renna led type: project
TRANSCRIPT
SPECIFICATIONS Type:
Project:
1© 2014-2021 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products and technologies in this document may be covered by one or more U.S. Patents and Patents Pending. NOTE: Specifications subject to change without notice.
PeerlessLighting.com1-800-705-SERV (7378) | [email protected]
Rev. 06/24/21
Renna LEDRNNAID | LED | Indirect/Direct | Suspended
empowered
RNNAS (Surface Mount)RNNAVWW (Vertical Wall Wash)
RNNAD (Direct Only)
DIMENSIONS
STANDARD DISTRIBUTION
60% Up | 40% Down
DETAILS
COMPANION LUMINAIRE(S)
CUSTOMIZATION
Ask us about the following possibilities: Transitions, additional distributions, additional mounting options, custom colors, and other modifications.
n RNNAID
HIGHLIGHTS
• Total System Integration features 5-year limited warranty by Acuity Brands covering all components and construction
• 4' and 8' sections. Eight base direct and indirect distributions available
• Up to 134 lm/W
• High performance batwing distribution using injection molded optic.
• Optional dual circuit switching for independent dimming of indirect and direct light outputs.
• Softshine® engineered comfort optics
• Flicker free dimming to dark (0.1%) powered by Modulus power and control architecture with integrated digital nLight® module for system networking
• Standard square end plates, rounded or sculpted end plates optional
• White, black, painted aluminum or custom color
LUMEN PACKAGES Based on 3500K. Additional color temperatures available.
Indirect LED Output / Direct LED Output
I300LMF / 300LMF
I600 LMF / 500LMF
I900LMF / 700LMF
I1200LMF / 900LMF
Indirect Delivered Lumens Per Foot / Direct Delivered Lumens Per Foot
300 / 300 600 / 500 900 / 700 1200 / 900
Total Delivered Lumens Per Foot 600 1100 1600 2100
Input Watts Per Foot 5.6 9.5 13.9 17.7
Direct Lumens Per Watt 93 98 99 102
Indirect Lumens Per Watt 125 132 134 131
1 5⁄16"
4 3⁄16"
C
C
1516"
4316"
RNNAID
REVISIONS
ZONE REV. DESCRIPTION ECO DATE DRAWNBY CHKR
DRAWING NO.
REQUIRED
REQUIRED
REQUIREDSHEET 2 OF 3
1/9/1900REQUIRED
UNLESS OTHERWISE SPECIFIED:
WEIGHT
REV
PART NO.
DESCRIPTION
NAME DATE
CHK BY:
DWN BY:
ENG BY:
DRAWING PREPARED IN ACCORDANCE WITH ANSI Y14.5M-1982
DIMENSIONS ARE IN INCHES TOLERANCES:
ANGULAR: 2XX: .03
XXX: .015
PROPRIETARY AND CONFIDENTIAL
THIS PRINT IS THE CONFIDENTIAL PROPERTY OF
ACUITY BRANDS AND IS LOANED SUBJECT TO RETURN UPON DEMAND AND UPON EXPRESS CONDITION THAT IT WILL NOT BE DISCLOSED TO
ANY THIRD PARTY WITHOUT THE PRIOR WRITTEN PERMISSION OF
ACUITY BRANDS OR USED DIRECTLY OR INDIRECTLY IN
ANY WAY DETRIMENTAL TO THE INTEREST OF ACUITY BRANDS
THIRD ANGLE PROJECTION
DO NOT SCALE DRAWING
REQUIREDFINISH
MATERIAL
BSIZE
SCALE: 1:8
A A
B B
4
4
3
3
2
2
1
1
SQEP (Square End Plate) REP (Round End Plate) SCEP (Sculpted End Plate)
SM
© 2014-2021 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products and technologies in this document may be covered by one or more U.S. Patents and Patents Pending. NOTE: Specifications subject to change without notice.
PeerlessLighting.com1-800-705-SERV (7378) | [email protected]
Rev. 06/24/21
Type:
Project:
2
Renna LEDRNNAID | LED | Indirect/Direct | Suspended
MODEL NUMBER Example: RNNAID LLP 32FT MSL8 90CRI 35K I600LMF 500LMF SSH DARK 277 DCT F1/48A C210 REP
t t t t t t t t
Luminaire Linear Length Plan Total Run Length Maximum Section Length LED Color Rendering LED Color Temperature Indirect LED Ouput Direct LED Output
RNNAID LLP Linear longest possible
LSL Longest same length
LCB Longest Center Balanced
__FT Indicate Luminaire Row Length in 2’ increments. Ex: 26FT*2’ only available in a run not as an individual fixture. Ex 6FT MSL4
MSL4 4' Section(s)MSL8 8' Section(s)
90CRI 90+ CRI 27K 2700K30K 3000K35K 3500K40K 4000K50K 5000K
I300LMF 300 Nominal lumens per foot
I600LMF 600 Nominal lumens per foot
I900LMF 900 Nominal lumens per foot
I1200LMF 1200 Nominal lumens per foot
*Available in 100 lumen increments between min & max LMF
300LMF 300 Nominal lumens per foot
500LMF 500 Nominal lumens per foot
700LMF 700 Nominal lumens per foot
900LMF 900 Nominal lumens per foot
*Available in 100 lumen increments between min & max LMF
t t t t t
Direct Lens (Light Guide Plate) Minimum Dimming Level Control Input Voltage Wiring Option Emergency OptionsSSH SoftShine DARK Constant current,
dimming to < 1%MIN1 Constant Current
dimming to 1%
ZT* 0-10VNLIGHT** nLight enabledDALI*** DALI enabledNLTAIR2 nLight AIR enabledECOI Lutron Ecosystem
Interface*0-10V will use linear dimming curve** Will use logarithmic dimming curve***Not available with sensors***Will use logarithmic dimming curve
120 120V277 277V347* 347VMVOLT 120V-277V*347V not available with ECOI, EC, E35INV or WEC
SCT Single circuitDCT* Dual circuit*Not available with NLTAIR2
(Blank) None_EC Emergency circuit moduleE35INV * 35W Emergency Micro InverterWEC Whole run on EC circuit*Not available with 27K, 50K, 347V, MVOLT or CPOnly available on runs of 8ft or greater
t
Primary Sensor or Zone Secondary Zone Tertiary Zone(blank) Select if single zoneNS_* Select if multi-zones required (with no
sensors), call out length of zone in feet. Zone length must match whole fixture lengths, zones cannot end mid-fixture.
_VTX15FADC** Vertex Sensor
*Not available with NLTAIR2** Only available with NLIGHT. Max 5 Vertex sensor per run. Not available with secondary or tertiary zones
(blank) Select if single zoneSNS_ Select if secondary zone is required (with no
sensors), call out length of zone in feet. Zone length must match whole fixture lengths, zones cannot end mid-fixture.*Not available with NLTAIR2
(blank) Select if single zoneTNS_ Select if tertiary zone is required (with no
sensors), call out length of zone in feet. Zone length must match whole fixture lengths, zones cannot end mid-fixture.*Not available with NLTAIR2
t t
Mounting Type/ Overall Suspension Color End Caps OptionsF1/* T-bar ceiling (universal
mounting bracket)F1A/* T-bar ceiling (universal
mounting bracket) with integrated J-box)
F2/** Hard ceiling (horizontal J-box)
*F1 & F1A Mount uses standard 3 1/2” canopy on feed and 2” canopy on support
**F2 Mount uses standard 5” canopy on feed and 2” canopy on support
***All feed cords, cord managers and canopies are standard white. They are not painted to match fixture color.
24A 24" adjustable48A 48" adjustable96A 96" adjustable144A 144" adjustableMeasured from ceiling to bottom of luminaire.
C210 Textured WhiteC202 Textured BlackC110 Painted AluminumC099 Custom colorRALTBD* RAL Paint Finishes*RALTBD for pricing only, replace with applicable RAL call out when ready to order. See the RAL BROCHURE for available options
SQEP Square End CapsREP Rounded End CapsSCEP Sculpted End Caps
BLK Black cord, cord manager and canopy
CP Chicago PlenumMCS Matching Canopy at
support for aestheticsOJB Offset J-box at feedSLP* Sloped Ceiling*When SLP is chosen need to choose F2 mount and OJB
A+ Capable options indicated by this color background.
© 2014-2021 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products and technologies in this document may be covered by one or more U.S. Patents and Patents Pending. NOTE: Specifications subject to change without notice.
PeerlessLighting.com1-800-705-SERV (7378) | [email protected]
Rev. 06/24/21
Type:
Project:
3
Renna LEDRNNAID | LED | Indirect/Direct | Suspended
SPECIFICATIONS
HousingExtruded outer and inner aluminum housing for light weight rigidity and support.
End PlatesDie-cast aluminum end plates are mechanically attached with no exposed fasteners. Square end plates standard. Sculpted or Rounded end plates are optional.
ColorStandard colors are textured white, textured black, and painted aluminum. Consult factory for customer colors and RAL color options.
Luminaire Length2’, 4’, and 8’ lengths in a single section for nominal suspension spacing of 4’ and 8’. For total length, add 2 1/2” for each standard end cap, and 4” for each optional end caps.
Source8 standard lumen packages available with 2700K, 3000K, 3500K, 4000K, 5000K CCT all within a 2.5 step MacAdam Ellipse.
OpticsDirect optical system consists of Softshine high performance acrylic lens and microstructure film. Injection-molded indirect optic for optimized batwing distribution.
Modulus Remote Power and Control SystemRemote power source provides “natural dimming” with smooth, continuous and flicker-free dimming to dark (0.1%). Syncing for controls: 2mA max.
THD: <10%. Insignificant inrush current at 120 and 277VAC. FCC Class A and B tested for EMI and RFI. When NLIGHT or DALI is specified driver will be set for logarithmic dimming curve. If control Input of 0-10V is specified driver will be set for linear dimming curve.
Integrated digital nLight® module enables up to 16 Modulus zones via CAT-5e, when nLight® is selected. The Modulus™ head unit outputs a maximum of 10mA into the nLight® bus. For daylight dimming and/or dual technology detection, see Controls page for external sensor options.
Each modulus head unit utilizes 22 device addresses. Tunable White head units consume 14 device addresses.
ElectricalLED light engine — consisting of modular LED boards and eldoLED® dimming driver — is rated for 60,000 hours (L80) at 25° C ambient temperature. Pre-wired with 18AWG fixture wire. Plug in electrical connectors included in fixtures sections, hard wire connections to be made at canopies and head units.
EnvironmentSuitable for damp location.
ValidationcULus listed.Tested to UL2108 Standards. LM-79 tested. Individual sections meet FCC Part 15 requirements.PackagingRecycled cardboard box and inserts. Biodegradable, protective luminaire bag. Recycled kraft paper tape.
Warranty5-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Note: Actual performance may differ as a result of end-user environment and application.All values are design or typical values, measured under laboratory conditions at 25°C.
A+ Capable LuminaireThis item is an A+ capable luminaire, which has been designed and tested to provide consistent color appearance and out-of-the-box control compatibility with simple commissioning.
• All configurations of this luminaire meet the Acuity Brands’ specification for chromatic consistency
• This luminaire is part of an A+ Certified solution for nLight® control networks when ordered with drivers marked by a shaded background*
• This luminaire is part of an A+ Certified solution for nLight control networks, providing advanced control functionality at the luminaire level, when selection includes driver and control options marked by a shaded background*
To learn more about A+, visit www.acuitybrands.com/aplus.
*See ordering tree for details
The product images shown are for illustration purposes only and may not be an exact representation of the product.
© 2014-2021 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products and technologies in this document may be covered by one or more U.S. Patents and Patents Pending. NOTE: Specifications subject to change without notice.
PeerlessLighting.com1-800-705-SERV (7378) | [email protected]
Rev. 06/24/21
Type:
Project:
4
Renna LEDRNNAID | LED | Indirect/Direct | Suspended
FIXTURE PERFORMANCE DATA
EXPECTED LIFE: L80@60,000 HOURS
CCT SCALING CHART
35K I1200LMF/900LMF
Indirect: 131 lm/w
Direct: 102 lm/w
2100 delivered lumens
CCT CRI MULTIPLIER
27K 90CRI .84
30K 90CRI 1.01
35K 90CRI 1
40K 90CRI 1.01
50K 90CRI .84
HEAD UNIT RUN LENGTH CHART
Dir
ect
Lum
en O
utpu
t
Indirect Lumen Output
Lumens/ft 0 I300 I600 I900 I1200
0 32ft 32ft 32ft 32ft 28ft
300 32ft 32ft 32ft 28ft 24ft
500 32ft 32ft 32ft 24ft 20ft
700 32ft 32ft 24ft 20ft 16ft
900 32ft 24ft 20ft 16ft 16ft
*This table indicates 1 Head Unit required for the identified run length *Lumen values based on 3500K color temperature
© 2014-2021 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products and technologies in this document may be covered by one or more U.S. Patents and Patents Pending. NOTE: Specifications subject to change without notice.
PeerlessLighting.com1-800-705-SERV (7378) | [email protected]
Rev. 06/24/21
Type:
Project:
5
Renna LEDRNNAID | LED | Indirect/Direct | Suspended
✓
✓
✓
✓ ✓
✓
✓
✓
MOST COMMON MOUNTING TYPES AND OPTIONS Options available for this specific luminaire are checked in the boxes below.
Mounting TypeF1/ For use with most T-Bar and screw slot grid ceilings. Designed for on-grid and
off-grid applications.F2/ For use with recessed or surface mount horizontal J-box applications.F1A/ For use with most T-Bar and screw slot grid ceilings. Designed for on-grid and off-grid
applications. Comes complete with vertical J-box with built-in wire way. See also CP.
Mounting OptionsMCS Matching canopy at support for aesthetics.OJB Offset J-box at feed.SLP OJB Sloped ceiling couplers and offset J-box option at feed.
Power Feed
Support
n F1/MCS
Power Feed
Support
n F2/SLP OJB
Power Feed
Support
n F2/
Power Feed
Support
n F2/MCS
Power Feed
Support
n F1A/
Power Feed
Support
n F1A/MCS
Power Feed
Support
n F2/OJB
Power Feed
Support
n F1/
n ✓ Indicates mounting options available with this luminaire.
To see more, see the Hanging Hardware Selection Guide.
© 2014-2021 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products and technologies in this document may be covered by one or more U.S. Patents and Patents Pending. NOTE: Specifications subject to change without notice.
PeerlessLighting.com1-800-705-SERV (7378) | [email protected]
Rev. 06/24/21
Type:
Project:
6
Renna LEDRNNAID | LED | Indirect/Direct | Suspended
LINEAR PLAN:
PEERLESS offers the ability to provide a continuous run plan to suit your requirements by optionally offering three different methods of configuration.
LSL- Linear Same Length:In this configuration, each segment is the same length and is standardized based on the longest length available and is the only option provided. Because it is dependent on one segment length there are mathematical limitations on what overall row lengths can be achieved. Example: 20 FT row would be achieved with 5, 4 FT long segments equaling 20 FT (nominal).
LLP- Linear Longest PossibleIn this configuration, the longest length available is optimized, resulting in the fewest segments and mounting locations. Caution, should be used where balanced appearance is a concern. Example: 20 FT run would have 2 - 8 FT segment and 1, 4 FT segment at the end of the run.
LCB- Linear Center Balanced:This configuration incorporates the longest center segment(s) along with any additional lengths required to fill the run length, added to the run ends. Example: 16 FT run would have 2, 4 FT segments (one at each end) and 1, 8 FT segment in the center.
8 FT 8 FT 4 FTLLP
4FT 4FT 4FT 4FT 4FTLSL
4 FT 8 FT 4FTLCB
WEIGHTS & SUPPORT SPACING
ORDERED LENGTH
INDIVIDUAL FIXTURES
2FT
4FT
8FT
"A" O.C.
2'-0"
4'-0"
8'-0"
"B" SQEP OVERALL
2'-4"
4'-4"
8'-4"
"B" SCEP OVERALL
2'-6"
4'-6"
8'-6"
"B" REP OVERALL
2'-6"
4'-6"
8'-6"
APPROX. WEIGHT
4LB
8LB
16LB
ORDERED LENGTH
RUN LAYOUT
2FT
4FT
8FT
"A-1" O.C.
2'-0"
4'-0"
8'-0"
"B-1" SQEP OVERALL "B-1" SCEP OVERALL "B-1" REP OVERALL "B-2" OVERALL"A-2" O.C.
2'-0"
4'-0"
8'-0"
APPROX. WEIGHT
4LB
8LB
16LB
2'-2"
4'-2"
8'-2"
2'-3"
4'-3"
8'-3"
2'-3"
4'-3"
8'-3"
2'-0"
4'-0"
8'-0"
"B"
"A"
"B-1"
"A-1" "A-2" "A-1"
"B-2" "B-1"
Suspension spacing equals section length. Default location shown.
© 2014-2021 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products and technologies in this document may be covered by one or more U.S. Patents and Patents Pending. NOTE: Specifications subject to change without notice.
PeerlessLighting.com1-800-705-SERV (7378) | [email protected]
Rev. 06/24/21
Type:
Project:
7
Renna LEDRNNAID | LED | Indirect/Direct | Suspended
Sensorview Software(only required for rezoning)CAT-5eClass 1 DC Power
Class 1 AC Input
Renna Head Unitwith NLIGHT or
NLT control
Renna Luminaire withIntegral VERTEX Sensor
Drawing #:
Date:
Scale:
Sheet:
PREP
ARED
FO
R:
DR
AWIN
G T
YPE:
Drawn By:
DWG Ref:
DE
SIG
N &
AP
PLI
CA
TIO
NS
PRO
JEC
T N
AME:
NAM
E
RFA
# X
XXXX
-X
SUBM
ITTA
L FO
R A
PPR
OVA
L
AXXX
DATE
ANSI B
XXX
MLX.3
INTELLIGENT LUMINAIRE CHARTS
CONTROLS
Choose nomenclature from these columns
Dri
ver
Conf
igur
atio
ns
Minimum Dimming Level Control Input Driver Dimming
Range Notes
MIN1 + DALI = eldoLED DCDC DUALdrive 100 to 1% Logarithmic Dimming, DALI controls and power supply supplied by others
MIN1 + ZT = eldoLED DCDC DUALdrive 100 to 1% Linear Dimming, supplied with leads for two independent zones of 0-10V
MIN1 + NLIGHT = eldoLED DCDC DUALdrive 100 to 1% Logarithmic Dimming, nIO EZDCA 16Z in head unit
MIN1 + NLTAIR2 = eldoLED DCDC DUALdrive 100 to 1% Logarithmic Dimming, rIO EZDL in head unit with external antenna
MIN1 + TUWH NLT = eldoLED DCDC DUALdrive 100 to 1% Logarithmic Dimming, nIO EZDCA CCT in head unit
MIN1 + ECOI = eldoLED DCDC DUALdrive 100 to 1% Logarithmic Dimming, Lutron TVI-LMF-2A Ecosystem -> 0-10V converter in head unit
DARK DALI eldoLED DCDC DUALdrive 100 to 0.1% Logarithmic Dimming, DALI controls and power supply supplied by others
DARK ZT eldoLED DCDC DUALdrive 100 to 0.1% Linear Dimming, supplied with leads for two independent zones of 0-10V
DARK NLIGHT eldoLED DCDC DUALdrive 100 to 0.1% Logarithmic Dimming, nIO EZDCA 16Z in head unit
DARK NLTAIR2 eldoLED DCDC DUALdrive 100 to 0.1% Logarithmic Dimming, rIO EZDL in head unit with external antenna
DARK TUWH NLT eldoLED DCDC DUALdrive 100 to 0.1% Logarithmic Dimming, nIO EZDCA CCT in head unit
Remote sensors can be paired with NLIGHT options to control your runs.
External nLight DeviceCAT-5eClass 1 DC Power
Class 1 AC Input
Renna Head Unit
Renna Luminaire
Cont
rol +
Sen
sor
Conf
igur
atio
ns
Control Sensor Sensor Notes
NLIGHT + VTX15FADC = VERTEX 15F EZ ADC VLP Available in endcaps or midpoint of 8ft fixture section. Max 5 sensors per run. Zoning reconfigurable via Sensorview software.
NLT + VTX15FADC = VERTEX 15F EZ ADC VLP Available in endcaps or midpoint of 8ft fixture section. Max 5 sensors per run. Zoning reconfigurable via Sensorview software.
FOR EXTERNAL CONTROLS
FOR INTERNAL CONTROLS
© 2014-2021 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products and technologies in this document may be covered by one or more U.S. Patents and Patents Pending. NOTE: Specifications subject to change without notice.
PeerlessLighting.com1-800-705-SERV (7378) | [email protected]
Rev. 06/24/21
Type:
Project:
8
Renna LEDRNNAID | LED | Indirect/Direct | Suspended
REMOTE HEAD UNITS
F1 CEILING DETAILS
GRID MOUNTING BRACKETSUPPLIED FOR EACH SUPPORT
LOCATION
4"X4" J-BOX BY OTHERS(F1A J-BOX PROVIDEDBY PEERLESS)
INPUT CLASS 1BY OTHERS
50'-0" MAX REMOTE HEAD UNIT DISTANCE
TO STRUCTUREBY OTHERS
REMOTE HEAD UNIT
12 GA WIRE ,TO SUPPLYCLASS 1 DC POWER TOLUMINAIRE BY OTHERS POWER FROM
HEAD UNITTO STRUCTUREBY OTHERS
J-BOX AND MOUNTING MEANSBY OTHERS
50'-0" MAX REMOTE HEAD UNIT DISTANCE
BLOCK/MOUNTING MEANSBY OTHERS
MOUNTING HARDWAREBY OTHERS
12 GA WIRE ,TO SUPPLYCLASS 1 DC POWER TOLUMINAIRE BY OTHERSINPUT CLASS 1
BY OTHERS
POWER FROMHEAD UNIT
F2 CEILING DETAILS
RNNAID...48FTm f
[blank]
m f
[blank]
m f
[blank]
m f
[blank]
m f
FK/L
DK320P
m f
FK/L
1st head unit 2nd head unitf
ACG8FK
RNNAEP RNNAEP
f
ACG8FKACG8SK ACG8SK ACG8SK ACG8SK ACG8SK
DK320P
© 2014-2021 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products and technologies in this document may be covered by one or more U.S. Patents and Patents Pending. NOTE: Specifications subject to change without notice.
PeerlessLighting.com1-800-705-SERV (7378) | [email protected]
Rev. 06/24/21
Type:
Project:
9
Renna LEDRNNAID | LED | Indirect/Direct | Suspended
REMOTE HEAD UNITS
ADJ1'-6 TO 2'-0"
1'-10 716"
MOUNTING LOCATIONS OVERALL DIMENSIONS2'-2 1/4" X 2'-3/4" X 4 3/4"
1'-6"
912"
MOUNTING LOCATIONS OVERALL DIMENSIONS1'-8 1/4" X 1'- 3/8" X 2 5/8"
MOUNTING LOCATIONS
F1 HEAD UNIT DETAILS F2 HEAD UNIT DETAILS
1'-6"
912"
MOUNTING LOCATIONS OVERALL DIMENSIONS1'-8 1/4" X 1'- 3/8" X 2 5/8"
MOUNTING LOCATIONS
ADJ1'-6 TO 2'-0"
1'-10 716"
MOUNTING LOCATIONS OVERALL DIMENSIONS2'-2 1/4" X 2'-3/4" X 4 3/4"OVERALL DIMENSIONS2'-2 ¼" x 2'-¾" x 4 ¾"
OVERALL DIMENSIONS1'-8 ¼" x 1'-3⁄8" x 2 5⁄8"
© 2014-2021 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products and technologies in this document may be covered by one or more U.S. Patents and Patents Pending. NOTE: Specifications subject to change without notice.
PeerlessLighting.com1-800-705-SERV (7378) | [email protected]
Rev. 06/24/21
Type:
Project:
10
Renna LEDRNNAID | LED | Indirect/Direct | Suspended
EMERGENCY OPTIONS
100%0%0%0%0%0%
0%0%0%0%0% 0%
100% 0%0%
0%0%0%0%0%
100%
0%0%
100%0% 100%
FK/L EC/R
FK/L EC/L EC/L
EC / GTD UNIT
EC / GTD UNIT
E35INV UNIT
10% 10% 10% 10% 10% 10%
0%0%0%0%0% 0%FK/L E35INV E35INV E35INV
RNNAID LLP...1EC
RNNAID LLP...4EC
RNNAID LLP...E35INV
TYPICAL BUILDING LAYOUT
J BOX
J BOX
NORMAL POWER
EC POWER
RNNA
RNNA 1EC
RNNA
RNNA HEAD UNIT
RNNA EC UNIT
RNNA HEAD UNIT
RNNAID LLP...IEC
RNNAID LLP...4EC
RNNAID LLP...E35INV
RNNAID
Emergency Options:EC circuits default to the right side 4’ section, of an 8’ fixture (EC/R) and the complete section of a 4’ fixture (EC/L). Single EC circuit defaults to the last 4’ of the run. Dual EC circuits default to the last 4’ of the run and the first 4’ of the run. Additional circuits will be added from the end of the run using the last 4’ of an 8’ fixture or complete 4’ fixtures. If the final fixture is a 2’ fixture, the EC circuit will be placed at the next available 4’ or 8’ fixture section from the end of the run.
EXAMPLES OF TYPICAL EMERGENCY LAYOUTS.
*During Emergency modes the indirect portion of the luminaire will be disabled.
*Emergency power for the Head Unit is not supposed to be daisy chained from another head unit.
© 2014-2021 Acuity Brands Lighting, Inc. All Rights Reserved. “Peerless” is a registered trademark of Acuity Brands Lighting. Products and technologies in this document may be covered by one or more U.S. Patents and Patents Pending. NOTE: Specifications subject to change without notice.
PeerlessLighting.com1-800-705-SERV (7378) | [email protected]
Rev. 06/24/21
Type:
Project:
11
Renna LEDRNNAID | LED | Indirect/Direct | Suspended
EMERGENCY OPTIONS
INTEGRATED SENSOR LAYOUT
24FT MSL8 run with �ve sensors - 5VTX15FADC
8FT MSL8 run with one sensor - VTX15FADCCORRECT:
8FT MSL8 run with three sensors - 3VTX15FADC
16FT MSL4 run with two sensors - 2VTX15FADC
16FT MSL8 run with �ve sensors - 5VTX15FADC
INCORRECT:
NOTES:
12FT MSL4 run with three sensors - 3VTX15FADC
- 5 sensors max per run- Only U8 �xtures can support internal sensors- Sensors are available in end plates- Sensors in end plates require adjacent VTX/WL or VTX/WR �xture sections- Sensors appear as nLight devices and can be re-zoned in the �eld using Sensorview software- Factory zoning isn’t available with sensors since they can be re-zoned in the �eld using Sensorview- Internal sensors are only available with NLIGHT and NLT control types
Doesn’t work because U4 and U2 sections can’t have internal sensors so MSL4 runs can have at most two sensors, one in each end plate
Doesn’t work because there are only four available spots for sensors - midspan of each U8 section and one in each end plate
Doesn’t work because each sensor requires a separate driver for power and communication, and U8 sections most often only have two drivers
16FT MSL8 run with two sensors and two zones - 2VTX15FADC NS8 SNS8Primary zone - 8FT Secondary zone - 8FT
Doesn’t work because sensors cannot be ordered with factory zoning. Drivers and sensors can be re-zoned using Sensorview software.
32FT MSL8 run with six sensors - 6VTX15FADC
Doesn’t work because each head unit can support at most �ve sensors
0%0%0%0%0% 0%
0%0%0%0%0%
100%
0%0%
EMERGENCY OPTIONS:EC circuits default to the right side 4' section, of an 8' fixture (EC/R) and the complete section of a 4' fixture (EC/L).Single EC circuit defaults to the last 4' of the run.Dual EC circuits default to the last 4' of the run and the first 4' of the run.Additional circuits will be added from the end of the run using the last 4' of an 8' fixture or complete 4' fixtures.If the final fixture is a 2' fixture, the EC circuit will be placed at the next available 4' or 8' fixture section from the end of the run.
FK/L
FK/L EC/L/R EC/L
RNNAID
EC UNIT
EC UNIT
E35INV UNIT
10% 10% 10% 10% 10% 10%
FK/L E35INV E35INV E35INV
RNNAID LLP...1EC
RNNAID LLP...4EC
RNNAID LLP...E35INV
EC/L/R
100% 100%
EC/L/R
100% 100%
EC/L/R
100% 100%
EC/L/R
100% 100%
EC/L/R
100% 100%100% 100%
10% 10% 10% 10% 10% 10%
Drawing #:
Date:
Scale:
Sheet:
PREP
ARED
FO
R:
DR
AWIN
G T
YPE:
Drawn By:
DWG Ref:
DE
SIG
N &
AP
PLI
CA
TIO
NS
PRO
JEC
T N
AME:
NAM
E
RFA
# X
XXXX
-X
SUBM
ITTA
L FO
R A
PPR
OVA
L
AXXX
DATE
ANSI B
XXX
MLX.3
RNNAID LLP ...WEC