permanent
markings on panels.B. Protect panels during delivery, storage, and handling to comply with manufacturer's direction and as required to
prevent damage.1.06 WARRANTY
A. Provide written warranty by manufacturer of operable partitions agreeing to repair or replace any componentswith manufacturing defects.
B. Partition Warranty period: Three (3) years from date of shipment.C. Suspension System Warranty:
FCC Renovation & Expansion G/S SJCF Arch 5164.00
OPERABLE PARTITIONS 10 22 27 - 2 8/22/2017
1. OP-01: Ten (10) years from date of shipment.2. OP-02: Ten (10) years from date of shipment.3. OP-03: Ten (10) years from date of shipment.
PART 2 - PRODUCTS2.01 MANUFACTURERS, PRODUCTS, AND OPERATIONS
A. Manufacturers: Subject to compliance with requirements, provide products by the following:1. Modernfold, Inc.2. Products: Subject to compliance with the requirements, provide the following product:
a. OP-01: Acousti-Seal Encore - Automatic Panel: Electrically operated continuously hinged operablepartition.
b. OP-02: Acousti-Seal Encore - Automatic Panel: Electrically operated continuously hinged operablepartition.
c. OP-03: Acousti-Seal Encore - Automatic Panel: Electrically operated continuously hinged operablepartition.
2.02 OPERATIONA. OP-01: Acousti-Seal Encore - Series of continuously hinged flat panels, electrically operated, top supported with
operable floor seals and automatic top seals.B. OP-02: Acousti-Seal Encore - Series of continuously hinged flat panels, electrically operated, top supported with
operable floor seals and automatic top seals.C. OP-03: Acousti-Seal Encore - Series of continuously hinged flat panels, electrically operated, top supported with
operable floor seals and automatic top seals.2.03 Final Closure:
A. OP-01: Partition shall be operated by two push button control stations wired in series and located on oppositesides of the partition. Control stations shall be activated by key switch at stack end of partition. Motor unit shallbe reversible, continuous duty, and class A insulated. Motor unit shall have NEMA MG1 service factor, highstarting torque, thermal overload protection, and open/drip proof enclosure. Motor assembly shall have wiringcompliant with NFPA 70, 24 volt controls, compliant with UL508A, and speed of 28 feet/minute. The drive unitmotor shall be equipped with outboard limit switches to prevent over-extension. A positive-chain drive attachedto the lead panel shall pull the partition across the opening. Cable, belt or other friction type drives will not beaccepted.
B. OP-02: Partition shall be operated by two push button control stations wired in series and located on oppositesides of the partition. Control stations shall be activated by key switch at stack end of partition. Motor unit shallbe reversible, continuous duty, and class A insulated. Motor unit shall have NEMA MG1 service factor, highstarting torque, thermal overload protection, and open/drip proof enclosure. Motor assembly shall have wiringcompliant with NFPA 70, 24 volt controls, compliant with UL508A, and speed of 28 feet/minute. The drive unitmotor shall be equipped with outboard limit switches to prevent over-extension. A positive-chain drive attachedto the lead panel shall pull the partition across the opening. Cable, belt or other friction type drives will not beaccepted.
C. OP-03: Partition shall be operated by two push button control stations wired in series and located on oppositesides of the partition. Control stations shall be activated by key switch at stack end of partition. Motor unit shallbe reversible, continuous duty, and class A insulated. Motor unit shall have NEMA MG1 service factor, highstarting torque, thermal overload protection, and open/drip proof enclosure. Motor assembly shall have wiringcompliant with NFPA 70, 24 volt controls, compliant with UL508A, and speed of 28 feet/minute. The drive unitmotor shall be equipped with outboard limit switches to prevent over-extension. A positive-chain drive attachedto the lead panel shall pull the partition across the opening. Cable, belt or other friction type drives will not beaccepted.
D. Electric motor shall consist of:1. OP-01: A 480-volt, 3-phase2. OP-02: A 480-volt, 3-phase3. OP-03: A 480-volt, 3-phase
FCC Renovation & Expansion G/S SJCF Arch 5164.00
OPERABLE PARTITIONS 10 22 27 - 3 8/22/2017
2.04 PANEL CONSTRUCTIONA. Nominal 4.25-inch (108mm) thick panels in manufacturer's standard 51-inch (1295mm) widths. All panel
horizontal and vertical framing members fabricated from minimum 16-gage formed steel with overlapped andwelded corners for rigidity. Top channel is reinforced to support suspension system components. Frame isdesigned so that full vertical edges of panels are of formed steel and provide concealed protection of the edges ofthe panel skin.
B. Panel skin shall be:1. OP-01: Acoustical, non-woven needle punch carpet, with fused fibers to prevent unraveling or fray of
material. Acoustical ratings of panels with this construction minimum:a. 52 STC
2. OP-02: Acoustical, non-woven needle punch carpet, with fused fibers to prevent unraveling or fray ofmaterial. Acoustical ratings of panels with this construction minimum:a. a. 52 STC
3. 3. OP-03: Acoustical, non-woven needle punch carpet, with fused fibers to prevent unraveling or fray ofmaterial. Acoustical ratings of panels with this construction minimum:a. a. 52 STC
4. Hinges for Panels, Closure Panels, Pass Doors, and Pocket Doors shall be:a. OP-01: Full leaf butt hinges, attached directly to the panel frame with welded hinge anchor plates
within panel to further support hinge mounting to frame. Lifetime warranty on hinges. Hingesmounted into panel edge or vertical astragal are not acceptable.
b. OP-02: Full leaf butt hinges, attached directly to the panel frame with welded hinge anchor plateswithin panel to further support hinge mounting to frame. Lifetime warranty on hinges. Hingesmounted into panel edge or vertical astragal are not acceptable.
c. OP-03: Full leaf butt hinges, attached directly to the panel frame with welded hinge anchor plateswithin panel to further support hinge mounting to frame. Lifetime warranty on hinges. Hingesmounted into panel edge or vertical astragal are not acceptable.
5. Panel Trim: No vertical trim required or allowed on edges of panels; minimal groove appearance at allpanel joints.
6. Panel Weights:a. OP-01: 52 STC - 8.2 lbs./square footb. OP-02: 52 STC - 8.2 lbs./square footc. OP-03: 52 STC - 8.2 lbs./square foot
2.05 PANEL FINISHA. Panel finish shall be factory applied, Class "A" rated material. Finish shall be:
1. OP-01: Acoustical, non-woven needle punch carpet, with fused fibers to prevent unraveling or fray ofmaterial: Color: Brocade 003.
2. OP-02: Acoustical, non-woven needle punch carpet, with fused fibers to prevent unraveling or fray ofmaterial: Color: Brocade 003.
3. OP-03: Acoustical, non-woven needle punch carpet, with fused fibers to prevent unraveling or fray ofmaterial: Color: Brocade 003.
4. Panel Trim: Exposed panel trim of one consistent color:a. OP-01: Smoke Gray SW6002b. OP-02: Smoke Gray SW6002c. OP-03: Smoke Gray SW6002
2.06 SOUND SEALSA. Vertical Interlocking Sound Seals between panels: Aluminum astragals, with tongue and groove configuration in
each panel edge. Rigid plastic astragals are not acceptable.B. Horizontal Top Seals shall be Modernfold SureSet™ automatic operable top seals, manually operated top seals
not required or permitted.C. Horizontal bottom floor seals shall be Modernfold Sureset™ bottom seal:
FCC Renovation & Expansion G/S SJCF Arch 5164.00
OPERABLE PARTITIONS 10 22 27 - 4 8/22/2017
1. OP-01: Modernfold SA2E Bottom Seal. Automatic bottom seals providing nominal 2-inch (51 mm)operating clearance with an operating range of +1/2-inch (13 mm) to -1-1/2-inch (38 mm) whichautomatically drop as panels are positioned and final closure made, without the need for tools or cranks.
2. OP-02: Modernfold SA2E Bottom Seal. Automatic bottom seals providing nominal 2-inch (51 mm)operating clearance with an operating range of +1/2-inch (13 mm) to -1-1/2-inch (38 mm) whichautomatically drop as panels are positioned and final closure made, without the need for tools or cranks.
3. OP-03: Modernfold SA2E Bottom Seal. Automatic bottom seals providing nominal 2-inch (51 mm)operating clearance with an operating range of +1/2-inch (13 mm) to -1-1/2-inch (38 mm) whichautomatically drop as panels are positioned and final closure made, without the need for tools or cranks.
2.07 SUSPENSION SYSTEMA. OP-01: #14 Suspension System
1. Suspension Tracks: Minimum 7-gauge, 0.18-inch (4.57mm) roll formed steel. Static loading of track withbrackets at 48-inch (1220mm) centers shall show no failure of track or brackets at 5,000 pounds (2550kg)point loading at mid-span. Track shall be supported by adjustable steel hanger brackets connected tostructural support pairs of 0.50-inch (13mm) diameter threaded rods. Brackets must support the loadbearing surface of the track.a. Exposed track soffit: Steel, removable for service and maintenance, attached to track bracket without
exposed fasteners, and pre-painted off-white.b. Carriers: All-steel trolleys with steel tired ball bearing wheels.
2. OP-02: #14 Suspension Systema. Suspension Tracks: Minimum 7-gauge, 0.18-inch (4.57mm) roll formed steel. Static loading of track
with brackets at 48-inch (1220mm) centers shall show no failure of track or brackets at 5,000 pounds(2550kg) point loading at mid-span. Track shall be supported by adjustable steel hanger bracketsconnected to structural support pairs of 0.50-inch (13mm) diameter threaded rods. Brackets mustsupport the load bearing surface of the track.1) Exposed track soffit: Steel, removable for service and maintenance, attached to track bracket
without exposed fasteners, and pre-painted off-white.b. 2. Carriers: All-steel trolleys with steel tired ball bearing wheels.
3. OP-03: #14 Suspension Systema. 1. Suspension Tracks: Minimum 7-gauge, 0.18-inch (4.57mm) roll formed steel. Static loading of
track with brackets at 48-inch (1220mm) centers shall show no failure of track or brackets at 5,000pounds (2550kg) point loading at mid-span. Track shall be supported by adjustable steel hangerbrackets connected to structural support pairs of 0.50-inch (13mm) diameter threaded rods. Bracketsmust support the load bearing surface of the track.1) Exposed track soffit: Steel, removable for service and maintenance, attached to track bracket
without exposed fasteners, and pre-painted off-white.b. Carriers: All-steel trolleys with steel tired ball bearing wheels.
2.08 OPTIONSA. Available accessories/options:
1. OP-01: Pocket Doors: Acousti-Seal Pocket Doors by Modernfold, Inc., with same construction as panels.Plastic laminate door fronts to match Nevamar Cognac Birdseye W8348V.a. Pocket Door configuration shall be manually operated: Type III double doors hinged to a jamb on
each side and closing in the center. One of the door panels is equipped with a smaller hinged panelthat folds back when the operable partition is extended into the pocket.
2. OP-02: Pocket Doors: Acousti-Seal Pocket Doors by Modernfold, Inc., with same construction as panels.Plastic laminate door fronts to match Nevamar Cognac Birdseye W8348V.a. Pocket Door configuration shall be manually operated: Type III double doors hinged to a jamb on
each side and closing in the center. One of the door panels is equipped with a smaller hinged panelthat folds back when the operable partition is extended into the pocket.
3. OP-03: Pocket Doors: Acousti-Seal Pocket Doors by Modernfold, Inc., with same construction as panels.Plastic laminate door fronts to match Nevamar Cognac Birdseye W8348V.
FCC Renovation & Expansion G/S SJCF Arch 5164.00
OPERABLE PARTITIONS 10 22 27 - 5 8/22/2017
a. Pocket Door configuration shall be manually operated: Type III double doors hinged to a jamb oneach side and closing in the center. One of the door panels is equipped with a smaller hinged panelthat folds back when the operable partition is extended into the pocket.
PART 3: EXECUTION3.01 INSTALLATION
A. General: Comply with ASTM E557, operable partition manufacturer's written installation instructions, Drawingsand approved Shop Drawings.
B. Install operable partitions and accessories after other finishing operations, including painting have beencompleted.
C. Match operable partitions by installing panels from marked packages in numbered sequence indicated on ShopDrawings.
D. Broken, cracked, chipped, deformed or unmatched panels are not acceptable.3.02 CLEANING AND PROTECTION
A. Clean partition surfaces upon completing installation of operable partitions to remove dust, dirt, adhesives, andother foreign materials according to manufacturer's written instructions.
B. Provide final protection and maintain conditions in a manner acceptable to the manufacturer and installer thatinsure operable partitions are without damage or deterioration at time of Substantial Completion.
3.03 ADJUSTINGA. Adjust operable partitions to operate smoothly, easily, and quietly, free from binding, warp, excessive deflection,
distortion, nonalignment, misplacement, disruption, or malfunction, throughout entire operational range.Lubricate hardware and other moving parts.
3.04 EXAMINATIONA. Examine flooring, structural support, and opening, with Installer present, for compliance with requirements for
installation tolerances and other conditions affecting performance of operable partitions. Proceed withinstallation only after unsatisfactory conditions have been corrected.
3.05 DEMONSTRATIONA. Demonstrate proper operation and maintenance procedures to Owner's representative.B. Provide Operation and Maintenance Manual to Owner's representative.
END OF SECTION
1. CONTRACTOR SHALL ESTABLISH A ROOT PROTECTION ZONE AROUND EACH EXISTING TREE TO REMAIN. THE ROOT PROTECTION ZONE SHALL BE AN AREA
DEFINED BY A RADIUS EXTENDING OUTWARD FROM THE TRUNK OF THE TREE A DISTANCE OF ONE LINEAR FOOT FOR EACH INCH DIAMETER OF THE TREE. THE
TREE DIAMETER SHALL BE MEASURED AT BREAST HEIGHT (4.5' ABOVE FINISH GRADE). EXAMPLE: A 10 INCH DIAMETER TREE WILL HAVE A 10 FOOT RADIUS
ROOT PROTECTION ZONE.
2. CONTRACTOR SHALL INSTALL FENCING AT THE PERIMETER OF ROOT PROTECTION ZONES. NO WORK SHALL BEGIN WHERE TREE PROTECTION FENCING HAS NOT BEEN COMPLETED AND APPROVED. TREE PROTECTION
FENCING SHALL BE INSTALLED, MAINTAINED AND REPAIRED BY THE CONTRACTOR DURING CONSTRUCTION. THE FENCING SHALL BE A MINIMUM OF
4' HEIGHT.
3. CONTRACTOR SHALL NOT STORE OR DRIVE EQUIPMENT, VEHICLES OR MATERIALS WITHIN THE ROOT PROTECTION ZONE.
4. CONTRACTOR SHALL PROTECT EXISTING ROOTS FROM DAMAGE WHEN WORKING WITHIN THE ROOT PROTECTION ZONE. THE CONTRACTOR SHALL
LIMIT DEMOLITION OR OTHER CONSTRUCTION ACTIVITIES WITHIN THE ROOT PROTECTION ZONE TO THE MINIMUM DISTURBANCE REQUIRED TO COMPLETE
CONSTRUCTION.
5. CONTRACTOR SHALL NOT ALLOW CONCRETE TRUCKS TO CLEAN CHUTES OR DUMP EXCESS CONCRETE OR ANY OTHER CEMENTITIOUS PRODUCTS IN ANY PORTION OF THE SITE. CONTRACTOR SHALL CLEAN THE WASTE OF OTHER
CEMENTITIOUS MATERIALS FROM THE SURFACE AND THEY SHALL NOT BE TURNED UNDER DURING FINAL GRADING.
6. CONTRACTOR SHALL NOT TRENCH WITHIN THE DRIPLINE OF EXISTING TREES.
AT LOCATIONS WHERE IT IS NECESSARY TO INSTALL LINES OR WIRE WITHIN THE DRIPLINE OF EXISTING TREES, THE UTILITY SHALL BE INSTALLED BY BORING UNDER TREE ROOTS.
7. CONTRACTOR SHALL PROVIDE TEMPORARY WATER TO TREES, SHRUBS AND
TURFGRASS SHOWN TO REMAIN, AS IS REQUIRED IN ORDER TO MAINTAIN ALL PLANT MATERIAL IN A HEALTHY, THRIVING AND DISEASE-FREE CONDITION.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE FREQUENCY AND DURATION OF WATERING."
DATE
PAGE
JOB NO.
C:\
Use
rs\s
mez
a.M
AIN
\Do
cum
ents
\FC
C E
xpan
sio
n_R
17_s
mez
a.rv
t8/
24/2
017
10:1
6:53
AM
5264.00 08/23/17
FARMINGTON CIVIC CENTER RENOVATIONS &
EXPANSION
CITY OF FARMINGTON ADD-01
TREE PROTECTION NOTES
-01
3
33
3
3
K
3
3
3 3
3
3
3
3
3
.14
J
J
J
J J
J
J J
J J
J
J
J
J
J
J
JJ
J
J
J
J
J
J
J JJ
J
J
J
X76.2
X76.2
X74.J
X74.J
X74.J
X74.J
X74.J
X74.J
X74.J
X74.J
X74.HX74.H
X74.H
X74.HX74.HX74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H
X74.H X74.H
X74.H
X74.H
X74.RX74.RX74.R
X74.GX74.J
X74.JX74.B1
X74.B1
X74.A1
X74.A1
X74.A1
X74.A1X74.A1
X74.A1X74.A1
X74.A1
X74.B1
X74.B1
X74.JX74.J
X74.A1
X74.A1
X74.G
X74.R
X74.R
X74.R
X74.J X74.J
X74.J X74.J
X74.J X74.J
X76.EX
X74.EM
X74.EM
X74.J
X74.J
X76.EX
X76.EX
X76.1X76.1 X76.1
X76.1X76.1 X76.1
X76.1X76.1 X76.1
X76.1X76.1 X76.1
X74.JX76.1 X76.1
X76.1 X76.1
X76.1 X76.1
X76.1 X76.1
X76.1
X74.ZX74.Z X74.Z
X74.Z
X74.Z X74.Z
X74.Z X74.Z
X74.Z X74.Z
X74.Z X74.Z
X74.Z X74.Z
X74.Z X74.Z
X76.1X76.EX
X76.1 X76.1 X76.1 X76.1
X76.1
X76.1
X76.1
X76.1
X76.1
X76.1
X76.1
X76.1
X76.1
X76.1
X76.1
X76.1
X76.1
X76.1
X76.1 X76.1
X76.1
X76.1
X76.EX
X76.EXX76.1 X76.1
X74.B1
X74.B1
X74.B1
X74.B1
X74.B1
X74.B1
X74.B1 X74.B1 X74.B1 X74.B1
X74.B1
X74.B1
X74.B1
X74.B1
X74.B1
X74.B1
X76.EX
X76.EX
X74.Z
X74.Z
X74.ZX74.Z
X74.Z
X74.Z
X74.B1
VESTT101
WOMENT103
MENT113
WOMEN'S DRESST123
WOMENT124
MEN'S DRESST126
MENT127
BOARD RMT122
MAKE-UPT125
STAGET116
AUDITORIUMT115
JANT114
JANT104
PRIVATE DRESST121
PRIVATE DRESST120
JANT119
PRIVATE DRESST118
VESTT128
CORRIDORT117
S STAIRT105
W STAIRT112
??
LOBBYT100
CORRIDORT102
STORAGE 1T109
TECHNICALT110
SUPERVISORST108
STORAGE 2T107
OFFICE 3T106
X74.PX74.PX74.PX74.PX74.P
X74.P
X74.P
X74.P
X74.P
X74.P
X74.P
26.43
X74.Z
X74.Z
X74.Z
X74.Z
X74.Z
X74.Z
X74.Z
X74.Z
X74.Z
X74.Z X74.Z X74.Z X74.Z X74.ZX74.Z
X74.Z
X74.Z
PANEL LAA
PANEL LAB
PANEL LAC
XW
PANEL W
PANEL LAF
26.5726.57
26.5726.57
26.57
26.57 26.57 26.57
26.57
26.57
26.57
26.57
26.57
26.57
26.57
26.57
26.57
26.57
26.57
26.57
26.57
26.57
26.57
26.57
26.57
26.57
26.57
26.57
26.57
X74.KA
X74.KA
X74.KA
X74.KAX74.KAX74.KA
X74.KA
X74.KA
X74.KA
X74.KA
X74.KA
X74.KA
26.57
IN HALL BELOW
IN HALL BELOW
IN HALL BELOW
IN HALL BELOW
463
TUR
NE R
DR
, SU
ITE
104A
DU
RAN
GO
, CO
813
03PH
ON
E : 9
70-3
8 5-1
570
FAX:
970
-385
-156
9
ME C
HAN
ICAL
, ELE
CTR
ICA L
& EN
V IR
ON
ME N
TAL
ENG
INEE
RIN
G IN
C.
A
B
C
D
E
A
B
C
D
E
1 2 3 4 5 6
DRAWN BY:
CHECKED BY:
PROJECT NO:
GREER-STAFFORD/SJCF, INC.C
SHEET TITLE
DRAWING SHEET
ISSU
E:
THIS DRAWING IS INCOMPLETE AND NOT TO BE USED FOR CONSTRUCTION UNLESS IT IS STAMPED, SIGNED, AND DATED BELOW
1 2 3 4 5 6
2017-07-20
8/22/2
017 7
:38:31
PM
C:\U
sers\
ambe
r\Doc
umen
ts\15
13_C
OF_C
ivic_
R17_
ambe
r.rvt
EDL103
ELEC. LIGHTINGDEMOLITION PLAN -THEATER - GROUNDFLOOR
1513
6/26
/201
7
FARM
ING
TON
CIV
IC C
ENTE
R R
ENO
VATI
ON
S &
EXPA
NSIO
N
200
W.
ARRIN
GTO
N,
FARM
ING
TON
, N
M 8
7401
CIT
Y O
F FA
RM
ING
TON
NB/AW
AW
N 1/8" = 1'-0"
ELECTRICAL LIGHTING DEMOLITION PLAN - THEATER - GROUND FLOORA1
KEYED NOTES26.43
REMOVE KEYED SWITCHES CONTROLLING TRACK LIGHTING. PER SIGN ON WALL, SWITCHBANK IN OFFICE ALSO CONTROLS TRACK LIGHTING (VERIFY). SEE CENTRAL LIGHTINGCONTROL DETAIL ON SHEET E503 FOR NEW CONTROL SYSTEM.
26.57
LOCATION OF EXISTING FLOOR MOUNTED JUNCTION BOX UNDER SEAT. MANY AREDAMAGED OR NOT ENTIRELY RECESED IN CONCRETE. SOME WILL BE REUSED FOR POWERSUPPLIES FOR NEW AISLE LIGHTING (SEE NEW PLAN, SHEET EL104). REMOVE EXISTINGBOXES AND MC CABLE UNDER SEATS IN ALL LOCATIONS. IN LOCATIONS BEING REUSED,PROVIDE NEW BOX AND WIRING TO POWER SUPPLY. IN LOCATIONS NOT BEING REUSED,CAP WIRING AND COVER BOX WITH BLANK PLATE.
GENERAL ELEC DEMO NOTES1
REFER TO THEATER SYSTEMS DEMOLITION (TDS) AND AUDIO-VISUAL DEMOLITION (AVD)SHEETS FOR ADDITIONAL DEMOLITION WORK BY ELECTRICAL CONTRACTOR. COORDINATEWITH THEATER CONTRACTOR FOR DEMOLITION OBSERVATION WHERE APPLICABLE.
Mar
kD
ate
Des
crip
tion
18/
24/1
7AD
DEN
DU
M 1
N 1/8" = 1'-0"
ELECTRICAL LIGHTING DEMOLITION PLAN - THEATER - FLOOR LEVEL1
1
1
LA PLATA STREET
WEST ARRINGTON STREET
BEHRE
ND
AVE
NOR
TH ALLEN
AVE
E
RL
RL
RL
RL
RL
RL
RL
RG
RG
RG
RG
RG
RV
RG
RG
JR
L
RL
RL
RL
J
RF
RF
RF RP RF RP RF RP
RP
RF
RP
RF
RP
RP
RP
RFRP
RF
RP
RP
RP
RFRP
LC.09
J
J
RGRL
RL
RL
RL
RL
RG
RG
RG
RG
RG
RG
RG
RG
RG
RG
RG
RG
RG
RL
RL
RG
JJJ
J
N
J
RG
RG
RL
RL
RL
RL
RP
RF
RP
RF
RP
RP
RFRP
RF
RP
RP
RP
LC.09
J
RG
RG
RG
RG
RG
RG
RL
RL
RG
J
N
J
RF
RG
RL
RP
RV
NEW XFMR"T1" (STEP-UP)
SERVICE #2TRANSFORMER(EXISTING TO
REMAIN)
PANEL MDP2
SERVICE # 1TRANSFORMER
26.15
PANEL LAF
26.21
26.19
SERVICE #1DISCONNECT
26.39
PB
PB
PB
PB
P2
P2
P2 P2 P2
P2
P4
P4
P2
P4
P4
P4
P2
P2
P2
P2
P2
P2
PB
PB
PB
PB
PBPB
PB
PB
PB
PB
PB
PB
26.20TYPTYP
26.21TYP
26.41
26.42
26.4926.49
Z
Z
Z
Z
26.50
26.26
FP
CS3
26.24
X-CH1
X-CH2XFMRSECONDARYDISCONNECT
EXIST. UGE TO REMAIN
NEW UGE
NEW UGE
NEW
UGE
26.55
D - 10D - 4
D - 4LAF - 1,3,5
LAF - 8
D - 6 D - 12
D - 6 D - 12
D - 1,3,5
D - 10D - 2
D - 12D - 6
D - 6 D - 8D - 1,3,5
D - 6 D - 8
D - 1,3,5 D - 2
D - 14D - 2
D - 1,3,5 D - 2
D - 14
D - 2
LAF - 1,3,5
LAF - 8
LAF - 8
LAF - 1,3,5
LAF - 1,3,5LAF - 8
LAF - 22LAF - 6 LAF - 6
LAF - 18
LAF - 8
LAF - 10 LAF - 7,9,11
LAF - 24 LAF - 10
LAF - 10LAF - 24
LAF - 24 LAF - 10LAF - 18LAF - 10
LAF - 20 LAF - 10
LAF - 10LAF - 20
LAF - 16 LAF - 10
LAF - 10LAF - 16
LAF - 7,9,11 LAF - 10
D - 10D - 2
LAF - 22LAF - 6
LAF - 22
D - 11,13
LAF - 25,27
LAF - 33,35
D - 11,13
D - 11,13
D - 11,13
D - 7,9
D - 19
D - 19
D - 19
D - 19
LAF - 25,27
LAF - 25,27
LAF - 25,27
LAF - 33,35
LAF - 25,27 LAF - 25,27 LAF - 25,27
LAF - 25,27
LAF - 29,31
LAF - 29,31
LAF - 29,31
LAF - 29,31
LAF - 33,35
LAF - 33,35D - 7,9
D - 11,13
D - 11,13
D - 11,13
D - 11,13
D - 7,9
LAF - 33,35
LAF - 29,31
LAF - 29,31
D - 7,9
D - 7,9D - 7,9
D - 7,9
LAF - 2
LAF - 19,21,23
HPA - 7,9,11
HPA - 1,3,5
D - 16
LAF - 12
LAF - 14
D - 18D - 20D - 22
26.23
YYD - 11,13D - 11,13
PANEL D
THEATER
EXHIBIT HALL
EXHIBIT HALLADDITION
26.88
26.90
26.90
26.94
26.22
26.18
5'SPLASH PAD
26.25
1
26.42
NOTE:
THIS PLAN SHOWS CHANGES TO THE SITE LAYOUT IN THE TRELLIS STRUCTURE ALTERNATE. FIXTURES OUTSIDE THIS PLAN DO NOT CHANGE.
26.23
26.23
26.23
Y Y Y
Y Y YYY
YY
Y
YY
YYY
Y
Y
Y
PB
PB
P2
P4
P4
P4
P4
P4
P2
P2
PB
PB
PB
PB
PB
26.4926.49
PB
YYLAF - 37,39LAF - 37,39LAF - 37,39LAF - 37,39LAF - 37,39LAF - 37,39LAF - 37,39
LAF - 37,39LAF - 37,39
LAF - 37,39
LAF - 37,39 LAF - 37,39
D - 15,17D - 15,17D - 15,17
TYP.
TYP.
D - 15,17TYP. ALL FIXTURES IN THIS STRUCTURE
Z
Z
Z
Z
26.94
5'SPLASH PAD
1
26.25
26.42
DESCRIPTION
HOLIDAY LIGHTING RECEPTACLE BOX. ANGLED FACE FOR LONG TERM USE. PROVIDE PERMANENT WEATHERPROOF LABEL INSIDE COVER, READING "HOLIDAY LIGHTING ONLY".
GENERAL POWER RECEPTACLE BOX, WITH TWO 20 AMP RECEPTACLES. PROVIDE PERMANENT WEATHERPROOF LABEL INSIDE COVER WITH CIRCUIT NUMBER.
FOOD VENDOR AND GENERAL POWER RECEPTACLE BOX, WITH ONE 50 AMP AND TWO 20 AMP RECEPTACLES.
RV PEDESTAL FOR TOURING COMPANIES. COORDNINATE EXACT LOCATION WITH LANDSCAPE CONTRACTOR.
POLE RECEPTACLE INCLUDED WITH LIGHT POLE. ALSO FOR HOLIDAY LIGHTING USE, SIMILAR TO TYPE RL.
SPECIFICATION
MIDWEST ELECTRICU010SEPGRPGREEN FINISH
MIDWEST ELECTRICU012010GRPGREEN FINISH
MIDWEST ELECTRICU076GWHITE FINISH
MIDWEST ELECTRICU075CP6010GRAY FINISH
REPLACE COVER PROVIDED WITH METAL HEAVY DUTY WHILE-IN-USE COVER (WHITE FINISH).
COMPONENTS INCLUDED
(1) 5-20R, GFCI, TAMPERPROOF
(2) 5-20R, GFCI, TAMPERPROOF
(2) 5-20R, GFCI, TAMPERPROOF(1) 14-50R
(3) CIRCUIT BREAKERS
(1) 5-20R, GFCI, TAMPERPROOF(1) 7-30R(1) 14-50R
(3) CIRCUIT BREAKERS
(1) 5-20R, GFCIINCLUDED WITH POLE
CONTROLS
ROUTE EACH CIRCUIT THROUGH POWERPACK FOR PHOTOCELL CONTROL BY CENTRAL LIGHTING CONTROL SYSTEM. SEE SHEET E503.
NONE
NONE
NONE
SAME AS TYPE RL
PLAN SYMBOL
SITE RECEPTACLE SCHEDULEMOUNTING
UNISTRUT4' AFG
UNISTRUT4' AFG
LIGHT POLE BASESEE DETAIL, SHEET E504
INTEGRAL POST
INTEGRAL TO LIGHT POLE
463
TUR
NE R
DR
, SU
ITE
104A
DU
RAN
GO
, CO
813
03PH
ON
E : 9
70-3
8 5-1
570
FAX:
970
-385
-156
9
ME C
HAN
ICAL
, ELE
CTR
ICA L
& EN
V IR
ON
ME N
TAL
ENG
INEE
RIN
G IN
C.
A
B
C
D
E
A
B
C
D
E
1 2 3 4 5 6
DRAWN BY:
CHECKED BY:
PROJECT NO:
GREER-STAFFORD/SJCF, INC.C
SHEET TITLE
DRAWING SHEET
ISSU
E:
THIS DRAWING IS INCOMPLETE AND NOT TO BE USED FOR CONSTRUCTION UNLESS IT IS STAMPED, SIGNED, AND DATED BELOW
1 2 3 4 5 6
2017-07-20
8/22/2
017 7
:29:40
PM
C:\U
sers\
ambe
r\Doc
umen
ts\15
13_C
OF_C
ivic_
R17_
ambe
r.rvt
ES101
ELECTRICAL SITEPLAN
1513
6/26
/201
7
FARM
ING
TON
CIV
IC C
ENTE
R R
ENO
VATI
ON
S &
EXPA
NSIO
N
200
W.
ARRIN
GTO
N,
FARM
ING
TON
, N
M 8
7401
CIT
Y O
F FA
RM
ING
TON
AW/NB
AW
N 1" = 20'-0"
ELECTRICAL SITE PLAN - BASE BIDA1 N 1" = 20'-0"
ELECTRICAL SITE PLAN - TRELLIS ALTERNATEA4
KEYED NOTES26.15
PROVIDE NEW "COMPANY SWITCH" CAM-LOCK CONNECTION POINT FOR OUTDOOR CONCERTS. REFER TO RISERDIAGRAM AND FEEDER SCHEDULE FOR DETAILED REQUIREMENTS. MOUNT ON UNISTRUT RACK, COORDINATE WITHLANDSCAPING CONTRACTOR FOR EXACT LOCATION, AND ENSURE THAT ANY SCREENING MAINTAINS NEC REQUIREDWORKING SPACE.
26.18LOCATION FOR EXTERIOR LIGHT CONTROL SWITCH STATION. PROVIDE LOCKING WEATHERPROOF COVER. REFER TOCENTRAL CONTROL SYSTEM DETAIL, SHEET E503. COORDINATE EXACT LOCATION WITH A/V CONTRACTOR SO THATA/V AND LIGHT CONTROLS ARE NEATLY GROUPED.
26.19 PROVIDE POWER TO NEW IRRIGATION CONTROLLER.
26.20 ON LIGHT POLE STRUCTURE, PROVIDE RECEPTACLES INDICATED, PER RECEPTACLE SCHEDULE, THIS SHEET. REFERTO POLE BASE ELECTRICAL DETAIL, SHEET E504.
26.21 IN EACH TREE PLANTER, PROVIDE UNISTRUT PEDESTAL WITH TWO RECEPTACLE BOXES PER RECEPTACLESCHEDULE. COORDINATE WITH LANDSCAPE CONTRACTOR FOR EXACT LOCATION.
26.22 AUDIO EQUIPMENT ALSO LOCATED ON THIS WALL. COORDINATE WITH A/V CONTRACTOR FOR EXACT LOCATION.
26.23 MOUNT LINEAR FIXTURES ON SIDES OF TRELLIS BEAMS SUCH THAT FACE OF FIXTURE IS FLUSH WITH BOTTOM OFBEAM.
26.24 HIDE RECEPTACLES BEHIND LOW WALL. COORDINATE EXACT LOCATION WITH ARCHITECT.
26.25 DO NOT INSTALL ANY UNDERGROUND ELECTRICAL LINE WITHIN 5 FEET OF THE SPLASH PAD. REFER TO SPLASH PADGROUNDING AND BONDING DETAIL (SHEET E504) FOR ADDITIONAL REQUIREMENTS.
26.26 PROVIDE POWER FOR NEW HOTBOX.
26.39UNDER ALTERNATE BID #4, PROVIDE FOUR CIRCUITS TO NEW DIGITAL MARQUE. COORDINATE EXACT REQUIREMENTSWITH MARQUE INSTALLER. ALSO PROVIDE CAT6 CABLING AND PATHWAY FROM NEW DIGITAL DISPLAY BOARD TOADMINISTRATION OFFICE. COORDINATE EXACT TERMINATION POINT IN ADMINISTRATION OFFICE WITH OWNER PRIORTO ROUGH-IN.
26.41UNDER BASE BID, PROVIDE CONDUIT AND PULL STRING FOR FUTURE FOUNTAIN PUMP. UNDER ALTERNATE BID #3,PROVIDE CONNECTION FOR FOUNTAIN PUMP (LOCATED IN ABOVE GROUND EQUIPMENT ENCLOSURE). COORDINATEEXACT LOCATION WITH LANDSCAPING CONTRACTOR PRIOR TO ROUGH-IN.
26.42UNDER BASE BID, PROVIDE CONDUIT AND PULL STRING FOR FUTURE SPLASH PAD CONTROL BOLLARD AND CENTERJET WITH INTEGRAL LIGHT, AND TERMINATE IN BELOW-GRADE BOXES. UNDER ALTERNATE BID #3, CONNECTFOUNTAIN CONTROL BOLLARD AND CENTER JET INTEGRAL LIGHT TO SPLASH PAD CONTROL BOX PER LANDSCAPINGPLANS. REFER TO SPLASH PAD GROUNDING DETAIL ON SHEET E504.
26.49 THIS FIXTURE SERVES AS EMERGENCY EGRESS FOR THIS BUILDING EXIT. ROUTE POWER THROUGH MINI-INVERTERMOUNTED ABOVE ACCESSIBLE CEILING JUST INSIDE DOOR. SEE LIGHTING PLAN.
26.50 PROVIDE SOLAR POWERED FLAG LIGHT ON TOP OF RELOCATED FLAG POLE.
26.55 NEW 4" FIBER CONDUIT AND PULL STRING, 2" CONDUIT AND PULL STRING FOR TELEPHONE TWISTED PAIR CABLING,AND 2" SPARE CONDUIT AND PULL STRING. NEW FIBER AND TELEPHONE TERMINATION OUTSIDE SCOPE OF WORK.
26.88 PROVIDE NEW 2" CONDUIT AND PULL STRING FOR TELEPHONE.
26.90
THIS EQUIPMENT IS BEING REPLACED, OR A VFD ADDED TO IT, BY AN ENERGY MANAGEMENT CONTRACTOR (E.C.I.)UNDER SEPARATE CONTRACT WITH THE CITY. THIS WORK IS ANTICIPATED TO BE COMPLETED BEFORE THEBEGINNING OF CONSTRUCTION FOR THIS PROJECT. EQUIPMENT INFORMATION SHOWN HERE, AND ON EQUIPMENTCONNECTION SCHEDULE, IS PER E.C.I. AND COULD NOT BE VERIFIED DURING DESIGN. CONFIRM ELECTRICALREQUIREMENTS PRIOR TO RECONNECTING EQUIPMENT TO NEW PANELS, AND REPORT ANY DISCREPANCIES TOENGINEER FOR FURTHER INSTRUCTIONS.
26.94EXISTING TREE SCULPTURE TO BE RELOCATED HERE. SCULPTURE ORIGINALLY HAD INTERNAL FLUORESCENTLIGHTING. IN THIS PROJECT, REPLACE INTERNAL FIXTURE WITH NEW LED AND RECONNECT. FOR BIDDING PURPOSES,INCLUDE AN ALLOWANCE OF $1000 TO COVER LABOR AND MATERIALS FOR THIS FIXTURE.
GENERAL ELEC. SITE PLAN NOTES1 REFER TO POLE BASE ELECTRICAL DETAIL, SHEET E504, FOR WIRING AND GROUNDING WITHIN POLE BASES.
2 REFER TO SITE CIRCUIT CONDUCTOR SCHEDULE, SHEET E504, FOR WIRE SIZES REQUIRED TO MITIGATEVOLTAGE DROP ON EACH CIRCUIT.
3 SEE THEATER DRAWINGS, PERFORMANCE LIGHTING DRAWINGS, AND AUDIO-VISUAL SYSTEM DRAWINGS FORADDITIONAL ELECTRICAL REQUIREMENTS NOT SHOWN ON POWER OR LIGHTING SHEETS.
Mar
kD
ate
Des
crip
tion
18/
24/1
7AD
DEN
DU
M 1
1
1
1
S
S
S
S
S
S
S
S
S
S
DD
DD
3
3
3
D
D
DD D D
LC.06
LC.01
LC.01
LC.03
LC.03
LC.03
LC.03
LC.02LC.02
LC.02
LC.02
LC.04
LC.04
LC.04
LC.04
LC.04
LC.04LC.04
LC.04
LC.04
LC.04
LC.05
LC.05
LC.05
LC.04
LC.06
LC.06
LC.06
LC.06
LC.06
LC.06
LC.02
LC.02
LC.05
LC.04
LC.04
3
EL102A3EL102A3
J2
PANEL B
PANEL L
PANEL A
PANEL AC
PANEL MDP1
MECHE113
JANE120
RESTROOME119
VESTE117
WOMENE118
VESTE107
MENE108
STOR 2E103
ELECE102
TICKETSE104
RESTROOME136
WOMENE134
MENE133
STORAGE 1E131
SERVER RME132
ELECE124
OFFICE 1E138
OFFICE 2E139
RECEPE137
MEETING #1E106
KIT STORE116
KITCHENE114
ENTRYE100
CORRIDOR #2E101
STOR 5E125
STOR 4E122
CORRIDOR #1E105
MEETING #2E109
STORAGE 3E110
VESTE123
EXHIBIT HALL #1E121
STORAGE 1E131
STOR 5E125
CORR #3E135
EXHIBIT HALL #1E121
CORR #3E135
J3, a
J3, a
J3, a
J3, a
J3, a
J3, a
J3, b
J3, b
J3, b
J3, b
J3, b J3, b J3, b
J3, b
J3, b
G2 G2
G2G2
G2 G2E
G2 G2
G2G2
G2 G2
G2EG2
G2G2
G2 G2
G2G2
G2E
G2G2
G2
G2 G2 G2 G2
G2 G2 G2 G2
EX
ab
CLOSETE111
FREEZER(INTEGRAL LIGHTING)
G1G1G1
K
K
K
K
KE
K
KE
K K
KE
K
K KE
H2EH2
H2
H2
H2
H2 H2
H2H2
J2E
J2J2
J2 J2 J2E J2 J2E J2
J2
J2E
J2
J2E
J2
J2E F4
H2F4 F4 F4 J1E
J1 J1E J1 J1J1
F4 F4 F4
J1
J1
J1
J1E
J1
J1E
ab
J3, aJ3, bJ3, b
J3, b J3, b J3, a
J3, b J3, b J3, a
H2
H2
G1G1G1
G1
G1
G1
J1S
J3F
J2
J2E J2
J2 J2E
J2 J2
J2 J2
J2E
abJ3, bJ3, b
J3, a
J3, b
J3, a J3E, a
J3 J3
J3 J3
J3
J3
J3
J3
F2
F4 F4 F4
J1E
J1 J1J1
F4 F4 F4
J1J1
J1E
J1
J2
J2E
J2
J2E
J2E
J2
H2H2H2
H2H2H2EH2
H2H2H2
T
T
T
J1
INV-1
W
WE
W
WE
G1
G1
G1
G1 G1G1G1
G1
G1
G1
EXR
ER
26.56
H2
H2E
H2
EXR
26.7526.75
PANEL K
G1
X76.P
X76.P
X76.P
X76.P
X76.P
X76.P
X76.P
X76.P
X76.P
X76.P
X76.P
H1E
H1
H1
H1E
H1
H1
H2
H1
H1
H2E
H2
26.96
26.95
EXISTING CORRIDOR CKT
EXISTING STORAGE E131 LTG CKT
STORAGE 1E131
STOR 5E125
EXEX
EX
EX
EX
EX
EX EX
EXISTING CONTROLS FOR THESE TWO ROOM SECTIONS TO BE COMBINED BY
MODIFYING CONTROL PANEL PROGRAMMING.SEE SHEETS EL102 AND E503.
1
463
TUR
NE R
DR
, SU
ITE
104A
DU
RAN
GO
, CO
813
03PH
ON
E : 9
70-3
8 5-1
570
FAX:
970
-385
-156
9
ME C
HAN
ICAL
, ELE
CTR
ICA L
& EN
V IR
ON
ME N
TAL
ENG
INEE
RIN
G IN
C.
A
B
C
D
E
A
B
C
D
E
1 2 3 4 5 6
DRAWN BY:
CHECKED BY:
PROJECT NO:
GREER-STAFFORD/SJCF, INC.C
SHEET TITLE
DRAWING SHEET
ISSU
E:
THIS DRAWING IS INCOMPLETE AND NOT TO BE USED FOR CONSTRUCTION UNLESS IT IS STAMPED, SIGNED, AND DATED BELOW
1 2 3 4 5 6
2017-07-20
8/24/2
017 3
:08:30
PM
C:\U
sers\
ambe
r\Doc
umen
ts\15
13_C
OF_C
ivic_
R17_
ambe
r.rvt
EL101
ELECTRICALLIGHTING PLAN -EXHIBIT HALL
1513
6/26
/201
7
FARM
ING
TON
CIV
IC C
ENTE
R R
ENO
VATI
ON
S &
EXPA
NSIO
N
200
W.
ARRIN
GTO
N,
FARM
ING
TON
, N
M 8
7401
CIT
Y O
F FA
RM
ING
TON
AW/NB
AW
N 1/8" = 1'-0"
ELECTRICAL LIGHTING PLAN - EXHIBIT HALLA1
KEYED NOTES26.56 EXISTING LIGHTING TO BE RELOCATED AND RECONNECTED. COORDINATE EXACT
LOCATION WITH THEATRE SYSTEMS DRAWINGS.
26.75RECEPTACLES AND DATA FOR RECEPTION AREA REMODEL ARE PART OF ALTERNATE BID#4. NEW LIGHTING AND FIRE PROTECTION ARE PART OF BASE BID. IF ALTERNATE BID IS NOTTAKEN, CHANGE LIGHTING FROM TWO DIMMING ZONES TO A SINGLE DIMMING ZONE.
26.95 APPROXIMATE LOCATION FOR TOUCHSCREEN LIGHTING CONTROL STATION. COORDINATEEXACT LOCATION WITH OWNER. REFER TO LIGHTING CONTROL DETAIL ON SHEET E503.
26.96 APPROXIMATE LOCATION FOR CENTRAL LIGHTING CONTROL PANEL. COORDINATE EXACTLOCATION WITH OWNER. REFER TO LIGHTING CONTROL DETAIL ON SHEET E503.
NOTES:
1. All lighting control products shall be same manufacturer. Exceptions must be requested in writing.
2. Pre-approved manufacturers are Wattstopper, Eaton/Greengate, and Acuity/NLight. Others must be pre-approvedprior to bidding (see specifications for prior approval request deadline).
3. All occupancy sensors shall be dual technology, ceiling or corner mounted, unless noted otherwise below.
4. Occupancy sensor layout is not shown on drawings due to variation in sensing range between manufacturers.Where occupancy sensing is indicated for a space, provide quantity of sensors required for complete coverage (minoror major motion as indicated below) based on sensing range of the proposed product line. Provide device layout onfloorplan in submittal package.
LIGHTING CONTROL SCENARIO LEGEND
APPLIES TO DESCRIPTION COVERAGE CONTROLZONES
MANUALDIMMING
MANUALSWITCHING
OCCUPANCYSENSING
SCHEDULEDON/OFF
DAYLIGHTSENSING
LC.01 MEETING ROOMS CONTROL BY LOCAL DEVICES ONLY. PROVIDE ROOM CONTROLLER ABOVE ACCESSIBLE CEILING. SENSORCONTROL SHALL BE MANUAL ON / AUTO OFF.
MINORMOTION 2 Yes Yes Yes No No
LC.02 OFFICES, DRESSING ROOMS CONTROL BY LOCAL DEVICES ONLY. PROVIDE WALLBOX OCCUPANCY SENSOR WITH INTEGRAL MANUALDIMMING. SENSOR CONTROL SHALL BE AUTO ON / AUTO OFF.
MINORMOTION 1 Yes Yes Yes No No
LC.03 MULTI-OCCUPANTRESTROOMS
CONTROL BY LOCAL DEVICES ONLY. PROVIDE ROOM CONTROLLER ABOVE ACCESSIBLE CEILING. SENSORCONTROL SHALL BE AUTO ON / AUTO OFF. PROVIDE MANUAL SWITCH AT ENTRANCE FOR SENSOR OVERRIDE.
MAJORMOTION 1 No Yes Yes No No
LC.04 STORAGE, UTILITY, SINGLEOCCUPANT RESTROOMS
CONTROL BY LOCAL DEVICES ONLY. PROVIDE WALLBOX OCCUPANCY SENSOR WITH INTEGRAL MANUALSWITCHING. SENSOR CONTROL SHALL BE AUTO ON / AUTO OFF.
MAJORMOTION 1 No Yes Yes No No
LC.05ELEC, MECH ROOMS,KITCHENS, THEATER
CONTROL BOOTHCONTROL BY LOCAL DEVICES ONLY. MANUAL SWITCHING ONLY. AUTOMATIC SHUTOFF NOT PROVIDED DUE TOSAFETY RISK. N/A 1 No Yes No No No
LC.06 CORRIDORS, LOBBIES
PROVIDE POWER PACKS ABOVE CEILING IN EXISTING CIRCUITS. CONNECT POWER PACKS AND NEWOCCUPANCY SENSORS TO CENTRAL CONTROL PANEL VIA CAT5. CORRIDOR LIGHTING SHALL BE ONCONTINUOUSLY DURING SCHEDULED BUILDING HOURS, AND BE CONTROLLED BY OCCUPANCY SENSORS ATALL OTHER TIMES (AUTO ON / AUTO OFF). MANUAL SWITCH ADJACENT TO PANEL SHALL PROVDE MANUALOVERRIDE OF SCHEDULE. SEE "CENTRAL LIGHTING CONTROL SYSTEM ONE-LINE DIAGRAM" ON SHEET E503.
MAJORMOTION
SEEDETAIL No Yes Yes Yes No
LC.07 EXHIBIT HALLSIX EXISTING SECTIONS ARE CONTROLLED BY AN EXISTING GE CONTROL SYSTEM IN ELEC 124. TIE THE TWONEW SECTIONS INTO EXISTING SYSTEM. DEVICES IN THIS ROOM DO NOT NEED TO BE THE SAMEMANUFACTURER AS THE REST OF THE BUILDING, INSTEAD MATCH THE EXISTING DEVICES AS CLOSELY ASPOSSIBLE. SEE "EXHIBIT HALL LIGHTING CONTROL DETAIL" ON E503 FOR DETAILS.
N/A SEEDETAIL Yes Yes No No No
LC.08 THEATER SEATINGNORMAL OVERHEAD LIGHTING IN THEATER HOUSE SHALL BE CONTROLLED BY THEATRICAL SYSTEM(ELECTRICAL CONTRACTOR RESPONSIBLE FOR CONDUIT PATHS, SEE PLAN KEYED NOTES, AND ET SHEETS FORDETAIL). EMERGENCY LIGHTING AND BACKSTAGE WORK/EGRESS LIGHTING SHALL BE CONTROLLED PER"THEATER EMERGENCY LIGHTING CONTROL SYSTEM ONE-LINE DIAGRAM" ON SHEET E503.
N/A SEEDETAIL No Yes No No No
LC.09 EXTERIOR
ALL EXTERIOR LIGHTING SHALL BE SWITCHED BY CENTRAL CONTROL PANEL, POLE AND TRELLIS LIGHTINGSHALL BE DIMMED BY CENTRAL CONTROL PANEL. CERTAIN EXTERIOR RECEPTACLES DESIGNATED FORHOLIDAY LIGHTING SHALL ALSO BE SWITCHED BY CENTRAL CONTROL PANEL. CENTRAL PHOTOCELL ON ROOFSHALL SWITCH OFF ALL EXTERIOR LIGHTING DURING DAYLIGHT HOURS. DURING NIGHTTIME HOURS, LIGHTINGSHALL BE SWITCHED ON A PROGRAMMABLE SHCHEDULE AND OVERRIDDEN FOR EVENTS BY MANUALCONTROLS. SEE "CENTRAL LIGHTING CONTROL SYSTEM ONE-LINE DIAGRAM" ON SHEET E503.
N/A SEEDETAIL Yes Yes No Yes Yes
GENERAL LIGHTING NOTES1
UNLESS OTHERWISE NOTED, ALL NEW LIGHT FIXTURES REPLACE EXISTING IN SAME ORSIMILAR LOCATIONS. RECONNECT TO EXISTING CIRCUITS. UNLESS OTHERWISE NOTED INLIGHT FIXTURE SCHEDULE, NEW LED FIXTURES HAVE UNIVERSAL VOLTAGE DRIVERS FORUSE WITH 120V OR 277V AS NEEDED.
2NEW LIGHTING CONTROL DEVICES ARE NOT SHOWN ON PLAN, EXCEPT TO INDICATESWITCH LOCATIONS. REFER TO LIGHTING CONTROL SCENRIO LEGEND FOR REQUIREDDEVICES IN EACH SPACE. EXACT QUANTITY AND LOCATION OF SENSORS, POWER PACKS,ETC, SHALL BE DETERMINED BY CONTROLS SUPPLIER AND SHOWN IN SHOP DRAWINGS.
3REFER TO LIGHTING CONTROL DETAILS AND SCHEDULES ON SHEET E503 FORINFORMATION ON WHICH CIRCUITS WILL BE CONTROLLED BY CENTRAL CONTROL SYSTEMS,AND HOW THEY ARE CONNECTED.
Mar
kD
ate
Des
crip
tion
18/
24/1
7AD
DEN
DU
M 1
P
NLC.07LC.07
D
LC.04
LC.04
LC.04
LC.06
LC.06
LC.06
LC.04
P
D
N
P
N
N
EL101A1EL101A1
C3
B
C1
D
A
D
C1
C2
B
B B B
J2E
H2 H2E
H2H2
H2 H2
H2H2
H2 H2
J2E
J2
SERVER RME132
STORAGEE130
CORR #4E129
EXHIBIT HALL #2E126
STORAGEE130
CORR #4E129
VESTE128
STOR 5E127
EXHIBIT HALL #1E121
H2EH2 H2EH2
J2E
J2
J2E
J2
J2J2EJ2
J2E H2H2H2
H2H2H2
BB
26.46
26.46
A
B
WE
WE
W
EX2
EX2EX2
EX2
H1
H1
H1
EXHIBIT HALL"ROOM 7"
EXHIBIT HALL"ROOM 6"
A/V
A/V
26.46
26.46
26.46
26.46
26.46
EX
EXISTING CORRIDOR CKT
EXISTING STORAGE E131 LTG CKT
STORAGE 1E131
STOR 5E125
EXISTING STORAGE E125 LTG CKT
EXISTING WALLPACK LTG CKT
L - 26
AC - 23
AC - 27
L - 30AC - 27
L - 30
L - 30
L - 30 L - 31
L - 31 L - 31
L - 31
L - 28
AC - 21
AC - 25
AC - 25
EX
EX
"ROOM 5" "ROOM 4"
NEW"ROOM 2"
"ROOM 1"
PARTITION PARTITION
PARTITION PARTITION
PAR
TITI
ON
NEW
PAR
TITI
ON
NEW PARTITION NEW PARTITION
NEW"ROOM 6"
NEW"ROOM 3"
(COMBINE ZONES OF EXISTING ROOMS 2 AND 3)
"ROOM 5" "ROOM 4"
"ROOM 2" "ROOM 3"
"ROOM 1"
PARTITION PARTITION
PARTITION PARTITION
PAR
TITI
ON
PAR
TITI
ONTO
BE
REMO
VED
463
TUR
NE R
DR
, SU
ITE
104A
DU
RAN
GO
, CO
813
03PH
ON
E : 9
70-3
8 5-1
570
FAX:
970
-385
-156
9
ME C
HAN
ICAL
, ELE
CTR
ICA L
& EN
V IR
ON
ME N
TAL
ENG
INEE
RIN
G IN
C.
A
B
C
D
E
A
B
C
D
E
1 2 3 4 5 6
DRAWN BY:
CHECKED BY:
PROJECT NO:
GREER-STAFFORD/SJCF, INC.C
SHEET TITLE
DRAWING SHEET
ISSU
E:
THIS DRAWING IS INCOMPLETE AND NOT TO BE USED FOR CONSTRUCTION UNLESS IT IS STAMPED, SIGNED, AND DATED BELOW
1 2 3 4 5 6
2017-07-20
8/22/2
017 7
:14:29
PM
C:\U
sers\
ambe
r\Doc
umen
ts\15
13_C
OF_C
ivic_
R17_
ambe
r.rvt
EL102
ELECTRICALLIGHTING PLAN -EXHIBIT HALLADDITION
1513
6/26
/201
7
FARM
ING
TON
CIV
IC C
ENTE
R R
ENO
VATI
ON
S &
EXPA
NSIO
N
200
W.
ARRIN
GTO
N,
FARM
ING
TON
, N
M 8
7401
CIT
Y O
F FA
RM
ING
TON
AW/NB
AW
N 1/8" = 1'-0"
ELECTRICAL LIGHTING PLAN - EXHIBIT HALL ADDITIONA3
KEYED NOTES
26.46
LOCATION FOR CONTROL STATIONS SPECIFIED IN EXHIBIT HALL LIGHTING CONTROLSYSTEM DETAIL, SHEET E503. SWITCHES MARKED 'N' REPRESENT THE NETWORKEDMULTI-BUTTON SWITCH. SWITCHES MARKED 'D' REPRESENT THE SEPARATEINCANDESCENT DIMMERS FOR THE CHANDELIERS. SWITCHES MARKED 'P' REPRESENT THEOPERABLE PARTITION SWITCHES. GROUP ALL SWITCHES NEATLY WITH AUDIO/VISUALCONTROL STATION WHERE APPLICABLE.
NOTES:
1. All lighting control products shall be same manufacturer. Exceptions must be requested in writing.
2. Pre-approved manufacturers are Wattstopper, Eaton/Greengate, and Acuity/NLight. Others must be pre-approvedprior to bidding (see specifications for prior approval request deadline).
3. All occupancy sensors shall be dual technology, ceiling or corner mounted, unless noted otherwise below.
4. Occupancy sensor layout is not shown on drawings due to variation in sensing range between manufacturers.Where occupancy sensing is indicated for a space, provide quantity of sensors required for complete coverage (minoror major motion as indicated below) based on sensing range of the proposed product line. Provide device layout onfloorplan in submittal package.
LIGHTING CONTROL SCENARIO LEGEND
APPLIES TO DESCRIPTION COVERAGE CONTROLZONES
MANUALDIMMING
MANUALSWITCHING
OCCUPANCYSENSING
SCHEDULEDON/OFF
DAYLIGHTSENSING
LC.01 MEETING ROOMS CONTROL BY LOCAL DEVICES ONLY. PROVIDE ROOM CONTROLLER ABOVE ACCESSIBLE CEILING. SENSORCONTROL SHALL BE MANUAL ON / AUTO OFF.
MINORMOTION 2 Yes Yes Yes No No
LC.02 OFFICES, DRESSING ROOMS CONTROL BY LOCAL DEVICES ONLY. PROVIDE WALLBOX OCCUPANCY SENSOR WITH INTEGRAL MANUALDIMMING. SENSOR CONTROL SHALL BE AUTO ON / AUTO OFF.
MINORMOTION 1 Yes Yes Yes No No
LC.03 MULTI-OCCUPANTRESTROOMS
CONTROL BY LOCAL DEVICES ONLY. PROVIDE ROOM CONTROLLER ABOVE ACCESSIBLE CEILING. SENSORCONTROL SHALL BE AUTO ON / AUTO OFF. PROVIDE MANUAL SWITCH AT ENTRANCE FOR SENSOR OVERRIDE.
MAJORMOTION 1 No Yes Yes No No
LC.04 STORAGE, UTILITY, SINGLEOCCUPANT RESTROOMS
CONTROL BY LOCAL DEVICES ONLY. PROVIDE WALLBOX OCCUPANCY SENSOR WITH INTEGRAL MANUALSWITCHING. SENSOR CONTROL SHALL BE AUTO ON / AUTO OFF.
MAJORMOTION 1 No Yes Yes No No
LC.05ELEC, MECH ROOMS,KITCHENS, THEATER
CONTROL BOOTHCONTROL BY LOCAL DEVICES ONLY. MANUAL SWITCHING ONLY. AUTOMATIC SHUTOFF NOT PROVIDED DUE TOSAFETY RISK. N/A 1 No Yes No No No
LC.06 CORRIDORS, LOBBIES
PROVIDE POWER PACKS ABOVE CEILING IN EXISTING CIRCUITS. CONNECT POWER PACKS AND NEWOCCUPANCY SENSORS TO CENTRAL CONTROL PANEL VIA CAT5. CORRIDOR LIGHTING SHALL BE ONCONTINUOUSLY DURING SCHEDULED BUILDING HOURS, AND BE CONTROLLED BY OCCUPANCY SENSORS ATALL OTHER TIMES (AUTO ON / AUTO OFF). MANUAL SWITCH ADJACENT TO PANEL SHALL PROVDE MANUALOVERRIDE OF SCHEDULE. SEE "CENTRAL LIGHTING CONTROL SYSTEM ONE-LINE DIAGRAM" ON SHEET E503.
MAJORMOTION
SEEDETAIL No Yes Yes Yes No
LC.07 EXHIBIT HALLSIX EXISTING SECTIONS ARE CONTROLLED BY AN EXISTING GE CONTROL SYSTEM IN ELEC 124. TIE THE TWONEW SECTIONS INTO EXISTING SYSTEM. DEVICES IN THIS ROOM DO NOT NEED TO BE THE SAMEMANUFACTURER AS THE REST OF THE BUILDING, INSTEAD MATCH THE EXISTING DEVICES AS CLOSELY ASPOSSIBLE. SEE "EXHIBIT HALL LIGHTING CONTROL DETAIL" ON E503 FOR DETAILS.
N/A SEEDETAIL Yes Yes No No No
LC.08 THEATER SEATINGNORMAL OVERHEAD LIGHTING IN THEATER HOUSE SHALL BE CONTROLLED BY THEATRICAL SYSTEM(ELECTRICAL CONTRACTOR RESPONSIBLE FOR CONDUIT PATHS, SEE PLAN KEYED NOTES, AND ET SHEETS FORDETAIL). EMERGENCY LIGHTING AND BACKSTAGE WORK/EGRESS LIGHTING SHALL BE CONTROLLED PER"THEATER EMERGENCY LIGHTING CONTROL SYSTEM ONE-LINE DIAGRAM" ON SHEET E503.
N/A SEEDETAIL No Yes No No No
LC.09 EXTERIOR
ALL EXTERIOR LIGHTING SHALL BE SWITCHED BY CENTRAL CONTROL PANEL, POLE AND TRELLIS LIGHTINGSHALL BE DIMMED BY CENTRAL CONTROL PANEL. CERTAIN EXTERIOR RECEPTACLES DESIGNATED FORHOLIDAY LIGHTING SHALL ALSO BE SWITCHED BY CENTRAL CONTROL PANEL. CENTRAL PHOTOCELL ON ROOFSHALL SWITCH OFF ALL EXTERIOR LIGHTING DURING DAYLIGHT HOURS. DURING NIGHTTIME HOURS, LIGHTINGSHALL BE SWITCHED ON A PROGRAMMABLE SHCHEDULE AND OVERRIDDEN FOR EVENTS BY MANUALCONTROLS. SEE "CENTRAL LIGHTING CONTROL SYSTEM ONE-LINE DIAGRAM" ON SHEET E503.
N/A SEEDETAIL Yes Yes No Yes Yes
GENERAL LIGHTING NOTES1
UNLESS OTHERWISE NOTED, ALL NEW LIGHT FIXTURES REPLACE EXISTING IN SAME ORSIMILAR LOCATIONS. RECONNECT TO EXISTING CIRCUITS. UNLESS OTHERWISE NOTED INLIGHT FIXTURE SCHEDULE, NEW LED FIXTURES HAVE UNIVERSAL VOLTAGE DRIVERS FORUSE WITH 120V OR 277V AS NEEDED.
2NEW LIGHTING CONTROL DEVICES ARE NOT SHOWN ON PLAN, EXCEPT TO INDICATESWITCH LOCATIONS. REFER TO LIGHTING CONTROL SCENRIO LEGEND FOR REQUIREDDEVICES IN EACH SPACE. EXACT QUANTITY AND LOCATION OF SENSORS, POWER PACKS,ETC, SHALL BE DETERMINED BY CONTROLS SUPPLIER AND SHOWN IN SHOP DRAWINGS.
3REFER TO LIGHTING CONTROL DETAILS AND SCHEDULES ON SHEET E503 FORINFORMATION ON WHICH CIRCUITS WILL BE CONTROLLED BY CENTRAL CONTROL SYSTEMS,AND HOW THEY ARE CONNECTED.
Mar
kD
ate
Des
crip
tion
18/
24/1
7AD
DEN
DU
M 1
N 1/16" = 1'-0"
Lighting Control Zoning Detail - NewA2N 1/16" = 1'-0"
Lighting Control Zoning Detail - ExistingA1
1
LC.05
LC.05
LC.05
LC.05
LC.05
LC.05
LC.05
PANEL SDP
PANEL HPA
EX MECH RMT005
EX BOILER ROOMT006
EX EQUIP ROOMT002
EX STAIR FOYERT001
EX LIFT PITT004
EX STORAGET003
H2E
H2H2E
H2E
H2
H2
H2
H2E
H2
H2
H2
H2
H2
H2
H2
H2
H2
H2
H2E
H2E
H2
H2
H2
H2
H2
H2
H2E
H2H2
H2
H2
H2
H2E
H2E
H2
H2E
H2E
H2
H2E
H2
H2
H2E
H2
26.40
26.40
26.40
26.40
EX
EX
EX
EX
EX
EX
EX
PANEL LADPANEL AV
NEW AUDIORACK
1
463
TUR
NE R
DR
, SU
ITE
104A
DU
RAN
GO
, CO
813
03PH
ON
E : 9
70-3
8 5-1
570
FAX:
970
-385
-156
9
ME C
HAN
ICAL
, ELE
CTR
ICA L
& EN
V IR
ON
ME N
TAL
ENG
INEE
RIN
G IN
C.
A
B
C
D
E
A
B
C
D
E
1 2 3 4 5 6
DRAWN BY:
CHECKED BY:
PROJECT NO:
GREER-STAFFORD/SJCF, INC.C
SHEET TITLE
DRAWING SHEET
ISSU
E:
THIS DRAWING IS INCOMPLETE AND NOT TO BE USED FOR CONSTRUCTION UNLESS IT IS STAMPED, SIGNED, AND DATED BELOW
1 2 3 4 5 6
2017-07-20
8/22/2
017 7
:14:35
PM
C:\U
sers\
ambe
r\Doc
umen
ts\15
13_C
OF_C
ivic_
R17_
ambe
r.rvt
EL103
ELECTRICALLIGHTING PLAN -THEATER -BASEMENT
1513
6/26
/201
7
FARM
ING
TON
CIV
IC C
ENTE
R R
ENO
VATI
ON
S &
EXPA
NSIO
N
200
W.
ARRIN
GTO
N,
FARM
ING
TON
, N
M 8
7401
CIT
Y O
F FA
RM
ING
TON
AW/NB
AW
N 1/8" = 1'-0"
ELECTRICAL LIGHTING PLAN - THEATER - BASEMENTA1
KEYED NOTES26.40 THROUGHOUT THEATER BASEMENT, ALL EXISTING MANUAL LIGHT SWITCHES ARE TO
REMAIN (NOT SHOWN). REPLACE ALL FIXTURES IN SAME LOCATIONS.
NOTES:
1. All lighting control products shall be same manufacturer. Exceptions must be requested in writing.
2. Pre-approved manufacturers are Wattstopper, Eaton/Greengate, and Acuity/NLight. Others must be pre-approvedprior to bidding (see specifications for prior approval request deadline).
3. All occupancy sensors shall be dual technology, ceiling or corner mounted, unless noted otherwise below.
4. Occupancy sensor layout is not shown on drawings due to variation in sensing range between manufacturers.Where occupancy sensing is indicated for a space, provide quantity of sensors required for complete coverage (minoror major motion as indicated below) based on sensing range of the proposed product line. Provide device layout onfloorplan in submittal package.
LIGHTING CONTROL SCENARIO LEGEND
APPLIES TO DESCRIPTION COVERAGE CONTROLZONES
MANUALDIMMING
MANUALSWITCHING
OCCUPANCYSENSING
SCHEDULEDON/OFF
DAYLIGHTSENSING
LC.01 MEETING ROOMS CONTROL BY LOCAL DEVICES ONLY. PROVIDE ROOM CONTROLLER ABOVE ACCESSIBLE CEILING. SENSORCONTROL SHALL BE MANUAL ON / AUTO OFF.
MINORMOTION 2 Yes Yes Yes No No
LC.02 OFFICES, DRESSING ROOMS CONTROL BY LOCAL DEVICES ONLY. PROVIDE WALLBOX OCCUPANCY SENSOR WITH INTEGRAL MANUALDIMMING. SENSOR CONTROL SHALL BE AUTO ON / AUTO OFF.
MINORMOTION 1 Yes Yes Yes No No
LC.03 MULTI-OCCUPANTRESTROOMS
CONTROL BY LOCAL DEVICES ONLY. PROVIDE ROOM CONTROLLER ABOVE ACCESSIBLE CEILING. SENSORCONTROL SHALL BE AUTO ON / AUTO OFF. PROVIDE MANUAL SWITCH AT ENTRANCE FOR SENSOR OVERRIDE.
MAJORMOTION 1 No Yes Yes No No
LC.04 STORAGE, UTILITY, SINGLEOCCUPANT RESTROOMS
CONTROL BY LOCAL DEVICES ONLY. PROVIDE WALLBOX OCCUPANCY SENSOR WITH INTEGRAL MANUALSWITCHING. SENSOR CONTROL SHALL BE AUTO ON / AUTO OFF.
MAJORMOTION 1 No Yes Yes No No
LC.05ELEC, MECH ROOMS,KITCHENS, THEATER
CONTROL BOOTHCONTROL BY LOCAL DEVICES ONLY. MANUAL SWITCHING ONLY. AUTOMATIC SHUTOFF NOT PROVIDED DUE TOSAFETY RISK. N/A 1 No Yes No No No
LC.06 CORRIDORS, LOBBIES
PROVIDE POWER PACKS ABOVE CEILING IN EXISTING CIRCUITS. CONNECT POWER PACKS AND NEWOCCUPANCY SENSORS TO CENTRAL CONTROL PANEL VIA CAT5. CORRIDOR LIGHTING SHALL BE ONCONTINUOUSLY DURING SCHEDULED BUILDING HOURS, AND BE CONTROLLED BY OCCUPANCY SENSORS ATALL OTHER TIMES (AUTO ON / AUTO OFF). MANUAL SWITCH ADJACENT TO PANEL SHALL PROVDE MANUALOVERRIDE OF SCHEDULE. SEE "CENTRAL LIGHTING CONTROL SYSTEM ONE-LINE DIAGRAM" ON SHEET E503.
MAJORMOTION
SEEDETAIL No Yes Yes Yes No
LC.07 EXHIBIT HALLSIX EXISTING SECTIONS ARE CONTROLLED BY AN EXISTING GE CONTROL SYSTEM IN ELEC 124. TIE THE TWONEW SECTIONS INTO EXISTING SYSTEM. DEVICES IN THIS ROOM DO NOT NEED TO BE THE SAMEMANUFACTURER AS THE REST OF THE BUILDING, INSTEAD MATCH THE EXISTING DEVICES AS CLOSELY ASPOSSIBLE. SEE "EXHIBIT HALL LIGHTING CONTROL DETAIL" ON E503 FOR DETAILS.
N/A SEEDETAIL Yes Yes No No No
LC.08 THEATER SEATINGNORMAL OVERHEAD LIGHTING IN THEATER HOUSE SHALL BE CONTROLLED BY THEATRICAL SYSTEM(ELECTRICAL CONTRACTOR RESPONSIBLE FOR CONDUIT PATHS, SEE PLAN KEYED NOTES, AND ET SHEETS FORDETAIL). EMERGENCY LIGHTING AND BACKSTAGE WORK/EGRESS LIGHTING SHALL BE CONTROLLED PER"THEATER EMERGENCY LIGHTING CONTROL SYSTEM ONE-LINE DIAGRAM" ON SHEET E503.
N/A SEEDETAIL No Yes No No No
LC.09 EXTERIOR
ALL EXTERIOR LIGHTING SHALL BE SWITCHED BY CENTRAL CONTROL PANEL, POLE AND TRELLIS LIGHTINGSHALL BE DIMMED BY CENTRAL CONTROL PANEL. CERTAIN EXTERIOR RECEPTACLES DESIGNATED FORHOLIDAY LIGHTING SHALL ALSO BE SWITCHED BY CENTRAL CONTROL PANEL. CENTRAL PHOTOCELL ON ROOFSHALL SWITCH OFF ALL EXTERIOR LIGHTING DURING DAYLIGHT HOURS. DURING NIGHTTIME HOURS, LIGHTINGSHALL BE SWITCHED ON A PROGRAMMABLE SHCHEDULE AND OVERRIDDEN FOR EVENTS BY MANUALCONTROLS. SEE "CENTRAL LIGHTING CONTROL SYSTEM ONE-LINE DIAGRAM" ON SHEET E503.
N/A SEEDETAIL Yes Yes No Yes Yes
GENERAL LIGHTING NOTES1
UNLESS OTHERWISE NOTED, ALL NEW LIGHT FIXTURES REPLACE EXISTING IN SAME ORSIMILAR LOCATIONS. RECONNECT TO EXISTING CIRCUITS. UNLESS OTHERWISE NOTED INLIGHT FIXTURE SCHEDULE, NEW LED FIXTURES HAVE UNIVERSAL VOLTAGE DRIVERS FORUSE WITH 120V OR 277V AS NEEDED.
2NEW LIGHTING CONTROL DEVICES ARE NOT SHOWN ON PLAN, EXCEPT TO INDICATESWITCH LOCATIONS. REFER TO LIGHTING CONTROL SCENRIO LEGEND FOR REQUIREDDEVICES IN EACH SPACE. EXACT QUANTITY AND LOCATION OF SENSORS, POWER PACKS,ETC, SHALL BE DETERMINED BY CONTROLS SUPPLIER AND SHOWN IN SHOP DRAWINGS.
3REFER TO LIGHTING CONTROL DETAILS AND SCHEDULES ON SHEET E503 FORINFORMATION ON WHICH CIRCUITS WILL BE CONTROLLED BY CENTRAL CONTROL SYSTEMS,AND HOW THEY ARE CONNECTED.
Mar
kD
ate
Des
crip
tion
18/
24/1
7AD
DEN
DU
M 1
D3
3
3
3
D
N
D
3
D
3 3
DD
ND
D
D
D
D
3 3
D
N
LC.01
LC.02
LC.02
LC.02
LC.02
LC.02
LC.03
LC.03
LC.05
LC.04
LC.04
LC.05
LC.06
LC.08
LC.06LC.06
LC.06
LC.06
LC.06
LC.02
LC.03 LC.03
LC.06
LC.08
LC.08
LC.08
LC.06
LC.06
LC.06
LC.02 LC.02
LC.02
LC.02
P
P
P
P
P
P
P
P PP
P
P
P
X74.B1
PANEL LAC
PANEL LAB
PANEL LAA
ENTRYE100
VESTT101
WOMENT103
MENT113
WOMEN'S DRESST123
WOMENT124
MEN'S DRESST126
MENT127
BOARD RMT122
MAKE-UPT125
STAGET116
AUDITORIUMT115
JANT114
JANT104
PRIVATE DRESST121
PRIVATE DRESST120 JAN
T119
PRIVATE DRESST118
CORRIDORT117
S STAIRT105
W STAIRT112
LOBBYT100
CORRIDORT102
STORAGE 1T109
TECHNICALT110
SUPERVISORST108
STORAGE 2T107
OFFICE 3T106
X74.B1
X74.B1
X74.B1
X74.B1
X74.B1
J2
J2E
J2
J2
J2
F4
F4
H2
J4
J4
H2
H2
J4
J4
J4
J4
H2
H2
J4
J4E
H2
U
U
U
U
UU
U U
J2
EXL
EXR
EXR
EX EXL
EXL
EXL
EX EX
EXLR
J4, a
J4, a
J4, a
J4, a
J4, b
J4, b
J4, b
J4, b
J4, b
J4, b
J4, b
J4, b
J4
J4
J4E J4
J4
J4
J4E
J4
J4
J4
J4
J4 J4
J4 J4
J4E
J4 J4
J4
J4
J4J4
J2E J2 J2E J2 J2E
J2
J2E
J2
J2E
J2
J1
J2E
J2
J2E
J2E
J2
J2EJ2E J2 J2E
J2E
J2
J2E
F4
F4
F4
F4F4F4
J1J1J1J1E
J1
J1
J1
J1E
J1
F2
J1E
F2J1J1E
ab
T T T T T
T
T
T
T
T
CORRIDORLIGHTING
CONTROLSSEE E503
T
T
T26.45
J2EJ2 J2
G1
G1
G1
G1
G1G1
G1
ER
EXR
G1ER
W
INV-1
ER
TO BOLLARDS(OR TRELLIS FIXTURES)
SEE SITE PLAN
EX
ER
EX
J2E
J2
G1G1
G1
J2
J2
G1
G1
G1 G1
O-W
W
W
VESTT128
HWE
26.59
N N
N N
N N
N N
26.8226.82
N
N N
N
N
N
N
N
TYP
N
EX
EX
PANEL LAH
EM LTGCNTRL
26.29
STAGET116
AUDITORIUMT115
R26
R26
R26
R26
Q3
Q3
Q3
Q3
R24
R24
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4
S4S4S4S4S4S4S4S4S4S4S4S4S4
R22
R22
Q3
Q3
Q3Q3
R24
R41
R24
R22
R22
S4
R22
S4
S4
S4
S4
S4
S4
S4S4
S4S4
S4S4
W STAIRT202
S STAIRT200
CORRIDORT201
CORRIDORT201
CRL BOOTH 2T206
MIXING BOOTHT205
CRL BOOTH 1T204
Q3
Q3
Q3
Q3
26.9926.99
26.99
26.99
26.99
26.9926.99
26.99
26.9926.99
26.99
S4
Q1
Q1
Q1
Q1
Q1
Q1
Q1
Q1
Q1
Q1
Q1
Q1
Q1
Q1
R22
S4
Q3
Q3
Q1Q1 Q1 Q1 Q1 Q1
Q1 Q1 Q1 Q1 Q1 Q1 Q1
Q1
IN HALL BELOW
IN HALL BELOW
IN HALL BELOW
IN HALL BELOW
DASHED LINES INDICATE SURFACE MOUNTED WIREWAY AVAILABLE AS ACCESSORY TO FIXTURES(TYPICAL, THIS PLAN)
463
TUR
NE R
DR
, SU
ITE
104A
DU
RAN
GO
, CO
813
03PH
ON
E : 9
70-3
8 5-1
570
FAX:
970
-385
-156
9
ME C
HAN
ICAL
, ELE
CTR
ICA L
& EN
V IR
ON
ME N
TAL
ENG
INEE
RIN
G IN
C.
A
B
C
D
E
A
B
C
D
E
1 2 3 4 5 6
DRAWN BY:
CHECKED BY:
PROJECT NO:
GREER-STAFFORD/SJCF, INC.C
SHEET TITLE
DRAWING SHEET
ISSU
E:
THIS DRAWING IS INCOMPLETE AND NOT TO BE USED FOR CONSTRUCTION UNLESS IT IS STAMPED, SIGNED, AND DATED BELOW
1 2 3 4 5 6
2017-07-20
8/22/2
017 7
:35:26
PM
C:\U
sers\
ambe
r\Doc
umen
ts\15
13_C
OF_C
ivic_
R17_
ambe
r.rvt
EL104
ELECTRICALLIGHTING PLAN -THEATER - GROUNDFLOOR
1513
6/26
/201
7
FARM
ING
TON
CIV
IC C
ENTE
R R
ENO
VATI
ON
S &
EXPA
NSIO
N
200
W.
ARRIN
GTO
N,
FARM
ING
TON
, N
M 8
7401
CIT
Y O
F FA
RM
ING
TON
AW
AW
N 1/8" = 1'-0"
ELECTRICAL LIGHTING PLAN - THEATER - GROUND FLOORA1
KEYED NOTES26.29 COORDINATE LOCATION OF ALL BACKSTAGE ELECTRICAL EQUIPMENT WITH THEATER
CONTRACTOR PRIOR TO ROUGH-IN. PAINT EQUIPMENT BLACK.
26.45ON BOTTOM OF STAIR LANDING, PROVIDE NEW SURFACE MOUNTED TRACK FOR ARTDISPLAY. SUPPLY FROM NEAREST EXISTING TRACK LIGHTING CIRCUIT. SPRINKLER PIPINGMUST BE RUN TO THIS AREA ALSO; USE SURFACE MOUNTED CONDUIT, GROUP WITH NEWSURFACE PIPING, AND PAINT TO MATCH.
26.59IN ELEVATOR PIT, AT ACCESSIBLE LOCATION FOR MAINTENANCE, PROVIDE GFCIRECEPTACLE WITH WEATHERPROOF IN-USE COVER. CONNECT GFCI RECEPTACLE ANDPIT/SHAFT LIGHT FIXTURES TO A SINGLE DEDICATED CIRCUIT. DO NOT CONNECT LIGHTFIXTURES TO THE LOAD SIDE OF THE GFCI DEVICE.
26.82 COORDINATE WITH GC FOR MIRROR CUTS NECESSARY TO ACCOMMODATE WALL MOUNTEDMAKEUP LIGHTS.
26.99
PROPOSED LOCATION FOR 12V POWER SUPPLY FOR NEARBY AISLE FIXTURES. REPLACEEXISTING JUNCTION BOX AND SECURELY MOUNT POWER SUPPLY UNDER SEAT.ALTERNATELY, ANY OF THE OTHER EXISTING UNDER-SEAT JUNCTION BOXES MAY BE USED(FOR OTHER LOCATIONS, SEE DEMOLITION PLAN, KEYED NOTE 26.57). REUSE EXISTINGCIRCUITING (PANEL LAA PER ORIGINAL DRAWINGS, VERIFY). COORDINATE WITHTHEATERICAL SYSTEMS CONTRACTOR ON LOCATION FOR SWITCHING. TEST ALL CIRCUITSPRIOR TO REUSE AND REPORT ANY DEFICIENCIES TO ENGINEER.
N 1/8" = 1'-0"
ELECTRICAL LIGHTING PLAN - THEATER - FLOOR LEVELA4
NOTES:
1. All lighting control products shall be same manufacturer. Exceptions must be requested in writing.
2. Pre-approved manufacturers are Wattstopper, Eaton/Greengate, and Acuity/NLight. Others must be pre-approvedprior to bidding (see specifications for prior approval request deadline).
3. All occupancy sensors shall be dual technology, ceiling or corner mounted, unless noted otherwise below.
4. Occupancy sensor layout is not shown on drawings due to variation in sensing range between manufacturers.Where occupancy sensing is indicated for a space, provide quantity of sensors required for complete coverage (minoror major motion as indicated below) based on sensing range of the proposed product line. Provide device layout onfloorplan in submittal package.
LIGHTING CONTROL SCENARIO LEGEND
APPLIES TO DESCRIPTION COVERAGE CONTROLZONES
MANUALDIMMING
MANUALSWITCHING
OCCUPANCYSENSING
SCHEDULEDON/OFF
DAYLIGHTSENSING
LC.01 MEETING ROOMS CONTROL BY LOCAL DEVICES ONLY. PROVIDE ROOM CONTROLLER ABOVE ACCESSIBLE CEILING. SENSORCONTROL SHALL BE MANUAL ON / AUTO OFF.
MINORMOTION 2 Yes Yes Yes No No
LC.02 OFFICES, DRESSING ROOMS CONTROL BY LOCAL DEVICES ONLY. PROVIDE WALLBOX OCCUPANCY SENSOR WITH INTEGRAL MANUALDIMMING. SENSOR CONTROL SHALL BE AUTO ON / AUTO OFF.
MINORMOTION 1 Yes Yes Yes No No
LC.03 MULTI-OCCUPANTRESTROOMS
CONTROL BY LOCAL DEVICES ONLY. PROVIDE ROOM CONTROLLER ABOVE ACCESSIBLE CEILING. SENSORCONTROL SHALL BE AUTO ON / AUTO OFF. PROVIDE MANUAL SWITCH AT ENTRANCE FOR SENSOR OVERRIDE.
MAJORMOTION 1 No Yes Yes No No
LC.04 STORAGE, UTILITY, SINGLEOCCUPANT RESTROOMS
CONTROL BY LOCAL DEVICES ONLY. PROVIDE WALLBOX OCCUPANCY SENSOR WITH INTEGRAL MANUALSWITCHING. SENSOR CONTROL SHALL BE AUTO ON / AUTO OFF.
MAJORMOTION 1 No Yes Yes No No
LC.05ELEC, MECH ROOMS,KITCHENS, THEATER
CONTROL BOOTHCONTROL BY LOCAL DEVICES ONLY. MANUAL SWITCHING ONLY. AUTOMATIC SHUTOFF NOT PROVIDED DUE TOSAFETY RISK. N/A 1 No Yes No No No
LC.06 CORRIDORS, LOBBIES
PROVIDE POWER PACKS ABOVE CEILING IN EXISTING CIRCUITS. CONNECT POWER PACKS AND NEWOCCUPANCY SENSORS TO CENTRAL CONTROL PANEL VIA CAT5. CORRIDOR LIGHTING SHALL BE ONCONTINUOUSLY DURING SCHEDULED BUILDING HOURS, AND BE CONTROLLED BY OCCUPANCY SENSORS ATALL OTHER TIMES (AUTO ON / AUTO OFF). MANUAL SWITCH ADJACENT TO PANEL SHALL PROVDE MANUALOVERRIDE OF SCHEDULE. SEE "CENTRAL LIGHTING CONTROL SYSTEM ONE-LINE DIAGRAM" ON SHEET E503.
MAJORMOTION
SEEDETAIL No Yes Yes Yes No
LC.07 EXHIBIT HALLSIX EXISTING SECTIONS ARE CONTROLLED BY AN EXISTING GE CONTROL SYSTEM IN ELEC 124. TIE THE TWONEW SECTIONS INTO EXISTING SYSTEM. DEVICES IN THIS ROOM DO NOT NEED TO BE THE SAMEMANUFACTURER AS THE REST OF THE BUILDING, INSTEAD MATCH THE EXISTING DEVICES AS CLOSELY ASPOSSIBLE. SEE "EXHIBIT HALL LIGHTING CONTROL DETAIL" ON E503 FOR DETAILS.
N/A SEEDETAIL Yes Yes No No No
LC.08 THEATER SEATINGNORMAL OVERHEAD LIGHTING IN THEATER HOUSE SHALL BE CONTROLLED BY THEATRICAL SYSTEM(ELECTRICAL CONTRACTOR RESPONSIBLE FOR CONDUIT PATHS, SEE PLAN KEYED NOTES, AND ET SHEETS FORDETAIL). EMERGENCY LIGHTING AND BACKSTAGE WORK/EGRESS LIGHTING SHALL BE CONTROLLED PER"THEATER EMERGENCY LIGHTING CONTROL SYSTEM ONE-LINE DIAGRAM" ON SHEET E503.
N/A SEEDETAIL No Yes No No No
LC.09 EXTERIOR
ALL EXTERIOR LIGHTING SHALL BE SWITCHED BY CENTRAL CONTROL PANEL, POLE AND TRELLIS LIGHTINGSHALL BE DIMMED BY CENTRAL CONTROL PANEL. CERTAIN EXTERIOR RECEPTACLES DESIGNATED FORHOLIDAY LIGHTING SHALL ALSO BE SWITCHED BY CENTRAL CONTROL PANEL. CENTRAL PHOTOCELL ON ROOFSHALL SWITCH OFF ALL EXTERIOR LIGHTING DURING DAYLIGHT HOURS. DURING NIGHTTIME HOURS, LIGHTINGSHALL BE SWITCHED ON A PROGRAMMABLE SHCHEDULE AND OVERRIDDEN FOR EVENTS BY MANUALCONTROLS. SEE "CENTRAL LIGHTING CONTROL SYSTEM ONE-LINE DIAGRAM" ON SHEET E503.
N/A SEEDETAIL Yes Yes No Yes Yes
GENERAL LIGHTING NOTES1
UNLESS OTHERWISE NOTED, ALL NEW LIGHT FIXTURES REPLACE EXISTING IN SAME ORSIMILAR LOCATIONS. RECONNECT TO EXISTING CIRCUITS. UNLESS OTHERWISE NOTED INLIGHT FIXTURE SCHEDULE, NEW LED FIXTURES HAVE UNIVERSAL VOLTAGE DRIVERS FORUSE WITH 120V OR 277V AS NEEDED.
2NEW LIGHTING CONTROL DEVICES ARE NOT SHOWN ON PLAN, EXCEPT TO INDICATESWITCH LOCATIONS. REFER TO LIGHTING CONTROL SCENRIO LEGEND FOR REQUIREDDEVICES IN EACH SPACE. EXACT QUANTITY AND LOCATION OF SENSORS, POWER PACKS,ETC, SHALL BE DETERMINED BY CONTROLS SUPPLIER AND SHOWN IN SHOP DRAWINGS.
3REFER TO LIGHTING CONTROL DETAILS AND SCHEDULES ON SHEET E503 FORINFORMATION ON WHICH CIRCUITS WILL BE CONTROLLED BY CENTRAL CONTROL SYSTEMS,AND HOW THEY ARE CONNECTED.
Mar
kD
ate
Des
crip
tion
18/
24/1
7AD
DEN
DU
M 1
1
1
FV
FV
FV
FV
TWC
P
HD
FV
FV
FV
FV
PANEL LAE
STAGET116
MIXING BOOTHT205
CRL BOOTH 1T204
CRL BOOTH 2T206
W STAIRT202
S STAIRT200
CORRIDORT201
MEZZANINET203
LOBBYT100
MR
26.63
26.64
26.6626.66
26.67
26.76
Panel LAE
26.76
LAH - 9
26.76
LAH - 12
LAH -2,4,6
26.64
26.68
1
Panel LAE
463
TUR
NE R
DR
, SU
ITE
104A
DU
RAN
GO
, CO
813
03PH
ON
E : 9
70-3
8 5-1
570
FAX:
970
-385
-156
9
ME C
HAN
ICAL
, ELE
CTR
ICA L
& EN
V IR
ON
ME N
TAL
ENG
INEE
RIN
G IN
C.
A
B
C
D
E
A
B
C
D
E
1 2 3 4 5 6
DRAWN BY:
CHECKED BY:
PROJECT NO:
GREER-STAFFORD/SJCF, INC.C
SHEET TITLE
DRAWING SHEET
ISSU
E:
THIS DRAWING IS INCOMPLETE AND NOT TO BE USED FOR CONSTRUCTION UNLESS IT IS STAMPED, SIGNED, AND DATED BELOW
1 2 3 4 5 6
2017-07-20
8/22/2
017 7
:33:17
PM
C:\U
sers\
ambe
r\Doc
umen
ts\15
13_C
OF_C
ivic_
R17_
ambe
r.rvt
EP105
ELEC.POWER & SPEC.SYS. PLAN - THEATER- MEZZANINE
1513
6/26
/201
7
FARM
ING
TON
CIV
IC C
ENTE
R R
ENO
VATI
ON
S &
EXPA
NSIO
N
200
W.
ARRIN
GTO
N,
FARM
ING
TON
, N
M 8
7401
CIT
Y O
F FA
RM
ING
TON
AW/NB
AW
N 1/8" = 1'-0"
ELECTRICAL POWER & SPECIAL SYSTEMS PLAN - THEATER - MEZZANINEA1
KEYED NOTES26.63
PROVIDE HEAT DETECTORS TO INITIATE ELEVATOR SHUTDOWN WITHIN 2FT OF EACHSPRINKLER HEAD IN ELEVATOR PIT, AND AT ELEVATOR DISCONNECT. HEAT DETECTORSSHALL HAVE BOTH A LOWER TEMPERATURE SETTING AND A HIGHER SENSITIVITY ASCOMPARED TO THE SPRINKLER HEADS, PER ASME A17.1-6.15.4. COORDINATE WITH FIREPROTECTION CONTRACTOR.
26.64PROVIDE SMOKE DETECTORS TO INITIATE ELEVATOR RECALL FUNCTION ADJACENT TOEACH SPRINKLER HEAD IN ELEVATOR PIT, AT ELEVATOR DISCONNECT, AND IN ELEVATORLOBBY ON EACH FLOOR. CONNECT TO ELEVATOR CONTROLLER. COORDINATE WITH FIREPROTECTION CONTRACTOR.
26.66REFER TO PERFORMANCE LIGHTING SHEETS FOR ELECTRICAL WORK RELATED TOREPLACEMENT OF EXISTING DISTRIBUTION STRIPS AND TERMINAL BOXES LOCATED INCATWALKS, ABOVE STAGE, AND AT STAGE LEVEL.
26.67MOTORIZED RIGGING SYSTEM PROVIDED BY THEATRICAL CONTRACTOR AND INSTALLED BYELECTRICAL CONTRACTOR. REFER TO PERFORMANCE LIGHTING SHEETS FOR LAYOUTDETAILS, AND REFER TO EQUIPMENT CONNECTION SCHEDULE FOR ELECTRICAL DETAILS.
26.68 COORDINATE EXACT LOCATION WITH THEATER CONSULTANT PRIOR TO ROUGH-IN.
26.76 PROVIDE 120V/20A BRANCH CIRCUIT(S) TO THIS LOCATION FOR THEATRICAL DEVICE. REFERTO PERFORMANCE LIGHTING DRAWINGS FOR DETAILS.
GENERAL ELECTRICAL PLAN...1
SEE THEATER DRAWINGS, PERFORMANCE LIGHTING DRAWINGS, AND AUDIO-VISUALSYSTEM DRAWINGS FOR ADDITIONAL ELECTRICAL REQUIREMENTS NOT SHOWN ON POWEROR LIGHTING SHEETS.
2ELECTRICAL CONTRACTOR RESPONSIBLE FOR TELEPHONE/DATA BACKBOXES ANDCONDUIT WITH PULL STRING TO ABOVE CEILING ONLY, UNLESS OTHERWISE NOTED.OWNER TO PROVIDE WIRING, TERMINATIONS, WALL PLATES, AND EQUIPMENT.
3REFER TO THEATER SYSTEMS (TS) AND AUDIO-VISUAL (AV) SHEETS FOR ADDITIONAL WORKBY ELECTRICAL CONTRACTOR. COORDINATE WITH THEATER AND AUDIO VISUAL SYSTEMSCONTRACTORS WHERE APPLICABLE.
Mar
kD
ate
Des
crip
tion
18/
24/1
7AD
DEN
DU
M 1
CONTROL PANELAT MAIN OFFICE
CONTXFMR
LOW
VO
LTA
GE
IN
PU
TS
PROVIDE RECESSED CONTROL PANEL WITH CAPABILITY FOR 7 DAY PROGRAMMED SCHEDULES, HOLIDAY OVERRIDES, AND ASTRONOMICAL TIME CLOCK. SEE LIGHTING CONTROL PANEL CIRCUIT SCHEDULE FOR PROGRAMMING.
PROVIDE A TOUCHSCREEN CONTROL STATION IN THE MAIN RECEPTION AREA (COORDINATE EXACT LOCATION WITH OWNER). PROGRAM TOUCHSCREEN TO CONTROL CIRCUITS IN THE GROUPINGS SHOWN ON THE CENTRAL CONTROL SYSTEM CIRCUIT SCHEDULE. PROGRAM THREE PRE-SET DIMMING LEVELS FOR EACH DIMMING ZONE, LABELED HIGH-MEDIUM-LOW (PLUS AN OFF BUTTON).
INTERCEPT EXISTING CIRCUITS AT LOCATION OF EXISTING MANUAL SWITCHES (SEE PLAN). REMOVE SWITCHES AND PROVIDE CONTACTOR TO BE CONTROLLED BY CENTRAL PANEL. SURFACE MOUNT CONTACTOR ON WALL IN NON-PUBLIC AREA.
INTERCEPT EXISTING CIRCUIT AT LOCATION OF EXISTING MANUAL SWITCH (SEE PLAN). REMOVE SWITCHES AND PROVIDE POWER PACK TO BE CONTROLLED BY CENTRAL PANEL. LOCATE POWER PACK ABOVE NEAREST ACCESSIBLE CEILING (OR SURFACE MOUNT ON WALL IN NON-PUBLIC AREA).
PROVIDE PERMANENT WEATHERPROOF LABELS UNDER COVERS OF ALL RECEPTACES CONTROLLED BY THIS PANEL, READING "HOLIDAY LIGHTS".
INTERCEPT EXISTING CORRIDOR LIGHTING CIRCUITS AND INSTALL POWER PACKS ABOVE ACCESSIBLE CEILINGS (WALL MOUNTING ACCEPTABLE IN UTILITY ROOMS). CONNECT POWER PACKS TO CENTRAL PANEL. LABEL POWER PACKS AND NOTE LOCATIONS FOR AS-BUILT DRAWINGS.
PROVIDE WEATHERPROOF ENCLOSURE ADJACENT TO EACH OF 4 EXTERIOR PANELS. INSIDE ENCLOSURE, PROVIDE ONE POWERPACK FOR EACH CIRCUIT ON THAT PANEL LISTED IN CENTRAL CONTROL PANEL SCHEDULE. PROVIDE DIMMING POWER PACKS FOR CIRCUITS MARKED WITH DIMMING IN SCHEDULE. POWER PACKS CAN BE DAISY CHAINED WITH CAT5 INSIDE ENCLOSURE, AND GROUP CONNECTED TO MASTER PANEL WITH CAT5 FOR CENTRALIZED CONTROL OF ALL ZONES.
PROVIDE EXTERIOR SWITCH STATION WITH ON/OFF BUTTON FOR EACH CONTROL GROUP LISTED. SEE SITE PLAN, COORDINATE EXACT LOCATION TO BE NEATLY GROUPED WITH AUDIO CONTROL STATION.
CL.01
CL.02
CL.03
CL.04
CL.05
CL.06
CL.07
CL.08
CENTRAL LIGHTING CONTROL LEGEND:
CENTRAL LIGHTING CONTROL KEYED NOTES:
CL.01 NEW120V CIRCUIT
ROOFTOPPHOTOCELL
THEATER BLDG CORRIDOR LIGHTINGAND WALLPACKS(EXISTING CIRCUITS)
LV INPUT
EXISTINGCIRCUITS
CL.03( 9 ) POWER PACKS
EXHIBIT HALL CORRIDOR LIGHTINGAND WALLPACKS(EXISTING CIRCUITS)
LV INPUT
EXISTINGCIRCUITS
OCCUPANCY SENSORS IN THEATER BLDG GROUND LEVEL CORRIDORS (SINGLE ZONE)
SWITCH "Holiday Lights"
SWITCH "Center Poles"
SWITCH "Outer Poles"
SWITCH "Bollard Lights"
SWITCH "Trellis Lights"
SWITCH "Sculpture Lights"
OCCUPANCY SENSORS IN EXHIBIT BLDG CORRIDORS (SINGLE ZONE)
LOW
VO
LTA
GE
OU
TPU
TS
CL.03
CL.08
OCCUPANCY SENSORS IN THEATER BLDG MEZZANINE LEVEL CORRIDORS (SINGLE ZONE)
( 15 ) POWER PACKS
CL.06
CL.06
LV INPUT
NEW 120V CIRCUITS
CL.04 CL.05CL.07
CONTROLLED EXTERIOR CIRCUITS ON PANEL "LAG"(THEATER ROOF)
LV INPUT
NEW 120V CIRCUITS
CL.04 CL.05CL.07
CONTROLLED EXTERIOR CIRCUITS ON PANEL "LAF"(THEATER SITE)
POWER PACKS IN 3R ENCLOSURE
LV INPUT
NEW 120V CIRCUITS
CL.04 CL.05CL.07
CONTROLLED EXTERIOR CIRCUITS ON PANEL "D"(EXHIBIT HALL SITE)
LV INPUT
NEW 120V CIRCUITS
CL.04 CL.05CL.07
CONTROLLED EXTERIOR CIRCUITS ON PANEL "F"(EXHIBIT HALL ROOF)
TOUCHSCREENCONTROL STATION
CL.02
EXISTING TO REMAIN =
NEW DEVICE =
NEW LINE VOLT WIRE =
NEW CONTROL WIRE =
POWER PACKS IN 3R ENCLOSURE
POWER PACKS IN 3R ENCLOSURE
POWER PACKS IN 3R ENCLOSURE
ACUITY:
CENTRAL PANEL : NLIGHT SYSTEM
POWER PACKS : NPP16 DIMMING POWER PACK
TOUCHSCREEN : FRESCO 7" LCD
The products above may be bid without prior approval. For any other manufacturer, submit complete product information to engineer before bidding (reference pre-approval deadline specified in bid documents). Review and approval decision will be issued in final addendum.
ACCEPTABLE MANUFACTURERS:
LEVITON:
CENTRAL PANEL : GREENMAX SYSTEM
POWER PACKS : DRC 0-10V SMARTPACK
TOUCHSCREEN : SAPPHIRE 7" LCD
CONTROL PANEL
SEATING AREA EMERGENCY LIGHTING
CONTXFMR
LV IN
PU
T
EMERGENCYBYPASS
POWERPANEL
LAH
120/208V
FACP
TE.01
PROGRAM CONTROL PANEL SUCH THAT THIS RELAY IS SWITCHED TO "ON" WHEN THE FIRE ALARM CONTROL PANEL SIGNALS A FIRE STATUS, BUT REMAINS OFF AT ALL OTHER TIMES.
PROGRAM CONTROL PANEL SUCH THAT THIS RELAY IS CONTROLLED BY MANUAL LOW VOLTAGE SWITCHES LABELED "BACKSTAGE WORK LIGHTS" UNDER NORMAL CONDITIONS, BUT OVERRIDDEN TO "ON" IF THE FIRE ALARM CONTROL PANEL SIGNALS A FIRE STATUS.
NOT USED.
TO SUPPLY THE NEW EMERGENCY FIXTURES ABOVE THEATER SEATING AREA, RE-USE EXISTING CIRCUIT CURRENTLY FEEDING THE EMERGENCY BATTERY IN THE CONTROL BOOTH.
INTERCEPT EXISTING CIRCUIT SERVING BACKSTAGE WORK FIXTURES, AND ROUTE THROUGH LIGHTING CONTROL PANEL. REPLACE EXISTING LINE VOLTAGE SWITCHES WITH NEW LOW VOLTAGE SWITCHES LABELED "BACKSTAGE WORK LIGHTS" AND PROVIDE LOW VOLTAGE CONNECTION TO CONTROL PANEL.
NOT USED.
PROVIDE INVERTER, SPECIFIED IN LIGHTING FIXTURE SCHEDULE. PROVIDE CHARGING CIRCUIT IN SAME PANEL THAT SUPPLIES ASSOCIATED FIXTURES.
THE FUNCTION OF THE EMERGENCY BYPASS MODULE IS TO SENSE WHETHER NORMAL UTILITY POWER IS AVAILABLE (VIA CONNECTION TO EXISTING POWER PANEL). IF UTILITY POWER FAILS, THE MODULE WILL AUTOMATICALLY BYPASS THE LIGHTING CONTROL PANEL AND TRANSFER THE LOAD TO THE INVERTER. PROVIDE 4" ENCLOSURE FOR MODULE AND SURFACE MOUNT ADJACENT TO LIGHTING CONTROL PANEL.
TE.01
TE.02
TE.03
TE.04
TE.05
TE.06
TE.07
TE.08
THEATER EMERGENCY LIGHTING CONTROL LEGEND:
THEATER EMERGENCY LIGHTING CONTROL KEYED NOTES: TE.05
BACKSTAGE WORK LIGHTING(DOUBLES AS EGRESS)
TE.02
(2) LV SWITCHES, LABEL:
"BACKSTAGE WORK LIGHTS"SWITCHING
RELAY
(2) LV SWITCHES, LABEL:
"AISLE LIGHTS"
EMERGENCYBYPASS
PROVIDE 120V-20A CONTROLS CIRCUIT
TE.08
TE.08
TE.04
INVERTERINV-2
TE.07
SWITCHINGRELAY
SWITCHINGRELAY
EXISTING TO REMAIN =
NEW DEVICE =
NEW LINE VOLT WIRE =
NEW CONTROL WIRE =
ACCEPTABLE MANUFACTURERS:Manufacturer of this system shall be same as manufacturer of central lighting control system.Refer to central system detail for pre-approved manufacturers and substitutin procedure.
SPARE
EH.02EXISTING GENERAL ELECTRIC "LIGHTSWEEP" MODULAR CONTROL SYSTEM, TO REMAIN AND BE EXPANDED TO ACCOMMODATE EXHIBIT HALL ADDITION. SYSTEM CONSISTS OF TWO PANELS, COMPONENTS CAN BE ADDED TO EITHER PANEL AS SPACE ALLOWS.
USE SPARE OR PROVIDE NEW LINE VOLTAGE RELAY (GE MODEL # CLCRMS6)
USE SPARE OR PROVIDE NEW 0-10V DIMMING MODULE (GE MODEL # CLCDIM4)
UTILIZE EXISTING SPARE DRY CONTACT OUTPUTS IN PANEL.
UTILIZE EXISTING SPARE DRY CONTACT INPUTS IN PANEL.
PROVIDE NEW 8 BUTTON SWITCHES, GE MODEL # CLCSWT8. REFER TO PLAN FOR QUANTITY AND LOCATIONS. MATCH LABELING OF EXISTING.
PROVIDE NEW INCANDESCENT SLIDE DIMMER FOR DECORATIVE CHANDELIER, MATCHING EXISTING DIMMERS. LUTRON VIERTI, MODEL # VT-600M-W-WH. REFER TO PLAN FOR LOCATIONS.
CONNECT KEYED SWITCHES PROVIDED WITH PARTITION OPERATORS TO CONTROL PANEL. REFER TO PLAN FOR QUANTITY AND LOCATIONS.
INCLUDE SITE VISITS BY FACTORY AUTHORIZED REPRESENTATIVES AS NECESSARY FOR RE-PROGRAMMING OF GE PANEL AND TOKISTAR CONTROLLER FOR ADDED ZONES AND SWITCHES.
EH.01
EH.02
EH.03
EH.04
EH.05
EH.06
EH.07
EH.08
EH.09
EXISTING TO REMAIN =
NEW DEVICE =
EXHIBIT HALL LIGHTING CONTROL LEGEND:
EXHIBIT HALL LIGHTING CONTROL KEYED NOTES:
EXI
STI
NG
CO
NTR
OL
PA
NE
L S
YS
TEM
LC
P-1
(MA
STE
R)
/ L
CP
-2 (S
EC
ON
DA
RY
)
EXISTING INVERTER
CAPACITY: 2100 WNEW TOTAL: 1344 W
TYPE A FIXTURES(TYP. OF 2 ROOMS)
277 V
0-10 V
277 V
0-10 V
EXISTING UL 924 RELAY
120 V
DMX
EXISTING TOKISTAR CONTROLLER
120 V NEW TRIAC
DIMMER
EXISTING8 BUTTON SWITCHES
NEW KEYED
SWITCHES
EXISTING8 BUTTON SWITCHES
NEW 8 BUTTON SWITCHES
CAT 5
EH.03
EH.02
EH.03
EH.02
EH.02
EH.04
EH.07
EH.08
EH.08
EH.01
TYPE B FIXTURES(TYP. OF 2 ROOMS)
TYPE C FIXTURES(TYP. OF 2 ROOMS)
TYPE D FIXTURES(TYP. OF 2 ROOMS)
PARTITION OPERATOR(TYP. OF 3 WALLS)
480 V
2 # 18 CU
PANEL MDP1
3 # 18 CUEH.05
ACCEPTABLE MANUFACTURERS:Provide the above specified products only. Due to the need to match the existing components, no substitutions will be allowed for this sytem. Contact at GE Application Support familiar with project : Cornel Saramet, (604) 421-8634Sales Representative Contact : Mark Delaney, Mountain States Agency, (505) 867-5034
EH.09
EH.09
NEW LINE VOLT WIRE =
NEW CONTROL WIRE =
REFER TO LIGHTING ZONING DETAIL ON SHEET EL102. ONE OF THE EXISTING OPERABLE PARTITIONS IS BEING REMOVED IN THIS PROJECT, CONTROL ZONES FOR THE ROOMS ON EITHER SIDE OF IT ARE TO BE COMBINED. THIS WILL FREE UP SPARE RELAYS, DIMMERS, AND INPUTS IN CONTROL PANEL FOR USE IN NEW ADDITION.
EXHIBIT HALL LIGHTING CONTROL GENERAL NOTE:
1
463
TUR
NE R
DR
, SU
ITE
104A
DU
RAN
GO
, CO
813
03PH
ON
E : 9
70-3
8 5-1
570
FAX:
970
-385
-156
9
ME C
HAN
ICAL
, ELE
CTR
ICA L
& EN
V IR
ON
ME N
TAL
ENG
INEE
RIN
G IN
C.
A
B
C
D
E
A
B
C
D
E
1 2 3 4 5 6
DRAWN BY:
CHECKED BY:
PROJECT NO:
GREER-STAFFORD/SJCF, INC.C
SHEET TITLE
DRAWING SHEET
ISSU
E:
THIS DRAWING IS INCOMPLETE AND NOT TO BE USED FOR CONSTRUCTION UNLESS IT IS STAMPED, SIGNED, AND DATED BELOW
1 2 3 4 5 6
2017-07-20
8/22/2
017 7
:13:14
PM
C:\U
sers\
ambe
r\Doc
umen
ts\15
13_C
OF_C
ivic_
R17_
ambe
r.rvt
E503
LIGHTING CONTROLDETAILS &SCHEDULES
1513
6/26
/201
7
FARM
ING
TON
CIV
IC C
ENTE
R R
ENO
VATI
ON
S &
EXPA
NSIO
N
200
W.
ARRIN
GTO
N,
FARM
ING
TON
, N
M 8
7401
CIT
Y O
F FA
RM
ING
TON
AW
AW
CENTRAL LIGHTING CONTROL SYSTEM ONE-LINE DIAGRAMC3
THEATER EMERGENCY LIGHTING CONTROL SYSTEM ONE-LINE DIAGRAMB3
CIRCUITS CONTROLLED BY NEW CENTRAL CONTROL SYSTEMPANEL CIRCUIT # NAME SCHEDULED NETWORKED
OCCUPANCY SENSOR(S) DIMMING DAYLIGHTHARVESTING
EXT.PHOTOCELL COMMENTS
BOLLARDS
D 11,13 Bollard Lights West Yes No No No Yes
LAF 25,27 Bollard Lights East Yes No No No Yes
CORRIDORS - EXHIBIT HALL
<unnamed> Exhibit Hall Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Exhibit Hall Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Exhibit Hall Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Exhibit Hall Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Exhibit Hall Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Exhibit Hall Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Exhibit Hall Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Exhibit Hall Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
CORRIDORS - THEATER
<unnamed> Theater Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Theater Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Theater Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Theater Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Theater Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Theater Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Theater Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Theater Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Theater Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Theater Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Theater Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Theater Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Theater Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
<unnamed> Theater Corridor Lighting Yes Yes No No No Existing circuits on various panels, circuit numbers unknown.
EXTERIOR WALL LIGHTS
<unnamed> Exhibit Hall Exterior Wall Lights Yes No No No Yes Existing circuits on various panels, circuit numbers unknown.
<unnamed> Theater Exterior Wall Lights Yes No No No Yes Existing circuits on various panels, circuit numbers unknown.
HOLIDAY LIGHTS
D 2 Holiday Lgt Recept West Yes No No No Yes
D 4 Holiday Lgt Recept Bldg Yes No No No Yes
D 6 Holiday Lgt Recept West Yes No No No Yes
F 1 Holiday Lgt Recept Roof Yes No No No Yes
F 2 Holiday Lgt Recept Roof Yes No No No Yes
F 3 Holiday Lgt Recept Roof Yes No No No Yes
F 4 Holiday Lgt Recept Roof Yes No No No Yes
F 5 Holiday Lgt Recept Roof Yes No No No Yes
LAF 6 Holiday Lgt Recept Bldg Yes No No No Yes
LAF 8 Holiday Lgt Recept Center Yes No No No Yes
LAF 10 Holiday Lgt Recept East Yes No No No Yes
LAG 1 Holiday Lgt Recept Roof Yes No No No Yes
LAG 2 Holiday Lgt Recept Roof Yes No No No Yes
LAG 3 Holiday Lgt Recept Roof Yes No No No Yes
LAG 4 Holiday Lgt Recept Roof Yes No No No Yes
LAG 5 Holiday Lgt Recept Roof Yes No No No Yes
POLES, CENTER
LAF 33,35 Pole Lights Center Yes No Yes No Yes
POLES, OUTER
D 7,9 Pole Lights West Yes No Yes No Yes
LAF 29,31 Pole Lights East Yes No Yes No Yes
SCULPTURE LIGHTING
D 19 Sculpture Flood Lighting Yes No No No Yes
TRELLIS LIGHTS
D 15,17 Trellis Lighting West (Alternate) Yes No Yes No Yes
LAF 37,39 Trellis Lighting East (Alternate) Yes No Yes No Yes
TOTAL CIRCUITS : 48
CIRCUITS BEING ADDED TO EXISTING EXHIBIT HALL CONTROL SYSTEMPANEL CIRCUIT # NAME CONTROL REQUIRED COMMENTS
L 28 LGT - Type A Room 6 RELAY + 0-10V
L 26 LGT - Type A Room 7 RELAY + 0-10V
L 31 LGT - Type B Room 6 RELAY + 0-10V + EM OVERRIDE ROUTE CIRCUIT THROUGH UL924 CONTACTOR, WHICH WILL OVERRIDE CONTROL STATE TO ON/FULL BRIGHTNESS AND TRANSFERPOWER TO INVERTER UPON LOSS OF UTILITY POWER.
L 30 LGT - Type B Room 7 RELAY + 0-10V + EM OVERRIDE ROUTE CIRCUIT THROUGH UL924 CONTACTOR, WHICH WILL OVERRIDE CONTROL STATE TO ON/FULL BRIGHTNESS AND TRANSFERPOWER TO INVERTER UPON LOSS OF UTILITY POWER.
AC 25 LGT - Type C Room 6 RELAY + DMX VIA TOKISTAR CONTROLLER EXISTING FIXTURE DMX DIMMING UNITS ARE DAISY-CHAINED TOGETHER. CONNECT NEW FIXTURES' DMX IN LINE. ON/OFF CONTROL IS BYCONTROL PANEL VIA BUTTON IN EXHIBIT HALL, COLOR SELECTION MUST BE MADE AT TOKISTAR CONTROLLER IN ELECTRICAL ROOM
AC 27 LGT - Type C Room 7 RELAY + DMX VIA TOKISTAR CONTROLLER EXISTING FIXTURE DMX DIMMING UNITS ARE DAISY-CHAINED TOGETHER. CONNECT NEW FIXTURES' DMX IN LINE. ON/OFF CONTROL IS BYCONTROL PANEL VIA BUTTON IN EXHIBIT HALL, COLOR SELECTION MUST BE MADE AT TOKISTAR CONTROLLER IN ELECTRICAL ROOM
AC 21 LGT - Type D Room 6 RELAY + TRIAC DIMMER ON WALL MATCH CONTROL SCHEME FOR EXISTING CHANDELIERS. ON/OFF IS CONTROLLED BY RELAY IN CONTROL PANEL, BUT DIMMING LEVEL ISCONTROLLED FROM MANUAL DIMMING STATION ONLY.
AC 23 LGT - Type D Room 7 RELAY + TRIAC DIMMER ON WALL MATCH CONTROL SCHEME FOR EXISTING CHANDELIERS. ON/OFF IS CONTROLLED BY RELAY IN CONTROL PANEL, BUT DIMMING LEVEL ISCONTROLLED FROM MANUAL DIMMING STATION ONLY.
EXHIBIT HALL EXISTING LIGHTING CONTROL SYSTEM ONE-LINE DIAGRAMA3
CIRCUITS CONTROLLED BY NEW THEATER EMERGENCY CONTROL PANELPANEL CIRCUIT # NAME CONTROL REQUIRED COMMENTS
LAH 1 Backstage Work Lights RELAY + EM OVERRIDE
LAH 3 Seating Area EM Lights RELAY + EM OVERRIDE
Mar
kD
ate
Des
crip
tion
18/
24/1
7AD
DEN
DU
M 1
SS
FIRE RISER KEYED NOTES
MAGNETIC DOOR HOLDER TYP. MDH
TT
TS FS
(LOCKING CLIP CB)20A, 120V
20A 120V
C
SEE NOTE:
FAA
FACP
DS DS
RI
VOICE/STROBE TYP.
STROBE, TYP.
HORN /STROBE WP TYP.
TO COMM. TERM. BD.
FIRE /SMOKEDAMPER TYP.
F/S DAMPER RELAYADDRESSABLE
MANUAL PULLSTATION, TYP.
SMOKEDETECTOR,TYP.
HEAT DETECTOR, TYP.
DUCT SMOKEDETECTOR, TYP.
REMOTEINDICATOR, TYP
KITCHEN HOODSUPPRESSION SYSTEM
17
WP
PROVIDE AND INSTALL A COMPLETE, INTELLIGENT, ADDRESSABLE FIRE ALARM SYSTEM; INCLUDING, BUT NOT LIMITED TO DEVICES, BACK BOXES, CONDUIT SYSTEM, CABLING, EQUIPMENT, ASSOCIATED DEVICES, AND INTERCONNECTIONS. PROVIDE SYSTEM PROGRAMMING, PERSONNEL TRAINING, AND COMMISSIONING. UTILIZE 14-18 GAUGE WIRE, SOLID WIRE ONLY. UNIFORM COLOR CODE FOR WIRING THROUGH OUT. RUN ALL EXISTING CABLING WITHIN CONDUIT, 1/2'' C MINIMUM. PLENUM RATED CABLE ON J-HOOK APPROVED IN ACCESSIBLE CEILINGS. SEE SPECIFICATION SECTION 28 31 11 FOR APPROVED MANUFACTURERS. ALL DEVICES BELOW TO BE BY SAME MANUFACTURER AS PANEL.
1. FIRE ALARM CONTROL PANEL (FACP): SURFACE PER PLAN MOUNTED CABINET. CABLES INCLUDE A 20A, 120V BRANCH CIRCUIT, LOCKING CLIP. FINAL LOCATION SHALL BE VERIFIED WITH THE OWNER PRIOR TO ROUGH-IN. INCLUDE 4 - 3/4" EMT CONDUIT STUB OUTS FROM THE FACP TO THE ACCESSIBLE CEILING CAVITY FOR FUTURE CONNECTIONS. NOTE THAT THE OWNER WILL BE RESPONSIBLE TO OBTAIN CENTRAL STATION MONITORING SERVICES. INSTALL AS-BUILT FIRE ALARM SYSTEM DRAWING COVERED BY GLASS MOUNTED TO BACK OF FACP.
2. MANUAL PULL STATION: DOUBLE ACTION, NON-BREAK GLASS TYPE.
3. PHOTOELECTRIC SMOKE DETECTOR, RECONNECT EXISTING AND PROVIDE NEW AS INDICATED.
4. HEAT DETECTOR: 135 DEGREE FIXED TEMPERATURE.
5. VOICE/STROBE VERTICAL WALL MOUNT.
6. STROBE: VERTICAL WALL MOUNT.
7. HORN/STROBE, WEATHERPROOF COVER: WITH HUMIDITY GASKET.
8. FIRE ALARM ANNUNCIATOR AT ENTRY: LCD TYPE, SEMI-RECESSED MOUNTED. LOCATE ANNUNCIATOR AT A POSITION DETERMINED BY THE FIRE MARSHALL AND COORDINATED WITH THE ARCHITECT.
9. DUCT SMOKE DETECTOR/SENSOR/BAFFLE 1 SMOKE DETECTOR AT THE SUPPLY DUCT AND 1 AT THE RETURN DUCT. LOCATION AND SAMPLE TUBE LENGTH IN ACCORDANCE WITH THE NFPA INSTALLATION GUIDELINES AND UMC. SMOKE DETECTOR SHALL BE PHOTOELECTRIC TYPE. PROVIDE RELAYS AS REQUIRED TO SHUT DOWN A.H.U. FAN.
10. REMOTE ALARM INDICATOR: LOCATE IN CORRIDOR CEILING DIRECTLY BELOW DUCT SMOKE DETECTOR OR AS NEAR DUCT DETECTOR LOCATION AS POSSIBLE.
11. FIRE / SMOKE DAMPER: 120V MOTORIZED ACTUATOR PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL A DISCONNECT MEANS AT EACH MOTORIZED DAMPER WITH 2 #12 + #12 GRD, 1/2''C (MIN) TO A 20A, 120V BRANCH CIRCUIT VIA ADDRESSABLE FIRE SMOKE DAMPER RELAY. DAMPER SHALL REMAIN OPEN WHILE THE ASSOCIATED MECHANICAL UNIT IS IN OPERATION, AND SHALL CLOSE IN THE EVENT OF SMOKE DETECTOR, DUCT DETECTOR, HEAT DETECTOR ACTIVATION, OR POWER LOSS. INCLUDE PROGRAMMING SO THAT MECHANICAL UNIT(S) SHALL SHUT DOWN PRIOR TO DAMPER CLOSING.
12. FIRE / SMOKE DAMPER RELAY: 20A, 120V CONTACTS, COIL VOLTAGE SHALL BE COORDINATED WITH FIRE ALARM SYSTEM. COIL SHALL BE CONTROLLED VIA SIGNAL FROM FACP. REFER TO FIRE / SMOKE DAMPER NOTE.
13. 4 PAIR, CAT 5 TELEPHONE CABLE, 3/4"C TO THE TELEPHONE TERMINAL BOARD.
14. MAGNETIC DOOR HOLDER: SERIES, COORDINATE SINGLE OR DOUBLE DOOR, SEMI-RECESSED WALL MOUNTED, VERIFY SHORT CATCH OR LONG CATCH PLATE WITH EACH DOOR. DOOR HOLDERS ARE PROVIDED AND INSTALLED UNDER ARCHITECTURAL SECTIONS, AND CONNECTED BY THE ELECTRICAL CONTRACTOR. SECURE BACK BOX TO STUD, INCLUDE BRIDGING WHERE REQUIRED. COORDINATE FINAL MOUNTING HEIGHT AND EXACT LOCATION WITH ARCHITECT'S PLANS.MAGNETIC DOOR HOLDER: SERIES, COORDINATE SINGLE OR DOUBLE DOOR, SEMI-RECESSED WALL MOUNTED, VERIFY SHORT CATCH OR LONG CATCH PLATE WITH EACH DOOR. DOOR HOLDERS ARE PROVIDED AND INSTALLED UNDER ARCHITECTURAL SECTIONS, AND CONNECTED BY THE ELECTRICAL CONTRACTOR. SECURE BACK BOX TO STUD, INCLUDE BRIDGING WHERE REQUIRED. COORDINATE FINAL MOUNTING HEIGHT AND EXACT LOCATION WITH ARCHITECT'S PLANS.
15. EMERGENCY COMMAND COVER. SEE SPECS.
16. LABEL ALL CONDUITS IN ACCORDANCE WITH THE SPECIFICATIONS. COORDINATE ROUTING OF CONDUITS BETWEEN FLOOR LEVELS AND BUILDINGS WITH ALL DISCIPLINES PRIOR TO ROUGH-IN.
17. THE SPECIAL SYSTEMS RISER DIAGRAM DOES NOT REFLECT ALL THE DEVICES REQUIRED. REFER TO THE FLOOR PLANS FOR LOCATION AND QUANTITY OF DEVICES.
18. F/A FLOW SWITCH AND TAMPER SWITCH, PROVIDE @ ALL FIRE SPRINKLER RISER VALVES AND WALL / POST INDICATOR VALVES.
8
1
12
F/SF/S
11
16
13
14
F F F
7
6
5
10
9
4
HD
3
15
2
FF
18
V
ECC
1. EMERGENCY TWO-WAY COMMUNICATION COMMAND UNIT: MANUFACTURED BY TALK-A-PHONE CO. AOR-8 OR EQUAL. COMMAND UNIT SHALL INCLUDE BUILT IN UPS. CABINET SHALL BE CONSTRUCTED OF STAINLESS STEEL WITH TWO ACRYLIC WINDOWS, RECESSED MOUNTED WITH RED PHONE AND 12-KEY PAD-SIZE 24.375"W X 18.375"H X 4.25"D. STROBE/SOUNDER SHALL INDICATE INCOMING CALLS, VISUALLY INDICATE THE IDENTITY OF CALLING RESCUE STATION, AND ENABLE TWO-WAY CONVERSATION. EMERGENCY PERSONNEL SHALL ALSO BE ABLE TO SELECTIVELY CALL ANY RESCUE STATION. UNIT SHALL ALSO COME WITH A SIREN ALERT WHICH COMBINES A SIREN AND STROBE CONSTRUCTED WITHIN A 4" SQUARE UNIT (LOCATION OF SIREN AND STROBE UNIT IS NOT SHOWN ON THE FLOOR PLAN AND SHALL BE LOCATED IN FIELD IN ACCORDANCE WITH THE ARCHITECT'S REQUIREMENTS). THE CONTRACTOR SHALL COORDINATE SYSTEM REQUIREMENTS WITH THE ADA CODE AUTHORITY AND THE ARCHITECT PRIOR TO ROUGH-IN.
2. EMERGENCY TWO-WAY COMMUNICATION PHONE: MANUFACTURED BY TALK-A-PHONE CO. #ETP-100EB-FRONT PANEL SIZE 9.25"W X 11"H/WALL OPENING 4.5"W X 7.5"H X 2.5"D; AND MOUNTING SLEEVE BOX #MS-100 - SIZE 9"W X 11.25"H X 3"D OR EQUAL. FLUSH MOUNTED, STAINLESS STEEL PANEL, CAST METAL RAISED LETTERS AND BRAILLE SIGNAGE FOR ADA COMPLIANCE. INCLUDE SELF ADHESIVE AREA OF RESCUE SIGNS #ETP-SIGN FOR EACH STATION.
3. CONNECT TO NEW DEDICATED PHONE LINE AND DEDICATED 120V/1PH CIRCUIT.
1ST FLOOR
2ND FLOOR
COMMANDUNIT
EMERGENCY PHONE, TYP.CABLING AND 1/2" C (MIN)
PER MANUFACTURER'SREQUIREMENTS, TYP.
2
1
EMERGENCY TWO-WAYCOMMUNICATION RISERDIAGRAM KEYED NOTES
3
FINISHED CEILING
FLOOR
JUNCTION BOX
FLEXIBLE CORD, PER CIRCUITREQUIREMENTS ALLOW 6' SLACK
SINGLE GANG BOX WITH RECEPTACLES OR CORD-CAP CONNECTION, PER PLAN
STRAIN RELIEF
LAY-IN CEILINGWHERE INDICATED
RETRACTABLE CORDREEL
P2000 UNISTRUT
6'6"
J-HOOKS WIRE MGT.
NEW COAX WIRING
1. GE TRU-VISION CAMERA, OR EQUAL.
2. 24 VOLT POWER SUPPLY.
3. COLOR DIGITAL VIDEO RECORDER.
4. COLOR 19" MONITOR.
41
2
3
SECURITY SYSTEM:PROVIDE AND INSTALL A NEW SECURITY SYSTEM WITH COLOR VIDEO CAMERAS, DVRS AND WIRING. LOCATE POWER SUPPLY, DVR, MONITOR IN SUPERVISORS T108
COLOR DIGITALVIDEO RECORDER
24V POWER SUPPLY
VIDEO CAMERAS COLOR MONITOR
120V
KEYED NOTES
POWER BOX(VENDOR USE)
208 V
3W
+ G
SURF
ACE
MOUN
T ON
POL
E BA
SE
POLE TOP FIXTURE
8 FT COPPER CLADSTEEL GROUND ROD
TOP AT 30" BELOW GRADE
POLE RECEPTACLE(HOLIDAY LIGHTS)
50 A
/ 208
V RE
CEPT
ACLE
20 A
/ 120
V GF
CI
RECE
PTAC
LE
20 A
/ 120
V GF
CI
RECE
PTAC
LE
ENCLOSURE AND E.G.C.
REBAR & POLE
E.G.C.E.G.C.
# 10
CU
0-10
V D
IMMI
NG (
2) #
14 C
U
208 V
2W
+ G
120 V
2W
+ G
TO NEXT HOLIDAY LIGHT RECEPTACLE
TO NEXT POLE LIGHT
TO NEXT VENDOR POWER BOX
REFERENCE STRUCTURAL SHEET S302 FOR POLE BASE DETAIL.
SINGLE 20A GFCI RECEPTACLE INCLUDED WITH POLE. CONNECT TO HOLIDAY LIGHT CIRCUIT CONTROLLED BY CENTRAL LIGHTING CONTROL PANEL. REMOVE STANDARD COVER INCLUDED WITH RECEPTACLE, AND REPLACE WITH METAL HEAVY DUTY WHILE-IN-USE WEATHERPROOF COVER. PROVIDE PERMANENT WEATHERPRROF LABEL ON COVER, READING "HOLIDAY LIGHTS."
PROVIDE VENDOR POWER BOX, SURFACE MOUNTED ON POLE BASE WITH TOP OF BOX FLUSH WITH TOP OF POLE BASE. THIS DETAIL DEPICTS LARGEST BOX REQUIRED, SOME POLES ONLY REQUIRE SMALLER 120V BOXES. REFER TO SHEET ES101 FOR PRODUCT SPECIFICATION AND LAYOUT.
REFER TO SITE CIRCUIT CONDUCTOR SCHEDULE, THIS SHEET, FOR WIRE SIZES REQUIRED TO MITIGATE VOLTAGE DROP ON EACH CIRCUIT.
RUN CONTROL CONDUCTORS IN SEPERATE CONDUIT, AND TERMINATE AT DIMMING POWER PACK ADJACENT TO POWER PANEL. REFER TO CENTRAL LIGHTING CONTROL SYSTEM DETAIL, SHEET E503.
REFER TO AUDIO-VISUAL (AV) SHEETS FOR REQUIREMENTS RELATED TO POLE MOUNTED SPEAKERS.
PB.01
PB.02
PB.03
PB.04
PB.05
PB.06
POLE BASE ELECTRICAL DETAIL KEYED NOTES:
PB.03
PB.02
PB.01
PB.04
PB.04
PB.04
PB.05
SPEAKERS
PB.06
TO NEXT SPEAKER OR A/V CABINET
PB.06
ANCHOR
DRAIN
JET
JET + LIGHT
JET
JET
JET
JET
JET
JET
JET
DRAIN
ANCHOR
ANCHOR
ANCHOR
ACTIVATION BOLLARD
CONTROLLER
PUMP
AREA IN WHICH ALL FIXED METAL PARTS MUST BE BONDED, AND NO UNRELATED UNDERGROUND ELECTRICAL MAY BE INSTALLED
MINUMUM EXTENT OF EQUIPOTENTIAL BONDING GRID BENEATH SPLASH PAD
BOUNDARY OF SPLASH PAD
IN SPLASH PAD CONCRETE, PROVIDE AN EQUIPOTENTIAL BONDING GRID (E.B.G.) COMPLYING WITH NEC 680.26(B)(1)(b). GRID AREA SHALL BE THE ENTIRE PAD PLUS AT LEAST 3 FT FROM THE PAD BOUNDARY ON ALL SIDES. GRID MAY CONSIST OF STRUCTURAL REBAR OR WIRE MESH PROVIDED BY CONCRETE INSTALLER, WITH A SOLID #8 CU CONDUCTOR ADDED AROUND THE PERIMETER AND BONDED TO STRUCTURAL STEEL AT FOUR LOCATIONS SPACED EVENLY AROUND THE GRID. IF STRUCTURAL STEEL IS COMPOSED OF SEPERATE PARTS, BOND THESE TOGETHER USING #8 CU WIRE. IF NO STRUCTURAL STEEL IS PRESENT, THE E.P.G. SHALL CONSIST OF # 8 SOLID COPPER WIRE IN A 12" X 12" GRID BONDED AT ALL INTERSECTIONS, INSTALLED IN OR UNDER THE CONCRETE AT 4" TO 6" BELOW SURFACE, WITH AN OUTER WIRE FOLLOWING THE CONTOUR OF THE PAD, BONDED TO THE GRID IN 4 EVENLY SPACED LOCATIONS. USING #8 SOLID CU, BOND ALL OF THE FOLLOWING TO THE OUTER WIRE OF THE E.B.G.:
BOND ALL FIXED METAL PARTS OF SPLASH PAD. THIS INCLUDES BUT IS NOT LIMITED TO: NOZZLES, LIGHTS, DRAINS, AND STRUCTURAL ANCHORS.
BOND ALL FIXED METAL PARTS OF ANY SYSTEM, IF LOCATED WITHIN 5 FT OF THE PAD BOUNDARY. THIS INCLUDES BUT IS NOT LIMITED TO: ELECTRICAL CONDUIT, WATER PIPING, AND DRAIN PIPING, WHETHER ASSOCIATED WITH SPLASH PAD SYSTEM OR NOT.
BOND ALL FIXED METAL PARTS ASSOCIATED WITH THE SPLASH PAD SYSTEM, IN ANY LOCATION. THIS INCLUDES BUT IS NOT LIMITED TO: ELECTRICAL CONDUIT, WATER PIPING, AND DRAIN PIPING, REGARDLESS OF DISTANCE FROM PAD.
BOND ALL FIXED METAL PARTS IN THE ABOVE GROUND VAULT HOUSING THE SPLASH PAD EQUIPMENT. THIS INCLUDES BUT IS NOT LIMITED TO: EQUIPMENT ENCLOSURES, CONDUIT, AND ANY METAL PARTS OF THE VAULT ITSELF. ENSURE THAT EQUIPMENT ENCLOSURES ARE ALSO BONDED TO THE EQUIPMENT GROUNDING CONDUCTOR FROM THE SUPPLY PANELBOARD.
SP.01
SP.02
SP.03
SP.04
SP.05
SPLASH PAD GROUNDING & BONDING DETAIL KEYED NOTES:
SP.05
3'
5'
ANYMETALPIPING
SP.04
SP.01
SP.03
SP.02
SP.04
TYPICAL
GFCICIRCUIT(S)
SPLASH PAD GROUNDING & BONDING GENERAL NOTES:
ALL UNDERGROUND CONDUIT IS PART OF BASE BID ROUGH IN FOR SPLASH PAD (STUB UP UNDER PAVEMENT). GROUNDING / BONDING WORK AND ABOVE GROUND COMPONENTS ARE PART OF WATER FEATURE ALTERNATE BID.
IN GENERAL, COMPLY WITH NEC 680 (II) AS IF THE SPLASH PAD WERE A PERMANENTLY INSTALLED CONCRETE POOL. IF NEEDED, SUBMIT RFI FOR CLARIFICATION OF HOW TO APPLY ARTICLE 680.
ALL BONDING REFERED TO ABOVE MUST UTILIZE A CONNECTION METHOD LISTED FOR GROUNDING USE, AND RATED FOR THE ENVIRONMENTAL CONDITIONS WHERE IT IS USED (FOR EXAMPLE, CONNECTIONS WITHIN EQUIPMENT VAULT MUST BE LISTED FOR CORROSIVE ENVIRONMENTS).
ALL SINGLE PHASE CIRCUITS ASSOCIATED WITH SPLASH PAD SYSTEM MUST HAVE GFCI PROTECTION FOR PERSONNEL. THIS INCLUDES ANY SINGLE PHASE 208 VOLT OR 240 VOLT CIRCUITS, AND ALSO INCLUDES HARDWIRED CONNECTIONS.
ALL ASSOCIATED ELECTRICAL CONDUIT MUST BE PVC OR RMC. USE RMC ONLY WHERE EXPOSED.
BRANCH WIRING METHODS FOR INTEGRAL LIGHTING IN SPLASH PAD SHALL COMPLY WITH NEC 680.23 AND 680.24, SIMILAR TO UNDERWATER POOL LUNINAIRES, WHERE PHYSICALLY APPLICABLE.
DO NOT INSTALL ANY UNDERGROUND ELECTRICAL WITHIN 5 FT OF SPLASH PAD BOUNDARY, UNLESS IT IS NECESSARY FOR THE FUNCTION OF THE SPLASH PAD SYSTEM ITSELF.
1.
2.
3.
4.
5.
6.
7.
463
TUR
NE R
DR
, SU
ITE
104A
DU
RAN
GO
, CO
813
03PH
ON
E : 9
70-3
8 5-1
570
FAX:
970
-385
-156
9
ME C
HAN
ICAL
, ELE
CTR
ICA L
& EN
V IR
ON
ME N
TAL
ENG
INEE
RIN
G IN
C.
A
B
C
D
E
A
B
C
D
E
1 2 3 4 5 6
DRAWN BY:
CHECKED BY:
PROJECT NO:
GREER-STAFFORD/SJCF, INC.C
SHEET TITLE
DRAWING SHEET
ISSU
E:
THIS DRAWING IS INCOMPLETE AND NOT TO BE USED FOR CONSTRUCTION UNLESS IT IS STAMPED, SIGNED, AND DATED BELOW
1 2 3 4 5 6
2017-07-20
8/22/2
017 7
:13:33
PM
C:\U
sers\
ambe
r\Doc
umen
ts\15
13_C
OF_C
ivic_
R17_
ambe
r.rvt
E504
ELECTRICAL DETAILS
1513
6/26
/201
7
FARM
ING
TON
CIV
IC C
ENTE
R R
ENO
VATI
ON
S &
EXPA
NSIO
N
200
W.
ARRIN
GTO
N,
FARM
ING
TON
, N
M 8
7401
CIT
Y O
F FA
RM
ING
TON
NB
TC
FIRE RISER DIAGRAMD5
EMERGENCY 2-WAY COMM. DIAGRAMC5
CORD DROP DETAILA6
SECURITY CAMERA RISER DIAGRAMB5
POLE BASE ELECTRICAL DETAILC1
NOTES:1. The circuit lengths shown are for calculation purposes only.They shall not be used for contractor takeoffs or bidding.
2. Contractor shall notify engineer of any field condition that results in a change of20% or greater circuit distance.
SITE CIRCUIT CONDUCTOR SCHEDULE
PANEL CIRCUIT NAME CONDUCTORS INCLUDE 0-10V DIMMINGCONDUCTORS (2 # 16 CU)
CONTROLLED BYCENTRAL PANEL
EST.LENGTH CB SIZE VOLTAGE
LAF 1,3,5 Food Truck Pedestals East # 4/0 CU + #2 CU EGC No No 441' 100 A 208 V
LAF 2 Fountain Pump (GFCI) # 10 CU + # 10 CU EGC No No 34' 25 A 120 V
LAF 6 Holiday Lgt Recept Bldg # 10 CU + # 10 CU EGC No Yes 198' 20 A 120 V
LAF 7,9,11 Food Truck Pedestals East # 1/0 CU + # 4 CU EGC No No 291' 60 A 208 V
LAF 8 Holiday Lgt Recept Center # 8 CU + # 8 CU EGC No Yes 486' 20 A 120 V
LAF 10 Holiday Lgt Recept East # 8 CU + # 8 CU EGC No Yes 528' 20 A 120 V
LAF 12 Irrigation Controller # 12 CU + # 12 CU EGC No No 148' 20 A 120 V
LAF 13,15,17 Company Switch CS3 # 3 CU + # 6 CU EGC No No 187' 60 A 208 V
LAF 14 Hotbox # 8 CU + # 8 CU EGC No No 184' 20 A 120 V
LAF 16 Vendor Power # 4 CU + # 4 CU EGC No No 295' 20 A 120 V
LAF 18 Vendor Power # 6 CU + # 6 CU EGC No No 182' 20 A 120 V
LAF 19,21,23 RV Pedestal # 8 CU + # 8 CU EGC No No 77' 50 A 208 V
LAF 20 Vendor Power # 4 CU + # 4 CU EGC No No 246' 20 A 120 V
LAF 22 Vendor Power # 4 CU + # 4 CU EGC No No 206' 20 A 120 V
LAF 24 Vendor Power # 6 CU + # 6 CU EGC No No 194' 20 A 120 V
LAF 25,27 Bollard Lights East # 12 CU + # 12 CU EGC No Yes 325' 20 A 208 V
LAF 29,31 Pole Lights East # 8 CU + # 8 CU EGC Yes Yes 478' 20 A 208 V
LAF 33,35 Pole Lights Center # 8 CU + # 8 CU EGC Yes Yes 484' 20 A 208 V
LAF 37,39 Trellis Lighting East (Alternate) # 12 CU + # 12 CU EGC Yes Yes 276' 20 A 208 V
D 1,3,5 Food Truck Pedestals West # 2/0 CU + # 4 CU EGC No No 301' 100 A 208 V
D 2 Holiday Lgt Recept West # 8 CU + # 8 CU EGC No Yes 410' 20 A 120 V
D 4 Holiday Lgt Recept Bldg # 10 CU + # 10 CU EGC No Yes 104' 20 A 120 V
D 6 Holiday Lgt Recept West # 8 CU + # 8 CU EGC No Yes 166' 20 A 120 V
D 7,9 Pole Lights West # 8 CU + # 8 CU EGC Yes Yes 583' 20 A 208 V
D 8 Vendor Power # 6 CU + # 6 CU EGC No No 162' 20 A 120 V
D 10 Vendor Power # 6 CU + # 6 CU EGC No No 197' 20 A 120 V
D 11,13 Bollard Lights West # 12 CU + # 12 CU EGC No Yes 626' 20 A 208 V
D 12 Vendor Power # 8 CU + # 8 CU EGC No No 113' 20 A 120 V
D 14 Vendor Power # 4 CU + # 4 CU EGC No No 283' 20 A 120 V
D 15,17 Trellis Lighting West (Alternate) # 12 CU + # 12 CU EGC Yes Yes 276' 20 A 208 V
D 16 Monument Sign Ckt #1 # 8 CU + # 8 CU EGC No No 156' 20 A 120 V
D 18 Monument Sign Ckt #2 # 8 CU + # 8 CU EGC No No 156' 20 A 120 V
D 19 Sculpture Flood Lighting # 12 CU + # 12 CU EGC No Yes 131' 20 A 120 V
D 20 Monument Sign Ckt #3 # 8 CU + # 8 CU EGC No No 156' 20 A 120 V
D 22 Monument Sign Ckt #4 # 8 CU + # 8 CU EGC No No 156' 20 A 120 V
Mar
kD
ate
Des
crip
tion
18/
24/1
7AD
DEN
DU
M 1
SPLASH PAD GROUNDING AND BONDING DETAIL1
1
1
463
TUR
NE R
DR
, SU
ITE
104A
DU
RAN
GO
, CO
813
03PH
ON
E : 9
70-3
8 5-1
570
FAX:
970
-385
-156
9
ME C
HAN
ICAL
, ELE
CTR
ICA L
& EN
V IR
ON
ME N
TAL
ENG
INEE
RIN
G IN
C.
A
B
C
D
E
A
B
C
D
E
1 2 3 4 5 6
DRAWN BY:
CHECKED BY:
PROJECT NO:
GREER-STAFFORD/SJCF, INC.C
SHEET TITLE
DRAWING SHEET
ISSU
E:
THIS DRAWING IS INCOMPLETE AND NOT TO BE USED FOR CONSTRUCTION UNLESS IT IS STAMPED, SIGNED, AND DATED BELOW
1 2 3 4 5 6
2017-07-20
8/22/2
017 7
:13:41
PM
C:\U
sers\
ambe
r\Doc
umen
ts\15
13_C
OF_C
ivic_
R17_
ambe
r.rvt
E601
LIGHT FIXTURESCHEDULES
1513
6/26
/201
7
FARM
ING
TON
CIV
IC C
ENTE
R R
ENO
VATI
ON
S &
EXPA
NSIO
N
200
W.
ARRIN
GTO
N,
FARM
ING
TON
, N
M 8
7401
CIT
Y O
F FA
RM
ING
TON
AW/NB
AW
NOTES:1. Unless otherwise noted, all fixtures shall be 35K CCT and shall have minimum 80 CRI.2. Unless otherwise noted, all fixtures shall have universal voltage (120-277) drivers.3. Unless otherwise noted, all heights shown are to bottom of fixture.
4. Proposed substitutions must be APPROVED PRIOR TO BIDDING, meet all requirements listed here, and have IES files available. Refer to specification text for detailed requirements for substitutionrequests.
LIGHTING FIXTURE SCHEDULE
TYPE DESCRIPTION BASIS OF DESIGN SPEC-MAKE BASIS OF DESIGN SPEC - MODEL PRE-APPROVED ALTERNATE
SPEC 1 - MAKE PRE-APPROVED ALTERNATE SPEC 1 - MODEL MOUNTING HEIGHT LAMP LOAD LUMENS OPTIC NOTES
NO SUBSTITUTION ALLOWED FOR THESE FIXTURES (MUST MATCH EXISTING FIXTURES):
A FLUORESCENT 4'X4" LENSED LINEAR, MATCHING EXISTING.LIGHTED 90 DEG CORNERS. PINNACLE E4SCH-1T5-G1-UNV-1C-W NONE NONE RECESSED, GRID CEILING F54WT5/830/ECO 54 VA - DIFFUSE 0-10V DIMMING
B 2X2 TROFFER, MATCHING EXISTING GE ET22-A1-0AV-WHITE w/67657 NONE NONE RECESSED,GYPSUM CEILING LED 42 VA 3,500 DIFFUSE 0-10V DIMMING
C1~20'FT COLOR CHANGING LED COVE MATCHING EXSITING.MOUNTING TRACK, ELEC DRIVER, DMX CONTROL, 2" LEDSPACING
TOKISTAR TRI-50-RGB, TRI-MT, LDR8-80, LC-3CH-DMX NONE NONE COVE SHELF CEILING LED 40 VA 17 / FT PEAK DIFFUSE DMX CONTROL. PROVIDE QUANTITY OF DRIVERS AND CONTROLLERS AS NEEDED FORCOPLETE AND FUNCTIONAL SYSTEM OF LENGTH INDICATED.
C2~115'FT COLOR CHANGING LED COVE MATCHING EXSITING.MOUNTING TRACK, ELEC DRIVER, DMX CONTROL, 2" LEDSPACING
TOKISTAR TRI-50-RGB, TRI-MT, LDR8-80, LC-3CH-DMX NONE NONE COVE SHELF CEILING LED 230 VA 17 / FT PEAK DIFFUSE DMX CONTROL. PROVIDE QUANTITY OF DRIVERS AND CONTROLLERS AS NEEDED FORCOPLETE AND FUNCTIONAL SYSTEM OF LENGTH INDICATED.
C3~128'FT COLOR CHANGING LED COVE MATCHING EXSITING.MOUNTING TRACK, ELEC DRIVER, DMX CONTROL, 2" LEDSPACING
TOKISTAR TRI-50-RGB, TRI-MT, LDR8-80, LC-3CH-DMX NONE NONE COVE SHELF CEILING LED 256 VA 17 / FT PEAK DIFFUSE DMX CONTROL. PROVIDE QUANTITY OF DRIVERS AND CONTROLLERS AS NEEDED FORCOPLETE AND FUNCTIONAL SYSTEM OF LENGTH INDICATED.
D LARGE DECORATIVE CHANDELIER MATCHING EXISTING SEE NOTE SEE NOTE NONE NONE PENDANT MATCH EXISTING INCAND. 600 VA N/A DIFFUSECUSTOM CHANDELIER MATCHING EXISTING. INCLUDE ALLOWANCE FOR THIS FIXTURE(REFER TO SPEC SECTION 01 21 00-1.06 ALLOWANCES SCHEDULE). OWNER WILLPROVIDE SUPPLIER INFORMATION AFTER PROJECT IS AWARDED.
EX2 EXIT SIGN, MATCHING EXISTING, BLACK ALUMINUM,INTEGRAL BATTERY MCPHILBEN ER55LD3G NONE NONE UNIVERSAL UNIVERSAL LED 5 VA N/A N/A
SUBSTITUTION ALLOWED FOR THESE FIXTURES:
ER EXTERIOR REMOTE LIGHT HEAD POWERED BY TYPE EXR OREXLR COMPASS CORS LITHONIA ELA QWP L0309 WALL 9' AFG LED 0 VA N/A DIFFUSE
EX EXIT SIGN, RED ON WHITE, INTEGRAL BATTERY COMPASS CCR LITHONIA EXR LED EL M6 UNIVERSAL UNIVERSAL LED 5 VA N/A N/A
EXL EXIT SIGN WITH LIGHTS, RED ON WHITE, INTEGRAL BATTERY COMPASS CER LITHONIA EXR LED EL M6 UNIVERSAL UNIVERSAL LED 5 VA N/A N/A
EXLR EXIT SIGN WITH LIGHTS AND REMOTE CAPACITY, RED ONWHITE, INTEGRAL BATTERY COMPASS CCRRC LITHONIA LHQM LED R HO UNIVERSAL UNIVERSAL LED 5 VA N/A N/A
EXR EXIT SIGN WITH REMOTE CAPACITY, RED ON WHITE,INTEGRAL BATTERY COMPASS CERRC LITHONIA LHQM LED R HO R0 UNIVERSAL UNIVERSAL LED 5 VA N/A N/A
F2 DECORATIVE VANITY FIXTURE, 2FT TERON BT24-L20.6-120-277V-TE600-FINISH-WLL-35K BROWNLEE 5461 24 FINISH H16LED 35K WALL 7' AFF LED 20 VA 2,000 DIFFUSE
F4 DECORATIVE VANITY FIXTURE, 4FT TERON BT48-L41.2.0-120-277V-TE350-FINISH-WLL-35K BROWNLEE 5461 48 FINISH H32LED 35K WALL 7' AFF LED 42 VA 4,000 DIFFUSE
G1 DISC LIGHT, 1" H X 10" DIAM, WHITE DALS CFLEDR10-WH SURFACE CEILING LED 11 VA 1,000 DIFFUSE WET LOCATION. 120 VOLT ACCEPTABLE.
G2 SURFACE DISC LIGHT, 2" H X 1 FT DIAM. TMS AR901-12-19LED-35K-120-FINISH-SD-DIML SURFACE CEILING LED 19 VA 1,400 DIFFUSE 120 VOLT ACCEPTABLE.
G2E SURFACE DISC LIGHT, 2" H X 1 FT DIAM., WITH REMOTEBATTERY TMS AR901-12-19LED-35K-120-FINISH-SD-DIML-EM
R SURFACE CEILING LED 19 VA 1,400 DIFFUSE MOUNT BATTERY ABOVE ACCESSIBLE CEILING WITHIN 20 FT
H1 LENSED STRIP, LOW WATTS COLUMBIA LCL4-35LW-EU LITHONIA ZL1D L48 SMR 3000LM FST MVOLT 35K 80CRI WH SURFACE CEILING LED 19 VA 2,500 DIFFUSE
H1E LENSED STRIP, LOW WATTS, EM BATTERY COLUMBIA LCL4-35LW-EU-ELL14 LITHONIA ZL1D L48 SMR 3000LM FST MVOLT 35K 80CRI WHE7W SURFACE CEILING LED 19 VA 2,500 DIFFUSE
H2 LENSED STRIP, MEDIUM OUTPUT COLUMBIA LCL4-35ML-EU LITHONIA ZL1D L48 SMR 5000LM FST MVOLT 35K 80CRI WH SURFACE CEILING LED 42 VA 5,000 DIFFUSE
H2E LENSED STRIP, MEDIUM OUTPUT, EM BATTERY COLUMBIA LCL4-35ML-EU-ELL14 LITHONIA ZL1D L48 SMR 5000LM FST MVOLT 35K 80CRI WHE7W SURFACE CEILING LED 42 VA 5,000 DIFFUSE
H3 LENSED STRIP, HIGH OUTPUT COLUMBIA LCL4-35HL-EU + CSHC LITHONIA ZL1D L48 SMR 7000LM FST MVOLT 35K 80CRI WHHC36 SUSPENDED CEILING LED 52 VA 6,000 DIFFUSE
HWE 2FT LENSED STRIP, WET LOCATION, BATTERY COLUMBIA LXEM2-35LW-RFA-EU-ELL14 LITHONIA DMW2 L24 4000LM AFL WD VOLTAGE GZ1 35K 80CRIPS1050 SURFACE SURFACE LED 29 VA 4,000 DIFFUSE
INV-1 MINI INVERTER, 2X4 GRID CEILING MOUNT DUAL LITE LG125-T-I LITHONIA EAC ISSM 125 120/277 RGM RECESSED, GRID CEILING LED 23 VA N/A N/A MOUNT IN CEILING GRID AND CONNECT TO EXTERIOR FIXTURES SHOWN ON PLAN.
INV-2 FLOOR MOUNTED INVERTER FOR THEATER EMERGENCYLIGHTING DUAL LITE DLS-1500-120-A-20-03 FLOOR FLOOR - 600 VA - N/A SEE ONE-LINE DIAGRAM, SHEET E503
J1 1X4 TROFFER, VERY LOW WATTS, VOLUMETRIC,RECTILINEAR LENS COLUMBIA LCAT14-35VWG-R-EDU LITHONIA BLT4 30L SDSM EZ1 LP835 RECESSED, GRID CEILING LED 28 VA 3,000 DIFFUSE
J1E 1X4 TROFFER, VERY LOW WATTS, VOLUMETRIC,RECTILINEAR LENS, EM BATTERY COLUMBIA LCAT14-35VWG-R-EDU-ELL14 LITHONIA BLT4 30L SDSM EZ1 LP835 EL14L RECESSED, GRID CEILING LED 28 VA 3,000 DIFFUSE
J1S SAME AS A1 BUT WITH SURFACE MOUNTING COLUMBIA LCAT14-35VWSM-R-EDU LITHONIA BLTX4 30L SDSM EZ1 LP835 RECESSED, GRID CEILING LED 28 VA 3,000 DIFFUSE
J2 2X2 TROFFER, LOW WATTS, VOLUMETRIC, RECTILINEARLENS COLUMBIA LCAT22-35LWG-R-EDU LITHONIA 2BLT2 33L SDSM EZ1 LP835 RECESSED, GRID CEILING LED 23 VA 2,700 DIFFUSE
J2E 2X2 TROFFER, LOW WATTS, VOLUMETRIC, RECTILINEARLENS, EM BATTERY COLUMBIA LCAT22-35LWG-R-EDU-ELL14 LITHONIA 2BLT2 33L SDSM EZ1 LP835 EL14L RECESSED, GRID CEILING LED 23 VA 2,700 DIFFUSE
J3 2X2 TROFFER, VERY HIGH OUTPUT, VOLUMETRIC,RECTILINEAR LENS COLUMBIA LCAT22-35VLG-R-EDU LITHONIA 2BLT2 48LHE SDSM EZ1 LP835 RECESSED, GRID CEILING LED 39 VA 4,300 DIFFUSE
J3E 2X2 TROFFER, VERY HIGH OUTPUT, VOLUMETRIC,RECTILINEAR LENS, EM BATTERY COLUMBIA LCAT22-35VLG-R-EDU-ELL14 LITHONIA 2BLT2 48LHE SDSM EZ1 LP835 EL14L RECESSED, GRID CEILING LED 39 VA 4,300 DIFFUSE
J3F SAME AS A3 BUT WITH FLANGE KIT COLUMBIA LCAT22-35VLG-R-EDU-FK22 LITHONIA 2BLT2 48LHE SDSM EZ1 LP835 DGA22 RECESSED,GYPSUM CEILING LED 39 VA 4,300 DIFFUSE
J4 2X4 TROFFER, LOW WATTS, VOLUMETRIC, RECTILINEARLENS COLUMBIA LCAT24-35LWG-R-EDU LITHONIA 2BLT4 48L SDSM EZ1 LP835 RECESSED, GRID CEILING LED 36 VA 4,300 DIFFUSE
J4E 2X4 TROFFER, LOW WATTS, VOLUMETRIC, RECTILINEARLENS, EM BATTERY COLUMBIA LCAT24-35LWG-R-EDU-ELL14 LITHONIA 2BLT4 48L SDSM EZ1 LP835 EL14L RECESSED, GRID CEILING LED 36 VA 4,300 DIFFUSE
K 1X4 KITCHEN TROFFER, GASKETED, WITH FLAT LENSINVERTED FOR EASY CLEANING COLUMBIA LJT14-35HLG-FS-A19INVERTED-EDU-G3 LITHONIA GTL 4 48L A19V EZ1 LP835 ABC RECESSED, GRID CEILING LED 45 VA 4,500 DIFFUSE
KE 1X4 KITCHEN TROFFER, GASKETED, WITH FLAT LENSINVERTED FOR EASY CLEANING, EM BATTERY COLUMBIA LJT14-35HLG-FS-A19INVERTED-EDU-G3-ELLI
4 LITHONIA GTL 4 48L A19V EZ1 LP835 ABC EL14L RECESSED, GRID CEILING LED 45 VA 4,500 DIFFUSE
L DECORATIVE UP/DOWN SCONCE AT STAIRWELLS TMS TIA20-44LED-35K-120-FINISH-OP-DIML WALL MATCH EXISTING LED 44 VA 2,000 UP/DOWN
M SURFACE MOUNT CYLINDER WITH FROSTED GLASS LENS SPECTRUM SPC1203LEDGV-37L-35K-DS10X-8200GV-SG-SO-1FGR-SM-PT STONE CL466 FR WH LED SURFACE CEILING LED 23 VA 3,000 DOWN
N WALL MOUNT MAKEUP LIGHT, INCENDESCENT ONLY,CHROME FINISH PROGRESS P3300-15 TRANS GLOBE LYRIC 48” 3208PC WALL/MIRROR CENTER ON MIRROR INCANDESCENT 200 VA - DIFFUSE/FORWA
RDMOUNT IN WALL MIRROR. REFER TO ARCH ELEVATION. PROVIDE LAMPS, + 20% SPARELAMPS.
P2 POST-TOP POLE FIXTURE, TYPE 2 DISTRIBUTION, WITHGLARE-REDUCING LENS STERNBERG PT-SL660-SV1-84L35K-T2-MDL05-UWH +
RSA10A500-2401-5-(2)GFI-UWH 10' POLE + 2' BASE 14' TOTAL (FIXTURE IS2' TALL) LED 140 VA 10,300 TYPE 2 0-10V DIMMING, TWO RECEPTACLES IN POLE
P4 POST-TOP POLE FIXTURE, TYPE 4 DISTRIBUTION, WITHGLARE-REDUCING LENS STERNBERG PT-SL660-SV1-84L35K-T4-MDL05-UWH +
RSA10A500-2401-5-(2)GFI-UWH 10' POLE + 2' BASE 14' TOTAL (FIXTURE IS2' TALL) LED 140 VA 10,300 TYPE 4 0-10V DIMMING
PB POST-TOP BOLLARD MATCHING POLE FIXTURES STERNBERG BL-4-SL360-SV1-26L35K-T4-F-MDL03-UWH BOLLARD 4' LED 30 VA 2,200 TYPE 4 WIRE FOR 0-10V DIMMING
Q1 1 FT RUN OF THEATER AISLE LIGHT, LEDS 4" ON CENTER,AMBER, WALL MOUNT PRIMUS PL-PWL-4-A-1 FT WALL 18" AFF LED 1 VA N/A N/A
Q3 3 FT RUN OF THEATER AISLE LIGHT, LEDS 4" ON CENTER,AMBER, WALL MOUNT PRIMUS PL-PWL-4-A-3 FT WALL 18" AFF LED 3 VA N/A N/A
R22 22 FT RUN OF THEATER AISLE LIGHT, LEDS 4" ON CENTER,AMBER, CARPET-TO-WALL MOUNT PRIMUS PL-C/W-4-A-22 FT FLOOR FLOOR LED 22 VA N/A N/A LENGTHS SHOWN ARE SLIGHTLY LONGER THAN REQUIRED. FIXTURE IS FIELD CUTTABLE
TO EXACT LENGTH.
R24 24 FT RUN OF THEATER AISLE LIGHT, LEDS 4" ON CENTER,AMBER, CARPET-TO-FLOOR MOUNT PRIMUS PL-C/F-4-A-24 FT FLOOR FLOOR LED 24 VA N/A N/A LENGTHS SHOWN ARE SLIGHTLY LONGER THAN REQUIRED. FIXTURE IS FIELD CUTTABLE
TO EXACT LENGTH.
R26 26 FT RUN OF THEATER AISLE LIGHT, LEDS 4" ON CENTER,AMBER, CARPET-TO-FLOOR MOUNT PRIMUS PL-C/F-4-A-26 FT FLOOR FLOOR LED 26 VA N/A N/A LENGTHS SHOWN ARE SLIGHTLY LONGER THAN REQUIRED. FIXTURE IS FIELD CUTTABLE
TO EXACT LENGTH.
R41 41 FT RUN OF THEATER AISLE LIGHT, LEDS 4" ON CENTER,AMBER, CARPET-TO-FLOOR MOUNT PRIMUS PL-C/F-4-A-41 FT FLOOR FLOOR LED 41 VA N/A N/A LENGTHS SHOWN ARE SLIGHTLY LONGER THAN REQUIRED. FIXTURE IS FIELD CUTTABLE
TO EXACT LENGTH.
S4 4 FT THEATER STAIR EDGE LIGHT, LEDS 4" ON CENTER,AMBER PRIMUS PL-LSL-4-A-4 FT STAIR TREAD FLOOR LED 4 VA N/A N/A PROVIDE FIXTURE MANUFACTURER'S SURFACE WIREWAY AND ENDCAPS AS NEEDED
FOR COMPLETE AND FUNCTIONAL SYSTEM.
T STRAIGHT SURFACE MOUNT TRACK, AIMABLE HEADS, WIDEBEAM SPREAD, 90+ CRI ELCO ET756DW + TRACK + 2.5A LIMITER TRACK CEILING LED 15 VA 1,000 ADJUSTABLE 120 VOLT ACCEPTABLE. INCLUDE SURFACE MOUNTED LINE VOLTAGE TRACK PER PLAN,
PLUS ONE 2.5 AMP CURRENT LIMITER PER RUN
U 6" RECESSED DOWNLIGHT, DMX CONTROL, BLACK BAFFLE PRESCOLITE LF6SL11L-120-DMX-6LFSL-11L-30K-BNCTB-DL JUNO LRM6 13LM 30K MVOLT G3 80CRI DMXR BAF BL RECESSED, GRID CEILING LED 14 VA 1,000 DOWN CONTROL BY THEATRICAL DMX SYSTEM.
V1 CYLINDER, LOWER OUTPUT, DMX CONTROL, WIDE BEAMSPREAD, DIFFUSING LENS, 30K METEOR CSS-30-308-UNV-DMX-WD-BLK-AD10-DF GOTHAM ICO CYL 30/20 6AR LSS 70D MVOLT EDXB ACC DBL SUSPENDED MATCH EXISTING LED 30 VA 2,000 WIDE FLOOD
V2 CYLINDER, MEDIUM OUTPUT, DMX CONTROL, WIDE BEAMSPREAD, DIFFUSING LENS, 30K METEOR CSS-50-308-UNV-DMX-WD-BLK-AD10-DF GOTHAM ICO CYL 30/40 6AR LSS 70D MVOLT EDXB ACC DBL SUSPENDED MATCH EXISTING LED 50 VA 4,000 WIDE FLOOD
V3 CYLINDER, HIGH OUTPUT, DMX CONTROL, WIDE BEAMSPREAD, DIFFUSING LENS, 30K METEOR CSS-90-308-UNV-DMX-WD-BLK-AD10-DF GOTHAM ICO CYL 30/70 6AR LSS 70D MVOLT EDXB ACC DBL SUSPENDED MATCH EXISTING LED 90 VA 7,000 WIDE FLOOD
W WALL SCONCE WITH GLARE REDUCING LENS STERNBERG 1W-SL270-SV1-36L35T3R-MDL03/UWH EXTERIOR WALL MATCH EXISTING LED 43 VA 3,500 TYPE 3
WE WALL SCONCE WITH GLARE REDUCING LENS, EM BATTERY STERNBERG 1W-SL270-SV1-36L35T3R-MDL03-EM/UWH EXTERIOR WALL MATCH EXISTING LED 43 VA 3,500 TYPE 3
Y NARROW LINEAR LENSED, WET LOCATION AXIS WBWLED-500-80-35-S-4-W-UNV-DP-1 PAL ML3WL D MO K35 4 W LOH F01M EF 120 DIM1 WALL SURFACE TRELLIS LED 22 VA 2,000 DIFFUSE
Z MINI AIMABLE FLOODLIGHT FOR TREE SCULPTURE HUBBELL MBUL-1L3K-1 FOCUS DL-21-BLT/FA-24/BRS / INCLUDE LED LAMPS GROUND,CONCRETE GROUND LED 13 VA 1,000 FLOOD, AIMABLE
Mar
kD
ate
Des
crip
tion
18/
24/1
7AD
DEN
DU
M 1
EXISTING LTG FIXTURE SCHEDULETYPE DESCRIPTION MOUNTING LAMP
X12.A 11"X11" GLASS LENSED DOWNLIGHT RECESSED - GYP.
X12.B1 2'X2' RECESSED LENSED TROFFER, TO BE REINSTALLED RECESSED - GYP.
X74.A1 2'X4'PENDANT TROFFER PENDANT 4x34W T12
X74.B1 EXISTING 1X4 RECESSED TROFFER PENDANT/SURFACE 2x34W T12
X74.EM EXISTING EMERGENCY LIGHT WALL
X74.F 4' FLUORESCENT STRIP PENDANT/SURFACE 2x34W T12
X74.FE 4' FLUORESCENT STRIP PENDANT/SURFACE 2x34W T12
X74.G 1'X4' PENDANT PENDANT 2x34W T12
X74.H 8" RECESSED DOWNLIGHT RECESSED
X74.J 8" RECESSED DOWNLIGHT RECESSED
X74.K PENDANT CYLINDER PENDANT/SURFACE
X74.K1 PENDANT CYLINDER PENDANT/SURFACE
X74.KA EXISTING WALL MOUNTED STEP LIGHT IN CORRIDOR BELOWSEATING RECESSED WALL
X74.M PENDANT/RECESSED CYLINDER PENDANT
X74.P TRACK LIGHT SURFACE
X74.P1 PENDANT CYLINDER PENDANT/SURFACE
X74.Q PENDANT CYLINDER PENDANT
X74.R 4' FLUORESCENT WALL MOUNT WALL 2x34W T12
X74.U CATWALK LIGHTING PENDANT
X74.V UP/DOWN CYLINDER WALL
X74.Y PENDANT CYLINDER PENDANT
X74.Z WALL MOUNT VANITY STRIP WALL/MIRROR 8x 40W
X74.Z 8" RECESSED DOWNLIGHT
X76.1 2'X4' RECESSED LENSED TROFFER RECESSED - GRID 4 x 32W T12
X76.2 2'X2' RECESSED LENSED TROFFER RECESSED - GRID 2 x 32W T8
X76.2E 2'X2' RECESSED LENSED TROFFER W/ EMERG. RECESSED - GRID 2 x 32W T8
X76.4 PENDANT WALLWASH SURFACE - STRUCTURE
X76.5 PENDANT CYLINDER SURFACE - STRUCTURE
X76.6 SURFACE MOUNT LENSED 8"X8' SURFACE - GRID OR PENDANT 2 x 75W F96T12
X76.7 SURFACE MOUNT LENSED 8"X8' PENDANT 2 x 75W F96T12
x76.8 SINGLE BULB WALL
x76.10 1' RECESSED DOWNLIGHT, WET LISTED RECESSED
X76.11 SURFACE MOUNT LENSED 8"X8' WET LISTED SURFACE - GRID 4x34W T12
X76.11E SURFACE MOUNT LENSED 8"X8' WET LISTED SURFACE - GRID 4x34W T12
X76.13 8" RECESSED DOWNLIGHT
X76.15 11"X11" GLASS LENSED DOWNLIGHT RECESSED - GRID
X76.EX
X76.P TRACK LIGHT SURFACE
X.1 SURFACE MOUNT 1'X4' LENSED SURFACE 2x34W T12
XS EXISTING GLOBE STYLE POST-TOP POLE FIXTURE, TO BE REMOVEDE
XW EXTERIOR WALL PACK TO BE REMOVED
1
1