120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 5 Penn Plaza, Suite 1972 ● New York, New York 10001 ● tel: 212-952-7300
Prepared For:
State of New Jersey
Department of Transportation
1035 Parkway Avenue
P.O. Box 600
Trenton, NJ 08625-0600
Prepared By:
Environmental Connection, Inc.
120 North Warren Street
Trenton, New Jersey 08608
June 21, 2018
EC Project #: 18163-01
REPORT
Environmental Assessment
New Jersey Department of Transportation
Jersey City Maintenance Yard
401 Lincoln Highway
Jersey City, New Jersey 07306
New Jersey Department of Transportation
Jersey City Maintenance Yard
Environmental Assessment
Page 1 of 8
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 5 Penn Plaza, Suite 1972 ● New York, New York 10001 ● tel: 212-952-7300
TABLE OF CONTENTS
SECTION 1.0 EXECUTIVE SUMMARY ............................................................................... 2
SECTION 2.0 ASBESTOS CONTAINING MATERIAL INSPECTION ............................... 2
SECTION 3.0 LEAD BASED PAINT INSPECTION ............................................................. 4
SECTION 4.0 POLYCHLORINATED BIPHENYL INSPECTION ....................................... 5
SECTION 5.0 PROJECT LIMITATIONS/DISCLAIMERS .................................................... 7
SECTION 6.0 CONCLUSIONS AND RECOMMENDATIONS ............................................ 8
APPENDIX I ASBESTOS ANALYTICAL REPORTS AND CHAIN OF CUSTODY
APPENDIX II PHOTOGRAPHS
APPENDIX III LEAD BASED PAINT INSPECTION DATA
APPENDIX IV POLYCHLORINATED BIPHENYL ANALYTICAL REPORTS AND CHAIN OF
CUSTODY
APPENDIX V CERTIFICATIONS/ACCREDITATIONS
New Jersey Department of Transportation
Jersey City Maintenance Yard
Environmental Assessment
Page 2 of 8
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 5 Penn Plaza, Suite 1972 ● New York, New York 10001 ● tel: 212-952-7300
SECTION 1.0 EXECUTIVE SUMMARY
Environmental Connection, Inc., (EC) was contracted by The New Jersey Department of Transportation,
(NJDOT) to perform an environmental assessment of multiple structures at the Jersey City Maintenance
Yard lot located at 401 Lincoln Highway in Jersey City, New Jersey. The goal of the assessment was to
identify Asbestos Containing Materials (ACMs), Lead-Based Paints (LBP) and Polychlorinated Biphenyl
(PCB) containing caulks/glazings present at the site. The assessment was performed on May 29, 2018, by
Mr. Dominick Dercole, Ms. Linda Kelly and Mr. Brian Brill, all of whom are United States
Environmental Protection Agency (USEPA) accredited Asbestos Building Inspectors. Mr. Dercole and
Ms. Kelly are State of New Jersey Department of Health licensed LBP Inspectors.
During the inspection, EC collected 25 samples of 12 suspect asbestos containing materials. Two (2) of
the materials sampled contained asbestos concentrations greater that 1% by weight. The asbestos
containing materials are listed below organized by building:
Building 1336
1. Caulk Associated with Window
Panel
2. Exterior Expansion Joint Caulk
The LBP inspection revealed seven (7) building components coated with LBP. Section 3.0 of this report
discusses the methodology and summarizes the results of the LBP inspection.
EC’s inspectors also collected five (5) samples of suspect PCB containing caulk and glazing. Analysis
revealed the caulking and glazing materials sampled to have “none detected” concentrations of PCBs.
Section 4.0 of this report summarizes the results of the PCB sampling.
The following sections detail the findings of our environmental assessment.
SECTION 2.0 ASBESTOS CONTAINING MATERIAL INSPECTION
Asbestos is a naturally occurring mineral categorized into two (2) groups, Serpentine and Amphibole. It
was utilized in more than 3,600 products for its fire resistance, tensile strength, inertness, and chemical
binding properties. The Serpentine group is comprised of Chrysotile asbestos, while the Amphibole group
consists of Amosite, Crocidolite, Tremolite, Anthophyllite, and other forms of asbestos.
The inspection for asbestos containing materials was performed in accordance with 40 CFR, Part 763,
AHERA/ASHARA, and encompassed accessible interior and exterior spaces. Samples of suspect
materials were collected in sufficient quantity as mandated by 40 CFR, Part 763.87(a). The samples were
submitted to EMSL Analytical, Inc., located in Cinnaminson, New Jersey. EMSL Analytical, Inc., is
accredited by the American Industrial Hygiene Association (AIHA) and participates in the National
Voluntary Laboratory Accreditation Program (NVLAP). Samples were analyzed utilizing Polarized Light
Microscopy (PLM) via EPA Method 600/R-93/116.
Sample analysis was also performed in accordance with Emergency Regulatory Adoptions to New Jersey
Administrative Codes (N.J.A.C.) 8:60 and 12:120, Volume 38, Issue 11, dated June 5, 2006. The
New Jersey Department of Transportation
Jersey City Maintenance Yard
Environmental Assessment
Page 3 of 8
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 5 Penn Plaza, Suite 1972 ● New York, New York 10001 ● tel: 212-952-7300
regulatory adoptions require the analysis of non-friable organically bound (NOB) suspect asbestos
containing materials via Transmission Electron Microscopy (TEM) analysis when PLM analysis yields
results of less than 1% asbestos by weight or “None Detected” for asbestos fibers. TEM uses electron
imaging to identify asbestos fibers at a higher magnification than possible via PLM.
Results for PLM and TEM analysis methods are reported in percentage by weight. According to the
USEPA, materials containing greater than 1% asbestos content by weight are classified as asbestos
containing materials. Materials containing <1% asbestos content by weight are classified as “Trace”
asbestos containing materials. Trace asbestos containing materials are not recognized by the USEPA but
are regulated by the United States Department of Labor Occupational Safety and Health Administration
(OSHA). The following tables summarize the analytical results.
Table 1 - Analytical Results Summary
New Jersey Department of Transportation
Jersey City Maintenance Yard – Office
LBAM Building ID: 1336
ID # Material PLM Results TEM Results
01 12”x12” Tan/Cream Floor Tile None Detected None Detected
01A Mastic Associated with 12”x12” Tan/Cream Floor Tile None Detected None Detected
02 Brown Cove Base None Detected None Detected
02A Mastic Associated with Brown Cove Base None Detected None Detected
03 2’x4’ Fissured Ceiling Tile None Detected N/A
04 Exterior Window Glazing None Detected 0.12%
Anthophyllite
05 Drywall None Detected N/A
05A Joint Compound Associated with Drywall None Detected N/A
06 Rubber Flooring Material None Detected N/A
06A Adhesive Associated with Rubber Flooring Material None Detected N/A
07 Exterior Expansion Joint Caulk None Detected 2.8%
Anthophyllite
08 Caulk Associated with Window Panel None Detected
1.5%
Anthophyllite
<0.30%
Chrysotile
09 Fire Caulk None Detected None Detected
010 Sheetrock Ceiling Panels None Detected N/A
011 Plaster Wall None Detected N/A
012 Exterior Window Casing Caulk None Detected 0.11%
Anthophyllite
N/A – Not Applicable
Laboratory analysis revealed two (2) materials that contain greater than 1% asbestos content by weight.
EC’s inspectors also quantified each suspect material as part of the inspection. The location and
approximate total quantity of identified asbestos containing materials is included in the following table.
New Jersey Department of Transportation
Jersey City Maintenance Yard
Environmental Assessment
Page 4 of 8
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 5 Penn Plaza, Suite 1972 ● New York, New York 10001 ● tel: 212-952-7300
Table 2 – Asbestos Containing Material Quantity
New Jersey Department of Transportation
Jersey City Maintenance Yard
Building Material Location Quantity
Building 1336 Caulk Associated with Window Panel Throughout 192 LF
Exterior Expansion Joint Caulk Exterior of Building 300 LF
SF – Square Feet | LF – Linear Feet
SECTION 3.0 LEAD BASED PAINT INSPECTION
Lead based paint (LBP) was used extensively before 1960 because it was more durable than other paints
available at the time. Due to the potential hazards of lead in paint, especially to children, lead-based paint
was banned in 1977.
The United States Department of Housing and Urban Development (HUD) and the USEPA define lead-
based paint as a coating which contains greater than 0.5% lead by weight or greater than 1.0 milligram of
lead per square centimeter (mg/cm2). The disturbance or dislocation of lead-based paint or lead containing
paint from building materials may cause lead dust to be released into the building`s atmosphere, thereby
creating a potential health hazard to workers and/or building occupants. To mitigate health hazards,
demolition and other construction related work is governed by the United States Department of Labor,
Occupational Safety and Health Administration, (OSHA). Under OSHA’s regulation, 29 CFR, Part
1926.62, “Lead in Construction Standard”, which defines construction work as work for alteration and/or
repair, including demolition or salvage of structures, removal or encapsulation of materials containing
lead.
EC utilized a portable X-Ray Fluorescence (XRF) device manufactured by RMD, Inc., of Watertown,
Massachusetts (RMD LPA-1 Analyzer Serial #1390), to detect the presence of lead within the paint films
and other finished surfaces (stains, varnishes, and shellacs). The device bombards the testing surface with
X-ray energy, generated by a radioactive source. The energy excites electrons in the testing surface
causing them to emit X-Ray energy. The X-Ray energy emitted by the electrons is analyzed by the XRF
device. Based on analysis of the X-ray energy emitted by the electrons, the device is able to determine the
presence and concentration of an element, in this case Lead, in the testing surface. Results are reported in
milligrams per square centimeter.
The USEPA Department of Housing and Urban Development (HUD) and New Jersey Administrative
Code (N.J.A.C.) 5:17, define any film which contains greater than 1.0 milligram of lead per square
centimeter (mg/cm2) as lead-based paint. EC performed the screening to characterize the surfaces and
building components within the structures of the maintenance yard and to determine if any coatings are
lead based. EC grouped similar building components with the like paint histories for testing purposes. The
results of the Lead-Based Paint Inspection are summarized in Table 3 below.
If the XRF analyzer indicated an inconclusive reading, or if a surface was unable to be screened utilizing
the XRF analyzer, a representative paint chip sample was collected. The paint was scraped from the
surface and collected in a non-electrostatic centrifugal tube. Each sample included all paint layers present
down to the surface of the substrate. The sample was then submitted to EMSL Analytical, Inc., of
Cinnaminson, New Jersey, for analysis via USEPA Method SW-846 7000B Flame Atomic Absorption
New Jersey Department of Transportation
Jersey City Maintenance Yard
Environmental Assessment
Page 5 of 8
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 5 Penn Plaza, Suite 1972 ● New York, New York 10001 ● tel: 212-952-7300
Spectrophotometry (AAS). EMSL is accredited by the American Industrial Hygiene Association (AIHA)
and participates in the National Lead Laboratory Accreditation Program (NLLAP).
Table 3– Lead-Based Paint
New Jersey Department of Transportation
Jersey City Maintenance Yard
Building Material
Building 1336
Exterior Garage Bay Area - Yellow Paint on Metal Bollard
Interior Garage Bay Area – Gray Paint on Metal Column
Interior Garage Bay Area - Red Paint on Metal Pipe
Interior Garage Bay, Red Paint on Metal Column
Interior Parts – Brown Paint on Metal Column
Interior Parts – Brown Paint on Metal Recessed Column
Interior Parts – Brown Paint on Metal Recessed Beam
The United States Department of Labor, Occupational Safety and Health Administration, (OSHA), does
not establish a threshold for lead containing material, meaning any surface coating with a detectable lead
concentration is defined as a “lead containing” material by OSHA. OSHA’s “Lead Safe Work Practices in
Construction” standard applies to any renovation activities that may impact materials classified as “lead
containing”. The lead paint chip sampling Chain of Custody and Certificate of Analysis are included in
Appendix III along with the XRF field inspection data sheets.
SECTION 4.0 POLYCHLORINATED BIPHENYL INSPECTION
PCBs were widely utilized between 1929 and 1977 in the United States as coolants and lubricants in
electrical equipment (i.e., capacitors, transformers, light ballasts), plasticizers, surface coatings, inks,
adhesives, flame retardants, pesticides, paints and carbonless duplicating paper, for their insulating
properties, chemical stability and relative non-flammability. PCB products were banned in the United
States in 1977. However, many PCB containing products remain in service to this day. The United States
Environmental Protection Agency (USEPA) has classified PCBs as a possible human carcinogen.
Recently, PCBs in caulk have become a prevalent regulatory issue within the United States, prompted by
studies conducted in Finland. The Finland investigation revealed a correlation between PCBs in caulk and
that of airborne PCBs and PCBs in blood of construction workers coming in contact with such materials.
The United States Environmental Protection Agency (USEPA) regulates disposal of caulking that
contains greater than 50 parts per million (ppm) under the Toxic Substances Control Act (TSCA) and
PCB regulations, 40 CFR, Part 761.
New Jersey Department of Transportation
Jersey City Maintenance Yard
Environmental Assessment
Page 6 of 8
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 5 Penn Plaza, Suite 1972 ● New York, New York 10001 ● tel: 212-952-7300
EC inspected the maintenance yard buildings for the presence of caulk and glazing suspected of
containing Polychlorinated Biphenyls (PCBs). EC collected samples of suspect PCB containing caulks
utilizing a razor knife. A minimum of one (1) gram of material was collected and placed directly into a
sampling jar. The sample was then labeled and submitted to the laboratory for analysis. Samples were
analyzed by EMSL Analytical, Inc., of Cinnaminson, New Jersey, in accordance with USEPA SW-846
Method 8082. PCB laboratory analytical reports and associated Chains of Custody documentation are
attached within Appendix IV.
None of the samples contained PCBs in concentrations greater than the 50 parts per million threshold
established by the USEPA. The reporting limit indicates the lowest detectable concentration for the
analysis method utilized. The reporting limit is determined by the original mass of the sample and is
therefore a dependent variable of the samples mass. Aroclor was the proprietary/commercial name given
to PCB containing mixtures. The mixtures were further defined by their unique composition. The four (4)
digit number following Aroclor refers to the composition of the mixture. The first two (2) digits denote
the number of carbon atoms present in the two phenyl rings. The second two (2) digits indicate the mass
percentage of Chlorine atoms in the mixture.
Table 7– Polychlorinated Biphenyl Analytical Results
New Jersey Department of Transportation
Jersey City Maintenance Yard
Material Analyte Reporting Limit Results
Building 1336 –
Exterior Window
Glazing
Aroclor 1016 0.89 mg/Kg ND
Aroclor 1221 0.89 mg/Kg ND
Aroclor 1232 0.89 mg/Kg ND
Aroclor 1242 0.89 mg/Kg ND
Aroclor 1248 0.89 mg/Kg ND
Aroclor 1254 0.89 mg/Kg ND
Aroclor 1260 0.89 mg/Kg ND
Aroclor 1262 0.89 mg/Kg ND
Aroclor 1268 0.89 mg/Kg ND
Building 1336 –
Exterior Window
Panel Caulk
Aroclor 1016 0.87 mg/Kg ND
Aroclor 1221 0.87 mg/Kg ND
Aroclor 1232 0.87 mg/Kg ND
Aroclor 1242 0.87 mg/Kg ND
Aroclor 1248 0.87 mg/Kg ND
Aroclor 1254 0.87 mg/Kg ND
Aroclor 1262 0.87 mg/Kg ND
Aroclor 1268 0.87 mg/Kg ND
Building 1336 –
Expansion Joint Caulk
Aroclor 1016 0.98 mg/Kg ND
Aroclor 1221 0.98 mg/Kg ND
Aroclor 1232 0.98 mg/Kg ND
Aroclor 1242 0.98 mg/Kg ND
Aroclor 1248 0.98 mg/Kg ND
Aroclor 1254 0.98 mg/Kg ND
Aroclor 1260 0.98 mg/Kg ND
Aroclor 1262 0.98 mg/Kg ND
New Jersey Department of Transportation
Jersey City Maintenance Yard
Environmental Assessment
Page 7 of 8
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 5 Penn Plaza, Suite 1972 ● New York, New York 10001 ● tel: 212-952-7300
Table 7– Polychlorinated Biphenyl Analytical Results
New Jersey Department of Transportation
Jersey City Maintenance Yard
Material Analyte Reporting Limit Results
Aroclor 1268 0.98 mg/Kg ND
Building 1336 - Door
Caulk
Aroclor 1016 1.0 mg/Kg ND
Aroclor 1221 1.0 mg/Kg ND
Aroclor 1232 1.0 mg/Kg ND
Aroclor 1242 1.0 mg/Kg ND
Aroclor 1248 1.0 mg/Kg ND
Aroclor 1254 1.0 mg/Kg ND
Aroclor 1260 1.0 mg/Kg ND
Aroclor 1262 1.0 mg/Kg ND
Aroclor 1268 1.0 mg/Kg ND
Building 1336 –
Exterior Window
Casing Caulk
Aroclor 1016 0.97 mg/Kg ND
Aroclor 1221 0.97 mg/Kg ND
Aroclor 1232 0.97 mg/Kg ND
Aroclor 1242 0.97 mg/Kg ND
Aroclor 1248 0.97 mg/Kg ND
Aroclor 1254 0.97 mg/Kg ND
Aroclor 1260 0.97 mg/Kg ND
Aroclor 1262 0.97 mg/Kg ND
Aroclor 1268 0.97 mg/Kg ND
ND – None Detected
SECTION 5.0 PROJECT LIMITATIONS/DISCLAIMERS
The Client should be aware that this survey did not incorporate destructive demolition to access hidden or
obscured ACM. Concealed asbestos-containing materials, such as vinyl asbestos floor tile which has been
overlaid with plywood, insulated piping lines in wall cavities, asbestos “nailcrete” below tongue and
groove flooring, ACM on pipes buried in concrete slabs and other potential ACM which is inaccessible
for sample extraction due to the physical coverage of the material were not sampled. EC does assure,
however, that due diligence was observed in performing sampling by generally recognized industry
sampling practices.
The Client should be advised that quantities referenced herein are estimates/approximations. Should a
previously unidentified suspect material be discovered during the demolition process that material should
be treated as an asbestos containing material until otherwise determined by appropriate sampling and
analysis, in accordance with 40 CFR, Part 763, and N.J.A.C. 8:60 and 12:120, inclusive of utilizing
USEPA accredited Asbestos Building Inspectors to collect the appropriate number of samples and an
AIHA accredited laboratory that is a NVLAP participant.
New Jersey Department of Transportation
Jersey City Maintenance Yard
Environmental Assessment
Page 8 of 8
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 5 Penn Plaza, Suite 1972 ● New York, New York 10001 ● tel: 212-952-7300
SECTION 6.0 CONCLUSIONS AND RECOMMENDATIONS
The environmental assessment performed at the NJDOT Jersey City Maintenance Yard on May 28, 2018,
revealed two (2) asbestos containing materials and seven (7) lead-based paint coated building
components. No PCB containing caulks or glazing were identified during the assessment. Based on the
results of our inspection, EC offers the following recommendations.
Employ a USEPA accredited Asbestos Project Designer to develop Plans and Specifications for
the asbestos abatement tailored to the scheduled renovations.
Removal of asbestos containing materials should be performed in accordance with 29 CFR
1926.1101 (the OSHA Standard for Asbestos in Construction). A New Jersey Department of
Labor licensed Asbestos Contractor must be employed to remove the asbestos containing
material(s), in accordance with N.J.A.C. 8:60 and 12:120. Please be advised that the types and
quantities of asbestos containing materials identified in this report do not fall under the
governance of N.J.A.C. 5:23-8, commonly referred to as Sub-Chapter 8. If the scope of work
changes, compliance requirements must be re-evaluated.
Perform air monitoring in accordance with federal and New Jersey requirements for asbestos
abatement in public buildings. EC recommends daily air monitoring during abatement activities
in addition to clearance air monitoring at the completion of abatement.
Should any previously unidentified suspect materials be discovered during the renovation
process, all work should cease until the materials are sampled by an accredited asbestos building
inspector.
Lead safe work practices specifications should be included in the renovation design documents.
As per OSHA, the Contractor is required to have a site-specific Lead Health and Safety Plan. The
Lead Health and Safety Plan shall include worker protection, engineering controls and
decontamination procedures, as outlined in 29 CFR, Part 1926.62. In addition, as required by
OSHA, individuals who will disturb lead-based paint shall be provided exposure monitoring by
the Contractor.
Should you have any questions or require additional information, please contact the undersigned at your
convenience.
Respectfully Submitted:
ENVIRONMENTAL CONNECTION, INC.
Linda M. Kelly
Project Manager
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 5 Penn Plaza, Suite 1972 ● New York, New York 10001 ● tel: 212-952-7300
APPENDIX I
ASBESTOS ANALYTICAL REPORTS AND CHAIN OF CUSTODY
EMSL Analytical, Inc.
1056 Stelton Road Piscataway, NJ 08854
Phone/Fax: (732) 981-0550 / (732) 981-0551http://www.EMSL.com / [email protected]
ENVI65051802212EMSL Order ID:
Customer ID:
Customer PO:
Project ID:
Attn:
Proj: 18163-01 / NJDOT- Jersey City Maintenance Yard / Bldg # 1336
Phone: (609) 392-4200
Fax:
Collected: 5/28/2018
Received: 5/29/2018
Analyzed: 5/31/2018
Dom Dercole
Environmental Connection, Inc.
120 North Warren Street
Trenton, NJ 08608
Summary Test Report for Asbestos Analysis in Accordance with N.J.A.C. 8:60 and 12:120
via EPA 600/R-93/116
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-000101DD052818
Kitchen - 12x12 Tan/Cream Spotted FT
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 0% 100%PLM Tan None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-000202DD052818
Men's Room - 12x12 Tan/Cream Spotted FT
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 0% 100%PLM Tan None Detected
5/31/2018 0.0% 100%TEM Grav. Reduction None DetectedTan
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-000301ADD052818
Kitchen - Mastic Assoc. w/ 12x12 Tan/Cream Spotted FT
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 <1% 100%PLM Black None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-000402ADD052818
Men's Room - Mastic Assoc. w/ 12x12 Tan/Cream Spotted FT
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 <1% 100%PLM Black None Detected
5/31/2018 0.0% 100%TEM Grav. Reduction None DetectedBlack
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-000503DD052818
Kitchen Storage -Brown Core Base
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 0% 100%PLM Brown None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-000604DD052818
Women's Room - Brown Core Base
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 0% 100%PLM Brown None Detected
5/31/2018 0.0% 100%TEM Grav. Reduction None DetectedBrown
Test Report:EPAMultiTests-7.32.2.D Printed: 5/31/2018 03:38PM Page 1 of 5
EMSL Analytical, Inc.
1056 Stelton Road Piscataway, NJ 08854
Phone/Fax: (732) 981-0550 / (732) 981-0551http://www.EMSL.com / [email protected]
ENVI65051802212EMSL Order ID:
Customer ID:
Customer PO:
Project ID:
Summary Test Report for Asbestos Analysis in Accordance with N.J.A.C. 8:60 and 12:120
via EPA 600/R-93/116
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-000703ADD052818
Kitchen Storage - Mastic Assoc. w/ Brown C.B
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 <1% 100%PLM Tan None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-000804ADD052818
Women's Room - Mastic Assoc. w/ Brown C.B
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 <1% 100%PLM Tan None Detected
5/31/2018 0.0% 100%TEM Grav. Reduction None DetectedTan
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-000905DD052818
Kitchen - 2x4 Fissured Ceiling Tile
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 52% 48%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-001006DD052818
Hallway Ramp - 2x4 Fissured Ceiling Tile
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 56% 44%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-001107DD052818
Office #3 - Exterior Window Glazing
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 <1% 100%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-001208DD052818
Office #2 - Exterior Window Glazing
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 <1% 100%PLM Gray None Detected
5/31/2018 0.0% 99.9% AnthophylliteTEM Grav. Reduction Gray 0.12%
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-001309DD052818
Kitchen Storage - Drywall
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 12% 88%PLM Gray/Tan None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0014010DD052818
Office #1 - Drywall
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 12% 88%PLM Gray/Tan None Detected
Test Report:EPAMultiTests-7.32.2.D Printed: 5/31/2018 03:38PM Page 2 of 5
EMSL Analytical, Inc.
1056 Stelton Road Piscataway, NJ 08854
Phone/Fax: (732) 981-0550 / (732) 981-0551http://www.EMSL.com / [email protected]
ENVI65051802212EMSL Order ID:
Customer ID:
Customer PO:
Project ID:
Summary Test Report for Asbestos Analysis in Accordance with N.J.A.C. 8:60 and 12:120
via EPA 600/R-93/116
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-001509ADD052818
Kitchen Storage - Joint Compound
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 <1% 100%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0016010ADD052818
Office #1 - Joint Compound
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 <1% 100%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0017011DD052818
Hallway @ Bath- Rubber Flooring
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 0% 100%PLM Tan None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0018012DD052818
Hallway @ Bath- Rubber Flooring
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 0% 100%PLM Tan None Detected
5/31/2018 0.0% 100%TEM Grav. Reduction None DetectedTan
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0019011ADD052818
Hallway @ Bath - Adhesive Assoc. w/ Rubber Flooring
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 <1% 100%PLM Yellow None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0020012ADD052818
Hallway @ Bath - Adhesive Assoc. w/ Rubber Flooring
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 <1% 100%PLM Yellow None Detected
5/31/2018 0.0% 100%TEM Grav. Reduction None DetectedYellow
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0021013DD052818
Front of Bldg - Exterior Expansion Joint Caulk
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 6% 94%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0022014DD052818
Side of Bldg - Exterior Expansion Joint Caulk
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 8% 92%PLM White None Detected
5/31/2018 1.8% 95.4% AnthophylliteTEM Grav. Reduction White 2.8%
Test Report:EPAMultiTests-7.32.2.D Printed: 5/31/2018 03:38PM Page 3 of 5
EMSL Analytical, Inc.
1056 Stelton Road Piscataway, NJ 08854
Phone/Fax: (732) 981-0550 / (732) 981-0551http://www.EMSL.com / [email protected]
ENVI65051802212EMSL Order ID:
Customer ID:
Customer PO:
Project ID:
Summary Test Report for Asbestos Analysis in Accordance with N.J.A.C. 8:60 and 12:120
via EPA 600/R-93/116
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0023015DD052818
Office #3 - Caulk Assoc. w/ Window Panel
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 8% 92%PLM White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0024016DD052818
Office #2 - Caulk Assoc. w/ Window Panel
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 8% 92%PLM White None Detected
5/31/2018 0.91% 97.6% AnthophylliteTEM Grav. Reduction White 1.5%
Chrysotile<0.30%
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0025017DD052818
Storage/Parts - Fire Caulk
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 <1% 100%PLM Red None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0026018DD052818
Storage/Parts - Fire Caulk
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 <1% 100%PLM Red None Detected
5/31/2018 0.0% 100%TEM Grav. Reduction None DetectedRed
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0027019DD052818
Bay - Sheet Rock Ceiliing Panels
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 15% 85%PLM Brown/Tan None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0028020DD052818
Storage/Parts Rm - Sheet Rock Ceiling Panels
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 18% 82%PLM Brown/Tan None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0029021DD052818
Men's Rm - Plaster Wall
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 0% 100%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0030022DD052818
Men's Rm - Plaster Wall
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 0% 100%PLM Gray None Detected
Test Report:EPAMultiTests-7.32.2.D Printed: 5/31/2018 03:38PM Page 4 of 5
EMSL Analytical, Inc.
1056 Stelton Road Piscataway, NJ 08854
Phone/Fax: (732) 981-0550 / (732) 981-0551http://www.EMSL.com / [email protected]
ENVI65051802212EMSL Order ID:
Customer ID:
Customer PO:
Project ID:
Summary Test Report for Asbestos Analysis in Accordance with N.J.A.C. 8:60 and 12:120
via EPA 600/R-93/116
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0031023DD052818
Men's Rm - Plaster Wall
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 <1% 100%PLM Gray None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0032024DD052818
Ext. @ Door - Ext. Window Cashing Caulk
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 5% 95%PLM Gray/White None Detected
Client Sample ID:
Sample Description:
Lab Sample ID: 051802212-0033025DD052818
Ext. @ Double Door - Ext. Window Cashing Caulk
DateTEST Non-Fibrous Asbestos CommentColor Fibrous
Non-AsbestosAnalyzed
5/30/2018 3% 97%PLM Gray/White None Detected
5/31/2018 0.11% 99.8% AnthophylliteTEM Grav. Reduction Gray/White 0.11%
Analyst(s):
PLM (6)
TEM Grav. Reduction (11)
David Moody
PLM (27)Susan Pollack
Chaiyut Sae Lao, Laboratory Manager
or Other Approved Signatory
Reviewed and approved by:
EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may not be reproduced,
except in full, without written approval by EMSL. This test report must not be used to claim product endorsement by NVLAP or any agency of
the U.S. Government. EMSL bears no responsibility for sample collection activities or analytical method limitations. The laboratory is not
responsible for the accuracy of results when requested to physically separate and analyze layered samples. PLM alone is not consistently
reliable in detecting asbestos in floor coverings and similar NOBs.
Samples analyzed by EMSL Analytical, Inc. Piscataway, NJ NYS ELAP 11423, NVLAP Lab Code 101048-2, NJ NELAC 12037, Philadelphia
289, CT PH-0266Initial report from: 05/30/201813:18:22
Test Report:EPAMultiTests-7.32.2.D Printed: 5/31/2018 03:38PM Page 5 of 5
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 5 Penn Plaza, Suite 1972 ● New York, New York 10001 ● tel: 212-952-7300
APPENDIX II
PHOTOGRAPHS
Site Photographs
Date Taken May 29, 2018
Client New Jersey Department of Transportation
Location Jersey City Maintenance Yard
EC Project # 18163-01 Address 401 Lincoln Highway, Jersey City, NJ 07306
Photograph 1 – Asbestos Containing Exterior Window Panel Caulk
Photograph 2 - Asbestos Containing Expansion Joint Caulk
Site Photographs
Date Taken May 29, 2018
Client New Jersey Department of Transportation
Location Jersey City Maintenance Yard
EC Project # 18163-01 Address 401 Lincoln Highway, Jersey City, NJ 07306
Photograph 3 – Lead Based Paint on Metal Bollards @ Garage Bay
Photograph 4 – Lead Based Paint on Metal Pipe In Garage Bay
Site Photographs
Date Taken May 29, 2018
Client New Jersey Department of Transportation
Location Jersey City Maintenance Yard
EC Project # 18163-01 Address 401 Lincoln Highway, Jersey City, NJ 07306
Photograph 5 – Lead Based Paint on Metal Columns @ Garage Bay
Photograph 6 – Lead Based Paint on Recessed Metal Columns and Beams
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 5 Penn Plaza, Suite 1972 ● New York, New York 10001 ● tel: 212-952-7300
APPENDIX III
LEAD BASED PAINT INSPECTION DATA
Date: May 28, 2018 Page: 1 of 4
Client: NJ DOT Unit #: 1
Building: Jersey City Maintainence Yard Job#: 05-28-2018-1215
Address: Rt. 1 & 9 XRF Serial #: 1390
Jersey City, NJ EC#: 18163-01
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 ● fax: 609-392-1216
5 Penn Plaza, Suite 1972 ● New York, NY 10001 ● tel: 212-952-7300
XRF LEAD BASED PAINT INSPECTION DATA SHEET
Sample #
Test Location/Room Equivalent
Substrate
Component
XRF
Value
Classification
(pos., neg., inc.)
Condition/
Comments
1 Calibration - - 1.0 - -
2 Calibration - - 1.0 - -
3 Calibration - - 1.0 - -
4 Building 1336 Wall A Sheetrock Wall -0.1 Neg.
5 Building 1336 Wall A Metal Window Sill -0.0 Neg.
6 Building 1336 Wall A Metal Wall -0.3 Neg.
7 Building 1336 Wall A Metal Door -0.1 Neg.
8 Building 1336 Wall A Metal Door Frame -0.2 Neg.
9 Building 1336 Wall B Sheetrock Wall -0.2 Neg.
10 Building 1336 Center Office Wall B Wood Window Sill -0.1 Neg.
11 Building 1336 Center Office Wall B Metal Wall -0.1 Neg.
12 Building 1336 Center Office Wall C Metal Door -0.1 Neg.
13 Building 1336 Center Office Wall C Metal Door Frame -0.2 Neg.
Lead Inspector/Risk Assessor: Dominick Dercole
Substrate: SR = Sheetrock C = concrete B = Brick W = Wood PL = Plaster CB = Cinderblock M = Metal
Component: W = Wall F = Floor C = Ceiling Wd = Window WF = Window Frame WC = Window Casing WM = Window Mullion WS = Window Sill WSH = Window Sash
D = Door DF = Door Frame DC = Door Casing DJ = Door Jamb H = Header CB = Covebase T = Trim CR = Chair Rail S = Stairs Ri = Riser Ru = Runner SM Stair Mullion
Date: May 28, 2018 Page: 2 of 4
Client: NJ DOT Unit #: 1
Building: Jersey City Maintainence Yard Job#: 05-28-2018-1215
Address: Rt. 1 & 9 XRF Serial #: 1390
Jersey City, NJ EC#: 18163-01
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 ● fax: 609-392-1216
5 Penn Plaza, Suite 1972 ● New York, NY 10001 ● tel: 212-952-7300
XRF LEAD BASED PAINT INSPECTION DATA SHEET
Sample #
Test Location/Room Equivalent
Substrate
Component
XRF
Value
Classification
(pos., neg., inc.)
Condition/
Comments
14 Building 1336 Break Room Wall A Sheetrock Wall -0.2 Neg.
15 Building 1336 Break Room Wall A Wood Window Sill -0.1 Neg.
16 Building 1336 Break Room Wall C Sheetrock Wall -0.2 Neg.
17 Building 1336 Exterior Wall A Metal Wall -0.6 Neg.
18 Building 1336 Exterior Wall B Metal Wall -0.2 Neg.
19 Exterior Garage Bay Wall A Metal Door Trim -0.3 Neg.
20 Exterior Garage Bay Wall A Metal Bollard 1.0 Inc. Paint Chip (+)
21 Interior Garage Bay Wall A Cinderblock Wall -0.5 Neg.
22 Interior Garage Bay Wall D Metal Column 3.5 Pos.
23 Interior Garage Bay Wall D Metal Pipe 2.2 Pos.
24 Interior Garage Bay Wall B Cinderblock Wall -0.6 Neg.
25 Interior Garage Bay Wall C Cinderblock Wall -0.5 Neg.
26 Interior Garage Bay Wall C Metal Door Trim 0.1 Neg.
Lead Inspector/Risk Assessor: Dominick Dercole
Substrate: SR = Sheetrock C = concrete B = Brick W = Wood PL = Plaster CB = Cinderblock M = Metal
Component: W = Wall F = Floor C = Ceiling Wd = Window WF = Window Frame WC = Window Casing WM = Window Mullion WS = Window Sill WSH = Window Sash
D = Door DF = Door Frame DC = Door Casing DJ = Door Jamb H = Header CB = Covebase T = Trim CR = Chair Rail S = Stairs Ri = Riser Ru = Runner SM Stair Mullion
Date: May 28, 2018 Page: 3 of 4
Client: NJ DOT Unit #: 1
Building: Jersey City Maintainence Yard Job#: 05-28-2018-1215
Address: Rt. 1 & 9 XRF Serial #: 1390
Jersey City, NJ EC#: 18163-01
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 ● fax: 609-392-1216
5 Penn Plaza, Suite 1972 ● New York, NY 10001 ● tel: 212-952-7300
XRF LEAD BASED PAINT INSPECTION DATA SHEET
Sample #
Test Location/Room Equivalent
Substrate
Component
XRF
Value
Classification
(pos., neg., inc.)
Condition/
Comments
27 Interior Garage Bay Wall C Metal Bollard -0.2 Neg.
28 Interior Garage Bay Center Metal Column 2.4 Pos. Red
29 Interior Parts Wall A Wood Work Bench -0.1 Neg.
30 Interior Parts Wall A Cinderblock Wall -0.5 Neg.
31 Interior Parts Column Metal Column -0.1 Neg.
32 Interior Parts Column Metal Column 2.1 Pos. Brown
33 Interior Parts Wall D Metal Recessed
Column 2.9
Pos. Brown
34 Interior Parts Wall D Metal Recessed Beam 1.4 Pos. Brown
35 Interior Large Bay Wall C Brick Wall -0.3 Neg.
36 Interior Parts Wall C Brick Wall -0.4 Neg.
37 Interior Parts Wall A Cinderblock Wall -0.4 Neg.
38 Exterior Domar Metal Trim Metal Door Trim -0.3 Neg.
39 Exterior Domar Metal Bollard -0.2 Neg.
Lead Inspector/Risk Assessor: Dominick Dercole
Substrate: SR = Sheetrock C = concrete B = Brick W = Wood PL = Plaster CB = Cinderblock M = Metal
Component: W = Wall F = Floor C = Ceiling Wd = Window WF = Window Frame WC = Window Casing WM = Window Mullion WS = Window Sill WSH = Window Sash
D = Door DF = Door Frame DC = Door Casing DJ = Door Jamb H = Header CB = Covebase T = Trim CR = Chair Rail S = Stairs Ri = Riser Ru = Runner SM Stair Mullion
Date: May 28, 2018 Page: 4 of 4
Client: NJ DOT Unit #: 1
Building: Jersey City Maintainence Yard Job#: 05-28-2018-1215
Address: Rt. 1 & 9 XRF Serial #: 1390
Jersey City, NJ EC#: 18163-01
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 ● fax: 609-392-1216
5 Penn Plaza, Suite 1972 ● New York, NY 10001 ● tel: 212-952-7300
XRF LEAD BASED PAINT INSPECTION DATA SHEET
Sample #
Test Location/Room Equivalent
Substrate
Component
XRF
Value
Classification
(pos., neg., inc.)
Condition/
Comments
40 Exterior @ Calcium Tanks Metal Bollard -0.2 Neg.
41 Exterior @ Front Calcium Tank Metal Bollard -0.3 Neg.
42 Exterior Gas Pumps Metal Bollard -0.2 Neg.
43 Exterior Gas Pumps Metal Pump Foundation -0.0 Neg.
44 Building 1336 Panels Under Windows Metal Panels -0.0 Neg.
45 Calibration - - 1.0 - -
46 Calibration - - 1.0 - -
47 Calibration - - 1.0 - -
Lead Inspector/Risk Assessor: Dominick Dercole
Substrate: SR = Sheetrock C = concrete B = Brick W = Wood PL = Plaster CB = Cinderblock M = Metal
Component: W = Wall F = Floor C = Ceiling Wd = Window WF = Window Frame WC = Window Casing WM = Window Mullion WS = Window Sill WSH = Window Sash
D = Door DF = Door Frame DC = Door Casing DJ = Door Jamb H = Header CB = Covebase T = Trim CR = Chair Rail S = Stairs Ri = Riser Ru = Runner SM Stair Mullion
Client Sample Description ConcentrationLab ID Analyzed WeightLead
Collected
EMSL Analytical, Inc.200 Route 130 North, Cinnaminson, NJ 08077
Phone/Fax: (856) 303-2500 / (856) 786-5974
http://www.EMSL.com [email protected]
Attn: Linda Kelly
Environmental Connection, Inc.
120 North Warren Street
Trenton, NJ 08608
Received: 05/30/18 9:00 AM
NJDOT - Jersey City Maintenance Yard / Project No. 18163-01 / Building 1336
Fax:
Phone: (609) 392-4200
Project:
5/29/2018Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
201805783
CustomerID: ENVI65
CustomerPO:
ProjectID: NJ DOT
EMSL Order:
0.2685
Site: Bay Area Bollard
201805783-0001PC01LK052918 1.2 % wt5/30/2018 g5/29/2018
Page 1 of 1
Phillip Worby, Lead Laboratory Manageror other approved signatory
Test Report ChmSnglePrm/nQC-7.32.3 Printed: 5/31/2018 9:54:40 AM
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008 % wt based on the minimum sample weight per our SOP. Unless noted, results in
this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for
sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NELAP Certifications: NJ 03036, NY 10872, PA 68-00367, AIHA-LAP, LLC ELLAP 100194, A2LA 2845.01
Initial report from 05/31/2018 09:54:40
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 5 Penn Plaza, Suite 1972 ● New York, New York 10001 ● tel: 212-952-7300
APPENDIX IV
POLYCHLORINATED BIPHENYL ANALYTICAL REPORTS AND CHAIN OF CUSTODY
Phillip Worby, Environmental Chemistry Laboratory Director
Approved By:
Fax:
Phone: (609) 392-4200
The following analytical report covers the analysis performed on samples submitted to EMSL Analytical, Inc. on 5/30/2018. The results are tabulated on the attached data pages for the following client designated project:
18163-01 Jersey City Maintenance Yard
The reference number for these samples is EMSL Order #011804155. Please use this reference when calling about these samples. If you have any questions, please do not hesitate to contact me at (856) 303-2500.
6/7/2018Attn: Dom Dercole
Environmental Connection, Inc.
120 North Warren Street
Trenton, NJ 08608
The test results contained within this report meet the requirements of NELAP and/or
the specific certification program that is applicable, unless otherwise noted.
NELAP Certifications: NJ 03036, NY 10872, PA 68-00367, CA ELAP 1877
The samples associated with this report were received in good condition unless otherwise noted. This report relates only to those items tested as received by the laboratory. The QC data associated with the sample results meet the recovery and precision requirements established by the NELAP, unless specifically indicated. All results for soil samples are reported on a dry weight basis, unless otherwise noted. This report may not be reproduced except in full and without written approval by EMSL Analytical, Inc.
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077
Phone: (856) 303-2500 Fax: (856) 858-4571 Email: [email protected]
Page 1 of 4
EMSL Analytical, Inc.200 Route 130 North, Cinnaminson, NJ 08077
Phone/Fax: (856) 303-2500 / (856) 858-4571
http://www.EMSL.com [email protected]
011804155
CustomerID: ENVI65
CustomerPO:
ProjectID:
EMSL Order:
Analytical Results
Attn: Dom Dercole
Environmental Connection, Inc.
120 North Warren Street
Trenton, NJ 08608
Received: 05/30/18 9:00 AM
18163-01 Jersey City Maintenance Yard
Fax:
Phone: (609) 392-4200
Project:
Client Sample Description Lab ID:PCB01-DD052918 011804155-0001Exterior Window - Glazing
Collected: 5/28/2018
Method Parameter Result UnitsAnalysis Date AnalystRL
Prep Date Analyst
GC-SVOA
3540C/8082A Aroclor-1016 EHND mg/Kg 6/5/20180.89 6/4/2018 SDD
3540C/8082A Aroclor-1221 EHND mg/Kg 6/5/20180.89 6/4/2018 SDD
3540C/8082A Aroclor-1232 EHND mg/Kg 6/5/20180.89 6/4/2018 SDD
3540C/8082A Aroclor-1242 EHND mg/Kg 6/5/20180.89 6/4/2018 SDD
3540C/8082A Aroclor-1248 EHND mg/Kg 6/5/20180.89 6/4/2018 SDD
3540C/8082A Aroclor-1254 EHND mg/Kg 6/5/20180.89 6/4/2018 SDD
3540C/8082A Aroclor-1260 EHND mg/Kg 6/5/20180.89 6/4/2018 SDD
3540C/8082A Aroclor-1262 EHND mg/Kg 6/5/20180.89 6/4/2018 SDD
3540C/8082A Aroclor-1268 EHND mg/Kg 6/5/20180.89 6/4/2018 SDD
Client Sample Description Lab ID:PCB02-DD052918 011804155-0002Exterior Window - Panel Caulk
Collected: 5/28/2018
Method Parameter Result UnitsAnalysis Date AnalystRL
Prep Date Analyst
GC-SVOA
3540C/8082A Aroclor-1016 EHND mg/Kg 6/5/20180.87 6/4/2018 SDD
3540C/8082A Aroclor-1221 EHND mg/Kg 6/5/20180.87 6/4/2018 SDD
3540C/8082A Aroclor-1232 EHND mg/Kg 6/5/20180.87 6/4/2018 SDD
3540C/8082A Aroclor-1242 EHND mg/Kg 6/5/20180.87 6/4/2018 SDD
3540C/8082A Aroclor-1248 EHND mg/Kg 6/5/20180.87 6/4/2018 SDD
3540C/8082A Aroclor-1254 EHND mg/Kg 6/5/20180.87 6/4/2018 SDD
3540C/8082A Aroclor-1260 EHND mg/Kg 6/5/20180.87 6/4/2018 SDD
3540C/8082A Aroclor-1262 EHND mg/Kg 6/5/20180.87 6/4/2018 SDD
3540C/8082A Aroclor-1268 EHND mg/Kg 6/5/20180.87 6/4/2018 SDD
Client Sample Description Lab ID:PCB03-DD052918 011804155-0003Expansion Joint - Caulk
Collected: 5/28/2018
Method Parameter Result UnitsAnalysis Date AnalystRL
Prep Date Analyst
GC-SVOA
3540C/8082A Aroclor-1016 EHND mg/Kg 6/7/20180.98 6/6/2018 ABD
3540C/8082A Aroclor-1221 EHND mg/Kg 6/7/20180.98 6/6/2018 ABD
3540C/8082A Aroclor-1232 EHND mg/Kg 6/7/20180.98 6/6/2018 ABD
3540C/8082A Aroclor-1242 EHND mg/Kg 6/7/20180.98 6/6/2018 ABD
3540C/8082A Aroclor-1248 EHND mg/Kg 6/7/20180.98 6/6/2018 ABD
Page 2 of 4ChemSmplw/RDL/NELAC-7.52.0 Printed: 6/7/2018 5:06:31 PM
EMSL Analytical, Inc.200 Route 130 North, Cinnaminson, NJ 08077
Phone/Fax: (856) 303-2500 / (856) 858-4571
http://www.EMSL.com [email protected]
011804155
CustomerID: ENVI65
CustomerPO:
ProjectID:
EMSL Order:
Analytical Results
Attn: Dom Dercole
Environmental Connection, Inc.
120 North Warren Street
Trenton, NJ 08608
Received: 05/30/18 9:00 AM
18163-01 Jersey City Maintenance Yard
Fax:
Phone: (609) 392-4200
Project:
Client Sample Description Lab ID:PCB03-DD052918 011804155-0003Expansion Joint - Caulk
Collected: 5/28/2018
Method Parameter Result UnitsAnalysis Date AnalystRL
Prep Date Analyst
GC-SVOA
3540C/8082A Aroclor-1254 EHND mg/Kg 6/7/20180.98 6/6/2018 ABD
3540C/8082A Aroclor-1260 EHND mg/Kg 6/7/20180.98 6/6/2018 ABD
3540C/8082A Aroclor-1262 EHND mg/Kg 6/7/20180.98 6/6/2018 ABD
3540C/8082A Aroclor-1268 EHND mg/Kg 6/7/20180.98 6/6/2018 ABD
Client Sample Description Lab ID:PCB04-DD052918 011804155-0004Caulk on Door
Collected: 5/28/2018
Method Parameter Result UnitsAnalysis Date AnalystRL
Prep Date Analyst
GC-SVOA
3540C/8082A Aroclor-1016 EHND mg/Kg 6/5/20181.0 6/4/2018 SDD
3540C/8082A Aroclor-1221 EHND mg/Kg 6/5/20181.0 6/4/2018 SDD
3540C/8082A Aroclor-1232 EHND mg/Kg 6/5/20181.0 6/4/2018 SDD
3540C/8082A Aroclor-1242 EHND mg/Kg 6/5/20181.0 6/4/2018 SDD
3540C/8082A Aroclor-1248 EHND mg/Kg 6/5/20181.0 6/4/2018 SDD
3540C/8082A Aroclor-1254 EHND mg/Kg 6/5/20181.0 6/4/2018 SDD
3540C/8082A Aroclor-1260 EHND mg/Kg 6/5/20181.0 6/4/2018 SDD
3540C/8082A Aroclor-1262 EHND mg/Kg 6/5/20181.0 6/4/2018 SDD
3540C/8082A Aroclor-1268 EHND mg/Kg 6/5/20181.0 6/4/2018 SDD
Client Sample Description Lab ID:PCB05-DD052918 011804155-0005Exterior Window Cashing Caulk
Collected: 5/28/2018
Method Parameter Result UnitsAnalysis Date AnalystRL
Prep Date Analyst
GC-SVOA
3540C/8082A Aroclor-1016 EHND mg/Kg 6/5/20180.97 6/4/2018 SDD
3540C/8082A Aroclor-1221 EHND mg/Kg 6/5/20180.97 6/4/2018 SDD
3540C/8082A Aroclor-1232 EHND mg/Kg 6/5/20180.97 6/4/2018 SDD
3540C/8082A Aroclor-1242 EHND mg/Kg 6/5/20180.97 6/4/2018 SDD
3540C/8082A Aroclor-1248 EHND mg/Kg 6/5/20180.97 6/4/2018 SDD
3540C/8082A Aroclor-1254 EHND mg/Kg 6/5/20180.97 6/4/2018 SDD
3540C/8082A Aroclor-1260 EHND mg/Kg 6/5/20180.97 6/4/2018 SDD
3540C/8082A Aroclor-1262 EHND mg/Kg 6/5/20180.97 6/4/2018 SDD
3540C/8082A Aroclor-1268 EHND mg/Kg 6/5/20180.97 6/4/2018 SDD
Page 3 of 4ChemSmplw/RDL/NELAC-7.52.0 Printed: 6/7/2018 5:06:31 PM
EMSL Analytical, Inc.200 Route 130 North, Cinnaminson, NJ 08077
Phone/Fax: (856) 303-2500 / (856) 858-4571
http://www.EMSL.com [email protected]
011804155
CustomerID: ENVI65
CustomerPO:
ProjectID:
EMSL Order:
ND - indicates that the analyte was not detected at the reporting limitRL - Reporting Limit (Analytical)D - Dilution
Definitions:
Page 4 of 4ChemSmplw/RDL/NELAC-7.52.0 Printed: 6/7/2018 5:06:31 PM
120 North Warren Street ● Trenton, New Jersey 08608 ● tel: 609-392-4200 5 Penn Plaza, Suite 1972 ● New York, New York 10001 ● tel: 212-952-7300
APPENDIX V
CERTIFICATIONS/ACCREDITATIONS
AIHA Laboratory Accreditation Programs, LLC
acknowledges that
EMSL Analytical, Inc. 200 Route 130 North, Cinnaminson, NJ 08077
Laboratory ID: 100194 along with all premises from which key activities are performed, as listed above, has fulfilled the requirements of the AIHA Laboratory Accreditation Programs (AIHA-LAP), LLC accreditation to the ISO/IEC 17025:2005 international standard, General Requirements for the Competence of Testing and Calibration Laboratories in the following:
LABORATORY ACCREDITATION PROGRAMS
INDUSTRIAL HYGIENE Accreditation Expires: September 01, 2018 ENVIRONMENTAL LEAD Accreditation Expires: September 01, 2018 ENVIRONMENTAL MICROBIOLOGY Accreditation Expires: September 01, 2018 FOOD Accreditation Expires: UNIQUE SCOPES Accreditation Expires: Specific Field(s) of Testing (FoT)/Method(s) within each Accreditation Program for which the above named laboratory maintains accreditation is outlined on the attached Scope of Accreditation. Continued accreditation is contingent upon successful on-going compliance with ISO/IEC 17025:2005 and AIHA-LAP, LLC requirements. This certificate is not valid without the attached Scope of Accreditation. Please review the AIHA-LAP, LLC website (www.aihaaccreditedlabs.org) for the most current Scope.
William Walsh, CIH Chairperson, Analytical Accreditation Board