Photoelectric Sensors for harsh environments

TRANSCRIPT

Page 1: Remote Sensors And Amplifiers

tel

Page 2: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

PRODUCT TRAINING PROGRAM

Page 3: Remote Sensors And Amplifiers

Remote sensors & PA amplifiers

Page 4: Remote Sensors And Amplifiers

Mode Symbol Advantages Disadvantages

Thru BeamLong rangeHigh excess gain

Mounting and Cabling on 2 sides

Diffuse Proximity

Mounting of one unit only

Short sensing distanceObject dependent

Background Suppression

Mounting one unit only,Color independent

Short sensing distance

Retro reflective

Mounting one unit onlyReflector, Dirt, Alignment

Retro reflective Pol.

Fibre OpticInaccessible and small placesHigh temperatures

Short sensing rangeInstallation

telRemote sensors & PA amplifiers

OPERATION MODES:

Page 5: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

Very small, very compact, sensor dimensions

Easy Alignment in thru beam mode

High penetration power

High Light Immunity

Insensitive to shock and vibrations

IP67 sealing

TELCO’S CORE VALUES

Page 6: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

Insensitive to shock and vibrations

Page 7: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

High Light Immunity

Page 8: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

Easy Alignment in thru beam mode

Page 9: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

High penetration power

Page 10: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

IP67 sealing

Page 11: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

REMOTE SENSORS

Page 12: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

How to identify a sensor ?

LR 110 TB38 5

LR = Light Receiver

110 Series

TB = Threaded Brass 38 = Length

5 = 5 m cable

Red = Transmitter

Yellow = Receiver

Page 13: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

Housing Type

Series Housing Type Dimensions

LT/LR 101 AP 25 Ø 10 x 25 mm

TP 25 M12x1 x 25 mm

TB 25 M12x1 x 25 mm

TS 25 M12x1 x 25 mm

SG 9,5 x 11,5 mm

S 22 Ø 12,7 x 22 mm

LT/LR 100/110

AP 38 Ø 10 x 38 mm

TP 38 M12x1 x 38 mm

TB 38 M12x1 x 38 mm

TS 38 M12x1 x 38 mm

TB 58 M12x1 x 58 mm

TS 58 M12x1 x 58 mm

LT/LR 120 TB 45 M18x1 x 45 mm

AP Smooth Plastic

TPThreaded Plastic

TB Threaded Brass

TS Threaded Steel

SGSpace Guard (Rectangular)

S Snap

Page 14: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

Ga/Al/As 880 nm

LT (Transmitter)Emitting Angles50% Intensity

+/- 10 º Series 101

+/- 12 º Series 100 H

+/- 6 º Series 100

+/- 5 º Series 110

+/- 4 º Series 120

LR (Receiver)Opening Angles50% Intensity

+/- 6 º Series 101

+/- 7 º Series 100

+/- 3 º Series 110

+/- 2,5º Series 120

REMOTE SENSORS

Page 15: Remote Sensors And Amplifiers

Parallel displacement LT 101 and LR 101

-0,6

-0,4

-0,2

0

0,2

0,4

0,6

0 2 4 6 8 10

Range [m]

Dis

pla

cem

ent

[m]

telRemote sensors & PA amplifiers

Page 16: Remote Sensors And Amplifiers

Parallel displacement LT 100 and LR 100

-1,5

-1

-0,5

0

0,5

1

1,5

0 2 4 6 8 10 12 14 16 18 20

Range [m]

Dis

pla

cem

ent

[m]

telRemote sensors & PA amplifiers

Page 17: Remote Sensors And Amplifiers

Parallel displacement LT 110 and LR 110

-1,5

-1

-0,5

0

0,5

1

1,5

0 5 10 15 20 25 30 35 40 45

Range [m]

Dis

pla

ce

me

nt

[m]

telRemote sensors & PA amplifiers

Page 18: Remote Sensors And Amplifiers

Parallel displacement LT 120 and LR 120

-2,5-2

-1,5-1

-0,50

0,51

1,52

2,5

0 10 20 30 40 50 60 70 80

Range [m]

Dis

pla

cem

ent

[m]

telRemote sensors & PA amplifiers

Page 19: Remote Sensors And Amplifiers

Angular displacement LR 101

0

25

50

75

100

125

-20 -15 -10 -5 0 5 10 15 20

deg.

Se

ns

itiv

ity

(n

orm

aliz

ed

)

Angular displacement LR 100

0

25

50

75

100

125

-20 -15 -10 -5 0 5 10 15 20

deg.

Sen

siti

vity

(n

orm

aliz

ed)

Angular displacement LR 110

0

25

50

75

100

125

-20 -15 -10 -5 0 5 10 15 20

deg.

Sen

siti

vity

(n

orm

aliz

ed)

Angular displacement LR 120

0

25

50

75

100

125

-20 -15 -10 -5 0 5 10 15 20

deg.

Sen

siti

vity

(n

orm

aliz

ed)

telRemote sensors & PA amplifiers

Page 20: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

Receivers:

Silicon NPN transistor

Immunity to Sunlight @ 20 º

LR 101 50 000 lux

LR 100 80 000 lux

LR 110/120 100 000 lux

REMOTE SENSORS

Page 21: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

Applicable Photoelectric Amplifiers and Ranges

Page 22: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

USEFUL ACCESSORIES

TRE Ø 10 mm A type

TREM M12 – 1 mm hole

TREGM M12 – 1 mm hole with glass front

TRGM Glass front only

TRWM 90 º shutter

TRPG 11 Tubus

Page 23: Remote Sensors And Amplifiers

- Sensing range: Through beam 0-45 mDiffuse 0-3,5 m

- Automatic mode(teach-in):Setup required (push reset/test button).Power level adjusted according the application.Optimal hysteresys and excess gain.Automatically compensation for misalignment and contamination during operation.

- Manual mode:Manual sensitivity adjustment.Test button disable the transmitter.

- Patented feature STF:Up to 3 identical systems without cross-talk

- Hysteresis: Approx. 20 %

telRemote sensors & PA amplifiers

AUTOMATIC PA TYPESPA 01

Page 24: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

PA 01 A

Page 25: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

PA 01 B

Page 26: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

PA 01 C

Page 27: Remote Sensors And Amplifiers

PA AMPLIFIERS

telRemote sensors & PA amplifiers

- Sensing range: Through beam 0-5mDiffuse 0-45 cm

- Low cost:Designed for elevator and door market

- Only 12 or 24Vdc supply voltage

- Only use with LT/LR 101 serie - 1 relay output acc. to UNI8612

2 relays mounted in series

PA 09

Page 28: Remote Sensors And Amplifiers

PA AMPLIFIERSPA 10

telRemote sensors & PA amplifiers

- Sensing range: Through beam 0-60 m Diffuse 0-4 m

- PA10A:Use in conjunction with LT/LR 101 series

- PA10B:Use with LT/LR 100-110-120 series

- Relay or PNP/NPN output - Manual sensitivity adjustment- LO/DO selectable switch- Long/short range selectable switch- Hysteresis: Approx. 40 %

Page 29: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

PA 10 A only applicable with 101 remote sensors series

PA 10 A/B

Page 30: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

PA AMPLIFIERSPA 11 T

- Sensing range: Through beam 0-70 mDiffuse 0-5 m

- PA11:use with LT/LR 100-110-120 series

- Relay/NPN or PNP/NPN output- 0-10sec. on/off time delay- Manual sensitivity adjustment- LO/DO selectable switch- Long/short range selectable switch- Sensor test during operation (LED

indication)- Hysteresis: Approx. 45 %

Page 31: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

PA 11 A T

Page 32: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

PA 11 B T

Page 33: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

- Sensing range: through beam 0-45 mdiffuse 0-3,5 m

- MPA 21:use with 2 sets LT/LR 100-110-120 series

- Multiplexing function prevent optical cross talk

- 2 individual Relay/NPN or PNP/NPN output 0-10sec. on/off time delay

- Manual sensitivity adjustment- LO/DO selectable switch- Long/short range selectable switch- Hysteresis: Approx. 35 %

MPA AMPLIFIERSMPA 21

Page 34: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

Eliminates cross talk between 2 beams

2 relays or both PNP/NPN output

Short / long range Switch

Sensing Level indicator LED

Output LED

Available with on / off time delay

MPA 21

Page 35: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

MPA 21 A

Page 36: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

MPA 21 B

Page 37: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

- Sensing range: through beam 0-35 mdiffuse 0-2 m

- MPA 41/81:use with 4/8 sets LT/LR 100 -110 - 120 series

- Multiplexing function prevent optical cross talk

- 4/8 individual Relay or PNP/NPN output w/wo 0-10sec.

- 1 relay and transistor common output- Manual sensitivity adjustment- LO/DO selectable switch- Long/short range selectable switch for all

channels- Hysteresis: Approx. 35 %

MPA AMPLIFIERSMPA 41 & MPA

81

Page 38: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

MPA 41 A/C

Page 39: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

MPA 41 B/D

Page 40: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

MPA 81 A/C

Page 41: Remote Sensors And Amplifiers

telRemote sensors & PA amplifiers

MPA 81 B/D

Page 42: Remote Sensors And Amplifiers

tel