A FAct-BAsed Guide on Moisture VApor protection
reducinG Moisture VApor eMissions in concrete construction
-
2
Moisture VApor eMissionsprotect Your FloorinG inVestMent FroM
Moisture vapor is a hot topic in any type of construction where you have concrete on, above, or below grade. Moisture vapor emissions through a concrete slab in any building can contribute to costly floor good failures, down time, and slow construction schedules.
over the past 20 years, the frequency of moisture vapor emission issues has increased. several contributing factors include: •Thelossofasbestosasaningredientinresilientflooring •Thelossofsolventsfromadhesiveandcoatingsystems •Increaseduseofwaterforeasierplacementofstructural
and lightweight concrete •Fasttrackconstructionschedules
HighpH(alkalinity)canbeextremelydetrimentaltolatex-basedadhesivesas well. Moisture vapor moving through the concrete to the surface will accumulate at the bond line between adhered flooring material and the concrete. the combination of moisture and salts present in the concrete combine to create a high pH environment. the high pH condensate begins tobreakdownthewater-basedadhesive,resultinginafloorgoodfailure.
-
3
Moisture MitiGAtion sYsteMensurinG An eFFectiVe
in order to address the prevalence of floor good failures relating to inadequate moisture vapor barriers, AstM committee F06 on resilient Floor coverings developed and approved AstM F3010-13 – “standard practice for two-component resin Based Membrane-Forming Moisture Mitigation systems for use under resilient Floor coverings”.
this new standard applies specifically to two-component, resin-based moisture mitigation systems. it discusses the application of these moisture vapor barriers over concrete floors with high moisture content. AstM F3010-13 also discusses the properties and performance requirements of these products prior to installation of resilient floor coverings.
in order to meet AstM F3010-13 these products need to meet the following criteria: 1. reduce moisture transmission to no more than 0.1 perm. 2. Must define perm as grains/hr/ft2/in•Hg. 3.Manufacturermustspecifymilthicknessrequiredtomeetthe
0.1 perm rating. 4. products must be tested in accordance with AstM e96.
AstM F3010-13 does not cover the following membrane-forming and non-membrane-forming moisture mitigation systems: •Systemsthatchemicallyreactwithanycomponentoftheconcrete
forming a gel or crystalline substance within the concrete •Penetrating,water-orsolvent-basedcompoundsformingadiscontinuous
membrane on the concrete surface •Water-basedmembrane-formingsystems
Gym floor failure due to moisture vapor emissions.treatment with surface applied moisture vapor barrier will help protect the new gym floor.
-
4
BELOW-SLABBARRIERS
BreAcHABle
delAYed VApor releAse
does not Address pH leVels
precipitAtion resets drYinG tiMe
Rocks,shoes,wire,rebar,heavyequipment,etc.cancausetearsandholes, compromising the barrier.
Whilethebelow-slabsystempreventsgroundmoisturefromcomingthrough the slab, this system does nothing to reduce moisture vapor emissions from new concrete which often releases moisture months after installation.
Because the barrier is under the slab, it does nothing to address pH levels in the concrete itself.
Concreteslabstakeapproximately30daysper1"ofconcreteunderideal conditions to reach acceptable moisture levels for installation of floor goods.Iftheslabisfurtherexposedtoprecipitation,theclockresets.
concrete slab on or Below Grade
under slab Vapor Barrier
-
5
surFAce-Applied Moisture VApor BArriers
coMplete coVerAGe
reduces Moisture VApor FroM All MAteriAls
proVides A pH BArrier
VeriFied independent testinG
cannot be torn, resulting in complete, durable coverage.
Because the barrier is applied to the top of the concrete, it stops moisture vapor emissions from concrete, ground and environmental conditions.
NotaffectedbypHanddoesnotallowalkalinestoconcentrateatthe new bond layer.
Meets AstM F3010, which requires a perm rating of no greater than 0.1 grains/hr/ft2/in•Hg.Verifymanufacturer’srequiredmilthicknesstoachieve perm rating.
concrete
surface Applied Moisture Vapor Barrier
-
6
penetrAnt/silicAte
BreAtHABle
AdHesiVe MAnuFActurers require reMoVAl
ONLyLOWERSpHASSOCIATEdWITHCALCIuMHydROxIdE
liMited independent testinG
not speciFicAllY desiGned For tHis ApplicAtion
Allows moisture to penetrate slab.
Adhesives will not bond to penetrants/silicates.
pHlevelsassociatedwithsodiumhydroxideandpotassiumhydroxideremain.
Originallydesignedforexposedconcrete,moisturevaporemissionsis secondary use.
does not meet AstM F3010 perm rating. AstM F3010 now requires a perm rating of no greater than 0.1 grains/hr/ft2/in•Hg(0.1perm).
concrete
penetrant/silicate
-
7
surFAce-Applied Moisture VApor BArriers
HiGHest Moisture VApor reduction cApABilities
eAsilY Applied
Best resistAnce to AlkAlinitY up to pH 14
VeriFied independent testinG
can reduce MVer rates of up to 25 lbs to 3 lbs or less, tested using a calcium chloride test.
installation is permanent and application on most jobs is finished within a few hours.
offers protection from the high pH levels associated with moisture vapor emissions associated with adhesive failures.
Meets AstM F3010, which requires a perm rating of no greater than 0.1 grains/hr/ft2/in•Hg.Verifymanufacturer’srequiredmilthicknesstoachieve perm rating.
concrete
surface Applied Moisture Vapor Barrier
ForMulAtions desiGned For Moisture MitiGAtion
product was developed for the application, resulting in greater success.
-
8
dispersiVe MeMBrAnes
not conduciVe to HeAVY trAFFic
POTENTIALFORBACTERIALgROWTH
VerY little independent testinG
Adds tHickness to tHe Floor
Theflexiblenatureofthematslimitsfloorgoodchoices.
since the mats are pliable, they cannot withstand heavy traffic/point loads.
Moisture can condense on organic material left on the concrete presenting the potential for bacterial growth.
chemical reactions between moisture and elements in concrete create high pH environments.
Thissystemaddsthicknesstothefloorbeforeanyfloorgoodsareinstalled.
concrete
dispersive Membrane
MediuM pH resistAnce
does not meet AstM F3010 perm rating. AstM F3010 now requires a perm rating of no greater than 0.1 grains/hr/ft2/in•Hg(0.1perm).
MATSCANONLyBEuSEdWITHCERTAINFLOORINgSySTEMS
-
9
surFAce-Applied Moisture VApor BArriers
FORuSEWITHANyFLOORgOOdS
CANWITHSTANdHEAVyTRAFFIC
NOPOTENTIALFORBACTERIALgROWTH
Best resistAnce to AlkAlinitY up to pH 14
VeriFied independent testinG
no Added Floor HeiGHt
design possibilities are not limited by flooring compatibility when paired with an underlayment system.
A solid surface that can withstand most traffic.
Materials provide no source for bacterial growth.
offers protection from the high pH levels associated with adhesive failures due to moisture vapor emissions.
Meets AstM F3010, which requires a perm rating of no greater than 0.1 grains/hr/ft2/in•Hg.Verifymanufacturer’srequiredmilthicknesstoachieve perm rating.
Surfaceappliedmoisturevaporbarriersdonotaddthicknesstotheoverallfloor height.
concrete
surface Applied Moisture Vapor Barrier
concrete
-
10
deHuMidiFicAtionMoisture
released through dehumidification commercial
dehumidifier
concrete
onlY Addresses Moisture in tHe top oF tHe slAB
MAY or MAY not Be successFul
no predeterMined scHedule
NOExTENdEdWARRANTy
CANNOTBEuSEdONNEWCONCRETE
Moisturecanexistthroughoutslab,notonlythetop.
Thereisnotestdata/guaranteeitwillworkasapermanentsolution.
Noideahowlongmoisturereductionprocesscantake.
since it only addresses the symptom, not the source, moisture may reappear.
Acceleratesdryingwhichcancausecracking,curlingandphysical property loss.
-
11
surFAce-Applied Moisture VApor BArriers
concrete
surface Applied Moisture Vapor Barrier
concrete
commercial dehumidifier
MitiGAtes Moisture VApor eMissions
proVen solution
scHeduled proGrAM
WARRANTIEdSySTEM
NEWOROLdCONSTRuCTION
since it creates a barrier, moisture vapor emissions are reduced significantly.
proven on projects with a variety of applications throughout north America andbackedbyindependentlabtesting.
Constructionschedulesstayontrackwithaninstallationschedule.
Backedbymanufacturer’swarranty.
can be used in new construction, including 5 days after concrete installation.
-
12
Moisture MitiGAtion SOLuTIONSFROMMAxxON
Maxxon®CorporationnowoffersMaxxon®dPM(dampProofMembrane)andMaxxon®MVP(MoistureVaporProtection),surfaceappliedmoisturevapor barriers that prevent the passage of moisture vapor through slabs on, below or above grade.
MaxxondPMandMaxxonMVPreducemoisturevaporemissionsofupto25lbs.to3lbs.orlessandprovideahighalkalinitybarrier(uptopH14),preventing the delamination of adhesives, floor coverings and coatings. MaxxondPMalsopreventscapillaryinfiltrationofoilorotherchemicalsfrom the ground and can be used to treat oil contaminated slabs.
MaxxondPMandMaxxonMVPinstallquicklyandarereadytoreceiveanapprovedMaxxonunderlaymentthedayafterinstallation.Idealforoldbuildings without a vapor barrier or new buildings, covering even five-day-old concrete:
WhenMaxxondPM/MaxxonMVPistoppedwithaMaxxonunderlayment,* the system offers a single source warranty — our assurance toyouthatintheunlikelyeventissuesshouldarise,wewillstandbehindthe entire system.
*Mustbeinstalledtorequiredmilthicknessaccordingtomanufacturer’srecommendedyieldnecessarytomeetASTMF3010permrating.
•Industrial/retailfacilities•Hospitalsandschools•gymfloors
•Officebuildings•Residentialslabs•Foodprocessingplants