reliability & repeatability. - brooks instrument/media/brooks... · 2020. 2. 13. · oir: up to...
TRANSCRIPT
Reliability & Repeatability. Variable Area Flow Meters
Rugged. Economical. Easy to use flow measurement technology
When measuring liquid or gas flow at higher pressures and
temperatures not suitable for plastic, you can achieve accurate
flow rates with robust glass tube variable area flow meters
(rotameters) from Brooks Instrument. With a broader range of
flow rates available, glass tube rotameters are suitable for a variety
of liquids and gases.
Plus, the ability to easily see the float and direct flow scales on the
tube accommodate a variety of applications, whether in the lab or
in industrial processes.
Glass Tube Variable Area Flow Meters
NEW
Sho-Rate™ Models 1350, 1355, 1358 Glass Tube Flow Meters
GT1600 Series Glass Tube Flow Meters
MT3750 Series MetalTube Flow Meters
MT3809 Series MetalTube Flow Meters
The industry standard glass tube VA flow meter for decades. Multiple material options available for a wide variety of applications.
Simple, rugged design for long-lasting performance with low and high-flow gas and liquid applications where viewing the process is important.
Reliable, durable, lowflow measurement forlong-lasting performancein harsh environments.
Widest temperature, pressureand flow ranges for measuringfluids in hazardous, remote areas.
• Rugged, single piece frame construction
• Magnifier built into front shield
• Optional needle valves and flowcontrollers mounted to inlet or outlet for precision flow control
• Standard direct read scales on tube for all fluids and fluid conditions
• Standard millimeter scales with flow curves for all fluids and fluid conditions
• 65mm or 150mm scale lengths
• For use in low-flow applications withhigh-pressure orhazardous fluids
• Compact design
• 4–20 mA output
• Good upgrade from glasstube flow meters
• Optional alarms, transmittersand limit switch controllersprovide added levels ofmeasurement and control
• Independent and easilyaccessible diagnostic/service port
• Repeatable flow measurement evenat low process temperatures downto -198°C/-325°F and high processtemperatures up to 420°C/788°F
• Designed for high process pressures1379 bar / 20,000 psig
• Optional local operator interfacewith LCD screen
• Alarm functions meetSIL 2 requirements
• Multiple corrosion-resistantwetted materials and indicatorhousings available
• Meets ASME B31.3 standard
• Analog & Digital I/Os: 4-20 mA,HART® 7, FOUNDATION Fieldbus™
• Fluid Types — clean liquids and gases
• Flow Range — o Air: Up to 15 scfm / 425 slpm o Water: Up to 5 gpm / 19 lpm
• Accuracy — ±3, ±5, ±10% FS
• Max Pressure — 200 psig (13.8 bar)
• Temperature Range — 1–121°C (33- 250°F)
• Fluid Types — clean liquids and gases
• Flow Range — o Air: Up to 150 scfm/270 m3n/h
o Water: Up to 21 gpm/4,800 l/h
• Accuracy — ±2, ±5, ±10% FS Class 2.5 acc VDI/VDE, (Optional ±1% FS, Class 1.6 acc VDI/VDE)
• Max Pressure — 500 psig (34.5 bar)
• Temperature Range — 1–121°C (33-250°F)
• Fluid Types — clean liquids, gasesand steam
• Flow Range —o Air: Up to 110 scfh / 3.1 m3n/ho Water: Up to 26 gpm / 100 l/h
• Accuracy — ±3, ±5% FSo Class 2.5, 4.0 VDI
• Max Pressure —o Standard 1500 psig (100 bar)o Optional 4000 psig (276 bar)
• Temperature Range —-50–204°C (-58-400°F)
• Fluid Types — clean liquids, gasesand steam
• Flow Range —o Air: Up to 750 scfm / 1200 m3n/
hro Water: Up to 440 gpm /100,000
l/h
• Accuracy — ±1, ±2%, ±3%, ±5% FSo Class 1.6, 2.5, 4.0 VDI
• Max Pressure —o Standard 6000 psig (413.7 bar)o Optional 20,000 psig (1379 bar)
• Temperature Range —-198–420°C (-325-788°F)
GT1600 Series
• Configurable to retro-fit GT1000, GT130x and Full-View models
• Premium materials of constructionensure safety, indoor and outdoor durability
• Process connections can be rotated 360°, 180° viewing window, panel or wall mount option
• Transparent scale for easy readability; polycarbonate safety shield for absolute safety
• Monitor critical flow conditions withoptional alarm (purchase at time of order or add it in the field)
• Optional integral inlet or outlet valvesaves space, time & cost, eliminating potential leak points
Durable and accurate for high-pressure and extreme temperature applications
When Petro-Chemical and Refining customers need
high-performance flow meter technology and in-depth technical
expertise, Brooks Instrument is their trusted source for reliable,
accurate solutions.
Our broad line of flow meters, including the MT3750 and MT3809
Series, incorporates key features engineered for tough oil and gas
applications:
• Various process connection types (depending on
base model):
- Threaded - NPT
- Flanged - ANSI, DIN, JIS, API
• Option for high alloys (Inconel 625, Hastelloy C, Titanium)
• Special options for high and low temperature applications
• Special MT3809 design for use in high pressure applications
up to 20,000 psig (1379 bar)
International Approvals
You can be confident using our flow meters for the widest range
of applications and environments. We have earned key industry
approvals that meet most international standards and codes, such
as:
• ATEX
• CCOE
• CE (EMC, RoHS,PED)
• CRN
• CSA
• IECEx
• IP66 / IP67
• KOSHA
• NAMUR
• NEMA 4X
• NEPSI
• SIL-2 on alarms
• TR-CU
• UL
Metal Tube Variable Area Flow Meters
Sho-Rate™ Models 1350,1355, 1358 Glass TubeFlow Meters
GT1600 Series GlassTube Flow Meters
MT3750 Series Metal Tube Flow Meters
MT3809 Series Metal Tube Flow Meters
The industry standard glasstube VA flow meter for decades.Multiple material options availablefor a wide variety of applications.
Simple, rugged design forlong-lasting performance withlow and high-flow gas and liquidapplications where viewing theprocess is important.
Reliable, durable, low flow measurement for long-lasting performance in harsh environments.
Widest temperature, pressure and flow ranges for measuring fluids in hazardous, remote areas.
• Rugged, single piece frameconstruction
• Magnifier built into front shield
• Optional needle valves and flowcontrollers mounted to inlet oroutlet for precision flow control
• Standard direct read scaleson tube for all fluids and fluidconditions
• Standard millimeter scales withflow curves for all fluids and fluidconditions
• 65mm or 150mm scale lengths
• For use in low-flow applications with high-pressure or hazardous fluids
• Compact design
• 4–20 mA output
• Good upgrade from glass tube flow meters
• Optional alarms, transmittersand limit switch controllers provide added levels of measurement and control
• Independent and easilyaccessible diagnostic/service port
• Repeatable flow measurement evenat low process temperatures down to -198°C/-325°F and high process temperatures up to 420°C/788°F
• Designed for high process pressures 1379 bar / 20,000 psig
• Optional local operator interface with LCD screen
• Alarm functions meet SIL 2 requirements
• Multiple corrosion-resistant wetted materials and indicator housings available
• Meets ASME B31.3 standard
• Analog & Digital I/Os: 4-20 mA, HART ® 7, FOUNDATION Fieldbus™
• Fluid Types — clean liquids andgases
• Flow Range —o Air: Up to 15 scfm / 425 slpmo Water: Up to 5 gpm / 19 lpm
• Accuracy — ±3, ±5, ±10% FS
• Max Pressure — 200 psig(13.8 bar)
• Temperature Range — 1–121°C(33- 250°F)
• Fluid Types — clean liquids andgases
• Flow Range —o Air: Up to 150 scfm/270 m3n/h
o Water: Up to 21 gpm/4,800 l/h
• Accuracy — ±2, ±5, ±10% FS Class 2.5acc VDI/VDE, (Optional ±1% FS, Class1.6 acc VDI/VDE)
• Max Pressure — 500 psig(34.5 bar)
• Temperature Range — 1–121°C(33-250°F)
• Fluid Types — clean liquids, gases and steam
• Flow Range —o Air: Up to 110 scfh / 3.1 m3n/ho Water: Up to 26 gpm / 100 l/h
• Accuracy — ±3, ±5% FSo Class 2.5, 4.0 VDI
• Max Pressure — o Standard 1500 psig (100 bar)o Optional 4000 psig (276 bar)
• Temperature Range — -50–204°C (-58-400°F)
• Fluid Types — clean liquids, gases and steam
• Flow Range —o Air: Up to 750 scfm / 1200 m3n/
hro Water: Up to 440 gpm / 100,000
l/h
• Accuracy — ±1, ±2%, ±3%, ±5% FSo Class 1.6, 2.5, 4.0 VDI
• Max Pressure — o Standard 6000 psig (413.7 bar)o Optional 20,000 psig (1379 bar)
• Temperature Range — -198–420°C (-325-788°F)
Global Footprint
All specifications are subject to change without notice. Brooks is a trademark of Brooks Instrument, LLC. All other trademarks are the property of their respective owners.
© Copyright 2019 Brooks Instrument, LLC All rights reserved.
Focused Expertise
As one of the pioneering manufacturers in variable area (VA) flow meter technology, Brooks Instrument has created a diverse and proven portfolio of gas flow meters, installed and in use across virtually every industry. Brooks Instrument has more than 70 years of global flow experience in over 80 countries, with successful applications ranging from nuclear and biotechnology to power and petrochemical.
Our global network of factory trained, certified flow specialists can help you select and configure devices that raise the performance and results of your processes to new levels.
Trust the expertise of the Brooks Instrument team and see why Brooks Instrument leads the world in variable area flow meters.
Also Available Mass Flow Controllers & Meters | Pressure & Vacuum
Fremont, CA(510) 440-1139
Austin, TX(972) 839-3294
Taipei, Taiwan+886 (02) 2719-9358
Global HeadquartersHatield, PA(888) 554-3569
Seoul, Korea+82 (31) 708 2562
Dresden, Germany+49 (0) 351 2152 0417Veenendaal, The Netherlands
+31 318 549 300Székesfehérvár, Hungary
Mumbai, India
Tokyo, Japan+81 3 5633 7100
Tianjin, China
Shanghai, China
+011 36 (22) 539 604
+91 (22) 6627 0780
+86 (21) 5079 8828
+86 139 1871 9630
Visit www.BrooksInstrument.com to locate the facility nearest to you.
● Manufacturing● Service Centers● Application Support & Sales
VA-Ind, 10-19