LEAK STOP / LEAK STOP+Refrigerant Leak Sealant
NC ONE & DONE LEAK STOP is a range of concentrated refrigerant leak sealants supplied with a hose injection delivery system that makes installation of the leak sealant ... simple, fast and easy. The proven formula which is supplied in a clear hose permanently seals microscopic leaks without need to pump down the system ... even for R410A applications. NC ONE & DONE LEAK STOP is available with and without UV dye in two sizes to treat systems up to 1.5 tons; and 1.5 tons to 5 tons.
FEATURES & BENEFITS• Simple to Use … Installs in Seconds … No Additional Tools Needed• Seals Leaks Permanently … Won’t Clog Expansion Valves or Cap Tubes• Ideal for use in split systems, heat pumps, microchannel coils, packaged units, and mini splits.• Safe to Use with all refrigerants and oils• Professional Use Only
DIRECTIONS FOR USE: IMPORTANT: If system moisture levels exceed industry standards (<100ppm for POE oil; <50ppm for min-eral/alkyl benzene) always use NC ONE & DONE A/C DRY or an industry accepted drying agent 20 minutes before installing the leak sealant.
STEP 1. Turn the a/c system on and verify the unit is running. Connect NC ONE & DONE LEAK STOP to the low side service port of the system (this is generally the large line).
STEP 2. Ensure the valves on manifold gauge set are closed. Start by connecting the high side (red) line of manifold gauge set to the high side service port. Remove NC ONE & DONE LEAK STOP from the Mylar bag and loosely connect the middle manifold hose (yel-low) to the 1/4˝ SAE male fitting of the NC ONE & DONE LEAK STOP being careful NOT to depress the Schrader core. Quickly open the high side manifold valve to purge air out of the yellow hose. Now close the high side manifold valve, and quickly tighten the yellow hose fitting to the injector.
STEP 3. Next rapidly open and close the high side valve of the manifold gauge allowing a small amount of liquid to flow through the yellow hose and NC ONE & DONE LEAK STOP tube. With high side valve of the manifold gauge set closed, wait one minute for the yellow hose and NC ONE & DONE LEAK STOP to equalize to suction pressure. Disconnect NC ONE & DONE LEAK STOP from suction service port and from manifold gauge set. Allow unit to run for at least one hour to Ensure product has circulated in the system. Recycle empty container.
WARNING: Do not bend, cut or deform NC ONE & DONE LEAK STOP tube. Be careful not to allow refrigerant to spray on bare skin, as it could cause frostbite.
NC ONE & DONE LEAK STOP (under 1.5 tons) . . . . . . . . .NCLSNC ONE & DONE LEAK STOP (1.5 - 5 tons) . . . . . . . . . . .NCLS5NC ONE & DONE LEAK STOP+ w/UVDYE (under 1.5 tons) . . .NCLSUVNC ONE & DONE LEAK STOP+ w/UVDYE (1.5 - 5 tons) . . . . .NCLSUV5
Refer to product label & Safety Data Sheet for precautionary and First Aid Information. The SDS is available on the NRP website at www.nrproducts.com
National Refrigeration Products985 Wheeler Way
Langhorne, PA 19047 USA - (800) 352-6951
READ INSERT BEFORE USE
Professional Use OnlyPatent Pending
IMPROVED PERFORMANCEIMPROVED PERFORMANCE IMPROVED PERFORMANCE
REFRIGERANT LEAK SEALANT
0.1 net wt. oz.
MORECONCENTRATED
FORMULA
NO PUMP DOWNON R-410ASYSTEMS
NO ADDITIONALTOOLS
REQUIRED
SEALS LEAKSFASTER THAN
OIL-BASED
PART #: NCLS
PART #: NCLS
NC ONE & DONE LEAK STOP is a concentrated refrigerant leak sealant supplied with a patent pending hose injection delivery system that makes installation of the leak sealant... simple, fast and easy. The proven formula which is supplied in a clear hose permanently seals microscopic leaks without need to pump down the system... even for R410A applications.
TREATSSYSTEMS
UNDER
1.5 TONS
NATIONAL REFRIGERATION PRODUCTS 985 Wheeler Way
Langhorne, PA 19047, USAwww.nrproducts.com
Telephone: (800) 352-6951
Quick & EasyInstallation
Seals LeaksPermanently
Seals More Leaks,Seals Larger Leaks
Compatible with All Oils and Refrigerants Except Ammonia
WARNING: This product can expose you to chemicals including Toluene, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
FOR PROFESSIONAL USE ONLYDIRECTIONS FOR USE: STEP 1. Turn the a/c system on and verify the unit is running. Connect NC ONE & DONE LEAK STOP PRO to the low side service port of the system (this is generally the large line).
STEP 2. Ensure the valves on manifold gauge set are closed. Start by connecting the high side (red) line of manifold gauge set to the high side service port. Remove NC ONE & DONE LEAK STOP PRO from the Mylar bag and loosely connect the middle manifold hose (yellow) to the 1/4˝ SAE male �tting of the NC ONE & DONE LEAK STOP PRO being careful NOT to depress the Schrader core. Quickly open the high side manifold valve to purge air out of the yellow hose. Now close the high side manifold valve, and quickly tighten the yellow hose �tting to the injector.STEP 3. Next rapidly open and close the high side valve of the manifold gauge allowing a small amount of liquid to �ow through the yellow hose and NC ONE & DONE LEAK STOP PRO tube. With high side valve of the manifold gauge set closed, wait one minute for the yellow hose NC ONE & DONE LEAK STOP PRO to equalize to suction pressure. Disconnect NC ONE & DONE LEAK STOP PRO from suction service port and from manifold gauge set. Allow unit to run for at least one hour to Ensure product has circulated in the system. Recycle empty container.
NOTE: Use a refrigerant cylinder to push sealant into system while charging if the system is low on refrigerant. Simply connect NC ONE & DONE LEAK STOP PRO to service port and inject refrigerant through injector into system while charging.IMPORTANT: Avoid damage to NC ONE & DONE LEAK STOP PRO tube. Protect skin from refrigerant spray.
IMPORTANT INFORMATION READ BEFORE USE Read and understand the product’s label and Safety Data sheet. DO NOT mix with ammonia. DO NOT use in any manner for which it was not designed. Always wear PPE (Personal Protective Equipment) when servicing HVAC equipment. Causes skin irritation, and/or serious eye irritation. May cause respiratory irritation, drowsiness, and/or dizziness. May cause damage to organs through prolonged or repeated exposure. PREVENTION: Do NOT handle or use this product, until all safety precautions have been read, and understood. Keep away from heat/sparks/open �ame/hot surfaces – NO SMOKING! Wash thoroughly after handling. Use ONLY in well-ventilated areas. Do NOT breathe mist or vapor! Wear protective gloves/protective clothing/eye and face protection. FIRST AID MEASURES: Inhalation: If symptoms occur: go into open air and ventilate suspected area. Call a doctor/physician if symptoms persist. Skin Contact: Wash thoroughly and if symptoms persist, seek medical attention. Eye Contact: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor/physi-cian. Ingestion: Do not induce vomiting. Immediately call a POISON CENTER or doctor/physician. IN CASE OF FIRE: Use dry chemical powder, alcohol-resistant foam or carbon dioxide. STORAGE: Keep temperatures below 52°C/125°F. Store in a dry/cool/well-ventilated place. Store locked up. Incompatible products: Heat sources, and oxidizers. DISPOSAL: Dispose of contents in accordance with local/regional/national/ international regulations.Contains: Ethyl Alcohol (64-17-5), Toluene (108-88-3), Silane, Ethenyltriethoxy (78-08-0).
DANGER
WARNING: This product can expose you to chemicals including Toluene, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
READ INSERT BEFORE USE
Professional Use OnlyPatent Pending
IMPROVED PERFORMANCEIMPROVED PERFORMANCE IMPROVED PERFORMANCE
0.1 net wt. oz.
MORECONCENTRATED
FORMULA
NO PUMP DOWNON R-410ASYSTEMS
NO ADDITIONALTOOLS
REQUIRED
SEALS LEAKSFASTER THAN
OIL-BASED
PART #: NCLSUV
PART #: NCLSUV
NC ONE & DONE LEAK STOP+ W/UV DYE is a concentrated refrigerant leak sealant supplied with a patent pending hose injection delivery system that makes installation of the leak sealant... simple, fast and easy. The proven formula which is supplied in a clear hose permanently seals microscopic leaks without need to pump down the system... even for R410A applications.
TREATSSYSTEMS
UNDER
1.5 TONS
NATIONAL REFRIGERATION PRODUCTS 985 Wheeler Way
Langhorne, PA 19047, USAwww.nrproducts.com
Telephone: (800) 352-6951
Quick & EasyInstallation
Seals LeaksPermanently
Seals More Leaks,Seals Larger Leaks
Compatible with All Oils and Refrigerants Except Ammonia
REFRIGERANT LEAK SEALANT
WITH
UV
WITH
UV
WITH
UV
FOR PROFESSIONAL USE ONLYDIRECTIONS FOR USE: STEP 1. Turn the a/c system on and verify the unit is running. Connect NC ONE & DONE LEAK STOP+ WITH UV to the low side service port of the system (this is generally the large line).
STEP 2. Ensure the valves on manifold gauge set are closed. Start by connecting the high side (red) line of manifold gauge set to the high side service port. Remove NC ONE & DONE LEAK STOP+ WITH UV from the Mylar bag and loosely connect the middle manifold hose (yellow) to the 1/4" SAE male �tting of the NC ONE & DONE LEAK STOP+ WITH UV being careful NOT to depress the Schrader core. Quickly open the high side manifold valve to purge air out of the yellow hose. Now close the high side manifold valve, and quickly tighten the yellow hose �tting to the injector. STEP 3. Next rapidly open and close the high side valve of the manifold gauge allowing a small amount of liquid to ¡ow through the yellow hose and NC ONE & DONE LEAK STOP+ WITH UV tube. With high side valve of the manifold gauge set closed, wait one minute for the yellow hose and NC ONE & DONE LEAK STOP+ WITH UV to equalize to suction pressure. Disconnect NC ONE & DONE LEAK STOP+ WITH UV from suction service port and from manifold gauge set. Allow unit to run for at least one hour to Ensure product has circulated in the system. Recycle empty container.
IMPORTANT INFORMATION READ BEFORE USE Read and understand the product's label and Safety Data sheet. DO NOT mix with ammonia. DO NOT use in any manner for which it was not designed. Always wear PPE (Personal Protective Equipment) when servicing HVAC equipment. Causes skin irritation, and/or serious eye irritation. May cause respiratory irritation, drowsiness, and/or dizziness. May cause damage to organs through prolonged or repeated exposure. PREVENTION: Do NOT handle or use this product, until all safety precautions have been read, and understood. Keep away from heat/sparks/open ¡ame/hot surfaces - NO SMOKING! Wash thoroughly after handling. Use ONLY in well-ventilated areas. Do NOT breathe mist or vapor! Wear protective gloves/protective clothing/eye and face protection. FIRST AID MEASURES: Inhalation: If symptoms occur: go into open air and ventilate suspected area. Call a doctor/physician if symptoms persist. Skin Contact: Wash thoroughly and if symptoms persist, seek medical attention. Eye Contact: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor/physi-cian. Ingestion: Do not induce vomiting. Immediately call a POISON CENTER or doctor/physician. IN CASE OF FIRE: Use dry chemical powder, alcohol-resistant foam or carbon dioxide. STORAGE: Keep temperatures below 52°C/125°F. Store in a dry/cool/well-ventilated place. Store locked up. Incompatible products: Heat sources, and oxidizers. DISPOSAL: Dispose of contents in accordance with local/regional/national/ international regulations. Contains: Ethyl Alcohol (64-17-5), Toluene (108-88-3), Silane, Ethenyltriethoxy (78-08-0).
DANGER
READ INSERT BEFORE USE
Professional Use OnlyPatent Pending
IMPROVED PERFORMANCEIMPROVED PERFORMANCE IMPROVED PERFORMANCE
REFRIGERANT LEAK SEALANT
0.1 net wt. oz.
MORECONCENTRATED
FORMULA
NO PUMP DOWNON R-410ASYSTEMS
NO ADDITIONALTOOLS
REQUIRED
SEALS LEAKSFASTER THAN
OIL-BASED
PART #: NCLS5
PART #: NCLS5
Quick & EasyInstallation
Seals LeaksPermanently
Seals More Leaks,Seals Larger Leaks
Compatible with All Oils and Refrigerants Except Ammonia
NATIONAL REFRIGERATION PRODUCTS 985 Wheeler Way
Langhorne, PA 19047, USAwww.nrproducts.com
Telephone: (800) 352-6951
TREATSSYSTEMS
1.5TO 5 TONS
WARNING: This product can expose you to chemicals including Toluene, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
NC ONE & DONE LEAK STOP is a concentrated refrigerant leak sealant supplied with a patent pending hose injection delivery system that makes installation of the leak sealant... simple, fast and easy. The proven formula which is supplied in a clear hose permanently seals microscopic leaks without need to pump down the system... even for R410A applications.
FOR PROFESSIONAL USE ONLYDIRECTIONS FOR USE: STEP 1. Turn the a/c system on and verify the unit is running. Connect NC ONE & DONE LEAK STOP PRO to the low side service port of the system (this is generally the large line).
STEP 2. Ensure the valves on manifold gauge set are closed. Start by connecting the high side (red) line of manifold gauge set to the high side service port. Remove NC ONE & DONE LEAK STOP PRO from the Mylar bag and loosely connect the middle manifold hose (yellow) to the 1/4˝ SAE male �tting of the NC ONE & DONE LEAK STOP PRO being careful NOT to depress the Schrader core. Quickly open the high side manifold valve to purge air out of the yellow hose. Now close the high side manifold valve, and quickly tighten the yellow hose �tting to the injector.STEP 3. Next rapidly open and close the high side valve of the manifold gauge allowing a small amount of liquid to �ow through the yellow hose and NC ONE & DONE LEAK STOP PRO tube. With high side valve of the manifold gauge set closed, wait one minute for the yellow hose NC ONE & DONE LEAK STOP PRO to equalize to suction pressure. Disconnect NC ONE & DONE LEAK STOP PRO from suction service port and from manifold gauge set. Allow unit to run for at least one hour to Ensure product has circulated in the system. Recycle empty container.
NOTE: Use a refrigerant cylinder to push sealant into system while charging if the system is low on refrigerant. Simply connect NC ONE & DONE LEAK STOP PRO to service port and inject refrigerant through injector into system while charging.IMPORTANT: Avoid damage to NC ONE & DONE LEAK STOP PRO tube. Protect skin from refrigerant spray.
IMPORTANT INFORMATION READ BEFORE USE Read and understand the product’s label and Safety Data sheet. DO NOT mix with ammonia. DO NOT use in any manner for which it was not designed. Always wear PPE (Personal Protective Equipment) when servicing HVAC equipment. Causes skin irritation, and/or serious eye irritation. May cause respiratory irritation, drowsiness, and/or dizziness. May cause damage to organs through prolonged or repeated exposure. PREVENTION: Do NOT handle or use this product, until all safety precautions have been read, and understood. Keep away from heat/sparks/open �ame/hot surfaces – NO SMOKING! Wash thoroughly after handling. Use ONLY in well-ventilated areas. Do NOT breathe mist or vapor! Wear protective gloves/protective clothing/eye and face protection. FIRST AID MEASURES: Inhalation: If symptoms occur: go into open air and ventilate suspected area. Call a doctor/physician if symptoms persist. Skin Contact: Wash thoroughly and if symptoms persist, seek medical attention. Eye Contact: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor/physi-cian. Ingestion: Do not induce vomiting. Immediately call a POISON CENTER or doctor/physician. IN CASE OF FIRE: Use dry chemical powder, alcohol-resistant foam or carbon dioxide. STORAGE: Keep temperatures below 52°C/125°F. Store in a dry/cool/well-ventilated place. Store locked up. Incompatible products: Heat sources, and oxidizers. DISPOSAL: Dispose of contents in accordance with local/regional/national/ international regulations.Contains: Ethyl Alcohol (64-17-5), Toluene (108-88-3), Silane, Ethenyltriethoxy (78-08-0).
DANGER
READ INSERT BEFORE USE
Professional Use OnlyPatent Pending
IMPROVED PERFORMANCEIMPROVED PERFORMANCE IMPROVED PERFORMANCE
REFRIGERANT LEAK SEALANT
0.1 net wt. oz.
MORECONCENTRATED
FORMULA
NO PUMP DOWNON R-410ASYSTEMS
NO ADDITIONALTOOLS
REQUIRED
SEALS LEAKSFASTER THAN
OIL-BASED
PART #: NCLSUV5
PART #: NCLSUV5
Quick & EasyInstallation
Seals LeaksPermanently
Seals More Leaks,Seals Larger Leaks
Compatible with All Oils and Refrigerants Except Ammonia
NC ONE & DONE LEAK STOP+ W/UV DYE is a concentrated refrigerant leak sealant supplied with a patent pending hose injection delivery system that makes installation of the leak sealant... simple, fast and easy. The proven formula which is supplied in a clear hose permanently seals microscopic leaks without need to pump down the system... even for R410A applications.
NATIONAL REFRIGERATION PRODUCTS 985 Wheeler Way
Langhorne, PA 19047, USAwww.nrproducts.com
Telephone: (800) 352-6951
TREATSSYSTEMS
1.5TO 5 TONS
WITH
UV
WITH
UV
WITH
UV
WARNING: This product can expose you to chemicals including Toluene, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
FOR PROFESSIONAL USE ONLYDIRECTIONS FOR USE: STEP 1. Turn the a/c system on and verify the unit is running. Connect NC ONE & DONE LEAK STOP+ WITH UV to the low side service port of the system (this is generally the large line).
STEP 2. Ensure the valves on manifold gauge set are closed. Start by connecting the high side (red) line of manifold gauge set to the high side service port. Remove NC ONE & DONE LEAK STOP+ WITH UV from the Mylar bag and loosely connect the middle manifold hose (yellow) to the 1/4" SAE male �tting of the NC ONE & DONE LEAK STOP+ WITH UV being careful NOT to depress the Schrader core. Quickly open the high side manifold valve to purge air out of the yellow hose. Now close the high side manifold valve, and quickly tighten the yellow hose �tting to the injector. STEP 3. Next rapidly open and close the high side valve of the manifold gauge allowing a small amount of liquid to ¡ow through the yellow hose and NC ONE & DONE LEAK STOP+ WITH UV tube. With high side valve of the manifold gauge set closed, wait one minute for the yellow hose and NC ONE & DONE LEAK STOP+ WITH UV to equalize to suction pressure. Disconnect NC ONE & DONE LEAK STOP+ WITH UV from suction service port and from manifold gauge set. Allow unit to run for at least one hour to Ensure product has circulated in the system. Recycle empty container.
IMPORTANT INFORMATION READ BEFORE USE Read and understand the product's label and Safety Data sheet. DO NOT mix with ammonia. DO NOT use in any manner for which it was not designed. Always wear PPE (Personal Protective Equipment) when servicing HVAC equipment. Causes skin irritation, and/or serious eye irritation. May cause respiratory irritation, drowsiness, and/or dizziness. May cause damage to organs through prolonged or repeated exposure. PREVENTION: Do NOT handle or use this product, until all safety precautions have been read, and understood. Keep away from heat/sparks/open ¡ame/hot surfaces - NO SMOKING! Wash thoroughly after handling. Use ONLY in well-ventilated areas. Do NOT breathe mist or vapor! Wear protective gloves/protective clothing/eye and face protection. FIRST AID MEASURES: Inhalation: If symptoms occur: go into open air and ventilate suspected area. Call a doctor/physician if symptoms persist. Skin Contact: Wash thoroughly and if symptoms persist, seek medical attention. Eye Contact: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor/physi-cian. Ingestion: Do not induce vomiting. Immediately call a POISON CENTER or doctor/physician. IN CASE OF FIRE: Use dry chemical powder, alcohol-resistant foam or carbon dioxide. STORAGE: Keep temperatures below 52°C/125°F. Store in a dry/cool/well-ventilated place. Store locked up. Incompatible products: Heat sources, and oxidizers. DISPOSAL: Dispose of contents in accordance with local/regional/national/ international regulations. Contains: Ethyl Alcohol (64-17-5), Toluene (108-88-3), Silane, Ethenyltriethoxy (78-08-0).
DANGER
(Packed 6 hoses per pack)